23-ATTACHMENT - BID DRAWINGS.pdf
PDF 11 MB Posted
- Attached to
- 3rd and Spruce Warehouse Improvements Project
- Solicitation number
- 2025-IFB-054
- Issued by
- Berks County, Reese CDP, Pennsylvania
About this file
This file contains bid drawings for the Spruce Street Warehouse Renovation project for the City of Reading, Pennsylvania, located at 301 South 3rd Street, Reading, PA 19602. The project involves comprehensive renovation and improvement work including demolition of existing structures, installation of new roofing systems, construction of new concrete masonry unit (CMU) partitions, installation of mechanical and electrical systems, and site improvements. The drawings are issued for bid and were prepared by Buchart Horn, Inc., with a project number of 81083-17 and an issue date of July 8, 2024. The architectural, mechanical, and electrical scope includes removal of existing wood stud partitions, doors, frames, concrete slabs, roofing materials, and roof structures; installation of new sloped steel joists and metal roof decking with mechanically fastened rigid insulation and adhered membrane roofing; new chain-link fencing and gates; new CMU infill walls matching existing coursing and bond; new exhaust fans, roof hoods, and electric unit heaters; and new electrical distribution, lighting, receptacles, and related systems.
The drawings encompass general architectural plans including demolition floor and roof plans, new construction floor plans, roof framing plans, exterior elevations, building sections and details, door and room finish schedules, and signage details. Mechanical drawings detail exhaust fan and roof hood installations with specific equipment specifications including Greenheck roof ventilators and control dampers. Electrical drawings include symbol legends, abbreviations, mounting height standards, an electrical plan with one-line diagram showing utility 240/120V single-phase service, grounding details including a grounding triad system, and details for occupancy sensor controls. The work requires contractor verification of all existing conditions and dimensions, coordination with the City of Reading throughout construction, performance of hazardous material testing and abatement prior to demolition, and maintenance of access to the Recreation Center storage room. New materials must match existing materials and finishes where required, and all systems must comply with applicable codes and manufacturer specifications.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET NO SHEET TITLE
DRAWING INDEX
GENERAL
G-001 COVER SHEET
SHEET NO SHEET TITLE
ARCHITECTURAL
ABBREVIATIONS
A.C. ASBESTOS ABATEMENT CONTRACTOR
ABV ABOVE
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADJUST ADJUSTABLE
A.F.F. ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
BH BULKHEAD
BLKG BLOCKING
B.O. BOTTOM OF
CAB CABINET
CJ CONTROL JOINT
CLG CEILING
CLO CLOSET
CLR CLEAR(ANCE)
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS OR CONTINUE
COORD COORDINATE
CORR CORRIDOR
CPT CARPET
CSWK CASEWORK
CT CERAMIC TILE
D DEEP, DEPTH
DEMO DEMOLITION
D.F. DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DWG DRAWING
E.C. ELECTRICAL CONTRACTOR
ELEC ELECTRIC (AL)
