250822_CCGA_StudentActivityCenter_BidSet_Draw.pdf
PDF 18 MB Posted
- Solicitation number
- PE-56300-RFQ-2026-000000022
- Issued by
- Dooly County, Georgia
About this file
This is a bid set document prepared by New Brick Architects for the College of Coastal Georgia located in Brunswick, Georgia, detailing a Student Activity Center Fascia and Soffit Replacement project. The project scope includes removal of existing asbestos paneling and plywood soffit materials, installation of new fiber cement panels with continuous non-corrosive aluminum trim at all panel joints, replacement of structural support components, and installation of new galvanized 1-1/2" hat channels spaced at 12" on-center maximum with neoprene tabs on existing metal struts designed to withstand 140 mph wind loads. The bid set, issued on August 22, 2025, comprises architectural drawings across three sheets (A101 covering floor plan and elevations, A102 containing detailed elevation and section views, and A103 showing reflected ceiling plans) with specifications referencing multiple 2018 International Building Codes and related standards with Georgia amendments current through 2024, along with the 2020 National Electrical Code with 2021 Georgia amendments. The project requires general contractor field verification of existing conditions, structural inspection and repair of the existing metal support system, removal of surface rust, and replacement of any structurally damaged members prior to new material installation.
The document does not contain specific pricing terms, contract award dates, response deadlines, site visit schedules, bidder conference information, set-asides, incumbent contractor details, or funding source documentation. All existing components are noted for review with the owner prior to construction commencement, and the contractor is responsible for compliance verification with all applicable codes and amendments enforced by the local authority having jurisdiction. The plans indicate multiple elevation views with existing dimensions to be field-verified by the general contractor, including perimeter measurements of approximately 221 to 222 linear feet and various soffit heights ranging from 4 to 16 feet 8 inches.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 250822_CCGA_StudentActivityCenter_BidSet_Spec.pdf | ||
| SPD_AP005 Notice of Award for SAC.doc | DOC document | |
| BID Invitation SAC Fascia and Soffit.docx | DOCX document | |
| STATEMENT OF BIDDER QUALIFICATIONS.docx | DOCX document | |
| Bid Tab CCGA_2610.pdf | ||
| SPD_AP004 Notice of Intent Award CCGA 2610 SA.pdf | ||
| DBB_Full_Document_May_2025.docx | DOCX document | |
| PreBid Meeting Sheet CCGA 2610 SAC Fascia and.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EX
IS
TI
N G
-G C
T O
F
IE
LD
V
ER
IF
Y
221' - 11" +/- EXISTING -GC FIELD VERIFY
A102
A1022
A102 3
1 2 3 4 5 6 7 8 9 10 11 12
EXISTING TO REMAIN
EXISTING WALL
TO REMAIN
EX
IS
TI
N G
-G C
T O
F
IE
LD
V
ER
IF
Y
N
EW
B R
O C
K
AR
C H
IT
EC
TS
C U
R R
EN
T
R
EV
IS
IO
N N
O
C U
R R
EN
T
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N C
U R
R
EN
T R
EV
IS
IO
N
D
AT
E
ORIGINAL ISSUE DATE
N
EW
BR
O
C K.
C O
M
IN
FO
N
EW
BR
O
C K.
