25BA011 Supplemental drawings.pdf
PDF 5 MB Posted
- Solicitation number
- W912EF25BA011
About this file
The file contains a set of supplemental technical drawings for the Charbonneau Park infrastructure project at Ice Harbor Lock and Dam, located in Walla Walla, Washington. The drawings provide detailed engineering plans for various utility systems, including:
Comprehensive site plans and technical specifications cover water and sewer distribution, electrical systems, irrigation, and sanitary facilities. The drawings include detailed schematics for electrical site plans, water and sewer piping, septic tank configurations, distribution panels, control systems, and utility connections. The project appears to be a comprehensive upgrade of the park's infrastructure, with precise engineering documentation from the U.S. Army Corps of Engineers, Walla Walla District, focusing on improving utility services and infrastructure at the Charbonneau Park location near the Snake River.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FILE NAME SUBJECT TITLE FILE NO.
04c36003.tif CHARBONNEAU PARK - SEWAGE TREATMENT UPGRADE SITE PLAN, DRAIN FIELD DETAILS, AND PAVEMENT REPAIR DETAILS IHG-1-8-10/1 09c46-40.tif BUILDINGS & GROUNDS-ELECTRICAL CHARBONNEAU PARK POTABLE WATER SYSTEM SCHEDULES AND DIAGRAMS ONE LINE DIAGRAM PANEL P & PP IHB-1-6-0/5 09c51-26.tif FOR INFORMATION ONLY - ELECTRICAL UPGRADES - CHARBONNEAU PARK - CHARBONNEAU PARK - IRRIGATION AND SPRINKLER SYSTEM CHARBONNEAU PARK - IRRIGATION AND SPRINKLER SYSTEM IHG-9-3-10/2 ihgj8005.tif CHARBONNEAU PARK WATER CRAFT SANITARY SERVICE STATION PLAN, SECTIONS & DETAILS IHG-1-3-6/10 ihgj8022.tif GENERAL-GENERAL PLANS & LAYOUT ADDITIONAL SANITATION FACILITIES LUCKY PEAK LAKE FISHHOOK PARK & CHARBONNEAU PARK CHARBONNEAU PARK UTILITY SYSTEM DISTRIBUTIO IHG-1-0-10/88 ihgj8030.tif CHARBONNEAU PARK PUMPHOUSE 2 LOCATION MAP & INDEX TO DRAWINGS (ELECTRICAL FEED) IHG-1-0-1/135 ihgj8058.tif GENERAL-GENERAL PLANS & LAYOUT ADDITIONAL SANITATION FACILITIES LUCKY PEAK LAKE FISHHOOK PARK & CHARBONNEAU PARK CHARBONNEAU PARK SITE PLAN IHG-1-0-10/87 ihgj8063.tif GENERAL-GENERAL PLANS & LAYOUT ADDITIONAL SANITATION FACILITIES LUCKY PEAK LAKE FISHHOOK PARK & CHARBONNEAU PARK CHARBONNEAU PARK 35 SLC COMFORT STATION ELE IHG-1-0-10/94 ihgj8064.tif GENERAL-GENERAL PLANS & LAYOUT ADDITIONAL SANITATION FACILITIES LUCKY PEAK LAKE FISHHOOK PARK & CHARBONNEAU PARK CHARBONNEAU PARK 35 SLC COMFORT STATION MEC IHG-1-0-10/95 ihgj8072.tif PUBLIC USE & ACCESS FACILITIES CHARBONNEAU PARK ELECTRICAL DETAILS MAIN DISTRIBUTION PANEL, PANELBOARD & CONTROL SCHEMATIC IHG-1-6-10/6 ihgj8076.tif CHARBONNEAU PARK WATERCRAFT SANITARY SERVICE STATION ELECTRICAL I IHG-1-6-6/21 ihgj8077.tif CHARBONNEAU & HOOD PARKS MECHANICAL WATER & SEWER DISTRIBUTION PAVING & UNDERGROUND UTILITIES IHG-1-0-10/119 IRRIGATION AND SPRINKLER SYSTEM.pdf WATER WELL 1 AND TWO.pdf
SUPPLEMENTAL DRAWING INDEX
| 04c36003 |
| 09c46-40 |
| 09c51-26 |
| ihgj8005 |
| ihgj8022 |
| ihgj8030 |
| ihgj8058 |
| ihgj8063 |
| ihgj8064 |
| ihgj8072 |
| ihgj8076 |
| ihgj8077 |
| IRRIGATION AND SPRINKLER SYSTEM |
| WATER WELL 1 AND TWO |
File details come from the government source that posted it. Updated .