This federal contract opportunity notice solicits bids for the construction of a new cemetery in Elko, Nevada. The Department of Veterans Affairs National Cemetery Administration issued solicitation number 36C78623B0029 to procure cemetery construction services under opportunity name Y1AA--PD - Elko NV 943-001 New Cemetery Construction. Bids are due by July 23, 2023 and the contract is slated for award in September 2023. The opportunity involves building a new veterans cemetery in Elko, Nevada according to plans and specifications contained in the 11MB file for bid documents and drawings. Pricing will be fixed-price and the procurement is unrestricted with no set-aside provisions.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WH
FD
FD
NOYES
APPLICABLE REGULATIONS
GENERAL TYPE OF PROJECT
NFPA NATIONAL FIRE CODES (EXCEPTION: NFPA 5000 & 900)
2018 FGI GUIDELINES
2018 NFPA 101 (LIFE SAFETY CODE)
ABA STANDARDS (2015) (ABAAS)
2018 IBC
REMODEL
ADDITION
NEW BUILDING
PROJECT DESCRIPTION
CODE SUMMARY
PIC/PUBLLIC RESTROOM W/ STORAGE SPACE
VA BARRIER FREE DESIGN STANDARD (PG-18-13)
NOYESAUTHORITIES HAVING JURISDICTION (AHJ's)
THE JOINT COMMISSION (TJC)
CENTER FOR MEDICARE/MEDICAID SERVICES (CMS)
TESTRATING (HRS)
ALLOWABLE (from above)ACTUAL
TOTAL
EXTERIOR DOORS AND WINDOWS
SHAFTS AND EXIT PASSAGEWAYS
OTHER
ROOF CONSTRUCTION
PRIME & SEC. FLOOR BEAMS, JOISTS
FLOOR/CEILING ASSEMBLY
FLOOR CONSTRUCTION
INTERIOR
NON-BEARING WALLS AND PARTITIONS
BEARING WALLS
COLUMNS
GIRDERS
TRUSSES
ROOF/CEILING ASSEMBLY
PRIME & SEC. ROOF BEAMS, JOISTS
EXTERIOR
INTERIOR BEARING WALLS
EXTERIOR BEARING WALLS
STRUCTURAL FRAME
AREA SEPARATIONS / FIRE WALLS
FIRE-RESISTIVE REQUIREMENTS
TYPE(S) OF CONSTRUCTION
ACTUAL AREA PER FLOOR
CONSTRUCTION TYPE(S)
FIRST FLOOR
ADDITIONAL NOTES
NOT APPLICABLE
PLUMBING FIXTURES
TOILETS
LAVATORIES
DRINKING FOUNTAINS
SERVICE SINKS
PROVIDED RQD FACTOR
2 M, 2 F 2 M, 1 F 1/25 for first 50 occupants, then 1/50
1/40 for first 80 occupants, then 1/80 1/100 occupants. 50% may be vending
URINALS 1 -- --
OCCUPANT LOAD OF BUILDING
SF/OCCUPANT OCCUPANTS
TOTAL BUILDING OCCUPANT LOAD:
ACTUAL AREAAREA LOCATION
FIRST LEVEL
9000 SF
1,152 GSF
0 -
(IBC CH 29)
(NFPA 220 TABLE 4.1.1) V(000)
OSHA STANDARDS
VA SEISMIC DESIGN REQUIREMENTS H-18-8
NATIONAL ELECTRIC CODE (NEC)
ASME BOILER AND PRESSURE VESSEL CODE
ASME CODE FOR PRESSURE PIPING
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE,
AMERICAN CONCRETE INSTITUTE AND COMETARY (ACI 318)
MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE
FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL
BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
ENERGY POLICY ACT OF 2005 (EPAct)
DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS
FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE
RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL
BUILDINGS, 10 CFR PARTS 433,434 AND 435
FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE
BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
EXECUTIVE ORDER 13834
THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED
IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE VA
MASTER CONSTRUCTION SPECIFICATION
VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE
STANDARD 62.1-2004
SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE
STANDARD 15 -2007
VA FIRE PROTECTION DESIGN MANUAL
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA
NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER
GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL)
16'-0"
NOYES
ALLOWABLE HEIGHTACTUAL HEIGHT
(504.2)
(Table 601, footnote d or e)
(Table 503)
(Table 503)
ONE HOUR SPRINKLER SUBST
EXTRA FLOOR/HEIGHT FOR SPRINKLER
40'-0"
STORIES
FEET
BUILDING HEIGHT
(Choose One)
(IBC Section 503)
( from table 503)
YES NO
(1 HOUR CONSTRUCTION SUBST)
(MULTIPLE STORY BUILDING)
(SINGLE STORY BUILDING)
BASIC ALLOWABLE AREA x 0
BASIC ALLOWABLE AREA x 2
BASIC ALLOWABLE AREA x 3
ALLOWABLE AREA PER FLOOR
TOTAL ALLOWABLE AREA/FLOOR
SPRINKLER INCREASE
BASIC ALLOWABLE AREA
FRONTAGE INCREASE
9000 SF
NOYES
(Section 8.3)
CHANGE OF OCCUPANCY?
SEPARATED OCCUPANCIES?
FIRE BARRIER RATING(S) NOT APPLICABLE
OCCUPANCY CLASSIFICATION(S)
OCCUPANCIES
(If Remodeling)
2018 LSC (TABLE 6.1.14.1)
(LSC CH 12-42)
NOYES
FIRE RESISTIVE CORRIDORS?
SMOKE TIGHT CORRIDORS (SMOKE PARTITIONS)
INCIDENTAL USE AREA RATING(S) NA
MISCELLANEOUS
INTERIOR FINISHES CLASSIFICATION AEXITS
B EXIT ACCESS CORRIDORS
COTHER SPACES
9000 SF
NA
NA
9000 SF 9000 SF
9000 SF
121,152/100
2 M, 2 F 2 M, 1 F
NA
BUILDING FLOOR AREA DOES NOT EXCEED
1,500 SF - IBC SECTION 903
AUTOMATIC SPRINKLER SYSTEM
AREAS OF REFUGE REQUIRED
MEANS OF EGRESS CAPACITY (12 x 0.2)
EGRESS
2.5"
NOYES
ACCESSIBLE MEANS OF EGRESS ("MOE") REQUIRED
ELEVATOR REQUIRED AS MEANS OF EGRESS
FE
34'-0"
COMMON PATH OF TRAVEL
'-0
E X
IT
A
C C
E S
S T
R A
V E
L D
IS
T
A N
C E
STORAGE
PORTICO
MENS
WOMENS
TECH
CLOSET
HAC
LIFE SAFETY SYMBOLS
SMOKE TIGHT
ASSEMBLY
1 HOUR FIRE
BARRIER
2 HOUR FIRE
BARRIER
3 HOUR FIRE
BARRIER
1 HOUR FIRE &
SMOKE BARRIER
2 HOUR FIRE &
SMOKE BARRIER
3 HOUR FIRE &
SMOKE BARRIER
HE
TRAVEL DISTANCE
100'-10"
TRAVEL DISTANCE
EA
EDEXIT EXIT
HORIZONTAL EXIT
EXIT DISCHARGE
EXIT ACCESS
FIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FEC
LIMITS OF
CONSTRUCTION
SMOKE
COMPARTMENT
BOUNDARY
HEALTH CARE
SUITE
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
OCCUPANCY
SEPARATION
SHAFT
ADJACENT SYMBOLS SHOW PARTITION RATING AND
DAMPER REQUIREMENTS
HAZARDOUS USE
ADJACENT SYMBOLS SHOW PARTITION RATING.
OPENINGS REQUIRE CLOSER & LATCH
EXIT PASSAGEWAY
RATE AS STAIR
ALL OPENINGS TO BE RATED AS STAIR SHAFT
CORRIDOR
WALLS TO LIMIT THE TRANSFER OF SMOKE
ADJUNCT CORRIDOR or PSYCHIATRIC AREA or CONSTRUCTED WITH MIN. 4'-0" CLEAR
WITH (PER CHAPTER 19)
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
Lowell Anderson
05/05/2023
19366
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
R
E S
T R
M
R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/4
/2
:2
:4
P M
1401-AE100
PIC/PUBLIC RESTROOM LIFE
SAFETY PLAN
ELKO NATIONAL CEMETERY
3602 JENNINGS WAY, ELKO, NV 89801
943-001
5/5/2023 LA JT16735
1/4" = 1'-0"
PIC/PUBLIC RESTROOM LIFE SAFETY PLAN
0 4' 8'2'
Dwg 88 of 133
PLAN
NORTH
TRUE
NORTH
Revisions: Date:
FD
AE201
AE201
AE201
AE201
AE301
AE301
AE211
'-0
8' -0
1'-6" 2'-6"
5' -4
6' -8
6'
-8
10'-0"
1'-4" 14'-2" 5'-10"
4' -2
4'
-0
8' -0
"2
'-6
5'
-4
'-6
'-0
GRAVE
LOCATOR
MENS
WOMENS
STORAGE
PORTICO
20'-8" 2'-0" 12'-8" 2'-0"
22'-8"
4' -0
"3
AE301
AE301
AE501
AE211
AE211
8' -4
TECH
CLOSET
4' -0
"4' -0
5'-6"3'-6" 1"1"2'-7 3/4"5'-6"
AE301 9
AE301
2' -0
2' -0
2'
-0
2' -0
LINE OF ROOF
OVERHANG
ABOVE
1'-0"
1'-0"
AE501
AE301
20'-8" 2'-0" 12'-8" 2'-0" 26'-8"
CONCRETE
SLAB
SIDEWALK
CONCRETE
SLAB
SIDEWALK
A3
XN3
XN3
A3
TYP
64'-0"
'-0
4' -0
'-0
1'
-4
'-0
BOOSTER
PUMP
DEDICATION
PLAQUE
AE2118
8' -2
R O
2' -3
/8
AE501
FE 8'-0"
DIAPER CHANGING STATION
DIAPER CHANGING
STATION
10"
10"
C J
C J
SAWCUT CONTROL JOINTS-
SEE CIVIL 6/CP501
C J
C J
C J
C J
CJ CJ CJ
HAC
A3
AE211
6' -0
6'
-0
4'-0"3'-1" 3'-4 1/2"
2' -1
2' -1
STORAGE
MENS
WOMENS
PORTICO
AFF9'-0"
AFF9'-0"
AFF9'-0"
AFF9'-8"
TECH
CLOSET
AFF9'-0"
PORTICO RIDGE
TONGUE AND GROOVE
WOOD BOARDS
SLOPE SLOPE
2'-0" 6'-0" 2'-0"2'-0" 2'-0" 5'-4" 2'-0" 4'-8" 2'-0" 5'-4" 2'-0" 2'-8"
2'-0" 5'-4" 2'-0" 4'-8" 2'-0" 5'-4" 2'-0" 2'-8"
HIGH WINDOW, TYP
AE501
E Q
E Q
EQ EQ
3' -0
4'-4" 3'-0"
2' -0
4'-6" 2'-4"
4'-2" 5'-2" 5'-2"
3' -4
3' -0
4'-4" 3'-0"
2' -0
4'-6" 2'-4"
4'-2" 5'-2" 5'-2"
3' -4
2'-8"
2' -8
3'X3'
ACCESS
PANEL
8'-11"
5"
1'-3 1/2"
1'-6" 2'-6" 2'-10"
1' -0
1'-6" 2'-6" 2'-10"
1' -0
2'-0" 6'-0" 2'-0" 6'-0" 2'-0"2'-0"
AE602
UNIT HEATER -
SEE MECH
WALL MOUNTED
EMERGENCY
LIGHT
CAMERA
LOCATION FOR
ADDITIONAL
NOTES AND
INFORMATION
SEE 1/ EY-102
CAMERA LOCATION FOR
ADDITIONAL NOTES AND
INFORMATION SEE 1/ EY-102
CAMERA
LOCATION FOR
ADDITIONAL
NOTES AND
INFORMATION
SEE 1/ EY-102
CAMERA
LOCATION FOR
ADDITIONAL
NOTES AND
INFORMATION
SEE 1/ EY-102
EQ EQ
E Q
E Q
EQ EQ
E
Q E
Q
HAC
AFF9'-0"
2' -0
2'
-0
2' -0
2'
-0
LED COVE
LIGHT
TERMINATE LIGHT
FIXTURE 2'-0" FROM
END OF WALL,TYP
RCP GENERAL NOTES
1. GENERAL CONTRACTOR TO COORDINATE ALL CEILING MOUNTED EQUIPMENT
SUPPORT REQUIREMENTS, LOCATIONS, DIMENSIONS, ETC WITH EQUIPMENT
SUPPLIER AND OWNER, PRIOR TO INSTALLATION.
2. ALL CEILING MOUNTED ITEMS SUCH AS LIGHT FIXTURES, GRILLES, DIFFUSERS,
SPEAKERS, EXIT LIGHTS, ETC SHALL BE LOCATED IN THE CENTER OF ACT PANELS,
GYP BD SOFFITS AND/OR PLASTER SOFFIT BAYS, UNLESS NOTED OTHERWISE.
COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS.
REFLECTED CEILING PLAN SYMBOLS
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
GYP BD
CEILING /
SOFFIT
ACT CEILING
SYSTEM
EXISTING
ACT CEILING
SYSTEM
IV TRACK
CUBICLE
CURTAIN
TRACK
ACCESS
PANEL
2'-0" x 4'-0"
LIGHT FIXTURE
2'-0" x 2'-0"
LIGHT FIXTURE
COVE LIGHT
PENDANT STRIP
LIGHT FIXTURE
RECESSED
LIGHT FIXTURE
MECHANICAL
SUPPLY GRILL
MECHANICAL
RETURN GRILL
WALL SCONCE
LIGHT FIXTURE
MECHANICAL
LINEAR SUPPLY
GRILL
CEILING
ELEVATION AND
FINISH
9'-0" AFF
ACT
GENERAL NOTES
1. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS AND LIMITS OF
CONSTRUCTION WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT.
INCIDENTAL WORK MAY BE NECESSARY IN AREAS NOT SHOWN ON ARCHITECTURAL
DRAWINGS DUE TO CHANGES AFFECTING ELECTRICAL, MECHANICAL AND PLUMBING
ALONG WITH OTHER SYSTEMS. THIS INCIDENTAL WORK SHALL BE PART OF THIS
CONTRACT, AND ALL TRADES SHALL INSPECT THESE AREAS, ASCERTAIN WORK
REQUIRED AND DO THE WORK IN ACCORDANCE OF CONTRACT REQUIREMENTS AT
NO ADDITIONAL COST.
2. CONTRACTORS SHALL VISIT THE SITE DURING BIDDING TO BECOME FAMILIAR WITH
THE EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL LOCATE, INSPECT
AND FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS PRIOR
TO DEMOLITION AND CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
3. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
4. EQUIPMENT UNIT DIMENSIONS ARE FOR PRODUCT DESCRIPTION ONLY, VERIFY SIZE
WITH MANUFACTURER.
5. ALL DIMENSIONS PERTAINING TO MECHANICAL OR ELECTRICAL SERVICES OR
EQUIPMENT SHALL BE VERIFIED WITH THE RESPECTIVE TRADE.
6. VERIFY HEIGHTS AND LOCATIONS OF ACCESS PANELS (AP) AND COORDINATE TYPES
WITH TRADES WHICH REQUIRE THEM.
7. PROVIDE LINTELS AND FRAMING FOR GRILLES, LOUVERS, AND ROOF VENTS AS
REQUIRED BY MECHANICAL CONTRACTOR, VERIFY SIZE AND LOCATION.
8. STRUCTURAL, MECHANICAL, AND ELECTRICAL ABBREVIATIONS AND SYMBOLS MAY
DIFFER FROM ARCHITECTURAL. SEE RESPECTIVE SECTIONS AND/OR DRAWINGS FOR
DEFINITIONS.
9. FOR ADDITIONAL NOTES AND INFORMATION REFER TO STRUCTURAL, MECH, ETC..
DRAWINGS.
FLOOR PLAN SYMBOLS
EXISTING WALL TO
REMAIN
WALL
EXISTING DOOR
AND FRAME TO
REMAIN
DOOR
INTERIOR
BORROWED LIGHT
101B
101A
8'-0"
DIMENSION LINE,
NOMINAL
8'-0" EXTENDED
DIMENSION LINE,
NOMINAL
AE2111A
INTERIOR
ELEVATION
INDICATOR TAG
2B
AE2O1
EXTERIOR
ELEVATION
INDICATOR TAG
1A
203 EQUIPMENT TAG
100 FLOOR SPOT
ELEVATIONWALL TAG
OFFICE
ROOM NAME AND
NUMBER AE501
1A
DETAIL REFERENCE
TAG
AE2O1
EXTERIOR SECTION
REFERENCE TAG
1A
AE2O1
INTERIOR SECTION
REFERENCE TAG
1A
KEY NOTE
A
GRIDLINE
REVISION TAG
PR01
REVISION CLOUD
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
FP10
B3
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
Lowell Anderson
05/05/2023
19366
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
R
E S
T R
M
R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/4
/2
:2
:4
P M
1401-AE111
PIC/PUBLIC RESTROOM FLOOR
PLAN & RCP
ELKO NATIONAL CEMETERY
3602 JENNINGS WAY, ELKO, NV 89801
943-001
5/5/2023 LA JT16735
1/4" = 1'-0"
FLOOR PLAN
0 4' 8'2'
Dwg 89 of 133
1/4" = 1'-0"
REFLECTED CEILING PLAN
0 4' 8'2'
PLAN
NORTH
TRUE
NORTH
PLAN
NORTH
TRUE
AE301
AE301
AE301
RIDGE
STANDING
SEAM
METAL ROOF
AE301
2' -0
2'
-0
2' -0
2'
-0
1'-0"
DASHED LINE
INDICATES EXTERIOR
FACE OF WALL BELOW
SLOPE
S
LO
P E
S
LO
P E
SLOPE
SLOPE SLOPE
AE301
GUTTER
GUTTER
AE301
METAL SNOW GUARD
TYPICAL
AE501
1'-0"
2'-0" 2'-0"
2'-0"2'-0"
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
Lowell Anderson
05/05/2023
19366
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
R
E S
T R
M
R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/4
/2
:2
:4
P M
1401-AE121
PIC/PUBLIC RESTROOM ROOF PLAN
ELKO NATIONAL CEMETERY
3602 JENNINGS WAY, ELKO, NV 89801
943-001
5/5/2023 LA JT16735
0 4' 8'2'
1/4" = 1'-0"
ROOF PLAN
Dwg 90 of 133
PLAN
NORTH
TRUE
FIRST FLOOR
100'-0"
AE301
AE301
STANDING SEAM
METAL ROOF
ROCKFACE
NATURAL STONE
VENEER
HONED
NATURAL STONE
VENEER BASE
AE301
OPEN TO BEYOND
ROCKFACE NATURAL
STONE VENEER
TO WALL
110'-0"
AE301
W1 W1 W1 W1
CJ/EJ CJ/EJ
METAL GUTTER
W1W1W1
DOWNSPOUT
BEYOND
METAL SNOW GUARD
REQUIRED AREA OF MOCKUP -
SEE SECTION 01 43 39
MOCKUP REQUIREMENTS
'-0
FIRST FLOOR
100'-0"
DOWNSPOUT SHOE
TYPICAL - SEE CIVIL
DRAWING FOR
ADDITIONAL NOTES
AND INFORMATION
HONED NATURAL STONE
VENEER PANEL BEYOND
METAL PANEL
STANDING SEAM
METAL ROOF
TO WALL
110'-0"
CJ/EJ CJ/EJ
GUTTER
DOWNSPOUT
HONED NATURAL STONE
VENEER BASE
CAMERA LOCATION FOR
ADDITIONAL NOTES AND
INFORMATION SEE 1/
EY-102
ROCKFACE
NATURAL
STONE
VENEER
FIRST FLOOR
100'-0"
AE301
AE301
OPEN TO BEYOND
STANDING SEAM
METAL ROOF
ROCKFACE
NATURAL
STONE
VENEER
HONED NATURAL
STONE VENEER
BASE
ROCKFACE NATURAL
STONE VENEER
2' -0
TO WALL
110'-0"
W1 W1 W1 W1 W1 W1
CJ/EJ CJ/EJ
METAL GUTTER
1' -0
5'
-8
DOWNSPOUT
BEYOND
METAL SNOW GUARD
FIRST FLOOR
100'-0"
ROCKFACE
NATURAL
STONE
VENEER
HONED NATURAL STONE VENEER PANEL BEYOND
HONED NATURAL STONE VENEER BASE
METAL PANEL
STANDING SEAM
METAL ROOF
AE301
TO WALL
110'-0"
CJ/EJ CJ/EJ
DOWNSPOUT SHOE
TYPICAL - SEE CIVIL
DRAWING FOR
ADDITIONAL NOTES
AND INFORMATION
CAMERA LOCATION FOR
ADDITIONAL NOTES AND
INFORMATION SEE 1/ EY-102
WALL MOUNTED PANEL
CONDENSING UNIT ON
CONCRETE PAD IN
FOREGROUND SHOWN
DASHED
EXHAUST FLUE - SEE 1/M-101
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
Lowell Anderson
05/05/2023
19366
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
R
E S
T R
M
R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/4
/2
:2
:4
P M
1401-AE201
EXTERIOR ELEVATIONS
ELKO NATIONAL CEMETERY
3602 JENNINGS WAY, ELKO, NV 89801
943-001
5/5/2023 LA JT16735
1/4" = 1'-0"1
NORTH ELEVATION
1/4" = 1'-0"2
EAST ELEVATION
1/4" = 1'-0"
SOUTH ELEVATION
1/4" = 1'-0"
WEST ELEVATION
Dwg 91 of 133Revisions: Date:
