The provided document is a set of design and construction plans for the renovation of the Traverse City National Guard Armory in Michigan. The Department of Military and Veterans Affairs, State of Michigan is overseeing this project. The renovation involves demolition and reconstruction of various interior spaces including a lactation room, latrines, and storage areas. The plans detail the new floor layouts, wall and ceiling construction, roofing work, and mechanical/plumbing requirements. Key project details include reusing existing gutters and downspouts where possible, installing new asphalt shingles, EPDM membrane roofing, and upgrading the suspended ceiling system. Bidders will need to coordinate with the mechanical and electrical contractors throughout the project.

The contract opportunity associated with these plans is solicitation 511/22390 for the "Traverse City Armory - Renovate Armory" project. The solicitation is open to all interested bidders in the Grand Traverse County and Troy City, Michigan areas. Bidders must upload all attachments to the SIGMA VSS system, and are not to submit hardcopies. The bid deadline is 2:00pm on the due date. Award and contract term details are not provided in the plans.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D E

P A

R T

M E

N T

O

F

M

I L

I T

A R

Y

A

V

T

E R

A N

S

A

F F

A I R

S

S T

A T

E

O

F

M

I C

H I G

A N

D E

S I G

N

A

C

N

S T

R U

C T

I O

N

D

I V

I S

I O

N

C

A

A U

G

A

R E

N O

V A

A

R M

O R

Y

T R

A V

E R

S

I

Y

T

I O

N A

L

G

U A

M

O

A

V E

R S

E

C

I T

Y

M

I C

H I G

A N

STORAGE BLDG. FLOOR PLAN

SCALE 1/4" = 1'-0"

A1

STORAGE BLDG. ELEVATION

SCALE 1/4" = 1'-0"

A1

(TYPICAL)

NEW GRADE

w/6x6x#6Wx#6W WWF

CLASS II SAND

MINIMUM 6"

8"

6" CONCRETE FLOOR

M

I N

BUILDING

FACE

IN BACKGROUND

CONC. PEIR FOOTING

FOOTING

24" TURN-DOWN

E

(DESIGN BY BLDG

MFG.)

TOPSOIL/ORGANIC

CUT & REMOVE

MATERIAL, BACK-

FILL CLASS II

SAND

BARRIER

8 MIL. VAPOR

STORAGE BLDG. FOOTING

SCALE N.T.S.

A1

N

E

W

S

AutoCAD SHX Text

GRADE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

7'W X 8'H STEEL, INSULATED, ROLL UP DOOR, 4 TOTAL

AutoCAD SHX Text

3'-0" X 7'-0" X 1 " 34" H.M. DOOR, 4 TOTAL

AutoCAD SHX Text

WIRE MESH PARTITION FLOOR TO CEILING, 3 PLACES

AutoCAD SHX Text

BOLLARD, 8 TOTAL, SEE DETAIL E, SHT. C5

AutoCAD SHX Text

6" CONCRETE WITH 6X6 W1.4 X W1.4 WWF

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH, RA, DIRECTOR

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

WOMENS

294SF

DISTANCE

LEARNING

619SF

FIRE

68SF

ADMIN

876SF

MENS

285SF

STOR

48SF

BREAK/

VENDING

494SF

RECRUITING

255SF

VESTIBULE

211SF

MAIL

90SF

IT

48SF

CLASSROOM

751SF

TRAINING

AIDE

139SF

LOBBY

1040SF

MP CO

READINESS

208SF

TRAINING

140SF

ADMIN

140SF

PASSAGE

39SF

COORIDOR

1630SF

UP

STAIRWELL

LACT

92SF

FD

DEMOLITION FLOOR PLAN

FIRST FLOOR

SCALE 3/32" = 1'-0"

FLOOR PLAN -

LOCATION PLAN

SCALE 1/64" = 1'-0"

NEW LACTATION ROOM

AND LATRINE REMODEL

AREA

FEC

A010

A010

D E

P A

R T

M E

M

I L

I T

A R

Y

A

T

E R

A N

S

A

F F

A I R

S

S T

A T

E

O

F

M

I C

H I G

A N

D E

S I G

N

A

N

S T

R U

C T

I O

N

D

I V

I S

I O

N

C

A

A

A

R E

N O

V A

M

O R

Y

T R

A V

E R

T

I O

N A

L

G

U A

M

O

A

V E

R S

E

C

I T

Y

M

I C

H I G

A N

DEMOLITION FLOOR PLAN

FIRST FLOOR

SCALE 1/2" = 1'-0"

A010

WOMENS

294SF

MENS

285SF

IT

48SF

STOR

48SF

PASSAGE

39SF

DEMOLITION WORK AND QUANTITIES SHALL BE ACCOUNTED FOR FOLLOWING THE

RECYCLING PROGRAM LISTED IN THE SPECIFICATIONS.

COORDINATE THE REMOVAL OF THE EXISTING SUSPENDED CEILING TILE ASSEMBLY AND

FLOORING IN THOSE AREAS DESIGNATED TO BE REMODELED. COORDINATE WITH THE

OTHER DEMO PLANS AND THE FINISH DRAWINGS, DETAILS AND SCHEDULES.

IN ALL AREAS (FLOORS, WALLS, CEILINGS) WHERE CABINETS, COUNTERS, ANCHORS,

HANGERS, ETC., HAVE BEEN SPECIFIED TO BE REMOVED; PATCH, PAINT, REPLACE

COVERINGS WITH LIKE, MATCHING FINISHES, BLENDING THESE NEW EXPOSED AREAS INTO

EXISTING AREAS.

SEE FINISH SCHEDULE, FINISH DETAILS AND FINISH PLANS FOR ADDITIONAL CEILING AND

FLOORING DEMOLITION WORK.

GENERAL DEMOLITION NOTES:

REMOVE LAY IN TILE CEILING SYSTEM, LIGHT FIXTURES, DIFUSSERS, RETURN GRILLES AND ALL OTHER ITEMS IN THE CEILING SYSTEM THROUGHOUT

ENTIRE ROOM. PROTECT EXISTING FIRE PROTECTION OTHER ITEMS TO REMAIN. PREP FOR NEW CEILING. COORDINATE WITH PLUMBING, MECHANICAL, AND ELECTRICAL CONTRACTORS.

REMOVE EXISTING VCT FLOORING AND BASE THROUGHOUT ROOM. PREP FOR NEW FLOORING.

REMOVE EXISTING VCT FLOORING AND BASE AS NEEDED TO CONSTRUCT NEW ROOM. PREP FOR NEW FLOORING.

REMOVE EXISTING LAY IN CEILING IN AREA THAT WILL HAVE BE PART OF NEW ROOM. MODIFY EXISTING LAY IN CEILING TO ATTACH TO NEW WALL.

REMOVE EXISTING STUD WALL AND GYPSUM WALL BOARD.

REMOVE ALL EXISTING TOILET AND URINAL PARTITIONS .

