About this file

This is a Pre-Renovation Limited Asbestos and Lead-Containing Paint Survey Report prepared by Atlas Technical Consultants LLC for the Michigan Department of Military & Veterans Affairs, Reserve Forces Support Center, regarding the Waterford Armory located at 2650 Watkins Lake Road in Waterford, Michigan. The survey was conducted from May 27 through June 3, 2025, by State of Michigan Certified Asbestos Inspector Rachel Kasnow (Certification No. A61030) to identify and collect samples of suspect asbestos-containing materials (ACMs) and lead-containing paint (LCP) prior to demolition activities. The inspection included a visual survey of the building structures, identification of 104 homogeneous areas, and collection of 312 asbestos bulk samples and 11 lead-containing paint chip samples. Additionally, six lead dust wipe samples were collected from surfaces within and directly connected to the shooting range area. The report was completed and submitted on June 19, 2025.

Laboratory analysis of the asbestos samples using Polarized Light Microscopy (PLM) by Environmental Testing Laboratories, Inc. (NVLAP #201028-0) identified five samples containing greater than 1 percent asbestos and four additional samples assumed to contain asbestos. All eleven paint chip samples analyzed using Flame AAS by Accurate Analytical Testing Laboratory contained lead levels greater than the laboratory reporting limits, with concentrations ranging from 0.00185 percent to 0.482 percent by weight. Lead dust wipe sampling results indicated that two of the six samples exceeded USEPA HUD standards for floors. The survey noted that any additional suspect materials discovered during renovation or demolition activities must be assumed to contain asbestos until sampling and analysis proves otherwise, and should be handled in accordance with OSHA regulations 29 CFR 1926.1101, the Asbestos Hazard and Emergency Response Act of 1987 (AHERA), and applicable state and local regulations.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRE-RENOVATION LIMITED ASBESTOS AND LEAD-CONTAINING PAINT SURVEY

WATERFORD ARMORY

2650 WATKINS LAKE ROAD

JACKSON, MI 48328

Project #188BS25305

PREPARED FOR:

Michigan Department of Military & Veterans Affairs Reserve Forces Support Center

PREPARED BY:

Atlas Technical Consultants LLC 46555 Humboldt Drive, Suite 100 Novi, Michigan 48377 June 19, 2025

Page | 1

46555 Humboldt Drive, Suite 100 Novi, Michigan 48377

(248) 669-5147 | oneatlas.com

June 19, 2025

Mr. Timothy Cole State of Michigan Buyer Michigan Department of Military & Veterans Affairs Reserve Forces Support Center 3423 N. Martin Luther King Jr. Boulevard Lansing, Michigan 48906-2934

Subject: Pre-Renovation Limited Asbestos and Lead-Containing Paint Survey Waterford Armory 2650 Watkins Lake Road Waterford, MI 48328

Dear Mr. Cole:

Atlas is pleased to present this report detailing the findings of the pre-renovation limited asbestos and lead-containing paint survey performed at the above referenced site. The purpose of this sampling was to identify and collect samples of suspect asbestos containing materials (ACMs) and lead-containing paint (LCP) prior to demolition activities.

The pre-demolition asbestos and limited lead-containing paint sampling was conducted from May 27 through June 3, 2025, by Industrial Hygienist, Ms. Rachel Kasnow, State of Michigan certified asbestos inspector. The sampling was conducted in accordance with sampling criteria specified in the Occupational Safety and Health Administration’s (OSHA) Asbestos Construction Industry Standard (29 CFR 1926.1101), and the Asbestos Hazard and Emergency Response Act of 1987

(AHERA).

If you have any questions, please call us at 248.669.5140.

Respectfully submitted, Rachel Kasnow Kandy Rauser State of Michigan Asbestos Inspector Project Manager Atlas Technical Consultants LLC Atlas Technical Consultants LLC

Page | i

CONTENTS

EXECUTIVE SUMMARY

1. INTRODUCTION

1.1 Purpose

1.2 Pre-Renovation Asbestos Survey

2. GENERAL SITE CONDITIONS

2.1 General Property and Building Information

2.2 Exterior Finish Descriptions

2.3 Interior Building Descriptions

3. PRE-RENOVATION ASBESTOS SURVEY

3.1 Homogeneous Areas

3.2 Hazard Assessment Factors

3.3 Laboratory Analytical Methodology

3.4 Sampling Results

4. LEAD-CONTAINING PAINT SAMPLING

5. LEAD DUST WIPE SAMPLING

6. CONCLUSIONS AND RECOMMENDATIONS

6.1 Asbestos Containing Materials

6.2 Lead-Containing Paint

6.3 Lead Dust Wipe Sampling

7. ASSUMPTIONS AND LIMITATIONS

TABLES

Table 3-1 ACM Sampling Results

Table 4-1 Lead-Containing Paint Sampling Results

Table 5-1 Lead Dust Wipe Sampling Results………………………………………………………….7

APPENDICES

Appendix A Sample Location Drawing Appendix B Photo Log Appendix C Asbestos Laboratory Report Appendix D Lead-Containing Paint Laboratory Report Appendix E Lead Dust Wipe Laboratory Report

SOM

Waterford Armory

Pre-Renovation Limited Asbestos & Lead-Containing Paint Survey June 19, 2025

Page | 2

EXECUTIVE SUMMARY

Atlas representative Ms. Rachel Kasnow, completed the pre-renovation limited asbestos and lead-containing paint survey of the Waterford Armory, at 2650 Watkins Lake Road, in Waterford, Michigan, May 27 through June 3, 2025.

Three hundred and twelve (312) asbestos bulk samples, taken from one hundred and four (104) homogenous areas, were collected and submitted for analysis by Polarized Light Microscopy

(PLM). Of the 312 samples submitted, three hundred and fifty-one (351) sample layers were analysed, and five (5) samples were analysed by point count. The results of laboratory testing indicated that five (5) of the suspect materials contained greater than 1 percent asbestos and four

(4) of the suspect materials were assumed to contain asbestos.

Eleven (11) representative samples of paint, taken from interior and exterior areas of the building, were collected and submitted for analysis by Flame AAS. The results of laboratory testing of the paint chip samples indicated that all eleven (11) samples contained levels of lead greater than the laboratory reporting limits.

Six (6) representative lead dust wipe samples, taken from surfaces within and directly connected to the shooting range area, were collected and submitted for analysis. The results of laboratory testing of the dust wipe samples indicated that two (2) samples contained levels of lead greater than the allowable USEPA HUD standards for floors.

If any additional materials are discovered during renovation/demolition activities, such materials must be assumed to contain asbestos until sampling and analysis proves otherwise.

Page | 3

1. INTRODUCTION

1.1 Purpose

The purpose of this project was to conduct a pre-renovation limited asbestos and lead-containing paint survey of the Waterford Armory located at 2650 Watkins Lake Road, in Waterford, Michigan.

1.2 Pre-Renovation Asbestos Survey

The scope of the pre-renovation asbestos survey included the following:

• Review of existing asbestos reports for the building, if available;

• Survey of the property building(s);

• Identification of accessible suspect asbestos-containing materials (ACMs);

• Collection and analysis of bulk samples of suspect friable and non-friable materials.

