This federal contract opportunity notice solicits bids for the construction of a new cemetery in Elko, Nevada. The Department of Veterans Affairs National Cemetery Administration issued solicitation number 36C78623B0029 to procure cemetery construction services at location 943-001. Bidders must submit responses by the deadline of June 23, 2023 and provide the required bid documents and construction plans, which total 15MB across 8 files. The awarded contractor will be responsible for building a new burial ground to serve veterans in the Elko area. Pricing terms, response deadlines, and other contractual requirements are detailed in the solicitation documentation.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M-001
MECHANICAL GENERAL NOTES,
ABBREVIATIONS & SYMBOLS
A.ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE
CONCEALED IN FURRED CHASES OR SUSPENDED CEILINGS,
UNLESS OTHERWISE NOTED.
B.PROVIDE ACCESS PANELS OR DOORS IN INACCESSIBLE CEILINGS
AND/OR CHASES FOR ALL VALVES, TRAPS, DAMPERS,
CLEANOUTS, COILS, FANS, CONTROLS, ETC. ACCESS DOOR
RATING SHALL MATCH CLASSIFICATION OF WALL AND CEILING
FIRE RATING.
C.COORDINATE THE LOCATION OF ALL DIFFUSERS, GRILLES,
REGISTERS, ACCESS DOORS, ETC., WITH THE ARCHITECTURAL
REFLECTED CEILING PLAN(S).
D. ALL ROUND RUN OUTS AND DROPS TO DIFFUSERS SHALL BE THE
SAME NOMINAL SIZE AS THE SCHEDULED DIFFUSER NECK SIZE.
E. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE
SHOWN OR INDICATED. ALL DUCT SIZES SHOWN ON DRAWINGS
ARE NET INSIDE DIMENSIONS.
F. PROVIDE TURNING VANES IN ALL SQUARE ELBOWS. EXCEPT
TRANSFER AIR SOUND ELBOWS.
G.THE CFM OF EACH DIFFUSER, REGISTER, ETC., IS INDICATED IN
THE SYMBOL DESIGNATION ON THE DRAWINGS.
H.REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT
LOCATION OF ALL FIRE RATED AND/OR SMOKE RATED WALLS AND
ASSEMBLIES. PROVIDE APPROVED FIRE AND FIRE/SMOKE
DAMPERS IN ALL REQUIRED PENETRATIONS FOR DUCTWORK,
GRILLES, REGISTERS AND DIFFUSERS. ALL PIPE AND DUCTWORK
PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT WALLS SHALL
BE CAULKED AIR TIGHT TO THE ADJACENT STRUCTURE BY MEANS
OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.
I. CONTRACTOR SHALL COORDINATE ALL DUCTWORK, PIPING.
PLUMBING AND FIRE PROTECTION PIPING WITH STRUCTURAL AND
ELECTRICAL SYSTEMS AND SHALL PROVIDE NECESSARY
OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN EQUIPMENT
ACCESS AND SERVICEABILITY.
J. CONTRACTOR SHALL FURNISH ALL NECESSARY STRUCTURES,
INSERTS, SLEEVES, AND HANGING DEVICES FOR INSTALLATION
OF MECHANICAL AND PLUMBING EQUIPMENT, DUCTWORK AND
PIPING. ETC. CONTRACTOR SHALL COORDINATE WITH GENERAL
CONTRACTOR AND ALL BUILDING TRADES TO AVOID CONFLICTS
AND TO MAINTAIN EQUIPMENT ACCESS AND SERVICEABILITY.
K. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL
NECESSARY MISCELLANEOUS ANGLES, CHANNELS. UNISTRUT,
ETC., AS MAYBE REQUIRED TO ADEQUATELY SUPPORT THE
MECHANICAL PIPING. DUCTWORK, AND EQUIPMENT IN A MANNER
APPROVED BY THE ARCHITECT WHICH WILL NOT OVERLOAD THE
BUILDING STRUCTURAL SYSTEM.
L. SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS,
DUCTWALL PENETRATIONS AND FITTING CONNECTIONS ON ALL
DUCT SYSTEMS.
GENERAL NOTES
A/E ARCHITECT / ENGINEER
AAV AUTOMATIC AIR VENT
ACD AUTOMATIC CONTROL DAMPER,MODULATING
ACD-TP AUTOMATIC CONTROL DAMPER,TWO POSITION
AD ACCESS DOOR
AF AFTER FILTER
AFCV AIR FLOW CONTROL VALVE
AFF ABOVE FINISHED FLOOR
AFW AIR FOIL WHEEL (FAN)
AHU AIR-HANDLING UNIT
AMP AMPERAGE
AP ACCESS PANEL
APD AIR PRESSURE DROP
ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE
AS AIR SEPARATOR
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
B BOILER
BD BUTTERFLY DAMPER
BDD BACKDRAFT DAMPER
BDR BASE BOARD RADIATOR
BFP BACKFLOW PREVENTER
BFT BOILER PLANT FIRE TUBE
BG BOTTOM GRILLE
BHP BRAKE HORSEPOWER
BHW HOT WATER HEATING BOILER
BHX BOILER BLOWDOWN HEAT EXCHANGER
BIW BACKWARD INCLINED WHEEL (FAN)
BMT BONE MARROW TRANSPLANT
BR BOTTOM REGISTER
BSC BIOLOGICAL SAFETY CABINETS
BT BLOWOFF TANK
BTC BLOWOFF TANK CONTROL VALVE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
BWT BOILER PLANT WATER TUBE
C CENTIGRADE (CELSIUS)
CC COOLING COIL
CCD COOLING COIL CONDENSATE DRAIN
CD CEILING DIFFUSER
CD-1 CONSTRUCTION DOCUMENTS (SUBMISSION1)
CD-2 CONSTRUCTION DOCUMENTS (SUBMISSION2)
CENT CENTRIFUGAL
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CFT CUBIC FEET
CFP CHEMICAL FEED PUMP
CG CEILING GRILLE
CH CHILLER
CHP CHILLED WATER PUMP
CHW CHILLER WATER
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CI CAST IRON
CM CARBON MONOXIDE
CM CUBIC METER
CM/S CUBIC METER PER SECOND
CO CLEAN OUT
CO2 CARBON DIOXODE
COMP COMPRESSOR UNIT
COP COEFFICIENT OF PERFORMANCE
CP CONDENSATE PUMP
CR CEILING REGISTER
CS CONDENSATE STORAGE TANK
CSG CLEAN STEAM GENERATOR
CT COOLING TOWER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CV CONSTANT VOLUME
CW COLD WATER (POTABLE)
CWCC CHILLED WATER COOLING COIL
CWP CONDENSER WATER PUMP
CWR CONDENSER WATER RETURN (TO COOLING TOWER)
CWS CONDENSER WATER SUPPLY (FROM COOLING TOWER)
D DAMPER - AUTOMATIC
D-1 OUTDOOR AIR DAMPER
D-2 RETURN AIR DAMPER
D-3 RELIEF AIR DAMPER
DB DECIBELS
Db DRY-BULB TEMPERATURE
DD-1 DESIGN DEVELOPMENT (SUBMISSION1)
DD-2 DESIGN DEVELOPMENT (SUBMISSION2)
DDC DIRECT DIGITAL CONTROLS
DEG DEGREE
DF DIFFUSER
DIA DIAMETER
DIW DEIONIZED WATER
DP DEW POINT TEMPERATURE
DP DIFFUSER PLATE
DPA DIFFERENTIAL PRESSURE ASSEMBLY
DPS DIFFERENTIAL PRESSURE SENSOR
DX DIRECT EXPANSION
DXCC DIRECT EXPANSION COOLING COIL
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC EVAPORATIVE COOLER
ECC ENGINEERING CONTROL CENTER
ECU EVAPORATIVE CONDENSER UNIT
EDH ELECTRIC DUCT HEATER
EER ENERGY EFFICIENCY RATIO
EF EXHAUST FAN
EG EXHAUST GRILLE
EGS EMERGENCY GAS SHUTOFF
EGT ENTERING GLYCOL TEMPERATURE
EH EXHAUST HOOD
EJ EXPANSION JOINT
EMD END OF MAIN DRIP (STEAM)
ENT ENTERING
ER EXHAUST REGISTER
ERC ELECTRIC REHEAT COIL
ERP ELECTRIC RADIANT PANEL
ESP EXTERNAL STATIC PRESSURE
ET EXPANSION TANK
ETO ETHYLENE OXIDE
EUH ELECTRIC UNIT HEATER
EWC EVAPORATIVE WATER COOLER
EWT ENTERING WATER TEMPERATURE
EX EXISTING
F FAHRENHEIT
F&T FLOAT AND THERMOSTATIC
F/SDPR COMBINATION FIRE SMOKE DAMPER
FA FREE AREA
FC FLEXIBLE CONNECTION
FCU FAN COIL UNIT (4 PIPE)
FCUC FAN COIL UNIT COOLING ONLY
FCUH FAN COIL UNIT HEATING ONLY
FCW FORWARD CURVED WHEEL (FAN)
FD FLOOR DRAIN
FD FIRE DAMPER
FF FINAL FILTER
FHX FLUE GAS/FEEDWATER HEAT EXCHANGER
FM FLOW METER
FOP FUEL OIL PUMP
FOT FUEL OIL TANK
FOHX FUEL OIL HEAT EXCHANGER
FPM FEET PER MINUTE
FPS FEET PER SECOND
FPTU FAN POWERED TERMINAL UNIT
FR FLOOR REGISTER
FRP FIBER REINFORCED POLYESTER
FS FLOW SWITCH
FSTAT FREEZESTAT
GA GAUGE
GAL GALLONS
GH GRAVITY HOOD
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GPR GAS PRESSURE REGULATOR
GS GALVANIZED STEEL
H HUMIDIFIER
H&CW HOT & COLD WATER
HAC HOUSEKEEPING AID CLOSET
HB HOSE BIBB
HC HEATING COIL
HD HEAD
HD HOOD
HOA HAND/OFF/AUTOMATIC
HP HEAT PUMP
HP HORSEPOWER
HPDT HIGH PRESSURE DRIP TRAP
