This document is a finishes specification sheet for an interior construction project managed by NAVFAC (Naval Facilities Engineering Command). It outlines approved basis of design specifications for paint, flooring, transitions, and related interior finishes for a federal facility renovation.

The specification details include: primary wall paint (Benjamin Moore 1548 Classic Gray), accent paint for sleeping rooms (Benjamin Moore 1552 River Reflections), door frame paint (Sherwin Williams SW 7026 Griffin), and drywall/exposed ceiling paint (Sherwin Williams SW 7102 White Flour). Flooring specifications include luxury vinyl tile in sleeping rooms (Mannington Crisscross Zoom Charcoal) and offices (Mannington Access Stone Linear Stone Shale), epoxy resinous flooring for lounge and shared spaces (Dur-A-Flex Dur-A-Quartz Q28-23), and rubber base (Johnsonite 283 Toast). Transition strips and corner guards are specified by Schluter and Inpro respectively. The document emphasizes that listed manufacturers establish the basis of design for color, pattern, and texture characteristics only and are not intended to limit product selection from other manufacturers, provided substitutes meet specified criteria and receive approval from the Project Manager and NAVFAC Contracting Officer. Key contractor responsibilities include ordering all materials timely to avoid delays, installing all materials per manufacturer requirements, ensuring all interior finishes in vertical exit ways meet minimum Class A fire ratings, spray painting (not brush painting) electrical panels and access panels to match adjacent wall colors, and ensuring all flooring transitions comply with ABA guidelines with transitions under doors centered.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAME LOCATION MANUFACTURER MODEL COLOR SIZE

PAINT PRIMARY WALLS BENJAMIN MOORE 1548 CLASSIC GRAY -

ACCENT PAINT SLEEPING ROOMS BENJAMIN MOORE 1552 RIVER REFLECTIONS -

PAINT DOOR FRAMES SHERWIN WILLIAMS SW 7026 GRIFFIN -

PAINT GWB & EXPOSED CEILINGS SHERWIN WILLIAMS SW 7102 WHITE FLOUR -

WALL GRAPHIC LOUNGE FIND YOUR LEVEL LINDSEY II BEIGE -

LUXURY VINYL TILE SLEEPING ROOMS MANNINGTON CRISSCROSS ZOOM CHARCOAL -

LUXURY VINYL TILE OFFICES MANNINGTON ACCESS STONE LINEAR STONE SHALE -

RUBBER BASE PRIMARY BASE JOHNSONITE 283 TOAST -

TRANSITION STRIP LVT TO TILE SCHLUTER RENO-U AEU 35 SATIN ANODIZED -

TRANSITION STRIP LVT TO CONCRETE OR EPOXY SCHLUTER RENO-U AEU 100 SATIN ANODIZED -

CORNER GUARD OUTSIDE CORNERS INPRO TYPE 430 STAINLESS STEEL -

EPOXY RESINOUS FLOORING LOUNGE & SHARED SPACES DUR-A-FLEX DUR-A-QUARTZ Q28-23 -

GENERAL NOTES

• FINISHES INDICATED ARE THE APPROVED BASIS OF

DESIGN TO CONVEY COLOR, PATTERN, TEXTURE AND

SALIENT CHARACTERISTICS ONLY. THE LISTING OF

MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT

THE SELECTION OF PRODUCTS PROVIDED BY OTHER

MANUFACTURERS. PRODUCTS MEETING THESE CRITERIA

WILL BE CONSIDERED AND MUST BE REVIEWED BY THE

PROJECT MANAHGER AND APPROVED BY THE NAVFAC

CONTRACTING OFFICER.

FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO

AVOID DELAYS.

• FINISH ITEMS ARE NOT TO BE SUBSTITUTED DUE TO

ORDERING LEAD TIMES. IT IS THE CONTRACTOR ’S

RESPONSIBILITY TO ORDER ALL MATERIALS IN TIME TO

AVOID DELAYS.

• ALL INTERIOR FINISHES IN VERTICAL EXIT WAYS, EXIT

LOBBIES, AND EXIT CORRIDORS MUST MEET MINIMUM

CLASS A RATING.

• SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND

EXPANSION JOINTS TO MATCH THE ADJACENT WALL

COLOR. PANELS PAINTED BY BRUSH ARE NOT

ACCEPTABLE.

• ALL MATERIALS/PRODUCTS ARE TO BE INSTALLED PER

MANUFACTURER'S INSTALLATION REQUIREMENTS.

• ALL FLOORING TRANSITIONS MUST MEET ABA

GUIDELINES. FLOORING TRANSITIONS OCCURRING UNDER

DOORS MUST BE CENTERED UNDER DOOR.