2. GENERAL SITE CONDITIONS

2.1 General Property and Building Information

General property and building information is presented in the following table:

General Property and Building Information

Date of Inspection: May 27 through June 3, 2025

Inspectors Rachel Kasnow, Inspector # A61030

Property Address: 2650 Watkins Lake Road, Waterford, Michigan 48328

Property Owner Michigan Department of Military & Veterans Affairs

Building Description: Waterford Armory

2.2 Exterior Finish Descriptions

The exterior of the buildings included block and masonry with a flat roof.

2.3 Interior Building Descriptions

The interior finishes of the building included concrete masonry unit (CMU) block walls, wallboard, ceiling tiles/panels, and tiled walls and floors.

3. PRE-RENOVATION ASBESTOS SURVEY

Atlas representative Ms. Rachel Kasnow conducted the pre-renovation asbestos inspection of the property building from May 27 through June 3, 2025. Ms. Kasnow is a State of Michigan Certified

Asbestos Inspector’s (Certification No. A61030). The building was visually inspected for the presence of building materials that are suspected to contain asbestos. Bulk samples of suspect

ACMs were collected and placed into individual containers for transport to a National Voluntary

Lab Accreditation Program (NVLAP)-accredited laboratory for analysis. Materials typically known as non-asbestos items (i.e. fibrous glass, foam rubber, wood, etc.) were not sampled. The asbestos inspection consisted of the following three basic procedures:

Page | 4

> Conducting a visual inspection of the structures;

> Identifying homogeneous areas (HAs) of suspect surfacing, thermal system insulation, and miscellaneous materials; and

> Sampling accessible, friable and non-friable suspect materials.

3.1 Homogeneous Areas

Prior to collecting any samples, homogenous areas (HAs) were identified. A homogeneous sampling area can be described as one or more areas of material that are similar in appearance and texture and that have the same apparent installation date, appearance and function. Actual number of samples collected from each homogeneous sampling area may vary, based on the type of material and professional opinion of the inspector.

3.2 Hazard Assessment Factors

From the list of suspect homogeneous areas, a physical assessment was performed for each material on the list. A physical assessment includes evaluating the condition, assessing the potential for disturbance, and determining the friability of each material. By definition, "friable" materials are those that can be crumbled or reduced to powder by hand pressure when dry. Each material identified was further classified into one of three categories: surfacing materials, thermal systems insulation (TSI) and miscellaneous materials. Each of the three categories have specific sampling requirements, outlined below.

• Surfacing Materials: Refers to spray-applied or troweled surfaces such as plaster ceilings and walls, fireproofing, textured paints, textured plasters, and spray-applied acoustical surfaces.

• Thermal System Insulation: Refers to insulation used to inhibit heat gain or loss on pipes, boilers, tanks, ducts, and various other building components.

• Miscellaneous Materials: Refers to friable and non-friable products and materials that do not fit in any of the above two categories such as resilient floor covering, baseboards, mastics, adhesives, roofing material, caulking, glazing, and siding. This category also contains wallboard and ceiling tile.

All materials were assessed related to their condition in one of the three categories: good (intact), fair (damaged) or poor (significantly damaged) per Title 40 Code of Federal Regulations Part 763.

Material with localized, significant damage was also assessed as poor.

3.3 Laboratory Analytical Methodology

Bulk samples were analyzed by Environmental Testing Laboratories, Inc. (ETL) using polarized-light microscopy (PLM) and dispersion staining (Method Reference: 40 CFR Part 763, Volume 47, No.

103, May 27, 1982, pg. 23376). This laboratory participates in the National Voluntary Laboratory

Accreditation Program (NVLAP #201028-0), a quality assurance program for PLM analysis, and is accredited by the National Institute of Standards and Technology (NIST) as well as accreditation requirements under 15 CFR Part 25.

Positive sample results are reported in percent asbestos by volume of the sample and the type of asbestos material within the sample. Other common non-asbestos components may also be noted on the analytical reports.

Page | 5

3.4 Sampling Results

Bulk samples were collected from the site building and analyzed by polarized light microscopy

(PLM), EPA Method 600/R-93/116. A sample location drawing can be found in Appendix A. A photo log depicting suspect ACMs can be found in Appendix B. Copies of the laboratory analytical report and corresponding chain-of-custody forms are included in Appendix C.

The following table provides a summary of accessible suspect and confirmed ACMs from the Site buildings:

Table 3-1 ACM Sampling Results

Sample ID/Material

Location of Materials Material Estimated Quantity

Asbestos Content

Main Building

1-CC-A,B,C Throughout Poured Concrete Floors 21,061 SF None Detected

2-EJ-A,B,C

Room 100, 101, 103, 104, 117, and 119 Concrete Floor Expansion

Joint 446 SF None Detected

3-EJ-A,B,C Room 100, 101, and 103 Concrete Floor, Soft, Grey

Expansion Joint 345 SF None Detected

4-CMU-A,B,C Throughout CMU Block Wall Mortar 23,630 SF None Detected

5-EJ-A,B,C

Main and South Entrance, South Main Corridor, West

Vestibule and Corridor, Central Main Corridor, Lobby, North Main Corridor, and Rooms 100, 101, 103, 104, 117, and

CMU Block Wall Expansion Joint

845 SF None Detected

6-IC-A,B,C Rooms 100 and 117 Interior Red Fire Stop Caulk 11 LF None Detected

7-IC-A,B,C

Rooms 100, 113, 114, and

Interior Dark Grey Building

Caulk 140 LF None Detected

8-PI-A,B,C Throughout Fiberglass Pipe Insulation 782 LF None Detected

9-SM-

A,B,C,D,E

Rooms 100 and 137 Yellow Painted White, Fluffy

Spray-on Insulation 3,825 SF None Detected

10-Not Sampled

Room 100 Fiberglass HVAC Duct

Insulation

60 SF ASSUMED

11-IC-A,B,C Rooms 100, 119, and 137 Interior Pinkish Brown Pipe

Penetration Mud 3 SF None Detected

12-Not Sampled

Room 100 Black Metal Duct Seam

Sealant of HVAC

125 LF ASSUMED

13-IC-A,B,C Room 101 Interior Tan Brittle Door

Caulk 15 LF None Detected

14-IC-A,B,C Throughout Interior Off-White Door

Caulk 490 LF None Detected

15-PB-A,B,C Room 101 Pressboard Penetration

Hole Filler 1 SF None Detected

16-PI-A,B,C Room 101 Packing Insulation 1 SF None Detected

17-CC-A,B,C

Rooms 101, 102, 106, 107, 133, and 137 Concrete Ceiling 2,757 SF None Detected

Page | 6

Sample ID/Material

Location of Materials Material Estimated Quantity

Asbestos Content

18-RT-A,B,C Room 101 Black Roof Tar 30 SF Point Count:

1.5% Chrysotile

19-CT-A,B,C Rooms 102, 106, and 107 6" x 6" Tan Ceramic Floor

Tile and Grout 728 SF None Detected

20-CTG-

A,B,C

Rooms 102, 106, and 107 6" x 16" Grey Block Wall

Grout 1,750 SF None Detected

21-IC-A,B,C Throughout Interior Tan/Gold Building

Caulk 655 LF None Detected

22-IC-A,B,C Throughout Interior White Building

Caulk 277 LF None Detected

23-IC-A,B,C Room 103 Interior Grey, Brittle Caulk 3 LF None Detected

24-IC-A,B,C Room 104 Interior Brittle Multi-Layer

Sink Caulk 5 LF None Detected

25-CP-A,B,C

Room 104 and

North Vestibule & Associated Corridor

2' x 4' Ceiling Panel with Pinholes and Long Gouges

208 SF None Detected

26-HS-A,B,C Rooms 104 and 105 Heat Shield 2 SF None Detected

27-CT-A,B,C Rooms 104, 134, and 139 4” Beige Speckled Cove Base Ceramic Floor Tile and Grout 149 SF None Detected

28-CT-A,B,C Rooms 104, 134, and 139 1" x 1" Beige Ceramic Floor

Tile and Grout 445 SF None Detected

29-IC-A,B,C

Rooms 104, 105, 107, 134, 139, and 140 Interior White Plumbing

Fixture Caulk 101 LF None Detected

30-CT-A,B,C Rooms 105 and 140 4" Pink Cove Base Ceramic

Tile and Grout 235 SF None Detected

31-CTG-

A,B,C

Room 105 and 140 1" x 1" Off-White Ceramic

Tile Floor Grout 5 SF None Detected

32-PA-A,B,C Room 105 Paper and Adhesive Under

Plumbing Caulk 15 LF None Detected

33-IC-A,B,C Room 106 Interior Light Grey Multi-layer Caulk 110 LF None Detected

34-SU-A,B,C Room 106 and 107 Grey Sink Undercoating 14,452 SF None Detected

35-CP-A,B,C Throughout 2' x 4' Ceiling Panel with

Pinholes and Small Gouges 10,210 SF None Detected

36-WBS-

A,B,C

Throughout Wallboard System 2,730 SF None Detected

37-BM-A,B,C

West Vestibule & Associated Corridor, Central Main Corridor, Lobby, North Main

Corridor, North Vestibule &

Associated Corridor, and Rooms 147, 148, & 153

Interior Multi-Color Brick and Mortar

1,003 SF None Detected

Page | 7

ID/Material

Location of Materials Material Estimated Quantity

Asbestos Content

38-CB-A,B,C

Main Entrance (South Vestibule), South Main

Corridor, West Vestibule &

Associated Corridor, Central Main Corridor, Lobby, North Main Corridor, North Vestibule & Associated Corridor, and Rooms 109, 110, & 136

4" Grey Cove base and Adhesive

5,183 SF None Detected

39-FT-A,B,C

Main Entrance (South Vestibule), South Main

Corridor, West Vestibule &

Associated Corridor, Central Main Corridor, Lobby, North Main Corridor, North Vestibule & Associated Corridor, and Rooms 109, 110, & 136

12"x 12" Light Grey/Blue Mottled with White and Grey

Streaks, Floor Tile and Mastic

60 SF None Detected

40-FT-A,B,C

Main Entrance (South Vestibule), South Main

Corridor, West Vestibule &

Associated Corridor, Central Main Corridor, and

Rooms 109 & 110

12" x 12" Blue/Grey Mottled with White Streaks, Floor

Tile and Mastic 102 SF None Detected

41-FT-A,B,C

Lobby, North Main Corridor, North Vestibule & Associated Corridor, and

Room 109

12" x 12" Blue Mottled Floor Tile and Mastic

15 SF None Detected

42-FT-A,B,C Room 109

12" x 12" Light Grey Mottled with White and Grey

Streaks, Floor Tile and Mastic

940 SF None Detected

43-CC-A,B,C Rooms 110 and 111 Nailed in Cement Boards 1,555 SF None Detected

44-CB-A,B,C Throughout 4" Black Cove Base and

Adhesive 7,524 SF None Detected

45-CM-A,B,C Throughout Yellow Carpet Mastic 750 SF None Detected

46-CC-A,B,C Rooms 115, 116, and 137 Concrete Wall 290 SF None Detected

47-IC-A,B,C Throughout Interior Light Grey Building

Caulk 8,644 LF None Detected

48-SM-A,B,C Throughout White Fluffy Spray-on

Insulation 413 SF None Detected

49-DI-A,B,C Throughout Silver Foil Wrapped Duct

Insulation 150 SF None Detected

Page | 8

ID/Material

Location of Materials Material Estimated Quantity

Asbestos Content

50-DI-A,B,C Throughout Black Plastic Wrapped Duct

Insulation 210 SF None Detected

51-IC-A,B,C Throughout Interior White Multi-Layer

Window Caulk 195 LF None Detected

52-IC-A,B,C Throughout Interior Black Window Caulk 200 LF None Detected

53-SW-A,B,C Room 124 Styrofoam Wallboard

Insulation 75 SF None Detected

54-AD-A,B,C Rooms 125 and 126 Accordion Dividing Wall 250 SF None Detected

55-IC-A,B,C

Main Entrance (South Vestibule), South Main

Corridor, West Vestibule &

Associated Corridor, Central Main Corridor, North Vestibule & Associated Corridor, and Rooms 147, 148, and 152

Interior Black Window Caulk Associated with Windows in

Door Frames 80 LF None Detected

56-CT-A,B,C Room 139 4" x 4" Beige Ceramic Shower Tile and Grout

10 SF None Detected

57-CT-A,B,C Room 140 4" x 4" Pink Ceramic

Shower Tile and Grout 60 SF None Detected

58-FT-A,B,C

West Vestibule &

Associated Corridor and Central Main Corridor

12" x 12" Light Blue with Dark Grey Streaks Floor

Tile and Mastic 160 SF None Detected

59-CB-A,B,C

Lobby and North Main

Corridor 4" Blue Cove Base and

Adhesive 10 SF None Detected

60-Not Sampled

Main Entrance (South Vestibule) & South Main

Corridor

6" x 6" Orange Ceramic Tile

1 SF ASSUMED

61-IC-A,B-C

Main Entrance (South

Vestibule) & South Main Corridor

Interior, Orange, Door Window Caulk

10 LF None Detected

62-PF-A,B,C Room 117 Mudded Fittings Associated with Fiberglass Straight Pipe Insulation

1 Fitting None Detected

63-CM-A,B,C Room 117 Chimney Brick and Mortar 60 SF None Detected

64-WP-A,B,C Room 117 Black Weatherproofing 12 SF None Detected

65-SM-A,B,C Room 119 Light Green Painted Spray-

On Insulation 750 SF None Detected

66-IC-A,B,C Room 117 Interior Brown Firestop

Caulk 6 SF None Detected

67-EC-A,B,C Main Building Exterior Exterior Light Grey Cement

Sidewalk Caulk 150 LF None Detected

68-EC-A,B,C Main Building Exterior Exterior Black Building

Caulk

150 LF

Point Count:

