26081 Napaskiak Distribution Upgrade ITB Drawings.pdf
PDF 2 MB Posted
- Attached to
- Napaskiak Distribution Upgrade Project Project
- Solicitation number
- 26081
- Issued by
- Aleutians East Borough, Badger CDP, Alaska
About this file
This document consists of technical drawings for the Napaskiak Distribution Upgrade Project, a Denali Commission and State appropriation-funded contract for the renovation and upgrade of an existing overhead electrical power distribution system in Napaskiak, Alaska. The project drawings include detailed specifications for pole installation, grading requirements, auger hole specifications, and backfill procedures, with multiple additive alternates (ADD ALT 1 through ADD ALT 4) identified through clouded work sections on various drawing sheets (E10.0, E10.1, E11.0 through E11.4, and E12.1 through E12.4). A non-mandatory pre-bid meeting was scheduled for May 28, 2026, at 10:00 AM to be conducted telephonically via conference line 1-469-810-0642, ID 214 800 089#. No mandatory site visit was scheduled prior to bid opening, though interested parties could contact Contract Officer Selwin C. Ray at (907) 771-3035 for additional information.
The contractor shall furnish all labor, materials, supervision, equipment, tools, transportation, quality control, and supplies required to complete the work as specified in the drawings. The pole installation specifications vary by height, with minimum ground clearance requirements of 7 feet for 35-foot poles, 8 feet for 40-foot poles, and 9 feet for 45-foot poles at final grade. Auger holes must have a minimum diameter of 3 feet with depths as indicated on plans, and backfill must be completed with gravel in maximum 8-inch lifts and compacted. The project is funded through Denali Commission and State appropriations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
O
ETATS
TH
A
AKSAL
F
E10.0
F
E10.1
POLE AS
INDICATED ON
THE PLANS &
STAKING SHEETS
FINAL
GRADE
7' M
IN
(3
5' P
O
LE
S
8' M
IN
(4
0' P
O
LE
S
9' M
IN
(4
5' P
O
LE
S
NOTES:
1. AUGER MINIMUM 3' DIAMETER HOLE, DEPTH AS INDICATED.
2. BACKFILL WITH GRAVEL AND COMPACT IN MAXIMUM 8" LIFTS.
E11.0
ETATS
E11.1
ETATS
ALL CLOUDED WORK ON
THIS SHEET IS ADD ALT 1
E11.2
ETATS
THIS SHEET IS ADD ALT 2
E11.3
ETATS
THIS SHEET IS ADD ALT 3
E11.4
ETATS
ALL WORK ON THIS
SHEET IS ADD ALT 4
E12.1
ETATS
THIS SHEET IS ADD ALT 1
E12.2
THIS SHEET IS ADD ALT 2
E12.3
THIS SHEET IS ADD ALT 3
E12.4
ETATS
ALL WORK ON THIS
SHEET IS ADD ALT 4
File details come from the government source that posted it. Updated .