ELEV ELEVATION
EQ EQUAL
EQUIP EQUIPMENT
EX EXISTING
EXT EXTERIOR
E.W.C. ELECTRIC WATER COOLER
F.D. FLOOR DRAIN
FIN FINISH(ED)
FIXT FIXTURE
FLR FLOOR
GA GAGE, GAUGE
GALV GALVANIZED
GB GRAB BAR
G.C. GENERAL CONTRACTOR
GWB GYPSUM WALL BOARD
H HEIGHT, HIGH
H.C. HANDICAPPED
HDW HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HR HOUR
HVAC HEATING, VENTILATING,
& AIR CONDITIONING
JAN JANITOR, JANITOR'S CLOSET
L LONG, LENGTH
LAV LAVATORY
LVR LOUVER
MARB MARBLE
MAX MAXIMUM
MAT MATERIAL
M.B. MARKER BOARD
M.C. MECHANICAL CONTRACTOR
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
M.O. MASONRY OPENING
MTD MOUNTED
MTL METAL
N/A NOT APPLICABLE
N.I.C. NOT IN CONTRACT
NO NUMBER
N.T.S. NOT TO SCALE
O.C. ON CENTER
OPNG OPENING
P.C. PLUMBING CONTRACTOR
PLAS PLASTER
P.LAM PLASTIC LAMINATE
PLBG PLUMBING
PT PAINT(ED)
PTTN PARTITION
Q.T. QUARRY TILE
RB RUBBER BASE
R.C.P. REFLECTED CEILING PLAN
REV REVISION
RM ROOM
SF SQUARE FOOT (FEET)
SGFT STRUCTURAL GLAZED FACING TILE
SIM SIMILAR
SPEC SPECIFICATION
S/STL STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STR STAIR
T.B. TACK BOARD
TEMP TEMPERED
TERR TERRAZZO
THICK THICKNESS
THRESH THRESHOLD
TLT TOILET
T.M.E. TO MATCH EXISTING
T.O.S. TOP OF STEEL
TYP TYPICAL
VCT VINYL COMPOSITION TILE
V.I.F. VERIFY IN FIELD
W WIDE, WIDTH
W/ WITH
W/O WITHOUT
WD WOOD
@ AT
℄ CENTER LINE
Ø DIAMETER
° DEGREE
# NUMBER
VICINITY MAP
SITE LOCATION MAP
NO
RT
H
NO
RT
H
Name
ACT
A.3
Elevation
STRUCTURAL COLUMN
GRID LINE & TAG
TYPE
PARTITION TAG
HEIGHT
ELEVATION DATUM
DOOR TAG
CEILING TAG
KEYNOTE
REVISION SEQUENCE
NUMBER
SECTION/
EXTERIOR
ELEVATION
REFERENCE
INTERIOR
ELEVATION
REFERENCE
DETAIL /
CALLOUT
REFERENCE
Name Elevation
XX
ROOM NAME
RM #
VIEW REF
SHEET REF
VIEW REF
SHEET REF
A-201
A A-201
A
A-101
GRAPHIC SYMBOLS
ROOM TAG
10'-0"
VIEW REF
SHEET REF
PROJECT
SITE
G-001
COVER SHEET
ALH
ALH
THE CITY OF READING
FOR
OF
RENOVATION
SPRUCE STREET WAREHOUSE
301 SOUTH 3RD STREET, READING, PA 19602
PROJECT
SITEA-101 FLOOR AND ROOF DEMOLITION PLANS
A-102 FLOOR PLAN, ROOF PLAN, AND ROOF FRAMING PLAN
A-201 EXTERIOR ELEVATIONS, WALLS SECTION AND DETAILS
A-601 DOOR & ROOM FINISH SCHEDULES, DOOR & FRAME TYPES & DETAILS
E-101 ELECTRICAL PLAN AND ONE LINE
A-301 BUILDING SECTIONS AND DETAILS
MECHANICAL
M-101 FLOOR PLAN - MECHANICAL
ISSUED FOR BIDJ:\
PR
OJ
\81
3-
\08
-C
AD
D\
-G
EN
ER
AL
\81
7_
0_ G-
1 C
OV
ER
S
HE
ET
.D
W G/
Pl ot/
7/1 0/2
4 9
:56 A
M/ Jo vic ev ic, Is me ta
PROJECT NO:
CHECKED BY:
ISSUED DATE:
SHEET NO:
DRAWN BY:
© BUCHART HORN, INC.
MA
RK
IS
SU
ED
D
AT
E
DE
SC
RI
PT
IO
N
RE
VI
SI
ON
S
SHEET TITLE:
81083-17
SP
RU
CE
S
TR
EE
T W
AR
HO
US
E
RE
NO
VA
TI
ON
1 S
OU
TH
3R
D
ST
RE
ET
RE
AD
IN
G, P A, FO
R
TH
E
CI
TY
O F
RE
AD
IN
G
07/08/24
E-501 ELECTRICAL DETAILS AND SCHEDULES
ELECTRICAL
E-001 ELECTRICAL SYMBOL LEGEND
E-002 ELECTRICAL ABBREVIATIONS
X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
EX. STONE / GRASS PARKING LOT
REC. CENTER
STORAGE
STORAGE
STORAGE
EX. CONCRETE
WALK
EX
. C
ON
CR
ET
E
W
AL
K
EX. CONCRETE
WALK
X
X X
X X
X X
X
X
X
X X
XX X
X
X
X
X
X X
X X
EX. CONCRETE
WALK
3 2
10 10
ADJACENT BUILDING
ADJACENT BUILDING
(NO WORK)
(NO WORK)
(NO WORK) (NO WORK)
(N O
W
OR
K)
EXISTING PARTIAL
HEIGHT CMU WALL TO
REMAIN (APPROX. 5'-8" H.)