1.25%

Chrysotile

69-EC-A,B,C Main Building Exterior Exterior Medium Grey

Metal Siding Caulk

5 LF

Point Count:

1.5% Chrysotile

Page | 9

ID/Material

Location of Materials Material Estimated Quantity

Asbestos Content

70-EC-A,B,C Main Building Exterior Exterior Red Fire-Stop

Caulk 1 SF None Detected

71-EC-A,B,C Main Building Exterior Exterior Residual Grey Door

Caulk 90 LF None Detected

72-EC-A,B,C Main Building Exterior Exterior Black Window

Caulk

300 LF

Point Count:

1.25%

Chrysotile

73-EC-A,B,C Main Building Exterior Exterior Black Door Caulk 180 LF None Detected

74-CC-A,B,C Main Building Exterior Exterior Cement

Windowsills 85 SF None Detected

75-BM-A,B,C Main Building Exterior Exterior Brick and Mortar 15,000 DG None Detected

76-EC-A,B,C Main Building Exterior Exterior Brown Pipe Penetration Caulk

3 SF None Detected

77-EC-A,B,C Main Building Exterior Exterior White Door Caulk 30 LF None Detected

78-EC-A,B,C Main Building Exterior Exterior Dark Grey Cement

Caulk 40 LF None Detected

79-EC-A,B,C Main Building Exterior Exterior White Building

Caulk 5 LF None Detected

104-RM-

A,B,C

Main Building Roof Main Building Roofing

Material 27,000 SF None Detected

Out Building

80-CC-A,B,C Throughout Poured Concrete Floor 15,625 SF None Detected

81-EJ-A,B,C

Throughout Offices, Open

Garage Space and Loft Area

Concrete Floor Expansion Joint

1,590 LF None Detected

82-CMU-

A,B,C

Throughout CMU Block Wall 9,084 SF None Detected

83-EJ-A,B,C

Throughout Offices, Open

Garage Space and Loft Area

CMU Block Wall Expansion Joint

790 LF None Detected

84-SM-A,B,C

Throughout Offices, Open

Garage Space and Loft Area

Pink Painted Spray-On Insulation

15,625 SF None Detected

85-IC-A,B,C Throughout Interior Grey Door Caulk 135 LF None Detected

86-IC-A,B,C North and South Office White Multi-layer Building

Caulk 60 LF None Detected

87-BM-A,B,C

Throughout Offices, Open

Garage Space and Loft Area

Brick and Mortar 2,320 SF None Detected

88-IC-A,B,C South Office Black Interior Window

Interior Caulk 20 LF None Detected

89-IC-A,B,C South Office Interior Black Window Caulk 15 LF None Detected

90-PI-A,B,C

Open Garage Space, Loft Area, and Storage Area

Fiberglass Straight Pipe Insulation

210 LF None Detected

91-WBS-

A,B,C

Open Garage Space and Loft Area

Wallboard System 2,600 SF None Detected

Page | 10

ID/Material

Location of Materials Material Estimated Quantity

Asbestos Content

92-FT-A,B,C Restroom 12" x 12" Blue/Grey Mottled

Floor Tile and Mastic 60 SF None Detected

93-CB-A,B,C Restroom 4" Blue Cove Base and

Adhesive 32 LF None Detected

94-HS-A,B,C Restroom Heat Shield 1 SF None Detected

95-IC-A,B,C Restroom Interior White Plumbing

Caulk 10 LF None Detected

96-Not Sampled

Restroom and Storage Room

Concrete Ceiling 93 SF ASSUMED

97-WG-A,B,C

Open Garage Space and

Loft Area Interior Second Floor

Window Glaze

260 LF

Point Count:

1.75%

Chrysotile

98-DI-A,B,C

Open Garage Space and

Loft Area Brown Paper Roof Drain

Insulation 5 SF None Detected

99-EC-A,B,C Exterior Exterior Grey Cement Caulk 150 LF None Detected

100-BM-

A,B,C

Exterior Exterior Brick and Mortar 10,000 SF None Detected

101-EC-

A,B,C

Exterior Exterior Black Window

Caulk 15 LF None Detected

102-EC-

A,B,C

Exterior Exterior Multi-layer Door

Caulk 75 LF None Detected

103-RT-

A,B,C

Roof Exterior Roof Tar 15,635 SF None Detected

EA=Exterior Area FS Functional Space NA=Not Applicable ND= None Detected

In the event additional suspect material is discovered during renovation activities, this material should be treated as presumed asbestos-containing material (PACM) in accordance with regulations 29 CFR 1926.1101 and 1910.1001 and other applicable state and local regulations and either sampled to confirm or nullify asbestos content or be treated as ACM and handled accordingly.

Page | 11

4. LEAD-CONTAINING PAINT SAMPLING

Atlas representative Ms. Rachel Kasnow conducted the lead-containing paint (LCP) sampling of the property building from May 27 through June 3, 2025. The sampling included physical sampling of paint coatings that were deemed representative of the predominant paint coatings observed.

Eleven (11) paint chip samples were collected and submitted to Accurate Analytical Testing

Laboratory, 30105 Beverly Road, Romulus, Michigan for lead analysis. Bulk samples were analyzed using the Environmental Protection Agency's Test Method SW 846-7420 and 3050B using Flame AAS to determine lead concentration in percent (%) by weight. Copies of the laboratory analytical report and corresponding chain-of-custody forms are included in Appendix

D.

The following table provides a summary of the LCP sampling:

Table 4-1 Lead-Containing Paint Sampling Results

Sample ID Sample Location Color Lead

Content

Reporting Limit

1-LPC Main Building Doors Gray 0.00185 0.000465

2-LPC Main Building Interior Walls White 0.00997 0.00112

3-LPC Main Building CMU Block Off-White 0.00296 0.00197

4-LPC Main Building CMU Block Yellow 0.0444 0.000820

5-LPC Main Building Cement Green 0.0122 0.00309

6-LPC Main Building Interior Walls White 0.00240 0.000482

7-LPC Outbuilding Metal White 0.482 0.00160

8-LPC Outbuilding Block Red 0.00569 0.00205

9-LPC Outbuilding Interior Walls Pink 0.00266 0.000624

10-LPC Outbuilding CMU Block Pink 0.00266 0.000624

11-LPC Outbuilding Metal Pipes Pink 0.0381 0.00118

Page | 12

5. LEAD DUST WIPE SAMPLING

Lead dust wipe samples were taken by Atlas representative Ms. Linda Shah, within the shooting range area on hard surface floors. Six (6) representative lead dust wipe samples were taken from floor surfaces within and directly connected to the shooting range area and submitted for lead analysis. The results of laboratory testing of the dust wipe samples indicated that two (2) samples contained levels of lead greater than the allowable USEPA HUD standards for floors.

Copies of the laboratory analytical report and corresponding chain-of-custody forms are included in Appendix E.

The following table provides a summary of the lead dust wipe floor sampling:

Table 5-1 Lead Dust Wipe Sampling Results

Dust Wipe Results

Date Of Sampling: 06/10/2025

Sample Number

Location Surface Tested*

Lead Concentration In µg/Ft2

Exceed

USEPA

Standard?

