26-8624_Immokalee_Sports_Complex_Section_C_-_Lighting_Design.pdf

PDF 2 MB Posted

Attached to
Immokalee Sports Complex Phase 1A
Solicitation number
26-8624
Issued by
Collier County, Florida

About this file

Lighting Design Document Summary

This is a lighting design specification document prepared by Musco Sports Lighting, LLC for the Immokalee Sports Complex Soccer Relight project in Immokalee, Florida, as part of the Collier County Immokalee Sports Complex Phase 1A construction project (Bid No. 26-8624). The design provides engineered specifications for a comprehensive LED lighting system across three soccer fields with a total of 60 fixtures distributed across 15 structures. The system includes 56 TLC-LED-1200 fixtures (1170W each, 150,000 lumens) and 4 TLC-LED-1500 fixtures (1410W each, 181,000 lumens) configured across three electrical circuits (A, B, and C) with a combined total load of 71.16 kilowatts. Structure heights vary between 70 and 80 feet, with all fixtures attached at their respective structure heights. The three soccer field grids are sized at 360' x 200' (Soccer 1), 330' x 225' (Soccer 2), and 330' x 225' (Soccer 3), each achieving guaranteed average maintained horizontal illumination of 30 footcandles with maximum-to-minimum ratios not exceeding 1.72. All fixtures utilize 5700K color temperature LED sources with 75 CRI and demonstrate L70 and L80 ratings exceeding 120,000 hours, with illumination performance guaranteed per Musco's warranty documentation.

The electrical system accommodates single-phase voltages ranging from 208V to 480V, with individual fixture amperage draws specified for each voltage configuration. Spill and glare analysis at property lines demonstrates controlled light spillage with a maintained average of 3.15 horizontal footcandles, while residential areas maintain an average of 0.42 horizontal footcandles. The design assumes 3 percent nominal voltage at the line side of drivers and accounts for structures positioned within 3 feet of design locations. Installation requires compliance with voltage specifications, proper pole positioning, and adherence to Musco's control system requirements. The illumination calculations utilize grid spacing of 30' x 30' for primary field analysis and 10' x 10' spacing for spectator area evaluation, with performance verified through photometric modeling across all three soccer field areas and perimeter zones.

View the file

Other files

File Type Posted
26-8624_Bid_Schedule_R2.xlsx XLSX spreadsheet
M-02_Revised_Specification_Page_C-108.pdf PDF
M-02_Revised_Specification_Page_C-109.pdf PDF
M-02_Revised_Specification_Page_C100.pdf PDF
26-8624_-_Solicitation..pdf PDF
26-8624_-_Solicitation..pdf PDF
26-8624_ATA_-_Executed.pdf PDF
26-8624_ATA_-_Executed.pdf PDF
26-8624_-_Exhibit_M_-_01_ISC-Phase1ASubmittal(Final)_Keysheets_SS.pdf PDF
26-8624_-_Exhibit_N_-_EHS_Contractor_Requirements_Master_2021_rev.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
26-8624_-_Exhibit_J_-_ISC_Phase1A(Final)_SS.pdf PDF
26-8624_-_Exhibit_M_-_02_ISC-Phase1ASubmittal(Final)_Civil-SS.pdf PDF
26-8624_-_Exhibit_M_-_03_ISC-Phase1ASubmittal(Final)_Landscape-SS.pdf PDF
Construction_Bid_Instructions_Version_1.pdf PDF
26-8624_-_Exhibit_M_-_02_ISC-Phase1ASubmittal(Final)_Civil-SS.pdf PDF
26-8624_-_Exhibit_M_-_03_ISC-Phase1ASubmittal(Final)_Landscape-SS.pdf PDF
Construction_Services_Agreement_2025_Template_ver_3_with_Exhibits.pdf PDF
26-8624_-_Exhibit_J_-_ISC_Phase1A(Final)_SS.pdf PDF
26-8624_-_Exhibit_M_-_01_ISC-Phase1ASubmittal(Final)_Keysheets_SS.pdf PDF
Construction_Services_Agreement_2025_Template_ver_3_with_Exhibits.pdf PDF
26-8624_-_Bid_Schedule.xlsx XLSX spreadsheet
26-8624_-_Exhibit_L_-_Scope_of_Work.pdf PDF
26-8624_-_Exhibit_L_-_Scope_of_Work.pdf PDF
26-8624_-_Exhibit_N_-_EHS_Contractor_Requirements_Master_2021_rev.pdf PDF
Construction_Bid_Instructions_Version_1.pdf PDF
PO_Terms_and_Conditions_Rev.3.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C. LIGHTING DESIGN