EXISTING CHAIN LINK
FENCE TO REMAIN
EXISTING TREES
TO REMAIN
EXISTING CMU
WALL TO REMAIN
17 17
EXISTING ROLL-UP
DOOR TO REMAIN
EXISTING SCUPPER
DRAIN TO REMAIN
EXISTING MEMBRANE
ROOFING TO REMAIN
EXISTING DOWNSPOUT
TO REMAIN
EXIST.
TERRACOTTA
COPING TO
REMAIN
ADJACENT BUILDING
DEMOLITION PLAN GENERAL NOTESDEMOLITION PLAN KEY NOTES
A. THESE DRAWINGS ARE FOR DESIGN INTENT AND DO NOT NECESSARILY INDICATE ALL EXISTING
CONDITIONS, AND/ OR ELEMENTS TO BE REMOVED. CONTRACTOR SHALL FIELD VERIFY EXISTING
ELEMENTS, DIMENSIONS, CONDITIONS, ETC.
B. DASHED ITEMS INDICATES TYPICAL WALLS, DOORS, FIXTURES, EQUIPMENT, ETC. TO BE
REMOVED, WITH OR WITHOUT KEYNOTE TAG.
C. REFER TO MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION WORK BY
OTHERS.
D. EACH RESPECTIVE PRIME CONTRACTOR SHALL PATCH AND REPAIR SURFACES DISTURBED OR
DAMAGED DURING THEIR RESPECTIVE DEMOLITION WORK TO MATCH EXISTING ADJACENT
MATERIALS AND AS REQUIRED TO RECEIVE NEW SCHEDULED FINISHES.
E. G.C TO PATCH AND REPAIR ALL EXISTING SURFACES AS REQUIRED TO RECEIVE NEW MATERIALS
AND FINISHES AS SCHEDULED.
F. EXISTING MASONRY OPENINGS BEING CLOSED OR NEW WORK AT EXISTING MASONRY WALLS
SHALL HAVE NEW WORK TOOTHED INTO EXISTING U.N.O.
G. EXISTING BUILDING ELEMENTS THAT INTERFERE WITH THE CONSTRUCTION OF THE NEW WORK
SHALL BE SELECTIVELY DEMOLISHED AND REBUILT TO MATCH EXISTING CONDITIONS AND
FINISHES.
H. ANY FIXED EQUIPMENT IN THE WORK AREAS THAT THE OWNER DOES NOT WISH TO KEEP MUST
BE PROPERLY DISPOSED OF BY CONTRACTOR AT NO ADDITIONAL COST.
I. REC. CENTER STORAGE ROOM WHICH DOES NOT REQUIRE ANY WORK UNDER THIS PROJECT
WILL BE USED BY THE CITY THROUGHOUT CONSTRUCTION. CONTRACTORS SHALL MAINTAIN
ACCESS TO THIS PORTION OF THE EXISTING BUILDING.
J. CONTRACTOR SHALL HAVE ANY TEMPORARY INTERRUPTION AND/OR RELOCATION OF
SERVICES/UTILITIES SCHEDULED AND APPROVED BY THE CITY PRIOR TO START OF WORK.
K. CONTRACTOR SHALL PERFORM HAZARDOUS MATERIAL TESTING AND ABATEMENT PRIOR TO
DEMOLITION WORK. SEE SPECIFICATIONS AND BID FORM FOR ALLOWANCES.
1. REMOVE EXISTING WOOD STUD PARTITION.
2. REMOVE EXISTING DOOR AND FRAME.
3. REMOVE EXISTING OVERHEAD DOOR AND FRAME.
4. REMOVE EXISTING CONCRETE RAMP. PATCH AND REPAIR EXISTING CONCRETE FLOOR SLAB TO
MATCH EXISTING.
5. REMOVE EXISTING ASBESTOS TILE FLOORING.
6. REMOVE EXISTING VCT FLOORING..
7. REMOVE EXISTING WINDOWS / AND / OR INFILL AT EXISTING MASONRY OPENING.
8. REMOVE EXISTING CONCRETE FLOOR SLAB AND STONE BASE IN IT'S ENTIRETY.
9. REMOVE EXISTING ROOFING AND ROOF STRUCTURE IN IT'S ENTIRETY.
10. REMOVE EXISTING CHAIN LINK FENCE AND GATES.
11. REMOVE EXISTING TREE. GRIND STUMP, REMOVE GRINDINGS, AND PROVIDE COMPACTED FILL.
12. REMOVE EXISTING STONE/SOIL TO A DEPTH OF 8" FOR ENTIRE AREA TO RECEIVE NEW
COMPACTED STONE PARKING LOT.
13. REMOVE EXISTING METAL FLOOR GRATE.
14. REMOVE EXISTING METAL LADDER DOWN TO PIT FLOOR BELOW.
15. BREAK UP CONCRETE FLOOR OF PIT BELOW AND REMOVE TOP PORTON OF PIT WALLS DOWN TO
APPROXIMATELY 24" BELOW FLOOR ABOVE. FIELD VERIFY EXTENT OF PIT. PROVIDE NEW
COMPACTED FILL.
16. REMOVE EXISTING CMU WALL DOWN TO APPROXIMATELY 24" BELOW FINISHED FLOOR.
17. REMOVE PORTION OF EXISTING CMU WALL DOWN TO APPROXIMATELY 5'-8" A.F.F. TO MATCH
HEIGHT OF EXISTING SCREEN WALL TO REMAIN.
18. REMOVE EXISTING VENT THRU ROOF.
19. REMOVE EXISTING MEMBRANE ROOFING, INSULATION IF OCCURS, WOOD ROOF SHEATHING, AND
WOOD ROOF JOISTS. EXISTING STEEL SUPPORT BEAMS TO REMAIN.
20. REMOVE EXISTING GUTTER AND DOWNSPOUT.
21. REMOVE EXISTING WOOD SHELVING.
22. REMOVE TOP PORTION OF EXISTING CMU WALL THAT IS ABOVE ROOF OF BUILDING TO REMAIN.
23. SAWCUT AND REMOVE PORTION OF EXISTING CONCRETE SIDEWALK.
24. REMOVE PORTION OF EXISTING CMU WALL AR REQUIRED FOR NEW OVERHEAD DOOR.
SCALE: 1/8" = 1'-0" 0 16'8'4'
FLOOR PLAN - DEMOLITION1
SCALE: 1/8" = 1'-0" 0 16'8'4'
ROOF PLAN - DEMOLITION2
A-101
FLOOR AND
ROOF
DEMOLITION
PLANS
IJ
AH
N
E
S
W
PROJECT NORTH
N
E
S
W
PROJECT NORTH ISSUED FOR BIDJ:\
PR
OJ
\81
3-
\08
-C
AD
D\
-A
RC
HI
TE
CT
UR
AL
\A
-1
_D
EM
O_
PL
AN
.D
W G/
La yo ut1 /7/
/20
9:
A
M/ Jo vic ev ic, Is me ta
PROJECT NO:
CHECKED BY:
ISSUED DATE:
SHEET NO:
DRAWN BY:
© BUCHART HORN, INC.
MA
RK
IS
SU
ED
D
AT
E
DE
SC
RI
PT
IO
N
RE
VI
SI
ON
S
SHEET TITLE:
81083-17
SP
RU
CE
S
TR
EE
T W
AR
HO
US
E
RE
NO
VA
TI
ON
1 S
OU
TH
3R
D
ST
RE
ET
RE
AD
IN
G, P A, FO
R
TH
E
CI
TY
O F
RE
AD
IN
G
07/08/24
X X X X X X X X X X X X X X X X X X X X X X X
REC. CENTER
STORAGE
EX. CONCRETE
WALK
EX
. C
ON
CR
ET
E
W
AL
K
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X X
X
X
X X
X
XX
X
X
X
X
X
X
X X
X X
X
X X
X X
X
X
X
X
X
EX. CONCRETE
WALK
XX
EX. CONCRETE
WALK
9'- 0"
'-4
STORAGE
TOILET
STORAGE BSTORAGE A
380 SF 570 SF
29'-6"±5'-6"+/-20'-1" +/-
A-301
STONE PARKING LOT
SEE DETAIL A/A-102
A-301
16'-0" VEHICLE GATE
3'-0" SWING GATE
A-201
A-201
9'- 0"
A-301
A-301
A-201
A-201
8A A-201
A-201
8A A-201
METAL COPING
METAL COPING
CORRIDOR
575 SF
F.E.
(N.I.C.)
F.E.
(N.I.C.)
A-201
ADJACENT BUILDING
(NO WORK)
(NO WORK) (NO WORK)
EXISTING CHAIN LINK
FENCE TO REMAIN
EXISTING TREES
TO REMAIN
EXISTING CMU
WALL TO REMAIN
(NO WORK)
EX. PARTIAL HT. CMU WALL TO REMAIN (APPROX. 5'-8" H.)
(N O
W
OR
K)
101A
STAINLESS STEEL
CLAMPING RING
PRE-MOULDED
PIPE BOOT
WATER CUT-OFF
MASTIC
ADHERED MEMBRANE
ROOFING ON 1/2"
COVER BOARD
METAL ROOF DECK
VENT PIPE
RIGID ROOF INSULATION
COMPACTED SUBGRADE
8" NO.2A MODIFIED COMPACTED
B A-102
EXISTING MEMBRANE
ROOFING TO REMAIN
V(E)
EXIST.
TERRACOTTA
COPING
E A-301
A A-301
F A-301
C A-301
D A-301
MET. GUTTERMET. D.S.
ADHERED MEMBRANE ROOFING ON
1/2" COVER BOARD ON RIGID ROOF
INSULATION VAPOR BARRIER ON
SLOPED METAL DECK
ADJACENT BUILDING
EXHAUST FAN
BY H.C.
ROOF
HOOD BY H.C.
L5 x 3-1/2 x 3/8 (LLV)
ANCHORED TO EX. CMU
WALLS WITH 3/4" DIA.
SLEEVE ANCHORS @ 16"
O.C. (TYP. EA. END WALL)
'-1
1"
(V
IF
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
K1
7"x 7"x 12" BEARING PLATE WITH (2)
2" DIA x 6" LONG HEADED STUDS SET IN 16"W x 16"D GROUT BED
(TYP. AT EA. JOIST SEAT)
10 SPACES @ 5'-0" = 50'-0"
EXISTING W18X BEAM EXISTING W12X BEAM
2'-6" ±2'-6" ±
1-1/2" 22 GA. GALVANIZED
TYPE B METAL ROOF DECK
ADJACENT BUILDING
'-5
VI
F)
SCALE: 1/8" = 1'-0" 0 16'8'4'
FLOOR PLAN1
SCALE: 1/8" = 1'-0" 0 16'8'4'
ROOF PLAN2
- INDICATES EXISTING PARTITIONS OR EQUIPMENT TO REMAINA.
B.
C. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO THE
START OF ANY WORK.
D. DO NOT SCALE THE DRAWINGS. IF DIMENSIONAL INFORMATION NOT SHOWN IS REQUIRED,
CONTACT THE ARCHITECT.
E. ALL DIMENSIONS OF WALLS OR PARTITIONS ON THE FLOOR PLANS ARE TO FACE OF NEW
CMU, OR FACE OF EXISTING WALL OR PARTITION, AND ARE NOMINAL.
F. NEW MASONRY SHALL MATCH EXISTING COURSING.
G. SEE SHEET A-101 FOR DEMOLITION WORK.
- INDICATES NEW CMU PARTITIONS
ROOF PLAN GENERAL NOTES
ROOF PLAN LEGEND
A. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS PRIOR TO PROCEEDING WITH THE WORK.
B. AT REROOFING AREA, REMOVE EXISTING METAL GUTTER, DOWNSPOUT, FASCIA, MEMBRANE
ROOFING, MEMBRANE FLASHINGS AND METAL COUNTERFLASHINGS AT WALLS/PARAPET
WALLS, RIGID ROOF INSULATION (IF OCCURS - NOT KNOWN), EXISTING WOOD ROOF DECK AND
WOOD ROOF JOISTS. INSTALL NEW SLOPING STEEL JOISTS AND METAL DECK AS DETAILED,
VAPOR BARRIER, MECHANICALLY FASTENED RIGID INSULATION (5-1/2" R-30 MINIMUM U.N.O., MULTIPLE LAYERS, STAGGERED JOINTS), MECHANICALLY FASTENED 1/2" COVER BOARD, ADHERED MEMBRANE ROOFING, AND ADHERED MEMBRANE FLASHINGS. INSTALL NEW METAL
FASCIA IN SIZES AS REQUIRED, METAL GUTTER AND DOWNSPOUT. PROVIDE NEW SURFACE
MOUNTED TWO-PIECE METAL COUNTER-FLASHING AT WALL FLASHING LOCATIONS WHERE
DETAILED.