W001 Field Blank N/A N/D N/A

W002 Room 1 Hallway Floor Hard Floor (HF) <5.00 No

W003 Room 2 Shooting Range

Floor; South Entrance Hard Floor (HF) 5.10 No

W004 Room Shooting Range

Floor: Midway Hard Floor (HF) <5.00 No

W005 Room 2 Shooting Range Floor 2/3 of Floor Length

Down Range

Hard Floor

(HF)

10.2 Yes

W006 Room 2 Shooting Range

North Entry Floor Hard Floor

(HF)

313 Yes

USEPA/HUD Standards for Lead Dust Wipes

Floors (µg/ft2 = microgram per square foot) Less than 10 µg/ft2 Windowsills (µg/ft2) Less than 100 µg/ft2 Window troughs (µg/ft2) Less than 100 µg/ft2

Exterior porch floor (µg/ft2) Less than 40 µg/ft2

Page | 13

6. CONCLUSIONS AND RECOMMENDATIONS

6.1 Asbestos Containing Materials

The results of laboratory testing during the pre-renovation asbestos survey conducted at the property indicate that the following materials were found to contain asbestos or assumed to contain asbestos:

Sample ID /Material

Location of Materials

Material Estimated Quantity

Asbestos Content

10-Not Sampled Room 100 Fiberglass HVAC Duct

Insulation

60 SF ASSUMED

12-Not Sampled Room 100 Black Metal Duct Seam

Sealant of HVAC

125 LF ASSUMED

18-RT-A,B,C Room 101 Black Roof Tar 30 SF Point Count:

1.5% Chrysotile

60-Not Sampled

Main Entrance (South Vestibule)

& South Main Corridor

6" x 6" Orange Ceramic Tile

1 SF ASSUMED

68-EC-A,B,C

Main Building

Exterior Exterior Black Building

Caulk

150 LF

Point Count:

1.25% Chrysotile

69-EC-A,B,C

Main Building

Exterior Exterior Medium Grey

Metal Siding Caulk

5 LF

Point Count:

1.5% Chrysotile

72-EC-A,B,C

Main Building

Exterior Exterior Black Window

Caulk

300 LF

Point Count:

1.25% Chrysotile

96-Not Sampled Outbuilding -

Restroom and Storage Room

Concrete Ceiling 93 SF ASSUMED

97-WG-A,B,C

Outbuilding - Open Garage Space and

Loft Area

Interior Second Floor Window Glaze

260 LF

Point Count:

1.75% Chrysotile

If any additional materials are discovered during renovation/demolition activities, such materials must be assumed to contain asbestos until sampling and analysis proves otherwise.

6.2 Lead-Containing Paint

Three (3) representative samples of paint, taken from interior and exterior areas of the building, were collected and submitted for analysis by Flame AAS. The results of laboratory testing during the limited lead-containing paint sampling conducted at the property indicate that two (2) samples contained levels of lead greater than the laboratory reporting limits.

The presence of lead-containing paint requires, under OSHA 1926.62 requirements, that the contractor performing renovation, surface preparation, and other activities that impact or potentially impact the lead- coated components, evaluate potential worker exposures to airborne lead. This evaluation can be based, for the specific activities denoted in 1926.62, on objective data obtained by the contractor on other, similar, worksites within the prior calendar year. In addition, lead-containing paint and lead-coated waste and construction debris must be evaluated and, on a case-by-case basis depending on this evaluation, quantitative analysis be performed on these waste steams to ensure compliance with EPA waste disposal regulations.

Page | 14

The presence of Lead-Containing Paint (LCP) and/or Lead-Based Paint (LBP) does not, in itself, trigger regulatory compliance actions. However, when these materials are disturbed, the requirements of OSHA (1926.1101) and EPA may become operative. Appropriate actions in terms of removal methods, emissions control, worker protection, and waste disposal should be considered by the general contractor and applicable subcontractors while completing renovation activities.

6.3 Lead Dust Wipe Sampling

Lead contaminated dust is an exposure pathway for lead poisoning. Atlas recommends areas that had lead dust levels exceeding allowable USEPA HUD standards be cleaned by a State of Michigan licensed lead abatement contractor. Engineering controls should be evaluated to determine if adjustments are needed to existing HVAC systems or additional systems need to be installed. A routine maintenance schedule including regular cleaning in the impacted areas should be implemented.

7. ASSUMPTIONS AND LIMITATIONS

The results, findings, conclusions, and recommendations expressed in the report are based only on conditions that were noted during the NESHAP inspections conducted from May 19 through

May 21, 2025 performed by Atlas. Selection of sample locations and frequency of sampling were based on EPA Guidance documents, Atlas’s observations, and the assumption that building vintage and renovation history information presented to Atlas allowed the proper designation of homogenous materials for each building.

This document does not contain the elements necessary for an Abatement Work plan, and this document does not contain, nor should it take the place of technical specifications for ACM removal.

Our professional services have been performed, our findings obtained, and our conclusions and recommendations prepared in accordance with customary principles and practices in the fields of environmental science and engineering. This statement is in lieu of other statements either expressed or implied. This report does not warrant against changes to material from future operations or conditions, nor does it warrant against operations or conditions against present

ACM material in locations not investigated.

The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users and use or re-use of this document or the findings, conclusions, or recommendations is at the risk of said user.

APPENDIX A

SAMPLE LOCATION DRAWING

Asbestos and Lead Paint Chip

Sample Location Map

Main Building (1-54)

