25M013MZ Building RR631-RR633-RR635 Flooring Repairs SOW.pdf

PDF 131 KB Posted

Attached to
Flooring Repair Buildings RR631-RR-633-RR635
Solicitation number
N4008526R9024
Issued by

About this file

This is a Statement of Work (SOW) for a flooring repair project at Camp Lejeune, North Carolina, covering Buildings RR631, RR633, and RR635.

The contractor shall remove all existing luxury vinyl plank (LVP) flooring throughout the three buildings and seal the floors with Ardex floor sealer or a comparable product meeting or exceeding manufacturer specifications. The contractor must then install Tarkett Provence 2131 6" x 48" luxury vinyl tile (LVT) or a comparable product, along with Johnsonite Medium Gray wall base. All work shall be performed to manufacturer specifications, and the contractor is responsible for taking field measurements, providing all materials, labor, equipment, and supervision. The contractor shall replace any thresholds between carpet and other flooring as needed, replace any vinyl wall base that is disturbed, and apply sealant before flooring installation. All debris must be properly removed, hauled, and disposed of by the contractor—not through the Camp Lejeune dumpster—and all over-spray, drips, splatters, and spills must be cleaned. The contractor shall also repair or refinish any areas damaged or disturbed by the new work. Product submittals including manufacturer specifications and technical data must be submitted to the contracting officer marked with the project number. The flooring contractor must provide a 5-year warranty for defects in materials and workmanship and a 25-year non-prorated limited warranty against excessive surface wear, static, delamination, edge ravel, zippering, and backing resilience. The primary point of contact is Zachory Melchisky at 910-440-0558.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MACC No. 25-0455 PROJECT No. 25M013MZ MAXIMO No. 5484607

TITLE: Building RR631, RR633, RR635 Flooring Repair Project

ATTACHMENTS: 1. Drawings, Scope and Specs.

SCOPE OF WORK: The contractor shall provide all material, labor, equipment, and supervision required to accomplish the following:

GENERAL DESCRIPTION: This scope of work is to be accomplished at Building RR631, RR633, RR635 located on Everett Creek Road at Camp Lejeune, North Carolina.

GENERAL SPECIFICATIONS: The contractor shall follow the general specifications unless noted in the project area description section. All measurements on the attached sketches are for reference use only. The contractor shall take their own field measurements in determining required material and costs. All work performed shall meet or exceed SPECIFICATIONS THAT

ARE ATTACHED.

PROJECT AREA DESCRIPTIONS: See attached Work Area Sketches for additional details.

1. RR631, RR633, RR635 Remove all LVP flooring in thru out buildings.

2. Seal floors with Ardex floor sealer or comparable product that meets or exceeds manufacturers specifications.

3. Install Tarkett Provence 2131 6”x 48” LVT or comparable product that meets or exceeds manufacturers specifications.

4. Install Johnsonite Medium Gray wall base or comparable product that meets or exceeds manufacturers specifications.

PREPARATION:

1. The contractor shall take the necessary precautions to prepare and protect personal property, government property, and work areas during the accomplishment of work for this scope.

INTERIOR FLOOR CARPET, WAX, BUFF AND REPAIRS:

1. Contractor shall replace any threshold between carpet and other flooring as needed.

2. Existing flooring should be removed and replaced to manufactures specifications.

3. Replace any vinyl wall base that is disturbed.

4. Sealant shall be applied before flooring is installed.

SPECIAL CONDITIONS

1. Clean all over-spray, drips, splatters, and spills resulting from accomplishing work for this project.

2. Repair, refinish areas damaged or disturbed by new work to be provided under this contract.

3. Properly remove, haul, and dispose of all debris. The contractor shall not utilize the dumpster provided by Camp Lejeune for the occupants.

SCHEDULING AND ACCESS:

• The Primary Point of Contact for the buildings are as follows: Zachory Melchisky at 910- 440-0558

ENVIRONMENTAL REQUIREMENTS: None Identified

SUBMITTALS:

1. The contractor shall submit to the contracting officer, the manufacturer’s product specifications, complete with technical products data being used for this project.

2. Submittal should be marked for project number.

MATERIAL SPECIFICATIONS:

1. RESILIENT FLOORING

a. See attached specifications.

2. SEALANT

a. See attached specifications.

WARRANTY:

1) Flooring contractor shall provide a 5- year warranty for defects in materials and workmanship and provide a 25-year non-prorated limited warranty against excessive surface wear and static, delamination, edge ravel, zippering, and backing resilient.

PREPARATION:
INTERIOR FLOOR CARPET, WAX, BUFF AND REPAIRS: