This document is Addendum One to RFB #2524 issued by Kenosha County on October 28, 2025, for Communication Building Roof Replacement. The addendum addresses three questions submitted during the bidding process regarding project specifications and requirements. Contractors are responsible for obtaining roof dimensions and heights independently; site visits to take measurements can be arranged by contacting Rhett Surman at (920) 309-2179.
The estimated budget for the project is $30,000. A key specification change was clarified in response to a bidder question regarding insulation thickness. The original specification of 2 layers of 2" insulation with 1/4" tapered PolyISO was modified to increase insulation thickness to 3 layers of 2" PolyISO with 1/4" tapered PolyISO to address potential conflicts with existing roof height and structural elements such as metal fascia and scuppers. This change eliminates the need for contractors to decide between removing and rebuilding the metal edge or cutting wall sections.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RFB #2524 Addendum One Page 1 of 1
Yes.
Questions & Answers:
Q1. What is the estimated budget?
A. The estimated budget is $30,000.
Q2. It states that the new insulation is 2 layers of 2" with 1/4" Tapered. If existing insulation is thicker than specified, new roof insulation would be lower than existing roof line. In this case the entire metal edge would need to be removed and rebuilt with a wood nailer to proper height of new insulation or cut part of wall out for the scuppers to be installed. If metal fascia is to stay added insulation may be needed to achieve the same height as existing. Would you rather add additional insulation or remove all metal edge/ fascia and wood nailer to install new for specified insulation height?
A. Increase Insulation thickness to 3 - 2" Layers of PolyISO with 1/4"
Tapered PolyISO.
Q3. Can you provide a scale on the plans for the roof replacement?
A. Measurements are the responsibility of the bidding contractor, to obtain roof dimensions and heights. If any contractor needs to set up a time to come on site and take measurements, please reach out to Rhett Surman at (920) 309-2179.