PROJECT NUMBER: 188BS25305

DRAWN BY: Rachel Kasnow REVIEWED BY Atlas

FIGURE: 1

DATE: 6/11/2025

4 6 5 5 5 H u m b o l d t D r i v e , S u i t e 1 0 0

N o v i , M i c h i g a n 4 8 3 7 7

P h : ( 2 4 8 ) 6 6 9 - 5 1 4 0 ~ F a x : ( 2 4 8 ) 6 6 9 - 5 1 4 7

KEY

Asbestos Sample Location

Lead Paint Chip Sample Location

Positive Materials HA#

Assumed Materials HA#

State of Michigan – Waterford Armory

2650 Watkins Lake Road, Waterford, MI 48328

23-IC-A,B,C

1-CC-B

1-CC-C

39-FT-B

4-CMU-A

11-PM-A

5-EJ-A,B,C

7-IC-A

9-SM-D,E 13-IC-A,B,C

3-EJ-B

2-EJ-B

8-PI-B

2-EJ-A

9-SM-A,B,C

3-EJ-A

7-IC-C

40-FT-B

3-EJ-C

14-IC-A

40-FT-C

15-PB-A,B,C

16-PI-A,B,C

17-CC-A,B,C

18-RT-A,B,C

2-EJ-C

4-CMU-B

21-IC-B

4-CMU-C

36-WBS-A

7-IC-B

45-CM-A

8-PI-A

66-IC-A,B,C

11-PM-B

11-PM-C

46-CC-A,B,C

47-IC-B

14-IC-C

14-IC-B

24-IC-A,B,C

25-CP-A,B,C

43-CC-A,B,C

19-CT-A

22-IC-A

21-IC-A

20-CTG-A,B,C

34-SU-C

19-CT-B,C

33-IC-A,B,C

8-PI-C

30-CT-A,B,C

1-CC-A

41-FT-A,B,C

22-IC-B

22-IC-C

45-CM-B

26-HS-B

26-HS-C

29-IC-A

26-HS-A

29-IC-B

31-CTG-A,B,C

32-PA-A,B,C

27-CT-A,B,C

28-CT-A

28-CT-B,C

29-IC-C

34-SU-B

34-SU-A

35-CP-A

48-SM-A

49-DI-A

50-DI-A

35-CP-B

36-WBS-B

48-SM-B

49-DI-C

53-SW-A,B,C

35-CP-C

36-WBS-C

37-BM-A,B,C

38-CB-C

38-CB-B

39-FT-A

38-CB-A

39-FT-C

40-FT-A

42-FT-A,B,C

44-CB-A

44-CB-C

44-CB-B

45-CM-C

48-SM-E

47-IC-A

47-IC-C

48-SM-C

48-SM-D

48-SM-F

48-SM-G

49-DI-B

50-DI-B

50-DI-C

51-IC-A

52-IC-B

51-IC-C

51-IC-B

52-IC-A

52-IC-C

54-AD-A,B,C

59-CB-A,B,C

10-DI-A,B,C

12-DS-A,B,C

Asbestos and Lead Paint Chip

Sample Location Map

Main Building

PROJECT NUMBER: 188BS25305

DRAWN BY: Rachel Kasnow REVIEWED BY Atlas

FIGURE: 2

DATE: 6/11/2025

4 6 5 5 5 H u m b o l d t D r i v e , S u i t e 1 0 0

N o v i , M i c h i g a n 4 8 3 7 7

P h : ( 2 4 8 ) 6 6 9 - 5 1 4 0 ~ F a x : ( 2 4 8 ) 6 6 9 - 5 1 4 7

KEY

Asbestos Sample Location

Lead Paint Chip Sample Location

Positive Materials HA#

Assumed Materials HA#

State of Michigan – Waterford Armory

2650 Watkins Lake Road, Waterford, MI 48328

77-EC-A73-EC-A

71-EC-B

73-EC-B

73-EC-C

78-EC-B,C

62-PF-A,B,C

66-IC-A,B,C

65-SM-C

77-EC-B,C

57-CT-A,B,C

69-EC-C

61-IC-A,B,C

52-IC-C

55-IC-C

58-FT-A,B,C

55-IC-A55-IC-B

56-CT-A,B,C

59-CB-A,B,C

63-CM-A,B,C

64-WP-A,B,C

65-SM-A,B

67-EC-A

68-EC-B

67-EC-B

67-EC-C

72-EC-A

74-CC-A,B,C

75-BM-A,B,C

72-EC-B

72-EC-C

76-EC-A

68-EC-A

71-EC-A

69-EC-A,B

70-EC-A,B,C

68-EC-C

76-EC-B

79-EC-A,B,C

78-EC-A

76-EC-C

104-RM-A,B,C

1-LPC

2-LPC

3-LPC

4-LPC

5-LPC

71-EC-C

60-CT-A,B,C

State of Michigan – Waterford Armory

2650 Watkins Lake Rd, Waterford, MI

48328

Asbestos and Lead Chip Paint

Sample Location Map -

Outbuilding

PROJECT NUMBER: 188BS25305

DRAWN BY: Rachel Kasnow REVIEWED BY Atlas

FIGURE: 3

DATE: 6/11/2025

4 6 5 5 5 H u m b o l d t D r i v e , S u i t e 1 0 0

N o v i , M i c h i g a n 4 8 3 7 7

P h : ( 2 4 8 ) 6 6 9 - 5 1 4 0 ~ F a x : ( 2 4 8 ) 6 6 9 - 5 1 4 7

KEY

Asbestos Sample Location

Lead Paint Chip Sample Location

Positive Materials HA#

Assumed Materials HA#

MAP NOT TO SCALE

South Office

North Office

Storage Bathroom

Open Garage

Second Floor Open Loft Space

100-BM-A

84-SM-A

98-DI-A,B,C

103-RT-A

84-SM-D

90-PI-B

90-PI-C

103-RT-B,C

102-EC-A

100-BM-C

102-EC-C

102-EC-B

101-EC-A,B,C

100-BM-B

99-EC-A,B,C

91-WBS-C

97-WG-A

97-WG-B

83-EJ-A,B,C

97-WG-C

89-IC-B,C

94-HS-A,B,C

92-FT-A,B,C

93-CB-A,B,C

95-IC-A

95-IC-B,C

82-CMU-A,B,C

91-WBS-A,B

90-PI-A

89-IC-A

85-IC-A,B

88-IC-A,B,C

87-BM-A,B,C

86-IC-A

86-IC-B

86-IC-C

80-CC-A,B,C

85-IC-C

84-SM-B

84-SM-C

84-SM-E

81-EJ-C

81-EJ-B

81-EJ-A

8-LPC

6-LPC

11-LPC

10-LPC

9-LPC

7-LPC

96-CC-A,B,C

APPENDIX B

PHOTO LOG

State of Michigan - Waterford Armory

Photograph Log 2650 Watkins Lake Road Waterford Township, Michigan 48328

188BS25305

Photograph #1

Homogenous Material Description

HA-1: Poured Concrete Floors

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

20,531 SF

Additional Notes

Photograph #2

HA-2: Concrete Floor Expansion Joint

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

446 LF

Photograph #3

HA-3: Concrete Floor, Soft, Grey Expansion Joint

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

345 LF

Waterford Township, Michigan 48328

Photograph #4

HA-4: CMU Block Wall Mortar

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

22,250 SF

Photograph #5

HA-5: CMU Block Wall Expansion Joint

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

845 LF

Photograph #6

HA-6: Interior Red Fire Stop Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

11 SF

Waterford Township, Michigan 48328

Photograph #7

HA-7: Grey Interior Door Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

140 LF

Photograph #8

HA-8: Fiberglass Pipe Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

742 LF

Photograph #9

HA-9: Yellow Painted White, Fluffy Spray on Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

3,825 SF

Waterford Township, Michigan 48328

Photograph #10

HA-10: Fiberglass HVAC Duct Insulation

Asbestos Present (Yes/No/Assumed)

Assumed

Total Quantity Present

60 SF

Photograph #11

HA-11: Pinkish Brown Pipe Penetration Mud

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

3 SF

Photograph #12

HA-12: Black Metal Duct Seam Sealant of HVAC

Asbestos Present (Yes/No/Assumed)

Assumed

Total Quantity Present

125 LF

Waterford Township, Michigan 48328

Photograph #13

HA-13: Interior Tan Brittle Door Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

15 LF

Photograph #14

HA-14: Interior Off-White Door Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

490 LF

Photograph #15

HA-15: Pressboard Penetration Hole Filler

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1 SF

Waterford Township, Michigan 48328

Photograph #16

HA-16: Packing Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Photograph #17

HA-17: Concrete Ceiling

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

2,757 SF

Photograph #18

HA-18: Black Roof Tar

Asbestos Present (Yes/No/Assumed)

1.5% Chrysotile (point count)

Total Quantity Present

30 SF

Waterford Township, Michigan 48328

Photograph #19

HA-19: 6" x 6" Tan Ceramic Floor Tile and Grout

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

728 SF

Photograph #20

HA-20: 6" x 16" Grey Block Wall and Grout

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1,750 SF

Photograph #21

HA-21: Interior Tan/Gold Building Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

655 LF

Waterford Township, Michigan 48328

Photograph #22

HA-22: Interior White Building Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

277 LF

Photograph #23

HA-23: Interior Grey, Brittle Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

3 LF

Photograph #24

HA-24: Interior Brittle Multi-Layer Sink Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

5 LF

Waterford Township, Michigan 48328

Photograph #25

HA-25: 2' x 4' Ceiling Panel with Pinholes and Long Gouges

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

208 SF

Photograph #26

HA-26: Heat Shield

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

2 EA

Photograph #27

HA-27: 4" Beige Speckled Cove Base Ceramic Floor Tile and Grout

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

75 SF

Waterford Township, Michigan 48328

Photograph #28

HA-28: 1" x 1" Beige Ceramic Floor Tile and Grout

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

101 SF

Photograph #29

HA-29: Interior White Plumbing Fixture Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

75 SF

Photograph #30

HA-30: 4" Pink Cove Base Ceramic Tile and Grout

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

69 SF

Waterford Township, Michigan 48328

Photograph #31

HA-31: 1" x 1" Off-White Ceramic Tile Floor and Grout

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

145 SF

Photograph #32

HA-32: Paper and Adhesive Under Plumbing Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

235 SF

Photograph #33

HA-33: Interior Light Grey Multi-Layer Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Waterford Township, Michigan 48328

Photograph #34

HA-34: Grey Sink Undercoating

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

110 SF

Photograph #35

HA-35: 2' x 4' Ceiling Panel with Pinholes and Small Gouges

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

14,152 SF

Photograph #36

HA-36: Wallboard System

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

10,210 SF

Waterford Township, Michigan 48328

Photograph #37

HA-37: Multi-Color Brick and Mortar

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

2,730 SF

Photograph #38

HA-38: 4" Grey Cove Base and Adhesive

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1,003 LF

Photograph #39

HA-39: 12"x 12" Light Grey/Blue Mottled with White and Grey Streaks, Floor Tile and Mastic

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

5,183 SF

Waterford Township, Michigan 48328

Photograph #40

HA-40: 12" x 12" Blue/Grey Mottled with White Streaks, Floor Tile and Mastic

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Photograph #41

HA-41: 12" x 12"Blue Mottled Floor Tile and Mastic

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

102 SF

Photograph #42

HA-42: 12" x 12" Light Grey Mottled with White and Grey Streaks, Floor Tile and Mastic

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

15 SF

Waterford Township, Michigan 48328

Photograph #43

HA-43: Nailed in Cement Boards

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

940 SF

Photograph #44

HA-44: 4" Black Cove Base and Adhesive

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1,555 SF

Photograph #45

HA-45: Yellow Carpet Mastic

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

7,524 SF

Waterford Township, Michigan 48328

Photograph #46

HA-46: Concrete Wall

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

750 SF

Photograph #47

HA-47: Interior Light Grey Building Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

290 LF

Photograph #48

HA-48: White Fluffy Spray-on Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

8,344 SF

Waterford Township, Michigan 48328

Photograph #49

HA-49: Silver Foil Wrapped Duct Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

393 SF

Photograph #50

HA-50: Black Plastic Wrapped Duct Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

95 SF

Photograph #51

HA-51: Interior White Multi-Layer Window Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

210 LF

Waterford Township, Michigan 48328

Photograph #52

HA-52: Interior Black Window Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

195 LF

Photograph #53

HA-53: Styrofoam Wallboard Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

300 SF

Photograph #54

HA-54: Accordion Dividing Wall

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

200 SF

Waterford Township, Michigan 48328

Photograph #55

HA-55: Interior Black Window Caulk Associated with Windows in Door Frames

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

75 LF

Photograph #56

HA-56: 4" x 4" Beige Ceramic Shower Tile

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

250 SF

Photograph #57

HA-57: 4" x 4" Pink Ceramic Shower Tile

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

80 SF

Waterford Township, Michigan 48328

Photograph #58

HA-58: 12" x 12" Light Blue with Dark Grey Streaks Floor Tile and Mastic

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

10 SF

Photograph #59

HA-59: 4" Blue Cove Base and Adhesive

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

60 LF

Photograph #60

HA-60: 6" x 6" Orange Ceramic Tile

Asbestos Present (Yes/No/Assumed)

Assumed

Total Quantity Present

160 SF

Waterford Township, Michigan 48328

Photograph #61

HA-61: Interior, Orange, Door Window Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

10 LF

Photograph #62

HA-62: Mudded Fittings Associated with Fiberglass Straight Pipe Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1 EA

Photograph #63

HA-63: Chimney Brick and Mortar

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Waterford Township, Michigan 48328

Photograph #64

HA-64: Black Weatherproofing

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

12 SF

Photograph #65

HA-65: Green Spray-On Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

750 SF

Photograph #66

HA-66: Interior Brown Firestop Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

6 SF

Waterford Township, Michigan 48328

Photograph #67

HA-67: Exterior Light Grey Cement Sidewalk Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

150 LF

Photograph #68

HA-68: Exterior Black Building Caulk

Asbestos Present (Yes/No/Assumed)

Point Count: 1.25% Chrysotile

Total Quantity Present

Photograph #69

HA-69: Exterior Medium Grey Metal Siding Caulk

Asbestos Present (Yes/No/Assumed)

Point Count: 1.5% Chrysotile

Total Quantity Present

Waterford Township, Michigan 48328

Photograph #70

HA-70: Exterior Red Fire-Stop Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Photograph #71

HA-71: Exterior Residual Grey Door Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

90 LF

Photograph #72

HA-72: Exterior Black Window Caulk

Asbestos Present (Yes/No/Assumed)

Point Count: 1.25% Chrysotile

Total Quantity Present

300 LF

Waterford Township, Michigan 48328

Photograph #73

HA-73: Exterior Black Door Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

180 LF

Photograph #74

HA-74: Exterior Cement Windowsills

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

85 SF

Photograph #75

HA-75: Exterior Brick and Mortar

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

15,000 SF

Waterford Township, Michigan 48328

Photograph #76

HA-76: Exterior Brown Pipe Penetration Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

3 SF

Photograph #77

HA-77: Exterior White Door Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

30 LF

Photograph #78

HA-78: Exterior Dark Grey Cement Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

40 LF

Waterford Township, Michigan 48328

Photograph #79

HA-79: Exterior White Building Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Photograph #80