Immokalee Sports Complex Soccer Relight, 141394

PROJECT SUMMARY

Not to be reproduced in whole or part without the wri en consent of Musco Sports Ligh ng, LLC.

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

Immokalee Sports Complex Retrofit Immokalee,FL

LIGHTING SYSTEM

Structure/Fixture Summary Structure ID Structure Height Fixt. Attachment Ht. Fixture Qty Fixture Type Load Circuit

S1 70' 70' 1 TLC-LED-1500 1.41 kW A 70' 2 TLC-LED-1200 2.34 kW A

S2 70' 70' 3 TLC-LED-1200 3.51 kW A S3 70' 70' 1 TLC-LED-1500 1.41 kW A

70' 2 TLC-LED-1200 2.34 kW A S4 80' 80' 1 TLC-LED-1500 1.41 kW A

80' 3 TLC-LED-1200 3.51 kW A 80' 3 TLC-LED-1200 3.51 kW B

S5 80' 80' 3 TLC-LED-1200 3.51 kW A 80' 4 TLC-LED-1200 4.68 kW B

S6 80' 80' 1 TLC-LED-1500 1.41 kW A 80' 3 TLC-LED-1200 3.51 kW A 80' 3 TLC-LED-1200 3.51 kW B

S7 80' 80' 3 TLC-LED-1200 3.51 kW B S8 80' 80' 4 TLC-LED-1200 4.68 kW B S9 80' 80' 3 TLC-LED-1200 3.51 kW B

S10 70' 70' 3 TLC-LED-1200 3.51 kW C S11 70' 70' 4 TLC-LED-1200 4.68 kW C

S12-S13 70' 70' 3 TLC-LED-1200 3.51 kW C S14 70' 70' 4 TLC-LED-1200 4.68 kW C S15 70' 70' 3 TLC-LED-1200 3.51 kW C 15 60 71.16 kW

Circuit Summary Circuit Description Load Fixture Qty

A Soccer 3 24.36 kW 20 B Soccer 2 23.40 kW 20 C Soccer 1 23.40 kW 20

Fixture Type Summary Type Circuit Source Wattage Lumens L90 L80 L70 Quantity

TLC-LED-1200 A LED 5700K - 75 CRI 1170W 150,000 >120,000 >120,000 >120,000 16

TLC-LED-1200 B LED 5700K - 75 CRI 1170W 150,000 >120,000 >120,000 >120,000 20

TLC-LED-1200 C LED 5700K - 75 CRI 1170W 150,000 >120,000 >120,000 >120,000 20

TLC-LED-1500 A LED 5700K - 75 CRI 1410W 181,000 >120,000 >120,000 >120,000 4

Single Fixture Amperage Draw Chart Driver Speci ca ons

(.90 min power factor) Line Amperage Per Fixture

(max draw)

Single Phase Voltage 208 (60)

(60)

(60)

(60)

(60)

(60)

(60)

TLC-LED-1500 8.4 7.9 7.3 6.3 5.0 4.6 3.6

TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0

Light Level Summary

Calculation Grid Summary Grid Name Calculation Metric Illumination Ave Circuits Fixture QtyAve Min Max Max/Min Ave/Min

Soccer 1 Horizontal Illuminance 31.80 24 39 1.61 1.31 C 20 Soccer 1 Spectator Area Horizontal 20.51 0 41 260.65 129.08 C 20

