26-10_CAR833409A Plans 09-29-2026.pdf

PDF 6 MB Posted

Attached to
26-10 Car833409A (Carroll)
Solicitation number
009-RFB-WRBWL-CY26-10
Issued by
Carroll County, Iowa

About this file

These are construction plans for a nutrient reduction wetland project in Carroll County, Iowa, prepared by Bolton & Menk, Inc. on behalf of the Iowa Department of Agriculture and Land Stewardship (IDALS). The project, identified as IDALS No. CAR833409A and located at the Thrills Hills Wetland site, involves construction of a 3.5-acre wetland pool designed to treat water from an existing ditch system using a solar-powered pump system. The scope of work includes excavation of approximately 13,310 cubic yards of general material, placement of 4,790 cubic yards of earthfill for embankments and dam construction, installation of 250 linear feet of 18-inch reinforced concrete pipe (RCP) for the pumped inlet and 130 linear feet of 36-inch RCP for the outlet, installation of 954 linear feet of 8-inch dual-wall HDPE pipe, construction of one modified SW-513 concrete outlet structure (78 inches by 78 inches) and one SW-401 pump basin structure, placement of a solar-powered 3-phase, 3-horsepower pump system providing 340 gallons per minute at 11.25 feet of total dynamic head, installation of six anti-seep collars, placement of 29.3 tons of Class E riprap, and seeding of 2.4 acres (1.5 acres structure seeding and 0.9 acres buffer seeding). The project design includes a normal water level elevation of 1217.00 feet with a maximum 100-year pool depth of 2.0 feet and average depth of 1.2 feet, with the auxiliary spillway set at elevation 1218.50 feet. A pre-construction meeting must occur within 7 days of contract award, with construction scheduled for completion by September 1, 2027, and all seeding work to be completed by December 15, 2027. The bidders' meeting is scheduled for October 6, 2026, at 11:00 AM at Carroll Public Library, with virtual attendance available, and bids are due October 27, 2026, at 3:00 PM.

The estimated construction cost range is $175,000 to $275,000. All bidders must be registered with the Iowa Department of Inspections, Appeals & Licensing prior to contract execution. Bid security of 10 percent of the bid price is required, and the successful bidder must furnish a Performance/Payment Bond equal to 100 percent of the contract price. Written technical questions regarding the project must be submitted to Brandon Short, P.E., of Bolton & Menk with a copy to Tracy Bruun at tracy.blocker@iowaagriculture.gov by 3:00 PM on October 14, 2026, for inclusion in a final addendum. The project plans incorporate NRCS Construction Practice Standard 656 (Constructed Wetland) with a Job Class III designation for a watershed area exceeding 300 acres, with an effective treated watershed of 671.6 acres and a pumped watershed area of 2,105.6 acres. The design incorporates a pump peak flow of 0.78 cubic feet per second capturing 32 percent of the watershed flow, and includes provisions for compliance with all applicable federal, state, and local laws and ordinances, NRCS standards, Iowa Statewide Urban Standard Specifications for Public Improvements, and Iowa Department of Transportation Standard Specifications for Highway and Bridge Construction.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ARTHUR

N. NEU

MUNICIPAL

AIRPORT

280TH ST

230TH ST

250TH ST

RO

BI

N A

V E

O

LY

M

PI

C A

V E

250TH ST

N O

BL

E

A V

E

Q

UA

IL

A

V E

200TH ST

235TH ST

240TH ST

225TH ST

N O

BL

E

A V

E

M

ES

Q

UI

TE

A

V E

232ND ST

O

RA

N G

E A

V E

PH

O

EN

IX

A V

E

PE

EB

LE

A

V E

N O

BL

E

A V

E

M A

HO

G

A N

Y A

V E

272ND ST

Q

UA

IL

A

V E

230TH ST

240TH ST

KI

TT

YH

A

W K

A V

E

265TH ST

260TH ST

IV

Y

A V

E

UN

IO

N A

V E

O

LY

M

PI

C A

V E

RO

BI

N A

V E

180TH ST

PH

O

EN

IX

A V

E215TH ST

IV

Y

A V

E

210TH ST

280TH ST

TIM

BE

R A

V E

V

EL

V

ET

A V

E

TIM

BE

R A

V E

O

LY

M

PI

C A

V E

Q

UA

IL

A

V E

Q

UA

RT

Z

A V

E

250TH ST

RO

BI

N A

V

E 250TH ST

JA

D

E A

V E

245TH ST

JA

D E

A V

E

270TH ST 270TH ST

TIM

BE

R A

V E

M A

HO

G

A N

Y A

V E

Q

UA

IL

A

V E

190TH ST

M A

HO

G

A N

Y A

V E

210TH ST

200TH ST

JA

D

E A

V E

PH

O

EN

IX

A V

E

280TH ST280TH ST

280TH ST

KI

TT

YH

A

W K

A V

E

220TH ST

UN

IO

N A

V E

255TH ST

265TH ST

SY

C

A M

O

RE

A V

E 270TH ST

220TH ST

M A

HO

G

A N

Y A

V E

N O

BL

E

A V

E

230TH ST

240TH ST

PE

EB

LE

A

V E

260TH ST

265TH ST

260TH ST

270TH ST

220TH ST220TH ST

235TH ST

IV

Y A

V E

KI

TT

YH

A

W K

A V

E

250TH ST

255TH ST

SY

C

A M

O

RE

A V

E

TW

ILI

G

HT

A V

E

SY

C

A M

O

RE

A V

E

190TH ST

UN

IO

N A

V E

210TH ST

PH

O

EN

IX

A V

E

180TH ST

190TH ST

RO

BI

N A

V E

G

RA

N

ITE

A V

E

IRIS RD

JA

D

E A

V E

KI

TT

YH

A

W K

A V

E

180TH ST

180TH ST

KI

TT

YH

A

W K

A V

E

210TH ST

210TH ST

220TH ST

215TH

ST

O

LY

M

PI

C A

V E

235TH

ST

235TH

ST

A V

E

RA

N C

H

205TH

ST

HA

W

TH

O

RN

E

A V

E

HA

W

TH

O

RN

E A

V E

HA

W

TH

O

RN

E

A V

E

245TH ST

Q

UA

RT

Z

A

VE

LA

RE

D O

A V

E

N O

BL

E

A V

E

CARROLL

HALBUR

GLIDDEN

WILLEY

MAPLE

RIVER

JCT.

ROSELLE

SWAN

LAKE

STATE

PARK

G L I D D E N

G R A N T

R O S E L L E

R I C H L A N D

M A P L E

R I V E R

P L E A S A N T

V A L L E Y

7 8 9

161718

19 20 21

32 33

7 8 9 10 11 12

131415161718

20 21 22 23 24

2526272829

31 32 33

7 8 9 10 11 12

131415161718

19 20 21 22

2627282930

31 32 33 34 35 36

123456

7 8 9 10 11 12

151617

19 20 21 22 23 24

252627282930

31 32 33 34 35 36

123456

7 8 9 10 11 12

131415161718

19 20 21 22 23 24

252627282930

31 32 33 34 35 36

7 8 9

161718

19 20 21

282930

31 32 33

POP.

10103

POP.

POP.