HA-80: Outbuilding - Poured Concrete Floor

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

15,625 SF

Photograph #81

HA-81: Outbuilding - Concrete Floor Expansion Joint

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1,590 LF

Waterford Township, Michigan 48328

Photograph #82

HA-82: Outbuilding - CMU Block Wall

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

10,000 SF

Photograph #83

HA-83: Outbuilding - CMU Block Wall Expansion Joint

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

790 LF

Photograph #84

HA-84: Outbuilding - Pink Spray-On Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

15,625 SF

Waterford Township, Michigan 48328

Photograph #85

HA-85: Outbuilding - Interior Grey Door Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

130 LF

Photograph #86

HA-86: Outbuilding - White Multi-layer Building Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

60 LF

Photograph #87

HA-87: Outbuilding - Brick and Mortar

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

2,320 SF

Waterford Township, Michigan 48328

Photograph #88

HA-88: Outbuilding - Black Interior Window Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

20 LF

Photograph #89

HA-89: Outbuilding - Interior Black Window Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Photograph #90

HA-90: Outbuilding - Fiberglass Straight Pipe Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

210 LF

Waterford Township, Michigan 48328

Photograph #91

HA-91: Outbuilding - Wallboard System

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

2,600 SF

Photograph #92

HA-92: Outbuilding - 12" x 12" Blue/Grey Mottled Floor Tile and Mastic

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Photograph #93

HA-93: Outbuilding - 4" Blue Cove Base and Adhesive

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

32 LF

Waterford Township, Michigan 48328

Photograph #94

HA-94: Outbuilding – Heat Shield

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1 EA

Photograph #95

HA-95: Outbuilding - Interior White Plumbing Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

10 LF

Photograph #96

HA-96: Outbuilding – Concrete Ceiling

Asbestos Present (Yes/No/Assumed)

Assumed

Total Quantity Present

138 SF

Waterford Township, Michigan 48328

Photograph #97

HA-97: Outbuilding - Interior Second Floor Window Glaze

Asbestos Present (Yes/No/Assumed)

Point Count: 1.75% Chrysotile

Total Quantity Present

260 LF

Photograph #98

HA-98: Outbuilding - Brown Paper Roof Drain Insulation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

5 SF

Photograph #99

HA-99: Outbuilding - Exterior Grey Cement Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Waterford Township, Michigan 48328

Photograph #100

HA-100: Outbuilding - Exterior Brick and Mortar

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

10,000 SF

Photograph #101

HA-101: Outbuilding - Exterior Black Window Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

Photograph #102

HA-102: Outbuilding - Exterior Multi-layer Door Caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

75 LF

Waterford Township, Michigan 48328

Photograph #103

HA-103: Outbuilding - Exterior Roof Tar

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

15,635 SF

Photograph #104

HA-104: Roofing Material

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

27,000 SF

Waterford Township, Michigan 48328

Photograph #1

HA-1: Grey Paint on Metal

Asbestos Present (Yes/No/Assumed)

Total Quantity Present

Photograph #2

LPC-2: White Paint on Drywall

Photograph #3

LPC-3: Off-White Paint on CMU Block

Waterford Township, Michigan 48328

Photograph #4

LPC-4: Yellow Paint on CMU Block

Photograph #5

LPC-5: Green Paint on Cement

Photograph #6

LPC-6: White Paint on Drywall

Waterford Township, Michigan 48328

Photograph #7

LPC-7: White Paint on Metal

Photograph #8

LPC-8: Red Paint on CMU Block

Photograph #9

LPC-9: Pink Paint on Drywall

Waterford Township, Michigan 48328

Photograph #10

LPC-10: Pink Paint on CMU Block

Photograph #11

LPC-11: Pink Paint on Metal

APPENDIX C

ASBESTOS LABORATORY REPORT

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive Romulus, Michigan 48174

(734) 955-6600

Fax: (734) 955-6604

To:

Attention:

Atlas - Novi

46555 Humboldt Dr. Suite 100

Novi, Michigan 48377

Project Location:

State of Michigan

Waterford Armory

Client Project: 188BS25305

279409ETL Job:

Jennifer Fashbaugh

Lab Sample Number Client Sample Number Sample Type Completed

1795753 Asbestos1-CC-A 06/10/2025

1795754 Asbestos1-CC-B 06/10/2025

1795755 Asbestos1-CC-C 06/10/2025

1795756 Asbestos2-EJ-A 06/10/2025

1795757 Asbestos2-EJ-B 06/10/2025

1795758 Asbestos2-EJ-C 06/10/2025

1795759 Asbestos3-EJ-A 06/10/2025

1795760 Asbestos3-EJ-B 06/10/2025

1795761 Asbestos3-EJ-C 06/10/2025

1795762 Asbestos4-CMU-A 06/10/2025

1795763 Asbestos4-CMU-B 06/10/2025

1795764 Asbestos4-CMU-C 06/10/2025

1795765 Asbestos5-EJ-A 06/10/2025

1795766 Asbestos5-EJ-B 06/10/2025

1795767 Asbestos5-EJ-C 06/10/2025

1795768 Asbestos6-IC-A 06/10/2025

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Lab Sample Number Client Sample Number Sample Type Completed

1795769 Asbestos6-IC-B 06/10/2025

1795770 Asbestos6-IC-C 06/10/2025

1795771 Asbestos7-IC-A 06/10/2025

1795772 Asbestos7-IC-B 06/10/2025

1795773 Asbestos7-IC-C 06/10/2025

1795774 Asbestos8-PI-A 06/10/2025

1795775 Asbestos8-PI-B 06/10/2025

1795776 Asbestos8-PI-C 06/10/2025

1795777 Asbestos9-SM-A 06/10/2025

1795778 Asbestos9-SM-B 06/10/2025

1795779 Asbestos9-SM-C 06/10/2025

1795780 Asbestos9-SM-D 06/10/2025

1795781 Asbestos9-SM-E 06/10/2025

1795782 Asbestos11-PM-A 06/10/2025

1795783 Asbestos11-PM-B 06/10/2025

1795784 Asbestos11-PM-C 06/10/2025

1795785 Asbestos13-IC-A 06/10/2025

1795786 Asbestos13-IC-B 06/10/2025

1795787 Asbestos13-IC-C 06/10/2025

1795788 Asbestos14-IC-A 06/10/2025

1795789 Asbestos14-IC-B 06/10/2025

1795790 Asbestos14-IC-C 06/10/2025

1795791 Asbestos15-PB-A 06/10/2025

1795792 Asbestos15-PB-B 06/10/2025

1795793 Asbestos15-PB-C 06/10/2025

1795794 Asbestos16-PI-A 06/10/2025

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this

1795795 Asbestos16-PI-B 06/10/2025

1795796 Asbestos16-PI-C 06/10/2025

1795797 Asbestos17-CC-A 06/10/2025

1795798 Asbestos17-CC-B 06/10/2025

1795799 Asbestos17-CC-C 06/10/2025

1795800 Asbestos18-RT-A 06/10/2025

1795801 Asbestos18-RT-B 06/10/2025

1795802 Asbestos18-RT-C 06/10/2025

1795803 Asbestos19-CT-A 06/10/2025

1795804…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .