25-8378_-_Exhibit_M_-_Sun_N_Fun_IWF_PL_Drawings_-_100%_Bid_Set.pdf
PDF 15 MB Posted
- Attached to
- Sun-n-Fun Interactive Water Features Renovations
- Solicitation number
- 25-8378
- Issued by
- Collier County, Florida
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
-36" -36"-36"
-42" -42" -42"
-42" -42" -42"
S P E A R S
S P E A R S
S P
EA
R S
S P
EAR
S
R Y
E N T
N O
RY
E
NT
N O
RY ENT NO RY ENT NO RY ENT NO
RY
EN
T
NO
R Y
E N T
N O
R Y
E N T
N O
RYENTNORYENTNORYENTNO
RY
E
NT
NO
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-36"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-42"
-42"
-42"
-42"
-42"
-36"
-42"
-42"
-42"
-42"
-42"
POOL E - IWF
SEE D101.E FOR
DEMO PLANS
AND PL130.E
FOR NEW
WORK.
POOL D - PLUNGE POOL
SEE "D" SHEET
PACKAGE FOR ALL
DRAWINGS.
POOL C - LAZY RIVER
SEE "C" SHEET PACKAGE FOR
ALL DRAWINGS.
EXISTING RIVER FEATURE
PUMP ROOM PB3,
HOUSING RIVER FEATURE
AND PROPULSION PUMPS.
SEE "C" DRAWING
PACKAGE FOR MORE
INFO.
EXISTING SLIDE PUMP ROOM
PB2, HOUSING ALL SLIDE
PUMPS. NO WORK IN
CONTRACT.
EXISTING FILTRATION
MECHANICAL ROOM PB1,
HOUSING ALL POOLS'
FILTRATION EQUIPMENT
SEE PL400.E FOR
CHANGES REQUIRED
N
GENERAL NOTES:
1. LOCATE LIFEGUARD CHAIRS AS REQUIRED PER STATE AND LOCAL CODES AND PER OWNER'S SAFETY
CONSULTANT.
2. SCHEDULE QUANTITIES ARE SHOWN FOR VALUE ENGINEERING PURPOSES. IT IS THE INSTALLING CONTRACTOR'S
RESPONSIBILITY TO VERIFY QUANTITIES REQUIRED.
3. CONTRACTOR SHALL CONTACT ENGINEER FOR ELECTRONIC DRAWING FILES PRIOR TO COMMENCING POOL
STAKING WORK.
4. ENGINEER WILL PROVIDE ELECTRONIC PLAN VIEW OF ALL POOLS IN AUTOCAD DRAWING FORMAT FOR
CONTRACTOR'S USE TO LOCATE STRUCTURES AND RELATED POOL DECK EQUIPMENT.
5. REFER TO PL100 SERIES DRAWINGS FOR ALL POOL PLAN INFORMATION, RELATED EQUIPMENT, AND DETAILS.
6. REFER TO PL200 SERIES DRAWINGS FOR ALL POOL STRUCTURAL PLANS, RELATED INFORMATION, AND DETAILS.
7. REFER TO PL300 SERIES DRAWINGS FOR ALL POOL AND DRAIN PIPING AND RELATED INFORMATION AND DETAILS.
CODES, STANDARDS AND REGULATIONS:
CONTRACTOR SHALL BE FAMILIAR WITH ALL CODES AND STANDARDS LISTED BELOW AND ALERT THE
ARCHITECT/ENGINEER TO CONFLICTS IN THE DRAWINGS
CODE JURISDICTION
UNITED STATES / NAPLES / FLORIDA / COLLIER COUNTY
HEALTH & SAFETY CODE:
STATE HEALTH CODE: 2023 FBC SECTION 454.1 SWIMMING POOLS AND BATHING PLACES
COUNTY HEALTH CODE: FLORIDA ADMINISTRATIVE CODE CHAPTER 64E-9 - PUBLIC SWIMMING POOLS AND BATHING
PLACES
ACCESSIBILITY STANDARDS AND REGULATIONS:
UNITED STATES:
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
BATHER CAPACITY
BATHER CAPACITY IS CALCULATED IN ACCORDANCE WITH SECTION 454.1.1.1 OF THE 2023 FBC, 8TH EDITION, AS FOLLOWS:
1. POOL E:
a. 450 GPM / 5 GPM PER BATHER = 90 BATHERS.
2. TOTAL: 90 BATHERS
World Leaders in Aquatic Planning, Design and Engineering
100 Park Avenue | Beaver Dam, WI 53916 t 920.887.7375 This Document and the ideas, renderings and other contents contained therein are the sole property of Water Technology, Inc. and may not be disseminated, copied, reproduced or otherwise used without prior written consent of Water Technology, Inc.
DRAWINGS MUST BE
VIEWED AND PLOTTED
IN FULL COLOR.
PROJECT PHASE:
S U
N -N
-F U
N L
A G
O O
N
R E
N O
V A
T
IO
N S
L iv in g st o n
R d
N a p le s, F L
PL001.E
COVER
ISSUE DATE: 11/08/2024
PROJECT NUMBER: 22567
DRAWN BY: TJT
CHECKED BY: RIG
100% CONSTRUCTION DOCUMENTS
PLAN VIEW
12" = 1'-0"
PL001.E
2 LOCATION MAP
PLAN VIEW
12" = 1'-0"
PL001.E
3 VICINITY MAP
SUN-N-FUN LAGOON
RENOVATIONS POOL E -
INTERACTIVE WATER FEATURE
"IWF"
SCHEDULE - SHEET LIST POOL E
SHEET NO. SHEET NAME
CURRENT
REVISION
CURRENT REVISION
DESCRIPTION
CURRENT
REVISION DATE
PL001.E COVER
D101.E POOL E - IWF DEMO PLAN
D102.E POOL E - IWF PIPING DEMO PLAN
PL130.E POOL E - IWF SURGE TANK PLAN AND DIMENSION PLAN
PL131.E POOL E - IWF SECTION AND DETAILS
PL132.E POOL E - IWF DETAILS
PL200.E STRUCTURAL NOTES, PLAN(S) AND SCHEDULE
PL201.E POOL E - STRUCTURAL DETAILS
PL300.E OVERALL PIPING PLAN
PL301.E MECHANICAL NOTES
PL330.E POOL E - IWF PIPING PLAN
PL400.E POOL E - IWF MECHANICAL PLAN
PL401.E POOL E - IWF MECHANICAL DETAILS
PL402.E POOL E - IWF MECHANICAL DETAILS
PL500.E POOL E - IWF MECHANICAL P&ID
PLAN VIEW
1" = 30'-0"
PL001.E
1 OVERALL SITE PLAN
PROJECT CONTACTS:
POOL DESIGN / AQUATICS CONSULTANT
STRUCTURAL ENGINEERING CONSULTANT
WATER TECHNOLOGY INC.
100 PARK AVE
BEAVER DAM, WI 52916
920.887.7375
GRAEF CONSULTING ENGINEERS
116 S ADAMS STREET, STE 201
GREEN BAY, WI 54301
920.592.9440
REVISION SCHEDULE
Number Description Date
S
N
D102.E
13A
TYP.
TYP.
TYP.
13A
13A
13A
13A
13A
13A
13A
13A
13A
13A
13A 13A
13A
13A
13A
13A
R
GENERAL DEMOLITION NOTES:
1. ALL CONDITIONS SHOWN ON THIS DRAWING ARE EXISTING. OWNER AND
ARCHITECT ASSUME NO RESPONSIBILITY FOR ACCURACY OR COMPLETENESS
OF INFORMATION SHOWN. ORIGINAL CONSTRUCTION DOCUMENTS FOR
EXISTING FACILITY ARE ON FILE AT THE OWNER'S OFFICE FOR REVIEW.
CONTRACTORS ARE RESPONSIBLE TO VISIT THE SITE AND REVIEW ALL
DOCUMENTS PRIOR TO SUBMITTING THEIR BID TO COMPLETELY FAMILIARIZE
THEMSELVES WITH ALL CONDITIONS.
2. DEMOLITION DRAWINGS ARE INTENDED TO BE SCHEMATIC IN NATURE, AND MAY
NOT DESCRIBE ALL MISCELLANEOUS WORK NECESSARY TO COMPLETE THE
DEMOLITION AND NEW WORK. CONTRACTOR SHALL INCLUDE THIS
MISCELLANEOUS NECESSARY WORK IN BASE BID.
3. CONTRACTOR SHALL DISCONNECT AND REMOVE ALL EXISTING POOL
EQUIPMENT WITHIN THE LIMITS INDICATED WITH HATCHING ( ). SEE
DRAWING NOTES FOR EQUIPMENT THAT SHALL BE REUSED IN PLACE AND
EQUIPMENT THAT SHALL BE RELOCATED AND REUSED.
4. CONTRACTOR TO VERIFY ASBESTOS TEST REQUIREMENTS AND CONDUCT ANY
REQUIRED TESTING PRIOR TO CONSTRUCTION.
5. UNLESS NOTED OTHERWISE ON THE PLAN, CONTRACTOR SHALL DISPOSE OF
ALL REMOVED EQUIPMENT AND MATERIALS IN A LEGAL MANNER OFF SITE.
COPIES OF ALL MANIFESTS SHALL BE GIVEN TO THE OWNER SHOWING FINAL
DISPOSAL LOCATION OF ALL MATERIALS.
6. CONTRACTOR SHALL MAINTAIN DUST CONTROL INSIDE AND OUTSIDE OF THE
BUILDING AT ALL TIMES.
7. CONTRACTOR SHALL PROTECT ALL CATCH BASINS, SEWER INLETS, ETC., FROM
DEBRIS AND SEDIMENTATION DURING DEMOLITION.
8. CONTRACTOR SHALL LIMIT THE EXTENT OF HIS DISRUPTION TO THE INDICATED
WORK AREA, AND TAKE CARE NOT TO DISRUPT THE SURROUNDING AREA.
9. CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND TERMINATING
EXISTING ELECTRICAL POWER, WATER, AND GAS LINES WITH LOCAL UTILITIES.
10. SEE PL400.E FOR MECHANICAL ROOM/EQUIPMENT DEMOLTION SCOPE.
11. PROJECT RENOVATION WORK INCLUDES THE REMOVAL OF ALL EXISTING SPRAY
CANS; CERTAIN FEED PIPING TO THE CANS WILL BE REUSED FOR NEW
FEATURES; SEE THE KEYED NOTES. FOR THE UNUSED FEED PIPING,
CONTRACTOR SHALL PROVIDE AN AS-BUILT DRAWING WITH COORDINATES OF
THE CAPPED AND BURIED FEED PIPING TO THE OWNER FOR THEIR USE DURING
FUTURE FEATURE INSTALLATION.
DEFINITIONS:
A. REMOVE: REMOVE AND LEGALLY DISPOSE OF ITEMS EXCEPT THOSE INDICATED
TO BE REINSTALLED, SALVAGED, OR TO REMAIN THE OWNER'S PROPERTY.
B. REMOVE AND SALVAGE: ITEMS INDICATED TO BE REMOVED AND SALVAGED
REMAIN THE OWNER'S PROPERTY. REMOVE, CLEAN, AND PACK OR CRATE
ITEMS TO PROTECT AGAINST DAMAGE. IDENTIFY CONTENTS OF CONTAINERS
AND DELIVER TO OWNER'S DESIGNATED STORAGE AREA.
C. REMOVE AND REINSTALL: REMOVE ITEMS INDICATED; CLEAN, SERVICE, AND
OTHERWISE PREPARE THEM FOR REUSE; STORE AND PROTECT AGAINST
DAMAGE. REINSTALL ITEMS IN THE SAME LOCATIONS OR IN LOCATIONS
INDICATED.
D. EXISTING TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN
AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN
PERMITTED BY THE OWNER OR ARCHITECT, ITEMS MAY BE REMOVED TO A
SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION
AND THEN CLEANED AND REINSTALLED IN THEIR ORIGINAL LOCATIONS.
E. ABANDON: PERMANENTLY REMOVE FROM SERVICE AND MAINTAIN IN PLACE.
FOR PIPING, ABANDONED PIPES SHALL BE BLOWN OUT, DISCONNECTED FROM
OTHER PIPING AND DISCONNECTED FROM THE POOL WALL/TANK WALL. PIPING
ENDS SHALL BE CAPPED ON BOTH ENDS. FOR PIPE PENETRATING FINISHED
SURFACES, CUT BACK PIPE SUCH THAT CAPS ARE A MINIMUM OF 3” BELOW
FINISHED SURFACE. COVER WITH NON-SHRINK, NON-METALLIC GROUT AND
SPECIFIED FINISHES. ABANDONED PIPING SHALL BE IDENTIFIED IN RECORD
DRAWINGS PROVIDED BY THE CONTRACTOR.
World Leaders in Aquatic Planning, Design and Engineering
100 Park Avenue | Beaver Dam, WI 53916 t 920.887.7375 This Document and the ideas, renderings and other contents contained therein are the sole property of Water Technology, Inc. and may not be disseminated, copied, reproduced or otherwise used without prior written consent of Water Technology, Inc.
DRAWINGS MUST BE
VIEWED AND PLOTTED
IN FULL COLOR.
PROJECT PHASE:
S U
N -N
-F U
N L
A G
O O
N
R E
N O
V A
T
IO
N S
L iv in g st o n
R d
N a p le s, F L
D101.E
POOL E - IWF DEMO PLAN
ISSUE DATE: 11/08/2024
PROJECT NUMBER: 22567
DRAWN BY: TJT
CHECKED BY: RIG
100% CONSTRUCTION DOCUMENTS
PLAN VIEW
1/4" = 1'-0"
D101.E
1 POOL E - IWF SPRAY PAD OVERALL DEMO PLAN
KEYED NOTES:
1. REMOVE EXISTING FIBERGLASS COLLECTOR TANK, TYP OF 2. EXCAVATE MINIMUM 2'
AROUND TANK TO EXPOSE CONNECTED PIPING. CUT PIPING OUTSIDE OF TANK, CAP,
AND PROTECT FOR REUSE.
2. SEE D102.E.
3. SEE D102.E.
4. SEE D102.E.
5. SEE D102.E.
6. SEE D102.E.
7. SEE D102.E.
8. SEE D102.E.
9. SEE D102.E.
10. SEE D102.E.
11. SEE D102.E.
12. LINE INDICATES EXTENT OF EXISTING 2,826 SF IWF/SPRAY PAD SLOPED TOWARD THE
CENTER. REMOVE EXISTING SLAB PER THE HATCH PATTERN. REMOVE EXISTING
FINISH ON THE REMAINDER OF THE SPRAY PAD IN PREPARATION FOR NEW FINISH.
13. REMOVE EXISTING SPRAY CANS, TYP OF 64. EACH SPRAY CAN IS SUPPLIED BY A 1.5"
FEED PIPE AND HAS A 3" DRAIN CONNECTION. DRAIN IN EACH CAN SHALL BE
ABANDONED; PLUG DRAIN PIPING AT SPRAY CAN WITH HYDRAULIC CEMENT. PROTECT
THE 1.5" FEED PIPING UNDER EACH CAN FOR CONNECTION TO NEW FEATURE.
A. TAGGED SPRAY CAN INDICATES 1.5" FEED PIPING SHALL BE REUSED FOR NEW
FEATURE. CAP AND PROTECT FEED PIPING DURING DEMO FOR PIPING
RECONNECTION. ALL UNUSED FEED PIPING FROM OTHER REMOVED SPRAY
CANS SHALL BE CAPPED AND PROTECTED DURING DEMO. SEE GENERAL
DEMO NOTE 11 ON THIS PAGE FOR INSTRUCTIONS FOR UNUSED SPRAY CAN
PIPING.
14. REMOVE EXISTING 10" DIAMETER METAL FLOOR DRAIN, TYP OF 21. EACH FLOOR DRAIN
IS CONNECTED BY A 3" PIPE; REMOVE ALL 3" LATERAL PIPING AND ANY GRAVITY MAINS
BACK TO THE DEMO REGION INDICATED ON THE PLAN. SEE NEW PIPING PLANS FOR
GRAVITY PIPING CONNECTION TO THE NEW SPRAY PAD FLOOR DRAINS.
15. APPROXIMATE EXTENT OF THE SLAB DEMO IS DEFINED BY RADIAL DIMENSION NOTED;
THIS DIMENSION ALLOWS FOR ENOUGH ROOM FOR NEW SLAB AND FEATURE
FOUNDATION INSTALL. CONTRACTOR SHALL FIELD LOCATE THE CENTER POINT OF
THE DEMO CIRCLE AND SAW CUT SLAB TO THE DIMENSION NOTED ON THE DEMO
PLAN.
S
6"ø
14"ø
14"ø
6"ø
10"ø
6"ø
12"ø
6"ø
6"ø
14"ø
14"ø
12"ø 12"ø
10"ø
10"ø
10"ø
10"ø
8"ø
6"ø
10"ø
2"ø
2"ø
EXISTING PIPING
CONTINUES TO PB#1
12"ø
N
EXISTING AUTOFILL SENSOR
ASSEMBLY. DISCONNECT AND
REMOVE PROXY SENSOR AND
PIPING/FITTINGS IN THE TANK.
PROTECT CABLE FOR REUSE AND
ATTACHMENT TO NEW SENSOR.
EXISTING SOLENOID VALVE FOR
FILL. REMOVE VALVE AND ALL
ADDITIONAL PIPING AND FITTINGS
CONNECTED TO FILL LOOP. SEE
NEW DETAILS FOR
REINSTALLATION.
GENERAL DEMOLITION NOTES:
1. ALL CONDITIONS SHOWN ON THIS DRAWING ARE EXISTING. OWNER AND
ARCHITECT ASSUME NO RESPONSIBILITY FOR ACCURACY OR COMPLETENESS
OF INFORMATION SHOWN. ORIGINAL CONSTRUCTION DOCUMENTS FOR
EXISTING FACILITY ARE ON FILE AT THE OWNER'S OFFICE FOR REVIEW.
CONTRACTORS ARE RESPONSIBLE TO VISIT THE SITE AND REVIEW ALL
DOCUMENTS PRIOR TO SUBMITTING THEIR BID TO COMPLETELY FAMILIARIZE
THEMSELVES WITH ALL CONDITIONS.
2. DEMOLITION DRAWINGS ARE INTENDED TO BE SCHEMATIC IN NATURE, AND MAY
NOT DESCRIBE ALL MISCELLANEOUS WORK NECESSARY TO COMPLETE THE
DEMOLITION AND NEW WORK. CONTRACTOR SHALL INCLUDE THIS
MISCELLANEOUS NECESSARY WORK IN BASE BID.
3. CONTRACTOR SHALL DISCONNECT AND REMOVE ALL EXISTING POOL
EQUIPMENT WITHIN THE LIMITS INDICATED WITH HATCHING ( ). SEE
DRAWING NOTES FOR EQUIPMENT THAT SHALL BE REUSED IN PLACE AND
EQUIPMENT THAT SHALL BE RELOCATED AND REUSED.
4. CONTRACTOR TO VERIFY ASBESTOS TEST REQUIREMENTS AND CONDUCT ANY
REQUIRED TESTING PRIOR TO CONSTRUCTION.
5. UNLESS NOTED OTHERWISE ON THE PLAN, CONTRACTOR SHALL DISPOSE OF
ALL REMOVED EQUIPMENT AND MATERIALS IN A LEGAL MANNER OFF SITE.
COPIES OF ALL MANIFESTS SHALL BE GIVEN TO THE OWNER SHOWING FINAL
DISPOSAL LOCATION OF ALL MATERIALS.
6. CONTRACTOR SHALL MAINTAIN DUST CONTROL INSIDE AND OUTSIDE OF THE
BUILDING AT ALL TIMES.
7. CONTRACTOR SHALL PROTECT ALL CATCH BASINS, SEWER INLETS, ETC., FROM
DEBRIS AND SEDIMENTATION DURING DEMOLITION.
8. CONTRACTOR SHALL LIMIT THE EXTENT OF HIS DISRUPTION TO THE INDICATED
WORK AREA, AND TAKE CARE NOT TO DISRUPT THE SURROUNDING AREA.
9. CONTRACTOR IS RESPONSIBLE FOR COORDINATING AND TERMINATING
EXISTING ELECTRICAL POWER, WATER, AND GAS LINES WITH LOCAL UTILITIES.
10. SEE PL400.E FOR MECHANICAL ROOM/EQUIPMENT DEMOLTION SCOPE.
11. PROJECT RENOVATION WORK INCLUDES THE REMOVAL OF ALL EXISTING SPRAY
CANS; CERTAIN FEED PIPING TO THE CANS WILL BE REUSED FOR NEW
FEATURES; SEE THE KEYED NOTES. FOR THE UNUSED FEED PIPING,
CONTRACTOR SHALL PROVIDE AN AS-BUILT DRAWING WITH COORDINATES OF
THE CAPPED AND BURIED FEED PIPING TO THE OWNER FOR THEIR USE DURING
FUTURE FEATURE INSTALLATION.
DEFINITIONS:
A. REMOVE: REMOVE AND LEGALLY DISPOSE OF ITEMS EXCEPT THOSE INDICATED
TO BE REINSTALLED, SALVAGED, OR TO REMAIN THE OWNER'S PROPERTY.
B. REMOVE AND SALVAGE: ITEMS INDICATED TO BE REMOVED AND SALVAGED
REMAIN THE OWNER'S PROPERTY. REMOVE, CLEAN, AND PACK OR CRATE
ITEMS TO PROTECT AGAINST DAMAGE. IDENTIFY CONTENTS OF CONTAINERS
AND DELIVER TO OWNER'S DESIGNATED STORAGE AREA.
C. REMOVE AND REINSTALL: REMOVE ITEMS INDICATED; CLEAN, SERVICE, AND
OTHERWISE PREPARE THEM FOR REUSE; STORE AND PROTECT AGAINST
DAMAGE. REINSTALL ITEMS IN THE SAME LOCATIONS OR IN LOCATIONS
INDICATED.
D. EXISTING TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN
AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN
PERMITTED BY THE OWNER OR ARCHITECT, ITEMS MAY BE REMOVED TO A
SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION
AND THEN CLEANED AND REINSTALLED IN THEIR ORIGINAL LOCATIONS.
E. ABANDON: PERMANENTLY REMOVE FROM SERVICE AND MAINTAIN IN PLACE.
FOR PIPING, ABANDONED PIPES SHALL BE BLOWN OUT, DISCONNECTED FROM
OTHER PIPING AND DISCONNECTED FROM THE POOL WALL/TANK WALL. PIPING
ENDS SHALL BE CAPPED ON BOTH ENDS. FOR PIPE PENETRATING FINISHED
SURFACES, CUT BACK PIPE SUCH THAT CAPS ARE A MINIMUM OF 3” BELOW
FINISHED SURFACE. COVER WITH NON-SHRINK, NON-METALLIC GROUT AND
SPECIFIED FINISHES. ABANDONED PIPING SHALL BE IDENTIFIED IN RECORD
DRAWINGS PROVIDED BY THE CONTRACTOR.
World Leaders in Aquatic Planning, Design and Engineering
100 Park Avenue | Beaver Dam, WI 53916 t 920.887.7375 This Document and the ideas, renderings and other contents contained therein are the sole property of Water Technology, Inc. and may not be disseminated, copied, reproduced or otherwise used without prior written consent of Water Technology, Inc.
DRAWINGS MUST BE
VIEWED AND PLOTTED
IN FULL COLOR.
PROJECT PHASE:
S U
N -N
-F U
N L
A G
O O
N
R E
N O
V A
T
IO
N S
L iv in g st o n
R d
N a p le s, F L
D102.E
POOL E - IWF PIPING DEMO PLAN
ISSUE DATE: 11/08/2024
PROJECT NUMBER: 22567
DRAWN BY: TJT
CHECKED BY: RIG
100% CONSTRUCTION DOCUMENTS
PLAN VIEW
1/2" = 1'-0"
D102.E
1 POOL E - ENLARGED COLLECTOR TANK PIPING DEMO
NOT TO SCALE
DETAIL VIEWD102.E
2 EXISTING IWF COLLECTOR TANK AUTOFILL
KEYED NOTES:
1. REMOVE EXISTING FIBERGLASS COLLECTOR TANK, TYP OF 2. EXCAVATE MINIMUM 2'
AROUND TANK TO EXPOSE CONNECTED PIPING. CUT PIPING OUTSIDE OF TANK, CAP,
AND PROTECT FOR REUSE.
2. PIPING SHOWN IN DETAIL 1 IS SCHEMATIC ONLY AND REPRESENTS THE CONDITIONS
FROM THE DESIGN DRAWINGS. AS-BUILT CONDITIONS WILL VARY FROM THIS
SCHEMATIC. CONTRACTOR SHALL DOCUMENT THE AS-BUILT CONDITIONS WITH
PHOTOS DURING EXCAVATION. PIPING WITH A FADED BACKGROUND IS EXISTING TO
REMAIN.
3. TWO EXISTING 14" PIPES ASSUMED FOR IWF DRAINAGE. PROTECT PIPING FOR
REUSE AND TIE INTO NEW SURGE TANK.
4. TWO EXISTING 14" PIPES ASSUMED FOR SPRAY CAN FEATURE DRAINS. PIPING TO BE
ABANDONED. CAP PIPES BELOW GRADE NEAR EXISTING COLLECTOR TANK, AND
REMOVE EXISTING SPRAY CAN DRAINS PER KEYNOTE 13.
5. 12" TRANSFER PIPE TO BALANCE WATER LEVEL BETWEEN THE 2 TANKS. THIS PIPE
WAS NOT FOUND DURING SITE EVALUATION, BUT IF IT EXISTS, IT SHALL BE REMOVED
AND WILL NOT BE REUSED.
6. TWO EXISTING 2" PIPES FOR AUTOFILL SENSOR AND FILL LINE. PROTECT PIPES FOR
REUSE. REROUTE TO NEW SURGE TANK. SEE DEMO IMAGE THIS SHEET FOR MORE
INFO.
7. EXISTING 8" FILTRATION SUPPLY PIPE TO SURGE TANK. DEMO ANY INDIVIDUAL
LATERALS TO EACH EXISTING TANK AND PROTECT 8" MAIN FOR REUSE.
8. EXISTING 10" FILTER PUMP SUCTION, CONNECTED TO A HEADER IN FASHION SIMILAR
TO THE PIPING SCHEMATIC. PROTECT THE 10" MAIN AND REMOVE THE
HEADER/LATERALS DOWNSTREAM TO THE COLLECTOR TANKS.
9. EXISTING 12" FEATURE PUMP SUCTION, CONNECTED TO A HEADER IN FASHION
SIMILAR TO THE PIPING SCHEMATIC. PROTECT THE 12" MAIN AND REMOVE THE
HEADER/LATERALS DOWNSTREAM TO THE COLLECTOR TANKS.
10. EXISTING 6" SKIMMER SUCTION TO FILTER PUMP IN PB#1. DISCONNECT PIPING NEAR
TANK AS SHOWN. PROTECT MAIN RUN BACK TO PB#1 FOR REUSE.
11. EXISTING 12" FEATURE PUMP SUPPLY FROM PUMP BUILDING #1 TO REMAIN.
PROTECT FOR REUSE. SEE NEW PIPING PLAN FOR ROUTING TO NEW FEATURES.
12. SEE D101.E.
13. SEE D101.E.
14. SEE D101.E.
15. SEE D101.E.
EXISTING ELEVATION:
1. ELEVATIONS TAGGED ON THIS PLAN ARE EXTRACTED FROM A SURVEY CONDUCTED BY CPH, INC. IN 2020, DURING AN INITIAL PHASE OF WORK AT SUN-N-FUN LAGOON. EXISTING SPRAY PAD ELEVATIONS ARE APPROXIMATE AND GENERALLY FOLLOW THE SLOPE LINES IDENTIFIED ON PLAN, WITH THE LOW POINT BEING THE CENTER OF THE PAD. ON-SITE ELEVATIONS MAY VARY, AND IT IS IMPERATIVE THAT
NEW CONCRETE WORK MATCHES EXISTING CONCRETE SLOPES/PROFILES FOR PROPER DRAINAGE.
F02
F08
F05
F07
F06
F05
F09
F03
F04
F02
F02 F03
F01
F01
F03
F03
15.51' IWF FFE
PL131.E
PL131.E
PL131.E
F01
PL131.E
PL131.E
PL131.E
PL131.E
PL131.E
PL131.E
PL131.E
PL131.E
PL131.E
PL131.E
DASHED LINE INDICATES
EXTENT OF NEW
CONCRETE. SEE
STRUCTURAL DRAWINGS
FOR CONNECTION.
PL131.E
BASE BID IS THAT NEW CONCRETE SHALL MATCH THE
FINISH OF THE EXISTING (BROOM FINISH). ALTERNATE #1:
PROVIDE LIFEFLOOR FINISH FOR THE ENTIRE 2,826 SF
SPRAY PAD. INCLUDE TRANSITION STRIPS AT EDGE OF
SPRAY PAD TO MATCH TOP OF PADDING WITH EXISTING
CONCRETE FINISH ELEVATION.
F01
16.33' IWF FFE
16.08' IWF FFE
16.08' IWF FFE
PL132.E
PL132.E
PL132.E
PL132.E
PL132.E
PL132.E
PL132.E
PL131.E
15.58' IWF FFE
15.51' IWF FFE
15.58' IWF FFE
N
COLLECTOR TANK OUTSIDE WALL
COLLECTOR TANK FLOOR
POOL DECK
EQUIPOTENTIAL BONDING GRID,
TYPICAL AROUND EACH POOL, TANK,
AND/OR SPRAY PAD BY DECK
CONTRACTOR. SEE ELECTRICAL
DRAWINGS AND NOTES BELOW
POOL, TANK, AND/OR SPRAY
PAD REINFORCING STEEL
BONDING WIRE PER NEC 680,
BY ELECTRICAL
CONTRACTOR
NOTES:
1. THIS DETAIL IS INTENDED TO ILLUSTRATE THE EQUIPOTENTIAL BONDING GRID AROUND EACH POOL, TANK, AND/OR SPRAY
PAD AS REQUIRED BY NEC 680.
2. THE GRID SHALL CONFORM TO ALL NEC 680 REQUIREMENTS.
3. PER NEC 680, THE GRID SHALL:
3.a. COMPLETELY SURROUND THE PERIMETER OF THE POOL, TANK, AND/OR SPRAY PAD AND EXTEND 3 FEET HORIZONTALLY FROM THE INSIDE WALLS OF THE POOL, AND/OR TANK, OR PERIMETER EXPANSION JOINT AT SPRAY PADS.
3.b. BE ARRANGED IN A 12" X 12" (OR LESS) NETWORK OF CONDUCTORS IN A UNIFORMLY SPACED PATTERN.
3.c. BE BONDED TO THE POOL, TANK, AND/OR SPRAY PAD REINFORCING STEEL.
4. THIS DETAIL IS NOT INTENDED TO DETAIL THE WALLS, SLABS, OR THE DECKS. THE ABOVE DETAIL IS SCHEMATIC. SEE POOL, TANK, AND/OR SPRAY PAD SECTIONS AND DECK SECTIONS FOR ADDITIONAL CONSTRUCTION REQUIREMENTS.
5. SEE POOL, TANK, AND/OR SPRAY PAD ELECTRICAL DRAWINGS FOR ADDITIONAL BONDING & GROUNDING REQUIREMENTS.
World Leaders in Aquatic Planning, Design and Engineering
100 Park Avenue | Beaver Dam, WI 53916 t 920.887.7375 This Document and the ideas, renderings and other contents contained therein are the sole property of Water Technology, Inc. and may not be disseminated, copied, reproduced or otherwise used without prior written consent of Water Technology, Inc.
DRAWINGS MUST BE
VIEWED AND PLOTTED
IN FULL COLOR.