REMOVE EXISTING TOILETS. PROTECT COLD WATER FEED AND SANITARY SEWER CONNECTION FOR REUSE. COORDINATE WITH PLUMBING

CONTRACTOR.

REMOVE EXISTING URINALS. PROTECT COLD WATER FEED AND SANITARY SEWER CONNECTION FOR REUSE. COORDINATE WITH PLUMBING

CONTRACTOR.

REMOVE EXISTING TOILET PAPER HOLDERS, GRAB BARS, PAPER TOWEL DISPENSERS, MIRRORS, ETC.

REMOVE EXISTING COUNTER TOP AND LAVATORIES. PROTECT COLD AND HOT WATER FEEDS AND SANITARY SEWER CONNECTION. COORDINATE

WITH PLUMBING CONTRACTOR.

SAWCUT CONCRETE FLOOR TO RELOCATE SANITARY DRAINS FOR NEW LAVATORY LOCATIONS..

DEMOLITION NOTES:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 147C

AutoCAD SHX Text 147B

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH, RA, DIRECTOR

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

WOMENS

294SF

DISTANCE

LEARNING

619SF

FIRE

68SF

ADMIN

876SF

MENS

285SF

STOR

48SF

BREAK/

VENDING

494SF

RECRUITING

255SF

VESTIBULE

211SF

MAIL

90SF

IT

48SF

CLASSROOM

751SF

TRAINING

AIDE

139SF

LOBBY

1040SF

MP CO

READINESS

208SF

TRAINING

140SF

ADMIN

140SF

PASSAGE

39SF

COORIDOR

1630SF

UP

STAIRWELL

LACT

92SF

6'-0"

11"

1'-0

3 4

1'-10

5'-3"

2'-1"

WM1

PTD

EHD

WC

UR

SND

TPD

LAV

EHD

TPD

TPD

TPD

TPD TPD

TPD

TPD

PTD

PTD

PTD

WC

WC

WC

WC

WC

WC

WC

WC

UR

UR

LAV

LAV

LAV

S.S. SPLASH PLATE; SEE

DETAIL FOR SIZE AND

MOUNTING HEIGHT

S.S. SPLASH PLATE; SEE

DETAIL FOR SIZE AND

MOUNTING HEIGHT

WM1

WM1

WM1

WM1

WM1

WM1

WM1

WM1

WM1

WM1

WM1

ONE PIECE COUNTER,

SINKS & BACK SPLASH

ONE PIECE COUNTER,

SINKS & BACK SPLASH

ONE PIECE COUNTER,

SINKS & BACK SPLASH

ONE PIECE COUNTER,

SINKS & BACK SPLASH

TPD SND

SND

SND

SND

1 2

SK-1

FD FD

FD FD

GB

GB

GB

GB

GB

GB

A300

A

A300

C

A300

B

A300

D

NEW LATRINE PLAN

FIRST FLOOR

SCALE 3/32" = 1'-0"

INSTALL NEW DOOR AND FRAME IN NEW OPENING.

INSTALL NEW 3-5/8" ST20 STEEL STUD WALL WITH 5/8" TYPE X

MR GYPSUM WALLBOARD WITH BATT INSULATION TO

UNDERSIDE OF EXISTING TRUSS; NEW WALL MAY CONTAIN A

NEW DOOR AND FRAME; STUDS TO BE 16" O.C.

INSTALL NEW 3-5/8" ST20 STEEL STUD WALL WITH 5/8" TYPE X

GYPSUM WALLBOARD WITH BATT INSULATION TO UNDERSIDE

OF EXISTING TRUSS; NEW WALL MAY CONTAIN A NEW DOOR

AND FRAME; STUDS TO BE 16" O.C.

PATCH EXISTING WALL WHERE EXISTING WALL/CEILING WERE

REMOVED.

FLOOR PLAN -

LOCATION PLAN

SCALE 1/64" = 1'-0"

NEW LACTATION ROOM

AND LATRINE REMODEL

AREA

FEC

A100

PATCH ALL WALLS WHERE EXISTING ABUTTING GYPSUM WALLBOARD WALLS AND CEILINGS WHERE

REMOVED.

PATCH ALL WALLS WHERE EXISTING EQUIPMENT, WALL HOOKS, ANCHORS, FASTENERS WERE

REMOVED; PREP FOR PAINTING AS SPECIFIED.

A100

GENERAL NOTES:

LEGEND:

D E

P A

R T

M E

M

I L

I T

A R

Y

A

T

E R

A N

S

A

F F

A I R

S

S T

A T

E

O

F

M

I C

H I G

A N

D E

S I G

N

A

N

S T

R U

C T

I O

N

D

I V

I S

I O

N

C

A

A

A

R E

N O

V A

M

O R

Y

T R

A V

E R

T

I O

N A

L

G

U A

M

O

A

V E

R S

E

C

I T

Y

M

I C

H I G

A N

NEW LATRINE DETAIL PLAN

FIRST FLOOR

SCALE 1/2" = 1'-0"

A100

WOMENS

294SF

INSTALL NEW 3-5/8" ST20

STEEL STUD 16" O.C. WALL

WITH 5/8" TYPE X MR

GYPSUM WALLBOARD

BOTH SIDES

MENS

285SF

IT

48SF

STOR

48SF

RECRUITING

255SF

PASSAGE

39SF

LACT

92SF

INSTALL NEW 3-5/8" ST20

STEEL STUD 16" O.C. WALL

WITH 5/8" TYPE X MR

GYPSUM WALLBOARD

BOTH SIDES

NOTES:

ACCESSORY SUPPORTS - ANY

FIXTURE OR ACCESSORY TO BE

HUNG ON THE GYPSUM WALL,

SHALL HAVE 2 X MEMBERS

SECURELY INSTALLED IN THE

STUD SPACE PRIOR TO GYPSUM

BOARD INSTALLATION; TO BE

INSTALLED IN THE LOCATION OF

THE MOUNTING ANCHORS.

WALL MIRRORWM1

PLUMBING FIXTURE

NOMENCLATURE

FIXTURE ITEM

LAVATORY

WATER CLOSET; FLOOR MOUNTED

FLOOR DRAIN

LAV

WC

MARK

FD

SK-1 LACTATION ROOM SS SINK

PAPER TOWEL DISPENSERPTD

TISSUE PAPER DISPENSERTPD

ELECTRIC HAND DRYEREHD

SANITARY NAPKIN DISPOSALSND

STAINLESS STEELS.S.

URINAL; WALL MOUNTEDUR

GRAB BARGB

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 147C

AutoCAD SHX Text 147B

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH, RA, DIRECTOR

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TOILET

PARTITION

TOILET

PARTITION

TPD TPD

WC WC

T

Y P

TOILET

PARTITION

TPD

WC

TOILET

PARTITION

TPD

WC

TOILET

PARTITION

TPD

WC WC

TOILET

PARTITION

TPD

3'-0"

GB

GB

GB

SUSPENDED CEILING TILE

SYSTEM

(2) LAYERS OF 5/8" TYPE X

GYPSUM WALLBOARD

PRE-ENGINEERED WOOD

TRUSSES 2'-0" O.C.

WALL BASE

T

Y P

SND SNDSND SND SND

SND

1'-5

3'-0"

1'-9"

DB18

SK-1

SB24

POSTFORMED

COVE LAMINATE

COUNTERTOP

GFI RECPT

PTD

CABINET

FINISHED

END PANEL

DB18

POSTFORMED COVE

LAMINATE

COUNTERTOP

5/16" RED OAK

OGEE EDGE

3/16" R

5/16" RED OAK OGEE EDGE

BASE CABINET

WALL

LACTATION AREA CABINET

COUNTER SECTION

SCALE 1 1/2" = 1'-0"

CONTINUOUS BEAD OF CAULK

INTERGAL 3" HIGH COVED BACKSPLASH

1'-11"2'-6"

FRONT APRON

OVERALL DISTANCE VARIES BASED ON LOCATION

LEFT SIDE

SPLASH

COORDINATE FAUCET

CENTERSET

RIGHT SIDE

APRON

Intregal

Bowl

*SEAM KIT TO BE COUNTER MANUFACTURER'S; SEAM

WORK TO BE INSTALLED BY SOLID SURFACE QUALIFIED

INSTALLER APPROVED BY COUNTER MANUFACTURER;

SEAM(s) TO BE APPROVED ON SITE BY

MANUFACTURER'S REPRESENTATIVE AND LETTER OF

ACCEPTANCE

COUNTER'S S.S. HEAVY DUTY WALL BRACKETS, TYPE

AND QUANTITY, SHALL BE COUNTER MANUFACTURER

SPECIFIED

SIDE VIEW

TOP VIEW

CONTINUOUS BEAD OF CAULK

1'-10"

1 2

1'-11"

SOLID SURFACE ONE PIECE

BACK SPLASH, APRON,

COUNTER AND SINK

**COORDINATE COUNTER'S S.S. HEAVY

DUTY WALL BRACKETS WITH THE

INSTALLATION OF PLUMBING PIPING

SUSPENDED CEILING TILE

SYSTEM

(2) LAYERS OF 5/8" TYPE X

GYPSUM WALLBOARD

PRE-ENGINEERED WOOD

TRUSSES 2'-0" O.C.

WALL BASE

8'-11"

M

A X

PTD

EHD

2'-0"

MIR1

2'-0" X 3'-0"

WALL

MIRROR

MIR1

2'-0" X 3'-0"

WALL

MIRROR

MIR1

2'-0" X 3'-0"

WALL

MIRROR

9'-0"

MIR1

2'-0" X 3'-0"

WALL

MIRROR

MIR1

2'-0" X 3'-0"

WALL

MIRROR

MIR1

2'-0" X 3'-0"

WALL

MIRROR

PTD

LAV

LAV

2'-0" 2'-6"

2'-0"

LIGHT FIXTURE

LIGHT FIXTURE LIGHT FIXTURE

TOILET

PARTITION

TPD

WC

TOILET

PARTITION

TPD

WCWC

TOILET

PARTITION

TPD

3'-0"

GB

GB

GB

SUSPENDED CEILING TILE

SYSTEM

(2) LAYERS OF 5/8" TYPE X

GYPSUM WALLBOARD

PRE-ENGINEERED WOOD

TRUSSES 2'-0" O.C.

WALL BASE

T

Y P

1'-5

3'-0"

1'-9"

UR UR UR

1 2

24" X 42"

URINAL

SCREEN

FLOOR MOUNTED

OVERHEAD

BRACED

SUSPENDED CEILING TILE

SYSTEM

(2) LAYERS OF 5/8" TYPE X

GYPSUM WALLBOARD

PRE-ENGINEERED WOOD

TRUSSES 2'-0" O.C.

WALL BASE

2'-6"

M

A X

PTD

EHD

MIR1

2'-0" X 3'-0"

WALL

MIRROR

MIR1

2'-0" X 3'-0"

WALL

MIRROR

MIR1

2'-0" X 3'-0"

WALL

MIRROR

PTD

LAV

1'-11"

LIGHT FIXTURE

MIR1

2'-0" X 3'-0"

WALL

MIRROR

MIR1

2'-0" X 3'-0"

WALL

MIRROR

MIR1

2'-0" X 3'-0"

WALL

MIRROR

LAV

LIGHT FIXTURE

2'-0"

S.S. SPLASH PLATE;

INSTALL BEHIND HAND

DRYER AS SHOWN

16'-5"

LACTATION AREA CABINETS

SCALE 1/2" = 1'-0"

LATRINE COUNTER DETAILS

SCALE 3/4" = 1'-0"

A

A300

PARTIAL WOMENS LATRINE ELEVATION

SCALE 3/8" = 1'-0"

G

A300

F

A300

E

A300

D E

P A

R T

M E

M

I L

I T

A R

Y

A

T

E R

A N

S

A

F F

A I R

S

S T

A T

E

O

F

M

I C

H I G

A N

D E

S I G

N

A

N

S T

R U

C T

I O

N

D

I V

I S

I O

N

C

A

A

A

R E

N O

V A

M

O R

Y

T R

A V

E R

T

I O

N A

L

G

U A

M

O

A

V E

R S

E

C

I T

Y

M

I C

H I G

A N

B

A300

PARTIAL WOMENS LATRINE ELEVATION

SCALE 3/8" = 1'-0"

C

A300

PARTIAL MENS LATRINE ELEVATION

SCALE 3/8" = 1'-0"

D

A300

PARTIAL MENS LATRINE ELEVATION

SCALE 3/8" = 1'-0"

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH, RA, DIRECTOR

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

P A

R T

M E

M

I L

I T

A R

Y

A

T

E R

A N

S

A

F F

A I R

S

S T

A T

E

O

F

M

I C

H I G

A N

D E

S I G

N

A

N

S T

R U

C T

I O

N

D

I V

I S

I O

N

C

A

A

A

R E

N O

V A

M

O R

Y

T R

A V

E R

T

I O

N A

L

G

U A

M

O

A

V E

R S

E

C

I T

Y

M

I C

H I G

A N

ROOF DEMO PLAN

SCALE 3/32" = 1'-0"

DS

DOWN SPOUT

WALK PAD

ROOF C ROOF A ROOF D

ROOF B

ROOF F

ROOF G

VTR

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS DS DS DS DS DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

DS

SHINGLES

SLOPE 3 : 12

SHINGLES

SLOPE 3 : 12

EPDM

MEMBRANE

EPDM

MEMBRANE

SHINGLES

SLOPE 3 : 12

SHINGLES

SLOPE 3 : 12

SHINGLES

SLOPE 3 : 12

SHINGLES

SLOPE 3 : 12

SHINGLES

SLOPE 3 : 12

EPDM MEMBRANE

SLOPE 1/4 : 12

EPDM MEMBRANE

SLOPE 1/4 : 12

EPDM MEMBRANE

SLOPE 1/4 : 12

EPDM MEMBRANE

SLOPE 1/4 : 12

EXTERIOR WALL OUTLINE

EXTERIOR

WALL OUTLINE

EXTERIOR WALL OUTLINE

EXTERIOR WALL OUTLINE

EXTERIOR WALL OUTLINE

S

L

O

P

E

S

L

O

P

E

COVERED PORCH OUTLINE

S L O

P E

EXISTING BUILDING ROOF ASSEMBLIES

THE EXISTING ROOF SYSTEMS/ASSEMBLIES ARE FROM INFORMATION LISTED ON THE

ORIGINAL BUILDING PLANS. ALL INFORMATION SHALL BE VERIFIED IN THE FIELD.