HPR HIGH PRESSURE RETURN (STEAM CONDENSATE)
HPS HIGH PRESSURE SUPPLY (STEAM)
HRC HEAT RECOVERY COIL
HRD HEAT RECOVERY DEVICE
HRP HYDRONIC RADIANT (CEILING) PANEL
HRW HEAT RECOVERY WHEEL
HSTAT HUMIDISTAT
HTM HUMIDIFIER TERMINAL
HUM HUMIDIFIER UNIT MOUNTED
HVU HEATING AND VENTILATING UNIT
HW HOT WATER
HWC HOT WATER COIL
HWHC HOT WATER HEATING COIL
HWP HEATING HOT WATER PUMP
HWR HEATING HOT WATER RETURN
HWS HEATING HOT WATER SUPPLY
HWUH HOT WATER UNIT HEATER
HVD HOISTWAY VENT DAMPER
HX HEAT EXCHANGER
HZ HERTZ
I/O INPUT/OUTPUT
IAQ INDOOR AIR QUALITY
IBT INVERTED BUCKET TRAP
ICF IN-LINE CENTRIFUGAL FAN
ICU INTENSIVE CARE UNIT
ID INSIDE DIAMETER
IFB INTEGRAL FACE AND BYPASS
IN INCHES
IN HG INCHES OF MERCURY
IN WC INCH WATER COLUMN
IN WG INCH WATER GAUGE
IN-LB INCH-POUND
IPLV INTEGRATED PART LOAD VALUE
IRH INFRARED HEATER
IS INSECT SCREEN
IU INDUCTION UNIT
IV INLET VANES
kg KILOGRAM kg/HR KILOGRAM PER HOUR kPa KILOPASCAL kW KILOWATT kWh KILOWATT HOUR
L LITER
L/h LITERS PER HOUR (OR LITERS/HOUR) L/m LITERS PER MINUTE (OR LITERS/MINUTE) L/s LITERS PER SECOND (OR LITERS/SECOND)
LAT LEAVING AIR TEMPERATURE
LBS/HR POUNDS PER HOUR
LF LINEAR FOOT (FEET)
LGT LEAVING GLYCOL TEMPERATURE
LH LATENT HEAT
LPG LIQUID PROPANE GAS
LPR LOW PRESSURE RETURN (STEAM CONDENSATE)
LPRC LOW PRESSURE STEAM RETURN (CLEAN)
LLHX LIQUID TO LIQUID HEAT EXCHANGER
LPS LOW PRESSURE STEAM
LPSC LOW PRESSURE STEAM (CLEAN)
LSD LINEAR SLOT DIFFUSER
LTCP LOCAL TEMPERATURE CONTROL PANEL
LVG LEAVING
LVR LOUVER
LWT LEAVING WATER TEMPERATURE
M METER, SI UNIT
M/s METERS PER SECOND (OR METERS/SECOND)
MA MIXED AIR
MAT MIXED AIR TEMPERATURE
MAU MAKE-UP AIR UNIT
MAV MANUAL AIR VENT
MAX MAXIMUM
MB MIXING BOX
MBH 1000 BTUH
MCA MINIMUM BRANCH CIRCUIT AMPACITY
MER MECHANICAL EQUIPMENT ROOM
MERV MINIMUM EFFICIENCY REPORTING VALUE
MH MANHOLE
MHP MOTOR HORSEPOWER
MIN MINIMUM
MM MILLIMETER
MOV MOTOR OPERATED VALVE
MPR MEDIUM PRESSURE RETURN (STEAM CONDENSATE)
MPS MEDIUM PRESSURE STEAM
MRI MAGNETIC RESONANCE IMAGING
MTD MEAN TEMPERATURE DIFFERENCE
MVD MANUAL VOLUME DAMPER
MZ MULTI-ZONE
NA NOT APPLICABLE
NC NOISE CRITERIA
NC NORMALLY CLOSED
NG NATURAL GAS
NGFM NATURAL GAS FLOWMETER
NO NORMALLY OPEN
NOAA NATIONAL OCEANIC & ATMOSPHERIC ADMINISTRATION
NOM NOMINAL
NPLV NON-STANDARD PART LOAD VALUE
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OAG OUTSIDE AIR GRILLE
OAI OUTSIDE AIR INTAKE
OD OUTSIDE DIAMETER
OFM OIL FLOWMETER
OR OPERATING ROOM
P PUMP
PA PASCAL
PC PUMPED CONDENSATE
PCF POUNDS PER CUBIC FOOT (FEET)
PD PRESSURE DROP
PEF PROPELLER (TYPE) EXHAUST FAN
PF PRE-FILTER
PG PRESSURE GAGE
PGW PROPYLENE GLYCOL-WATER (SOLUTION)
PHC PREHEAT COIL
PPM PARTS PER MILLION
PRS PRESSURE REGULATING (VALVE) STATION
PRV PRESSURE REGULATING VALVE
PSI POUNDS PER SQUARE INCH
PSIA POUNDS PER SQUARE INCH – ABSOLUTE
PSIG POUNDS PER SQUARE INCH – GAGE
PSS PRIMARY SECONDARY SYSTEM
PSV PRESSURE SAFETY VALVE
PTAC PACKAGED TERMINAL AIR CONDITIONER
R RELOCATE
R/E RETURN OR EXHAUST
RA RETURN AIR
RAT RETURN AIR TEMPERATURE
RDS ROOM DATA SHEETS
RG RETURN GRILLE
RH RELATIVE HUMIDITY
RLA RUN LOAD AMPERE
RN NEW RELOCATED LOCATION
RPM REVOLUTIONS PER MINUTE
RR RETURN REGISTER
SA SUPPLY AIR
SAT SUPPLY AIR TEMPERATURE
SCFM STANDARD CUBIC FEET PER MINUTE
SD SMOKE DETECTOR
SD SUPPLY AIR DIFFUSER
SD-1 SCHEMATIC DESIGN (SUBMISSION1)
SD-2 SCHEMATIC DESIGN (SUBMISSION2)
SDPR SMOKE DAMPER
SEN SENSIBLE HEAT
SF SUPPLY FAN
SG SUPPLY AIR GRILLE
SI SQUARE INCHES
SP STATIC PRESSURE
SP GR SPECIFIC GRAVITY
SPD SUPPLY PROCESS AND DISTRIBUTION
SPS STATIC PRESSURE SENSOR
SQ FT SQUARE FOOT (FEET)
SR SUPPLY AIR REGISTER
T & PCV TEMPERATURE AND PRESSURE CONTROL VALVE
TAB TESTING, ADJUSTING, BALANCE
TD TEMPERATURE DIFFERENCE
TSP TOTAL STATIC PRESSURE
TSTAT THERMOSTAT
TU TERMINAL UNIT
TWU THRU-WALL UNIT
UC UNDER CUT
UL UNDERWRITERS LABORATORY
V VALVE
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER (MANUAL OPPOSED BLADE)
VFD VARIABLE FREQUENCY DRIVE
VHA VETERANS HEALTH ADMINISTRATION
VSD VARIABLE SPEED DRIVE
W WATTS
WB WET-BULB (TEMPERATURE)
WG WATER GAGE
WPD WATER SIDE PRESSURE DROP
YR YEAR
ABBREVIATIONS
LIMIT OF DEMOLITION
DNUP SUPPLY DUCT (UP & DOWN)
VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFF
CONNECT NEW DUCT TO EXISTING DUCT
D
INCLINED RISE, IN DIRECTION OF AIR FLOW
INCLINED DROP, IN DIRECTION OF AIR FLOW
R
DNUP RETURN DUCT (UP & DOWN)
SECTION.)
FC
10x8
FLEXIBLE CONNECTION, EQUIPMENT,
VANED ELBOW (PROVIDE ALL SQUARE OR
RECTANGULAR ELBOWS WITH VANES EVEN IF
SYMBOL IS MISSING)
NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)
EXISTING DUCT TO REMAIN
LOUVER (LOUVER SPECIFIED IN ARCHITECTURAL
SMOKE DAMPER
SD
VD
MANUAL VOLUME DAMPER
EXISTING DUCT TO BE REMOVED
VIBRATION, OR SEISMIC
SUPPLY
RETURN45°
RETURN, NO SPLITTER (45° TAP)
STANDARD BRANCH SUPPLY OR
45°
COMBINATION FIRE/SMOKE DAMPER
F/S DPR
AUTOMATIC CONTROL DAMPER MODULATING
DUCTWORK SYMBOLS
ANCHOR
REDUCER OR INCREASER
DIRECTION OF FLOW
SIDE CONNECTION
ECCENTRIC REDUCER
BOTTOM CONNECTION, 45° OR 90°
TOP CONNECTION, 45° OR 90°
DIRECTION OF PIPE PITCH (DOWN)
UNION
RISE OR DROP IN PIPE
CAPPED OUTLET
PRESSURE GAGE
THERMOMETER
FLOW ELEMENT
FLOAT & THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES SEE DETAIL
PIPING ACCESSORIES SEE DETAIL
INVERTED BUCKET TRAP SET INCLUDING
FE
PIPE UP
PIPE DOWN
REFRIGERANT SIGHT GLASS
TEST PLUG (PRESSURE/TEMPERATURE)
AUTOMATIC AIR VENT
AV
MANUAL AIR VENTMV
THERMOSTATIC TRAP SET INCLUDING
PIPING ACCESSORIES SEE DETAIL
QUICK-COUPLE HOSE CONNECTOR
PIPING SYMBOLS
VENT LINE
CHILLED WATER SUPPLY
CHILLED WATER RETURN
DRAIN LINE
MAKE-UP WATER
EXISTING PIPE TO BE REMOVED
SHUT-OFF VALVE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\j ob s\ va el ko n at io na l c em et ar y\ 1b m ec h-pl bg \s he et s\ m
-0 ge ne ra l n ot es a nd a bb re vi at io ns
.d w g ed it:
ad m in s av ed :5
/2 /2
1:
P M p lo t:5 /2
/2
1:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15795
ELKO NATIONAL CEMETERY
943-001
4/05/2023
3602 JENNINGS WAY, ELKO, NV 89801
100% CONSTRUCTION
DOCUMENTS
Date: Dwg. of 133
IRRIGATION: M.E.P.:GEOTECHNICAL :STRUCTURAL:
AST
7301 OHMS LANE, STE 215
EDINA, MN 55439
952-854-9302
MICHELLE SCHMIDT
WIM
175 JAMES AVE N.
MINNEAPOLIS, MN 55405
763-559-1010
TIM MALOOLY
TERRACON
6949 S. HIGH TECH DRIVE
MIDVALE, UT 84047
801-545-8500
JENNIFER DIERCKSEN
AESUS
1050 E. SOUTHERN AVE, STE 5
TEMPE, AZ 85282
480-454-2861
ORLANDO GONZALES
SPLIT SYSTEM HEAT PUMP SCHEDULE
MARK MANUFACTURER
CFM ESP
HEAT PUMP UNIT (COIL)
MOCP MCA
MODEL NUMBER
HEAT PUMPCONDENSER
UNIT HP MOCP VOLTS
CONDENSING UNIT
VOLT/Ø
MIN SEER CYCLE
COOLING CAPACITIES
DB WB TOTAL SENSIBLE
BTUHENT AIR
INDOOR
UNIT LBS
OUTDOOR
UNIT LBS REMARKSOA
CFM
HEATING CAPACITIES
BTUHENT AIR
1 DISCONNECT BY ELECTRICAL CONTRACTOR.
ALL REFRIGERANT PIPING FROM CONDENSING UNIT TO A/C UNITS SHALL BE DESIGNED AND SIZED BY EQUIPMENT MANUFACTURER. VERIFY THE INSULATION OF VAPOR LINE AND PROVIDE PROPER SUPPORT FOR REFRIGERATION LINES.
CONTRACTOR SHALL BE CERTIFIED BY EQUIPMENT MANUFACTURER FOR INSTALLATION OF SYSTEM & SHALL INSTALL ALL EQUIPMENT PER MANUFACTURERS RECOMMENDATION.
PROVIDE DIGITAL NON-PROGRAMMABLE THERMOSTAT, TRANE MODEL# TCONT401AN21MA (XR401).
PROVIDE LOW AMBIENT KIT AND HAIL GUARD.
SEE OUTSIDE AIR CALCULATION FOR MINIMUM OUTSIDE AIR PER UNIT.
13.2 KW ELECTRIC KW, 208V/1Ø, 80A MOCP
NOTE:
1IU-1
OU-1 GOODMAN 2 3 4 5800 0.5 3/4 15 14.2 25 208/1208/1 14 R-410A
COOLING 80 70.7 63.4 37.1 160 1466ASPT25B14GSZ140251 60 43.5
MCA
EXHAUST FAN SCHEDULE
MARK AIR VOLUME
CFM
STATIC
PRESSURE
VOLTAGE/
PHASELOCATION
TOILET ROOMS/
MOP SINK ROOMS
TYPE/
DRIVE
PROVIDE BACKDRAFT DAMPER WITH EXHAUST FAN.
EXHAUST FAN SHALL RUN ONLY WHILE OCCUPIED. SENSOR SWITCH SHALL ACTIVATE FAN AND LIGHT.
HORSE
POWER MFR./MODEL REMARKS
DRIVE
EF-1 450 0.1 120/1CEILING MOUNTED 118 W BROAN L500 DIRECT
NOTE:
1TOILET ROOMS/
MOP SINK ROOMS 2EF-2 450 0.1 120/1CEILING MOUNTED 118 W BROAN L500 DIRECT
ELECTRIC UNIT HEATER
UH-1 ELECTRIC UNIT
HEATER
VOLTAGE/Ø REMARKSMARK TYPE HPMANUFACTURER
& MODEL NUMBER
26,000
BTU
INPUT
PROVIDE DIGITAL, NON-PROGRAMMABLE THERMOSTAT, 40° F SETPOINT.
PROVIDE CEILING SUSPENSION OR WALL HANGER KIT AS DIRECTED BY MANUFACTURER.
PROVIDE CONCENTRIC AIR VENT KIT.
1 2
CFM
21,600
BTU
OUTPUT
NOTE:
1/30 208/1REZNOR
EGHB - AK3E-7 700
6 7
DIFFUSER & GRILLE SCHEDULE
MANUFACTURER
& MODEL NUMBER DAMPER REMARKSMARK TYPE BORDER COLOR
TG-1 PER ARCHTRANSFER GRILLE WALL MOUNTED NONE 12" X 12" STEEL GRILLE. MODIFY EXACT DIMENSIONS AS
REQUIRED TO FIT FIELD CONDITIONS.PRICE STG1
1TOILET ROOMS/
MOP SINK ROOMS 2EF-3 110 0.1 120/1CEILING MOUNTED 12 W SP-LP0511-1 DIRECT
4/05/2023
100% CD SUBMITTAL
BID DOCUMENTS
BID DOCUMENTS
5/5/2023
WH
MENS
WOMENS
STORAGE 103
PORTICO
TECH
CLOSET
HAC
M-101
PIC/BATHROOM BUILDING MECHANICAL
FLOOR PLAN
MECHANICAL FLOOR PLAN
SCALE: 1/4" = 1'-0"
GENERAL NOTES
1. LIGHTING AND SPRINKLER HEADS TAKE PRECEDENCE OVER
DIFFUSER LOCATION. CONTRACTOR SHALL MAKE NECESSARY
ADJUSTMENT TO DIFFUSERS TO AVOID ANY CONFLICT WITH
LIGHTING LAYOUT AND SPRINKLER HEADS.
2. THERMOSTATS SHALL BE MOUNTED PER ADA REQUIREMENTS.
MAXIMUM HEIGHT FOR FRONT ACCESS SHALL BE 48" AFF. DO
NOT MOUNT ABOVE FIXED COUNTER UNLESS KNEE HOLE
ACCESS IS PROVIDED.
3. CONTRACTOR SHALL COORDINATE ALL FINAL THERMOSTAT
LOCATIONS WITH OWNER AND ARCHITECT PRIOR TO
MOUNTING.
4. THE CONTRACTOR SHALL DO ALL NECESSARY CUTTING OF
WALL AND CEILINGS.
5. NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT
PERMISSION FROM THE ENGINEER.
6. OPENINGS IN FLOORS, WALLS, CEILINGS, ROOFS, ETC. AS A
RESULT OF REMOVED PIPING, DUCTWORK, FLUES,
EQUIPMENT, FIXTURES, ETC SHALL BE PATCHED TO MATCH
EXISTING BUILDING CONSTRUCTION. WORK SHALL BE
PERFORMED BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE
TRADES.
7. DUCTWORK CONSTRUCTION AND INSTALLATION INCLUDING
SHEET METAL GAUGES, REINFORCEMENT, JOINT SEALING, AIR
LEAKAGE, AND DETAILS NOT SPECIFICALLY SHOWN ON
DRAWINGS SHALL BE IN ACCORDANCE WITH CURRENT IMC &
VA DUCT CONSTRUCTION STANDARDS.
8. CONTRACTOR SHALL PROVIDE COORDINATION FOR
DUCTWORK ROUTE DRAWINGS, THIS MUST BE APPROVED BY
ENGINEER PRIOR TO CONSTRUCTION.
9. CONTRACTOR IS RESPONSIBLE FOR PROTECTING OPENING
AND RESPONSIBLE FOR ANY DAMAGE CAUSED BY
CONSTRUCTION METHODS.
10. CONTRACTOR SHALL PERFORM LEAK TEST ON ROOF AFTER
CONSTRUCTION IS COMPLETE AND REPAIR THE ROOF AS
NECESSARY.
KEY NOTES
1. SUPPLY AIR DIFFUSER, 400 CFM.
2. EXHAUST FLUE THRU GABLE WALL. PROVIDE TERMINATION PER
MANUFACTURE.
3. PROVIDE 36x36 ACCESS PANEL.
4. NEW CONDENSING UNIT MOUNTED ON NEW 6" HIGH CONCRETE
HOUSEKEEPING PAD. PROVIDE PROTECTIVE CAGE FOR
CONDENSING UNIT.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\j ob s\ va el ko n at io na l c em et ar y\ 1b m ec h-pl bg \s he et s\ m
-1 m ec ha ni ca l p la n.
dw ad av ed :4
/1 1/
:4
AM
lo t:5 /2
/2
1:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15795
ELKO NATIONAL CEMETERY
943-001
2/10/2023
3602 JENNINGS WAY, ELKO, NV 89801
100% CONSTRUCTION
DOCUMENTS
Date: Dwg. of 133
IRRIGATION: M.E.P.:GEOTECHNICAL :STRUCTURAL:
AST
7301 OHMS LANE, STE 215
EDINA, MN 55439
952-854-9302
MICHELLE SCHMIDT
WIM
175 JAMES AVE N.
MINNEAPOLIS, MN 55405
763-559-1010
TIM MALOOLY
TERRACON
6949 S. HIGH TECH DRIVE
MIDVALE, UT 84047
801-545-8500
JENNIFER DIERCKSEN
AESUS
1050 E. SOUTHERN AVE, STE 5
TEMPE, AZ 85282
480-454-2861
ORLANDO GONZALES
IU-1
CU-1
UH-1
TG-1
T
T
12X12
10"Ø
10"Ø
TG-1
EF-1
EF-2
EF-3
4/05/2023
100% CD SUBMITTAL
BID DOCUMENTS
HANGAR
STRAPS
DUCT
1" MIN SCREWS
(TYPICAL)
60"
MAX
LOAD RATED
FASTENER
DUCT (24"Ø MAX)
HANGER
R
IG
ID
D
U C
T H
AN
G
ER
S
D
ET
AI
L
INTEGRAL
GRILLE
EXHAUST
FAN
CEILING
NOTE: INSTALL EXHAUST FAN PER
MANUFACTURER'S RECOMMENDATION.
EX
H
AU
ST
F
AN
R O
O F
D
IS
C H
AR
G
E D
ET
AI
L
O U
TD
O
O R
C U
M O
U N
TI
N
G D
ET
AI
L
RUBBER
SHEAR
ISOLATORS
(4 REQ'D)
REFRIGERANT LIQUID
& SUCTION LINES.
SIZE & INSTALL PER
MANUFACTURER'S
RECOMMENDATIONS.
NEW CURB
AT GRADE
REFRIGERANT LIQUID
& SUCTION LINES.
NOTE:
OUTDOOR
CONDENSING
UNIT
CONCRETE PAD. SEE
STRUCTURAL DRAWING
FOR DETAILS
C O
N D
EN
SA
TE
D
R
AI
N T
R
AP
D
ET
AI
L
BALL VALVE. PLACE AS NEAR TO UNIT
AS POSSIBLE. DO NOT PLACE ELBOW
BETWEEN BALL VALVE AND UNIT.