CASEWORK GENERAL NOTES
1. FULL HEIGHT STORAGE CABINETS (UNO)
- SHALL BE 2'-0" DEEP
- 2'-0" MAX DOOR WIDTH
- WARDROBE CABINETS TO BE 2'-0" DEEP
- PROVIDE (5) FIVE ADJ PLAM SHELVES
2. BASE AND WALL CABINETS (UNO)
- WALL CABINETS 1'-0" DEEP CLEAR INSIDE MINIMUM
- BASE CABINETS 2'-0" DEEP
- (1) ADJ PLAM SHELF AT 2'-0" HIGH WALL CABINETS
- (2) ADJ PLAM SHELVES AT 2'-6" HIGH WALL CABINETS, AND
- (3) ADJ PLAM SHELVES AT 3'-0" HIGH WALL CABINETS
3. SEE INTERIOR ELEVATIONS FOR PLAM FILLERS AND SLOPED TOPS.
4. WHERE FILLER STRIPS ARE REQUIRED, THEY SHALL BE EQUAL IN SIZE AT BOTH
ENDS OF CASEWORK (UNO).
5. PROVIDE LOCKS ON INDIVIDUAL DOORS AND DRAWERS WHERE INDICATED.
6. PROVIDE CONTINUOUS SEALANT AT TOP OF BACKSPLASH/SIDESPLASHES.
7. PROVIDE 1" THICK SHELVES WHERE CABINETS ARE OVER 3'-0" WIDE.
8. PROVIDE GROMMETS AT WORKSTATIONS, INCLUDING NURSE STATIONS, RECEPTION
DESKS AND OTHER WORK COUNTERS. CUT IN FIELD-PROVIDE ONE PER ELECTRICAL
DEVICE BELOW COUNTER-COORDINATE LOCATIONS WITH OWNER. COLOR TO BE
SELECTED BY ARCHITECT. SEE SPECIFICATION FOR GROMMET TYPES AND SIZES.
9. PROVIDE A 2" RADIUSED EDGE (IN PLAN) AT ALL OUTSIDE, EXPOSED COUNTERTOP
CORNERS (UNO). ALL PLAM COUNTERTOPS SHALL HAVE A 1 1/4" THICK PLAM SQUARE
EDGE NOSING (UNO)
10. ALL COUNTERTOPS ARE 2'-1" DEEP (UNO)
11. PROVIDE PLYWOOD BACKING AT ALL SOLID SURFACE COUNTERTOPS.
12. COUNTERTOP SUPPORT BRACKETS ARE PROVIDED BY THE CASEWORK SUPPLIER.
PROVIDE WALL BLOCKING AT EACH SUPPORT. SPACE AT 3'-0" OC MAX.
13. COORDINATE LOCATION OF ALL UNDERCOUNTER SUPPORT WITH OWNER
FURNISHED/OWNER INSTALLED EQUIPMENT.
14. NO EXPOSED FASTENERS ON CASEWORK (UNO)
15. ALL EXPOSED METAL CLIP ANGLES AND BRACKETS TO BE PAINTED TO MATCH
CASEWORK.
16. ALL EXPOSED AND SEMI-EXPOSED SURFACES OF CASEWORK, SHELVING, BASE,
FULL HEIGHT AND UPPER WALL CABINETS, AND FINISHED END PANELS ARE PLAM
(UNO)
17. FIELD VERIFY SPACE AVAILABLE AT CABINET LOCATIONS PRIOR TO CASEWORK
FABRICATION.
18. RETURN BACKSPLASH AT SIDEWALLS (UNO).
19. TUCK WALL COVERING BEHIND ALL BACKSPLASHES.
20. ALL CABINETS TO RECEIVE BASE SCHEDULED FOR ROOM (UNO).
21. COORDINATE ALL SWITCHES, UNDER-CABINET LIGHT FIXTURES AND
UNDERCOUNTER RECEPTACLES WITH THE ELECTRICAL CONTRACTOR.
22. PROVIDE HANGING FILE EDGE/HARDWARE WHERE FILE DRAWERS ARE INDICATED
23. PROVIDE A 1/4" GAP BETWEEN BOTTOM EDGE OF COUNTERTOP AND TOP EDGE OF
DOOR FRONTS/DOORS OF CABINETS
24. REFER TO FINISH PLAN GENERAL NOTES FOR CASEWORK FINISHES (UNO)
25. BASE AS SCHEDULED (UNO)
26. PLAM COUNTERTOPS TO RECEIVE 3mm FLAT PVC EDGE (UNO).
27. NUMBERS SHOWN BELOW BASE CABINETS AND ABOVE WALL CABINETS REFER TO
NOMINAL WIDTH DIMENSIONS, IN INCHES, FOR THAT CABINET. SEE REFERENCE
DETAILS FOR ADDITIONAL INFORMATION.
A5200
A5109B
TOILET PARTITION
A5075
A5080
PT-1 COVE BASE
PT-1 TO CEILING,
INSTALL STACKED
S-1 COUNTERTOP W/BACK
& SIDE SPLASH
M
IN
2' -3
INSULATE EXPOSED PIPES
A1066 A1066
A5109A
F1015
TOILET PARTITION
URINAL SCREEN 10
AE211
A5080
A5075
PT-1 COVE BASE
PT-1 TO CEILING, INSTALL STACKED
S-1 COUNTERTOP W/BACK
AND SIDE SPLASH
INSULATE EXPOSED PIPES
A1066 A1066
TOILET PARTITION
AE211
A5090
A5200
A5109B
TOILET PARTITION
2'-0" X 3'-0"
DEDICATION PLAQUE
4" HONED NATURAL
STONE VENEER BORDER
2' -8
3'
-8
4" 2'-0" 4"
8'-0" 2'-8"
7'-8"
ROCKFACE NATURAL
STONE VENEER
HONED NATURAL STONE
VENEER BASE
GRAVE LOCATOR
AE501
EMERGENCY LIGHT
CAMERA LOCATION FOR
ADDITIONAL NOTES AND
INFORMATION SEE 1/ EY-102
4" HONED NATURAL
STONE VENEER BORDER
4' -8
1'
-8
2'-7 1/2"RO
3'-4"
AE211
2'-0" 2'-0"
LIGHT COVE
4" ROCKFACE
NATURAL STONE
VENEER
4" HONED NATURAL
STONE VENEER
2'-0" X 3'-0"
DEDICATION PLAQUE
4" 3'
-0
4"
4" 2'-0" 4"
ROSETTE WITH
THREADED PIN
CENTER ALL TEXT TO
PLAGUE
CENTER PLAQUE IN
HONED NATURAL
STONE VENEER
NOTES:
1. SEE SPECIFICATION FOR MATERIAL, WORKMANSHIP, FINISH, COATING AND FASTENERS.
2. DEDICATION PLAQUE IS TO BE SUPPLIED AND INSTALLED BY THE CONTRACTOR.
3. DEDICATION PLAQUE: 24"X 36".
4. SUBMIT SHOP DRAWINGS.
ELEVATION SECTION
4" HONED NATURAL STONE
VENEER
DEDICATION PLAQUE
4" HONED NATURAL STONE
VENEER
8" CMU
2" RIGID INSULATION
ROSETTE THREADED PIN
4" ROCKFACE NATURAL
STONE VENEER
1/
2"
5/16" [8mm] X 10"
TOGGLE BOLT,
EXPANSION BOLT OR
APPROPRIATE ANCHORAGE, TYP2
1/ 2"
4" ROCKFACE NATURAL
STONE VENEER
WATER HEATER,
SEE MECHANICAL
MOP SINK
STAINLESS STEEL
SURROUND
BOOSTER PUMP
4' -0
4'-0"
4' -0
30"
2' -6
METAL CASEWORK
WALL
BACKING
2' -1
0"
UNDERMOUNT SINK -SEE PLUMBING
DRAWINGS
8 5/8" 1'-0 7/8" 3 1/2" FAUCET SEE PLUMBING DRAWINGS.
SOLID SURFACE APRON
2' -3
INSULATE EXPOSED PIPES
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
Lowell Anderson
05/05/2023
19366
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
R
E S
T R
M
R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/4
/2
:2
:5
P M
1401-AE211
INTERIOR ELEVATIONS
ELKO NATIONAL CEMETERY
3602 JENNINGS WAY, ELKO, NV 89801
943-001
5/5/2023 LA JT16735
1/4" = 1'-0"2
ELEVATION - STORAGE 101 - NORTH 1/4" = 1'-0"4
ELEVATION - MENS 104 - WEST
1/4" = 1'-0"
ELEVATIONS - MENS 104 - NORTH
1/4" = 1'-0"
ELEVATION - WOMENS 105 - SOUTH
1/4" = 1'-0"
ELEVATION - WOMENS 105 - WEST
1/4" = 1'-0"1
ELEVATION - STORAGE 101 - WEST
Dwg 92 of 133
1/4" = 1'-0"
ELEVATION - PORTICO
3/4" = 1'-0"
DEDICATION PLAQUE DETAIL
1/4" = 1'-0"3
ELEVATION - HAC 106 - SOUTH
Revisions: Date:
1" = 1'-0"
CABINET WITH SINK AND APRON
AE301
AE301
TO WALL
110'-0"
TO FOOTING
97'-6"
AE501
AE501
AE501
AE501
TRUSS GIRDER -
SEE STRUCTURAL
TRUSS GIRDER -
SEE STRUCTURAL
12'-8"
PARALLEL CHORD TRUSS -
SEE STRUCTURAL
OVERFRAMING
FIRST FLOOR
100'-0"
AE301
TO WALL
110'-0"
8' -1
1"
TO FOOTING
97'-6"
LIGHT COVE
2'-0"2'-0"
FIRST FLOOR
100'-0"
AE301
TO WALL
110'-0"
TO FOOTING
97'-6"
AE301
FIRST FLOOR
100'-0"
TO WALL
110'-0"
HONED NATURAL
STONE VENEER BASE
FOUNDATION WALL-
SEE STRUCTURAL
FOOTING -
SEE STRUCTURAL
2" BOARD PERIMETER
INSULATION
FLUID-APPLIED
MEMBRANE AIR
BARRIER
4" ROCKFACE
NATURAL STONE
VENEER
METAL SOFFIT
PANEL
STANDING SEAM
METAL ROOF
WOOD TRUSS
CMU BOND BEAM
2" AIR SPACE
2" RIGID INSULATION
8" CMU-
PAINTED
BATT INSULATION
R=40
1' -0
AE501
STORAGE
2"
AE301
WALL TIE @ 1'-4"
OC TYPICAL
2'-0"
FLUID-APPLIED
MEMBRANE AIR
BARRIER
FIRST FLOOR
100'-0"
TO WALL
110'-0"
HONED NATURAL
STONE VENEER
BASE
FOUNDATION WALL-
SEE STRUCTURAL
FOOTING -
SEE STRUCTURAL
4" ROCKFACE
NATURAL STONE
VENEER
CMU BOND BEAM
2" AIR SPACE
2" RIGID INSULATION
8" CMU
PAINTED
PORTICOSTORAGE
TRUSS GIRDER-
SEE STRUCTURAL
2X8 SILL PLATE
LED LIGHT
COVE
2" BOARD
PERIMETER
INSULATION
BATT
INSULATION
R=40
1' -0
WALL TIE @ 1'-4"
OC TYPICAL
PARALLEL
CHORD TRUSS
AE501
SIM
FLUID-APPLIED
MEMBRANE AIR
BARRIER
FIRST FLOOR
100'-0"
TO WALL
110'-0"
HONED NATURAL
STONE VENEER BASE
FOUNDATION WALL-
SEE STRUCTURAL
FOOTING -
SEE STRUCTURAL
4" ROCKFACE
NATURAL STONE
VENEER
TRUSS SPANNING
NORTH/SOUTH
2" AIR SPACE
2" RIGID
INSULATION
8" CMU
SST
FLASHING
METAL PANEL
FLAT SEAM
FLUID-APPLIED MEMBRANE
AIR BARRIER
3/4" PLYWOOD
2" BOARD PERIMETER
INSULATION
FLUID-APPLIED
MEMBRANE AIR
BARRIER
BATT INSULATION
R=40
AE301
1' -0
WALL TIE @ 1'-4"
OC TYPICAL
FLUID-APPLIED MEMBRANE
AIR BARRIER
FIRST FLOOR
100'-0"
TO WALL
110'-0"
HONED NATURAL
STONE VENEER BASE
FOUNDATION WALL-
SEE STRUCTURAL
FOOTING -
SEE STRUCTURAL
2" BOARD PERIMETER
INSULATION
FLUID-APPLIED
MEMBRANE AIR
BARRIER
4" ROCKFACE
NATURAL STONE
VENEER
METAL PANEL
WITH VENT
STANDING SEAM
METAL ROOF
WOOD
TRUSS
CMU BOND BEAM
2" AIR SPACE
2" RIGID INSULATION
8" CMU
BURNISHED
BATT INSULATION
R=40
AE501
AE501
AE501
RESTROOM
1' -0
WALL TIE @ 1'-4"
OC TYPICAL
FLUID-APPLIED
MEMBRANE AIR
BARRIER
METAL ROOF PANEL
UNDERLAYMENT
1/2" EXTERIOR GYP SHEATHING
RAKE CLOSURE TRIM PIECE FLASHING
BY METAL ROOF MANUFACTURER
UNCLEATED 22 GA SHEET METAL FASCIA
SLIPPED UNDERNEATH ROOFING PLIES.
PROVIDE SLOTTED HOLES AT TOP EDGE
OF FASCIA FACE FOR ATTACHMENT TO
BEAM TO ALLOW FOR EXPANSION
BREAK FORMED HORIZONTAL
STIFFENING JOINT @ MID-
POINT OF FASCIA FACE
DRIP EDGE
PREFINISHED SOFFIT PANEL
METAL WALL PANEL
3/4" PLYWOOD
LINEAR VENT
STANDING SEAM
METAL ROOF
WOOD TRUSS WITH
11 3/4" HEEL
CMU BOND BEAM
2" AIR SPACE
BATT INSULATION R=40
UNDERLAYMENT
1/2" EXTERIOR GYP SHEATHING
CLOSURE TRIM PIECE FLASHING BY
METAL ROOF MANUFACTURER
UNCLEATED 22 GA SHEET METAL
FASCIA SLIPPED UNDERNEATH
ROOFING PLIES. PROVIDE SLOTTED
HOLES AT TOP EDGE OF FASCIA FACE
FOR ATTACHMENT TO BEAM TO ALLOW
FOR EXPANSION
DRIP EDGE
3/4" PLYWOOD
FLUID-APPLIED MEMBRANE
AIR BARRIER
16 GAUGE ALUM
FLASHING WITH
DRIP
SEALANT AND BACKER
ROD
ROCKFACE NATURAL
STONE VENEER
8 MIL VAPOR RETARDER
CONT FASTEN TO
BLOCKING
ALUMINUM
PREFINISHED
SOFFIT PANEL
3" DEEP SPRAY FOAM
INSULATION
1"
METAL GUTTER
WOOD BLOCKING -
SEE STRUCTURAL
2x14 WOOD
BLOCKING -
SEE STRUCTURAL
(2) 1 1/2" DIA HOLES IN THE
2x14 WOOD BLOCKING
BETWEEN EACH TRUSS
INSULATION BAFFLE
MANUFACTURED METAL
RIDGE VENT
STANDING SEAM METAL
ROOF
1/2" EXTERIOR GYP SHEATHING
3/4" PLYWD
SHEATHING
UNDERLAYMENT
WOOD TRUSS
MIN
1 3/4"
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
Lowell Anderson
05/05/2023
19366
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
R
E S
T R
M
R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/4
/2
:2
:5
P M
1401-AE301
BUILDING SECTIONS, WALL
SECTION AND DETAILS
ELKO NATIONAL CEMETERY
3602 JENNINGS WAY, ELKO, NV 89801
943-001
5/5/2023 LA JT16735
1/4" = 1'-0"
BUILDING SECTION EAST/WEST
1/4" = 1'-0"
BUILDING SECTION @ PORTICO
1/4" = 1'-0"
BUILDING SECTION @ STORAGE
1/2" = 1'-0"
WALL SECTION
Dwg 93 of 133
1/2" = 1'-0"
WALL SECTION @ PORTICO
1/2" = 1'-0"
WALL SECTION @ END WALL
1/2" = 1'-0"
WALL SECTION @ HIGH WINDOW
1 1/2" = 1'-0"
RAKE DETAIL
1 1/2" = 1'-0"
EAVE DETAIL
1 1/2" = 1'-0"
RIDGE DETAIL
2'-0"
8" CMU
ROCKFACE NATURAL
STONE VENEER
ROCKFACE
NATURAL STONE
VENEER
AIR SPACE
2" INSULATION
8" CMU
4' -0
NATURAL STONE PANELS
ROCKFACE NATURAL
STONE VENEER
AIR SPACE
2" INSULATION
8" CMU
3/8" CONTROL
JOINT
3/8" EXPANSION JOINT
T Y
P
2' -0
GALV BREAK METAL FLASHING
GALVANIZED STEEL LINTEL 5" x 3 1/2" x 5/16" LLV WITH 8" BEARING EACH
SIDE -SEE STRUCTURAL
BACKER ROD AND
SEALANT -BOTH SIDES
CAVITY DRAIN MATERIAL
TERMINATION BAR
SELF ADHERING MODIFIED
BITUMINOUS - SEAL VAPOR TIGHT TO
TOP OF MET FLASHING
FLUID-APPLIED MEMBRANE AIR BARRIER
CLIP ATTACHED MINERAL WOOL
12 GAUGE GALVANIZED BENT
STEEL PLATE
FILL FRAME WITH SPRAY FOAM
HM FRAME AND INSUL HM DOOR
3/ 8"
8" M
IN
GALV BREAK METAL CLOSURE TRIM
2 5/8"6 3/4"
SEALANT
BOND BEAM. -SEE STRUCTURAL
ROCKFACE NATURAL STONE
VENEER
8" CMU
2" INSULATION
INSULATED HM DOOR AND FRAME
AS SCHEDULED
FACE OF CMU
BEYOND
2"X4"X1/4" GALV CONT
BENT PLATE W/ 5/8" DIA
ANCHOR AT 2'-0" OC -
TYP
2" RIGID INSULATION
FLUID APPLIED MEMBRANE
2" PERIMETER
INSULATION
CONCRETE SLAB -SEE STRUCTURAL
VAPOR BARRIER
FOUNDATION WALL -SEE STRUCTURAL
METAL THRESHOLD SET IN SEALANT BED
CONCRETE SLAB -
SEE STRUCTURAL
1'-6"
BACKER ROD AND
SEALANT -BOTH SIDES
3" DEEP SPRAY FOAM
INSULATION
BUILDING MEMBRANE
TERMINATION BAR
SELF ADHERING MODIFIED
BITUMINOUS
FILL FRAME WITH SPRAY FOAM
HM FRAME AND INSUL HM DOOR
4" M
IN
2 5/8"
ROCKFACE NATURAL
STONE VENEER
8" CMU
2" INSULATION
AIR SPACE
6 3/4"
12 GAUGE GALVANIZED BENT
STEEL PLATE
GALV BREAK METAL FLASHING
GALVANIZED STEEL LINTEL 5" x 3 1/2" x 5/16" LLV WITH 8" BEARING EACH
SIDE -SEE STRUCTURAL
LOUVERED WEEP HOLES AT 16" ON
CENTER
STAINLESS STEEL FLASHING
WITH DRIP
CAVITY DRAIN MATERIAL
TERMINATION BAR
SELF ADHERING MODIFIED
BITUMINOUS - SEAL VAPOR TIGHT TO
TOP OF MET FLASHING
FLUID-APPLIED MEMBRANE AIR BARRIER
CLIP ATTACHED MINERAL WOOL
8" M
IN
GALV BREAK METAL CLOSURE TRIM
2 5/8"
BOND BEAM. -SEE STRUCTURAL
ROCKFACE NATURAL STONE
VENEER
8" CMU
2" INSULATION
BACKER ROD AND
SEALANT
PRIMARY SEAL
BACKER ROD AND SEALANT
ALUM WINDOW SYSTEM - SEE
EXTERIOR ELEVATIONS
AND WINDOW TYPES
10'-8"12 GAUGE GALVANIZED BENT
STEEL PLATE
3" DEEP SPRAY FOAM
INSULATION
BUILDING MEMBRANE
TERMINATION BAR
SELF ADHERING MODIFIED
BITUMINOUS 4"
M
IN
PROVIDE BULLNOSE EDGE ON ALL
EXPOSED BURNISHED CMU
CORNERS
2 5/8"
ROCKFACE NATURAL
STONE VENEER
8" CMU
2" INSULATION
AIR SPACE
BACKER ROD AND
SEALANT
PRIMARY SEAL
BACKER ROD AND SEALANT
ALUM WINDOW SYSTEM - SEE
EXTERIOR ELEVATIONS
AND WINDOW TYPES
12 GAUGE GALVANIZED BENT
STEEL PLATE
BACKER ROD AND SEALANT.