TIM

BE

R A

V E

30 30

M iddle

River

Racc oon

SWAN

LAKE

STATE

PARKN20

E35

E35

E45N38

E45

E53

N38

N18 E53

E53

N14

N20

E37

N38

N44

E46

E46

N14

N33

N44

E53

N41

‒‒81

‒‒112 ‒‒

SWAN LAKE STATE PARK

CARROLL COUNTY

25 30 29

323136

6 5

CARROLL ARMORY

CARROLL, CARROLL COUNTY

12-14-2001

PROJECT DATUM: STATE PLANE

HORIZONTAL: IOWA NORTH

VERTICAL: NAVD 1988

MY LICENSE RENEWAL DATE IS

PAGES OR SHEETS COVERED BY THIS SEAL:

LICENSE NUMBER: DATE:

I OWA

LI

CE

NS

ED

PROFESS IONAL ENG

INEER

I HEREBY CERTIFY THAT THIS ENGINEERING DOCUMENT WAS

PREPARED BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION

AND THAT I AM A DULY LICENSED PROFESSIONAL ENGINEER

UNDER THE LAWS OF THE STATE OF IOWA.

29449

12/31/2026

ALL SHEETS

BRANDON C.

SHORT

29449

BRANDON C. SHORT, PE

CARROLL COUNTY, IA

CONSTRUCTION PLANS FOR

IDALS NO. CAR833409A

NUTRIENT REDUCTION WETLAND

CARROLL COUNTY, IOWA

SEPTEMBER 2026

THE SPECIFICATIONS AS PREPARED BY IOWA DEPARTMENT OF AGRICULTURE

AND LAND STEWARDSHIP AND BOLTON & MENK, INC. SHALL BE CONSIDERED

AS PART OF THIS DOCUMENT. NATURAL RESOURCES CONSERVATION SERVICE

CONSTRUCTION SPECIFICATIONS SHALL APPLY.

THE CURRENT EDITION OF THE "IOWA STATEWIDE URBAN STANDARD

SPECIFICATIONS FOR PUBLIC IMPROVEMENTS" SHALL GOVERN.

IOWA DEPARTMENT OF TRANSPORTATION "STANDARD SPECIFICATIONS FOR

HIGHWAY AND BRIDGE CONSTRUCTION" AND ALL CURRENT GENERAL

SUPPLEMENTAL SPECIFICATIONS AND MATERIALS INSTRUCTIONAL

MEMORANDUM SHALL GOVERN AS REFERENCED.

ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS AND ORDINANCES WILL BE

COMPLIED WITH IN THE CONSTRUCTION OF THIS PROJECT.

GOVERNING SPECIFICATIONS

NOTES

1. IF A CULTURAL RESOURCE IS IDENTIFIED DURING

CONSTRUCTION, STOP WORK IMMEDIATELY AND NOTIFY

THE LOCAL NATURAL RESOURCES CONSERVATION SERVICE

OFFICE.

2. THERE IS NO GUARANTEE THAT THE WETLAND WILL FILL OR

REMAIN FILLED WITH WATER.

R-34W

PROJECT

LOCATION

T-

N

CONSERVATION PRACTICE STANDARDS USED:

656 - CONSTRUCTED WETLAND

NRCS JOB CLASS: III

300 AC > WATERSHED AREA

TO THE BEST OF MY PROFESSIONAL KNOWLEDGE,

JUDGEMENT, AND BELIEF, THESE PLANS MEET APPLICABLE

NRCS STANDARDS AND APPLICABLE LAWS AND

REGULATIONS.

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

A0

1.

dw g 9/

/2

9:

:0

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

A.01

TITLE SHEET

MILESSCALE

0 1 2

R-33WR-35W

T-

N

T-

N T-

N

R-34W R-33WR-35W

SHEET INDEX

SHEET NUMBER SHEET TITLE

A.01 TITLE SHEET

A.02 PLAN OVERVIEW SHEET

A.03 EXISTING CONDITIONS

B.01 OUTLET STRUCTURE DETAIL

B.02 TRASH GUARD DETAIL

B.03 PUMP BASIN & SOLAR ARRAY DETAILS

B.04 CPDT INSTALLATION & ANTI-SEEP COLLAR

DETAILS

C.01 ESTIMATED QUANTITIES

D.01 GRADING OVERVIEW

D.02 EMBANKMENT PLAN & PROFILE

D.03 EMBANKMENT (CONT.) & AUXILIARY SPILLWAY

D.04 DIVERSION BERMS

K.01 SEEDING PLAN

M.01 PUMPED INLET & OUTLET PIPES

M.02 POND OUTLET PIPE

R

THE SUBSURFACE UTILITY INFORMATION IN THIS PLAN IS UTILITY QUALITY

LEVEL D. THIS UTILITY QUALITY LEVEL WAS DETERMINED ACCORDING TO

THE GUIDELINES OF CI/ASCE 38-02, ENTITLED "STANDARD GUIDELINES FOR

THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA."

THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING IOWA ONE CALL BY

PHONE AT 811, OR ON THE WEB AT

HTTP://WWW.IOWAONECALL.COM/. THIS IS REQUIRED BY LAW.

TICKET# ___________.

TICKET NUMBER MUST BE PROVIDED TO THE ENGINEER AND IDALS PRIOR

TO COMMENCEMENT OF WORK.

NRCS, IDALS, and the engineer make no representation as to the existence or nonexistence of any utility, public and/or private, buried or overhead, except as shown on the drawings. Where utilities are shown on the drawings, the location, depth and/or height are approximate. The exact location, depth and/or height must be determined by the utility company and/or the land owner prior to any construction within the project vicinity.

brandon.short Text Box 9/29/2026

OUTLET PIPE

36" RCP

OUTLET STRUCTURE

MODIFIED SW-513

78" x 78"

OUTLET PIPE INVERT

ELEV. 1207.50

10 FT EMBANKMENT

TOP ELEV. 1220

NWL = 1217.00

PUMPED INLET PIPE

18" RCP

EXCAVATE TO 1216.00

DESIGN 100-YEAR POOL HWL = 1218.80

CONSTRUCTION ACCESS

FROM PHOENIX AVE.

WEST DIVERSION BERM

TOP ELEV. 1216.50

SOLAR PUMP BASIN

PROPOSED EASEMENT BOUNDARY

30 FT AUXILIARY SPILLWAY

ELEV. 1218.50

122012 22 1222 1222

120812081212

1220 1214

1218 1218

PRESERVE EXISTING

15" CULVERT

RE-LAY POND OUTLET PIPE

8" HDPE

POND OUTLET PIPE INVERT

ELEV. 1207.50

EXISTING PRIVATE POND

SOLAR PANELS

EXCAVATE ADDITIONAL 1 FT

ELEV. 1215.00

EAST DIVERSION BERM

TOP ELEV. 1216.50

BASE FLOW RETURN PIPE

8" DUAL WALL HDPE

10" CMP TILE OUTLET

NORMAL POOL (1217.00)

100-YEAR HWL (1218.80)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 1216.00

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

A0

2.

dw g 9/

/2

9:

:1

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

A.02

PLAN OVERVIEW SHEET

R

FEETSCALE

0 50 100

HORZ.

DESIGN CRITERIA VALUE UNIT REQUIREMENT

PUMPED WATERSHED AREA 2105.6 ACRES

PUMP PEAK FLOW 0.78 CFS

PUMP PERCENT CAPTURE 32%

EFFECTIVE TREATED WATERSHED 671.6 ACRES

SURFACE WATERSHED AREA 50.4 ACRES

POOL NORMAL WATER LEVEL (NWL) ELEV 1217.00 FT

DESIGNED WETLAND POOL AREA (@ NWL) 3.5 ACRES

POOL TO WATERSHED RATIO 0.5 % Range 0.5% to 2% of watershed area

MAXIMUM POOL DEPTH 2.0 FT

AVERAGE POOL DEPTH 1.2 FT

DEEP WATER AREA (DEPTH > 3 FT) 0.0 ACRES

PERCENT DEEP WATER TO POOL AREA 0.0 % Less than 25%

POOL STORAGE VOLUME AT NWL 4.1 ACRE-FT

OVERFLOW ELEVATION 1218.50 FT

POOL STORAGE VOLUME AT OVERFLOW 9.5 ACRE-FT

PRIMARY WEIR ELEVATION 1217.00 FT Modified SUDAS SW-513 Outlet Structure PRIMARY WEIR WIDTH 24 FT 4 Sides with 6 FT Wide Openings

TOTAL EASEMENT AREA 6.8 ACRES

AREA OF BUFFER 3.3 ACRES

RATIO BUFFER AREA TO NWL POOL AREA 1.0 Less than 4

AVERAGE CAPTURE FLOW 0.23 CFS

25-YEAR STORM HWL IN POOL 1218.06 FT

25-YEAR PEAK INFLOW 112 CFS

25-YEAR PEAK OUTFLOW 87 CFS

100-YEAR STORM HWL IN POOL 1218.72 FT

100-YEAR PEAK INFLOW 171 CFS

100-YEAR PEAK OUTFLOW 109 CFS

WETLAND

POOL DEPTH ELEV INCREMENTAL

AREA

CUMULATIVE

VOLUME

CUMULATIVE

VOLUME

(FT) (FT) (FT2

) (FT3

) (AC-FT)

0.0 1215.0 356

0.5 1215.5 5,920 1,569 0.04

1.0 1216.0 136,041 37,059 0.85

1.5 1216.5 139,466 105,936 2.43

2.0 1217.0 152,192 178,851 4.11

2.5 1217.5 155,747 255,835 5.87

3.0 1218.0 159,336 334,606 7.68

3.5 1218.5 162,957 415,179 9.53

4.0 1219.0 167,469 497,786 11.43

4.5 1219.5 171,353 582,491 13.37

5.0 1220.0 176,943 669,565 15.37

122412261228

1232123412361238

361238

1222 12

12101212

12121214 12141216

1212 1212

PRESERVE EXISTING 15" CMP CULVERT

ELEV. 1219.65

2" REBAR LAND MARKER

ELEV. 1222.30

BROKEN HEAD MAG NAIL

REMOVE EXISTING POND OUTLET PIPE

(SEE NOTE)

FEMA NFHL 1% HAZARD BOUNDARY

ELEV. ≈ 1215

FEMA NFHL 0.2% HAZARD BOUNDARY

ELEV. ≈ 1216

NOTES:

1. THE ENTIRE POND OUTLET PIPE MUST

BE REMOVED AND DISPOSED OF.

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

A0

3.

dw g 9/

/2

9:

:3

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

A.03

EXISTING CONDITIONS

R

FEETSCALE

0 40 80

HORZ.

704706

CONTROL POINTS

POINT NORTHING EASTING ELEVATION DESCRIPTION

700 3473835.060 4567313.018 1231.32 1/2" REBAR LAND MARKER

704 3473795.626 4567279.458 1228.24 1/2" REBAR LAND MARKER

706 3473841.885 4566874.564 1233.89 1/2" REBAR LAND MARKER

707 3473855.733 4565991.066 1229.28 5/8" REBAR LAND MARKER

708 3471209.088 4567274.982 1278.96 1/2" REBAR LAND MARKER

712 3471228.555 4565964.019 1284.18 1/2" REBAR LAND MARKER

715 3473266.255 4566865.429 1219.65 1/2" REBAR LAND MARKER

716 3472991.157 4567300.782 1222.30 BROKEN HEAD MAG NAIL

718 3473815.518 4565990.723 1223.34 1/2" REBAR LAND MARKER

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

B0

1.

dw g 9/

/2

9:

:4

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.01

OUTLET STRUCTURE DETAIL

TOP OF STRUCTURE ELEVATION (SEE PROFILE)

A B.01

A

6" SUMP

OUTLET PIPE FL ELEV (SEE PROFILE)

PRECAST OPENING ELEVATION

PROVIDE FLEXIBLE, WATERTIGHT GASKET FOR PIPE OPENINGS

SEE SUDAS FOR SW-513 DETAILS

PRECAST STRUCTURE SHALL BE ONE SECTION OR

PROVIDE WATERTIGHT SEAL BETWEEN SECTIONS.

78" WALL

WIDTH

78" WALL WIDTH

1.25'

SEE SUDAS FOR SW-513 DETAILS

OUTLET PIPE

BEDDING PER SUDAS78" WALL WIDTH

2 LF 12" DUAL-WALL HDPE

12" HICKENBOTTOM INTAKE

OR APPROVED EQUAL

2 LF 12" DUAL-WALL HDPE

12" HICKENBOTTOM INTAKE OR APPROVED EQUAL

12" 90° ELBOW

EXCAVATED WETLAND POOL

EXCAVATE 1 FT ADDITIONAL AROUND INTAKE

PLACE RIP RAP IN 3-FT DIA. CIRCLE AROUND INTAKE

UNDERLAY WITH GEOTEXTILE (1.5 TN)

PLACE RIP RAP IN 6-FT DIA. CIRCLE AROUND INTAKE

UNDERLAY WITH GEOTEXTILE (1.5 TN)

AGRI DRAIN IN-LINE

WATER LEVEL CONTROL

STRUCTURE OR

APPROVED EQUAL

ATTACH TO CONCRETE

STRUCTURE

AGRI DRAIN IN-LINE WATER LEVEL CONTROL

STRUCTURE OR APPROVED EQUAL

STUB IN 12" PIPE

BACKFILL MIN. 1 FT AROUND

WCS WITH 1" CLEAN ROCK

NORMAL WATER LEVEL

9" INLET OPENING

ON ALL SIDES

6" x 6" CENTER

PIER ON ALL

SIDES

STRUCTURE LID PER SUDAS

FIT WITH SW-604 TYPE 5 CASTING

3 FT

SECTION

MODIFIED SW-513

OUTLET STRUCTURE

PLAN

MODIFIED SW-513

OUTLET STRUCTURE

NOT TO SCALE

NOT TO SCALE

NOTES:

1. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS

STEEL.

2. HICKENBOTTOM INTAKE, WATER LEVEL CONTROL

STRUCTURE, DUAL-WALL HDPE, ELBOW, TRASH GUARD,

CASTING, AND ALL HARDWARE AND APPURTENANCES

SHOWN ON THIS PAGE OR REQUIRED FOR INSTALLATION

ARE SUBSIDIARY TO THE OUTLET STRUCTURE.

36" RCP OUTLET PIPE

OPENINGS FOUR

SIDES WITH

CENTER PIERS

8" HDPE BASE FLOW RETURN PIPE

BASEFLOW RETURN PIPE FL ELEV (SEE PROFILE)

8" BASEFLOW RETURN PIPE

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

B0

1.

dw g 9/

/2

9:

:4

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.02

TRASH GUARD DETAIL

TRASH GUARD FOR WETLAND OUTLET STRUCTURE

48"

SHEET STEEL

SHEET STEEL

SHEET STEEL

90"

GROUND CONTACT

TREATED POST 4"x4"

OUTLET

STRUCTURE

12" MIN

SPACE

BELOW

GUARD

24"

CONCRETE FOOTINGS

MIN 12" DIAMETER

4 FT MIN.

EMBEDMENT

NOTE: TRASH GUARD AND APPURTENANCES ARE TYPICAL FOR ALL SIDES OF OUTLET STRUCTURE. QUANTITIES

AND DIMENSIONS FOR STEEL SHEETS PER SIDE OF STRUCTURE ARE AS FOLLOWS:

1 - STEEL SHEET - 90" x 24" x 3/8" 2 - STEEL SHEETS - 48" x 24" x 3/8"

ANGLE IRON--EITHER WELDED OR BOLTED--ON TOP AND BOTTOM OF EACH SHEET AS BRACE.