PROJECT PHASE:
S U
N -N
-F U
N L
A G
O O
N
R E
N O
V A
T
IO
N S
L iv in g st o n
R d
N a p le s, F L
PL130.E
POOL E - IWF SURGE TANK PLAN AND
DIMENSION PLAN
ISSUE DATE: 11/08/2024
PROJECT NUMBER: 22567
DRAWN BY: TJT
CHECKED BY: RIG
100% CONSTRUCTION DOCUMENTS
BACKWASH FLOW (EXISTING) NO CHANGE GPM
FILTRATION RATE (EXISTING) 8.9 GPM/FT²
TURNOVER/VOLUME/FLOW 15 MIN. 4,115 GAL. 274 GPM
CIRCULATION RATE 274 GPM
TOTAL VOLUME OF WATER 4,115 GALLONS
+ SURGE TANK OPERATING VOLUME 3,615 GALLONS
WATER FEATURE STORAGE VOLUME 500 GALLONS
SPRAY PAD TEMPERATURE 84 °F
SPRAY PAD SURFACE AREA 2,826 SQUARE FEET
SPRAY PAD PERIMETER 189 FEET
DESCRIPTION QTY UNITS
POOL E-IWF DATA
PLAN VIEW
1/4" = 1'-0"
PL130.E
1 POOL E - IWF PLAN
SCHEDULE - WATER FEATURE - POOL E
POOL ID FEATURE ID FEATURE QTY MANUFACTURER DESCRIPTION GPM (ea) GPM (Total)
E F01 GROUND SPRAY 4 WATERPLAY SOLO SPURT 1 4
E F02 GROUND SPRAY 3 WATERPLAY LILY PAD 6 18
E F03 GROUND SPRAY 4 WATERPLAY THE WAVE 3 12
E F04 WATER FEATURE 1 WATERPLAY 0010-0497 - MAGNIF-EYE - SMALL PLAYPHASE
BASE
3 3
E F05 WATER FEATURE 2 WATERPLAY 0011-0096 - SHARK - SMALL PLAYPHASE BASE 1.5 3
E F06 WATER FEATURE 1 WATERPLAY 0011-4264 - CROW'S NEST - MEDIUM PLAYPHASE
BASE
8 8
E F07 WATER FEATURE 1 WATERPLAY 0011-4296 - WHALE TAIL - MEDIUM PLAYPHASE
BASE
10 10
E F08 WATER FEATURE 1 WATERPLAY 0011-4273 - OGOPOGO - MEDIUM PLAYPHASE
BASE
16 16
E F09 WATER FEATURE 1 WATERPLAY 0010-0428 - CARRONADE CANNON - SMALL
PLAYPHASE BASE
6 6
DETAIL VIEW
3" = 1'-0"
PL130.E
2 POOL EQUIPOTENTIAL BONDING GRID
REVISION SCHEDULE
Number Description Date
FILTRATION SYSTEM OPERATIONAL NOTES:
1. THE PRIMARY EXISTING FILTRATION SYSTEM COMPONENTS SHALL REMAIN, INCLUDING FILTER, CHEMICAL SYSTEM, AND HEATER. THESE
ARE DESIGNED FOR A 450 GPM FLOW RATE.
2. EXISTING SAND FILTER HAS A 30 SF SURFACE AREA AND IS CAPABLE OF A 450 GPM FLOW AT A FILTRATION RATE OF 15 GPM/SF. BOTH NEW PUMPS SCHEDULED ON PL400.E ARE SIZED FOR THIS MAXIMUM 450 GPM FLOW RATE, BUT THE FILTRATION SYSTEM DESIGN FLOW
RATE IS 274 GPM AS DESCRIBED IN NOTE 3 BELOW.
3. THE MINIMUM TURNOVER FOR AN IWF (PER 2023 FBC SECTION 454.1.9.8.6.1) IS 30 MINUTES, RESULTING IN A MINIMUM ALLOWABLE FLOW RATE OF 137 GPM FOR THE NEW FILTRATION SYSTEM. THE DESIGN FLOW RATE IS 274 GPM USING A 15-MINUTE TURNOVER. CONTRACTOR SHALL ENSURE THE SYSTEM IS CAPABLE OF OPERATING AT THE DESIGN FLOW RATE. THE OWNER MAY OPERATE THE SYSTEM WITHIN THE RANGE OF THE MINIMUM ALLOWABLE FLOW RATE (137 GPM) AND THE DESIGN FLOW RATE (274 GPM).
4. SEE PL400.E FOR TWO NEW SPECIFIED PUMPS. PUMP P1E IS PRIMARY AND P2E IS A SECONDARY REDUNDANT PUMP. IT IS THE DESIGN INTENT TO RUN ONE PUMP AT A TIME FOR SUPPLY OF BOTH THE FILTRATION SYSTEM AND THE IWF ACTIVITIES. THE DESIGN FILTRATION FLOW RATE (274 GPM) PLUS THE ACTIVITY FLOW RATE (80 GPM) YIELDS A TOTAL OF 354 GPM. A VFD WILL BE USED TO REDUCE THE FLOW
FROM THE 450 GPM PUMP/FILTER CAPACITY TO THE 354 GPM DESIGN FLOW.
5. THE TWO SPECIFIED PUMPS ARE OVERSIZED INTENTIONALLY PER OWNER’S REQUEST AND MATCH PUMP MODELS INSTALLED ON THEIR OTHER SYSTEMS. THE EXCESS FLOW RATE PROVIDES AN OPPORTUNITY IN THE FUTURE TO ADD FEATURES TO THE IWF PAD WITHOUT A
PUMP OR FILTRATION SYSTEM CHANGE.
TOP VIEW
1' - 4 1/2" 1 3/4"
7 1/2"
1' - 4 1/2"
FRONT VIEW SIDE VIEW FRONT VIEW SIDE VIEW
HANDRAIL IN RETRACTED POSITION HANDRAIL IN EXTENDED POSITION
KEYED NOTES:
1. LADDERS WITH PULL-UP HANDRAIL, AVAILABLE IN 5 RUNG THROUGH 25 RUNG.
2. POLYPROPYLENE CONFORMS TO ASTM D-4101. LADDERS MEET ALL ASTM C-497 LOAD
REQUIREMENTS & OSHA 1910.26 & 1910.27 SPECIFICATIONS.
3. FASTEN LADDER TO FLOOR & WALL WITH 1/2" DIAMETER STAINLESS STEEL HILTI KWIK BOLT TZ
ANCHORS WITH 3 1/4" EMBEDMENT. ANCHORS TO BE INSTALLED PER MANUFACTURERS
INSTRUCTIONS.
4. STANDARD ADJUSTABLE MOUNTING BRACKET - 8" OD
5. ALUMINUM REINFORCED COPOLYMER POLYPROPYLENE RAIL 1-3/4" x 1-3/4" DIA
6. STEEL REINFORCED COPOLYMER POLYPROPYLENE RUNG 1-5/8" x 1-1/4" DIA WITH MOLDED
FINGER GRIPS, 12" CC
7. ALUMINUM & STEEL REINFORCED COPOLYMER POLYPROPYLENE PULL-UP HANDRAIL. LADDER
MANUFACTURED BY LANE INTERNATIONAL CORPORATION, P.O. BOX 925, TUALATIN, OREGON
800-666-0076
7 7
3 3
3 3 3
5 5
8" 8"
12' - 0"
TANK LID TOC
17.23'
TANK FLOOR TOC
10.23'
PL131.E
1' - 0"
SURGE TANK DRAIN SUMP
16.00'
OPERATING WATER LEVEL
13.23'
ADJACENT GRADE
15.51' @ DRAINS
IWF FFE & OVERFLOW
POOL WALL BACKFILL, TYP
SEE /4 PL201.E
POOL BASE, TYP
SEE /5 PL201.E
FOR STRUCTURAL
REINFORCING,
SEE /1 PL201.E
PL131.E
ACTIVITIES OFF; B/O SUMP
14.05'
12' - 0"
TANK LID TOC
17.23'
TANK FLOOR TOC
10.23'
16.00'
OPERATING WATER LEVEL
13.23'
ADJACENT GRADE
15.51' @ DRAINS
IWF FFE & OVERFLOW
POOL WALL BACKFILL, TYP
SEE /4 PL201.E
POOL BASE, TYP
SEE /5 PL201.E
FOR STRUCTURAL
REINFORCING,
SEE /2 PL201.E
ACTIVITIES OFF; B/O SUMP
14.05'
IWF PERIMETER
16.33'
POOL BASE, TYP
F08
F05
F02 F03F02
EXISTING SEAT WALL
EXISTING SEAT WALL
28' - 2 1/4" 3' - 7 1/2" SEE /5 PL201.E
EXISTING DECK OUTSIDE IWF
PAD IS EXISTING TO REMAIN
EXISTING DECK OUTSIDE IWD
PAD IS EXISTING TO REMAIN
NOTES:
1. FOR COMPLETE INSTALL DETAILS REFER TO WATERPLAY ASSEMBLY DOCUMENTS.
FEATURE ANCHOR ASSEMBLY,
REFER TO MANUFACTURER
INSTALLATION INFORMATION
SECTION VIEW
FOR STRUCTURAL
REINFORCING;
CONCRETE LEVELING PAD
FINISH; SEE NOTE ON PL130.E FOR
BASE BID MATERIAL & ALTERNATE OPTION
SEE /6 PL201.E
NOTES:
1. FOR COMPLETE INSTALL DETAILS REFER TO WATERPLAY ASSEMBLY DOCUMENTS.
SECTION VIEW
FINISH; SEE NOTE ON PL130.E FOR
BASE BID MATERIAL & ALTERNATE OPTION
CONCRETE LEVELING PAD
FEATURE ANCHOR ASSEMBLY,
REFER TO MANUFACTURER
INSTALLATION INFORMATION
FOR STRUCTURAL
REINFORCING;
SEE /- ---
3' - 0"
RED VINYL GRIP
AUTOMATIC HOLD OPEN ARM
LIFT MECHANISM HOUSING
NOTES:
1. FLOOR ACCESS DOOR, SIZE 36" X 36" AS MANUFACTURED BY BILCO (TYPE TER) OR APPROVED EQUAL.
2. PROVIDED WITH 1" FILLABLE PAN TO RECEIVE FILL MATERIAL.
3. FRAME SHALL BE 1/4" EXTRUDED ALUMINUM WITH BUILT-IN NEOPRENE CUSHION AND CONTINUOUS ANCHOR FLANGE.
4. DOOR SHALL BE 1/4" ALUMINUM PLATE REINFORCED WITH ALUMINUM STIFFENERS AS REQUIRED.
5. CAST STEEL HINGES SHALL BE BOLTED TO UNDERSIDE AND PIVOT ON TORSION BARS THAT COUNTERBALANCE THE
DOOR FOR EASY OPERATION.
6. DOOR SHALL OPEN 90 DEGREES AND LOCK AUTOMATICALLY IN THAT POSITION. A VINYL GRIP HANDLE SHALL BE
PROVIDED TO RELEASE THE COVER FOR CLOSING.