3/4" 90° ELBOWS (TYP BOTH DRAINS)
P-TRAPS. MAINTAIN MINIMUM 3: DROP
FOLLOWED BY 2" RISE.
3/4" "TEE"
3/4" "TEE"
3/4" FEMALE THREADED HOSE FITTING
WITH 3/4" THREADED REMOVABLE
AIRTIGHT CAP.
M-102
PIC/BATHROOM BUILDING MECHANICAL
DETAILS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\j ob s\ va el ko n at io na l c em et ar y\ 1b m ec h-pl bg \s he et s\ m
-1 m ec ha ni ca l p la n.
dw ad av ed :4
/1 1/
:4 lo t:5 /2
/2
1:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15795
ELKO NATIONAL CEMETERY
943-001
2/10/2023
3602 JENNINGS WAY, ELKO, NV 89801
100% CONSTRUCTION
DOCUMENTS
Date: Dwg. of 133
IRRIGATION: M.E.P.:GEOTECHNICAL :STRUCTURAL:
AST
7301 OHMS LANE, STE 215
EDINA, MN 55439
952-854-9302
MICHELLE SCHMIDT
WIM
175 JAMES AVE N.
MINNEAPOLIS, MN 55405
763-559-1010
TIM MALOOLY
TERRACON
6949 S. HIGH TECH DRIVE
MIDVALE, UT 84047
801-545-8500
JENNIFER DIERCKSEN
AESUS
1050 E. SOUTHERN AVE, STE 5
TEMPE, AZ 85282
480-454-2861
ORLANDO GONZALES 1194/05/2023
100% CD SUBMITTAL
BID DOCUMENTS
COMMITTAL
SHELTER
STORAGE
M-103
COMMITTAL SHELTER BUILDING
MECHANICAL FLOOR PLAN
MECHANICAL FLOOR PLAN
SCALE: 1/4" = 1'-0"
GENERAL NOTES
1. LIGHTING AND SPRINKLER HEADS TAKE PRECEDENCE OVER
DIFFUSER LOCATION. CONTRACTOR SHALL MAKE NECESSARY
ADJUSTMENT TO DIFFUSERS TO AVOID ANY CONFLICT WITH
LIGHTING LAYOUT AND SPRINKLER HEADS.
2. THERMOSTATS SHALL BE MOUNTED PER ADA REQUIREMENTS.
MAXIMUM HEIGHT FOR FRONT ACCESS SHALL BE 48" AFF. DO
NOT MOUNT ABOVE FIXED COUNTER UNLESS KNEE HOLE
ACCESS IS PROVIDED.
3. CONTRACTOR SHALL COORDINATE ALL FINAL THERMOSTAT
LOCATIONS WITH OWNER AND ARCHITECT PRIOR TO
MOUNTING.
4. THE CONTRACTOR SHALL DO ALL NECESSARY CUTTING OF
WALL AND CEILINGS.
5. NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT
PERMISSION FROM THE ENGINEER.
6. OPENINGS IN FLOORS, WALLS, CEILINGS, ROOFS, ETC. AS A
RESULT OF REMOVED PIPING, DUCTWORK, FLUES,
EQUIPMENT, FIXTURES, ETC SHALL BE PATCHED TO MATCH
EXISTING BUILDING CONSTRUCTION. WORK SHALL BE
PERFORMED BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE
TRADES.
7. DUCTWORK CONSTRUCTION AND INSTALLATION INCLUDING
SHEET METAL GAUGES, REINFORCEMENT, JOINT SEALING, AIR
LEAKAGE, AND DETAILS NOT SPECIFICALLY SHOWN ON
DRAWINGS SHALL BE IN ACCORDANCE WITH CURRENT IMC &
VA DUCT CONSTRUCTION STANDARDS.
8. CONTRACTOR SHALL PROVIDE COORDINATION FOR
DUCTWORK ROUTE DRAWINGS, THIS MUST BE APPROVED BY
ENGINEER PRIOR TO CONSTRUCTION.
9. CONTRACTOR IS RESPONSIBLE FOR PROTECTING OPENING
AND RESPONSIBLE FOR ANY DAMAGE CAUSED BY
CONSTRUCTION METHODS.
10. CONTRACTOR SHALL PERFORM LEAK TEST ON ROOF AFTER
CONSTRUCTION IS COMPLETE AND REPAIR THE ROOF AS
NECESSARY.
KEY NOTES
1. CEILING MOUNTED ELECTRIC UNIT HEATER.
2. EXHAUST FLUE THRU GABLE WALL. PROVIDE TERMINATION PER
MANUFACTURE.
3. PROVIDE 36x36 ACCESS PANEL.
4. NEW CONDENSING UNIT MOUNTED ON NEW 6" HIGH CONCRETE
HOUSEKEEPING PAD. PROVIDE PROTECTIVE CAGE FOR
CONDENSING UNIT.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\j ob s\ va el ko n at io na l c em et ar y\ 1b m ec h-pl bg \s he et s\ m
-1 m ec ha ni ca l p la n.
dw ad av ed :4
/1 1/
:4 lo t:5 /2
/2
1:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15795
ELKO NATIONAL CEMETERY
943-001
2/10/2023
3602 JENNINGS WAY, ELKO, NV 89801
100% CONSTRUCTION
DOCUMENTS
Date: Dwg. of 133
IRRIGATION: M.E.P.:GEOTECHNICAL :STRUCTURAL:
AST
7301 OHMS LANE, STE 215
EDINA, MN 55439
952-854-9302
MICHELLE SCHMIDT
WIM
175 JAMES AVE N.
MINNEAPOLIS, MN 55405
763-559-1010
TIM MALOOLY
TERRACON
6949 S. HIGH TECH DRIVE
MIDVALE, UT 84047
801-545-8500
JENNIFER DIERCKSEN
AESUS
1050 E. SOUTHERN AVE, STE 5
TEMPE, AZ 85282
480-454-2861
ORLANDO GONZALES
T
ELECTRIC UNIT HEATER
UH-2 ELECTRIC UNIT
HEATER 208/1
VOLTAGE/Ø REMARKSMARK TYPE
MANUFACTURER
& MODEL NUMBER
KW
PROVIDE DIGITAL, NON-PROGRAMMABLE THERMOSTAT, 40° F SETPOINT.
PROVIDE CEILING SUSPENSION OR WALL HANGER KIT AS DIRECTED BY MANUFACTURER.
1 2
CFM
14.5
AMPS
NOTE: NO SUBSTITUTIONS ARE ALLOWED.
UH-2
1204/05/2023
100% CD SUBMITTAL
BID DOCUMENTS
P-001
PLUMBING GENERAL NOTES,
ABBREVIATIONS & SYMBOLS
PLUMBING ABBREVIATIONS
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
BFF BELOW FINISHED FLOOR
BFG BELOW FINISHED GRADE
BV BALANCING VALVE
CFR CLEAN FUEL OIL RETURN
CFS CLEAN FUEL OIL SUPPLY
CO CLEANOUT
COF COFFEE MACHINE
COMP COMPARTMENT
CW COLD WATER
DFU DRAINAGE FIXTURE UNIT
DI DEIONIZED WATER
DN DOWN
ELEV ELEVATION
EVS ENVIRONMENTAL SERVICES
EXT EXTERIOR
F FUTURE
FCO FLOOR CLEANOUT
FDC FIRE DEPARTMENT CONNECTION
FFE FINISHED FLOOR ELEVATION
FIN FINISHED
FLR FLOOR
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOV FUEL OIL VENT
FP FIRE PROTECTION/SPRINKLER
G GAS
GCO GRADE CLEANOUT
GV GREASE VENT
GVTR GREASE VENT THRU ROOF
GW GREASE WASTE
HUM HUMIDIFIER
HW HOT WATER (120F)
HWR HOT WATER RETURN (120)
ICE ICE MACHINE
IE INVERT ELEVATION
INT INTERIOR
INV INVERT
IV INDUSTRIAL WASTE VENT
IW INDUSTRIAL WASTE
LP LOW PRESSURE
LPG LOW PRESSURE GAS
M METER
MAX MAXIMUM
MH MANHOLE
MIN MINIMUM
MPG MEDIUM PRESSURE GAS
NAT NATURAL
NC NORMALLY CLOSED
NO NORMALLY OPEN
OD OVERFLOW DRAIN
ODL OVERFLOR DRAIN LEADER
OR OPERATING ROOM
PRV PRESSURE REDUCTING VALVE
RD ROOF DRAIN
RDL ROOF DRAIN LEADER
REF REFERENCE
RI&C ROUGH IN AND CONNECT
RO REVERSE OSMOSIS
SA SHOCK ARRESTOR
SCW SOFT COLD WATER
SF SQUARE FEET
SOV SHUT-OFF VALVE
SSD SUB-SOIL DRAIN
THRU THROUGH
U/G UNDERGROUND
ULT ULTRASONIC CLEANER
V VENT
VTR VENT THROUGH ROOF
WC WATER COLUMN
WCO WALL CLEANOUT
WM WATER METER
WSFU WATER SUPPLY FIXTURE UNIT
WTR WATER DISPENSER
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
W.
X.
Y.
Z.
AA.
AB.
AC.
ALL WORK TO COMPLY WITH ALL VA TIL REQUIREMENTS AND LOCALLY ADOPTED
CODES.
REFER TO SPECIFICATIONS FOR MATERIALS AND METHODS FOR MECHANICAL
AND PLUMBING CONSTRUCTION.
OBTAIN ALL NECESSARY PERMITS, PAY ALL FEES, AND COMPLY WITH ALL
FEDERAL, STATE, AND MUNICIPAL LAWS, CODES, AND ORDINANCES RELATING
TO BUILDING AND PUBLIC SAFETY.
FURNISH ALL MATERIALS, EQUIPMENT, AND LABOR REQUIRED FOR A
COMPLETE WORKING AND COORDINATED SYSTEM.
COORDINATE THE EXACT LOCATION OF PLUMBING PIPING AND EQUIPMENT
WITH THE LOCATIONS OF LIGHT FIXTURES, MECHANICAL SYSTEMS, CONDUIT,
AND OTHER CONSTRUCTION, TO ALLOW FOR PROPER ACCESS TO SERVICE
EQUIPMENT.