PRIMARY SEAL
STEEL ANGLE -SEE
STRUCTURAL
MEMBRANE FLASHING SEAL
VAPOR TIGHT TO STEEL ANGLE.
EXTEND UP OVER GALV. PLATE
AND EXTEND BACK TO PRIMARY
SEAL
12 GAUGE GALVANIZED STEEL PLATE TO
ALIGN WITH SILL MASONRY OPENING
0.125 ALUMINUM FLASHING WITH DRIP
SEALANT
4" DEEP SPRAY FOAM INSULATION
BACKER ROD AND SEALANT
ROCKFACE NATURAL STONE VENEER
ROCKFACE NATURAL STONE
VENEER BEYOND
3'X3' ACCESS PANEL
5/8" GYP BD
CONTINUOUS COVE
LIGHT
LIGHT SHIELD
1X CEDAR BOARDS
5/8" GYP BD
4"
BATT INSULATION
R=40
9'-0"
5" 1'-3 1/2" 4"
1/2" PLYWD
3"
1"
TRUSS GIRDER - SEE
STRUCTURAL
PARALLEL CHORD
TRUSS - SEE
STRUCTURAL
/4
FIRST FLOOR
100'-0"
1' -0
HONED NATURAL STONE 6"
WIDE VENEER BASE
STAINLESS STEEL DRIP EDGE
SEAL AND ADHERE TO
FOUNDATION
THRU-WALL FLASHING
WEEP VENTS AT 16" OC
CAVITY DRAIN MATERIAL
TERMINATION BAR With
CONT SEALANT @ TOP
SEALANT
FLUID APPLIED
MEMBRANE AIR BARRIER
4" ROCKFACE NATURAL
STONE VENEER
2"
2" PERIMETER
INSULATION
CAVITY INSULATION
HORIZONTAL JOINT
REINFORCEMENT SEE
STRUCTURAL
WALL TIE
FLUID APPLIED MEMBRANE
GALV BREAK METAL FLASHING
GALVANIZED STEEL LINTEL 5" x 3 1/2" x 5/16" LLV WITH 8" BEARING EACH
SIDE -SEE STRUCTURAL
CAVITY DRAIN MATERIAL
TERMINATION BAR
SELF ADHERING MODIFIED
BITUMINOUS - SEAL VAPOR TIGHT TO
TOP OF MET FLASHING
FLUID-APPLIED MEMBRANE AIR
BARRIER
CLIP ATTACHED MINERAL
WOOL
8" M
IN
GALV BREAK METAL CLOSURE
TRIM
BOND BEAM. -SEE STRUCTURAL
ROCKFACE NATURAL STONE
VENEER
8" CMU
2" INSULATION
8'-0"
PAINT-
2X WOOD BLOCKING
1X CEDAR BOARDS
CONTINUOUS COVE
LIGHT
LIGHT SHIELD
4"
BATT INSULATION
R=40
STORAGE
BACKER ROD AND
SEALANT -BOTH SIDES
FILL FRAME WITH SPRAY FOAM
HM FRAME AND INSUL HM DOOR 2 5/8"6 3/4"
SEALANT
12 GAUGE GALVANIZED BENT
STEEL PLATE
TRUSS GIRDER - SEE
STRUCTURAL
PARALLEL CHORD
TRUSS - SEE
STRUCTURAL
/4
1X CEDAR BOARDS
5/8" GYP BD
1/2" PLYWD
GALV BREAK METAL FLASHING
GALVANIZED STEEL LINTEL 5" x 3 1/2" x 5/16" LLV WITH 8" BEARING EACH
SIDE -SEE STRUCTURAL
CAVITY DRAIN MATERIAL
TERMINATION BAR
SELF ADHERING MODIFIED
BITUMINOUS - SEAL VAPOR TIGHT TO
TOP OF MET FLASHING
FLUID-APPLIED MEMBRANE AIR
BARRIER
CLIP ATTACHED
MINERAL WOOL
8" M
IN
GALV BREAK METAL CLOSURE
TRIM
BOND BEAM. -SEE
STRUCTURAL
ROCKFACE NATURAL STONE
VENEER
8" CMU
2" INSULATION
PAINT-
PORTICO
TECH CLOSET
BACKER ROD AND
SEALANT -BOTH SIDES
SEALANT
12 GAUGE GALVANIZED BENT
STEEL PLATE
3' -9
/2
BACKER ROD AND SEALANT.
PRIMARY SEAL
STEEL ANGLE -SEE
STRUCTURAL
MEMBRANE FLASHING SEAL
VAPOR TIGHT TO STEEL ANGLE.
EXTEND UP OVER GALV. PLATE
AND EXTEND BACK TO PRIMARY
SEAL
12 GAUGE GALVANIZED STEEL PLATE TO
ALIGN WITH SILL MASONRY OPENING
4" DEEP SPRAY FOAM INSULATION
ROCKFACE NATURAL STONE VENEER
R O
BLOCKING AS REQUIRED 4" BORDER AROUND RO TO BE HONED
NATURAL STONE VENEER
GRAVESITE LOCATOR ENCLOSURE
25-1/2" AFF
BO RO
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
Lowell Anderson
05/05/2023
19366
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
R
E S
T R
M
R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/4
/2
:2
:5
P M
1401-AE501
EXTERIOR PLAN AND SECTION
DETAILS
ELKO NATIONAL CEMETERY
3602 JENNINGS WAY, ELKO, NV 89801
943-001
5/5/2023 LA JT16735
1" = 1'-0"
PLAN DETAIL @ PORTICO WING WALL
1" = 1'-0"
PLAN DETAIL @ WALL CORNER
1 1/2" = 1'-0"
SECTION DETAIL - HM DOOR FRAME HEAD AT CUT STONE AND CMU
1 1/2" = 1'-0"9
SECTION DETAIL EXTERIOR @ DOOR SILL
1 1/2" = 1'-0"
PLAN DETAIL - HM DOOR FRAME JAMB AT STONE AND CMU
1 1/2" = 1'-0"
SECTION DETAIL - HM WDW FRAME HEAD AT CUT STONE AND CMU
1 1/2" = 1'-0"
PLAN DETAIL - HM WDW FRAME JAMB AT STONE AND CMU
1 1/2" = 1'-0"10
SECTION DETAIL @ WDW SILL
1 1/2" = 1'-0"
SOFFIT DETAIL
1 1/2" = 1'-0"
SECTION DETAIL @ WALL BASE
1 1/2" = 1'-0"
SECTION DETAIL - HM DOOR FRAME HEAD AT PORTICO
Dwg 94 of 133
1 1/2" = 1'-0"11
SECTION @ GRAVESITE LOCATOR
PANEL PREFIXES
AL- ALUMINUM
CG- COILING GRILLE
CS- COILING SLATS
HM- HOLLOW METAL
OS- OVERHEAD SECTIONAL
RD3- REVOLVING DOOR 3 PANEL
RD4- REVOLVING DOOR 4 PANEL
VL- VERTICAL LIFT
WD- WOOD
AG ALL GLASS
BF BIFOLD
BFGBIFOLD GLASS
D DUTCH
DG DUTCH GLASS
DSDUTCH W/SHELF
FFLUSH
G2GLASS 2 LIGHT
G3GLASS 3 LIGHT
GFGLASS FULL
GH GLASS HALF
LF LOUVER FULL
LGHLOUVER GLASS HALF
LH LOUVER HALF
HM-GF
FRAME PREFIXES
0 FRAMED-CASED OPENING
1 DOOR ONLY
2 SIDELIGHT(S) 1 SIDE
3 SIDELIGHT(S) 1 SIDE W/HORIZONTAL
4 SIDELIGHT(S) BOTH SIDES
5 SIDELIGHT(S) BOTH SIDES W/HORIZONTAL
6 DOOR W/TRANSOM
7 DOOR W/TRANSOM W/SIDELIGHT(S) 1 SIDE
8 TRANSOM W/SIDELIGHT(S) 1 SIDE W/HORIZONTAL
9 TRANSOM W/SIDELIGHT(S) BOTH SIDES
10 TRANSOM W/SIDELIGHT(S) BOTH SIDES W/HORIZONTAL
11 FULL WIDTH TRANSOM W/SIDELIGHT(S) 1 SIDE
1X1 1 LIGHT WIDE AND 1 LIGHT HIGH
2X2 2 LIGHTS WIDE AND 2 LIGHTS HIGH
3X3 3 LIGHTS WIDE AND 3 LIGHTS HIGH
(NOTE: OTHER COMBINATIONS POSSIBLE)
OX FIXED PANEL, ACTIVE PANEL
OXO FIXED PANEL, ACTIVE PANEL, FIXED PANEL
OXX FIXED, ACTIVE, ACTIVE
OXXO FIXED, ACTIVE, ACTIVE, FIXED
OXXXXO FIXED, ACTIVE, ACTIVE, ACTIVE, ACTIVE, FIXED
HMS-2
LNV LOUVER NARROW VISION
NVNARROW VISION
NV2 NARROW VISION 2 LIGHT
NV3 NARROW VISION 3 LIGHT
NVCNARROW VISION CENTERED
RP2 RAISED PANEL 2 PANEL
RP4 RAISED PANEL 4 PANEL
RP6 RAISED PANEL 6 PANEL
RP8 RAISED PANEL 8 PANEL
VVISION
W WINDOWS (1 ROW)
WT WINDOWS THROUGHOUT
DOOR PANEL NAMING
DOOR FRAME NAMING NOTE: ACTUAL FRAMES MAY VARY FROM DESCRIPTIONS
BELOW, REFER TO FRAME TYPE ELEVATIONS
NOTE: ACTUAL PANELS MAY VARY FROM DESCRIPTIONS
BELOW, REFER TO PANEL TYPE ELEVATIONS
PANEL SUFFIXES
AL- ALUMINUM
AL-BL- ALUMINUM BORROWED LIGHT
AL-SL- ALUMINUM SLIDING
ALR- ALUMINUM REVOLVING
CW## CURTAINWALL
HMM- HOLLOW METAL MASONRY
HMM-BL- HMM BORROWED LIGHT
HMM-DE- HMM DOUBLE EGRESS
HMS- HOLLOW METAL STUD
HMS-BL- HMS BORROWED LIGHT
HMS-DE- HMS DOUBLE EGRESS
OC- OVERHEAD COILING
OS- OVERHEAD SECTIONAL
VL- VERTICAL LIFT
WD- WOOD
WD-BL- WOOD BORROWED LIGHT
WDP- WOOD POCKET
FRAME SUFFIXES
ISOMETRIC DETAIL
VERTICAL STUDS @ 2' - 0" MAX
W/ GYPSUM BD 1' - 4" W/ GYPSUM LATH &
PLASTER DOUBLE STUDS FOR SUPPORTING CONC
BACKER BOARD
PROVIDE CONTINUOUS BRACING WHEN STUDS
EXCEED 10' - 0" & ARE FINISHED BOTH SIDES
JAMB ANCHOR CLIPS 3 PER SIDE -
COORDINATE W/ HINGE REINFORCEMENT
NOTE 1:
OMIT BRACE WHEN "D" DIMENSION IS LESS THAN 2' - 0"
FOR GYP WALLBD. OR 16" FOR PLASTER PARTITION.