BOLT TRASH GUARD ONTO ANGLE IRON ANCHORED TO OUTLET STRUCTURE.

PROVIDE THREE POSTS WITH CONCRETE FOOTINGS ON EACH SIDE

GRADE AS NECESSARY TO ALLOW FLOW OF WATER UNDER TRASH GUARD WITH 12" MINIMUM CLEARANCE.

ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL

NOT TO SCALE

STRUCTURE

OPENING

SEE CONNECTION TO

STRUCTURE DETAIL

GRADE BELOW TRASH GUARD TO

PROVIDE 12" MINIMUM SPACE

BETWEEN BOTTOM OF STEEL AND

TOP OF RIP RAP (TYP. ALL SIDES)

CONCRETE STRUCTURE

SHEET STEEL

4" x 4" x 3/8" ANGLE

3/8" BOLT WITH CONCRETE ANCHOR

BOLTS SHALL BE PLACED IN THE CENTER OF THE WALL (TYP)

TRASH GUARD CONNECTION TO STRUCTURE

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

B0

1.

dw g 9/

/2

9:

:5

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.03

PUMP BASIN & SOLAR ARRAY DETAILS

3.5' 21' 3.5'

Included in kit Included in kit

10.5'

17'

4.5' to 5'

DPC2500

solar drive

250'

Solar + -

Solar disconnect

SOLAR ARRAY SUPPORT INSTALLATION DETAILS

NOTE:SOLAR PANELS SHALL BE INSTALLED IN THE LOCATION SHOWN ON A.03 AND

M.03 WITH A SOUTHWARD ORIENTATION.

SOLAR POWERED PUMP SYSTEM (BID ITEM 15) SHALL INCLUDE THE FOLLOWING:

· SOLAR PANELS

· SOLAR DRIVE

· 3-PHASE, 3 HP AXIAL PUMP (CARRY CP-04 WITH 17° IMPELLER OR APPROVED EQUAL,

PROVIDING 340 GPM AT 11.25 FT TDH)

· FLOAT SWITCH

· MOUNTING CLAMPS FOR CONTROLLER

· SOLAR PANEL MOUNTING KIT

· STEEL PIPE EXTENDERS

· WIRED GENERATOR PLUG

· LIGHTNING & SURGE PROTECTOR

· WIRING FOR PANELS, PUMP, AND CONTROLLER

CONTRACTOR SHALL PROVIDE THE FOLLOWING, SUBSIDIARY TO BID ITEM 15:

· STEEL PIPE FOR MOUNTING

· CONCRETE AND ROCK BEDDING FOR MOUNTING POLES

· PVC DISCHARGE PIPE

· CHECK VALVE

PUMP BASIN (BID ITEM 14) SHALL INCLUDE THE FOLLOWING:

· PUMP BASIN (MODIFIED SW-401, SEE DETAILS)

· STEEL LID WITH STAND

MOUNT PUMP CONTROLLER TO

SOLAR POSTS

SOLAR ARRAY SUPPORT

INSTALLATION DETAILS

NOT TO SCALE

PUMP WIRING DIAGRAM

NOT TO SCALE

15 FT

8 FT

PUMP CONTROLLER AND

SOLAR PANELS SHALL BE

ENTIRELY ABOVE THE

ELEVATION 1221.00

115 FT

INSTALL SOLAR DRIVES NEXT TO PUMPS

ON POSTS ABOVE 1221.00

PLACE 6" CLEAN 1" ROCK IN BOTTOM OF HOLE

FILL HOLE WITH CONCRETE

MIN. 12" DIAMETER

FLOW

NOT TO SCALE

SW-401 PUMP BASIN ELEVATION

EXTERIOR MASTIC &

FABRIC WRAP

ALL JOINTS - 9" WIDE

4'

16.5'

MIN. 12"

18" RCP

FL EL = 1207.00

PAINTED STEEL LID WITH ACCESS HATCH

TOP EL = 1220.00

8" PVC PUMP OUTLET

EL = 1218.00

EXISTING GROUND

APPROX. EL = 1218

NORMAL POOL = 1217.00

EMBANKMENT & WAVE BERM

8" MIN. CLASS I BEDDING MATERIAL

SUMP = 1201.50

SUDAS SW-401 STRUCTURE

2 FT

PLACE REVETMENT

SEE M.01

FLOAT ELEVATION

ON OFF

1207.50 1203.50

INSTALL PUMP CONTROL PANELS

ADJACENT TO PUMP BASIN OR ON

EMBANKMENT. MOUNT ON

POSTS ABOVE ELEVATION 1220.00

INSTALL CHECK VALVE

FLEXIBLE WATERTIGHT SEAL

4'

16.5'

18" RCP

FL EL = 1207.00

PAINTED STEEL LID WITH ACCESS HATCH

TOP EL = 1220.00

8" PVC PUMP OUTLET

EL = 1218.00

8" MIN. CLASS I BEDDING MATERIAL

SUMP = 1201.50

SUDAS SW-401 STRUCTURE

FLEXIBLE WATERTIGHT SEALS

NOT TO SCALE

SW-401 PUMP BASIN SECTION

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

B0

1.

dw g 9/

/2

9:

:5

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

B.04

CPDT INSTALLATION & ANTI-SEEP COLLAR DETAILS

FLAT BOTTOM TRENCH INSTALLATION

FILL TRENCH TO 6" ABOVE TOP OF PIPE WITH CRUSHED STONE OR GRAVEL

MEETING THE REQUIREMENTS IN TABLE 2. BEDDING MATERIAL SHALL BE

INCIDENTAL TO THE PIPE INSTALLATION.

PREFFERED TRENCH INSTALLATION BOTTOM

CORRUGATED POLYETHYLENE DRAINAGE TUBING

MATERIAL & INSTALLATION NOTES

NOT TO SCALE

SOURCE: ASTM F449

TRAPEZOIDAL GROOVE, "V" GROOVE, & CIRCULAR GROOVE

NOT TO SCALE

SOURCE: ASTM F449

6" MIN FOR

OPEN TRENCH

INSTALLATION

R

6" M

IN

A B G

0.

5R

0.

R

TRENCH WIDTH MEASURED

AT TOP OF PIPE

90° "V" GROOVE

90°

THE CIRCULAR GROOVE SHALL BE A

MINIMUM 0.35R DEEP AND SHALL

MATCH THE OUTSIDE CURVE

SHAPE OF THE DEFLECTED CPDT.

THE TRAPEZOIDAL GROOVE SHALL

BE SHAPED AND ADJUSTED SUCH

THAT POINTS A, B, & C WILL TOUCH

THE UNDEFLECTED CPDT FOR EACH

SIZE INSTALLED.

TRAPEZOIDAL GROOVE

CIRCULAR GROOVE

UNDISTURBED SOIL

UNDISTURBED SOIL

TRENCH WIDTH MEASURED

AT TOP OF PIPE

4" M

IN

SEE TABLE 2 FOR

BEDDING MATERIAL

NOTE: THIS IS AN ALLOWED ALTERNATIVE INSTALLATION FOR CPDT

1. ALL CPDT AND CONNECTORS FURNISHED SHALL BE IN COMPLIANCE WITH MATERIAL STANDARDS ASTM F405 AND F667, AS

APPLICABLE, AND SHALL BE CLASSIFIED AS HEAVY-DUTY UNDER THOSE STANDARDS.