7. DOOR SHALL BE BUILT TO WITHSTAND A LIVE LOAD OF 150 PSF AND EQUIPPED WITH A SLAM LOCK THAT REQUIRES A
REMOVABLE SQUARE KEY WRENCH/HANDLE TO OPEN THE DOOR. A PLUG IS POSITIONED OVER THE SLAM LOCK HOLE
TO PREVENT DEBRIS FROM ENTERING.
8. IN APPLICATIONS WHERE VEHICLES MAY BE DRIVING OVER THE HATCH, DOOR SHALL BE BUILT TO WITHSTAND A LIVE
LOAD OF 300 PSF (NYSTROM MODEL FDPPA ONLY).
9. ALUMINUM SHALL BE MILL FINISH WITH BITUMINOUS COATING TO BE APPLIED TO EXTERIOR OF FRAME BY
MANUFACTURER.
10. HARDWARE SHALL BE SS.
11. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
12. MANUFACTURER SHALL GUARANTEE AGAINST DEFECTS IN MATERIAL OR WORKMANSHIP FOR A PERIOD OF FIVE
YEARS.
SLAM LOCK
4"
1" DEEP PAN COVER
CONTINUOUS ALUMINUM STEEL
HINGE
/2
World Leaders in Aquatic Planning, Design and Engineering
100 Park Avenue | Beaver Dam, WI 53916 t 920.887.7375 This Document and the ideas, renderings and other contents contained therein are the sole property of Water Technology, Inc. and may not be disseminated, copied, reproduced or otherwise used without prior written consent of Water Technology, Inc.
DRAWINGS MUST BE
VIEWED AND PLOTTED
IN FULL COLOR.
PROJECT PHASE:
S U
N -N
-F U
N L
A G
O O
N
R E
N O
V A
T
IO
N S
L iv in g st o n
R d
N a p le s, F L
PL131.E
POOL E - IWF SECTION AND DETAILS
ISSUE DATE: 11/08/2024
PROJECT NUMBER: 22567
DRAWN BY: TJT
CHECKED BY: RIG
100% CONSTRUCTION DOCUMENTS
DETAIL VIEW
NONE
PL131.E
5 ACCESS LADDER
SECTION VIEW
3/4" = 1'-0"
PL131.E
2 POOL E - IWF SURGE TANK
SECTION VIEW
3/4" = 1'-0"
PL131.E
3 IWF COLLECTOR TANK
SECTION VIEW
3/8" = 1'-0"
PL131.E
1 POOL E - IWF
REVISION SCHEDULE
Number Description Date
DETAIL VIEW
1 1/2" = 1'-0"
PL131.E
6 ACTIVITY INSTALLATION - WATERPLAY PLAYPHASE BASE
DETAIL VIEW
1 1/2" = 1'-0"
PL131.E
7 ACTIVITY INSTALLATION - WATERPLAY GROUND SPRAY BASE
DETAIL VIEW
NONE
PL131.E
4 ACCESS HATCH
1A
PL132.E
F04
PL131.E
/4
F04
2A
PL132.E
F05
PL131.E
/4
F05
5A
PL132.E
F06
PL131.E
/4
F06
4A
PL132.E
F07
PL131.E
/4
F07
3A
PL132.E
F08
PL131.E
PL131.E
/2
/4
F08
6A
PL132.E
F09
PL131.E
/4
F09
World Leaders in Aquatic Planning, Design and Engineering
100 Park Avenue | Beaver Dam, WI 53916 t 920.887.7375 This Document and the ideas, renderings and other contents contained therein are the sole property of Water Technology, Inc. and may not be disseminated, copied, reproduced or otherwise used without prior written consent of Water Technology, Inc.
DRAWINGS MUST BE
VIEWED AND PLOTTED
IN FULL COLOR.
PROJECT PHASE:
S U
N -N
-F U
N L
A G
O O
N
R E
N O
V A
T
IO
N S
L iv in g st o n
R d
N a p le s, F L
PL132.E
POOL E - IWF DETAILS
ISSUE DATE: 11/08/2024
PROJECT NUMBER: 22567
DRAWN BY: TJT
CHECKED BY: RIG
100% CONSTRUCTION DOCUMENTS
PLAN VIEW
1/2" = 1'-0"
PL132.E
1 MAGNIF-EYE
SECTION VIEW
1/2" = 1'-0"
PL132.E
1A MAGNIF-EYE
PLAN VIEW
1/2" = 1'-0"
PL132.E
2 SHARK
PLAN VIEW
1/2" = 1'-0"
PL132.E
2A SHARK
PLAN VIEW
1/2" = 1'-0"
PL132.E
5 CROW'S NEST
SECTION VIEW
1/2" = 1'-0"
PL132.E
5A CROW'S NEST
PLAN VIEW
1/2" = 1'-0"
PL132.E
4 WHALE TAIL
SECTION VIEW
1/2" = 1'-0"
PL132.E
4A WHALE TAIL
PLAN VIEW
1/2" = 1'-0"
PL132.E
3 OGOPOGO
SECTION VIEW
1/2" = 1'-0"
PL132.E
3A OGOPOGO
PLAN VIEW
1/2" = 1'-0"
PL132.E
6 CARRONADE CANNON
SECTION VIEW
1/2" = 1'-0"
PL132.E
6A CARRONADE CANNON
Project Number: 2024-2000.13 Phone 920 / 592 9440
PL201.E
PL201.E
SEE /6 PL201.E
SEE /6 PL201.E
SEE /7 PL201.E
PL201.E
N
PL201.E
OPENING FOR HATCH,
SEE . REINFORCE
PER , TOP AND
BOTTOM.
/4 PL200.E
TYPICAL
PL201.E
TYPICAL
/4 PL131.E
DESIGN IS IN ACCORDANCE WITH THE 2023 FLORIDA BUILDING CODE, 8TH EDITION AS AMENDED TO DATE.
STRUCTURAL DRAWINGS AND POOL DRAWINGS MUST BE USED IN CONJUNCTION WITH EACH OTHER.
POOL DRAWINGS DICTATE ALL FINAL CONDITIONS OF POOL, FEATURES, AND DIMENSIONS OF POOL SHELL, INCLUDING POOL FINISH. UNLESS OTHERWISE INDICATED, STRUCTURAL DIMENSIONS ARE CONCRETE TO CONCRETE, AND DICTATE REQUIRED THICKNESSES FOR STRUCTURAL INTEGRITY ONLY.
ASSUMED SOIL PARAMETERS FOR POOL STRUCTURAL DESIGN
1. POOL DESIGNED FOR THE EMPTY AND FULL CONDITIONS
2. IF ANY OF THE CRITERIA LISTED BELOW ARE NOT MET THEN THE POOL’S STRUCTURAL DESIGN
SHOULD BE RE-EVALUATED BY THE POOL STRUCTURAL ENGINEER.
• SOIL BEARING CAPACITY 1,500 PSF MINIMUM
• AT-REST EQUIVALENT FLUID PRESSURE 55 PSF/FT MAXIMUM (DRAINED)
• GROUNDWATER TABLE ELEVATION AT GROUND SURFACE
• SETTLEMENT AND/OR PVR DOES NOT EXCEED 1/2" TOTAL MOVEMENT AND
1/4" DIFFERENTIAL MOVEMENT
STRUCTURAL NOTES
1. REINFORCEMENT AT WALL CORNERS AND WALL BENDS SHALL BE DETAILED PER THE
ASSOCIATED TYPICAL DETAILS. CORNER AND BEND BARS SHALL BE THE SAME SIZE AND SPACING
AS THE TYPICAL HORIZONTAL WALL REINFORCING OF THE ASSOCIATED WALLS.
2. UNLESS OTHERWISE INDICATED, ALL WALL REINFORCEMENT BARS SHALL BE CONTINUOUS
AROUND CORNERS. REINFORCEMENT SHALL BE EXTENDED INTO CONNECTING WALLS. UNLESS
OTHERWISE INDICATED, CONTRACTOR MAY SPLICE CONTINUOUS SLAB BARS AT LOCATIONS OF
THEIR CHOOSING, EXCEPT THAT TOP BAR SPLICES SHALL BE LOCATED AT MID-SPAN AND BOTTOM BAR SPLICES SHALL BE LOCATED AT SUPPORTS. ALL REINFORCEMENT BENDS AND LAPS, UNLESS
OTHERWISE INDICATED, SHALL SATISFY THE MINIMUM REQUIREMENTS FOR CLASS B SPLICES.
3. FOR REINFORCEMENT AT WALL OR FLOOR SLAB PENETRATIONS, SEE
4. MINIMUM POURED CONCRETE DESIGN STRENGTH = 4500 PSI, MINIMUM SHOTCRETE DESIGN
STRENGTH = 5000 PSI
5. ALL NEW SPRAY PAD CONCRETE SHALL CONTAIN SHRINKAGE REDUCING ADMIXTURE. (NOT
REQUIRED FOR TANK.)
REINFORCEMENT NOTES: 60KSI, A615, DEFORMED BARS
1. REINFORCEMENT SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH ACI "MANUAL OF
CONCRETE PRACTICE", LATEST EDITION, UNLESS OTHERWISE NOTED.
2. ALL LAPS SHALL BE CLASS "B" PER ACI 318 UNLESS OTHERWISE NOTES ON THE DESIGN
DRAWINGS OR UNLESS THE DETAILER TAKES SPECIAL CARE TO PROVIDE STAGGERED LAPS. USE
TOP BAR LAP LENGTHS FOR ALL HORIZONTAL WALL BARS AND FOR TOP BARS IN SLABS AND
BEAMS OVER 14" DEEP
3. LAP LENGTH SHALL BE SPECIFICALLY NOTED ON PLACING DRAWINGS WHERE MORE THAN ONE
BAR MAKES UP A CONTINUOUS STRING.
4. TIE POOL REINFORCING STEEL WITH 18-GAUGE ANNEALED WIRE AS SPECIFIED IN THE CRSI 63
RECOMMENDED PRACTICE FOR PLACING REINFORCING BARS. ALL TIE WIRES SHALL BE "MADE
TIGHT" FOR ELECTRICAL BONDING PURPOSES, AS REQUIRED PER .
5. ALL HOOKS SHALL BE STANDARD HOOKS UNLESS NOTED OTHERWISE.
REINFORCING STEEL MINIMUM CLEAR COVER REQUIREMENTS
COORDINATE WITH REINFORCEMENT STEEL PLACING REQUIREMENTS
3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH
2" TYPICAL ALL ELSE, UNLESS NOTED OTHERWISE ON DETAILS
REINFORCEMENT CLASS "B" LAP LENGTHS
BASED UPON 4500 PSI CONCRETE AND 60 KSI REINFORCING STEEL
/4 PL200.E
NOTE
STRUCTURAL AND REINFORCEMENT NOTES
TYPICAL STANDARD DETAIL
/2 PL130.E
GEOTECHNICAL PARAMETERS
ADD (1) #5 x 4'-0" DIAGONAL
AT EACH CORNER FOR EACH
LAYER OF REINFORCING.
EXTEND ADDITIONAL
REINFORCEMENT PAST
OPENING BY 2D, 2W OR 2L AS
INDICATED (2'-0" MINIMUM)
STEEL
REINFORCING
CUT BAND "B"
S T
E E
L
R
IN
F
O R
C
IN
G
C U
T B
A N
D
A
AREA OF BARS AT
EACH SIDE EQUAL TO
BAND OF BARS CUT
NOTES:
1. TYPICAL FOR ALL OPENINGS IN CONCRETE WALLS AND SLABS INCLUDING DRAINS UNLESS INDICATED OTHERWISE ON PLANS.
2. DO NOT WELD REINFORCEMENT TO PIPE SLEEVES AND INSERTS.
3. ALL OPENINGS THROUGH WATERTIGHT TANK REQUIRE WATERSTOPS.
4. PROVIDE MINIMUM LAP AS NOTED OR SHOWN ON PLANS (TYPICAL).
S T
E
IN
F
O R
C
T B
A N
D
A
STEEL
REINFORCING
CUT BAND "B"
S T
E
IN
F
O R
C
T B
A N
D
A
STEEL
REINFORCING
CUT BAND "B"
STEEL
REINFORCING
CUT BAND "B"
D D 2
L L
W 2W
NOTES:
1. DETAIL IS SCHEMATIC AND INDICATES CLEARANCES AND INSTALLATION INFORMATION ONLY.
FOR APPLICABLE INSTALLATION LOCATIONS SEE POOL STRUCTURAL DETAILS.
2. WATERSTOP SHALL BE 6" PVC RIBBED WITH 1" DIA CENTERBULB UNLESS NOTED OTHERWISE.
3. INSTALL WATERSTOP ON WET SIDE(S) OF REINFORCEMENT.
4. ALL WATERSTOPS SHALL BE WELDED PER MANUFACTURER'S REQUIREMENTS.
5. SPACING BETWEEN REINFORCING STEEL AND WATERSTOP SHALL BE NO LESS THAN 1.5 x DIA
OF THE LARGEST AGGREGATE IN THE APPROVED CONCRETE MIX.
6. SEE SPECIFICATION SECTION 131120 FOR ADDITIONAL WATERSTOP REQUIREMENTS.
FLOOR / WALL JOINT
SECOND POUR
FIRST POUR
MIN
2"
PVC WATERSTOP
POOL WATER
TYPICAL
REINFORCEMENT
TYPICAL
REINFORCEMENT
MIN
1 1/2"
NOTE:
1. DETAIL IS SCHEMATIC AND INDICATES CLEARANCES AND INSTALLATION INFORMATION ONLY. FOR APPLICABLE INSTALLATION LOCATIONS SEE POOL
STRUCTURAL DETAILS.
2. BASIS OF DESIGN IS TYPE KBA-1510FP WATERSTOP BY ADEKA. SUBSTITUTIONS MUST BE APPROVED BY ENGINEER. NOTE THAT CLEARANCES FOR
SUBSTITUTIONS MAY DIFFER. REFER TO MANUFACTURER REQUIREMENTS.
3. INSTALL WATERSTOP ON WET SIDE(S) OF REINFORCEMENT.
4. DIMENSION ABOVE IS A MIN FOR CONCRETE COVERAGE AND DOES NOT INCLUDE THE POOL FINISH. PROVIDE ADDITIONAL CONCRETE COVERAGE IF POSSIBLE.
5. PROTECT WATERSTOP FROM WATER, DIRT, DEBRIS, AND DAMAGE PRIOR TO COVERING WITH CONCRETE.
6. SEE SPECIFICATION SECTION 131120 FOR ADDITIONAL WATERSTOP REQUIREMENTS.
SECTION B-B FLOOR / WALL JOINT SECTION A-A: WALL / WALL JOINT OR FLOOR/FLOOR JOINT
SECOND POUR
FIRST POUR
TYPICAL
REINFORCEMENT
MIN
1"
WATERSTOP WITH
BUTYL TAPE
ADHESIVE
NON-MOVING JOINT
TYPICAL POOL FLOOR
T Y
P
IC
A L P
O O
L W
A L L
TYPICAL POOL WALL
M
IN1
POOL WATER
POOL WATER
TYPICAL
REINFORCEMENT
World Leaders in Aquatic Planning, Design and Engineering
100 Park Avenue | Beaver Dam, WI 53916 t 920.887.7375 This Document and the ideas, renderings and other contents contained therein are the sole property of Water Technology, Inc. and may not be disseminated, copied, reproduced or otherwise used without prior written consent of Water Technology, Inc.
DRAWINGS MUST BE
VIEWED AND PLOTTED
IN FULL COLOR.
PROJECT PHASE:
S U
N -N
-F U
N L
A G
O O
N
R E
N O
V A
T
IO
N S
L iv in g st o n
R d
N a p le s, F L
PL200.E
STRUCTURAL NOTES, PLAN(S) AND
SCHEDULE
ISSUE DATE: 11/08/2024
PROJECT NUMBER: 22567
DRAWN BY: AMZ
CHECKED BY: SAC
100% CONSTRUCTION DOCUMENTS
PLAN VIEW
1/8" = 1'-0"
PL200.E
1 POOL E - IWF STRUCTURAL
NOT TO SCALE
DETAIL VIEWPL200.E
4 REINFORCING - REINFORCEMENT AT OPENINGS
NOT TO SCALE
DETAIL VIEWPL200.E
3 WATERSTOP - PVC
NOT TO SCALE
DETAIL VIEWPL200.E
2 WATERSTOP - COMPRESSIBLE NON-MOVING JOINT - ADEKA
6"1' - 0"12' - 0"1' - 0"6"
COMPRESSIBLE
WATERSTOP, TYPICAL,
#4@12" OC
#4@8" OC
DOWELS TO MATCH SIZE
AND SPACING OF VERTICAL
REINFORCING, TYPICAL
PVC WATERSTOP, TYPICAL,
TANK CONCRETE SHALL CONTAIN
CRYSTALLINE WATERPROOFING
ADDITIVE PER SPECIFICATIONS.
#4@12" OC
#4@8" OC
#4@12" OC EW, TOP#4@12" OC EW, TOP
#4@6" OC#4@6" OC
/2 PL200.E
/3 PL200.E
/4 PL201.E/4 PL201.E
/5 PL201.E
#4@6" OC EW, BOTTOM#4@6" OC EW, BOTTOM
TANK LID TOC
17.23'
#4@6" OC#4@6" OC
1' - 0" SQ
6"1' - 0"12' - 0"1' - 0"6"
COMPRESSIBLE
WATERSTOP, TYPICAL,
DOWELS TO MATCH SIZE
AND SPACING OF VERTICAL
REINFORCING, TYPICAL
PVC WATERSTOP, TYPICAL,
TANK CONCRETE SHALL CONTAIN
CRYSTALLINE WATERPROOFING
ADDITIVE PER SPECIFICATIONS.
/2 PL200.E
/3 PL200.E
/5 PL201.E
/4 PL201.E/4 PL201.E #4@12" OC
#4@8" OC
#4@12" OC
#4@8" OC
#4@12" OC EW, TOP#4@12" OC EW, TOP
#4@6" OC#4@6" OC
#4@6" OC EW, BOTTOM#4@6" OC EW, BOTTOM
TANK LID TOC
17.23'
Project Number: 2024-2000.13 Phone 920 / 592 9440
90 DEGREE HOOK
CORNER BAR SAME
SIZE AND SPACING AS
HORIZONTAL BARS
WITH CLASS "B" LAP
BETWEEN BARS
/4 PL200.E
C L E
A R
C O
V E
R
2" THICK x 16" SQUARE LEVELING PAD.
PROVIDE PER MANUFACTURER'S
REQUIREMENTS.
FEATURE ANCHOR ASSEMBLY, SEE PL131.E AND PL132.E FOR
MORE INFORMATION. APPEARANCE OF FEATURE ASSEMBLY
MAY VARY FROM WHAT IS SHOWN. REFER TO
MANUFACTURER'S DOCUMENTS FOR MORE INFORMATION
ADJUST REINFORCING AT
OPENING IN SLAB AS REQUIRED,
TYPICAL, SEE
M
IN
C O
V E
R
C
L E
A R
#5@12" OC TOP
AND BOTTOM EW
#5@12" OC TOP
AND BOTTOM EW
VAPOR BARRIER
TOP OF FINISHED SURFACE
ASTM D2487 CLASS 1A
AGGREGATE: 3/4"-1" CLEAR,
ANGULAR. PLACE IN 6"
MAXIMUM LIFTS
TANK WALL
1' - 0" MIN
MIRAFI 140N: NONWOVEN
POLYPROPYLENE GEOTEXTILE
BARRIER, 4.8 OZ/YD2, BY TENCATE
GEOSYNTHETICS. PLACE BARRIER
AROUND ENTIRE TANK
C L E
A R
C O
V E
R
E Q
E Q
VAPOR BARRIER, LAP WITH
EXISTING PER MANUFACTURER'S
RECOMMENDATIONS
MINIMUM 6" THICK
GRANULAR BASE. MATCH
EXISTING IF THICKER.
#5@12" OC TOP
AND BOTTOM EW
#5@12" OC TOP
AND BOTTOM EW
#4@8” OC, DRILL AND EPOXY
INTO EXISTING CONCRETE
(6” MINIMUM EMBEDMENT)
MATCH EXISTING CONCRETE
FINISH ON ALL NEW CONCRETE
NOTES:
1. SCARIFY CONCRETE INTERFACE AND APPLY BONDING AGENT.
2. NEW CONCRETE SHALL CONTAIN SHRINKAGE REDUCING ADMIXTURE AND
SHALL BE WET CURED PER SPECIFICATIONS.
3. CONTRACTOR TO MAINTAIN STABLE BASE BELOW EXISTING SLAB.
PROTECTION OF THE SUBGRADE, AND/OR UNDERPINNING MAY BE REQUIRED.
TYPICAL
CLASS B SPLICE,
C L E
A R
C O
V E
R
6" M
IN
EXISTING POOL BASE,
FIELD VERIFY
EXISTING VAPOR
BARRIER
M
IN
TOP OF FINISHED SURFACE
M
IN
TANK FLOOR SLAB, TYPICAL
ASTM D2487 CLASS 1A AGGREGATE: 3/4"-1"
CLEAR, ANGULAR. PLACE IN 6" MAXIMUM LIFTS
4" PERFORATED DRAIN TILE
WRAPPED WITH GEOTEXTILE FABRIC.
SEE PIPING SHEETS.