Soccer 2 Horizontal Illuminance 30.60 22 39 1.72 1.36 B 20 Soccer 2 Spectator Area Horizontal 20.88 0 41 110.36 56.74 B 20

Soccer 3 Horizontal Illuminance 32.00 25 41 1.65 1.27 A 20 Soccer 3 Spectator Area Horizontal 21.73 0 43 122.24 62.27 A 20

Spill/Glare - Property Line Horizontal 3.15 0 22 48502.27 6796.54 A,B,C,D 60 Spill/Glare - Property Line Max Candela (by Fixture) 93991.70 1284 405577 315.77 73.18 A,B,C,D 60 Spill/Glare - Property Line Max Vertical Illuminance Metric 5.50 0 34 4291.07 691.24 A,B,C,D 60

Spill/Glare - Residential Horizontal 0.42 0 2 2658.27 529.19 A,B,C,D 60 Spill/Glare - Residential Max Candela (by Fixture) 42118.49 10306 95806 9.30 4.09 A,B,C,D 60 Spill/Glare - Residential Max Vertical Illuminance Metric 0.99 0 5 201.96 44.47 A,B,C,D 60

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S10 S11 S12

S13S14S15

8'

137'

8'

2'

9'

133'

2'

4'

2'

131'

2'

138'

NO PARKING

EXISTING RETENTION AREA 6:

0.002 ACRE-FT

W

{\C

256;SAN

{\C

256;SAN

SCALE IN FEET 1 : 50

0' 50' 100'

Equipment List For Areas Shown Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

S10

S12-S13 S15

70' - 70' TLC-LED-1200 3 3 0

2 S11

S14 70' - 70' TLC-LED-1200 4 4 0

6 Totals 20 20 0 Above Field Level is height of fixtures above area shown

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Soccer 1 Size: 360' x 200'

Spacing: 30.0' x 30.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Guaranteed Average: 30

Scan Average: 31.80 Maximum: 39 Minimum: 24

Avg/Min: 1.31 Guaranteed Max/Min: 2.5

Max/Min: 1.61 UG (adjacent pts): 1.48

CU: 0.79

No. of Points: 84

FIXTURE INFORMATION

Applied Circuits: C No. of Fixtures: 20

Total Load: 23.40 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S10 S11 S12

S13S14S15

8'

137'

8'

2'

9'

133'

2'

4'

2'

131'

2'

138'

NO PARKING

EXISTING RETENTION AREA 2:

0.076 ACRE-FT

EXISTING RETENTION AREA 6:

0.002 ACRE-FT

W

{\C

256;SAN

{\C

256;SAN

SCALE IN FEET 1 : 60

0' 60' 120'

Equipment List For Areas Shown Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

S10

S12-S13 S15

70' - 70' TLC-LED-1200 3 3 0

2 S11

S14 70' - 70' TLC-LED-1200 4 4 0

6 Totals 20 20 0 Above Field Level is height of fixtures above area shown

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Soccer 1 Spectator Area Size: 360' x 200'

Spacing: 10.0' x 10.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Scan Average: 20.51

Maximum: 41 Minimum: 0

Avg/Min: 129.08 Max/Min: 260.65

UG (adjacent pts): 3.58

CU: 0.94

No. of Points: 1400

FIXTURE INFORMATION

Applied Circuits: C No. of Fixtures: 20

Total Load: 23.40 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S9S8

S7

5'

108'

6'

11'

4'

106'

3'

133'

3'

14'

5'

130'

S4S6 S5

W

{\C

256;SAN

SCALE IN FEET 1 : 40

0' 40' 80'

Equipment List For Areas Shown Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 S4

S6 80' - 80' TLC-LED-1200 3/3* 3 3

80' TLC-LED-1500 1 0 1

1 S5 80' - 80' TLC-LED-1200 3/4* 4 3

2 S7

S9 80' - 80' TLC-LED-1200 3 3 0

1 S8 80' - 80' TLC-LED-1200 4 4 0

6 Totals 31 20 11

*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Soccer 2 Size: 330' x 225'

Spacing: 30.0' x 30.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Guaranteed Average: 30

Scan Average: 30.60 Maximum: 39 Minimum: 22

Avg/Min: 1.36 Guaranteed Max/Min: 2.5

Max/Min: 1.72 UG (adjacent pts): 1.47

CU: 0.79

No. of Points: 88

FIXTURE INFORMATION

Applied Circuits: B No. of Fixtures: 20

Total Load: 23.40 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S9S8S7

5'

108'

6'

11'

4'

106'

3'

133'

3'

14'

5'

130'

S4S6 S5

W

{\C

256;SAN

SCALE IN FEET 1 : 60

0' 60' 120'

Equipment List For Areas Shown Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 S4

S6 80' - 80' TLC-LED-1200 3/3* 3 3

80' TLC-LED-1500 1 0 1

1 S5 80' - 80' TLC-LED-1200 3/4* 4 3

2 S7

S9 80' - 80' TLC-LED-1200 3 3 0

1 S8 80' - 80' TLC-LED-1200 4 4 0

6 Totals 31 20 11

*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Soccer 2 Spectator Area Size: 330' x 225'

Spacing: 10.0' x 10.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Scan Average: 20.88

Maximum: 41 Minimum: 0

Avg/Min: 56.74 Max/Min: 110.36

UG (adjacent pts): 2.15

CU: 0.96

No. of Points: 1400

FIXTURE INFORMATION

Applied Circuits: B No. of Fixtures: 20

Total Load: 23.40 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S4

S3

S6

S1 S2

S5

4'

107'

5'

133'

4'

14'

1'

5'

0'

139'

2'

128'

SCALE IN FEET 1 : 40

0' 40' 80'

Equipment List For Areas Shown Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 S1

S3 70' - 70' TLC-LED-1200 2 2 0

70' TLC-LED-1500 1 1 0

1 S2 70' - 70' TLC-LED-1200 3 3 0

2 S4

S6 80' - 80' TLC-LED-1200 3/3* 3 3

80' TLC-LED-1500 1 1 0

1 S5 80' - 80' TLC-LED-1200 3/4* 3 4

6 Totals 30 20 10

*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Soccer 3 Size: 330' x 225'

Spacing: 30.0' x 30.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Guaranteed Average: 30

Scan Average: 32.00 Maximum: 41 Minimum: 25

Avg/Min: 1.27 Guaranteed Max/Min: 2.5

Max/Min: 1.65 UG (adjacent pts): 1.52

CU: 0.80

No. of Points: 88

FIXTURE INFORMATION

Applied Circuits: A No. of Fixtures: 20

Total Load: 24.36 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S4

S3

S6

S1 S2

S5

4'

107'

5'

133'

4'

14'

1'

5'

0'

139'

2'

128'

SCALE IN FEET 1 : 60

0' 60' 120'

Equipment List For Areas Shown Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THIS

GRID

OTHER

GRIDS

2 S1

S3 70' - 70' TLC-LED-1200 2 2 0

70' TLC-LED-1500 1 1 0

1 S2 70' - 70' TLC-LED-1200 3 3 0

2 S4

S6 80' - 80' TLC-LED-1200 3/3* 3 3

80' TLC-LED-1500 1 1 0

1 S5 80' - 80' TLC-LED-1200 3/4* 3 4

6 Totals 30 20 10

*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Soccer 3 Spectator Area Size: 330' x 225'

Spacing: 10.0' x 10.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Scan Average: 21.73

Maximum: 43 Minimum: 0

Avg/Min: 62.27 Max/Min: 122.24

UG (adjacent pts): 2.69

CU: 0.97

No. of Points: 1400

FIXTURE INFORMATION

Applied Circuits: A No. of Fixtures: 20

Total Load: 24.36 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S3S1 S2

S4S6 S5

S9S8S7

S10 S11 S12

S13S14S15

15.12

1.09 0.48

0.41 0.30

0.13

0.05 0.030.02

0.01

0.01

0.01

0.01

0.01

0.01

0.02

0.02

0.02

0.01

0.01

0.01

0.00

0.00

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

0.00

0.00

0.01

0.07

0.32

1.30

7.83

22.49

15.28

10.72

12.10

14.91

11.66

5.12

2.31

2.52

6.46

9.88

7.74

6.50

6.62

8.68

10.88

5.95

2.43

2.79

5.44

8.23

9.51

8.67

9.43

9.57

7.50

3.43

1.42

0.290.510.831.552.012.081.591.622.092.452.081.391.070.56

1.59

3.43

5.74

5.75

4.61

4.59

5.08

3.99

2.28

1.31

1.06

1.33

2.08

2.44

1.20

0.54

0.50

0.71

1.15

3.08

13.04

8.48

4.62

0.81

0.78

12.84

NO PARKING

EXISTING RETENTION AREA 3:

0.079± ACRE-FT

EXISTING RETENTION AREA 2:

0.076 ACRE-FT

EXISTING RETENTION AREA 6:

0.002 ACRE-FT

{\C

256;SA

N

{\C

256;SA

N

SCALE IN FEET 1 : 150

0' 150' 300'

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Spill/Glare - Property Line Spacing: 30.0' x 10.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Scan Average: 3.15

Maximum: 22 Minimum: 0

No. of Points: 117

FIXTURE INFORMATION

Applied Circuits: A,B,C,D No. of Fixtures: 60

Total Load: 71.16 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S3S1 S2

S4S6 S5

S9S8S7

S10 S11 S12

S13S14S15

29.76

6.39 3.29

3.16 2.52

1.24

0.58 0.350.26

0.17

0.12

0.12

0.13

0.16

0.21

0.22

0.22

0.22

0.19

0.14

0.09

0.06

0.03

0.01 0.01 0.01 0.02 0.04 0.06 0.08 0.09 0.10 0.09 0.09 0.08 0.06 0.05 0.05 0.04 0.03 0.03 0.02

0.02

0.03

0.05

0.18

0.66

2.14

11.48

34.15

23.99

13.46

22.23

27.61

19.31

7.78

3.66

4.25

11.01

17.98

14.48

10.15

10.86

15.95

19.06

9.89

4.07

4.62

9.41

15.42

18.36

14.44

14.47

15.92

11.55

4.71

2.04

0.620.971.241.672.042.331.992.172.472.692.562.121.761.11

2.17

4.66

8.80

8.54

7.92

9.81

10.38

7.31

3.81

2.11

1.75

2.21

3.56

4.43

2.18

2.24

2.97

4.25

6.11

9.05

19.09

15.39

6.91

4.88

5.24

16.13

NO PARKING

EXISTING RETENTION AREA 3:

0.079± ACRE-FT

EXISTING RETENTION AREA 2:

0.076 ACRE-FT

EXISTING RETENTION AREA 6:

0.002 ACRE-FT

{\C

256;SA

N

{\C

256;SA

N

SCALE IN FEET 1 : 150

0' 150' 300'

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Spill/Glare - Property Line Spacing: 30.0' x 10.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED MAX VERTICAL FOOTCANDLES

Entire Grid Scan Average: 5.50

Maximum: 34 Minimum: 0

No. of Points: 117

FIXTURE INFORMATION

Applied Circuits: A,B,C,D No. of Fixtures: 60

Total Load: 71.16 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S3S1 S2

S4S6 S5

S9S8S7

S10 S11 S12

S13S14S15

243817

201065

106289

119642 110308

47574

34804

2836525490

19573

14637

11081

13310

19124

26352

28910

29215

29840

26739

19415

13660

2278 1284 1410 4221 7912 13698 20691 25039 27574 28477 27833 26198 23390 20787 17999 15069 11972 9332 7688

10320

12442

15451

18763

39562

94658

338214

294089

188636

372157

405577

215673

58628

23051

33702

138814

284480

232300

138258

174211

276770

297619

120772

34404

43547

112993

231978

325014

236500

272631

227573

150633

105207

60198

3320947965455224158452715543475356574112760658661112263413080311310076625

102644

136732

165733

184909

168721

160543

163796

91759

34035

20696

27960

36660

47777

75777

75916

80270

99258

125931

140804

131751

116091

69177

104929

161802

185944

210989

NO PARKING

EXISTING RETENTION AREA 3:

0.079± ACRE-FT

EXISTING RETENTION AREA 2:

0.076 ACRE-FT

EXISTING RETENTION AREA 6:

0.002 ACRE-FT

{\C

256;SA

N

{\C

256;SA

N

SCALE IN FEET 1 : 150

0' 150' 300'

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Spill/Glare - Property Line Spacing: 30.0' x 10.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED MAX CANDELA (PER FIXTURE)

Entire Grid Scan Average: 93991.70

Maximum: 405577 Minimum: 1284

No. of Points: 117

FIXTURE INFORMATION

Applied Circuits: A,B,C,D No. of Fixtures: 60

Total Load: 71.16 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S3S1 S2

S4S6 S5

S9S8S7

S10 S11 S12

S13S14S15

0.00

0.00

0.02

0.05

0.13

0.38

1.20

2.12

1.55

1.03

1.38

1.57

1.04

0.62

0.52

0.59

0.91

1.21

1.10

0.94

1.20

1.57

1.30

0.79

0.55

0.73

0.99

1.40

1.45

1.43

1.37

1.11

0.76

0.47

0.18

0.04

0.010.010.030.040.070.090.100.110.140.170.190.160.130.120.090.050.040.020.010.010.000.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.00

0.01

0.01

0.01

0.01

NO PARKING

EXISTING RETENTION AREA 3:

0.079± ACRE-FT

EXISTING RETENTION AREA 2:

0.076 ACRE-FT

EXISTING RETENTION AREA 6:

0.002 ACRE-FT

{\C

256;SA

N

{\C

256;SA

N

SCALE IN FEET 1 : 150

0' 150' 300'

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Spill/Glare - Residential Spacing: 30.0' x 10.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES

Entire Grid Scan Average: 0.42

Maximum: 2 Minimum: 0

No. of Points: 79

FIXTURE INFORMATION

Applied Circuits: A,B,C,D No. of Fixtures: 60

Total Load: 71.16 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S3S1 S2

S4S6 S5

S9S8S7

S10 S11 S12

S13S14S15

0.02

0.03

0.07

0.15

0.34

0.84

2.52

4.51

3.16

2.69

3.54

3.72

2.28

1.36

1.17

1.34

2.07

2.82

2.62

1.93

2.76

3.59

2.89

1.76

1.23

1.64

2.28

3.29

3.31

2.97

2.63

2.15

1.46

0.91

0.43

0.15

0.060.070.120.170.230.270.270.300.400.520.560.580.580.550.430.270.190.130.090.060.060.06

0.06

0.07

0.07

0.08

0.08

0.08

0.08

0.07

0.07

0.06

0.05

0.05

0.06

0.07

0.09

0.11

0.13

0.15

0.15

0.15

0.15

NO PARKING

EXISTING RETENTION AREA 3:

0.079± ACRE-FT

EXISTING RETENTION AREA 2:

0.076 ACRE-FT

EXISTING RETENTION AREA 6:

0.002 ACRE-FT

{\C

256;SA

N

{\C

256;SA

N

SCALE IN FEET 1 : 150

0' 150' 300'

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Spill/Glare - Residential Spacing: 30.0' x 10.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED MAX VERTICAL FOOTCANDLES