2. EXCEPT MODIFIED HEREIN OR OTHERWISE APPROVED BY ENGINEER, ALL CPDT SHALL BE INSTALLED IN COMPLIANCE WITH THE

ASTM 449 STANDARD PRACTICE.

3. FOR PIPES 6” DIAMETER AND SMALLER A 90° V GROOVE BOTTOM MAY BE USED, FOR ALL LARGER PIPE A TRAPEZOIDAL BOTTOM OR A CIRCULAR BOTTOM CONFORMING TO THE OUTSIDE DIAMETER OF THE PIPE SHALL BE USED. PRIOR TO THE INSTALLATION OF CPDT, CONTRACTOR MUST PROVE TO ENGINEER THAT THE INSTALLATION REQUIREMENTS, INCLUDING THE

SHAPE OF THE TRENCH BOTTOM, WILL BE ACCOMPLISHED.

4. WHERE TRENCH BOTTOM IS IN FIRM UNDISTURBED SOIL, SHAPE TRENCH BASE GROOVE. WHERE EXCESS CUT OCCURS, OVEREXCAVATE AND PLACE MINIMUM THREE (3) INCH THICK, GRAVELLY SAND BEDDING TO RESTORE GRADE. THIS BEDDING SHALL MEET THAT REQUIRED FOR TRENCH INSTALLATION TYPE 3 ON PLAN SHEET C.02. IF DUE TO CONTRACTOR ERROR THIS MATERIAL AND WORK IS SUBSIDIARY TO THE INSTALLATION OF THE PIPE. CONTRACTOR MAY SUBSTITUTE PIPE BEDDING ROCK

AS THE BEDDING MATERIAL.

5. NATIVE SOILS MAY BE USED AS BACKFILL MATERIAL UNLESS UNSTABLE TRENCH CONDITIONS PREVENT THE TRENCH BOTTOM HOLDING THE SHAPED GROOVE. IF TRENCH BOTTOM WILL NOT HOLD GROOVE SHAPE CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY. A FLAT BOTTOM TRENCH INSTALLATION WILL THEN BE ASSUMED. THE REQUIRED BEDDING MATERIAL WILL BE

PAID UNDER THE TILE TRENCH STABILIZATION AND CRADLING ROCK BID ITEM.

6. MINIMUM TRENCH WIDTH IS PIPE OUTSIDE DIAMETER PLUS FOUR (4) INCHES FOR PLOWED INSTALLATION AND PIPE OUTSIDE

DIAMETER PLUS TWELVE (12) INCHES FOR OPEN TRENCH INSTALLATION.

7. ALL LATERAL CONNECTIONS, ELBOWS, TEES, ALIGNMENT CURVES, START HOLES AND ALL PORTIONS OF THE TRENCH NOT MEETING THE GROOVED TRENCH INSTALLATION REQUIREMENTS SHALL BE FILLED TO A MINIMUM OF SIX (6) INCH COVER OVER THE PIPE WITH GRADED CRUSHED STONE OR GRAVEL AS SHOWN ON TABLE 2 OF THIS SHEET. UNLESS DUE TO CONTRACTOR ERROR THIS BEDDING MATERIAL WILL BE PAID UNDER THE TILE TRENCH STABILIZATION AND CRADLING ROCK BID ITEM.

8. MANUFACTURER'S ENDCAPS SHALL BE INSTALLED AT THE TERMINATION OF EACH LINE UNLESS A CONNECTION TO AN EXISTING

DRAIN IS MADE.

9. WITH THE INSTALLATION OF THE FIRST REACH OF CPDT ON THE PROJECT, CONTRACTOR IS REQUIRED TO WORK WITH THE

ENGINEER TO CHECK AND CONFIRM THAT THE PIPE STRETCH, IF ANY, DOES NOT EXCEED 5%.

10. ALIGNMENT TURNS MAYBE MADE USING EITHER A MANUFACTURED FITTING OR CURVING THE LINE WITH A 25' MINIMUM

RADIUS.

R25'

PI

X °

PT

PT

Table 1 Maximum Allowable Buried Depth to Flowline of CPDT

Nominal Pipe Diameter (IN)

Pipe Quality

(ASTM)

Trench Width at Top of the Pipe (FT)

12" 18" 24" 30" or Greater

Standard 13 7 5.5 5

Heavy-duty Any 10 7 6

Standard 10 7 5.5 5

Heavy-duty Any 9.5 6.5 6

Standard 10 7 5.5 5

Heavy-duty Any 10 7 6

10 Heavy-duty ... 9 7 6 12 Heavy-duty ... 9 7 6 15 Heavy-duty ... ... 7 6

Table 2 Acceptable Bedding Material and Compaction Requirements

Description Percentage Passing Sieve Sizes Minimum

Standard Density (%)

Maximum Compaction Layer Height

(IN.)1" 3/4" No. 4

Crushed Stone Crushed Gravel* 100% > 95% < 5% Dumped 18

* Class 1 Bedding Material Per SUDAS 3010.202A is an Allowable Substitute

DEGREES Δ DELTA

20° 4.41 30° 6.7 45° 10.36 60° 14.43 70° 17.51 80° 20.98 90° 25

ALTERNATIVE 1: RCP ANTI-SEEP COLLAR

NOT TO SCALE

1/2" X 2" SLOTTED HOLES

FOR 3/8" DIA. BOLTS

CONTINUOUS WELD

BETWEEN BAND

AND COLLAR.

HEIGHT

PER

PLANS

HEIGHT

PER

PLANS

WIDTH SHOWN ON PLANS

SLOTTED HOLES

@ 8" O.C.

CONTINUOUS WELD

BETWEEN BAND

AND COLLAR.

BAND

BOTTOM OF BAND

2" 2"

BAND

A

A

12"

TOP OF BAND

BOTTOM OF COLLAR

CORRUGATED METAL SHEET WELDED

TO CENTER OF SMOOTH METAL

BAND WITH MASTIC APPLIED FOR

SEALANT AROUND THE PIPE.

OPTIONAL SUBSTITUTE -

CAST-IN-PLACE CONCRETE BAND.

ANTI-SEEP COLLAR DETAILS

ALTERNATIVE 2: COMPOSITE BENTONITE AGGREGATE COLLAR

NOT TO SCALE

12" ID

RCP

TRENCH WIDTH (SEE PLANS)

5 FT MIN. COLLAR WIDTH

FT

C O

LL

AR

TH

IC

KN

ES

S

NOTES:

1. COMPOSITE BENTONITE AGGREGATE (CBA) SHALL

BE AQUABLOK OR APPROVED EQUAL.

2. COLLAR SHALL EXTEND 1.75 FT BELOW BOTTOM OF

PIPE AND 1.75 FT ABOVE TOP OF PIPE. MINIMUM

DIMENSIONS ARE SHOWN ON THE PROFILE SHEET.

3. COLLAR SHALL BE A MINIMUM OF 5 FT WIDE AND

EXTEND A MINIMUM OF 6" BEYOND EDGE OF

TRENCH. MINIMUM DIMENSIONS ARE SHOWN ON

THE PROFILE SHEET.

4. NO COMPACTION OF CBA IS REQUIRED.

5. EXCAVATE AND BACKFILL THE REMAINDER OF THE

TRENCH AS NOTED IN THE PLANS.

CORRUGATED METAL SHEET

GALVANIZED STEEL

PREFABRICATED HPDE ANTI-SEEP

COLLARS ARE AN ALLOWED ALTERNATIVE.