C O
M
C O
VE
R
S H
EE
T-
FL
O
O R
P
LA
N
C O
LL
EG
E O
F C
O
AS
TA
L
G
EO
R G
IA
-S
TU
D
EN
T
AC
TI
VI
TY
C
EN
TE
R
-F
AS
C
IA
A N
D S
O
FF
IT
R
EP
LA
C
EM
EN
T
8/22/2025
BID SET
A101
1 C
OL
LE
GE
D
RI
VE
B
RU
NS
W
IC
K, G A
SCALE: 1/8" = 1'-0"A101
1 SAC- FLOOR PLAN
General Contractor to verify the following codes are currently enforced with all AHJ and that all are implemented for all work:
• International Building Code, 2018 Edition, with Georgia Amendments (2020-2024)
• International Residential Code, 2018 Edition, with Georgia Amendments (2020-2024)
• International Fire Code, 2018 Edition, (State Fire Marshal Office)
• Life Safety Code NFPA 101, 2018 Edition, State Fire Marshal Office
• International Plumbing Code, 2018 Edition, with Georgia Amendments (2020-2024)
• International Mechanical Code, 2018 Edition, with Georgia Amendments (2020-2024)
• International Fuel Gas Code, 2018 Edition, with Georgia Amendments (2020-2024)
• International Swimming Pool and Spa Code, 2018 Edition, with Georgia Amendments (2020-2024)
• National Electrical Code, 2020 Edition with Georgia Amendments 2021
• International Energy Conservation Code, 2015 Edition, with Georgia Supplements and Amendments (2020-2024)
• International Property Maintenance Code, 2012 Edition, with Georgia Amendments (2015-2024)
• International Existing Building Code, 2012 Edition, with Georgia Amendments (2015-2024)
• International Residential Code High Wind Region, 2009
SHEET INDEX:
A101: COVER SHEET-FLOOR PLAN
A102: ELEVATIONS AND SECTION DETAILS
A103: REFLECTED CEILING PLAN
1 2 3 4 5 6 7 8 9 10 11 12
NEW FIBER CEMENT
PANELS WITH CONT.
NON-CORROSIVE
ALUM. TRIM @ ALL
PANEL JOINTS
NEW FIBER CEMENT
PANELS WITH CONT.
NON-CORROSIVE
ALUM. TRIM @ ALL
PANEL JOINTS
NEW FIBER CEMENT
PANELS WITH CONT.
NON-CORROSIVE
ALUM. TRIM @ ALL
PANEL JOINTS
G C
T O
F
IE
LD
V
E R
IF
Y
E
X
IS
T
IN
G
NEW GALVANIZED 1-1/2"
HAT CHANNELS @ 12"
O.C. MAX. ON NEOPRENE
TABS ON EXISTING
METAL STRUTS WITH
FASTENERS TO
WITHSTAND 140 MPH
WIND
NEW FIBER CEMENT
PANELS WITH CONT.
NON-CORROSIVE
ALUM. TRIM @ ALL
PANEL JOINTS
EXISTING METAL STRUCTURAL SUPPORT SYSTEM TO
REMAIN- GC TO INSPECT ALL EXISTING METAL
STRUCTURAL SUPPORT SYSTEM- CLEAN TO REMOVE ALL
EXISTING SURFACE RUST AND REMOVE AND REPLACE
ANY AND ALL MEMBERS WITH STRUCTURAL DAMAGE
EXISTING TO
REMAIN
NEW FIBER CEMENT
PANELS WITH CONT.
NON-CORROSIVE
ALUM. TRIM @ ALL
PANEL JOINTS
EXISTING GUTTERS
AND DOWNSPOUTS
TO REMAIN
N E
W B
R O
C K
A R
C H
IT
E
C T
S
C U
R R
E N
T
R
V
IS
IO
N
N O
C
U R
R E
N T
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N C
U R
R E
V
IS
IO
N D
A T
E
ORIGINAL ISSUE DATE
N E
W B
R O
C K
.C O
M
IN
F O
N
E W
B R
O C
K .C
O M
E L
E V
A T
IO
N
S A
N D
S E
C T
IO
N
D E
T A
IL
S
C O
L
LE
G E
O F
C O
A S
T A
L G
E O
R G
IA
S T
U D
E N
T A
C T
IV
IT
Y C
E N
T E
R
F A
S C
IA
A
N D
S O
F F
IT
R
E P
L A
C E
M E
N T
8/22/2025
BID SET
A102
C
O
LL
EG
E
D R
IV
U
N
SW
IC
K, G A
SCALE: 3/4" = 1'-0"A102
4 FASCIA AND SOFFIT DETAIL- ORIGINAL FOR REFERENCE
SCALE: 1/8" = 1'-0"A102
2 SAC- SOUTH ELEVATION
SCALE: 1/8" = 1'-0"A102
1 SAC- WEST FRONT ELEVATION
SCALE: 1/8" = 1'-0"A102
3 SAC- NORTH ELEVATION
SCALE: 3/4" = 1'-0"A102
5 FASCIA AND SOFFIT DETAIL
SCALE: 12" = 1'-0"A102
6 PHOTOS OF EXISTING CONDITIONS
EXISTING TO REMAIN
GC REVIEW EXISTING
SUPPORTS THIS WALL- REPAIR, PATCH,
REPLACE, INSTALL NEW STRUCTURAL
SUPPORT TO PROVIDE SUFFICIENT
SUPPORT FOR NEW INSTALL OF
FIBER CEMENT PANELS AND SOFFIT
TO CREATE LIKE NEW CONDITIONS
TO MATCH OPP HAND INSTALL WITH
MATCHING ALUM. FIBER CEMENT TRIM-
REVIEW WITH OWNER AND ARCHITECT
NEW FIBER CEMENT
SOFFIT PANELING- SEE
DETAILS AND SPECS-
REVIEW WITH OWNER AND
ARCHITECT
-G C
T O
F
IE
L D
V E
R
IF
Y
E
X
IS
T
IN
G
-G C
T O
F
IE
L D
V E
R
IF
Y
E
X
IS
T
IN
G
-GC TO FIELD VERIFY
4' - 0" +/- EXISTING
GC- TO FIELD VERIFY
222' - 3" +/- EXISTING
-GC TO FIELD VERIFY
4' - 0" EXISTING
4' - 0"
NEW FIBER CEMENT
SOFFIT PANELING- SEE
DETAILS AND SPECS-
REVIEW WITH OWNER AND
ARCHITECT
NEW FIBER CEMENT
SOFFIT PANELING- SEE
DETAILS AND SPECS-
REVIEW WITH OWNER AND
ARCHITECT
NEW FIBER CEMENT
SOFFIT PANELING- SEE
DETAILS AND SPECS-
REVIEW WITH OWNER AND
ARCHITECT
GC TO REMOVE ALL
EXISTING AESBESTOS
PANELING PER ALL CODES,
LAWS, SPECS AND
DETAILS- REVIEW WITH
OWNER AND ARCHITECT
GC TO REMOVE ALL
EXISTING PLYWOOD
SOFFIT AND PANELING
HERE
-G C
T O
F
IE
L D
V E
R
IF
Y
E
X
IS
T
IN
G
E
X
IS
T
IN
G
G C
T O
F
IE
L D
V E
R
IF
Y
ALL EXISTING COMPONENTS TO BE REVIEWED WITH OWNER PRIOR TO START OF CONSTRUCTION
N E
W B
R O
C K
A R
C H
IT
E
C T
S
C U
R R
E
V
IS
IO
N
N O
C
U R
R E
N T
R E
V
IS
IO
N
D E
S C
R
IP
T
IO
N C
U R
R E
V
IS
IO
N D
A T
E
ORIGINAL ISSUE DATE
N E
W B
R O
C K
.C O
M
IN
F O
N
E W
B R
O C
K .C
O M
R E
F L
E C
T E
D C
E
IL
IN
G
P L
A N
C O
L
LE
G E
O F
C O
A S
T A
L G
E O
R G
IA
S T
U D
E N
T A
C T
IV
IT
Y C
E N
T E
R
F A
S C
IA
A
N D
S O
F F
IT
R
E P
L A
C E
M E
N T
8/22/2025
BID SET
A103
C
O
LL
EG
E
D R
IV
U
N
SW
IC
K, G A
SCALE: 1/8" = 1'-0"A103
1 REFLECTED CEILING PLAN
SCALE: 12" = 1'-0"A103
2 PHOTOS OF EXISTING CONDITIONS 2
File details come from the government source that posted it. Updated .