IT IS THE REQUIREMENT OF THESE DOCUMENTS TO ALLOW ALL CEILINGS TO BE
CONSTRUCTED AT HEIGHTS AS SHOWN ON THE ARCHITECTURAL DRAWINGS.
COORDINATE THE LOCATION OF PIPING AND PROVIDE OFFSETS IN PIPING AS
REQUIRED TO MEET THIS REQUIREMENT.
ALL PIPING SHALL BE INDEPENDENTLY SUPPORTED, AND EACH SUPPORT
SHALL BE INDEPENDENT OF PARTITION AND CEILING SYSTEM SUPPORTS.
WHERE INDEPENDENT SUPPORT IS NOT POSSIBLE AN ENGINEERED SUPPORT
SYSTEM SHALL BE UTILIZED.
ALL WORK SHALL BE SCHEDULED AND PERFORMED IN STRICT COORDINATION
WITH ARCHITECTURAL PLANS AND WITH FACILITY SCHEDULES, OCCUPANCIES,
AND WORK. COORDINATE WITH FACILITY REPRESENTATIVE.
PROTECT EQUIPMENT AND FIXTURES FROM DAMAGE DURING HANDLING AND
INSTALLATION UNTIL COMPLETION OF CONSTRUCTION.
REMOVE ALL EXCESS MATERIAL AND DEBRIS AND CLEAN ALL EQUIPMENT UPON
COMPLETION OF WORK. TOUCH UP WITH PAINT WHERE REQUIRED.
CONTRACTOR SHALL VISIT JOB SITE AND VERIFY SIZE AND LOCATION OF ALL
EXISTING ITEMS AND CONDITIONS.
ALL CONNECTIONS BETWEEN PIPES OF DISSIMILAR MATERIALS SHALL BE MADE
WITH DIELECTRIC UNIONS.
COORDINATE ALL NEW WORK WITH ALL TRADES. WORK SHOWN ON THESE
DRAWINGS ARE INTENDED TO PROVIDE THE OVERALL ENGINEERING DESIGN
CONCEPT AND DOES NOT PROVIDE FOR RELOCATIONS, OFFSETS, ETC., THAT
ARE REQUIRED BY THE COORDINATION OF TRADES SHALL BE PROVIDED BY
THE CONTRACTOR AT NO ADDITIONAL COST TO THE CONTRACT.
THE EXISTING FACILITIES SHALL BE PROTECTED DURING THE CONSTRUCTION
ACTIVITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO STORE,
RELOCATE, AND REUSE ITEMS WHICH ARE SUBJECT TO DAMAGE.
COORDINATE ALL WALL MOUNTED DEVICE LOCATIONS WITH ARCHITECTURAL
INTERIOR ELEVATIONS.
DEMOLITION OF THE AREA SHALL OCCUR AS PART OF THE WORK FOR THAT
AREA. REMOVE ONLY THE PLUMBING THAT SERVES THE AREA OF DEMOLITION.
PROVIDE ADDITIONAL VALVES, TAPS, TEMPORARY PIPING, ETC. AS NECESSARY
TO PROVIDE UNINTERRUPTED SERVICE TO AREAS OUTSIDE OF THE PROJECT
IN WHICH WORK IS BEING PERFORMED.
ALL NECESSARY SHUTDOWNS IN OR OUT OF THE WORK AREA SHALL BE
COORDINATED AND SCHEDULED WITH THE FACILITY REPRESENTATIVE.
LOCATE ISOLATION VALVES FOR EQUIPMENT AND FIXTURES AS CLOSE TO THE
MAIN AS POSSIBLE. PROVIDE CEILING OR WALL ACCESS PANELS AS NEEDED.
ALL PLUMBING EQUIPMENT OR VALVES REQUIRING ACCESS THAT IS LOCATED
ABOVE GYP. BOARD OR OTHERWISE INACCESSIBLE CEILING SHALL BE
PROVIDED WITH A CEILING ACCESS PANEL SUPPLIED AND INSTALLED BY THE
GENERAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL COORDINATE
THE EXACT LOCATION OF THESE ACCESS PANELS WITH THE GENERAL
CONTRACTOR.
PROVIDE DETAILED AND DIMENSIONED PIPING FABRICATION DRAWINGS FOR
APPROVAL BY THE ARCHITECT/ENGINEER. ONE BLUE-LINE SET OF THE
APPROVED DRAWINGS SHALL BE KEPT ON-SITE AT ALL TIMES AND ANY
CHANGES REQUIRED IN THE FIELD SHALL BE MARKED ON THESE DRAWINGS. AT
THE END OF THE PROJECT, ALL CHANGES SHALL BE TRANSFERRED TO A
REPRODUCIBLE DRAWING TO BE GIVEN TO THE OWNER FOR "AS-BUILT"
DRAWINGS. REPRODUCTIONS OF THIS DRAWING WILL NOT BE CONSIDERED AS
PIPING FABRICATION DRAWINGS.
ALL PLUMBING PIPING SHALL BE IDENTIFIED IN ACCORDANCE WITH SECTION
220553 OF THE SPECIFICATIONS.
ALL MAJOR AND SECTIONAL BALANCING VALVES SHALL BE TAGGED AND NOTED
ON THE "AS-BUILT" DRAWINGS.
SLOPE AND ARRANGE WATER PIPING SYSTEMS TO ESTABLISH HIGH POINTS
FOR AIR ELIMINATION AND LOW POINTS TO PERMIT PROPER DRAINING OF EACH
LINE.
COORDINATE ALL PIPING ROOF PENETRATIONS AND FLOOR PENETRATIONS
WITH STRUCTURAL. DUCT OPENINGS THROUGH ROOF SHALL BE THE SAME
REQUIRED FOR THE DUCT AND INSULATION ONLY.
TEST ALL SEWER, WATER, AND MEDICAL GAS PRIOR TO BACKFILL AND COVER.
CALL FOR INSPECTION AND WITNESS TESTING PRIOR TO CONCEALING SEWER,
WATER, AND MEDICAL GAS PIPING.
PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH
A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT
GASES. ALL MATERIALS TO BE APPROVED OR LISTED.
FLUSH AND DISINFECT ALL POTABLE WATER PIPING PRIOR TO OCCUPANCY.
ABOVE GROUND DOMESTIC WATER PIPING SHALL BE TYPE "L" HARD COPPER
TUBE.
GENERAL NOTES
HP
R
FCA
M
FLOOR CLEANOUT OR GRADE CLEANOUTFCO
GCO
DRY SPRINKLER PIPING
NON-POTABLE TEMPERED WATER
COMPRESSED AIR PIPING
EXPANSION LOOP
SLEEVE THRU WALL
YARD HYDRANT
PLUMBING SYMBOLS
SYMBOL DESCRIPTION
DOMESTIC COLD WATER
DOMESTIC HOT WATER RETURN (TEMP. AS NOTED)
DOMESTIC HOT WATER (TEMP. AS NOTED)
STORM DRAIN PIPING
CONNECT NEW TO EXISTING
BACKFLOW PREVENTER (RPZ)
COLD OR HOT REDUCED PRESSURE PRINCIPLE
EXISTING PIPING TO BE REMOVED
PIPING TO BE ELECTRICALLY HEAT TRACED
SANITARY SEWER PIPING (SOIL OR WASTE)
SUB-SOIL DRAIN PIPING, FOOTING DRAIN PIPING
SANITARY VENT PIPING
ACID WASTE PIPING
ACID VENT PIPING
INDIRECT WASTE
SEWAGE EJECTOR DISCHARGE PIPING (PUMPED SANITARY)
CONDENSATE DRAIN PIPING
DRAIN PIPING
SUMP PUMP DISCHARGE PIPING
STORM OVERFLOW DRAIN PIPING
NATURAL GAS PIPING
GAS PIPE UNDER THE JURISDICTION OF THE ARIZONA CORPORATION COMMISSION
SPRINKLER PIPING (SPRK.)
GATE VALVE
BUTTERFLY VALVE
BALL VALVE
GLOBE VALVE
TEMPERATURE AND PRESSURE RELIEF VALVE
SOLENOID VALVE
VALVE IN VERTICAL
GAS COCK / PLUG VALVE
PRESSURE REGULATION VALVE (PRV)
AQUASTAT
CHECK VALVE
CHECK VALVE WITH AUTOMATIC BALL DRIP
GAS PRESSURE REGULATOR VALVE
BALANCING VALVE
STRAINER WITH BLOW-OFF VALVE
STRAINER
SHOCK ARRESTOR SA-(A)
WATER FLOW METER
HUB DRAIN
FLOOR DRAIN
2-WAY CLEANOUT (GRADE) (GCO)
PRESSURE GAUGE WITH GAUGE COCK
THERMOMETER WITH SHUT-OFF COCK
HOSE BIBB (HB) OR WALL HYDRANT (WH)
SSD
AW
AV
IW
SED
SD
D
CD
OD
SPD
G
CA
SP
NPTW
DSP
SA-A
FLOOR SINK
FD
FS
HD
ROOF DRAINRD
OVERFLOW ROOF DRAINOD
HIGH PRESSURE COLD WATER
GREASY WASTE SEWER PIPINGGW
ACC
WALL CLEANOUT
CLEANOUT PLUG
WCO
CO
FS
UNION
CAP OUTLET OR PLUGGED OUTLET
DIRECTION OF FLOW
DIRECTION OF SLOPE
SIAMESE FIRE DEPARTMENT CONNECTION
FIRE HOSE VALVE
FLOW SWITCH
DOUBLE CHECK VALVE ASSEMBLY (DCVA) WITH OS & Y VALVES SUPERVISED
SPRINKLER SYSTEM FLOOR CONTROL VALVE ASSEMBLY (FCVA)
OS & Y VALVE SUPERVISED (HORIZ. POSITION/VERT. POSITION)
CO
CAP SANITARY SEWER OR STORM PIPING
DOWNSPOUT NOZZLE (18"A.F.F.)
PUMP
ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS.
SYMBOLS ARE SHOWN SCHEMATICALLY AND MAY NOT BE TO SCALE.
AQ
SS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\j ob s\ va el ko n at io na l c em et ar y\ 1b m ec h-pl bg \s he et s\ p-
- g en er al n ot es a nd a bb re vi at io ns
.d w ad av ed :4
/1 1/
:4 lo t:5 /2
/2
1:
P
M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15795
ELKO NATIONAL CEMETERY
943-001
2/10/2023
3602 JENNINGS WAY, ELKO, NV 89801
100% CONSTRUCTION
DOCUMENTS
Date: Dwg. of 133
IRRIGATION: M.E.P.:GEOTECHNICAL :STRUCTURAL:
AST
7301 OHMS LANE, STE 215
EDINA, MN 55439
952-854-9302
MICHELLE SCHMIDT
WIM
175 JAMES AVE N.
MINNEAPOLIS, MN 55405
763-559-1010
TIM MALOOLY
TERRACON
6949 S. HIGH TECH DRIVE
MIDVALE, UT 84047
801-545-8500
JENNIFER DIERCKSEN
AESUS
1050 E. SOUTHERN AVE, STE 5
TEMPE, AZ 85282
480-454-2861
ORLANDO GONZALES
L-1 LAVATORY
(WALL HUNG)
MARK FIXTURE TYPE VENT SUPPLY
CW HWDESCRIPTION WASTE VENT
LAVATORY: AMERICAN STANDARD #0124.024 COMRADE WALL HUNG LAVATORY: VITREOUS CHINA, 4" CENTERS FAUCET
HOLES.
FAUCET: DELTA 523-HDF-DST 4" CENTERS CHROME FAUCET, 0.5, GPM, VANDAL RESISTANT AERATOR, GRID STRAINER, &
CONCEALED ARM SUPPORT.
ACCESSORIES: PROVIDE WITH 1/2" X 3/8" ANGLE STOPS WITH FLEXIBLE TUBE RISERS. OFFSET P-TRAP AND INSULATED WASTE AND WATER PIPING WITH TRUEBRO MODEL #102 E-Z LAV GUARD. PROVIDE TWO (2) SETS OF FAUCET WASHERS
TO OWNER FOR EACH FAUCET ON PROJECT.
3/4"2" 3/4"
EDF-1 ELECTRIC
WATER COOLER 3/4"2"
MOP SINK 2"2" 3/4" 3/4"MS-1 SINK: FIAT MSB2424, 24x24 MOLDED STONE MOP SINK WITH INTEGRAL STAINLESS STEEL STRAINER EXTENSION.
FAUCET: FIAT SERVICE SINK FAUCET MN: 830-AA CHROME PLATES FAUCET WITH INTEGRAL STOPS, VACUUM BREAKER, 3/4" HOSE THREAD AND WALL BRACE. MOUNT FITTING 24" AFF.
ACCESSORIES: FIAT #832-AA BRACKET, S.S., FIAT #833-AA SILICONE SEALANT INSTALLED PER MANUFACTURER. 50" COMMERCIAL GRADE RUBBER HOSE WITH 400# BURST TEST RATING WITH PISTOL GRIP TRIGGER NOZZLE AND INSULATED NOZZLE. FIAT #889-CC S.S. MOP HANGER, TRIPLE. FIAT #QDC3XH MOP SINK DRAIN GASKET, AND. PROVIDE 'P'
TRAP.
-3/4"FREEZE
PROOF
HOSE BIB
HB-1 --HOSE BIBB: WOODFORD MODEL 24, BRASS BODY WITH INTEGRAL MOUNTING FLANGE, REPLACEABLE HEXAGONAL DISK, THREADED HOSE SPOUT, INTEGRAL VACUUM BREAKER, ANSI/ASSE 1011 CONFORMANT, CHROME PLATED WHERE
EXPOSED WITH HANDWHEEL.
ELKAY, EZ8, SINGLE LEVEL WALL MOUNTED @ ADA COMPLIANT HEIGHT WITH STAINLESS STEEL TOP, INTEGRAL REFRIGERATION SYSTEM TO PROVIDE 8.0 GPH OF 50° F DRINKING WATER @ 90° F AMBIENT TEMPERATURE. SYSTEM
SHALL OPERATE @ 115 VOLT, FLA: 4.0, 370 WATTS, 55 LBS.
PROVIDE WITH EZ-FLO/EASTMAN #04322 1/2" X 3/8" ANGLE STOPS WITH FLEXIBLE TUBE RISER AND LOOSE KEY MOUNTED
BEHIND FIXTURE AND 1-1/2" P-TRAP ASSEMBLY.
WC-1
TOILET
(FLOOR MTD.)
ADA 1" -2"3"
WATER CLOSET: AMERICAN STANDARD VORMAX HET RIGHT HEIGHT ELONGATED TOILET. #238AA.104, VITREOUS CHINA, LOW-CONSUMPTION FLUSH TOILET, FLUSH 1.28 GPF, MEETS EPA WATERSENSE CRITERIA, 16-1/2" RIM HEIGHT FOR
ACCESSIBLE APPLICATIONS, OPEN FRONT SEAT, 2 YEAR WARRANTY.
ACCESSORIES: PROVIDE WITH TWO (2) SETS OF FLUSH VALVE SERVICE KITS FOR EACH WATERCLOSET ON PROJECT.
UR-1 URINAL
ADA 1" -2"3"
URINAL: AMERICAN STANDARD MAYBROOK UNIVERSAL URINAL, VITREOUS CHINA, LOW-CONSUMPTION FLUSH, 0.5 GPF, MEETS EPA WATERSENSE CRITERIA, PERMANENT EVERCLEAN SURFACE, INTEGRAL STRINER, 2 YEAR WARRANTY. FLUSH
VALVE: AMERICAN STANDARD 6045.051.002.
ACCESSORIES: PROVIDE WITH TWO (2) SETS OF FLUSH VALVE SERVICE KITS FOR EACH WATERCLOSET ON PROJECT.
WC-2 TOILET
(FLOOR MTD.)
1" -2"3"
WATER CLOSET: AMERICAN STANDARD PRIOLO FLOW WISE, 16-1/2" ELONGATED FLUSHOMETER TOILET, VITREOUS CHINA, LOW-CONSUMPTION, 1.6 GPF, ELONGATED WASH DOWN BOWL, CONCEALED TRAPWAY BOWL, FOR ACCESSIBLE
APPLICATIONS, OPEN FRONT SEAT, 2 YEAR WARRANTY.
ACCESSORIES: PROVIDE WITH TWO (2) SETS OF FLUSH VALVE SERVICE KITS FOR EACH WATERCLOSET ON PROJECT.
2"
2"
REDUCED
PRESSURE
BACKFLOW
PREVENTER
BFP ZURN WILKINS MODEL # 975XL, AWWA COMPLIANT C511, ASSE® LISTED 1013, IAPMO® LISTED, BRONZE BODY WITH BRONZE AND PLASTIC INTERNAL PARTS AND SS SPRINGS. TWO (2) INDEPENDENTLY OPERATING SPRING LOADED CHECK VALVES, THIRD CHECK VALVE WHICH OPENS UNDER PRESSURE IN CASE OF DIAPHRAGM FAILURE, NON-THREADED VENT
OUTLET: ASSEMBLED WITH TWO (2) GATE VALVES, STRAINER AND FOUR (4) TEST COCKS.
-1/2"--
ELECTRIC WATER HEATER SCHEDULE
MANUFACTURER MODEL STORAGE
CAPACITY
CAPACITY
EWT
F°
LWT
F°
WATTS
(KW) VOLT/Ø
RECOVERY
100 DEGREE
RISE (GPH)
REMARKS
NOTES:
NO SUBSTITUTIONS ARE ALLOWED.
WATER HEATER SHALL BE PROVIDED WITH ASME RATED T&P RELIEF VALVE.
PER DETAIL, PROVIDE THERMOSTATIC MIXING VALVE MODEL # POWERS LM49 WITH INTEGRAL CHECK VALVES AND INLET SCREENS.
PER DETAIL, PROVIDE EXPANSION TANK MODEL # WATTS PLT-5 OR EQUAL, WELDED STEEL, TESTED AND STAMPED IN ACCORDANCE WITH IAMPO AND CERTIFIED TO ANSI/NSF-61, RATED FOR 125 PSI, WITH FLEXIBLE DIAPHRAGM SEALED INTO TANK AND STEEL LEGS OR SADDLE. PROVIDE WITH PRESSURE GAUGE AND AIR CHARGE FITTING, TANK DRAIN & PRECHARGED TO 12 PSI.
STATEWH-1 40PATRIOT
PCE 40-20LSA 14040 4.5 18 240/1 1 2 3
FLOOR
DRAIN
FD-1 WADE MODEL 1100-STD FLOOR DRAIN, 5" TOP SIZE, DURA-COATED CAST IRON BODY WITH BOTTOM OUTLET, WITH
POLISHED BRONZE TOP AND LIGHT DUTY STRAINER.
PROVIDE WITH WADE "TRAP GUARD" INSERT FOR ACTUAL FLOOR DRAIN MODEL AND SIZE PROVIDED, FLEXIBLE ELASTOMERIC PVC MATERIAL MOLDED INTO SHAPE OF DUCK'S BILL, OPEN TOP WITH CURL AT CLOSURE AT BOTTOM, ALLOWS WASTE WATER TO OPEN AND ADEQUATELY DISCHARGE FLOOR DRAIN THROUGH ITS INTERIOR. CLOSES AND
RETURNS TO ORIGINAL MOLDED SHAPE AFTER WASTE WATER DISCHARGE IS COMPLETE.
-2"2" -
SYSTEM TYPE
NEW FIXTURES
41 FU =
MECH GPM REQUIREMENT
TOTAL CURRENT DEMAND (GPM)=
SITE PRESSURE (PSI)
PRESSURE LOSS THRU WATER METER (PSI)
PRESSURE REQUIRED AT FIXTURE (PSI)
PRESSURE LOSS THRU BACKFLOW (PSI)
AVAILABLE PRESSURE (PSI)
FURTHEST FIXTURE DISTANCE (FT)
VERTICAL LENGTH (FT)
ALLOWANCE FOR FITTINGS (FT)
TOTAL DEVELOPED LENGTH (FT)
MAXIMUM ALLOWABLE LOSS PER 100 FT OF
PIPE = 23.6 X 100 / 205 FT =
STATIC LOSS 30 x 0.43 (PSI)
41 FU
26.3 GPM
26.3 GPM
20.5
6.5
23.6
12.9
11.5
LEVEL NAME TOTAL FOR LEVEL
FLUSH VALVE
FUTURE FIXTURES
TOTAL FIXTURES
0 FU
41 FU
FIXTURE UNIT SCHEDULE
QTY
WC
FIXTURE FU/EACH TOTAL FU FU/EACH TOTAL FU
DOMESTIC
WATER WASTE
4 6 24 4 16
L 4 2 8 1 4
EDF 1 1 1 1 1
UR 1 5 5 4 4
41 31
FD 2 0 4
MS
0 2
1 3 3 2 2
BOOSTER
PUMP
BP-1 THE TW1000-10W-40 FLAG FRAME BOOSTER SYSTEM IS EQUIPPED WITH A CENTRIFUGAL PUMP REGULATED BY A VARIABLE FREQUENCY DRIVE THAT CONTROLS PUMP OPERATION TO MAINTAIN CONSTANT PRESSURE REGARDLESS OF VARYING DEMAND OR FLUCTUATION IN INCOMING PRESSURE. THIS SYSTEM WILL SUPPLY 10 GPM WITH A 40 PSI
OVERBOOST. PROVIDE PNEUMATIC EXPANSION TANK PLT-5.
-2"2" -
PACKAGE BOOSTER PUMP SCHEDULE
MANUFACTURER MODEL
PRESSURE
TRANSMITTER
SETPOINT
FLOW WATTS
(KW) VOLT/Ø
RECOVERY
100 DEGREE
RISE (GPH)
REMARKS
TOWLE WHITNEYBP-1 60TW1000-10W-40 10
GPM 0.75 18 208/1
HORSE
POWER
1/2
RE-CIRCULATION PUMP
MANUFACTURER MODEL MAX FT HEAD FLOW AMPS VOLT/Ø REMARKS
TACOCP-1 15 FT008-SF6 10
GPM 0.84 115V AC
HORSE
POWER
1/25
1214/05/2023
100% CD SUBMITTAL
BID DOCUMENTS
WH
MENS
WOMENS
STORAGE
PORTICO
TECH
CLOSET
HAC
STANDING SEAM
METAL ROOF
RIDGE
ROOF SLOPE
6:12
DASHED LINE
INDICATES EXTERIOR
FACE OF WALL BELOW
WOOD FRAMING
SL
OP
E
ROOF SLOPE
6:12
GUTTER
GUTTER
1/2 / 1
METAL SNOW GUARD
TYPICAL
P-101
PIC/BATHROOM BUILDING PLUMBING
FLOOR PLAN & DETAILS
PLUMBING FLOOR PLAN
SCALE: 1/4" = 1'-0"
GENERAL NOTES
1. LIGHTING AND SPRINKLER HEADS TAKE PRECEDENCE OVER
DIFFUSER LOCATION. CONTRACTOR SHALL MAKE NECESSARY
ADJUSTMENT TO DIFFUSERS TO AVOID ANY CONFLICT WITH
LIGHTING LAYOUT AND SPRINKLER HEADS.
2. THERMOSTATS SHALL BE MOUNTED PER ADA REQUIREMENTS.
MAXIMUM HEIGHT FOR FRONT ACCESS SHALL BE 48" AFF. DO
NOT MOUNT ABOVE FIXED COUNTER UNLESS KNEE HOLE
ACCESS IS PROVIDED.
3. CONTRACTOR SHALL COORDINATE ALL FINAL THERMOSTAT
LOCATIONS WITH OWNER AND ARCHITECT PRIOR TO
MOUNTING.
4. THE CONTRACTOR SHALL DO ALL NECESSARY CUTTING OF
WALL AND CEILINGS.
5. NO STRUCTURAL MEMBER SHALL BE CUT WITHOUT
PERMISSION FROM THE ENGINEER.
6. OPENINGS IN FLOORS, WALLS, CEILINGS, ROOFS, ETC. AS A
RESULT OF REMOVED PIPING, DUCTWORK, FLUES,
EQUIPMENT, FIXTURES, ETC SHALL BE PATCHED TO MATCH
EXISTING BUILDING CONSTRUCTION. WORK SHALL BE
PERFORMED BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE
TRADES.
7. DUCTWORK CONSTRUCTION AND INSTALLATION INCLUDING
SHEET METAL GAUGES, REINFORCEMENT, JOINT SEALING, AIR
LEAKAGE, AND DETAILS NOT SPECIFICALLY SHOWN ON
DRAWINGS SHALL BE IN ACCORDANCE WITH CURRENT IMC &
VA DUCT CONSTRUCTION STANDARDS.
8. CONTRACTOR SHALL PROVIDE COORDINATION FOR
DUCTWORK ROUTE DRAWINGS, THIS MUST BE APPROVED BY
ENGINEER PRIOR TO CONSTRUCTION.
9. CONTRACTOR IS RESPONSIBLE FOR PROTECTING OPENING
AND RESPONSIBLE FOR ANY DAMAGE CAUSED BY
CONSTRUCTION METHODS.
10. CONTRACTOR SHALL PERFORM LEAK TEST ON ROOF AFTER
CONSTRUCTION IS COMPLETE AND REPAIR THE ROOF AS
NECESSARY.
KEY NOTES
1. 2-WAY CLEAN OUT
2. BOOSTER PUMP, REFER TO DETAIL 4.
3. REFER TO CIVIL PLANS FOR CONTINUATION.
4. GRADE CLEAN-OUT.
5. PROVIDE 0.5 GPM HW RE-CIRCULATION PUMP.
3 3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\j ob s\ va el ko n at io na l c em et ar y\ 1b m ec h-pl bg \s he et s\ p-
- p lu m bi ng p la n.
dw ad av ed
:5 /2
/2
1:
lo t:5
/2 /2
1:
P M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15795
ELKO NATIONAL CEMETERY
943-001
2/10/2023
3602 JENNINGS WAY, ELKO, NV 89801
100% CONSTRUCTION
DOCUMENTS
Date: Dwg. of 133
IRRIGATION: M.E.P.:GEOTECHNICAL :STRUCTURAL:
AST
7301 OHMS LANE, STE 215
EDINA, MN 55439
952-854-9302
MICHELLE SCHMIDT
WIM
175 JAMES AVE N.
MINNEAPOLIS, MN 55405
763-559-1010
TIM MALOOLY
TERRACON
6949 S. HIGH TECH DRIVE
MIDVALE, UT 84047
801-545-8500
JENNIFER DIERCKSEN
AESUS
1050 E. SOUTHERN AVE, STE 5
TEMPE, AZ 85282
480-454-2861
ORLANDO GONZALES
WH-1
L-1 L-1
L-1 L-1
UR-1
WC-2 WC-1
WC-2 WC-1
EDF-1
MS-1
HB-1
NOT LESS THAN 2"
(TYPICAL)
GRADE
SURFACE CLEANOUT SEE
SPECIFICATIONS (TYPICAL)
CONCRETE SLAB- EXTEND
MINIMUM OF 6" BEYOND
PERIMETER OF CLEANOUTS
FLOWMAIN SEWER
TW
O
-W
AY
C
LE
AN
O
U T
D
ET
AI
L
SEE SPECIFICATIONS FOR PIPE
AND FITTING TYPE.
W
AT
ER
H
EA
TE
R D
IA
G
R
AM
ANCHOR OR SUPPORT WATER HEATER IN SEISMIC AREAS.2.
SEE FLOOR PLAN FOR CONTINUATION AND PIPE SIZES.1.
NOTE:
SUPPORT STAND MIN 18" HIGH
DRAIN VALVE
CHECK VALVE
(TYP)
HOT WATER
SUPPLY
COLD WATER
SUPPLY
ISOLATION VALVE
(TYP)
FINISHED FLOOR
VACUUM RELIEF
VALVE
THERMOMETER
(TYP)
ASME APPROVED
TEMPERATURE &
PRESSURE RELIEF
VALVE
RELIEF PIPE- FULL
SIZE OF
DISCHARGE
OPENING
WATER
HEATER
ET
THERMOSTATIC
MIXING VALVE
DIELECTRIC UNION
EXPANSION TANK
NOTE: NOT TO SCALE
H O
T
AN
D C
O
LD
W
AT
ER
H
O
SE
B
IB
B D
ET
AI
L
FULL PORT BALL VALVES
SHUT-OFF VALVES @ +48" A.F.F.
3/4" HOSE BIBB @ +25" A.F.F.
3/4" CW3/4" HW
UNISTRUT MOUNTING BRACKET
TYPICAL EVERY 5 FEET
3/4" ARMAFLEX
INSULATION
3/4" HOSE BIBB
CHECK VALVE
FD-1
FD-1
CHECK VALVE
NORMALLY CLOSED
SHUT-OFF VALVE
2" BYPASSBOOSTER PUMP
SHUT-OFF VALVE
UNION (TYP.)
PRESSURE GAUGE/TRANSDUCER (TYPE)
CONCRETE HOUSEKEEPING PAD
BLADDER TYPE
DIAPHRAM TANK
PR
ES
SU
R
E
BO
O
ST
ER
D
ET
AI
L
BP-1
PLUMBING ROOF PLAN - PIC/BATHROOM
SCALE: 1/4" = 1'-0"
NOTE:
ROOF DRAIN PIPE SIZED
BASED ON 2018 IPC TITLE
1106.6 AND 1" RAINFALL
2" VERTICAL GUTTER
CAN HANDLE UP TO 30
GPM.
2X2 HORIZONTAL
GUTTER CAN HANDLE UP
TO 26 GPM.
BASED ON MY
CALCULATION.
2"X2" GUTTER 2" DOWNSPOUT2" DOWNSPOUT 2"X2" GUTTER
2"X2" GUTTER 2" DOWNSPOUT2" DOWNSPOUT 2"X2" GUTTER
2" DOWNSPOUT
2"X2" GUTTER
2" DOWNSPOUT
2"X2" GUTTER
PLUMBING ROOF PLAN - COMMITTAL SHELTER
SCALE: 1/4" = 1'-0"
NOTE:
ROOF DRAIN PIPE SIZED
BASED ON 2018 IPC TITLE
1106.6 AND 1" RAINFALL
2" VERTICAL GUTTER
CAN HANDLE UP TO 30
GPM.
2X2 HORIZONTAL
GUTTER CAN HANDLE UP
TO 26 GPM.
BASED ON MY
CALCULATION.
1224/05/2023
100% CD SUBMITTAL
BID DOCUMENTS
SEE CIVIL PLANS
FOR CONTINUATION
3" V
ROOF
PENETRATION
(TYP).
2" W
4" W
MS-1
FD-1
WC-2
WC-1
WC-2
WC-1
FD-1
UR-1
L-1
EDF-1
WCO
WCO
L-1
WCO
3" W
3" W
3" V
2" V
L-1 L-1
EDF-1
L-1 L-1
HB-1
WH-1
MS-1
1-1/2" CW
3/4" CW
3/4" HW
3/4" CW
3/4" HW
1" CW
1" CW
3/4" CW
3/4" HW
3/4" HW3/4" CW
3/4" CW
BALL
VALVE
(TYP)
1-1/4" CW
3/4" HW
1-1/4" CW
DOMESTIC WATER PIPING SCHEMATIC
NTS
WASTE WATER PIPING SCHEMATIC
NTS
NOTE:
2" AND 3" WASTE PIPE
SHALL BE SLOPED 1/4"
PER FOOT.
4" WASTE PIPE SHALL BE
SLOPED 1/8" PER FOOT.
BP-1
1" CW
3/4" HW
2" W
2" V
CO
P-101
PIC/BATHROOM BUILDING PLUMBING
SCHEMATIC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\j ob s\ va el ko n at io na l c em et ar y\ 1b m ec h-pl bg \s he et s\ p-
- p lu m bi ng p la n.
dw ad av ed
:5 /2
/2
1:
lo t:5
/2 /2
1:
P M
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15795
ELKO NATIONAL CEMETERY
943-001
2/10/2023
3602 JENNINGS WAY, ELKO, NV 89801
100% CONSTRUCTION
DOCUMENTS
Date: Dwg. of 133
IRRIGATION: M.E.P.:GEOTECHNICAL :STRUCTURAL:
AST
7301 OHMS LANE, STE 215
EDINA, MN 55439
952-854-9302
MICHELLE SCHMIDT
WIM
175 JAMES AVE N.
MINNEAPOLIS, MN 55405
763-559-1010
TIM MALOOLY
TERRACON
6949 S. HIGH TECH DRIVE
MIDVALE, UT 84047
801-545-8500
JENNIFER DIERCKSEN
AESUS
1050 E. SOUTHERN AVE, STE 5
TEMPE, AZ 85282
480-454-2861
ORLANDO GONZALES 1234/05/2023
100% CD SUBMITTAL
BID DOCUMENTS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h:
z
:\j ob s\ va el ko n at io na l c em et ar y\ 1c e le ct ric al \s he et s\ e0 ge ne ra l n ot es a nd a bb re vi at io ns .d w ae su s de si gn sa ve d:
5/
3/
0:
A lo t:5 /3
/2
:2
AM
Office of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 16735
ELKO NATIONAL CEMETERY
943-001
5/5/2023
3602 JENNINGS WAY, ELKO, NV 89801
BID DOCUMENTS
Date: Dwg. of 133
BID DOCUMENTS
IRRIGATION: M.E.P.:GEOTECHNICAL :STRUCTURAL:
AST
7301 OHMS LANE, STE 215
EDINA, MN 55439
952-854-9302
MICHELLE SCHMIDT
WIM
175 JAMES AVE N.
MINNEAPOLIS, MN 55405
763-559-1010
TIM MALOOLY
TERRACON
6949 S. HIGH TECH DRIVE
MIDVALE, UT 84047
801-545-8500
JENNIFER DIERCKSEN
AESUS
1050 E. SOUTHERN AVE, STE 5
TEMPE, AZ 85282
480-454-2861
ORLANDO GONZALES
EP-001
ELECTRICAL GENERAL NOTES,
ABBREVIATIONS & SYMBOLS
1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR
ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES F0R ALL CONFIGURATIONS DETAIL ON
THIS PAGE FOR ADDITIONAL INFORMATION.
2. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE WITH
NUMBERING ONT HE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR BRANCH
CIRCUITS. BALANCE THE LOAD ON PANEL AS EVENLY AS POSSIBLE BETWEEN EACH PHASE.
3. MOUNT ALL DUPLEX RECEPTACLES OUTLETS AT +24" FROM GROUND/FLOOR (CENTERLINE
DIMENSION) EXCEPT WHERE OTHERWISE NOTED.
4. CONTRACTOR SHALL VERIFY ALL EQUIPMENT LOCATIONS WITH ARCHITECTURAL/CIVIL PLANS, ELEVATIONS, IRRIGATION PLANS, AND REVIEWED SHOP DRAWINGS. PRIOR TO MAKING THE
ACTUAL ELECTRICAL INSTALLATION, THIS CONTRACTOR SHALL ADJUST RECEPTACLES,
OUTLETS, OR CONNECTION LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.
5. ELECTRICAL EQUIPMENT SHALL BE MOUNTED TO AVOID IMPEDANCE OF, OPERATION 0F,
AND/OR ACCESS TO ELECTRICAL EQUIPMENT ALL MOUNTING OF ELECTRICAL EQUIPMENT, 0N
EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR, SHALL BE APPROVED IN ADVANCE BY THE
OTHER CONTRACTOR,
ELECTRICAL INSTALLATION NOTES:
ABBREVIATIONS
@ AT
A/C AIR CONDITIONING(ER)
A (AMP) AMPERE
AC ABOVE COUNTER, ALTERNATING
CURRENT
ADJ ADJUSTABLE
ADJT ADJACENT
AFF ABOVE FINISHED FLOOR
AIC AMPERE INTERRUPTING CAPACITY
ARCH ARCHITECT; ARCHITECTURAL
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AWG AMERICAN WIRE GAUGE
BKBD BACKBOARD
BKR BREAKER
BLDG BUILDING
C CONDUIT
CAP CAPACITY
CB CIRCUIT BREAKER
CKT CIRCUIT
CLG CEILING
CLR CLEAR
COL COLUMN
CT CURRENT TRANSFORMER
CTL CONTROL
CU COPPER
DISC SW DISCONNECT SWITCH
DISC DISCONNECT
DN DOWN
DWG DRAWING
(E) EXISTING TO REMAIN
(EL) EXISTING TO BE RELOCATED
(ER) EXISTING TO BE REMOVED
(RE) RELOCATED ITEM PER (EL)
E EAST
EC ELECTRICAL CONTRACTOR
EDH ELECTRIC DUCT HEATER
EF EXHAUST FAN
EGC EQUIPMENT GROUNDING CONDUCTOR
EL ELEVATION
ELEC ELECTRIC(AL)
EM EMERGENCY
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
ENTR ENTRANCE
EP EXPLOSION PROOF
EPO EMERGENCY POWER OFF
EQUIP/EQP EQUIPMENT
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXH EXHAUST
EXT EXTERIOR
EXIST EXISTING
F FAHRENHEIT/FUSE
FA FIRE ALARM
FAA FIRE ALARM ANNUNCIATOR
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FCU FAN COIL UNIT
FDR FEEDER
FIXT FIXTURE
FLA FULL LOAD AMPS
FSD FIRE/SMOKE DAMPER
GEC GROUNDING ELECTRODE CONDUCTOR
GEN GENERATOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
GFR GROUND FAULT RELAY
H HEIGHT
HP HORSEPOWER
HR HOUR
HT HEIGHT
HW HOT WATER
HZ HERTZ
IBC INTERNATIONAL BUILDING CODE
IC INTERCOM
IES ILLUMINATING ENGINEERING SOCIETY
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
IN INCH
JB JUNCTION BOX
KCMIL THOUSAND CIRCULAR MILLS
KVA KILOVOLT AMPERES
KVAR KILOVOLT AMPERES REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LBS POUNDS
LF LINEAR FEET (FEET)
LRA LOCKED ROTOR AMPS
LS LIFE SAFETY
LT LIGHT
LTG LIGHTING
LV LOW VOLTAGE
MAG MAGNETIC
MAN MANUAL
MAT MATERIAL
MAX MAXIMUM
MCA MINIMUM CIRCUIT AMPACITY
MCB MAIN CIRCUIT BREAKER
MECH MECHANICAL
MEZZ MEZZANINE
MG MOTOR GENERATOR
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MLO MAIN LUG ONLY
MOCP MAXIMUM OVERCURRENT
PROTECTION
MS MAGNETIC STARTER
MTD MOUNTED
MTG MOUNTING
MTR MOTOR
N NORTH; NEUTRAL
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS
ASSOCIATION
NESC NATIONAL ELECTRICAL
SAFETY CODE
NEUT NEUTRAL
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OC ON CENTER
OFCI OWNER FURNISHED
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER
INSTALLED
OL OVERLOAD
OS OPTIONAL STANDBY
P PRIMARY
PA PUBLIC ADDRESS
PAR PARALLEL
PB PULL BOX
PE PHOTO ELECTRIC
PF POWER FACTOR
PH PHASE
PHH POWER HAND-HOLE
PIV POST INDICATOR VALVE
PNL PANEL
POC POINT OF CONNECTION
PWR POWER
QTY QUANTITY
R (R) RELOCATE (D)
RAD RADIUS
RECPT RECEPTACLE
REF REFRIGERATOR
RLA RATED LOAD AMPS
S SOUTH
SC SECURITY
SCCR SHORT CIRCUIT CURRENT
RATING
SD SMOKE DETECTOR
SECT SECTION
SF SUPPLY FAN
STOR STORAGE
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
T THERMOSTAT
TC TIME CLOCK
TYP TYPICAL
UC UNDER COUNTER
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITERS
LABORATORIES
UON UNLESS OTHERWISE NOTED
UV UNIT VENTILATOR
V VOLT
VEL VELOCITY
VM VOLTMETER
W WATT, WEST
W/ WITH
W/O WITHOUT
WH WATER HEATER
WHM WATT HOUR METER
WP WEATHERPROOF
X REACTANCE
XFMR TRANSFORMER
XMTR TRANSMITTER
Z(%) IMPEDANCE
& AND
I.E.: THAT IS
E.G. FOR EXAMPLE
SYMBOLS LEGEND - WIRING DEVICES
DESCRIPTIONSYMBOL
SINGLE-POLE WALL SWITCH. MOUNT AT 48" AFF. TO TOP (PER ADA) , UON.
WALL SWITCH - SUBSCRIPT
SPECIAL PURPOSE…