BAND

ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

C0

1.

dw g 9/

/2

9:

:0

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR ESTIMATED QUANTITIES C.01

Bid Item Sub-Item Description Specifications Plan No. Estimated Quantities No. Page Quantity Unit

1 - Site Stripping & Preparation IA CS-001 3 N/A 1 LS 2 - Crop Damage IA CS-001 3 N/A 0 AC 3 - Structure & Channel Seeding IA CS-006 7 K.01 1.5 AC 4 - Buffer Seeding IA CS-006 7 K.01 0.9 AC 5 - Mobilization & Demobilization IA CS-008 11 N/A 1 LS 6 - Drain Tile Investigation and Removal IA CS-009 14 A.03 4 HR 7 - Excavation (General) IA CS-021 20 D.01 13310 CY 8 - Earthfill (General) IA CS-023 23 D.01, D.04 126 CY 9 - Earthfill (General Dam) IA CS-023 23 D.02-D.03 2767 CY

10 - Earthfill (Dam Core) IA CS-023 23 D.02-D.03 2023 CY 11 - Topsoil Strip, Salvage, and Respread IA CS-026 27 D.01 1635 CY 12 - Reinforced Concrete Pipe

C. 18" Diameter IA CS-031 29 M.01 120 LF D. 36" Diameter IA CS-031 29 M.01 130 LF

13 - SW-401 Pump Basin IA CS-031 29 B.02, M.01 1 EA 14 - Solar Pump System IA CS-031 29 B.03, M.01 1 EA 15 - Modified SW-513 Outlet Structure (78" x 78") IA CS-031 29 B.01, M.01 1 EA 16 - Concrete Apron, Footing, Bar Guard

A. 18" Diameter IA CS-031 29 M.01 1 EA B. 36" Diameter IA CS-031 29 M.01 1 EA

17 - 8" Dia. Corrugated HDPE Pipe (Dual-Wall, Non-Perforated) IA CS-046 36 B.04, M.02 954 LF 18 - CMP Tile Outlets (20 LF Each)

A. 10" Diameter IA CS-051 39 M.02 2 EA 19 - Anti-Seep Collars IA CS-051 39 M.01 6 EA 20 - Riprap (Class E) IA CS-061 43 M.01 29.3 TN

361238

12221224122612281232123412361238

22 1222

1222 1222

12181217 1216

122012201216

WEST DIVERSION BERM

TOP ELEV. 1216.50

4:1 SIDE SLOPE

EAST DIVERSION BERM

TOP ELEV. 1216.50

4:1 SIDE SLOPE

EXCAVATE TO 1216.00

POOL EXCAVATION GRADED TO

EXISTING SURFACE AT 4:1 SIDE SLOPE

10 FT WIDE EMBANKMENT

TOP ELEV. 1220.00

4:1 SIDE SLOPE

30 FT WIDE AUXILIARY SPILLWAY

CREST ELEV. 1218.50

3:1 SIDE SLOPE

PLACE EXCESS

SPOIL MATERIAL

EXCAVATE ADDITIONAL 1 FT

100 FT x 100 FT

ELEV. 1215.00

NORMAL POOL (1217.00)

100-YEAR HWL (1218.57)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 1216.00

MINIMUM 6" TOPSOIL LAYER

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

5, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

1.

dw g 9/

/2

9:

:0

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

D.01

GRADING OVERVIEW

R

FEETSCALE

0 40 80

HORZ.

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00

.4

.4

.1

.0

.8

.2

.6

.2

.9

.9

.8

.7

.7

.6

.2

.9

.1

.3

.2

.9

.1

.0

.7

.3

.8

.5

.1

.9

.8

.7

.7

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

STA: 0+89.25

ELEV: 1217.00

OVERBUILD

ELEV: 1220.07

OVERBUILD

ELEV: 1220.11

OVERBUILD

ELEV: 1220.14

OVERBUILD

ELEV: 1220.14

OVERBUILD

ELEV: 1220.17

OVERBUILD

ELEV: 1220.24

10 FT WIDE EMBANKMENT

TOP ELEV. 1220.00

AUXILIARY SPILLWAY SURFACE

EXISTING SURFACE

BOTTOM OF CORE TRENCH

5 FT BELOW EXISTING GRADE

NWL & TOP OF DAM CORE

ELEV. 1217.00

POOL EXCAVATION ELEV. 1216.00

STA: 0+89.25

ELEV: 1220.00

STA: 1+10.00

ELEV: 1220.00

STA: 1+61.24

ELEV: 1220.00

18" RCP PUMP INLET PIPE

SEE M.01

0+

1+

2+00

3+00

4+00

5+00

6+00

7+00

8+00

BP: 0+00.00

PC: 1+19.13

PT

: 2

+2 0.

PC

: 8

+4 0.

12181219

BEGIN EMBANKMENT AND WAVE BERM

30 FT AUXILIARY SPILLWAY

SEE D.03

18" RCP PUMPED INLET PIPE

SEE M.01

MODIFIED SW-401

PUMP BASIN

SEE B.02

NORMAL POOL (1217.00)

100-YEAR HWL (1218.80)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 1216.00

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

2.

dw g 9/

/2

9:

:2

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 25 50

HORZ.

FEETSCALE

0 5 10

VERT. D.02

EMBANKMENT PLAN & PROFILE

10 FT WIDE TOP (4.5 FT ABOVE NWL)

10 FT WAVE BERM (AT NWL)

5 FT MIN. CORE TRENCH WIDTH

(TOP AND BOTTOM)

NORMAL WATER LEVEL

TOP OF CORE TRENCH

AT NWL

1:1 MAX SLOPES

4:1

4:1

EMBANKMENT CROSS SECTION

NOTE: ONLY BUILD WAVE

BERM ADJACENT TO POOL

BOTTOM OF CORE TRENCH

5 FT BELOW EXISTING GRADE

EXCAVATED POOL

NOT TO SCALE

NOTE: EMBANKMENT SHALL BE

OVER-BUILT BY 5% OF FILL HEIGHT.

THE OVERBUILD FILL VOLUME IS NOT

INCLUDED IN THE PLAN QUANTITIES.

EMBANKMENT

8+00 9+00 10+00 11+00 11+50

.7

.9

.0

.7

.0

.4

.7

.0

.3

.5

.4

.4

.6

.5

.8

.2

.1

.1

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

.0

STA: 11+18.47

ELEV: 1217.00

OVERBUILD

ELEV: 1220.15

OVERBUILD

ELEV: 1220.08

OVERBUILD

ELEV: 1220.07

10 FT WIDE EMBANKMENT

TOP ELEV. 1220.00

EXISTING SURFACE

BOTTOM OF CORE TRENCH

5 FT BELOW EXISTING GRADE

NWL & TOP OF DAM CORE

ELEV. 1217.00

POOL EXCAVATION ELEV. 1216.00

STA: 11+18.47

ELEV: 1220.00

36" RCP OUTLET PIPE

SEE M.01

7+

8+

9+00

10+00

+0

11+50

PC: 8+40.96

PT: 8+95.13

PC: 9+65.95

PT: 10+13.81

EP: 11+50.00

1216 >>>>>>>>>>

15 12

17 12

19 12

12161217

END EMBANKMENT AND WAVE BERM

36" RCP OUTLET PIPE

SEE M.01

MODIFIED SW-513

OUTLET STRUCTURE

SEE B.01

-0+50 0+00 1+00 2+00 2+75

.9

.9

.9

.8

.1

.0

.7

.7

.7

.4

.5

.3

.9

.8

STA: 0+35.29

EL: 1218.50

STA: 0+63.13

EL: 1218.50

STA: 0+98.82

EL: 1217.96

STA: 1+43.98

EL: 1217.73

0.00% -1.50% -0.52%

10 FT EMBANKMENT

EXCAVATED POOL

NWL = 1217.00

EXISTING SURFACE

30 FT WIDE AUXILIARY SPILLWAY

CREST ELEV. 1218.50

WAVE BERM

0+

1+00

2+00

2+25

BP: 0+00.00

PC: 0+34.07

PT

: 0

+9 8.

EP

: 2

+2 5.

221224

PUMPED INLET PIPE

SEE M.01

NORMAL POOL (1217.00)

100-YEAR HWL (1218.80)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 1216.00

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

2.

dw g 9/

/2

9:

:3

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 25 50

HORZ.

FEETSCALE

0 5 10

VERT. D.03

EMBANKMENT (CONT.) & AUXILIARY SPILLWAY

R

30 FT BOTTOM

3:1 SIDES

TOP OF EMBANKMENT

EXISTING

GROUND

AUXILIARY SPILLWAY SECTION THROUGH EMBANKMENT

EMBANKMENT AUXILIARY SPILLWAY

NOTE: EMBANKMENT SHALL BE

OVER-BUILT BY 5% OF FILL HEIGHT.

THE OVERBUILD FILL VOLUME IS NOT

INCLUDED IN THE PLAN QUANTITIES.

-0+75 0+00 1+00 2+00 2+75

.7

.4

.2

.9

.7

.5

.3

.4

.5

.9

.5

.5

.5

.5

.5

.5

.5

.5

STA: 0+18.00

EL: 1216.00

STA: 0+20.00

EL: 1216.50

STA: 2+04.05

EL: 1216.50

EXISTING SURFACE 10 FT DIVERSION BERM

TOP ELEV. 1216.50

EXCAVATED POOL

NWL = 1217.00

EMBANKMENT &

WAVE BERM

4:1 0+00 1+00 2+00 2+25

BP

: 0

+0 0.

EP

: 2

+2 5.

12161217121812191220

PUMPED INLET PIPE

SEE M.01

0+00 1+00 2+00

BP

: 0

+0 0.

EP

: 2

+0 0.

1215 12

18 12

-0+75 0+00 1+00 2+00 2+75

.7

.3

.2

.5

.4

.3

.3

.1

.9

.5

.5

.5

.5

.5

.5

.5

STA: 0+23.00

EL: 1216.00

STA: 0+25.00

EL: 1216.50

STA: 1+84.02

EL: 1216.50

EXISTING SURFACE

10 FT DIVERSION BERM

TOP ELEV. 1216.50

EXCAVATED POOL

NWL = 1217.00

EMBANKMENT &

WAVE BERM

4:1

NORMAL POOL (1217.00)

100-YEAR HWL (1218.80)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 1216.00

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

D0

2.

dw g 9/

/2

9:

:3

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 25 50

HORZ.

FEETSCALE

0 5 10

VERT. D.04

DIVERSION BERMS

R

WEST DIVERSION BERM EAST DIVERSION BERM

10 FT WIDE TOP

6" BELOW NWL

NORMAL WATER LEVEL

DIVERSION BERM CROSS SECTION

EXISTING/EXCAVATED

GROUND SURFACE

4:1 SIDE SLOPES

SEED EMBANKMENT

STRUCTURE SEEDING

SEED AUXILIARY SPILLWAY

AND SURROUNDING AREA

STRUCTURE SEEDING

SEED 4:1 SLOPES WITH STRUCTURE SEEDING

TO 1 FT BELOW NORMAL POOL

SEED TO EASEMENT BOUNDARY

BUFFER SEEDING

SEED TO EXISTING FIELD EXTENTS

BUFFER SEEDING

SEED TO EXISTING FIELD EXTENTS

BUFFER SEEDING

SEED EMBANKMENT

STRUCTURE SEEDING

SEED 4:1 SLOPES TO 1 FT

BELOW NORMAL POOL

STRUCTURE SEEDING

SEEDING AREAS

BUFFER SEEDING 0.9 AC

STRUCTURE SEEDING 1.5 AC

NOTE: ANY ADDITIONAL

DISTURBED AREAS SHALL BE

SEEDED WITH BUFFER SEEDING.

DO NOT SEED POOL

12221224 12261228

1232123412361238

1222 12

241226

1210 1210

1212 1212

121512201220

12161216

12171218

12191219

12201216121712181219

SEED WAVE BERM

STRUCTURE SEEDING

SEED WAVE BERM

STRUCTURE SEEDING

DO NOT SEED DIVERSION BERM

DO NOT SEED DIVERSION BERM

NORMAL POOL (1217.00)

100-YEAR HWL (1218.80)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 1216.00

STRUCTURE SEEDING

BUFFER SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

K0

1.

dw g 9/

/2

9:

:4

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

K.01

SEEDING PLAN

R

FEETSCALE

0 40 80

HORZ.

-0+50 0+00 1+00 2+00 3+00

.5

.8

.3

.5

.5

.1

.8

.2

.6

.1

.4

.1

.8

.5

.1

ST

A

0+

" A

PR

O

N , F

O O

TI

N

G, B

AR

G

U

AR

D

FL

O U

T

.5

(1 8"

S W

120' - 18" RCP @ 1.30%

120 LF - 18" RCP

@ 1.30% 6444

PU

M

P

BA

SI

N

(S

TA

+6

4) M

O

DI

FI

ED

S W

-4

(4 8i n)

TO

P

.0

FL

IN

7.

(1

8" N

E)

EXCAVATED POOL

NWL = 1217.00

EMBANKMENT

TOP ELEV. 1220.00EXISTING SURFACE

-1.30%

VPI: 0+44.02

EL: 1208.55

VPI: 1+63.63

EL: 1207.00

ANTI-SEEP COLLARS

6 FT HEIGHT x 10.25 FT WIDTH

SEE B.04

121012

121212

121412

1216 12

122212

20 12

20 12

STA 0+44

18" APRON, FOOTING, BAR GUARD

FL OUT = 1208.55 (18" SW)

0+00 1+00 2+00 2+25

BP

: 0

+0 0.

EP

: 2

+2 5.

PUMP BASIN (STA 1+64)

MODIFIED SW-401 (48in)

TOP = 1219.00

FL IN = 1207.00 (18" NE)

RIP RAP

7.9 TONS

PLACE SOLAR PANELS

ABOVE ELEV. 1221.00

RIP RAP

4.0 TONS

30 FT AUXILIARY SPILLWAY

SEE D.03

-0+50 0+00 1+00 2+00 3+00

.0

.8

.9

.8

.6

.6

.1

.8

.2

.7

.4

.1

.8

.5

128' - 36" RCP @ 1.17%

128 LF - 36" RCP

@ 1.17% 7851

-1.17%

VPI: 0+50.66

EL: 1210.00

VPI: 1+78.38

EL: 1208.50

O U

TL

ET

S

TR

U

CT

U

RE

(S

TA

+5

1) M

O

DI

FI

ED

S W

-5

SE

E

B.

TO

P

.2

O

PE

N

IN

G:

7.

CA

ST

IN

G

SW

-6

T

YP

E

FL

O

U T

.0

(3

6" N

E)

FL

O U

T

.0

(8 " N

W

ST

A

1+

" A

PR

O

N , F

O O

TI

N

G, B

AR

G

U

AR

D

FL

IN

8.

(3 6"

S W

EXCAVATED POOL

NWL = 1217.00

EMBANKMENT

TOP ELEV. 1220.00

EXISTING SURFACE

ANTI-SEEP COLLARS

7.5 FT HIGH x 12 FT WIDE

SEE B.04

20 12

16 12

18 12

10 12

12 12

121214

14 12

16 12

>> >> >> >> >>0+00 1+00 2+00 2+25

BP

: 0

+0 0.

EP

: 2

+2 5.

OUTLET STRUCTURE (STA 0+51)

MODIFIED SW-513

SEE B.01

TOP = 1218.25

OPENING = 1217.00

CASTING = SW-604 TYPE 5

FL OUT = 1210.00 (36" NE)

FL OUT = 1209.00 (8" NW)

STA 1+78

36" APRON, FOOTING, BAR GUARD

FL IN = 1208.50 (36" SW)

RIP RAP

1.5 TONS

8" HDPE POND OUTLET PIPE

SEE M.02

RIP RAP

10.8 TONS

NORMAL POOL (1217.00)

100-YEAR HWL (1218.80)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 1216.00

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

M

.d w g

9/

/2

9:

:5

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

FEETSCALE

0 25 50

HORZ.

FEETSCALE

0 5 10

VERT. M.01

PUMP INLET & OUTLET PIPES

R

R

PUMPED INLET PIPE OUTLET PIPE

-0.20%

VPI: 0+25.00

EL: 1209.00 VPI: 4+14.32

EL: 1208.22

ST

A

0+

M O

DI

FI

ED

S

W -5

SE

E B.

FL

O U

T

.0

(3 6"

N E)

FL

O

U T

.0

(8

" N W

369' - 8" HDPE @ 0.20%

369 LF - 8" HDPE

@ 0.20% 9425

20' - 10" CMP @ 0.20%

20 LF - 10" CMP

@ 0.20% 1494

EXCAVATED POOL

NWL = 1217.00

EMBANKMENT

TOP ELEV. 1220.00

EXISTING GROUND SURFACE

0+00

1+00

2+00

3+00 4+00

4+25

BP: 0+00.00

PC: 0+29.18

PT: 0+42.85

PC: 0+87.61

PT: 1+20.63

PC: 3+55.05

PT: 3+94.32

EP: 4+25.00

12061208

OUTLET STRUCTURE (STA 0+51)

MODIFIED SW-513

SEE B.01

TOP = 1218.25

OPENING = 1217.00

CASTING = SW-604 TYPE 5

FL OUT = 1210.00 (36" NE)

FL OUT = 1209.00 (8" NW)

RIP RAP

1.5 TONS

8" HDPE POND OUTLET PIPE

SEE M

.02

RIP RAP

10.8 TONS

NORMAL POOL (1217.00)

100-YEAR HWL (1218.80)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 1216.00

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

M

.d w g

9/

/2

9:

:0

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 25 50

HORZ.

FEETSCALE

0 5 10

VERT. M.02

-0+50 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00

.9

.6

.0

.8

.3

.3

.0

.4

.0

.6

.9

.3

.4

.2

.0

.4

.3

.2

.5

.4

.2

.0

.6

.6

.6

.7

.2

.9

.7

.5

.2

.0

.7

.5

.2

.0

.7

.5

.2

.0

.8

.5

.3

.0

.8

.5

.3

.0

.8

.6

-0.98%

VP

I:

0+

.0

EL

: 1

3.

VP

I:

6+

.1

EL

: 1

7.

ST

A 6+

L F

CM

P

TI

LE

O U

TL

ET

FL

IN

7.

(1

0" S

ST

A

0+

CO

N

N

EC

T

TO

E

XI

ST

IN

G O

U

TL

ET

S

TR

U

CT

U

RE

FL

O U

T

.3

(8 " N

20' - 10" HDPE @ 0.98%

20 LF - 10" CMP

@ 0.98%

EXISTING SURFACE

REUSE EXISTING OUTLET STRUCTURE

20 LF CMP TILE OUTLET

ST

A

3+

BE

GI

N C

U

RV

E

F T

RA

DI

U S

FL

IN

0.

(8

" W

FL

O

U T

.1

(8

" E

ST

A

3+

EN

D

CU

RV

E

F T

RA

DI

U S

FL

IN

9.

(8

" S

FL

O

U T

.6

(8

" N

ST

A

0+

4°

B

EN

D

FL

IN

3.

(8 " S

FL

O U

T

.1

(8 " E

580' - 8" HDPE @ ???

580 LF - 8" DUAL-WALL, NON-PERF. HDPE

(FLEXCORR OR APPROVED EQUAL)

@ 0.98% 9010

0+

1+

BP: 0+00.00

PC: 0+29.18

PT: 0+42.85

PC: 0+87.61

PT: 1+20.6312

18 1210

12101206

12081212

0+00

1+00

2+00

3+00

4+00

5+00

6+00

6+42.19

BP: 0+00.00

PI: 0+30.00

PC

: 3

+3 9.

PT: 3+89.31

EP: 6+42.19

STA 0+10

CONNECT TO EXISTING

OUTLET STRUCTURE

FL OUT = 1213.38 (8" N)

STA 6+10

20 LF CMP TILE OUTLET

FL IN = 1207.50 (10" S)

STA 3+89

END CURVE

40 FT RADIUS

FL IN = 1209.66 (8" S)

FL OUT = 1209.66 (8" N)

STA 3+39

BEGIN CURVE

40 FT RADIUS

FL IN = 1210.16 (8" W)

FL OUT = 1210.16 (8" E)

36" RCP OUTLET PIPE

SEE M.01

RIP RAP

5.1 TONS

NORMAL POOL (1217.00)

100-YEAR HWL (1218.80)

PROPOSED EASEMENT BOUNDARY

RIP-RAP

EXCAVATE TO 1216.00

STRUCTURE SEEDING

LEGEND

SHEET

B ol to n

M en k, In c.

6, A ll Ri gh ts

R es er ve d c H:

\I

DA

LS

\2

5X

0\

CA

D\

C3 D\

M

.d w g

9/

/2

9:

:0

AM

DESIGNED

DRAWN

CHECKED

CLIENT PROJ. NO.

DATEDESCRIPTION REV IOWA DEPARTMENT OF AGRICULTURE AND LAND STEWARDSHIP

CAR833409A - THRILLS HILLS WETLAND

BCS

NVD

JPR

25X.137945.000

1.0 PERMIT PLANS 05/29/20261519 BALTIMORE DRIVE

AMES, IA 50010

Phone: (515) 233-6100 Email: Ames@bolton-menk.com www.bolton-menk.comR

R

FEETSCALE

0 25 50

HORZ.

FEETSCALE

0 5 10

VERT. M.03

POND OUTLET PIPE

POND OUTLET PIPE

Sheets and Views
A.01 TITLE SHEET
A.02 PLAN OVERVIEW SHEET
A.03 EXISTING CONDITIONS
B.01 OUTLET STRUCTURE DETAIL
B.02 TRASH GUARD DETAIL
B.03 PUMP BASIN & SOLAR ARRAY DETAILS
B.04 CPDT INSTALLATION & ANTI-SEEP COLLAR DETAILS
C.01 ESTIMATED QUANTITIES
D.01 GRADING OVERVIEW
D.02 EMBANKMENT PLAN & PROFILE
D.03 EMBANKMENT (CONT.) & AUXILIARY SPILLWAY
D.04 DIVERSION BERMS
K.01 SEEDING PLAN
M.01 PUMP INLET & OUTLET PIPES
M.02 RETURN PIPE
M.03 POND OUTLET PIPE
2026-09-29T09:53:39-0500
Brandon Short

File details come from the government source that posted it. Updated .