Entire Grid Scan Average: 0.99

Maximum: 5 Minimum: 0

No. of Points: 79

FIXTURE INFORMATION

Applied Circuits: A,B,C,D No. of Fixtures: 60

Total Load: 71.16 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

S3S1 S2

S4S6 S5

S9S8S7

S10 S11 S12

S13S14S15

10306

11852

14592

17252

19537

23594

40989

83532

60020

74079

88836

78284

35923

24649

20084

17494

39174

62787

61102

30659

74880

95806

64332

28105

30387

34585

40772

70854

76543

61665

59157

61043

49747

35820

33496

31406

31502 3122229933269982504723079200571716017511261262677441348561105945849203312812283618560255243038434910

39689

42897

47029

48987

50518

50284

49409

44978

40746

35279

29430

20695

13567

21576

32294

43500

54202

63512

70853

73979

74433

71140

NO PARKING

EXISTING RETENTION AREA 3:

0.079± ACRE-FT

EXISTING RETENTION AREA 2:

0.076 ACRE-FT

EXISTING RETENTION AREA 6:

0.002 ACRE-FT

{\C

256;SA

N

{\C

256;SA

N

SCALE IN FEET 1 : 150

0' 150' 300'

Immokalee Sports Complex Retrofit Immokalee,FL Grid Summary

Name: Spill/Glare - Residential Spacing: 30.0' x 10.0' Height: 3.0' above grade

Illumination Summary

MAINTAINED MAX CANDELA (PER FIXTURE)

Entire Grid Scan Average: 42118.49

Maximum: 95806 Minimum: 10306

No. of Points: 79

FIXTURE INFORMATION

Applied Circuits: A,B,C,D No. of Fixtures: 60

Total Load: 71.16 kW

Pole location(s) dimensions are relative to 0,0 reference point(s)

Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3%

EQUIPMENT LAYOUT

©1981, 2025 Musco Sports Ligh ng, LLC.ENGINEERED DESIGN By: Joe Nicholson • File #141394F • 09-Dec-25

Immokalee Sports Complex Retrofit Immokalee,FL

Soccer 3 330' x 225'

S3

S1

S2

S4

S6

S5

6Soccer 2

330' x 225'

S9

S8

S7

(0.28', -307.83', 0.00')

Soccer 1 360' x 200'

S10

52 53

S11

S12

S13

S14

S15

(-0.88', -600.23', 0.00')

NO PARKING

EXISTING RETENTION AREA 3:

0.079± ACRE-FT

EXISTING RETENTION AREA 2:

0.076 ACRE-FT

EXISTING RETENTION AREA 6:

0.002 ACRE-FT

{\C

256;SA

N

{\C

256;SA

N

(0.00', 0.00', 0.00')

SCALE IN FEET 1 : 150

0' 150' 300'

Pole location(s) dimensions are relative to 0,0 reference point(s)

Equipment Layout

INCLUDES:

· Soccer 1

· Soccer 2

· Soccer 3 Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing.

Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

Equipment List For Areas Shown Structure Fixtures

QTY STRUCTURE

ID SIZE GLOBAL

ELEVATION ABOVE GLOBAL LEVEL FIXTURE TYPE QTY/POLE

2 S1 S3 70' - 70'

70'

TLC-LED-1200

TLC-LED-1500

S2 S10

S12-S13 S15

70' - 70' TLC-LED-1200 3

2 S4 S6 80' - 80'

80'

TLC-LED-1200

TLC-LED-1500

3/3*

1 S5 80' - 80' TLC-LED-1200 3/4*

2 S7

S9 80' - 80' TLC-LED-1200 3

1 S8 80' - 80' TLC-LED-1200 4

2 S11

S14 70' - 70' TLC-LED-1200 4

15 Totals 60

Single Fixture Amperage Draw Chart Driver Speci ca ons

(.90 min power factor) Line Amperage Per Fixture

(max draw)

Single Phase Voltage 208 (60)

(60)

(60)

(60)

(60)

(60)

(60)

TLC-LED-1500 8.4 7.9 7.3 6.3 5.0 4.6 3.6

TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0

*This structure utilizes a back-to-back mounting configuration Above Global Level is height of fixtures above design (0,0,0)

File details come from the government source that posted it. Updated .