CRIPPLE STUD
DO NOT ANCHOR TO
BEARING STUD
GYPBD PANELS
CONTROL
JOINT
PROVIDE SOUND
DEADENING
WHERE REQ'D.
ISOMETRIC OF CONSTRUCTION JT.
SECTION A DETAIL C
JAMB ANCHORS
(FURNISHED WITH FRAME)
DETAIL D
DOUBLE STUDS
JAMB ANCHOR
SHIM AS
REQ'D
METAL
ANCHOR CLIP
METAL DOOR
FRAME
SANITARY STOP
WHERE REQ'D
SEC B
CONTROL JOINT
6" M
A X
DETAIL D
SEE DOOR SCHEDULE
VARIES
SHIM AS REQ'D
DETAIL C
V A
R
IE
S
E Q
E Q
E Q
E Q
D
RUNNER
BET.
STUDS
MTL
DOOR
FRAME
A A
1/2" MIN
1/ 2"
M
IN
SECTION B
STUDWIDTH
FRAME FACE
MINUS 3/16"
KYKC
3/ 4"
M
IN
JAMB DEPTDH
MINUS 3/16"
FRAME FACE
MINUS 3/16"3/
4"
M
IN
1/2" M
IN
5/8" M
AX
STUDWIDTH
3/ 4"
M
IN
GYPSUM
CONTROL JOINT
@ DOOR HEADS
FINISHED
FLOOR
HM-F
WIDTH
OPENING
O P
E N
IN
G
H E
IG
H
T
FINISHED
FLOOR
HMS-1 HMM-1
O P
E N
IN
G
H E
IG
H
T
WIDTH
OPENING
O P
E N
IN
G
H E
IG
H
T
WIDTH
OPENING
4"2"
FINISHED
FLOOR
2'-0"
6' -8
2'
-0
W1
1LI-1
XN3
(1 ) LAYER 5/8" GYPSUM
BOARD EACH SIDE
3 5/8" METAL STUD
FRAMING AT 16" OC
(1 ) LAYER 5/8" GYPSUM
BOARD
3 5/8" METAL STUD
FRAMING AT 16" OC
STC 46
4 7/8" 4 1/4"
A3
PARTITION GENERAL NOTES:
1. DIMENSIONS TO METAL STUD PARTITION ARE MEASURED TO FINISH FACE OF PARTITION
UNLESS NOTED OTHERWISE
2. THE DIMENSION SHOWING THE LOCATION OF A DOOR FRAME IN GYPSUM BOARD WALLS IS TO
THE INSIDE OF THE DOOR FRAME (DOOR OPENING). PROVIDE 4" TYPICAL DIMENSION IF NO
DIMENSION IS SHOWN.
3. SOUND ATTENUATING INSULATION MEANS GLASS FIBER OR MINERAL WOOL BATTS OR
BLANKETS BEARING THE UL LABEL FOR FIRE RESISTANCE. VERIFY TYPE AND DENSITY (PCF)
WITH FIRE TEST NUMBER SHOWN ON PARTITION TYPE.
4. FOR PARTITION HEIGHTS SEE PARTITION TAG LEGEND AND TAG SUBSCRIPTS ON PLANS.
5. FOR PARTITION TYPES WITH GYPSUM BOARD ON ONE SIDE ONLY, INSTALL GYPSUM BOARD
ON ROOM SIDE, UNLESS NOTED OR DETAILED OTHERWISE. FOR SHAFTWALL PARTITION
TYPES, INSTALL LINER PANEL ON NON-ACCESSIBLE SIDE, UNLESS NOTED OR DETAILED
OTHERWISE.
6. PROVIDE 1/2" DEFLECTION SPACE AT THE TOP OF STUDS AT ALL PARTITIONS EXTENDING TO
STRUCTURE, UNLESS NOTED OTHERWISE.
7. BULKHEAD FRAMING SHALL EXTEND TO UNDERSIDE OF STRUCTURE WITH DIAGONAL STUD
FRAMING BRACES AT 4'-0" ON CENTER (2 BRACES MINIMUM) WITH GYPSUM BOARD EXTENDING
6" ABOVE CEILING MINIMUM, UNLESS NOTED OTHERWISE.
8. GENERAL CONTRACTOR SHALL PROVIDE AND COORDINATE ALL IN-WALL BLOCKING FOR WALL
MOUNTED CASEWORK AND EQUIPMENT SUPPLIED BY THIS CONTRACT, OWNER FURNISHED OR
BY VENDORS. CONTRACTORS OPTION TO PROVIDE 3/4" FIRE TREATED PLYWOOD OR SHEET
METAL BLOCKING FOR WALL MOUNTED EQUIPMENT, CASEWORK, DOOR STOPS,
ACCESSORIES, ETC, UNLESS NOTED OTHERWISE.
9. IN WET AREAS SUCH AS BUT NOT LIMITED TO SHOWER, TUB, GLASS WASHING ROOMS,
SOILED UTILITY ROOMS, JANITOR CLOSETS, COMMERCIAL FOOD PROCESSING ROOMS, ETC,
USE TILE BACKER BOARD BEHIND THE CERAMIC TILE AND EXTEND TO 2'-0" BEYOND ALL SIDES
OF THE PLUMBING FIXTURE. IN DOUBLE LAYER WALLS WHERE THE TILE BACKER BOARD IS
INSTALLED OVER A BASE LAYER OF GYPSUM BOARD, APPLY A WATER BARRIER (BUILDING
WRAP) NOT A VAPOR RETARDER, OVER THE BASE LAYER OF GYPSUM BOARD. IN HIGH
HUMIDITY AREAS SUCH AS SAUNAS, STEAM ROOMS AND SWIMMING POOLS, WHERE WALLS
ARE EXPOSED TO CONSTANT MOISTURE, USE TILE BACKER BOARD BEHIND CERAMIC TILE.
1LI-1: CLEAR INSULATED (LOW-E) LAMINATED GLASS
GLAZING TYPES
VARIES
A S
S C
H E
D
METAL STUDS
GYP BD
HM FRAME
DOOR AS SCHED
2"
18 GA
NESTED STEEL
STUD LINTEL AT
HEADER
SEE PLAN FOR
PARTITION TYPE
VARIES
A S
S C
H E
D
METAL STUDS
GYP BD
HM FRAME
DOOR AS SCHED
2"
SEE PLAN FOR
PARTITION TYPE
ACCESSIBLE LAVATORY BASIN/BATHROOMS
GRAB BAR
ACCESSIBLE TOILET/WATER CLOSETS
MIN
2'-6"
WALL AT RECESS
M A
X
2' -1
0" T
O R
IM
M A
X
2' -1
0" T
O R
IM
3'-6"MIN
MAX
1'-0"
7"-9"
MIN
1'-0"
MIN
2'-0"
SIDE WALL BACK WALL
LAVATORY
HOUSEKEEPING/EVS CLOSET
UTILITY SHELF
SERVICE
RECEPTOR
WATER CONTROLS
MOP HOLDER
4' -8
ACCESSIBLE MIRROR
MOP HOLDER
CLEAR FLOOR SPACE
5'-0"MIN
1. SANITARY NAPKIN DISPOSAL. PROVIDE AT UNISEX, & WOMEN'S PATIENT BATHROOMS ONLY.
2. DISPENSERS MAY NOT BE LOCATED BEHIND GRAB BARS.
1. SEE PLAN FOR SPECIFIC LOCATION CONDITION
2. SDISD & PTC - VC
3. * KNEE CLEARANCE
4. SEE ACCESSIBLE MIRROR AT LAV FOR ADDITIONAL INFORMATION
1. UTILITY SHELF 24" LONG UNO
2. WATER CONTROLS AND SERVICE RECEPTOR - SEE MECHANICAL
1. SEE INTERIOR ELEVATIONS FOR
MIRROR SIZE
WALL AT CORNER
ACCESSIBLE SOAP AND
HAND SANITIZER DISPENSER
TO OPERATOR
O V
E R
C O
U N
T E
R
M A
X
4' -0
"M A
X
ACCESSIBLE PTD
TO TOWEL
SLOT
4' -0
"M A
X
O V
E R
C O
U N
T E
R
M A
X
1'-3 1/2"
EQ EQ
ACCESSIBLE LAV
9" M
IN
2' -1
0" T
O R
IM
M
A X
17"-25" TOE CLEARANCE
2' -3
"M A
X
8"MIN*
11"MIN*
25" MAX TO CONTROLS
ACCESSIBLE URINAL
MIN
1'-1 1/2"
M A
X
1' -5
2'-7"MIN
EQ EQ
M A
X
URINAL
SCREEN
56" @ WALL HUNG WC**
SND
1' -3
"M
IN
4' -0
"M A
X
DISPENSER OUTLET
ZONE
WC
LINE OF CLEAR
FLOOR SPACE
* AT TOILET COMPARTMENTS
** AT TOILET COMPARTMENTS AND SINGLE OCCUPANCY
PLACE HANDLE ON
OPEN SIDE
16"-18"
T O
R E
F
LE
C T
IV
E
S U
R F
A C
E
1'-4"
SANITARY NAPKIN DISPOSAL
1. SANITARY NAPKIN DISPOSAL. PROVIDE
AT UNISEX, & WOMEN'S PATIENT
BATHROOMS ONLY.