C. ROOFING MATERIALS AND ACCESSORIES SHALL BE INSTALLED PER ROOFING
MANUFACTURER'S REQUIREMENTS.
D. PROVIDE FLASHING AT ALL ROOFING TERMINATIONS AND PENETRATIONS PER ROOFING
MANUFACTURER'S REQUIREMENTS.
E. ANY WOOD ROOF BLOCKING REQUIRED BY THE ROOFING MANUFACTURER FOR WARRANTY
SHALL BE PROVIDED BY THE G.C. AT NO ADDED COST.
F. NEW METAL COPINGS, FASCIA, GUTTERS, AND DOWNSPOUTS SHALL BE FACTORY FINISHED IN
COLOR TO BE SELECTED BY THE ARCHITECT. NEW METAL COPINGS SHALL HAVE FACTORY
MITERED/WELDED CORNERS.
- AREA OF REROOFING
- DIRECTION OF NEW SLOPED METAL ROOF DECK
V(E) - EXISTING VENT PIPE
SCALE: 1" = 1'-0" 1' 2'0 6"
VENT PIPE DETAILB
FLOOR PLAN KEY NOTES
1. INFILL EXISTING OPENING IN EXISTING CMU WALL WITH NEW CMU TO MATCH EXISTING
THICKNESS, COURSING, AND BOND (TOOTH-IN). PARGE EXTERIOR FACE TO MATCH EXISTING AND
PAINT.
2. FULL HEIGHT CHAIN-LINK FENCE TO UNDERSIDE OF ROOF JOISTS.
3. 3'-0" WIDE CHAIN-LINK SWING GATE.
4. PATCH AND REPAIR EXISTING CONCRETE SLAB.
SCALE: 1/8" = 1'-0" 0 16'8'4'
ROOF FRAMING PLAN3 NOT TO SCALE
STONE PAVING DETAILA
N
E
S
W
PROJECT NORTH
N
E
S
W
PROJECT NORTH
N
E
S
W
PROJECT NORTH
A-102
FLOOR PLAN,
ROOF PLAN,
AND ROOF
FRAMING PLAN
IJ
AH
ISSUED FOR BIDJ:\
PR
OJ
\81
3-
\08
-C
AD
D\
-A
RC
HI
TE
CT
UR
AL
\A
-1
_F
LO
OR
_P
LA
N_
NE
W
W
OR
K.
DW
G/ La yo ut1
/7/
/20
2:
P M/
Jo vic ev ic, Is me ta
PROJECT NO:
CHECKED BY:
ISSUED DATE:
SHEET NO:
DRAWN BY:
© BUCHART HORN, INC.
MA
RK
IS
SU
ED
D
AT
E
DE
SC
RI
PT
IO
N
RE
VI
SI
ON
S
SHEET TITLE:
81083-17
SP
RU
CE
S
TR
EE
T W
AR
HO
US
E
RE
NO
VA
TI
ON
1 S
OU
TH
3R
D
ST
RE
ET
RE
AD
IN
G, P A, FO
R
TH
E
CI
TY
O F
RE
AD
IN
G
FLOOR PLAN GENERAL NOTES
STORAGE
STORAGE
B101
8'- 0"
11 7
1717 17
EXISTING BUILDING BEYOND
EXISTING BUILDING BEYOND
H.P. OF
ROOF BEYOND
101A
STORAGE101
5'- 8"
MA
TC
H
EX
A-201
8A A-201 12
1 EXCAVATE AND BACKFILL TO
PROVIDE MEMBRANE
WATERPROOFING WHERE FIN.
FLOOR IS BELOW FIN. GRADE
A-201
A-201
8A A-201
5'- 8"
EXISTING BUILDING BEYOND
STORAGE
A-201
12 12
EXCAVATE AND BACKFILL TO
PROVIDE MEMBRANE WATERPROOFING
WHERE FIN. FLOOR IS BELOW FIN. GRADE
5'- 8"
EXISTING CMU WALL
(PAINT SIDE OF WALL
FACING WAREHOUSE
PROPERTY)
5'- 8"
EXISTING CMU WALL
(PAINT)
FACE OF ADJACENT
EXISTING BUILDING
AT 8A REMOVE PORTION OF EXISTING
CMU WALL TO 5'-8" A.F.F.± TO MATCH
EXISTING CMU SCREEN WALL HEIGHT.
SEE DEMOLITION PLAN
METAL COUNTER-FLASHING
MEMBRANE FLASHING
4"
COPING COVER
CONTINUOUS 20 GA
GALVANIZED CLEAT
COPING COVER
MEMBRANE FLASHING
4"
8A A-201
8A A-201
5'- 8"
MA
TC
H
EX
IS
TI
NG
5'- 8"
MA
TC
H
EX
IS
TI
NG
REMOVE EXISTING
CMU PIER BEYOND
REC. CENTER
STORAGE
PAINT EXISTNG HM
DOOR AND FRAME
1'-0"
10'-0"
8'- 0"
2" x2
" C
HA
IN
LI
NK
VI
NY
L C
OA
TE
D W
IR
E
FA
BR
IC
3" 3'-
6"
1 5 8" Ø OD TOP RAIL
2 3 8" Ø OD POSTS
@ 10'-0" O.C. MAX.
CONCRETE
FOUNDATION
TENSION WIRE
1 5 8" Ø OD BRACE
(SAME AS TOP RAIL)
FINISHED
GRADE
SCALE: 1/8" = 1'-0" 0 16'8'4'
NORTH ELEVATION1
A-201
A-201
A-201
EXT. ELEVATION GENERAL NOTES
A. DO NOT SCALE DRAWING. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS
AND CONDITIONS PRIOR TO THE START OF WORK.
1. EXISTING FINISHED GRADE.
2. REMOVE EXISTING WINDOWS, DOOR, AND/OR INFILL AT EXISTING MASONRY OPENING. INFILL
EXISTING OPENING WITH NEW CMU TO MATCH EXISTING THICKNESS, COURSING, AND BOND
(TOOTH-IN). PARGE EXTERIOR FACE TO MATCH EXISTING AND PAINT. SEE DEMOLITION PLAN.
3. METAL FASCIA.
4. REMOVE EXISTING ROOF AND PORTION OF EXISTING CMU WALLS DOWN TO 5'-8" A.F.F. +/- TO
MATCH HEIGHT OF EXISTING CMU SCREEN WALL TO REMAIN. SEE DEMOLITION PLAN.
5. ALUMINUM DOWNSPOUT.
6. ALUMINUM GUTTER.
7. DISCONNECT AND REMOVE PORTION OF EXISTING METAL DOWNSPOUT. INSTALL NEW METAL
DOWNSPOUT TO MATCH EXISTING SIZE IN SAME LOCATION AND RECONNECT TO EXISTING
PVC DOWNSPOUT.
8. 8'-0" HIGH BLACK VINYL COATED CHAIN LINK FENCE. SEE DETAIL 9, THIS SHEET.
9. PAIR OF 8'-0" WIDE VEHICLE SWING GATES.
10. 3'-0" WIDE SWING GATE.
N
E
S
W
PROJECT NORTH
SCALE: 1/8" = 1'-0" 0 16'8'4'
EAST ELEVATION2 SCALE: 1/8" = 1'-0" 0 16'8'4'
NORTH ELEVATION3
0 8'4'2'SCALE: 1/4" = 1'-0"
SECTION5 0 8'4'2'SCALE: 1/4" = 1'-0"
SECTION6 1'0 1/2' 1-1/2'SCALE: 1 1/2" = 1'-0"
DETAIL7 1'0 1/2' 1-1/2'SCALE: 1 1/2" = 1'-0"
DETAIL8A
A-201
EXTERIOR
ELEVATIONS,
WALL SECTION
AND DETAILS
IJ
AH
KEY PLAN
ISSUED FOR BIDJ:\
PR
OJ
\81
3-
\08
-C
AD
D\
-A
RC
HI
TE
CT
UR
AL
\A
-2
_E
LE
VA
TI
ON
S.
DW
G/
La yo ut1 /7/
/20
9:
A
M/ Jo vic ev ic, Is me ta
PROJECT NO:
CHECKED BY:
ISSUED DATE:
SHEET NO:
DRAWN BY:
© BUCHART HORN, INC.