THERE ARE NO CURRENT WARRANTIES ON THE EXISTING ROOF SYSTEMS.

ROOF A:

PRE-ENGINEERED WOOD TRUSSES @ 2'-0" O.C.

5/8" PLYWOOD SHEATHING

2 LAYERS OF ROOFING FELT

ASPHALT SHINGLES

ROOF B: VULCRAFT 1.5B 20 GA PAINTED STEEL DECK

3" RIGID POLYISOCYANURATE INSULATION R-22

60 MIL EPDM ROOFING

ROOF C & D:

PRE-ENGINEERED WOOD TRUSSES @ 2'-0" O.C.

5/8" PLYWOOD SHEATHING

2 LAYERS OF ROOFING FELT

ASPHALT SHINGLES

FLAT AREA:

1/4 : 12 SLOPE

3" MIN TAPERED RIGID POLYISOCYANURATE INSULATION R-22

60 MIL EPDM ROOFING

S

L

O

P

S L O

S L O

S

L

O

EXTERIOR WALL

OUTLINE

VTR

LEGEND:

RS RS RS

RS RS RS

RS

RS

S L O

S T

E E

L

D

E C

K

S

L O

P E

S

SLOPE 1/4 : 12

STEEL DECK SLOPES

S L O

S T

E E

L

D

E C

K

S

L O

P E

S

CU-7

CU-6

CU-1

CU-5

CU-3

CU-4

RTU-3RTU-2

RTU-1

EXHAUST

EXHAUST

EXHAUST

EXHAUST

EXHAUST

EXHAUST EXHAUST

EXHAUST

EXHAUST

EXHAUST

VTR

VTR

ROOF

PEAK

ROOF

PEAK

ROOF

PEAK

ROOF

PEAK

A700

VTR VTR

REMOVE WALK PADS

AS SHOWN (TYPICAL)

VTR

REMOVE GUTTER AND

DOWNSPOUTS ALONG

ENTIRE LENGTH OF ROOF

REMOVE GUTTER AND

DOWNSPOUTS ALONG

ENTIRE LENGTH OF ROOF

ROOF A: ABOUT 3,110 SQ FT

ROOF B: ABOUT 11,346 SQ FT

ROOF C: ABOUT 8,333 SQ FT

ROOF D: ABOUT 4,805 SQ FT

ROOF A: REMOVE ASPHALT SHINGLES AND 2 LAYERS OF TAR PAPER AND ALL METAL

FLASHING

ROOF B: REMOVE 60 MIL EPDM ROOFING AND 3" OF RIGID POLYISOCYANURATE

INSULATION AND METAL COPINGS, FLASHING

ROOF C: REMOVE ASPHALT SHINGLES AND 2 LAYERS OF TAR PAPER AND METAL VENT

AND FLASHING

ON FLAT AREA REMOVE 60 MIL EPDM ROOFING AND 3" TAPERED RIGID

POLYISOCYANURATE INSULATION AND METAL FLASHING

ROOF D: REMOVE ASPHALT SHINGLES AND 2 LAYERS OF TAR PAPER AND METAL VENT

AND FLASHING

ON FLAT AREA REMOVE 60 MIL EPDM ROOFING AND 3" TAPERED RIGID

POLYISOCYANURATE INSULATION AND METAL FLASHING

ROOF F NOT IN CONTRACT

ROOF G NOT IN CONTRACT

VTR

ROOF DEMO PLAN NOTES:

· THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN ON THE ROOF PLANS AND DETAILS, AND SHALL BE RESPONSIBLE FOR THEM.

· CERTAIN NEW/EXISTING MECHANICAL ROOF EQUIPMENT AND ITEMS, i.e. STACKS, SUMPS, VENTILATORS, AIR INTAKES, EXHAUST UNITS, AND ETC. ARE SHOWN. THE CONTRACTOR SHALL

VISIT THE SITE AND INSPECT THE ROOF AREA(s) TO VERIFY THE EXACT SIZE, LOCATION, QUANTITY, AND TYPE OF EQUIPMENT SHOWN AND/OR NOT SHOWN THAT MUST BE FLASHED, SEALED, REMOVED, REINSTALLED, ETC., AND ASSUME FULL RESPONSIBILITY FOR THEIR

QUANTITIES.

· CERTAIN NOTES ARE REFERENCED ON THE ROOF PLAN AND DETAILS. THE CONTRACTOR

SHALL VISIT SITE TO INSPECT THE JOB AND DETERMINE OTHER LOCATIONS WHERE THAT SAME

WORK IS REQUIRED AND NOT SO REFERENCED.

REMOVE GUTTER AND

DOWNSPOUTS ALONG

ENTIRE LENGTH OF ROOF

(NOT IN CONTRACT)

REMOVE VENT AND

FLASHING ALONG ENTIRE

LENGTH OF ROOF

(NOT IN CONTRACT)

REMOVE VENT AND

FLASHING

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH, RA, DIRECTOR

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

P A

R T

M E

M

I L

I T

A R

Y

A

T

E R

A N

S

A

F F

A I R

S

S T

A T

E

O

F

M

I C

H I G

A N

D E

S I G

N

A

N

S T

R U

C T

I O

N

D

I V

I S

I O

N

C

A

A

A

R E

N O

V A

M

O R

Y

T R

A V

E R

T

I O

N A

L

G

U A

M

O

A

V E

R S

E

C

I T

Y

M

I C

H I G

A N

ROOF PLAN

SCALE 3/32" = 1'-0"

REUSE EXISTING GUTTERS

AND DOWNSPOUTS (TYP.),

OTHERWISE INSTALL NEW

MATCHING EXISTING SIZE

AND COLOR

DS

ROOF SUMP

DOWN SPOUT

WALK PAD

ROOF C ROOF A ROOF D

ROOF B

ROOF F

ROOF G

VTR

DS

DS

DS

DS

DS

DS

DS

DS

DS DS DS DS DS DS

DS

DS

DS

DS

DS

DS

DS

PAINT AREA TO MATCH EXISTING WHERE

REMOVED DOWNSPOUTS WERE LOCATED,

TYP.

SHINGLES

SLOPE 3 : 12

SHINGLES

SLOPE 3 : 12

EPDM

MEMBRANE

EPDM

MEMBRANE

SHINGLES

SLOPE 3 : 12

SHINGLES

SLOPE 3 : 12

SHINGLES

SLOPE 3 : 12

SHINGLES

SLOPE 3 : 12

SHINGLES

SLOPE 3 : 12

EPDM MEMBRANE

SLOPE 1/4 : 12

EPDM MEMBRANE

SLOPE 1/4 : 12

EPDM MEMBRANE

SLOPE 1/4 : 12

EPDM MEMBRANE

SLOPE 1/4 : 12

EXTERIOR WALL OUTLINE

EXTERIOR

WALL OUTLINE

EXTERIOR WALL OUTLINE

EXTERIOR WALL OUTLINE

EXTERIOR WALL OUTLINE

S

L

O

P

E

S

L

O

P

E

COVERED PORCH OUTLINE

S L O

P E

EXISTING BUILDING ROOF ASSEMBLIES

THE EXISTING ROOF SYSTEMS/ASSEMBLIES ARE FROM INFORMATION LISTED ON THE

ORIGINAL BUILDING PLANS. ALL INFORMATION SHALL BE VERIFIED IN THE FIELD.

THERE ARE NO CURRENT WARRANTIES ON THE EXISTING ROOF SYSTEMS.

ROOF A:

PRE-ENGINEERED WOOD TRUSSES @ 2'-0" O.C.

5/8" PLYWOOD SHEATHING

2 LAYERS OF ROOFING FELT

ASPHALT SHINGLES

ROOF B: VULCRAFT 1.5B 20 GA PAINTED STEEL DECK

3" RIGID POLYISOCYANURATE INSULATION R-22

60 MIL EPDM ROOFING

ROOF C & D:

PRE-ENGINEERED WOOD TRUSSES @ 2'-0" O.C.

5/8" PLYWOOD SHEATHING

2 LAYERS OF ROOFING FELT

ASPHALT SHINGLES

FLAT AREA:

1/4 : 12 SLOPE

3" MIN TAPERED RIGID POLYISOCYANURATE INSULATION R-22

60 MIL EPDM ROOFING

S

L

O

S L O

S L O

S

L

O

INSTALL NEW METAL

ROOF DIVERTER

INSTALL CRICKET AS

NEEDED

EXTERIOR WALL

OUTLINE

ROOF HATCH;

COORDINATE

ROOF HATCH

VTR

LEGEND:

RS RS RS

RS RS RS

RS

RS

S L O

S T

E E

L

D

E C

K

S

L O

P E

S

SLOPE 1/4 : 12

STEEL DECK SLOPES

S L O

S T

E E

L

D

E C

K

S

L O

P E

S

INSTALL TAPERED

INSULATION (TYP)

CU-7

CU-6

CU-1

CU-5

CU-3

CU-4

RTU-3RTU-2

RTU-1

EXHAUST

EXHAUST

EXHAUST

EXHAUST

EXHAUST

EXHAUST EXHAUST

EXHAUST

EXHAUST

EXHAUST

VTR

VTR

ALL NEW ROOF TOP EQUIPMENT SHALL BE INSTALLED ON CURBS AND FLASHED ACCORDING TO THE

ROOF SYSTEM MANUFACTURER'S INSTALLATION INSTRUCTIONS.

THE ROOFING CONTRACTOR SHALL COORDINATE WITH THE MECHANICALS FOR THE LOCATION OF

WALK PADS AT ALL ROOF TOP UNITS AND EQUIPMENT. UNLESS OTHERWISE NOTED OR SHOWN ON

THE ROOF PLAN, EACH UNIT SHALL HAVE A MINIMUM OF (4) WALK PADS AT THE UNITS IN THE AREAS

WHERE THEY WILL BE SERVICED.

INSTALL ROOFING WALK PADS AT EACH ROOF TOP MECHANICAL UNIT, AS WELL AS AT THE ROOF

HATCHES AS SHOWN ON THIS PLAN.

GENERAL NOTES:

A702

A702

ROOF

PEAK

ROOF

PEAK

ROOF

PEAK

ROOF

PEAK

BUILDING ADDITION ROOF PLAN NOTES:

· THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN ON THE ROOF PLANS AND DETAILS, AND SHALL BE RESPONSIBLE FOR THEM.

· THE PLANS AND DETAILS DO NOT SHOW A RECOVERY BOARD BETWEEN THE INSULATION AND

ROOFING MEMBRANE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL SUCH

MATERIAL IF THE ROOF MANUFACTURE THAT THE CONTRACTOR CHOOSES TO INSTALL

REQUIRES ONE FOR IT'S COMPLETE ROOF SYSTEM WARRANTY.

· CERTAIN NEW/EXISTING MECHANICAL ROOF EQUIPMENT AND ITEMS, i.e. STACKS, SUMPS, VENTILATORS, AIR INTAKES, EXHAUST UNITS, AND ETC. ARE SHOWN. THE CONTRACTOR SHALL

VISIT THE SITE AND INSPECT THE ROOF AREA(s) TO VERIFY THE EXACT SIZE, LOCATION, QUANTITY, AND TYPE OF EQUIPMENT SHOWN AND/OR NOT SHOWN THAT MUST BE FLASHED, SEALED, REMOVED, REINSTALLED, ETC., AND ASSUME FULL RESPONSIBILITY FOR THEIR

QUANTITIES.

· CERTAIN NOTES ARE REFERENCED ON THE ROOF PLAN AND DETAILS. THE CONTRACTOR

SHALL VISIT SITE TO INSPECT THE JOB AND DETERMINE OTHER LOCATIONS WHERE THAT SAME

WORK IS REQUIRED AND NOT SO REFERENCED.

· THE CONTRACTOR SHALL VERIFY ALL DETAILS AND SPECIAL CONDITIONS ON THE ROOF WITH

THE NEW SINGLE-PLY MEMBRANE ROOFING MANUFACTURER AND SHALL INCLUDE IN HIS

PROPOSAL AND BE RESPONSIBLE FOR ANY DEVIATIONS REQUIRED TO ANY AND ALL DETAILS

SHOWN AS REQUIRED TO MAINTAIN THE NEW TWENTY YEAR SYSTEM WARRANTY AS SPECIFIED.

DEVIATIONS MUST BE APPROVED BY THE DEPARTMENT OF MILITARY & VETERAN AFFAIRS.

· INSTALL A 1/2" RECOVERY BOARD IF DIRECTED BY ROOF MANUFACTURER. IF NEEDED THIS

SHALL BE INCLUDED IN THE BASE PROPOSAL SUM.

A701

NEW METAL

COPING

VTR VTR

INSTALL WALK PADS

AS SHOWN (TYPICAL)

4" RS

A702

A702

NEW ROOF SUMP

(TYPICAL)

RS

INSTALL TAPERED

INSULATION (TYP)

INSTALL TAPERED

INSULATION (TYP)

INSTALL TAPERED

INSULATION (TYP)

NEW ROOF SUMP

(TYPICAL)

NEW BUILDING ROOF ASSEMBLIES

ROOF A:

PRE-ENGINEERED WOOD TRUSSES @ 2'-0" O.C.

5/8" PLYWOOD SHEATHING

NEW 2 LAYERS OF ROOFING SYNTHETIC UNDERLAYMENT

NEW SELF ADHERING ICE AND WATER SHIELD, WHERE SHOWN ON DRAWING

NEW ASPHALT SHINGLES

ROOF B: VULCRAFT 1.5B 20 GA PAINTED STEEL DECK

NEW 5" RIGID POLYISOCYANURATE INSULATION

NEW TAPER INSULATION

NEW 60 MIL FULLY ADHERED PVC OR EPDM MEMBRANE

NEW METAL FASCIA

ROOF C & D:

PRE-ENGINEERED WOOD TRUSSES @ 2'-0" O.C.

5/8" PLYWOOD SHEATHING

NEW 2 LAYERS OF ROOFING SYNTHETIC UNDERLAYMENT

NEW SELF ADHERING ICE AND WATER SHIELD, WHERE SHOWN ON DRAWING

NEW ASPHALT SHINGLES

FLAT AREA:

1/4 : 12 SLOPE

NEW 5" RIGID POLYISOCYANURATE INSULATION

NEW 60 MIL FULLY ADHERED PVC OR EPDM MEMBRANE

4" RS

4" RS

4" RS

4" RS

4" RS

A702

PAINT AREA TO MATCH EXISTING WHERE

REMOVED DOWNSPOUTS WERE LOCATED,

TYP.

NOT IN CONTRACT

NEW ICE AND WATER

SHIELD TO THIS LINE, 2'

FROM EXTERIOR WALL

NEW ICE AND WATER

SHIELD TO THIS LINE, 2'

FROM EXTERIOR WALL

NEW ICE AND WATER

SHIELD TO THIS LINE, 2'

FROM EXTERIOR WALL

NEW ICE AND WATER

SHIELD TO THIS LINE, 2'

FROM EXTERIOR WALL

A702

CONTINUOUS FLASHING

AT WALL/ROOF

CONTINUOUS FLASHING

AT WALL/ROOF

CONTINUOUS VENT AND

FLASHING ALONG ENTIRE

LENGTH

CONTINUOUS VENT AND

FLASHING ALONG ENTIRE

LENGTH

NOT IN CONTRACT

RIDGE VENT

VTR

REUSE EXISTING GUTTERS

AND DOWNSPOUTS (TYP.),

OTHERWISE INSTALL NEW

MATCHING EXISTING SIZE

AND COLOR

CONTINUOUS FLASHING

AT MEMBRANE/SHINGLE

TRANSITION (TYP.)

CONTINUOUS FLASHING

AT MEMBRANE/SHINGLE

TRANSITION (TYP.)

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH, RA, DIRECTOR

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

ELEV 12'-0" A.F.F. OR 820.6

EX. 6" WOOD STUDS, 16" O.C.

EX. EXTERIOR FINISH SYSTEM

(E.I.F.S.) WITH 5/8" PLYWOOD

SHEATHING AND 1" POLYSTYRENE

INSULATION

EX. 5-1/2" R-20 BATT

INSULATION

EX. 5/8" TYPE X GYPSUM

BOARD OVER 6 MIL VAPOR

BARRIER

EX. SUSPENDED CEILING

TILE SYSTEM

EX. (2) LAYERS OF 5/8" TYPE

X GYPSUM WALLBOARD

EX. PRE-FINISHED GUTTER AND

DOWNSPOUT

EX. (2)2X6 TOP PLATE

EX. PRE-ENGINEERED WOOD

TRUSSES 2'-0" O.C.

EX. 5/8" OSB SHEATHING

NEW ASPHALT SHINGLES

OVER NEW 2 LAYERS OF

SYNTHETIC UNDERLAYMENT

EX. CONTINUOUS

VENTED SOFFIT

EX. HIGH DENSITY FOAM

ADHERED TO SHEATHING

WITH E.I.F.S. FINISH

NEW ALUMINUM DRIP EDGE

ELEV 100.0 (808.6) (F.F.)

EX. R-38 INSULATION

2'-0"

NEW SELF ADHERING ICE AND

WATER SHIELD FROM DRIP

EDGE TO 2' PAST EXTERIOR

WALL

EXISTING 8" TILT UP

CONCRETE WALL

V A

R I E

S

V

A R

I E

S

EXISTING METAL ROOF

DECK

EXISTING 2 X 12 WOOD

BLOCKING

EXISTING 2 X 4 WOOD

BLOCKING

NEW 2 X 8 P.T. WOOD

BLOCKING ROOFING EDGE DETAIL

PER ROOFING

MANUFACTURER

RECOMMENDATION

NEW 60 MIL FULLY

ADHERED MEMBRANE

NEW 5.25" OF

INSULATION (R-30)

NEW TAPER

INSULATION

NEW ALUMINUM WRAP

NEW CAULKING ALONG

ENTIRE LENGTH

NEW METAL FASCIA

NEW CONTINUOUS

CLEAT

NEW 60 MIL FULLY

ADHERED MEMBRANE

30'-0" AFF

EX. METAL ROOF DECK

EX. (2) LAYERS OF 5/8" TYPE

X GYPSUM WALLBOARD

EXISTING

PRE-ENGINEERED

WOOD TRUSSES

2'-0" O.C.

EX. R-38 INSULATION

EX. SUSPENDED CEILING TILE

SYSTEM

34'-0" AFF

EX. 2 X 8 WOOD BLOCKING

EX. WOOD BLOCKING

NEW P.T. 2 X 4 WOOD

BLOCKING

NEW 5.25" OF INSULATION

(R-30)

NEW PAINTED GALVANIZED

STEEL COPING

NEW MEMBRANE SUB

FLASHING

NEW MEMBRANE

COUNTERFLASHING

NEW 60 MIL FULLY ADHERED

MEMBRANE

NEW CANT STRIP

NEW 60 MIL FULLY ADHERED

MEMBRANE

EX. STEEL JOIST

EX. STEEL BRACING

EX. CONCRETE TILT UP WALL

EX.

" WOOD DECKING

EX. EIFS SURFACE

EX. 2 X 4 WOOD BLOCKING

NEW 1 1/2" OF INSULATION

NEW CANT STRIP

ROOFING COPING DETAIL

PER ROOFING

MANUFACTURER

RECOMMENDATION

NEW 60 MIL FULLY ADHERED

MEMBRANE

NEW METAL COUNTER

FLASHING

ROOFING FLASHING DETAIL

PER ROOFING

MANUFACTURER

RECOMMENDATION

EX. HIGH DENSITY FOAM

DETAIL

30'-0" AFF

EX. (2) LAYERS OF 5/8" TYPE

X GYPSUM WALLBOARD

EXISTING

PRE-ENGINEERED

WOOD TRUSSES

2'-0" O.C.