M A
X
1' -5
6' -0
3' -0
ACCESSIBLE BABY CHANGING
STATION
2' -9
TO BED HEIGHT
BOTTOM CHORD OF WOOD
TRUSS
10 MIL POLY VAPOR BARRIER
TOP OF WALL
3 5/8" 20 GAUGE STEEL STUDS
DIAGONAL STEEL STUD
BRACE @ 4'-0" OC
SEALANT BOTH SIDES
DEFLECTION
CONNECTION
3" SOUND INSULATION
SUSPENDED CEILING
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
Lowell Anderson
05/05/2023
19366
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
R
E S
T R
M
R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/4
/2
:2
:5
P M
1401-AE602
DOOR SCHEDULE, DETAILS AND
ELEVATIONS
ELKO NATIONAL CEMETERY
3602 JENNINGS WAY, ELKO, NV 89801
943-001
5/5/2023 LA JT16735
OPENING SCHEDULE
ASSOCIATED ROOMS OPENING PANEL INFORMATION FRAME INFORMATION
H D
W G
R O
U P
F
IR
E L
A B
E L
(M
IN
G A
S K
E T
E
LE
C T
R
IC
A L
S L
A B
E L
COMMENTSFROM ROOM NAME TO ROOM NAME NUMBER WIDTH HEIGHT
PANEL
TYPE
2ND
PANEL
TYPE
PANEL
GLAZING FRAME TYPE
FRAME
GLAZING
STORAGE PORTICO 101 3'-8" 7'-8" HM-F NONE HMM-1 NONE 1
STORAGE TECH CLOSET 102 3'-0" 7'-0" HM-F NONE HMS-1 NONE 3
PORTICO MENS 104 3'-0" 7'-0" HM-F NONE HMM-1 NONE 2
PORTICO WOMENS 105 3'-0" 7'-0" HM-F NONE HMM-1 NONE 2
HAC STORAGE 106 3'-0" 7'-0" HM-F NONE HMS-1 NONE 3
TYPES - PANELSTYPES - FRAMESTYPES - WINDOW
TYPES - PARTITION
HM DOOR DETAIL - HEAD
HM DOOR DETAIL - JAMB
TYPICAL MOUNTING HEIGHTS
Dwg 95 of 133
3" = 1'-0"
TOP OF PARTITION DETAIL
FD
AE211
AE211
AE211
A5080
A5075
A5075
A4995
A5080
A5075
A5075
A4995
A1066 A1066
A1066 A1066 A5200 A5200
A5090
A5200 A5200
A5090
NC-15.01
NC-14.01
NC-15.02
PORTICO
STORAGE
TECH
CLOSET
MENS
WOMENS
A5109B A5109B
A5109A
A5109A
A5109BA5109B
F1015
F1015
X001
IN-01.31
AE2118
AE211
HAC
NC-14.01
VA ACQUISITION CODE LEGEND
CONTRACTOR FURNISHED AND INSTALLED CC
VA FURNISHED - CONTRACTOR INSTALLED VC
V V
VC(CF)
VA FURNISHED AND INSTALLED
VA FURNISHED - CONTRACTOR INSTALLED WITH CONSTRUCTION FUNDS
V V(CF)VA FURNISHED - VA INSTALLED WITH CONSTRUCTION FUNDS
RRELOCATED
SEE DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL CONTRACTOR FURNISHED
AND CONTRACTOR INSTALLED (CC) EQUIPMENT NOT INDICATED ON EQUIPMENT
SCHEDULE.
1. REFER TO MATERIALS SCHEDULE FOR SPECIFIC PRODUCT SELECTION BASIS OF DESIGN
AND OTHER REQUIREMENTS.
2. FIELD FINISH VENTS, GRILLES, ACCESS PANELS, PLUG STRIP, BASEBOARD RADIATION
ENCLOSURES, ELECTRICAL PANEL BOARDS (IN FINISHED SPACES) TO MATCH SURFACE ON
WHICH THEY OCCUR UNLESS OTHERWISE INDICATED. EXCEPTION: ITEMS WITH FACTORY
WHITE FINISH, OCCURRING ON WHITE ACT OR WHITE GYPSUM BOARD CEILING SHALL NOT
BE PAINTED. STAINLESS STEEL ITEMS SHALL NOT BE PAINTED.
3. FIELD VERIFY ALL NEW CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR
TO INSTALLATION.
4. LOCATE CHANGES IN FLOOR FINISH MATERIAL UNDER CENTERLINE OF CLOSED DOOR
UNLESS OTHERWISE INDICATED.
5. PROVIDE CLEAR SILICONE SEALANT AT PERIMETER OF PLUMBING FLOOR DRAINS, CLEAN
OUTS, ETC IN RESILIENT AND CERAMIC TILE FLOORS.
6. PROVIDE SEALANT TO HORIZONTAL AND VERTICAL INTERIOR CERAMIC TILE CORNERS,
COLOR TO MATCH GROUT COLOR.
7. PROVIDE SEALANT AT JOINT BETWEEN COUNTER TOP, BACK OR SIDE SPLASH AND WALLS.
8. PROVIDE CLEAR SILICONE SEALANT AT THE BASE OF DOOR FRAME TO RESILIENT AND CT
FLOORING, TYP. SEE PLANS AND ROOM FINISH SCHEDULE FOR FLOOR FINISH LOCATIONS.
9. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED P-2, UNLESS NOTED OTHERWISE IN
THE OPENING SCHEDULE.
10. WOOD: PRE-FINISHED TO MATCH BUILDING STANDARD, REFER TO SPECIFICATION.
11. CEILING HEIGHTS AND MATERIALS/FINISHES CALLED OUT IN ROOM FINISH SCHEDULE ARE
FOR ENTIRE CEILING OR MAJORITY OF THAT ROOM, UNLESS OTHERWISE INDICATED. SEE
REFLECTED CEILING PLAN FOR CHANGES IN CEILING MATERIAL AND CEILING HEIGHT.
PAINT ALL SURFACES OF SOFFIT SAME COLOR AS INDICATED.
12. COLOR SELECTIONS ARE BASED ON USE OF PRODUCTS INDICATED IN THE MATERIALS
SCHEDULE. IF MANUFACTURERS OTHER THAN THOSE INDICATED ARE USED, ARCHITECT
MAY REVISE COLOR SELECTIONS OF OTHER FINISHES TO ENSURE PROPER COORDINATION
13. CEILING HEIGHTS ARE MEASURED FROM FINISH FLOOR
14. SEE INTERIOR ELEVATIONS FOR MORE FINISH INFO
FINISH GENERAL NOTES
NOTE: NOT ALL SYMBOLS MAY BE USED ON EACH PLAN
ACT ACOUSTICAL CEILING (TILE)
BB BURNISHED BLOCK (VV)
C POLISHED CONCRETE
CT CERAMIC TILE
GWB (SC) GYPSUM WALLBACK SYSTEMS (SPECIAL COATING)
LVT LUXURY VINYL TILE
LN LINOLEUM
P PAINT
PLAM PLASTIC LAMINATE
PT PORCELAIN TILE (FLOOR AND BASE)
RB RESILIENT BASE
RES RESINOUS EPOXY FLOORING
RES-W RESINOUS/EPOXY WALL/CEILING
RF RUBBER FLOORING
RSF RESILIENT SHEET FLOORING
RWC RIGID VINYL WALLCOVERING
S SOLID SURFACE
SC SPECIAL COATING
SD STATIC DISSIPATIVE TILE
SP SPECIAL FACED
TS TRANSITION STRIP
VWC VINYL WALLCOVERING
WSF WELDED SEAM SHEET FLOORING (HEAT WELDED WITH ROD)
INTERIORS LEGEND &
ABBREVIATIONS
MATERIAL INSTALL
DIRECTION
KEYNOTEEQUIPMENT TAG AF10
SIGN TAGNC-14.01
U-1000
SIGNAGE GENERAL NOTES
1. ALL SIGNAGE IDENTIFYING PERMANENT ROOMS SHALL COMPLY WITH 2010
STANDARD FOR ACCESSIBLE DESIGN.
2. ALL PERMANENT ROOM SIGNAGE TO HAVE TOP SECTION RAISED TEXT AND LOWER
SECTION BRAILLE. BRAILLE TO BE GRADE 2.
3. ALL SIGNS TO BE MOUNTED ON LATCH SIDE OF DOOR UNLESS NOTED OTHERWISE.
IF NO SPACE EXISTS ON LATCH SIDE MOUNT SIGN TO THE NEAREST ADJACENT
WALL. SIGNS MUST BE 2" FROM DOOR JAMB WITH 18" CLEAR FLOOR SPACE FROM
CENTER OF SIGN.
4. ALL SIGN TEXT AND NUMBERING SUBJECT TO FINAL APPROVAL BY OWNER.
5. ALL SIGNS MOUNTED TO GLASS TO HAVE GLASS BACKER.
6. SIGNS TO BE MOUNTED ACCORDING TO MANUFACTURERS INSTALLATION
INSTRUCTIONS AND MATERIALS.
7. SIGN DETAILS ARE FOR REFERENCE ONLY. ACTUAL DESIGN TO BE PROVIDED BY
THE VENDOR AND SUBJECT TO OWNER APPROVAL.
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
Lowell Anderson
05/05/2023
19366
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
R
E S
T R
M
R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/4
/2
:2
:5
P M
1401-AF600
FIRST LEVEL INTERIORS PLAN
ELKO NATIONAL CEMETERY
3602 JENNINGS WAY, ELKO, NV 89801
943-001
5/5/2023 MP CZ/MP16735
1/4" = 1'-0"
FIRST LEVEL INTERIORS PLAN
EQUIPMENT SCHEDULE
JSN # EQUIPMENT NAME
ACQUISITION
CODE QTY
A1066 MIRROR, FLOAT GLASS CC 4
A4995 TABLE, DIAPER CHANGING, WALL MOUNTED CC 2
A5075 SOAP DISPENSER CC 4
A5080 PAPER TOWEL DISPENSER CC 2
A5090 DISPENSER, SANITARY NAPKIN, SS, SURFACE MOUNTED CC 2
A5109A 36" GRAB BAR CC 2
A5109B 42" GRAB BAR CC 6
A5200 DISPENSER, TOILET TISSUE CC 4
F1015 WASTEPAPER BASKET CC 2
X001 MOP RACK CC 1
ROOM FINISH SCHEDULE
NO. NAME FLOOR FINISH BASE FINISH
WALL FINISH
CEILING FINISH REMARKSNORTH EAST SOUTH WEST
101 STORAGE LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
102 TECH CLOSET LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
104 MENS RES-1 RES-1 P-1 N/A N/A N/A GWB (P-3)
105 WOMENS RES-1 RES-1 N/A N/A P-1 N/A GWB (P-3)
106 HAC RES-1 RES-1 P-1 P-1 P-1 P-1 EXPOSED
0 4' 8'2'
Dwg 96 of 133
PLAN
NORTH
TRUE
NORTH
Revisions: Date:
10 21 13 TOILET COMPARTMENTS SCRANTON PRODUCTS HINY HIDERS PARTITIONS SHALE
ST-1 WOOD STAIN CABOT WOOD TONED STAIN AND SEALER NATURAL
P-3 PAINT SHERWIN WILLIAMS PROMAR 200 LOW VOC - FLAT SW7006 - EXTRA WHITE
P-2 PAINT SHERWIN WILLIAMS PROMAR 200 ALKYD SEMI GLOSS
SW 7504 - KEYSTONE
GRAY
09 91 00
P-1 PAINT SHERWIN WILLIAMS PROMAR 200 LOW VOC - EG SHEL SW 9166 - DRIFT OF MIST
09 67 23 RES-1 RESINOUS FLOORING SHERWIN WILLIAMS ARMORSEAL 8100 HAZE GRAY
09 65 19 LVT-1 LUXURY VINYL TILE TARKETT CONTOUR - PCCN CONCRETE 0712 SOAPSTONE 18X18
09 65 13 RB-1 RESILIENT BASE TARKETT JOHNSONITE TRADITIONAL RUBBER BASE TB1 PEPPERCORN 4"
09 51 00 ACT-1 ACOUSTIC CEILING TILE ARMSTRONG FINE FISSURED SQUARE LAY IN WHITE 2' X 2'
09 30 13 PT-1 PORCELAIN CERAMIC TILE CROSSVILLE RETRO ACTIVE 2.0 RET05 SNOW BLIND PO 4" X 12"
INSTALL: STACKED
GROUT:BOSTIK LUNAR H196
06 61 16 S-1 SOLID SURFACE DUPONT CORIAN ASH CONCRETE
SPEC NO. CODE MATERIAL MANUFACTURER STYLE COLOR SIZE REMARKS
MATERIALS SCHEDULE
MECHANICAL
ROOM
3/ 4"
3/ 4"
3/ 8"
3/ 4"
3/ 8"
1/ 4"
ROOM IDENTIFICATION - ADA/ABA STANDARD
MECHANICAL
ROOM
3/8" MIN
5/8" MIN
3/8"
3/8" MIN
APPROX 1/4"
3/8"
2" MAX
BRAILLE COPY
M A
X
2"
18" MIN CLR FLR SPACE
3" M
A
XSIGN
SIGNAGE GENERAL NOTES
1. ALL SIGNAGE IDENTIFYING PERMANENT ROOMS SHALL COMPLY WITH 2010
STANDARD FOR ACCESSIBLE DESIGN.
2. ALL PERMANENT ROOM SIGNAGE TO HAVE TOP SECTION RAISED TEXT AND LOWER
SECTION BRAILLE. BRAILLE TO BE GRADE 2.
3. ALL SIGNS TO BE MOUNTED ON LATCH SIDE OF DOOR UNLESS NOTED OTHERWISE.
IF NO SPACE EXISTS ON LATCH SIDE MOUNT SIGN TO THE NEAREST ADJACENT
WALL. SIGNS MUST BE 2" FROM DOOR JAMB WITH 18" CLEAR FLOOR SPACE FROM
CENTER OF SIGN.
4. ALL SIGN TEXT AND NUMBERING SUBJECT TO FINAL APPROVAL BY OWNER.
5. ALL SIGNS MOUNTED TO GLASS TO HAVE GLASS BACKER.
6. SIGNS TO BE MOUNTED ACCORDING TO MANUFACTURERS INSTALLATION
INSTRUCTIONS AND MATERIALS.
7. SIGN DETAILS ARE FOR REFERENCE ONLY. ACTUAL DESIGN TO BE PROVIDED BY
THE VENDOR AND SUBJECT TO OWNER APPROVAL.
RESTROOM
3/ 4"
6" 3/
4" 1"
3/ 8"
1/ 4"
3/ 8"
RESTROOM
3/ 4"
6" 3/
4" 1"
3/ 8"
1/ 4"
3/ 8"
Fire Equipment
CL
9"
9"
3/
5" 3/
4"
/1 6"
1/
4"
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Architect under the laws of the State of Minnesota.
Name:
Date:
License number:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
Office of
Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
BID DOCUMENTS
Lowell Anderson
05/05/2023
19366
C U s e rs
\j tu c h te n h a g e n
\D o c u m e n ts \1
R
E S
T R
M
R jt u c h te n h a g e n a e
-m n
.c o m
.r v t
/4
/2
:2
:5
P M
1401-AW601
WAYFINDING MESSAGE
SCHEDULES & SIGNAGE DETAILS
ELKO NATIONAL CEMETERY
3602 JENNINGS WAY, ELKO, NV 89801
943-001
5/5/2023 MP CZ/MP16735
6" = 1'-0"1
NC-14.01 PRIMARY ROOM ID
6" = 1'-0"2
SIGNAGE ADA STANDARDS
1/4" = 1'-0"
SIGN WALL ELEVATION
1/4" = 1'-0"
SIGNAGE - PLAN VIEW
6" = 1'-0"3
NC-15.01 RESTROOM ID
6" = 1'-0"4
NC-15.02 RESTROOM ID
6" = 1'-0"5
IN-01.31 FIRE EQUIPMENT
Dwg 97 of 133Revisions: Date:
SIGN MESSAGE SCHEDULE
LOCATION SIGN MESSAGE SIGN TYPE QUANTITY
105 WOMENS NC-15.02 1
104 MENS NC-15.01 1
102 TECH CLOSET NC-14.01 1
101 STORAGE NC-14.01 1
101 FIRE EQUIPMENT IN-01.31 1
106 HAC NC-14.01 1
AE201
AE201
AE201
AE201
AE201
AE201
COMMITTAL
SHELTER
(4) BENCH
8'-0"
2' -8
'-8
2' -8
SLIDER DOORS
LINE OF ROOF
OVERHANG
ABOVE
BIER 1'
-8
1 2
C
B
A
D
E
7' -4
6'
-8
6' -8
7'
-4
24'-4"
101.2
101.3 101.4
101.5
AE311
AE311
AE311
STORAGE
4' -4
AE501
AE501
AE501
2'-0" 8'-0"
CONC STOOP
CONC
STOOP
4'-0"
'-8
CONC
STOOP
CONC STOOP
4' -0
8'-0"
NOTE: FOR ADDITIONAL
INFORMATION ON SITE
SIDEWALK/PAVING SEE CIVIL
ENGINEERING DRAWINGS
14'-0"
12'-0"7'-0"
10'-0"
9'-0"
AE111
1' -0
'-0
26'-0"
4' -1
1"
DOWNSPOUT DOWNSPOUT
8'-0" 7'-4"
4' -0
4'-0"
'-8
8'
-8
TONGUE AND GROOVE
1X CEDAR BOARDS
1 2
C
B
A
D
E
SLOPESLOPE
SPEAKER SPEAKER
AE201
AE201 STANDING SEAM
METAL ROOF
RIDGE
ROOF SLOPE
6:12
DASHED LINE
INDICATES EXTERIOR
FACE OF WALL BELOW
1 2
C
B
A
D
E
TYP
2'-0"
T Y
P
2' -0
EPDM ON 3/4" PLYWD ON
WOOD FRAMING
S
LO
P E
ROOF SLOPE
6:12
8"
4"
GUTTER
GUTTER
1/
3' -0
3'
-0
2'-10" 2'-10"
METAL SNOW GUARD
TYPICAL
GENERAL NOTES
1. THE ARCHITECTURAL DRAWINGS SHOW PRINCIPAL AREAS AND LIMITS OF
CONSTRUCTION WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT.
INCIDENTAL WORK MAY BE NECESSARY IN AREAS NOT SHOWN ON ARCHITECTURAL
DRAWINGS DUE TO CHANGES AFFECTING ELECTRICAL, MECHANICAL AND PLUMBING
ALONG WITH OTHER SYSTEMS. THIS INCIDENTAL WORK SHALL BE PART OF THIS
CONTRACT, AND ALL TRADES SHALL INSPECT THESE AREAS, ASCERTAIN WORK
REQUIRED AND DO THE WORK IN ACCORDANCE OF CONTRACT REQUIREMENTS AT
NO ADDITIONAL COST.
2. CONTRACTORS SHALL VISIT THE SITE DURING BIDDING TO BECOME FAMILIAR WITH
THE EXISTING CONDITIONS. THE GENERAL CONTRACTOR SHALL LOCATE, INSPECT
AND FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS PRIOR
TO DEMOLITION AND CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
3. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT…