26043-ITB- Manokotak Power Plant Upgrade Project Design Part 2.pdf

PDF 10 MB Posted

Attached to
Manokotak Power Plant Upgrade Project
Solicitation number
26043
Issued by
Dillingham Census Area, Alaska

About this file

This is a construction design document issued by the Alaska Energy Authority for the Manokotak Power Plant Upgrade Project. The project encompasses a complete renovation of an existing power plant in Manokotak, Alaska, including building renovation, installation of new owner-furnished generators, switchgear, and other equipment, replacement and renovation of mechanical and electrical systems, repair and expansion of a heat recovery system, and additional community improvements. The contractor is required to furnish all labor, materials, supervision, equipment, tools, transportation, quality control, and supplies necessary to complete the work. The document shows equipment specifications and control station details for 350 kilowatt generators manufactured by Controlled Power, Inc., with serial number 9332SG, including radiator fans, charge air coolers, and electrical switchgear configurations. A non-mandatory pre-bid meeting is scheduled for March 26, 2026, at 10:00 AM to be conducted telephonically at 1-469-810-0642 with Conference ID 215 116 149#. No mandatory site visit prior to bid opening is scheduled. Prospective bidders may contact Contract Officer Selwin C. Ray at (907) 771-3035 for additional information.

The project represents a Federal and State-funded initiative for infrastructure improvement in the Manokotak community. The contract documents indicate that work is divided between base bid requirements and additive alternates, with all work shown in the drawing set included in the base bid unless specifically designated as an additive alternate. The design package was issued for construction in August 2025 as Revision #1. No specific pricing information, set-asides, incumbent contractor details, or bid due dates are provided in this portion of the contract documentation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P.O. 111405, Anchorage, AK 99511 (907)349-0100

ALASKA ENERGY AUTHORITY

MANOKOTAK POWER PLANT

UPGRADE PROJECT

REVISION #1 ISSUED FOR

CONSTRUCTION AUGUST 2025

THIS DRAWING SET SHOWS WORK THAT IS UNDER THE

BASE BID AND ADDITIVE ALTERNATES. ALL WORK SHOWN

IS INCLUDED IN THE BASE BID UNLESS SPECIFICALLY

INDICATED AS ADDITIVE ALTERNATE.

PURCHASE ORDER NUMBER: PO010800

CONTROLLED POWER, INC. JOB No. 9332SG

MANOKOTAK POWER SYSTEM UPGRADE

350 KW

GEN LOCKOUT

OFF RUN

ALARM RESET

SERVICE

HOURS RESET

MANUFACTURED BY:

BOTHELL, WA. 98012

SERIAL NUMBER: 9332SG

CONTROLLED POWER, INC.

17909 BOTHELL EVERETT HWY. S.E.

(425)-485-1778

350 KW

GEN LOCKOUT

OFF RUN

ALARM RESET

SERVICE

HOURS RESET

350 KW

GEN LOCKOUT

OFF RUN

ALARM RESET

SERVICE

HOURS RESET

RADIATOR FAN 1

RADIATOR FAN 1

OFFVFD BYPASS

RADIATOR FAN 2

OFFVFD BYPASS

RADIATOR FAN 2CHARGE AIR COOLER 1

CHARGE AIR COOLER 1

OFFVFD BYPASS

CHARGE AIR COOLER 2

OFFVFD BYPASS

CHARGE AIR COOLER 2

RADIATOR FAN 2

OFFVFD BYPASS

CHARGE AIR COOLER 3

BYPASSVFD OFF

GEN LOCKOUT

OFF RUN

RADIATOR FAN 1

GENERATOR 1

MASTER CONTROL STATION SERVICE

RADIATOR FAN 1

OFFVFD BYPASS

BUS TOTALIZING

RADIATOR FAN 2

MANUFACTURED BY:

BOTHELL, WA. 98012

SERIAL NUMBER: 9332SG

CONTROLLED POWER, INC.

17909 BOTHELL EVERETT HWY. S.E.

(425)-485-1778

FEEDER

GENERATOR 1

GENERATOR 2

VFD MAIN

STATION SERVICE

GENERATOR 2

RADIATOR FAN 2

OFFVFD BYPASS

LAMP

TEST

ALARM

RESET

FEEDER & VFD

350 KW

GENERATOR 3

GENERATOR 3

GENERATOR

LOCKOUT FOR SERVICE

OFF RUN

ALARM RESET

SERVICE

HOURS RESET

CUTOUT DETAIL

CHARGE AIR COOLER 1

CHARGE AIR COOLER 2

CHARGE AIR COOLER 3

VFD

CHARGE AIR COOLER 1

OFFVFD BYPASS

CHARGE AIR COOLER 2

OFFVFD BYPASS

CHARGE AIR COOLER 3

OFFVFD BYPASS

Cover
Electrical
Switchgear 9332SG Shop As Builts