MIRAFI 140N: NONWOVEN POLYPROPYLENE
GEOTEXTILE BARRIER, 4.8 OZ/YD2, BY
TENCATE GEOSYNTHETICS. PLACE BARRIER
UNDER ENTIRE TANK, BY POOL CONTRACTOR
NATIVE GRANULAR MATERIAL OR
STRUCTURAL FILL PER GEOTECHNICAL
ENGINEER'S RECOMMENDATIONS
BY POOL
CONTRACTOR
BY SITE
CONTRACTOR
#4@8" OC
TYP POOL FLOOR
REINFORCING
#4@8" OC
CONTINUOUS COMPRESSIBLE
WATERSTOP AROUND ALL
PENETRATIONS, TYPICAL,
TYP POOL FLOOR
REINFORCING
/2 PL200.E
VAPOR BARRIER, LAP
WITH EXISTING PER
MANUFACTURER'S
RECOMMENDATIONS
MINIMUM 6" THICK
GRANULAR BASE. MATCH
EXISTING IF THICKER.
TOP OF FINISHED SURFACE
M
IN6
1' - 6" SQUARE
TYPICAL
8"
CONTRACTOR TO
COORDINATE GRATING
WIDTH/DEPTH PRIOR TO
CONSTRUCTION
/2
CL CANISTER
BASE
3" MINIMUM THICK RECTANGULAR
LEVELING PAD. PROVIDE PER
MANUFACTURER'S REQUIREMENTS
/4 PL200.E
C L E
A R
C O
V E
R
FEATURE ANCHOR ASSEMBLY, SEE PL131.E AND PL132.E FOR
MORE INFORMATION. APPEARANCE OF FEATURE ASSEMBLY
MAY VARY FROM WHAT IS SHOWN. REFER TO
MANUFACTURER'S DOCUMENTS FOR MORE INFORMATION
ADJUST REINFORCING AT
OPENING IN SLAB AS REQUIRED,
TYPICAL, SEE
M
IN
C O
V E
R
C
L E
A R
#5@12" OC TOP
AND BOTTOM EW
#5@12" OC TOP
AND BOTTOM EW
TOP OF FINISHED SURFACE
World Leaders in Aquatic Planning, Design and Engineering
100 Park Avenue | Beaver Dam, WI 53916 t 920.887.7375 This Document and the ideas, renderings and other contents contained therein are the sole property of Water Technology, Inc. and may not be disseminated, copied, reproduced or otherwise used without prior written consent of Water Technology, Inc.
DRAWINGS MUST BE
VIEWED AND PLOTTED
IN FULL COLOR.
PROJECT PHASE:
S U
N -N
-F U
N L
A G
O O
N
R E
N O
V A
T
IO
N S
L iv in g st o n
R d
N a p le s, F L
PL201.E
POOL E - STRUCTURAL DETAILS
ISSUE DATE: 11/08/2024
PROJECT NUMBER: 22567
DRAWN BY: AMZ
CHECKED BY: SAC
100% CONSTRUCTION DOCUMENTS
SECTION VIEW
3/4" = 1'-0"
PL201.E
1 REINFORCING - POOL E - IWF SURGE TANK
SECTION VIEW
3/4" = 1'-0"
PL201.E
2 REINFORCING - POOL E - IWF SURGE TANK
NOT TO SCALE
DETAIL VIEWPL201.E
3 REINFORCING - DOUBLE MAT REINFORCING AT CORNER
NOT TO SCALE
DETAIL VIEWPL201.E
6 REINFORCING - ACTIVITY INSTALLATION LEVELING FOOTING - SMALL / MEDIUM PLAYPHASE
NOT TO SCALE
DETAIL VIEWPL201.E
4 POOL WALL BACKFILL
REVISION SCHEDULE
Number Description Date
NOT TO SCALE
DETAIL VIEWPL201.E
8 REINFORCING - EXISTING TO NEW SLAB
NOT TO SCALE
DETAIL VIEWPL201.E
5 FLOOR SUB BASE UNDERDRAIN
NOT TO SCALE
DETAIL VIEWPL201.E
9 REINFORCING - FLOOR OUTLET
NOT TO SCALE
DETAIL VIEWPL201.E
7 REINFORCING - ACTIVITY INSTALLATION LEVELING FOOTING - GROUNDSPRAY
-36" -36"-36"
-42" -42" -42"
-42" -42" -42"
S P E A R S
S P E A R S
S P
EA
R S
S P
EAR
S
R Y
E N T
N O
RY
E
NT
N O
RY ENT NO RY ENT NO RY ENT NO
RY
E
NT
NO
R Y
E N T
N O
R Y
E N T
N O
RYENTNORYENTNORYENTNO
RY
E
NT
NO
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-36"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-36"
-30"
-30"
-30"
-30"
-30"
-30"
-30"
-42"
-42"
-42"
-42"
-42"
-36"
-42"
-42"
-42"
-42"
-42"
POOL E - IWF SPRAY PAD
SEE PL330.E
POOL D - PLUNGE POOL
SEE "D" SHEET PACKAGE
FOR ALL DRAWINGS
POOL C - LAZY RIVER SEE "C"
SHEET PACKAGE FOR ALL
DRAWINGS
PB1 MECHANICAL ROOM
SEE PL400.E
N
EXISTING PIPING FROM
MECHANICAL ROOM IS
NOT SHOWN. EXACT
ROUTING IS UNKNOWN.
World Leaders in Aquatic Planning, Design and Engineering
100 Park Avenue | Beaver Dam, WI 53916 t 920.887.7375 This Document and the ideas, renderings and other contents contained therein are the sole property of Water Technology, Inc. and may not be disseminated, copied, reproduced or otherwise used without prior written consent of Water Technology, Inc.
DRAWINGS MUST BE
VIEWED AND PLOTTED
IN FULL COLOR.
PROJECT PHASE:
S U
N -N
-F U
N L
A G
O O
N
R E
N O
V A
T
IO
N S
L iv in g st o n
R d
N a p le s, F L
PL300.E
OVERALL PIPING PLAN
ISSUE DATE: 11/08/2024
PROJECT NUMBER: 22567
DRAWN BY: BRE
CHECKED BY: Checker
100% CONSTRUCTION DOCUMENTS
PLAN VIEW
1" = 30'-0"
PL300.E
1 OVERALL PIPING PLAN
KEY NOTES:
1. SUBGRADE: MINIMIZE DISTURBANCE OF EXISTING SOILS ON SIDES AND BELOW PIPE TRENCH
DURING EXCAVATION. CLEAR SUBGRADE OF LARGE STONES & ORGANIC MATERIALS.
2. SUBBASE MATERIALS: REQUIRED ONLY IF EXISTING SUBGRADE CONTAINS UNSUITABLE SOILS
AND/OR DOES NOT MEET THE REQUIREMENTS OF THE GEOTECHNICAL REPORT FOR UTILITY
TRENCHES.
3. EMBEDMENT MATERIALS: ASTM D2487 CLASS 1A OR 1B AGGREGATE, 1.5" MAXIMUM SIZE.
4. BEDDING: MINIMUM 6 INCH THICK AGGREGATE LAYER.
5. HAUNCHING: PLACE AND COMPACT HAUNCHING MATERIALS UNDER AND AROUND PIPE/S UP TO
THE PIPE SPRINGLINE BY HAND TO ASSURE CONTINUOUS AND EFFECTIVE PIPE SUPPORT.
6. COVER: MINIMUM 6 INCHES ABOVE TOP OF PIPE.
7. POOL BEDDING COURSE/SUBBASE. SEE PL200 FOR REQUIREMENTS.
8. TRENCH WIDTH FOR EMBEDMENT MATERIALS: MINIMIZE WIDTH TO 6 - 12" BETWEEN TRENCH
WALL AND EDGE OF NEAREST PIPE. ALLOW 6" MINIMUM BETWEEN ADJACENT PIPE WALLS WHEN
PLACING MULTIPLE PIPES IN A COMMON TRENCH.
SUBBASE
BEDDING
HAUNCHING
EMBEDMENT MATERIAL
PIPE
COVER
PIPE ZONE
SPRINGLINE
OF PIPE
GENERAL NOTES:
A. SEE SPECIFICATIONS SECTION 13 11 20 FOR ADDITIONAL POOL PIPE TRENCH MATERIAL AND
INSTALLATION REQUIREMENTS.
B. PLACE ALL PIPE TRENCH MATERIALS IN 6" MAXIMUM LOOSE LIFTS.
SUBGRADE 1
EXCAVATED TRENCH
POOL FLOOR
KEY NOTES:
1. SUBGRADE: MINIMIZE DISTURBANCE OF EXISTING SOILS ON SIDES AND BELOW PIPE TRENCH
DURING EXCAVATION. CLEAR SUBGRADE OF LARGE STONES & ORGANIC MATERIALS.
2. SUBBASE MATERIALS: REQUIRED ONLY IF EXISTING SUBGRADE CONTAINS UNSUITABLE SOILS
AND/OR DOES NOT MEET THE REQUIREMENTS OF THE GEOTECHNICAL REPORT FOR UTILITY
TRENCHES.
3. EMBEDMENT MATERIALS: ASTM D2487 CLASS 1A OR 1B AGGREGATE, 1.5" MAXIMUM SIZE.
4. BEDDING: MINIMUM 6 INCH THICK AGGREGATE LAYER.
5. HAUNCHING: PLACE AND COMPACT HAUNCHING MATERIALS UNDER AND AROUND PIPE/S UP TO
THE PIPE SPRINGLINE BY HAND TO ASSURE CONTINUOUS AND EFFECTIVE PIPE SUPPORT.
6. COVER: MINIMUM 6 INCHES ABOVE TOP OF PIPE.
7. FINAL BACKFILL: USE ON-SITE EXISTING SOILS MEETING THE PROJECT GEOTECHNICAL REPORT
REQUIREMENTS FOR BACKFILL MATERIALS. DO NOT USE ORGANIC MATERIAL, CLAY, TOPSOIL,
OR OTHER DELETERIOUS SUBSTANCES. SLOPE TRENCH EXCAVATION IN FINAL BACKFILL ZONE
AS NEEDED.
8. TRENCH WIDTH FOR EMBEDMENT MATERIALS: MINIMIZE WIDTH TO 6" - 12" BETWEEN TRENCH
WALL AND EDGE OF NEAREST PIPE. ALLOW 6" MINIMUM BETWEEN ADJACENT PIPE WALLS WHEN
PLACING MULTIPLE PIPES IN A COMMON TRENCH.
9. FINAL GRADE MATERIALS: SEE RELATED PROJECT DRAWINGS AND SPECIFICATIONS FOR SOIL MATERIALS AND PLACEMENT REQUIREMENTS AT FINAL GRADE ELEVATIONS (E.G. DECK, CIVIL, LANDSCAPE, ETC. DRAWINGS).
SUBBASE
BEDDING
HAUNCHING
INITIAL BACK FILL
FINAL BACKFILL 7
EMBEDMENT MATERIAL
PIPE
COVER
PIPE ZONE
SPRINGLINE
OF PIPE
GENERAL NOTES:
A. SEE SPECIFICATIONS SECTION 13 11 20 FOR ADDITIONAL POOL PIPE TRENCH MATERIAL AND
INSTALLATION REQUIREMENTS.
B. PLACE ALL PIPE TRENCH MATERIALS IN 6" MAXIMUM LOOSE LIFTS.
C. COORDINATE WITH OTHER TRADES AS NEEDED TO ASSURE FOOTING/FOUNDATIONS ABOVE DO
NOT LOAD THE PIPES. MAINTAIN PROPER CLEARANCES TO PREVENT UNDERMINING OF
ADJACENT FOOTINGS/FOUNDATIONS.
SUBGRADE 1
M
IN
IM
U
M
EXCAVATED TRENCH
PIPING LEGEND
PIPE DESCRIPTION PIPE COLOR
AIR:
ACTIVITY SUPPLY:
CHEMICAL:
INLET SUPPLY:
GRAVITY:
JET SUPPLY:
PROPULSION SUPPLY:
AUTOFILL SENSOR:
SKIMMER SUCTION:
SLIDE SUPPLY:
SUCTION:
SURGE TANK STRUCTURE,
REFER TO TYP WALL DETAIL
GRADE
12" CAP
4" PERFORATED DRAIN TILE WRAPPED
WITH GEOTEXTILE FABRIC
SEE TYP POOL BASE DETAIL
18" x 18" MODEL #FD-8060 ALUMINUM
FLOOR DOOR WITH REINFORCED 1/4"
DIAMOND PLATE BY ACUDOR
INDUSTRIES TO BE LEVEL WITH
GRADE. PAINT FLOOR DOOR TO
MATCH SURROUNDING LANDSCAPING
12" SCH 40
PVC PIPE
EXTEND TANK LID CONCRETE OUT
TO FLOOR DOOR TO PROVIDE
SUPPORT FOR PIPE AND DOOR.
SEE /5 PL201.E
GENERAL POOL PIPING AND EQUIPMENT PLAN NOTES
PIPING
1. THE PIPING LAYOUTS ON THESE DRAWINGS ARE SCHEMATIC AND FOR REFERENCE ONLY. PIPING AS SHOWN IS SPREAD OUT FOR CLARITY. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING FINAL PIPE ROUTING AND ELEVATIONS.
2. REDUCE THE USE OF FITTINGS AND LONG PIPE RUNS TO MINIMIZE HEAD LOSS IN THE SYSTEM.
3. ALL OUTDOOR PIPING SHALL BE INSTALLED IN A PIPE TRENCH WITH BEDDING AND COVER MATERIALS PER SPECIFICATIONS.
PIPING MAY BE STACKED IN THE PIPE TRENCH.
4. ARROWS DENOTE DIRECTION OF FLOW.
5. REFER TO ALL DISCIPLINES DOCUMENTATION AND COORDINATE ALL PIPING AND EMBEDMENTS WITH AFFECTED TRADES.
6. ALL GRAVITY PIPING SHALL BE INSTALLED AT A MINIMUM SLOPE OF 1" DROP PER 10' LENGTH. ALL OUTDOOR PIPING SHALL BE
INSTALLED WITH A SLOPE TO ALLOW COMPLETE DRAINING. PROVIDE WINTERIZING/DRAINING INSTRUCTIONS AND SCHEMATICS
TO OWNER.
7. CONTRACTOR SHALL USE SWING JOINTS OR OTHER MEANS AND METHODS AS REQUIRED TO PROVIDE POOL INLET FITTINGS FLUSH AND PERPENDICULAR WITH THE POOL FLOOR AND AS REQUIRED FOR PROPER SLOPE TO DRAIN FOR WINTERIZATION.
8. ALL SUPPORTS, BRACING, FASTENERS AND HARDWARE IN THE SURGE TANK(S) SHALL BE STAINLESS STEEL.
9. THE INTENT OF THESE DRAWINGS IS NOT TO BE INCLUSIVE OF ALL VALVES OR FITTINGS REQUIRED FOR THIS PROJECT. IT IS
THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE ALL VALVES AND FITTINGS REQUIRED.
MECHANICAL SYMBOL
LEGEND
PUMP
PUMP WITH
INTEGRAL STRAINER
STRAINER
REGENERATIVE MEDIA
FILTER
HIGH RATE SAND
FILTER
(HORIZONTAL)
HIGH RATE SAND
FILTER (VERTICAL)
POOL HEATER
HEAT EXCHANGER
UV UNIT
CHEMICAL CONTROLLER
CHEMICAL FEED PUMP
PULSAR CHLORINE
FEEDER
PPG CHLORINE FEEDER
CO2 FEEDER
CHEMICAL STORAGE
TANK
CO2 STORAGE TANK
AUTO FILL
SURGE TANK
VENTILATION FAN
GEAR OPERATED
BUTTERFLY VALVE
LEVER OPERATED
BUTTERFLY VALVE
PNEUMATIC
BUTTERFLY
VALVE
TRUE UNION
BALL VALVE
TRUE UNION
CHECK VALVE
ELECTRONIC
MODULATING
VALVE
MODULATING
FLOAT VALVE
VENTURI
SOLENOID VALVE
CHECK VALVE
WYE STRAINER
CONCENTRIC REDUCER
ECCENTRIC REDUCER
FLANGED BREAK
COMPOUND GAUGE
THERMOMETER
PRESSURE RELIEF
VALVE
EXPANSION JOINT
FLOW SWITCH
FLOW METER (SENSOR)
G
M
S
FS
FM
PIPING NOTES
REFER TO DIVISION 13 SPECIFICATIONS FOR DETAILS
PIPING
A. ALL PIPING SHALL BE IN ACCORDANCE WITH THE STATE OF FLORIDA PLUMBING REGULATIONS, FLORIDA DEPARTMENT OF HEALTH, FLORIDA BUILDING CODE SECTION 454: SWIMMING POOLS AND BATHING PLACES, THE A.S.T.M. DESIGNATION
NUMBER D-1785, AND THE NSF SEAL FOR POTABLE WATER.
B. ALL PIPING DESIGNED FOR 6’/SECOND MAXIMUM SUCTION VELOCITY, 8’/SECOND MAXIMUM PRESSURE VELOCITY, AND
3’/SECOND MAXIMUM GRAVITY VELOCITY.
C. MAIN DRAIN PIPING AND GUTTER PIPING ARE DESIGNED TO CARRY MINIMUM 100% OF THE RECIRCULATION RATE.
D. ALL PIPING MUST BE LAID ON A GRADE SO IT WILL DRAIN COMPLETELY BY GRAVITY TO PREVENT DAMAGE DURING
FREEZING WEATHER. MAIN DRAIN LINE PIPING MUST BE LAID ON A GRADE SO THAT (A) ALL PIPING FROM BENEATH THE POOL TO THE ELEVATION CHANGE SHALL PITCH TO DRAIN TO THE POOL MAIN DRAIN SUMPS AND; (B) ALL PIPING FROM
THE ELEVATION CHANGE TO THE SURGE TANK SHALL PITCH TO DRAIN TO THE SURGE TANK.
E. CONTRACTOR SHALL PROVIDE OPERATION, FILLING, EMPTYING, WINTERIZATION, AND START-UP INSTRUCTIONS TO
OWNER.
F. ALL ELEVATIONS TO BE FIELD VERIFIED FOR PROPER PITCH AND DRAINAGE. PITCH TO BE APPROXIMATELY 1”/10’-0”.
G. POOL CONTRACTOR SHALL MAKE EVERY EFFORT TO MINIMIZE FITTING QUANTITY TO REDUCE TOTAL DYNAMIC HEAD.
H. ALL DRAWINGS ARE INTENDED FOR SCHEMATIC USE ONLY. FINAL LOCATIONS SHALL BE FIELD VERIFIED WITH ALL OTHER
TRADES, BY CONTRACTOR. CONTRACTOR SHALL COORDINATE ALL WORK WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL, STRUCTURAL, PLUMBING, AND CIVIL DRAWINGS.
DRAINS
A. FILTER DRAIN/BACKWASH LINE, AND SURGE TANK OVERFLOW LINE TO DISCHARGE TO SEWER WITH AN AIR GAP
COMPLIANT WITH LOCAL REQUIREMENTS.
GAUGES:
A. COMPOUND GAUGES TO BE INSTALLED ON ALL PUMP SUCTION AND DISCHARGE LINES.
VALVES:
A. PROVIDE GEAR-OPERATED SUBSURFACE BUTTERFLY VALVES WITH VALVE STEM EXTENSIONS FOR ALL POOL AND SURGE
TANK DRAIN LINES.
B. EACH VALVE SHALL HAVE A PERMANENT IDENTIFYING LABEL OR TAG ATTACHED TO IT. THE SEQUENCE OF OPERATION, BRIEFLY STATED, SHALL BE PROMINENTLY DISPLAYED.
FLOW METERS:
A. FLOW METERS SHALL BE PROVIDED IN THE FILTRATION PUMP DISCHARGE LINE, AS INDICATED ON THE DRAWINGS.
B. UNINTERRUPTED FLOW SHALL BE PROVIDED TO THE FLOWMETER BY INSTALLING THEM ON STRAIGHT LENGTHS OF PIPE
WITHOUT ANY VALVES, ELBOWS, OR OTHER SOURCES OF TURBULENCE WITHIN MINIMUM 10 PIPE DIAMETERS UPSTREAM AND 5 PIPE DIAMETERS DOWNSTREAM OF THE FLOW METERS OR INSTALL PER MANUFACTURER’S RECOMMENDATIONS.
C. MAIN FLOW METER SHALL BE USED TO MONITOR BACKWASH RATE UNLESS OTHERWISE INDICATED IN THE DESIGN
DRAWINGS.
NOTES:
1. DETAIL ILLUSTRATES COMPRESSIBLE WATERSTOP FOR PIPE PENETRATIONS THROUGH POOL
SHELL. SEE PIPING PLANS AND DETAILS FOR APPLICABLE INSTALLATION LOCATIONS.
2. BASIS OF DESIGN FOR 6" OD PIPES OR LARGER IS TYPE KBA-1510FP COMPRESSIBLE
WATERSTOP BY ADEKA. FOR PIPES SMALLER THAN 6" OD USE SYNKOFLEX FLEXIBLE
WATERSTOP. SUBSTITUTIONS MUST BE APPROVED BY ENGINEER.
3. DIMENSION ABOVE IS A MIN FOR CONCRETE COVERAGE AND DOES NOT INCLUDE THE POOL
FINISH. PROVIDE ADDITIONAL CONCRETE COVERAGE IF POSSIBLE.
4. PROTECT WATERSTOP FROM WATER, DIRT, DEBRIS, AND DAMAGE PRIOR TO COVERING WITH
CONCRETE.
5. SEE…