This is a Bid/Permit Set structural drawing package for the Pocono Township Municipal Complex Police Wing renovation project located at Old Mill Road, Tannersville, Pennsylvania, prepared by Kimmel Bogrette Architecture + Site, Inc. The project involves construction of a new sally port structure and associated site work at the existing police facility. The sealed bid submission deadline is November 12 at 1:00 PM through PennBid, with bids to be reviewed privately and made public by 4:00 PM the same day. A mandatory pre-bid conference will be held on October 14 at 10:00 AM at the Pocono Township Administration Building, followed by a site tour. Bid documents are available for download starting October 7 at 9:00 AM through PennBid. The project is divided into four separate construction contracts: General Construction, Mechanical Construction, Electrical Construction, and Plumbing Construction. The structural drawings establish design criteria including a basic wind speed of 125 MPH, ground snow load of 50 PSF, flat roof snow load of 42 PSF, and seismic design category C. No specific contract term is indicated in this permit set document.
Bid security must accompany all bids in the amount of 10% of the Base Bid, in the form of certified check, bank cashier's check, letter of credit, or bid bond from a corporate surety authorized to do business in Pennsylvania. The project is subject to prevailing wage requirements under the Pennsylvania Prevailing Wage Act, the Steel Products Procurement Act limiting steel product usage, and the Reciprocal Limitations Act. The structural design documents specify detailed requirements for materials including structural steel conforming to AISC standards (ASTM A992 for rolled shapes at 50 KSI minimum), concrete construction per ACI 318, masonry construction with CMU units and Type S mortar, and metal deck systems. Special inspections are required for concrete construction, structural steel fabrication and erection, and masonry construction, with all reports to be submitted to the architect by a licensed professional engineer. No additional funding sources or incumbent contractor information are specified in this permit set documentation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 5-Pocono Twp Vol 1 Specs Arch.pdf | ||
| 8-00 53 10 NON COLLUSION.docx | DOCX document | |
| 7-01 - 09.30.2026 Pocono Twp Arch Bid-Permit.pdf | ||
| 13-Addendum 2.pdf | ||
| 4-Pocono Twp Vol 2 Specs MEP.pdf | ||
| 11-Pre-Bid Conference Attendees.pdf | ||
| 1-24.0112 HVAC BID PERMIT 20260930.pdf | ||
| 12-Addendum 1.pdf | ||
| 9-00 53 20 - Waiver of Liens.doc | DOC document | |
| 2-24.0112 PLUMB BID PERMIT 20260930.pdf | ||
| 6-24.0112 ELEC BID PERMIT 20260930.pdf | ||
| 10-00 41 00 - Bid Document Checklist.docx | DOCX document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S0.1
G E N
E R
A L N
O T
E S
.2
4.
Pr og re ss
P rin ts
0%
S
ET
R ev is io ns
C he ck ed
B y:
D ra w n
By
C on st ru ct io n Is su e
D at e:
Sc al e:
A
S N
O
TE
D
N or ris to w n
R oa d, S ui te
B lu e
Be ll, P A
Ph on e:
.8
.7
Fa cs im ile : 6
.8
.7
C O
PY
R
IG
H
T
K
IM
M
EL
B
O G
R
ET
TE
A
R C
H
IT
EC
TU
R E
S
IT
E, I N
C
AL
L
R
IG
H
TS
R
ES
ER
VE
D
A r c h i t e c t u r e
S i t e c
PO
C
O N
O T
O W
N
SH
IP
M
U N
IC
IP
AL
C
O M
PL
EX
N C
C B
U
IL
D
IN
G O
LD
M
IL
L
R O
AD
TA
N
N
ER
SV
IL
LE
P
A
C
L BA
M
.3 0.
BI
D / P
ER
M
IT
S
ET
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
GENERAL INFORMATION
AutoCAD SHX Text
1. "LOADS" INDICATED ON THIS DRAWING ARE THOSE FOR THE DESIGN OF THE BUILDING SUPERSTRUCTURE. "LOADS" INDICATED ON THIS DRAWING ARE THOSE FOR THE DESIGN OF THE BUILDING SUPERSTRUCTURE. 2. DESIGN LOADS AND CRITERIA USED IN THE DESIGN OF SPECIALTY STRUCTURAL SYSTEMS (i.e. CURTAIN- DESIGN LOADS AND CRITERIA USED IN THE DESIGN OF SPECIALTY STRUCTURAL SYSTEMS (i.e. CURTAIN- WALL, FIRESTAIRS, LIGHT GAGE STEEL STUDS, ARCHITECTURAL PRECAST CONCRETE, METAL PANELS, ETC.) TO BE DETERMINED BY A THIRD PARTY ENGINEER CONTRACTED BY THE SPECIALTY STRUCTURAL SYSTEM MANUFACTURER IN ACCORDANCE WITH CODE REQUIREMENTS OF GOVERNING JURISDICTION. SPECIALTY ENGINEER IS RESPONSIBLE FOR ALL CONNECTIONS OF THESE SYSTEMS TO THE SUPERSTRUCTURE, INCLUDING, BUT NOT LIMITED TO, ENGINEERING, DETAILING, AND INSTALLATION. IF ALTERATION TO THE SUPERSTRUCTURE ARE REQUIRED AS DETERMINED BY THE E.O.R. TO REINFORCE FOR HIGH CONCENTRATED FORCES APPLIED TO THE SPECIALTY SYSTEM CONNECTION, THE REINFORCEMENT AND COST SHALL BE BORNE BY THE SPECIALTY SUB-CONTRACTOR AND SHALL BE CONSIDERED A PART OF THE SPECIALTY CONNECTION. 3. ALL DETAILS MARKED "TYPICAL" IN THE SET OF STRUCTURAL DRAWINGS SHALL BE APPLIED THROUGHOUT ALL DETAILS MARKED "TYPICAL" IN THE SET OF STRUCTURAL DRAWINGS SHALL BE APPLIED THROUGHOUT THE PROJECT AS REQUIRED TO SATISFY THE REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL COORDINATE REQUIREMENTS FOR QUANTITY AND LOCATION WHERE THE "TYPICAL" DETAILS APPLY. 4. FAILURE ON THE PART OF THE CONTRACTOR TO REVIEW THE DRAWINGS OF OTHER DISCIPLINES (i.e. FAILURE ON THE PART OF THE CONTRACTOR TO REVIEW THE DRAWINGS OF OTHER DISCIPLINES (i.e. ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, ETC.) TOGETHER WITH THE FULL EXTENT OF THE PROJECT SPECIFICATIONS DOES NOT RELIEVE THEM OF THE RESPONSIBILITY TO FURNISH AND INSTALL NOT RELIEVE THEM OF THE RESPONSIBILITY TO FURNISH AND INSTALL RELIEVE THEM OF THE RESPONSIBILITY TO FURNISH AND INSTALL ITEMS THAT ARE PART OF THEIR WORK AS INDICATED BY THE DRAWINGS AND SPECIFICATIONS OF OTHER TRADES. ALL STRUCTURAL TRADE CONTRACTORS AND SUB-CONTRACTORS ARE PROHIBITED FROM EXCLUDING STRUCTURAL WORK FROM THEIR CONTRACT NOT SHOWN IN THE STRUCTURAL DRAWINGS. 5. DRAWINGS ARE NOT ISSUED FOR BID OR CONSTRUCTION UNLESS EXPLICITLY NOTED AS SUCH.DRAWINGS ARE NOT ISSUED FOR BID OR CONSTRUCTION UNLESS EXPLICITLY NOTED AS SUCH.
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
SHORING AND BRACING GENERAL NOTES
AutoCAD SHX Text
1. CONTRACTOR SHALL PROVIDE LAYOUT DRAWINGS AND CALCULATIONS FOR SHORING AND BRACING SYSTEM CONTRACTOR SHALL PROVIDE LAYOUT DRAWINGS AND CALCULATIONS FOR SHORING AND BRACING SYSTEM AND OTHER DATA, AS REQUIRED, PREPARED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE STATE OF NEW YORK. SUBMIT TO ARCHITECT ONE WEEK PRIOR TO THE START OF WORK. 2. SHORING AND BRACING SHALL COMPLY WITH THE LOCAL BUILDING CODE AND ORDINANCES OF THE LOCAL SHORING AND BRACING SHALL COMPLY WITH THE LOCAL BUILDING CODE AND ORDINANCES OF THE LOCAL GOVERNING AUTHORITIES. 3. INSPECTION FOR STRUCTURAL STABILITY SHALL BE PROVIDED BY AN APPROVED LICENSED ENGINEER INSPECTION FOR STRUCTURAL STABILITY SHALL BE PROVIDED BY AN APPROVED LICENSED ENGINEER EMPLOYED BY THE CONTRACTOR, AS REQUIRED BY LOCAL GOVERNING AUTHORITIES. 4. SUBMIT WEEKLY FIELD OBSERVATION REPORTS TO ARCHITECT DURING THE DURATION OF THE SHORING SUBMIT WEEKLY FIELD OBSERVATION REPORTS TO ARCHITECT DURING THE DURATION OF THE SHORING OPERATION. 5. BENCHMARKS ARE TO BE ESTABLISHED BEFORE EXCAVATIONS AND RE-SURVEYED WEEKLY BY A LICENSED BENCHMARKS ARE TO BE ESTABLISHED BEFORE EXCAVATIONS AND RE-SURVEYED WEEKLY BY A LICENSED LAND SURVEYOR EMPLOYED BY THE CONTRACTOR. 6. BRACING SHALL BE LOCATED TO CLEAR NEW CONSTRUCTION AND OTHER PERMANENT WORK. BRACING SHALL BE LOCATED TO CLEAR NEW CONSTRUCTION AND OTHER PERMANENT WORK. 7. MAINTAIN SHORING AND BRACING UNTIL STRUCTURAL ELEMENTS ARE RE-BRACED BY OTHER BRACING OR MAINTAIN SHORING AND BRACING UNTIL STRUCTURAL ELEMENTS ARE RE-BRACED BY OTHER BRACING OR UNTIL PERMANENT CONSTRUCTION IS IN PLACE.
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
POST-INSTALLED ANCHOR GENERAL NOTES
AutoCAD SHX Text
1. EXCEPT WHERE INDICATED ON THE DRAWINGS, POST-INSTALLED ANCHORS SHALL CONSIST OF EXCEPT WHERE INDICATED ON THE DRAWINGS, POST-INSTALLED ANCHORS SHALL CONSIST OF THE FOLLOWING ANCHOR TYPES AS PROVIDED BY HILTI, INC. CONTACT HILTI AT (800) 879-8000 FOR PRODUCT RELATED QUESTIONS. 2. ANCHOR TYPES: ANCHOR TYPES: 2.1. ANCHORAGE TO CONCRETE: ANCHORAGE TO CONCRETE: : - ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE: ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE: -- HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW HIT-Z ROD HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW HIT-Z ROD PER ICC ESR-3187 -- HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT SYSTEM WITH HAS-E THREADED ROD PER ICC ESR-3187 -- HILTI HIT-RE 500 -SD EPOXY ADHESIVE ANCHORING SYSTEM WITH HILTI HIT-RE 500 -SD EPOXY ADHESIVE ANCHORING SYSTEM WITH HAS-E THREADED ROD PER ICC ESR-2322 FOR SLOW CURE APPLICATIONS - MEDIUM DUTY MECHANICAL ANCHORS FOR CRACKED AND UNCRACKED CONCRETE MEDIUM DUTY MECHANICAL ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE: -- HILTI KWIK HUS EZ AND KWIK HUS EX-I SCREW ANCHORS PER ICC HILTI KWIK HUS EZ AND KWIK HUS EX-I SCREW ANCHORS PER ICC ESR-3027. -- HILTI KWIK BOLT-TZ EXPANSION ANCHORS PER ICC ESR-1917 HILTI KWIK BOLT-TZ EXPANSION ANCHORS PER ICC ESR-1917 -- HILTI KWIK BOLT 3 EXPANSION ANCHORS (UNCRACKED CONCRETE ONLY) HILTI KWIK BOLT 3 EXPANSION ANCHORS (UNCRACKED CONCRETE ONLY) PER ISS ESR-2302 - HEAVY DUTY MECHANICAL ANCHORS FOR CRACJED AND UNCRACKED CONCRETE HEAVY DUTY MECHANICAL ANCHORS FOR CRACJED AND UNCRACKED CONCRETE USE: -- HILTI HDA UNDERCUT ANCHORS PER ICC ESR-1546 HILTI HDA UNDERCUT ANCHORS PER ICC ESR-1546 -- HILTI HSL-3 EXPANSION ANCHORS PER ICC ESR-1545 HILTI HSL-3 EXPANSION ANCHORS PER ICC ESR-1545 2.2 REBAR DOWELING INTO CONCRETE: REBAR DOWELING INTO CONCRETE: : - ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE: ADHESIVE ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE: -- HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT HILTI HIT-HY 200 SAFE SET SYSTEM WITH HILTI HOLLOW DRILL BIT SYSTEM WITH CONTINUOUSLY DEFORMED REBAR PER ICC ESR-3187 -- HILTI HIT-RE 500-SD EPOXY ADHESIVE ANCHORING SYSTEM WITH HILTI HIT-RE 500-SD EPOXY ADHESIVE ANCHORING SYSTEM WITH CONTINUOUSLY DEFORMED REBAR PER ICC ESR-2322 2.3 ANCHORAGE TO SOLID-GROUTED/HOLLOW MASONRY: ANCHORAGE TO SOLID-GROUTED/HOLLOW MASONRY: : - ADHESIVE ANCHORS USE: ADHESIVE ANCHORS USE: -- HILTI HILTI HIT-HY 270 MASONRY ADHESIVE ANCHORING SYSTEM. HILTI HILTI HIT-HY 270 MASONRY ADHESIVE ANCHORING SYSTEM. -- STEEL ANCHOR ELEMENT SHALL BE HILTI HAS-E CONTINUOUSLY STEEL ANCHOR ELEMENT SHALL BE HILTI HAS-E CONTINUOUSLY THREADED ROD OR CONTINUOUSLY DEFORMED STEEL REBAR. -- THE APPROPRIATE SIZE SCREEN TUBE SHALL BE USED PER ADHESIVE THE APPROPRIATE SIZE SCREEN TUBE SHALL BE USED PER ADHESIVE MANUFACTURER'S RECOMMENDATION FOR HOLLOW MASONRY CONDITIONS. 3. ANCHOR CAPACITY USED IN DESIGN SHALL BE BASED ON THE TECHNICAL DATA PUBLISHED BY ANCHOR CAPACITY USED IN DESIGN SHALL BE BASED ON THE TECHNICAL DATA PUBLISHED BY HILTI OR SUCH OTHER METHOD AS APPROVED BY THE STRUCTURAL ENGINEER OF RECORD. SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE. CONTRACTOR SHALL PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED HILTI PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY THEIR HAVING AN ICC ESR SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE TEMPERATURE AND INSTALLATION TEMPERATURE. 4. INSTALL ANCHORS PER THE MANUFACTURERS INSTRUCTIONS, AS INCLUDED IN THE ANCHOR INSTALL ANCHORS PER THE MANUFACTURERS INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGING. 5. OVERHEAD ADHESIVE ANCHORS MUST BE INSTALLED USING THE HILTI PROFIS SYSTEM. OVERHEAD ADHESIVE ANCHORS MUST BE INSTALLED USING THE HILTI PROFIS SYSTEM. 6. THE CONTRACTOR SHALL ARRANGE ANCHOR MANUFACTURER'S REPRESENTATIVE TO PROVIDE THE CONTRACTOR SHALL ARRANGE ANCHOR MANUFACTURER'S REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S PERSONNEL WHO WILL INSTALL ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS.
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
SYMBOL KEY/LEGEND
AutoCAD SHX Text
NEW COLUMN LINE
AutoCAD SHX Text
MOMENT CONNECTION
AutoCAD SHX Text INDICATES SPAN OF METAL DECK. DECK SPANS PERPENDICULAR TO FRAMING UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
SECTION NUMBER
AutoCAD SHX Text
SECTION SHEET LOCATION
AutoCAD SHX Text
DROP-IN FRAME FOR OPENING IN ROOF CONSTRUCTION
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text ADJ. ADJUSTMENT ADJUSTMENT ADJ. ALTERNATE ALTERNATE A.B. ANCHOR BOLT ANCHOR BOLT BOT BOTTOM BOTTOM ATTACH. BUILDING BUILDING BM. BEAM BEAM B.R. BRACE BRACE CANT. CANTILEVER CANTILEVER CENTERLINE CENTERLINE CLR. CLEAR CLEAR C.A., CA COLUMN ABOVE COLUMN ABOVE C.B., CB COLUMN BELOW COLUMN BELOW COL. COLUMN COLUMN CONC. CONCRETE CONCRETE CONN. CONNECTION CONNECTION CONT. CONTINUOUS CONTINUOUS DIA., DIAMETER DIAMETER DWG. DRAWING DRAWING EA. EACH EACH E.F. EACH FACE EACH FACE EL., ELEV. ELEVATION ELEVATION E.O.D. EDGE OF DECK EDGE OF DECK E.O.S. EDGE OF SLAB EDGE OF SLAB EQ. EQUAL, EQUALLY EQUAL, EQUALLY E.W. EACH WAY EACH WAY E.J. EXPANSION JOINT EXPANSION JOINT EXT. EXTENSION EXTENSION FIN. FINISH FINISH FT. FOOT/FEET FOOT/FEET FTG. FOOTING FOOTING H. HANGERHANGER
AutoCAD SHX Text H.P. HIGH POINT HIGH POINT HOR., HORIZ. HORIZONTAL HORIZONTAL H.S.B. HIGH STRENGTH BOLT HIGH STRENGTH BOLT IN. INCHES INCHES JT. JOINT JOINT L.L.H., LLH LONG LEG HORIZONTAL LONG LEG HORIZONTAL L.L.V., LLV LONG LEG VERTICAL LONG LEG VERTICAL L.P. LOW POINT LOW POINT LOC'N(S) LOCATION(S) LOCATION(S) MAX. MAXIMUM MAXIMUM MIN. MINIMUM MINIMUM NO. # NUMBER NUMBER N.T.S. NOT TO SCALE NOT TO SCALE O.C. ON-CENTER ON-CENTER P.S.F., PSF POUNDS PER SQUARE FOOT POUNDS PER SQUARE FOOT P.S.I., PSI POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH R.D. ROOF DRAIN ROOF DRAIN FTG. REINFORCING/REINFORCED REINFORCING/REINFORCED REQ'D REQUIRED REQUIRED S.C. SLIP CONNECTION SLIP CONNECTION S.O.B. SLAB-ON-GRADE SLAB-ON-GRADE SPL. SPLICE SPLICE SPA. SPACE, SPACING SPACE, SPACING SQ. SQUARE SQUARE T & B TOP AND BOTTOM TOP AND BOTTOM SYM. THICKNESS THICKNESS T.O.S. TOP OF STEEL TOP OF STEEL TYP. TYPICAL TYPICAL U.O.N. UNLESS OTHERWISE NOTED UNLESS OTHERWISE NOTED VERT. VERTICAL VERTICAL W.W.F. WELDED WIRE FABRIC WELDED WIRE FABRIC
AutoCAD SHX Text
1. DIMENSIONS AND ELEVATIONS OF EXISTING CONDITIONS GIVEN ON STRUCTURAL DRAWINGS ARE DIMENSIONS AND ELEVATIONS OF EXISTING CONDITIONS GIVEN ON STRUCTURAL DRAWINGS ARE BASED ON LIMITED FIELD OBSERVATIONS AND MEASUREMENTS. 2. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS BY ACTUAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS BY ACTUAL MEASUREMENT. PRIOR TO BEGINNING WORK, AND WHEN FEASIBLE, PRIOR TO SHOP DRAWING SUBMITTALS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO COORDINATE SAID DISCREPANCIES WITH ALL SUB-CONTRACTORS AND MATERIAL SUPPLIERS. 3. CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING AND MAKE SAFE ALL CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING AND MAKE SAFE ALL FLOORS AND/OR ADJACENT PROPERTY AS PROJECT CONDITIONS REQUIRE. DESIGN SHALL BE CERTIFIED BY A LICENSED ENGINEER EMPLOYED BY THE CONTRACTOR. 4. STRUCTURAL ELEMENTS WHICH ARE UNCOVERED DURING THE COURSE OF THE REHABILITATION, STRUCTURAL ELEMENTS WHICH ARE UNCOVERED DURING THE COURSE OF THE REHABILITATION, AN WHICH ARE FOUND TO BE UNSOUND OR DEFICIENT, SHALL BE REINFORCED, SUPPORTED OR REPLACED IN ACCORDANCE WITH THE STRUCTURAL DESIGN CRITERIA OF THE BUILDING SUBCODE.
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
EXISTING CONDITIONS GENERAL NOTES
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
STRUCTURAL STEEL GENERAL NOTES
AutoCAD SHX Text
1. STRUCTURAL STEEL SHALL CONFORM TO THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) STRUCTURAL STEEL SHALL CONFORM TO THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) STEEL CONSTRUCTION MANUAL AND THE SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (2010). 2. UNLESS OTHERWISE NOTED, ALL MATERIALS SHALL BE IN ACCORDANCE WITH THE FOLLOWING UNLESS OTHERWISE NOTED, ALL MATERIALS SHALL BE IN ACCORDANCE WITH THE FOLLOWING SPECIFICATIONS: MEMBER ASTM MINIMUM STRENGTH MEMBER ASTM MINIMUM STRENGTH ASTM MINIMUM STRENGTH MINIMUM STRENGTH ROLLED SHAPES A992 50 KSI A992 50 KSI 50 KSI OTHER ROLLED PLATES A36 36 KSI A36 36 KSI 36 KSI STRUCTURAL TUBING A500 (GRADE B) 46 KSI A500 (GRADE B) 46 KSI 46 KSI STEEL PIPE A500 (GRADE B) 42 KSI A500 (GRADE B) 42 KSI 42 KSI CONNECTION BOLTS A325 92 KSI A325 92 KSI 92 KSI ANCHOR BOLTS F1554 ---- F1554 ---- ---- THREADED RODS A36 36 KSI A36 36 KSI 36 KSI NON-SHRINK GROUT C1107 8,000 PSI C1107 8,000 PSI 8,000 PSI 3. CONNECTIONS SHALL BE SHEAR TYPE CONNECTIONS AND DESIGNED BY THE FABRICATOR IN CONNECTIONS SHALL BE SHEAR TYPE CONNECTIONS AND DESIGNED BY THE FABRICATOR IN ACCORDANCE WITH THE AISC FOURTEENTH EDITION SPECIFICATIONS. MINIMUM BOLT DIAMETER SHALL BE 3/4" UNLESS OTHERWISE NOTED. BOLTS SHALL BE SHEAR/BEARING TYPE BOLTS AND BE "SNUG-TIGHT". STEEL BEAM CONNECTIONS SHALL BE DESIGNED TO SUPPORT A MINIMUM OF ONE HALF THE MAXIMUM TOTAL UNIFORM LOAD FOR PARTICULAR BEAM AND SPAN CONDITION AS DEFINED BY THE AISC MANUAL OF STEEL CONSTRUCTION. 4. METAL DECK SHALL BE ATTACHED ACCORDING TO METAL DECK MANUFACTURER AND STEEL DECK METAL DECK SHALL BE ATTACHED ACCORDING TO METAL DECK MANUFACTURER AND STEEL DECK INSTITUTE (SDI) STANDARDS. 5. WELDING SHALL BE IN ACCORDANCE WITH AMERICAN WELDING SOCIETY (AWS) SPECIFICATION D1.1 WELDING SHALL BE IN ACCORDANCE WITH AMERICAN WELDING SOCIETY (AWS) SPECIFICATION D1.1 USING E7OXX ELECTRODES. UNLESS OTHERWISE NOTED, PROVIDE CONTINUOUS MINIMUM SIZED FILLET WELDS PER AISC REQUIREMENTS. FILLER MATERIALS SHALL HAVE A MINIMUM YIELD STRENGTH OF 58 KSI. 6. HOLES IN STEEL BEAMS SHALL BE DRILLED OR PUNCHED. ALL SLOTTED HOLES SHALL BE PROVIDED HOLES IN STEEL BEAMS SHALL BE DRILLED OR PUNCHED. ALL SLOTTED HOLES SHALL BE PROVIDED WITH SMOOTH EDGES. BURNING OF HOLES AND TORCH CUTTING AT THE SITE IS NOT PERMITTED. 7. THE STRUCTURAL STEEL ERECTOR SHALL PROVIDE TEMPORARY GUYING AND BRACING AS REQUIRED. THE STRUCTURAL STEEL ERECTOR SHALL PROVIDE TEMPORARY GUYING AND BRACING AS REQUIRED. COLUMNS, ANCHOR BOLTS, BASE PLATES, ETC. HAVE BEEN DESIGNED FOR THE FINAL COMPLETE CONDITION, AND HAVE NOT BEEN INVESTIGATED FOR POTENTIAL LOADINGS ENCOUNTERED DURING STEEL ERECTION AND CONSTRUCTION. ANY INVESTIGATION OF THE COLUMNS, ANCHOR BOLTS, FRAMING, ETC. FOR ADEQUACY DURING THE STEEL ERECTION AND CONSTRUCTION PROCESS IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 8. STEEL FABRICATORS SHALL BE AN AISC CERTIFIED SHOP FOR CATEGORY I STEEL STRUCTURES AND STEEL FABRICATORS SHALL BE AN AISC CERTIFIED SHOP FOR CATEGORY I STEEL STRUCTURES AND MAINTAIN DETAILED QUALITY CONTROL PROCEDURES AS REQUIRED TO SATISFY THE SPECIAL INSPECTION REQUIREMENTS OF THE LATEST BUILDING CODE HAVING JURISDICTION. THIS REQUIREMENT MAY BE WAIVED AT THE OWNER'S DISCRETION PROVIDED THAT NECESSARY SHOP INSPECTIONS ARE PROVIDED. SEE SPECIAL INSPECTION NOTES FOR ADDITIONAL INFORMATION. 9. UNLESS OTHERWISE NOTED, STRUCTURAL STEEL PERMANENTLY EXPOSED TO THE WEATHER, UNLESS OTHERWISE NOTED, STRUCTURAL STEEL PERMANENTLY EXPOSED TO THE WEATHER, INCLUDING ALL BRICK SHELF ANGLES, SHALL BE HOT-DIP GALVANIZED IN ACCORDANCE WITH ASTM A123. PROTECTIVE PROTECTIVE COATING DAMAGED DURING THE TRANSPORT, ERECTING AND FIELD WELDING PROCESS SHALL BE REPAIRED IN THE FIELD TO MATCH THE SHOP APPLIED COATING. 10. THE OWNER WILL HIRE AN INDEPENDENT TESTING AGENCY TO PROVIDE SPECIAL INSPECTIONS OF THE OWNER WILL HIRE AN INDEPENDENT TESTING AGENCY TO PROVIDE SPECIAL INSPECTIONS OF THE BOLTING, WELDING, AND OTHER ITEMS IN ACCORDANCE WITH THE LATEST BUILDING CODES HAVING JURISDICTION. 11. REINFORCING SHALL BE PROVIDED AT CONNECTIONS WHERE CUTS HAVE REDUCED THE SHEAR OR REINFORCING SHALL BE PROVIDED AT CONNECTIONS WHERE CUTS HAVE REDUCED THE SHEAR OR MOMENT CAPACITY BELOW THAT REQUIRED TO SUSTAIN THE REACTION. FLANGES AND WEB ARE TO BE REINFORCED WHERE THE LOCAL CAPACITY TO SUSTAIN LOAD IS INADEQUATE. 12. MISCELLANEOUS IRON CONTRACTOR TO PROVIDE MISCELLANEOUS STEEL SHOWN ON ARCHITECTURAL MISCELLANEOUS IRON CONTRACTOR TO PROVIDE MISCELLANEOUS STEEL SHOWN ON ARCHITECTURAL DRAWINGS THAT IS NOT SHOWN ON STRUCTURAL DRAWINGS. 13. AT LOCATIONS ON THE ARCHITECTURAL DRAWINGS OR OTHER TRADES WHERE A STEEL ANGLE OR AT LOCATIONS ON THE ARCHITECTURAL DRAWINGS OR OTHER TRADES WHERE A STEEL ANGLE OR PLATE IS SHOWN DIAGRAMMATICALLY AND REFERENCE IS MADE TO THE STRUCTURAL DRAWINGS FOR SIZE, PROVIDE MINIMUM THICKNESS OF 3/8" MATERIAL AND PLATE WIDTH OR ANGLE SIZE AS SCALED FOR THE DRAWINGS. INSTALL THE PLATE OR ANGLE TO THE EXTENT REQUIRED TO ACCOMPLISH A COMPLETE JOB. 14. WHEN NO MEMBER SIZE IS GIVEN IN PLAN AND/OR SECTION, AND THE SIZE CANNOT BE WHEN NO MEMBER SIZE IS GIVEN IN PLAN AND/OR SECTION, AND THE SIZE CANNOT BE DETERMINED GRAPHICALLY, THE MINIMUM SIZE ASSUMED FOR BIDDING SHALL BE AS FOLLOWS: CHANNELS C12x25 CHANNELS C12x25 CHANNELS C12x25 C12x25 W-SHAPES W16x50 W-SHAPES W16x50 W16x50 ANGLES L6x6x1/2 ANGLES L6x6x1/2 L6x6x1/2 TUBES/HOLLOW SECTIONS HSS6x6x1/2 TUBES/HOLLOW SECTIONS HSS6x6x1/2 HSS6x6x1/2 PIPES/HOLLOW SECTIONS 6" X-STRONG PIPES/HOLLOW SECTIONS 6" X-STRONG 6" X-STRONG WT (TEE's) WT8x25 WT (TEE's) WT8x25 WT8x25 UNLESS OTHERWISE NOTED ALL MEMBERS INDICATED ON PLAN ARE W-SHAPES. FINAL SIZES SHALL BE CONFIRMED BY ENGINEER VIA A REQUEST FOR INFORMATION (RFI) DURING THE BID PERIOD OR DURING THE SHOP DRAWING PHASE. CONTRACTOR SHALL NOT BE ENTITLED TO COSTS FOR REVISIONS TO THE MEMBER SIZE IF AN RFI IS NOT SUBMITTED IN A TIMELY MANNER. STRUCTURAL STEEL SHALL BE PAINTED PER THE PROJECT SPECIFICATIONS. 15. THE CONTRACTOR IS REQUIRED TO PROVIDE AN AFFIDAVIT, AT THE COMPLETION OF THE JOB, TO THE CONTRACTOR IS REQUIRED TO PROVIDE AN AFFIDAVIT, AT THE COMPLETION OF THE JOB, TO THE EFFECT THAT THE STRUCTURAL STEEL FRAME IS PLUMB AND LEVEL WITHIN THE NORMAL TOLERANCES SPECIFIED BY CODE AND/OR PROJECT SPECIFICATIONS.
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
STEEL DECK GENERAL NOTES
AutoCAD SHX Text
1. METAL DECK, GAUGE AND TYPE ARE CALLED OUT AND INDICATED ON THE FRAMING PLANS AND THE METAL DECK, GAUGE AND TYPE ARE CALLED OUT AND INDICATED ON THE FRAMING PLANS AND THE GENERAL NOTES THAT ACCOMPANY THE FRAMING PLANS. 2. METAL DECK UNITS AND ACCESSORY ITEMS SHALL BE FORMED FROM STEEL SHEETS CONFORMING METAL DECK UNITS AND ACCESSORY ITEMS SHALL BE FORMED FROM STEEL SHEETS CONFORMING TO ASTM SPECIFICATION A-611 WITH A MINIMUM YIELD STRENGTH OF 33,000 PSI. BEFORE FORMING, THE STEEL SHEET SHALL RECEIVE A PROTECTIVE METAL COATING OR ZINC CONFORMING TO ASTM SPECIFICATION A-653, G60. 3. METAL DECK SHALL BE SHORED AS REQUIRED BY PLANS OR BY SPAN AND LOAD CONDITIONS TO METAL DECK SHALL BE SHORED AS REQUIRED BY PLANS OR BY SPAN AND LOAD CONDITIONS TO SUPPORT WET WEIGHT OF CONCRETE AND CONSTRUCTION LOADS. 4. METAL DECK SHALL BE COORDINATED WITH ALL ARCHITECTURAL AND ELECTRICAL/MECHANICAL METAL DECK SHALL BE COORDINATED WITH ALL ARCHITECTURAL AND ELECTRICAL/MECHANICAL REQUIREMENTS. 5. HANGING DIRECTLY FROM THE FLOOR DECK USING PIERCING HANGER TABS OR OTHER SIMILAR HANGING DIRECTLY FROM THE FLOOR DECK USING PIERCING HANGER TABS OR OTHER SIMILAR METHODS IS STRICTLY PROHIBITED. ANYTHING TO BE HUNG WITHIN THE CEILING PLENUM SHALL BE HUNG FROM THE STEEL FRAMING AND/OR ALTERNATE SUB-FRAMING THAT IS DESIGNED AND PROVIDED BY THE CONTRACTOR INSTALLING THE ITEMS TO BE HUNG WITHIN THE PLENUM. 6. UNFRAMED DECK OPENINGS IN COMPOSITE STEEL DECK WITH CONCRETE SHALL BE REINFORCED AS UNFRAMED DECK OPENINGS IN COMPOSITE STEEL DECK WITH CONCRETE SHALL BE REINFORCED AS FOLLOWS: A. ROUND HOLES 6" TO 10" IN DIAMETER: 14 GAUGE FLAT SHEET EXTENDING 8" ROUND HOLES 6" TO 10" IN DIAMETER: 14 GAUGE FLAT SHEET EXTENDING 8" : 14 GAUGE FLAT SHEET EXTENDING 8" BEYOND THE HOLE/OPENING ON ALL SIDES. THE FLAT SHEET REINFORCING SHALL BE WELDED TO THE TOP SIDE OF THE DECK. ADDITIONAL STEEL REBAR REINFORCING SHALL ALSO BE PLACED AROUND THE OPENING WITHIN THE SLAB CONSTRUCTION PER TYPICAL DETAILS TO PREVENT CONCRETE CRACKING. B. RECTANGULAR HOLES 6" TO 10" IN WIDTH PARALLEL TO THE DECK SPAN AND A RECTANGULAR HOLES 6" TO 10" IN WIDTH PARALLEL TO THE DECK SPAN AND A MAXIMUM OF 12" IN LENGTH PERPENDICULAR TO THE DECK SPAN: SIMILAR TO : SIMILAR TO THE REINFORCING PREVIOUSLY NOTED FOR ROUND HOLES. C. OPENINGS LARGER THAN THOSE NOTED ABOVE REQUIRE SUPPLEMENTAL STEEL OPENINGS LARGER THAN THOSE NOTED ABOVE REQUIRE SUPPLEMENTAL STEEL FRAMING; CONTRACTOR SHALL COORDINATE WITH THE TYPICAL DROP-IN ANGLE OR TYPICAL DROP-IN ANGLE OR OR TYPICAL DROP-IN FRAME DETAILS. DETAILS.
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
CAST-IN-PLACE CONCRETE GENERAL NOTES
AutoCAD SHX Text
1. CONCRETE WORK SHALL CONFORM WITH THE REQUIREMENTS OF THE AMERICAN CONCRETE INSTITUTE ACI CONCRETE WORK SHALL CONFORM WITH THE REQUIREMENTS OF THE AMERICAN CONCRETE INSTITUTE ACI 318 (LATEST EDITION). 2. COORDINATE WITH INDIVIDUAL PLANS AND SCHEDULES FOR REQUIRED CONCRETE STRENGTH AT 28 DAYS COORDINATE WITH INDIVIDUAL PLANS AND SCHEDULES FOR REQUIRED CONCRETE STRENGTH AT 28 DAYS FOR VARIOUS ELEMENTS (SLABS, BEAMS, COLUMNS, SHEAR WALLS, FOUNDATIONS, ETC.). 3. REINFORCEMENT SHALL BE DEFORMED BARS ASTM DESIGNATION A-615, GRADE 60. REINFORCEMENT SHALL BE DEFORMED BARS ASTM DESIGNATION A-615, GRADE 60. 4. CONCRETE PROTECTION FOR REINFORCEMENT SHALL CONFORM TO LATEST A.C.I. SPECIFICATION. CONCRETE PROTECTION FOR REINFORCEMENT SHALL CONFORM TO LATEST A.C.I. SPECIFICATION. 5. TEMPERATURE REINFORCING SHALL BE SUFFICIENTLY EMBEDDED TO DEVELOP FULL STRENGTH IN TEMPERATURE REINFORCING SHALL BE SUFFICIENTLY EMBEDDED TO DEVELOP FULL STRENGTH IN CONCRETE WALLS AND SLABS. 6. PROVIDE ADEQUATE TIES FOR REINFORCEMENT IN SLABS, BEAMS, PIERS AND WALLS. REINFORCEMENT TO PROVIDE ADEQUATE TIES FOR REINFORCEMENT IN SLABS, BEAMS, PIERS AND WALLS. REINFORCEMENT TO BE HELD AT CORRECT DISTANCE FROM FORMS AND EARTH BY STEEL CHAIRS OR TIES. 7. FOLLOW C.R.S.I. RULES FOR PLACING OF REINFORCING STEEL AND ACCESSORIES. FOLLOW C.R.S.I. RULES FOR PLACING OF REINFORCING STEEL AND ACCESSORIES. 8. NO CONCRETE SHALL BE CAST UNTIL THE PRELIMINARY TESTS REQUIRED HAVE BEEN MADE, REPORTS NO CONCRETE SHALL BE CAST UNTIL THE PRELIMINARY TESTS REQUIRED HAVE BEEN MADE, REPORTS THEREOF FILED WITH THE ENGINEER, AND APPROVED. THE CONTROLLED CONCRETE TO BE USED SHALL CONFORM TO THE APPROVED DESIGN MIX OBTAINED AS A RESULT OF THE PRELIMINARY TESTS. THE USE OF ANY ADDITIVES NOT PRESENT IN THE PRELIMINARY TEST MIX IS PROHIBITED. 9. REPRESENTATIVE TEST CYLINDERS WILL BE TAKEN FROM THE CONCRETE PLACED EACH DAY IN REPRESENTATIVE TEST CYLINDERS WILL BE TAKEN FROM THE CONCRETE PLACED EACH DAY IN ACCORDANCE WITH CONCRETE SPECIFICATIONS. 10. WELDED WIRE FABRIC SHALL HAVE A MINIMUM ULTIMATE STRENGTH OF 70,000 PSI AND SHALL CONFORM WELDED WIRE FABRIC SHALL HAVE A MINIMUM ULTIMATE STRENGTH OF 70,000 PSI AND SHALL CONFORM TO ASTM A-185 AND A-497. 11. MESH SHALL BE SPLICED SO THAT THE OVERLAP BETWEEN OUTERMOST CROSS WIRES OF EACH SHEET IS MESH SHALL BE SPLICED SO THAT THE OVERLAP BETWEEN OUTERMOST CROSS WIRES OF EACH SHEET IS NOT LESS THAN THE SPACING OF THE CROSS WIRES PLUS TWO INCHES, UNLESS OTHERWISE SHOWN ON THE DRAWINGS. 12. THIS CONTRACTOR SHALL COOPERATE WITH OTHER TRADES AND WHERE REQUIRED INSTALL ALL BUILT-IN THIS CONTRACTOR SHALL COOPERATE WITH OTHER TRADES AND WHERE REQUIRED INSTALL ALL BUILT-IN WORK, SLEEVES, INSERTS, ETC., AS REQUIRED FOR A COMPLETE JOB. 13. STRUCTURAL MEMBERS SHALL BE POURED FOR THEIR FULL DEPTHS IN ONE OPERATION. CONSTRUCTION STRUCTURAL MEMBERS SHALL BE POURED FOR THEIR FULL DEPTHS IN ONE OPERATION. CONSTRUCTION JOINTS SUCH AS A DAY'S POUR JOINTS SHALL BE LOCATED IN THE MIDDLE THIRD OF THE SPAN, MAIN REINFORCING TO RUN THROUGH THE JOINT, KEY AND ROUGHEN JOINTS TO EXPOSE AGGREGATE FOR CHEMICAL BOND. 14. NO HORIZONTAL JOINTS SHALL BE PLACED IN WALLS EXCEPT AS SHOWN ON THE DRAWINGS, WITHOUT NO HORIZONTAL JOINTS SHALL BE PLACED IN WALLS EXCEPT AS SHOWN ON THE DRAWINGS, WITHOUT THE APPROVAL OF THE ENGINEER. 15. STRUCTURAL SLABS ON GRADE SHALL BE OF A THICKNESS AND REINFORCED AS INDICATED ON DRAWINGS. STRUCTURAL SLABS ON GRADE SHALL BE OF A THICKNESS AND REINFORCED AS INDICATED ON DRAWINGS. 16. SLABS-ON-GRADE SHALL HAVE THICKENINGS, DEPRESSIONS, OPENINGS, ETC., AS REQUIRED OR AS SLABS-ON-GRADE SHALL HAVE THICKENINGS, DEPRESSIONS, OPENINGS, ETC., AS REQUIRED OR AS SHOWN HEREIN OR ON ARCHITECTURAL DRAWINGS. 17. LOCATION OF CUTOFF POINTS FOR CONCRETE BEAM REINFORCEMENT SHALL BE AS SHOWN ON TYP. LOCATION OF CUTOFF POINTS FOR CONCRETE BEAM REINFORCEMENT SHALL BE AS SHOWN ON TYP. DETAILS. 18. PROVIDE 100% CONTINUITY OVER SUPPORTS FOR CONTINUOUS SLABS AND BEAMS. PROVIDE 100% CONTINUITY OVER SUPPORTS FOR CONTINUOUS SLABS AND BEAMS. 19. PROVIDE TWO #5 BARS AT REENTRANT CORNERS AND AROUND OPENINGS IN ANY CONCRETE WALL, BEAM, PROVIDE TWO #5 BARS AT REENTRANT CORNERS AND AROUND OPENINGS IN ANY CONCRETE WALL, BEAM, SLAB, GRADE BEAM OR MASONRY BEARING WALL. 20. PROVIDE POCKETS IN WALLS FOR COLUMNS, BEAMS AND SLABS. PROVIDE POCKETS IN WALLS FOR COLUMNS, BEAMS AND SLABS. 21. MINIMUM BEARING ON WALL OR BEAMS 4" FOR SLABS, 8" FOR BEAMS (U.O.N.). MINIMUM BEARING ON WALL OR BEAMS 4" FOR SLABS, 8" FOR BEAMS (U.O.N.). 22. PROVIDE PRECAST LINTELS FOR ALL OPENINGS OR RECESSES IN BLOCK WALLS WHERE NO SPECIFIC PROVIDE PRECAST LINTELS FOR ALL OPENINGS OR RECESSES IN BLOCK WALLS WHERE NO SPECIFIC LINTEL IS NOTED. 23. TOP ELEVATION OF SLABS SHALL VARY ACCORDING TO FINISH FLOOR MATERIAL. SEE ARCH'L DRAWINGS. TOP ELEVATION OF SLABS SHALL VARY ACCORDING TO FINISH FLOOR MATERIAL. SEE ARCH'L DRAWINGS. 24. SEE MECHANICAL AND ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF ALL OPENINGS IN ROOF, SEE MECHANICAL AND ARCHITECTURAL DRAWINGS FOR SIZE AND LOCATION OF ALL OPENINGS IN ROOF, FLOORS AND WALLS NOT SHOWN ON STRUCTURAL DRAWINGS. 25. IN ANY APPROVED CONSTRUCTION JOINT, PROVIDE 2" x 4" KEY AND 48 BAR DIAMETER LAP (16" MIN) IN ANY APPROVED CONSTRUCTION JOINT, PROVIDE 2" x 4" KEY AND 48 BAR DIAMETER LAP (16" MIN) OF REINFORCING, EXCEPT FOR SLABS-ON-GRADE.
lgamble Snapshot
S0.2
G E N
E R
A L N
O T
E S
.2
4.
Pr og re ss
P rin ts
0%
S
ET
R ev is io ns
C he ck ed
B y:
D ra w n
By
C on st ru ct io n Is su e
D at e:
Sc al e:
A
S N
O
TE
D
N or ris to w n
R oa d, S ui te e
Be ll, P A
Ph on e:
.8
.7 im ile : 6
.8
.7
C O
PY
R
IG
H
T
K
IM
M
EL
B
O G
R
ET
TE
A
R C
H
IT
EC
TU
R E
S
IT
E, I N
C
AL
L
R
IG
H
TS
R
ES
ER
VE
D
A r c h i t e c t u i t e c
PO
C
O N
O T
O W
N
SH
IP
M
U N
IC
IP
AL
C
O M
PL
EX
N C
C B
U
IL
D
IN
G O
LD
M
IL
L
R O
AD
TA
N
N
ER
SV
IL
LE
P
A
C
L BA
M
.3 0.
BI
D / P
ER
M
IT
S
ET
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
STATEMENT OF TESTING AND SPECIAL INSPECTION REQUIREMENTS
AutoCAD SHX Text TESTING: OWNER SHALL ENGAGE A QUALIFIED INDEPENDENT TESTING AND INSPECTING AGENCY TO PERFORM THE FOLLOWING SERVICES. OWNER SHALL ENGAGE A QUALIFIED INDEPENDENT TESTING AND INSPECTING AGENCY TO PERFORM THE FOLLOWING SERVICES. SHALL ENGAGE A QUALIFIED INDEPENDENT TESTING AND INSPECTING AGENCY TO PERFORM THE FOLLOWING SERVICES. ALL CODE SECTIONS REFERENCE 2020 BUILDING CODE OF NEW YORK STATE UNLESS OTHERWISE NOTED. 1. SOILS: SPECIAL INSPECTIONS AND TESTS OF EXISTING SITE SOIL CONDITIONS, FILL PLACEMENT AND LOAD-BEARING REQUIREMENTS SOILS: SPECIAL INSPECTIONS AND TESTS OF EXISTING SITE SOIL CONDITIONS, FILL PLACEMENT AND LOAD-BEARING REQUIREMENTS : SPECIAL INSPECTIONS AND TESTS OF EXISTING SITE SOIL CONDITIONS, FILL PLACEMENT AND LOAD-BEARING REQUIREMENTS SHALL BE PERFORMED IN ACCORDANCE WITH SECTION 1705.6. PROVIDE INSPECTION AND TESTING OF ALL STRUCTURAL FILL WITH REPORTS SUBMITTED TO THE ARCHITECT STATING COMPLIANCE OR NONCOMPLIANCE WITH PERCENT COMPACTION REQUIREMENTS. 2. CONCRETE CONSTRUCTION: SHALL BE INSPECTED PER THE REQUIREMENTS OF SECTION 1705.3 AND TABLE 1705.3. CONCRETE CONSTRUCTION: SHALL BE INSPECTED PER THE REQUIREMENTS OF SECTION 1705.3 AND TABLE 1705.3. : SHALL BE INSPECTED PER THE REQUIREMENTS OF SECTION 1705.3 AND TABLE 1705.3. 3. MASONRY CONSTRUCTION: SHALL BE INSPECTED PER THE REQUIREMENTS OF SECTION 1704.5.4. MASONRY CONSTRUCTION: SHALL BE INSPECTED PER THE REQUIREMENTS OF SECTION 1704.5.4. : SHALL BE INSPECTED PER THE REQUIREMENTS OF SECTION 1704.5.4. 4. STRUCTURAL STEEL: SPECIAL INSPECTIONS AND NONDESTRUCTIVE TESTING OF STRUCTURAL STEEL ELEMENTS IN BUILDING, STRUCTURAL STEEL: SPECIAL INSPECTIONS AND NONDESTRUCTIVE TESTING OF STRUCTURAL STEEL ELEMENTS IN BUILDING, : SPECIAL INSPECTIONS AND NONDESTRUCTIVE TESTING OF STRUCTURAL STEEL ELEMENTS IN BUILDING, STRUCTURES 5. STEEL CONSTRUCTION: SPECIAL INSPECTIONS AND NONDESTRUCTIVE TESTING OF THE ON-SITE ERECTION OF STEEL CONSTRUCTION STEEL CONSTRUCTION: SPECIAL INSPECTIONS AND NONDESTRUCTIVE TESTING OF THE ON-SITE ERECTION OF STEEL CONSTRUCTION : SPECIAL INSPECTIONS AND NONDESTRUCTIVE TESTING OF THE ON-SITE ERECTION OF STEEL CONSTRUCTION IN BUILDINGS, STRUCTURES AND PORTIONS THEREOF SHALL BE IN ACCORDANCE WITH SECTION 1705.2. 6. FABRICATION INSPECTION: SPECIAL INSPECTION OF FABRICATED STRUCTURAL MEMBERS SHALL BE PERFORMED UNLESS: FABRICATION INSPECTION: SPECIAL INSPECTION OF FABRICATED STRUCTURAL MEMBERS SHALL BE PERFORMED UNLESS: : SPECIAL INSPECTION OF FABRICATED STRUCTURAL MEMBERS SHALL BE PERFORMED UNLESS: 6.1. FABRICATOR MAINTAINS APPROVED DETAILED FABRICATION AND QUALITY CONTROL PROCEDURES THAT PROVIDE A BASIS FOR FABRICATOR MAINTAINS APPROVED DETAILED FABRICATION AND QUALITY CONTROL PROCEDURES THAT PROVIDE A BASIS FOR CONTROL OF THE WORKMANSHIP AND THE FABRICATOR'S ABILITY TO CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND 2020 BUILDING CODE OF NEW YORK STATE. APPROVAL SHALL BE BASED UPON REVIEW OF THE FABRICATION AND QUALITY CONTROL PROCEDURES AND PERIODIC INSPECTION OF FABRICATION PRACTICES BY THE BUILDING OFFICIAL. 6.2. FABRICATOR IS REGISTERED AND APPROVED IN ACCORDANCE WITH SECTION 1704.2.5.1. FABRICATOR IS REGISTERED AND APPROVED IN ACCORDANCE WITH SECTION 1704.2.5.1. 7. WRITTEN REPORTS SHALL BE SUBMITTED TO THE ARCHITECT STATING COMPLIANCE OR NONCOMPLIANCE WITH THE DESIGN WRITTEN REPORTS SHALL BE SUBMITTED TO THE ARCHITECT STATING COMPLIANCE OR NONCOMPLIANCE WITH THE DESIGN DOCUMENTS. ALL REPORTS SHALL BE SIGNED AND SEALED BY A LICENSED ENGINEER FROM THE STATE OF NEW YORK. 8. FAILURE TO RETAIN A TESTING AGENCY TO PERFORM THE REQUIRED SERVICES SPECIFIED ABOVE, OR FAILURE TO SUBMIT SIGNED FAILURE TO RETAIN A TESTING AGENCY TO PERFORM THE REQUIRED SERVICES SPECIFIED ABOVE, OR FAILURE TO SUBMIT SIGNED AND SEALED REPORTS, INDICATES NONCOMPLIANCE WITH THE CONTRACT DOCUMENTS. 9. SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING CONSTRUCTION DOCUMENTS FOR ADDITIONAL NON-STRUCTURAL SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING CONSTRUCTION DOCUMENTS FOR ADDITIONAL NON-STRUCTURAL SPECIAL INSPECTION ITEMS.
AutoCAD SHX Text
DESIGN INFORMATION
AutoCAD SHX Text
2018 INTERNATIONAL BUILDING CODE
AutoCAD SHX Text
WIND DESIGN DATA
AutoCAD SHX Text
BASIC WIND SPEED (V3S) = 125 MPH3S) = 125 MPH) = 125 MPH125 MPH
AutoCAD SHX Text
EXPOSURE CATEGORY = B
AutoCAD SHX Text
SNOW LOAD
AutoCAD SHX Text GROUND SNOW LOAD (Pg) = 50 PSFg) = 50 PSF) = 50 PSF 50 PSF50 PSF
AutoCAD SHX Text FLAT ROOF SNOW LOAD (Pf) = 42 PSFf) = 42 PSF) = 42 PSF42 PSF
AutoCAD SHX Text SNOW EXPOSURE FACTOR (Ce) = 1.2e) = 1.2) = 1.21.2
AutoCAD SHX Text
GUST EFFECT FACTOR (G) = 0.85
AutoCAD SHX Text INTERNAL PRESSURE COEFFICIENT (GCpi) = ±0.18
AutoCAD SHX Text SNOW IMPORTANCE FACTOR (Is) = 1.0s) = 1.0) = 1.0
AutoCAD SHX Text SNOW THERMAL FACTOR (Ct) = 1.0t) = 1.0) = 1.0
AutoCAD SHX Text
SUPERIMPOSED DEAD LOADS
AutoCAD SHX Text
DESIGN LIVE LOADS
AutoCAD SHX Text
OCCUPANCY OR USE
AutoCAD SHX Text
PSF
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
10 PSF
AutoCAD SHX Text
- ROOFING & INSULATION
AutoCAD SHX Text
5 PSF
AutoCAD SHX Text
- CEILING
AutoCAD SHX Text
5 PSF
AutoCAD SHX Text
- MECHANICAL/ELECTRICAL
AutoCAD SHX Text
- TOTAL *
AutoCAD SHX Text
20 PSF
AutoCAD SHX Text
* DOES NOT INCLUDE FRAMING SELF WEIGHT.DOES NOT INCLUDE FRAMING SELF WEIGHT.NOT INCLUDE FRAMING SELF WEIGHT. INCLUDE FRAMING SELF WEIGHT.
AutoCAD SHX Text
COMPONENTS AND CLADDING
AutoCAD SHX Text
EARTHQUAKE DESIGN DATA
AutoCAD SHX Text
SEISMIC IMPORTANCE FACTOR
AutoCAD SHX Text
ANALYSIS PROCEDURE = EQUIVALENT LATERAL FORCE PROCEDURE
AutoCAD SHX Text
SITE CLASS = D (ASSUMED IN ABSENCE OF GEOTECHNICAL REPORT)
AutoCAD SHX Text
PLAN STRUCTURAL IRREGULARITIES = NO= NONO
AutoCAD SHX Text
VERTICAL STRUCTURAL IRREGULARITIES = NO= NONO
AutoCAD SHX Text
0.2 SPECTRAL RESPONSE ACCELERATION
AutoCAD SHX Text
1.0 SPECTRAL RESPONSE ACCELERATION
AutoCAD SHX Text
DAMPED DESIGN SPECTRAL RESPONSE
AutoCAD SHX Text
ACCELERATION (SHORT PERIOD)
AutoCAD SHX Text
DAMPED DESIGN SPECTRAL RESPONSE
AutoCAD SHX Text ACCELERATION (1-second PERIOD)
AutoCAD SHX Text
SEISMIC DESIGN CATEGORY = C
AutoCAD SHX Text
RISK CATEGORY = IV
AutoCAD SHX Text Ie = 1.5e = 1.5= 1.5
AutoCAD SHX Text S = 0.163s= 0.163
AutoCAD SHX Text S = 0.0431= 0.043
AutoCAD SHX Text S = 0.15ds= 0.15
AutoCAD SHX Text S = 0.061d1= 0.061
AutoCAD SHX Text
EFFECTIVE WIND AREA (SF)
AutoCAD SHX Text
VERTICAL PRESSURES (ROOF)
AutoCAD SHX Text
HORIZONTAL PRESSURES (WALL)
AutoCAD SHX Text
ZONE 1 (INTERIOR)
AutoCAD SHX Text
ZONE 2 (PERIMETER)
AutoCAD SHX Text
ZONE 3 (CORNER)
AutoCAD SHX Text
ZONE 4 (INTERIOR)
AutoCAD SHX Text
ZONE 5 (EXTERIOR)
AutoCAD SHX Text
10 SF
AutoCAD SHX Text
20 SF
AutoCAD SHX Text
50 SF
AutoCAD SHX Text
100 SF
AutoCAD SHX Text
+16 PSF -23 PSF
AutoCAD SHX Text
+16 PSF -39 PSF
AutoCAD SHX Text
+16 PSF -58 PSF
AutoCAD SHX Text
+23 PSF -25 PSF
AutoCAD SHX Text
+23 PSF -31 PSF
AutoCAD SHX Text
+16 PSF -23 PSF
AutoCAD SHX Text
+16 PSF -35 PSF
AutoCAD SHX Text
+16 PSF -48 PSF
AutoCAD SHX Text
+16 PSF -22 PSF
AutoCAD SHX Text
+16 PSF -29 PSF
AutoCAD SHX Text
+16 PSF -35 PSF
AutoCAD SHX Text
+21 PSF -23 PSF
AutoCAD SHX Text
+21 PSF -26 PSF
AutoCAD SHX Text
+16 PSF -21 PSF
AutoCAD SHX Text
+16 PSF -25 PSF
AutoCAD SHX Text
+16 PSF -25 PSF
AutoCAD SHX Text
+20 PSF -22 PSF
AutoCAD SHX Text
+20 PSF -24 PSF
AutoCAD SHX Text
COMPONENTS AND CLADDING WIND PRESSURES (PSF)
AutoCAD SHX Text
* THIRD PARTY ENGINEER(S) MAY INTERPOLATE AS REQUIRED THIRD PARTY ENGINEER(S) MAY INTERPOLATE AS REQUIRED BASED ON ACTUAL EFFECTIVE WIND AREA OF COMPONENT OR CLADDING ELEMENT BEING DESIGNED.
AutoCAD SHX Text
ELEVATED SLABS
AutoCAD SHX Text
5 PSF
AutoCAD SHX Text
- CEILING
AutoCAD SHX Text
5 PSF
AutoCAD SHX Text
- MEP
AutoCAD SHX Text
80 PSF
AutoCAD SHX Text
- TOTAL *
AutoCAD SHX Text
LIGHT STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
STAIRS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LOBBIES, LOUNGES & VESTIBULES
AutoCAD SHX Text
MULTIPURPOSE
AutoCAD SHX Text
CORRIDORS
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDORS ABOVE FIRST FLOOR
AutoCAD SHX Text
AutoCAD SHX Text
+22 PSF -24 PSF
AutoCAD SHX Text
+22 PSF -29 PSF
AutoCAD SHX Text
65 PSF
AutoCAD SHX Text
- 4" NW CONC. ON 2" 20-GA. DECK
AutoCAD SHX Text
5 PSF
AutoCAD SHX Text
- FLOORING
AutoCAD SHX Text
TABLE 1705.2.4: REQUIRED SPECIAL INSPECTIONS
AutoCAD SHX Text
TYPE OF INSPECTION
AutoCAD SHX Text
FREQUENCY OF INSPECTION
AutoCAD SHX Text REFERENCED STANDARD [a]
AutoCAD SHX Text
1. INSTALLATION OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERSINSTALLATION OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
AutoCAD SHX Text
a. END CONNECTIONS - WELDING OR BOLTED.END CONNECTIONS - WELDING OR BOLTED.
AutoCAD SHX Text
b. BRIDGING - HORIZONTAL OR DIAGONAL. BRIDGING - HORIZONTAL OR DIAGONAL.
AutoCAD SHX Text
SJI SPECIFICATIONS LISTED IN 2207.1
AutoCAD SHX Text
OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
1. STANDARD BRIDGING.
AutoCAD SHX Text
2. BRIDGING THAT DIFFERS FROM THE SJI SPECIFICATIONS LISTED IN SECTION 2207.1
AutoCAD SHX Text
SJI SPECIFICATIONS LISTED IN 2207.1
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text [a] WHERE APPLICABLE, SEE SECTION 1705.13.WHERE APPLICABLE, SEE SECTION 1705.13.
AutoCAD SHX Text
TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
AutoCAD SHX Text
SPECIAL INSPECTION REQUIRED Y/N
AutoCAD SHX Text
VERIFICATION AND INSPECTION TASK
AutoCAD SHX Text
FREQUENCY OF INSPECTION
AutoCAD SHX Text
REFERENCE FOR CRITERIA
AutoCAD SHX Text
1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING INSPECT REINFORCEMENT, INCLUDING PRESTRESSING TENDONS, AND VERIFY PLACEMENT.
AutoCAD SHX Text
IBC REFERENCE
AutoCAD SHX Text
REFERENCED STANDARD
AutoCAD SHX Text
YES
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
ACI 318 CH. 20, 25.2, 25.3, 26.6.1-26.6.3
AutoCAD SHX Text
AutoCAD SHX Text
2. REINFORCING BAR WELDING:REINFORCING BAR WELDING:
AutoCAD SHX Text
ACI 318: 26.13.3.3
AutoCAD SHX Text
AutoCAD SHX Text
3. INSPECT ANCHORS CAST IN CONCRETE.INSPECT ANCHORS CAST IN CONCRETE.
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
YES
AutoCAD SHX Text
AutoCAD SHX Text
4. INSPECT ANCHORS POST-INSTALLED IN HARDENED INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS [b]:
AutoCAD SHX Text
YES
AutoCAD SHX Text
5. VERIFY USE OF REQUIRED DESIGN MIX.VERIFY USE OF REQUIRED DESIGN MIX.
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
ACI 318 CH. 19, 26.4.3, 26.4.4
AutoCAD SHX Text 1904.1, 1904.2
AutoCAD SHX Text
6. PRIOR TO CONCRETE PLACEMENT, FABRICATE PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE.
AutoCAD SHX Text
YES
AutoCAD SHX Text
YES
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
ASTM C172 ASTM C31 ACI 318: 26.5, 26.12
AutoCAD SHX Text
AutoCAD SHX Text
7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES.
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
ACI 318: 26.5
AutoCAD SHX Text
AutoCAD SHX Text
YES
AutoCAD SHX Text
8. VERIFY MAINTENANCE OF SPECIFIED CURING VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
ACI 318: 26.5.3-26.5.5
AutoCAD SHX Text
AutoCAD SHX Text
YES
AutoCAD SHX Text
9. INSPECT PRESTRESSED CONCRETE FOR:INSPECT PRESTRESSED CONCRETE FOR:
AutoCAD SHX Text
NO
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
ACI 318: 26.10
AutoCAD SHX Text
AutoCAD SHX Text
ACI 318: CH. 26.9
AutoCAD SHX Text
AutoCAD SHX Text
10. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS.INSPECT ERECTION OF PRECAST CONCRETE MEMBERS.
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
NO
AutoCAD SHX Text
13. VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN POST-TENSIONED CONCRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS IN BEAMS AND STRUCTURAL SLABS.
AutoCAD SHX Text
NO
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
ACI 318: 26.11.2
AutoCAD SHX Text
AutoCAD SHX Text
14. INSPECT FORMWORK FOR SHAPE, LOCATION AND INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.
AutoCAD SHX Text
YES
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text ACI 318: 26.11.1.2(b)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
c. INSPECT WELDED REINFORCEMENT SPLICES.INSPECT WELDED REINFORCEMENT SPLICES.
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
YES
AutoCAD SHX Text
AWS D1.4 ACI 318: 26.13.1.4
AutoCAD SHX Text
AutoCAD SHX Text
a. VERIFY WELDABABILITY OF REINFORCING BARS VERIFY WELDABABILITY OF REINFORCING BARS OTHER THAN ASTM A706.
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
YES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
d. INSPECT WELDING OF PRIMARY TENSION INSPECT WELDING OF PRIMARY TENSION REINFORCEMENT IN CORBELS.
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
YES
AutoCAD SHX Text
AWS D1.4 ACI 318: 26.13.3
AutoCAD SHX Text
AutoCAD SHX Text
b. INSPECT WELDING OF REINFORCEMENT FOR INSPECT WELDING OF REINFORCEMENT FOR SPECIAL MOMENT FRAMES, BOUNDARY ELEMENTS OF SPECIAL STRUCTURAL WALLS AND COUPLING BEAMS.
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
YES
AutoCAD SHX Text
AWS D1.4 ACI 318: 26.13.3
AutoCAD SHX Text
AutoCAD SHX Text
e. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM "INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM "516"
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
YES
AutoCAD SHX Text
AWS D1.4 ACI 318: 26.13.3
AutoCAD SHX Text
AutoCAD SHX Text
f. INSPECT ALL OTHER WELDS.INSPECT ALL OTHER WELDS.
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
YES
AutoCAD SHX Text
a. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS.
AutoCAD SHX Text
b. MECHANICAL ANCHORS AND ADHESIVE ANCHORS MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4a.
AutoCAD SHX Text
YES
AutoCAD SHX Text
AutoCAD SHX Text
ACI 318: 26.13.3.2
AutoCAD SHX Text
ACI 318: 26.13.3
AutoCAD SHX Text
b. GROUTING OF BONDED PRESTRESSING TENDONS.GROUTING OF BONDED PRESTRESSING TENDONS.
AutoCAD SHX Text
a. APPLICATION OF PRESTRESSING FORCES; AND APPLICATION OF PRESTRESSING FORCES; AND
AutoCAD SHX Text
NO
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
ACI 318: 26.10
AutoCAD SHX Text
AutoCAD SHX Text
11. FOR PRECAST CONCRETE DIAPHRAGM CONNECTIONS FOR PRECAST CONCRETE DIAPHRAGM CONNECTIONS OR REINFORCEMENT AT JOINTS CLASSIFIED AS MODERATE OR HIGH DEFORMABILITY ELEMENTS (MDE OR HDE) IN STRUCTURES ASSIGNED TO SEISMIC DESIGN CATEGORY C, D, E OR F, INSPECT SUCH CONNECTIONS AND REINFORCEMENT IN THE FIELD FOR:
AutoCAD SHX Text
a. INSTALLATION OF THE EMBEDDED PARTS.INSTALLATION OF THE EMBEDDED PARTS.
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
ACI 318: 26.13.1.3
AutoCAD SHX Text
YES
AutoCAD SHX Text
b. COMPLETION OF THE CONTINUITY OF COMPLETION OF THE CONTINUITY OF REINFORCEMENT ACROSS JOINTS.
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
ACI 550.5
AutoCAD SHX Text
YES
AutoCAD SHX Text
12. INSPECT INSTALLATION TOLERANCES OF PRECAST INSPECT INSTALLATION TOLERANCES OF PRECAST CONCRETE DIAPHRAGM CONNECTIONS FOR COMPLIANCE WITH ACI 550.5.
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text
ACI 318: 26.13.1.3
AutoCAD SHX Text
AutoCAD SHX Text
YES
AutoCAD SHX Text
c. COMPLETION OF CONNECTIONS IN THE FIELD.COMPLETION OF CONNECTIONS IN THE FIELD.
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
AutoCAD SHX Text
YES
AutoCAD SHX Text
CONTINUOUS
AutoCAD SHX Text
PERIODIC
AutoCAD SHX Text FOR SI: 1 inch = 25.4 mm. [a] WHERE APPLICABLE, SEE SECTION 1705.13. WHERE APPLICABLE, SEE SECTION 1705.13. [b] SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH 26.13 IN ACI 318, OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR TO THE COMMENCEMENT OF THE WORK.
AutoCAD SHX Text
(UNLESS OTHERWISE NOTED OR SHOWN ON PLAN, THE FOLLOWING NOTES SHALL APPLY)
AutoCAD SHX Text
MASONRY GENERAL NOTES
AutoCAD SHX Text
1. WALL DESIGN ALLOWABLE STRESSES ARE BASED ON "SPECIAL INSPECTION" REQUIREMENTS OF ACI WALL DESIGN ALLOWABLE STRESSES ARE BASED ON "SPECIAL INSPECTION" REQUIREMENTS OF ACI SPECIAL INSPECTION" REQUIREMENTS OF ACI " REQUIREMENTS OF ACI 530.1/ ASCE 6 / TMS 602 LATEST EDITION. CONSTRUCTION OF WALLS MUST BE PERFORMED IN ACCORDANCE WITH REQUIREMENTS FOR LEVEL B QUALITY ASSURANCE GUIDELINES DEFINED BY ACI 530. 2. CONCRETE MASONRY UNITS (CMU) SHALL CONFORM TO ASTM C90 FOR LOAD BEARING UNITS. CMU CONCRETE MASONRY UNITS (CMU) SHALL CONFORM TO ASTM C90 FOR LOAD BEARING UNITS. CMU SHALL BE NORMAL WEIGHT. 3. CMU BLOCK SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 1,900 PSI ON THE NET AREA OF CMU BLOCK SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 1,900 PSI ON THE NET AREA OF THE BLOCK. 4. MINIMUM f'm SHALL BE 1,500 PSI. MINIMUM f'm SHALL BE 1,500 PSI. 5. COMPRESSIVE STRENGTH OF THE GROUT SHALL BE A MINIMUM OF 3,000 PSI WITH A 8" TO 11" COMPRESSIVE STRENGTH OF THE GROUT SHALL BE A MINIMUM OF 3,000 PSI WITH A 8" TO 11" SLUMP AND COMPLY WITH REQUIREMENTS FOR FINE GROUT PER ASTM 476 (3/8" TO 1/2") MAXIMUM SIZE AGGREGATE DETERMINED IN ACCORDANCE WITH ASTM C1019. 6. MORTAR SHALL BE TYPE S HIGH STRENGTH MORTAR CONFORMING TO ASTM C270. MORTAR SHALL BE TYPE S HIGH STRENGTH MORTAR CONFORMING TO ASTM C270. 7. GROUTING PROCEDURES SHALL BE IN STRICT COMPLIANCE WITH RECOMMENDATIONS AS OUTLINED BY GROUTING PROCEDURES SHALL BE IN STRICT COMPLIANCE WITH RECOMMENDATIONS AS OUTLINED BY NCMA AND ACI. 8. BELOW GRADE: ALL CELLS FULLY GROUTED SOLID. ABOVE GRADE: CELLS RECEIVING REINFORCING BELOW GRADE: ALL CELLS FULLY GROUTED SOLID. ABOVE GRADE: CELLS RECEIVING REINFORCING SHALL BE FULLY GROUTED. 9. MASONRY UNITS SHALL BE LAID IN A RUNNING BOND PATTERN WITH FULL FACE SHELL MORTAR BEDS. MASONRY UNITS SHALL BE LAID IN A RUNNING BOND PATTERN WITH FULL FACE SHELL MORTAR BEDS. 10. AREAS ADJACENT TO OPENINGS SHALL BE REINFORCED PER THE TYPICAL PILASTER DETAILS. AREAS ADJACENT TO OPENINGS SHALL BE REINFORCED PER THE TYPICAL PILASTER DETAILS. 11. STARTING JOINT FOR ALL MASONRY SHALL BE LAID WITH FULL BED MORTAR COVERAGE. STARTING JOINT FOR ALL MASONRY SHALL BE LAID WITH FULL BED MORTAR COVERAGE. 12. MORTAR SHALL BE APPLIED TO CROSS WEBS OF CMU IN ADDITION TO HORIZONTAL AND VERTICAL MORTAR SHALL BE APPLIED TO CROSS WEBS OF CMU IN ADDITION TO HORIZONTAL AND VERTICAL EDGES OF AREAS OF BEAM BEARING AREAS. 13. REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ASTM A-615 GRADE 60. SHOP FABRICATE REINFORCING STEEL SHALL BE IN ACCORDANCE WITH ASTM A-615 GRADE 60. SHOP FABRICATE REINFORCING BARS WHICH ARE SHOWN TO BE HOOKED OR BENT. PROVIDE A MINIMUM LAP OF 48 X BAR DIAMETER AT ALL SPLICES, UNLESS OTHERWISE INDICATED. 14. UNLESS OTHERWISE INDICATED IN SECTION OR NOTED PROVIDE MINIMUM VERTICAL AND HORIZONTAL UNLESS OTHERWISE INDICATED IN SECTION OR NOTED PROVIDE MINIMUM VERTICAL AND HORIZONTAL REINFORCING FOR ALL MASONRY WALLS AS FOLLOWS: - FOR ALL INTERIOR 8" WALLS, PROVIDE A MINIMUM (1) #5 VERTICAL REBAR SPACED 48" ON FOR ALL INTERIOR 8" WALLS, PROVIDE A MINIMUM (1) #5 VERTICAL REBAR SPACED 48" ON CENTER MAXIMUM, CONTINUOUSLY FROM SUPPORT TO SUPPORT. IN ADDITION PROVIDE (1) #5 REBAR EACH SIDE OF EACH OPENING AND AT ENDS OF WALLS. ALSO, MAKE THESE BARS CONTINUOUS FROM SUPPORT-TO-SUPPORT. - FOR ALL INTERIOR 6" WALLS, PROVIDE A MINIMUM (1) #5 VERTICAL REBAR SPACED 16" ON FOR ALL INTERIOR 6" WALLS, PROVIDE A MINIMUM (1) #5 VERTICAL REBAR SPACED 16" ON CENTER MAXIMUM, CONTINUOUSLY FROM SUPPORT TO SUPPORT. IN ADDITION PROVIDE (1) #5 REBAR EACH SIDE OF EACH OPENING AND AT ENDS OF WALLS. ALSO, MAKE THESE BARS CONTINUOUS FROM SUPPORT TO SUPPORT. - FOR ALL EXTERIOR 8" WALLS, PROVIDE A MINIMUM (1) #5 VERTICAL REBAR SPACED 32" ON FOR ALL EXTERIOR 8" WALLS, PROVIDE A MINIMUM (1) #5 VERTICAL REBAR SPACED 32" ON CENTER MAXIMUM, CONTINUOUSLY FROM SUPPORT TO SUPPORT. IN ADDITION PROVIDE (1) #5 REBAR EACH SIDE OF EACH OPENING AND AT ENDS OF WALLS. ALSO, MAKE THESE BARS CONTINUOUS FROM SUPPORT TO SUPPORT. - FOR ALL WALLS, PROVIDE A MINIMUM OF (1) #5 HORIZONTAL BAR AT BOTTOM AND TOP OF FOR ALL WALLS, PROVIDE A MINIMUM OF (1) #5 HORIZONTAL BAR AT BOTTOM AND TOP OF WALL OPENINGS. BARS ARE TO EXTEND NOT LESS THAN 24 INCHES PAST THE OPENING. - INSTALL STANDARD WEIGHT (W1.7) LADDER TYPE HORIZONTAL JOINT REINFORCING AT INSTALL STANDARD WEIGHT (W1.7) LADDER TYPE HORIZONTAL JOINT REINFORCING AT MAXIMUM SPACING OF 16" ON-CENTER WHERE TWO LONGITUDINAL WIRES ARE USED. THE SPACES BETWEEN THESE WIRES SHALL BE THE WIDEST THAT THE MORTAR JOINT WILL ACCOMMODATE. INSTALL JOINT REINFORCING CONTINUOUS IN ALL SUCH JOINTS. LAP JOINT REINFORCING ACCORDING TO MANUFACTURER SPECIFICATIONS. JOINT REINFORCING SHALL CONSIST OF AT LEAST (2) TWO LONGITUDINAL WIRES FOR WALLS GREATER THAN 4 INCHES IN WIDTH AND AT LEAST (1) ONE WIRE FOR WALLS NOT EXCEEDING 4 INCHES IN WIDTH. - AT TOPS OF ALL 8" & 12" CMU WALLS AND AT A VERTICAL SPACING NOT TO EXCEED 48" AT TOPS OF ALL 8" & 12" CMU WALLS AND AT A VERTICAL SPACING NOT TO EXCEED 48" ON CENTER PROVIDE A CONTINUOUS BOND BEAM (KNOCK-OUT) CONTAINING (2) #5 LONGITUDINAL BARS. PLACE BARS AT TOP OF BOND BEAM. PROVIDE MINIMUM COVER OF 1 1/2" (ONE AND A HALF INCHES). FOR 6" WALLS PROVIDE CONTINUOUS BOND BEAM WITH (1) #5 LONGITUDINAL BAR. 15. REFER TO TYPICAL DETAILS FOR ADDITIONAL REINFORCING REQUIREMENTS AT WALL OPENINGS, REFER TO TYPICAL DETAILS FOR ADDITIONAL REINFORCING REQUIREMENTS AT WALL OPENINGS, CONTROL JOINTS, CORNERS, INTERSECTIONS, AND BEARING CONDITIONS FOR LINTELS, BEAMS, & COLUMNS. 16.