EX. R-38 INSULATION

EX. SUSPENDED CEILING TILE

SYSTEM

EX. CONCRETE TILT UP WALL

EX. 5/8" WOOD DECKING

NEW METAL COUNTER

FLASHING

NEW ASPHALT SHINGLES

OVER NEW 2 LAYERS OF

SYNTHETIC UNDERLAYMENT

A702

NEW METAL VENT FOR

SLOPED ROOF TO WALL

TRANSITION

NEW 1/2" TAPERED INSULATION

NEW 60 MIL FULLY ADHERED MEMBRANE

NEW DRAIN

NEW DRAIN PAN

NEW 5.25" INSULATION

NEW PIPE INSULATION

NEW PIPE INSULATION

ENTIRE LENGTH

TO TURN DOWN TRANSITON

EXISTING METAL DECK

NEW 5.25" INSULATION

USE APPROVED PIPE HANGER

TO SUPPORT DRAIN PIPE

DRAINS SLOPE 1/8" PER FOOT (MIN)

NEW SCH 40 PVC DRAIN PIPE

ALL NEW PIPING UNDER DECK TO BE INSULATED

EDGE OF ROOF

SLOPE PER MANUFACTURER REQUIREMENT

M

I N

I M

U M

EXISTING SUPPLEMENTARY STEEL L FRAMING

NOTE:

INCLUDE SADDLES/CRICKETS SLOPING TO DRAINS AT 1/8"/FT. AT

MECHANICAL CURBS TO PROVIDE POSITIVE DRAINAGE TO THE ROOF

DRAINS.

EXISTING METAL ROOF DECK

ROOF INSULATION AS SPECIFIED

FOLD FLASHING OVER CURB AND FASTEN 8"

O.C. WITH SPECIFIED FASTENERS

NEW GALV INSULATED CURB AS REQUIRED TO PROVIDE

8" MINIMUM ROOFING MEMBRANE HEIGHT ABOVE

MEMBRANE SURFACE

60 MIL FULLY ADHERED ROOF MEMBRANE WITH

MANUFACTURER 20 YEAR SYSTEM WARRANTY

ADD TREATED WOOD BLOCKING AS NEEDED

PVC FASTENER AND PLATE, 12" O.C. MAX OR AS DIRECTED BY

ROOF MANUFACTURER

INSTALL NEW FLASHING MEMBRANE; ADHESIVE (BEHIND)

EXISTING METAL ROOF DECK

ROOF INSULATION AS SPECIFIED

NOTES:

- DO NOT CUT PREFABRICATED BOOT - PULL OVER VENT PIPE

- SIZE BOOT TO VENT PIPE USING SMALL (1"-4") OR LARGE (4"-8") DIAMTER BOOT

- INSTALL WATER-BLOCK SEALANT COURSE BETWEEN BOOT AND VENT PIPE PRIOR TO

INSTALLATION OF DRAW-BAND

- INSTALL CONTINUOUS SEALANT COURSE TO TOP OF DRAW-BAND FOLLOWING TIGHTENING

ONE PIECE BOOT

STAINLESS STEEL CLAMP

CONTINUOUS SEALANT

VENT STACK

60 MIL FULLY ADHERED EPDM ROOF MEMBRANE

WITH MANUFACTURER 20 YEAR SYSTEM WARRANTY

TREATED WOOD BLOCKING AS NEEDED

D E

P A

R T

M E

M

I L

I T

A R

Y

A

T

E R

A N

S

A

F F

A I R

S

S T

A T

E

O

F

M

I C

H I G

A N

D E

S I G

N

A

N

S T

R U

C T

I O

N

D

I V

I S

I O

N

C

A

A

A

R E

N O

V A

M

O R

Y

T R

A V

E R

T

I O

N A

L

G

U A

M

O

A

V E

R S

E

C

I T

Y

M

I C

H I G

A N

SECTION

SCALE 1/2" = 1'-0"

ALL ROOF TOP EQUIPMENT SHALL BE INSTALLED ON CURBS AND FLASHED ACCORDING TO THE

ROOF SYSTEM MANUFACTURER'S INSTALLATION INSTRUCTIONS.

THE ROOFING CONTRACTOR SHALL COORDINATE WITH THE MECHANICALS FOR THE LOCATION OF

WALK PADS AT ALL ROOF TOP UNITS AND EQUIPMENT. UNLESS OTHERWISE NOTED OR SHOWN ON

THE ROOF PLAN, EACH UNIT SHALL HAVE A MINIMUM OF (4) WALK PADS AT THE UNITS IN THE AREAS

WHERE THEY WILL BE SERVICED.

GENERAL NOTES:

ROOF PLAN NOTES:

· THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS SHOWN ON THE ROOF PLANS AND DETAILS, AND SHALL BE RESPONSIBLE FOR THEM.

· THE PLANS AND DETAILS DO NOT SHOW A RECOVERY BOARD BETWEEN THE INSULATION AND

ROOFING MEMBRANE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL SUCH

MATERIAL IF THE ROOF MANUFACTURE THAT THE CONTRACTOR CHOOSES TO INSTALL

REQUIRES ONE FOR IT'S COMPLETE ROOF SYSTEM WARRANTY.

· CERTAIN NEW/EXISTING MECHANICAL ROOF EQUIPMENT AND ITEMS, i.e. STACKS, SUMPS, VENTILATORS, AIR INTAKES, EXHAUST UNITS, AND ETC. ARE SHOWN. THE CONTRACTOR SHALL

VISIT THE SITE AND INSPECT THE ROOF AREA(s) TO VERIFY THE EXACT SIZE, LOCATION, QUANTITY, AND TYPE OF EQUIPMENT SHOWN AND/OR NOT SHOWN THAT MUST BE FLASHED, SEALED, REMOVED, REINSTALLED, ETC., AND ASSUME FULL RESPONSIBILITY FOR THEIR

QUANTITIES.

· CERTAIN NOTES ARE REFERENCED ON THE ROOF PLAN AND DETAILS. THE CONTRACTOR

SHALL VISIT SITE TO INSPECT THE JOB AND DETERMINE OTHER LOCATIONS WHERE THAT SAME

WORK IS REQUIRED AND NOT SO REFERENCED.

· THE CONTRACTOR SHALL VERIFY ALL DETAILS AND SPECIAL CONDITIONS ON THE ROOF WITH

THE NEW SINGLE-PLY MEMBRANE ROOFING MANUFACTURER AND SHALL INCLUDE IN HIS

PROPOSAL AND BE RESPONSIBLE FOR ANY DEVIATIONS REQUIRED TO ANY AND ALL DETAILS

SHOWN AS REQUIRED TO MAINTAIN THE NEW TWENTY YEAR SYSTEM WARRANTY AS SPECIFIED.

DEVIATIONS MUST BE APPROVED BY THE DEPARTMENT OF MILITARY & VETERAN AFFAIRS.

· INSTALL A 1/2" RECOVERY BOARD IF DIRECTED BY ROOF MANUFACTURER. IF NEEDED THIS

SHALL BE INCLUDED IN THE BASE PROPOSAL SUM.

A702

SECTION

SCALE 1 1/2" = 1'-0"

A702

SECTION

SCALE 1/2" = 1'-0"

A702

SECTION

SCALE 1/2" = 1'-0"

A702

ROOF SUMP

SCALE 1 1/2" = 1'-0"

A702

TYPICAL EQUIPMENT CURB

SCALE 1 1/2" = 1'-0"

A702

TYPICAL VENT STACK

SCALE 1 1/2" = 1'-0"

A702

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH, RA, DIRECTOR

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

ROOM FINISH SCHEDULE

ROOM NAMEROOM

NO.

FLOORS

MENS

WOMENS

LACTATION167

WALLS

NEW EXTG NEW EXTG NEW EXTG

CEILINGS

N S E W TYPETYPE

BASE

TYPE

CONSTRUCTION NOTES

NEW / EXTGHEIGHTNEW EXTG TYPE

ROOM

NO.

X VCT RVBX

RVBXX VCT

X GWB-X

PT PT PT PT

X GWB-X

PT PT PT PT

X 10'-0" SCT

X 10'-0" SCT

1., 2., 10., a.

1., 2., 10., a.

X VCT RVBX

X GWB-X

PT PT PT PT X 10'-0" SCT 1., 2., 10., a.

X

DOOR AND DOOR HARDWARE SCHEDULE

ROOM NAMEDOOR

NO.

DOOR

LACTATION

GENERAL PURPOSE STORAGE BLDG

HARDWARE SET

NEW MATL

FRAME

FINISH NEW MATL FINISH

X PAINT PAINTX

XX

18 G18 G

16 G GALV PAINT 16 G GALV

PAINT

GENERAL PURPOSE STORAGE BLDG89 XX

16 G GALV PAINT 16 G GALV

PAINT

GENERAL PURPOSE STORAGE BLDG90 XX

16 G GALV PAINT 16 G GALV

PAINT

GENERAL PURPOSE STORAGE BLDG91 XX

16 G GALV PAINT 16 G GALV

PAINT

TYPICAL MOUNTING

ADJACENT TO DOOR ON WALL

3 4

APPLY TO WALL w/

DOUBLE-STICK TAPE

LACTATION

ROOM

GENERAL NOTES:

1. MOUNT SIGN w/ CENTERLINE AT 4'-7 1/2" A.F.F.

3 4

1"

TACTILE LETTERING, 1" HELVETICA

MEDIUM TEXT, COLOR: WHITE.

BRAILLE LETTERING

TACTICAL LETTERING, 3/4"

HELVETICA MEDIUM TEXT,

COLOR: WHITE

(SIGN ROOM # LOCATION)

(SIGN MESSAGE LOCATION)

REFLECTED CEILING PLAN

LATRINES AND LACTATION ROOM

FIRST FLOOR

SCALE 1/2" = 1'-0"

REPLACE EXISTING DROP

CEILING WITH NEW IN

MENS LATRINE

COORDINATE WITH MECHANICAL AND ELECTRICAL FOR DIFFUSERS AND LIGHTING...

MATCH EXISTING TILE; TYPE, SIZE AND TEXTURE..

FIRE SUPPRESSION SPRINKLER HEADS ARE NOT SHOWN ON THIS PLAN. SEE SHEETS FP100

TO FP103, COORDINATE.

A900

GENERAL NOTES:

D E

P A

R T

M E

M

I L

I T

A R

Y

A

T

E R

A N

S

A

F F

A I R

S

S T

A T

E

O

F

M

I C

H I G

A N

D E

S I G

N

A

N

S T

R U

C T

I O

N

D

I V

I S

I O

N

C

A

A

A

R E

N O

V A

M

O R

Y

T R

A V

E R

T

I O

N A

L

G

U A

M

O

A

V E

R S

E

C

I T

Y

M

I C

H I G

A N

INSTALL NEW DROP

CEILING LACTATION ROOM

REPLACE EXISTING DROP

CEILING WITH NEW AND

MODIFY FOR ADJACENT

NEW ROOM IN WOMENS

LATRINE

a. COORDINATE ROOM FINISH SCHEDULE WITH NEW REFLECTED CEILING PLAN.

GENERAL VINYL BASE NOTE -

ROOMS GETTING NEW WALLS WHERE THE EXISTING FLOORING IS REMAINING AND

EXISTING VINYL BASE IS REMAINING, CONTRACTOR IS TO INSTALL NEW MATCHING

VINYL BASE ON THE NEW WALLS. IF A MATCH CANNOT BE FOUND, THE CONTRACTOR

IS TO REPLACE THE ENTIRE ROOM'S VINYL BASE, WITH NEW AS SPECIFIED.

EXISTING CEILINGS:

1. EXISTING ROOMS HAVE (2) LAYERS OF TYPE X GWB ATTACHED TO THE BOTTOM

CHORD OF THE WOOD TRUSSES. IT SHALL REMAIN.

2. REMOVE EXISTING GRID SYSTEM AND PREPARE FOR NEW

EXISTING FLOORING:

10. REMOVE EXISTING VCT AND WALL BASE AND PREPARE FLOORING FOR NEW.

EPOXY EPOXY FLOORING

GWB-MR GYPSUM WALL BOARD, MOISTURE RESISTANT; TAPED, FINISHED AND PAINTED

GWB-X GYPSUM WALL BOARD, TYPE X; TAPED, FINISHED AND PAINTED

PT PAINT

RVB RESILIENT VINYL BASE

SCT SUSPENDED CEILING TILE/METAL GRID ASSEMBLY

VCT VINYL COMPOSITE TILE

GENERAL NOTES:

LEGEND:

ROOM FINISH SCHEDULE

N.T.S.

A900

DOOR AND HARDWARE

SCHEDULE

N.T.S.

A900

ROOM SIGNAGE

N.T.S.

A900

REINSTALL EXISTING SIGN

INSTALL NEW ROOM SIGN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH, RA, DIRECTOR

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

AutoCAD SHX Text

KMM

26C6921023 Renovate Armory TC A001 Storage bldg
Sheets and Views
A1 STORAGE BLDG
26C6921023 Renovate Armory TC A010 Demo Plan
Sheets and Views
SHEET A010
26C6921023 Renovate Armory TC A100 Floor Plan
Sheets and Views
SHEET A100
26C6921023 Renovate Armory TC A300 Details
Sheets and Views
A300
26C6921023 Renovate Armory TC A700 Roof Demo Plan
Sheets and Views
A700 ROOF DEMO PLAN
26C6921023 Renovate Armory TC A701 Roof Plan
Sheets and Views
A701 ROOF PLAN
26C6921023 Renovate Armory TC A702 Roof Details
Sheets and Views
A702 ROOF DETAILS
26C6921023 Renovate Armory TC A900 Reflected Ceiling and Finish Plan
Sheets and Views
A900