MA
RK
IS
SU
ED
D
AT
E
DE
SC
RI
PT
IO
N
RE
VI
SI
ON
S
SHEET TITLE:
81083-17
SP
RU
CE
S
TR
EE
T W
AR
HO
US
E
RE
NO
VA
TI
ON
1 S
OU
TH
3R
D
ST
RE
ET
RE
AD
IN
G, P A, FO
R
TH
E
CI
TY
O F
RE
AD
IN
G
07/08/24
SCALE: 1/8" = 1'-0" 0 16'8'4'
WEST ELEVATION4
EXTERIOR ELEVATION KEY NOTES
11. DOOR. SEE DOOR SCHEDULE.
12. METAL COPING.
13. REMOVE EXISTING ROOFING AND ROOF STRUCTURE. SEE DEMOLITION PLAN.
14. REMOVE EXISTING CMU WALL IN ITS ENTIRETY. SEE DEMOLITION PLAN.
15. REMOVE EXISTING CONCRETE SLAB. SEE DEMOLITION PLAN.
16. REMOVE EXISTING STEEL BEAM. SEE DEMOLITION PLAN.
17. PARGE EXISTING PREVIOUS CMU INFILL AND PAINT.
18. EXISTING PVC DOWNSPOUT TO REMAIN.
19. PAINT EXISTING EXTERIOR WALLS. (PT-1) COLOR TO BE SELECTED BY OWNER.
20. PAINT EXISTING EXTERIOR WALLS. (PT-2) COLOR TO BE SELECTED BY OWNER.
21. REMOVE UPPER PORTION OF WALLS. SEE DEMOLITION PLAN.
22. REMOVE PORTION OF EXISTING CMU WALL FOR NEW OVERHEAD DOOR. V.I.F.
A-201
0 8'4'2'SCALE: 1/4" = 1'-0"
CHAIN LINK FENCE DETAIL (TYP)
EXISTING ROLLING
OVERHEAD DOOR
STORAGE
APPROX.
LINE OF FIN.
GRADE
STORAGE
REC. CENTER
STORAGE
12K1 STEEL JOISTSEXISTING W18X BEAM
TO REMAIN
EXISTING W12X BEAM
TO REMAIN
CMU INFILL
(TOOTH-IN MATCH
EXISTING COURSING
AND BOND.
MEMBRANE ROOFING ON 12"
COVER BOARD ON 5.2" (R-30)
RIGID ROOF INSULATION ON
VAPOR BARRIER ON 1 12" METAL
ROOF DECK
STORAGE
REC. CENTER
STORAGE
EXISTING COPING TO REMAIN
EXISTING CONST. TO REMAIN
EXISTING CONCRETE
SLAB TO REMAIN
3'-0" W CHAIN LINK FENCE GATE
H.O. OF ROOF
BEYOND
EXISTING CMU WALL
E A-301
F A-301
REMOVE UPPER PORTION
OF EXISTING CMU WALL
3'-0" W CHAIN LINK FENCE GATE
FULL HEIGHT CHAIN LINK FENCE TO
UNDERSIDE OF ROOF JOIST
MEMBRANE ROOFING ON 12"
COVER BOARD ON 5.2" RIGID
ROOF INSULATION (R-30) ON
VAPOR BARRIER
GUTTER
EX. CMU WALL
TREATED
WOOD BLOCKING
1 12" MTL ROOF ON
SLOPED METAL
ROOF FRAMING
4" CONT. STEEL
BENT PLATE
PROVIDE SPRAY
FOAM INSULATION
3'-10"STORAGE
-1'-0"
A A-301
B A-301
C A-301
9'-0" 15'-1 1/2"
TOOTH-IN NEW CMU WALL
TO MATCH EXISTING
COURSING AND BOND.
TOILET
STORAGE
FULL HEIGHT CHAIN LINK FENCE TO
UNDERSIDE OF ROOF JOIST
8'- 0"
NEW OVERHEAD
COIL DOOR
MEMBRANE ROOFING ON 12"
COVER BOARD ON 5.2" RIGID
ROOF INSULATION (R-30)
ON VAPOR BARRIER
7"x 7"x 12" BEARING PLATE WITH (2) 12" DIA x 6" LG
HEADED STUDS SET IN
16"W x 16"D GROUT BED
CONT. STEEL BENT PLATE
WOOD BLOCKING
METAL FASCIA W/ DRIP EDGE
1 12" 22 GA
GALVANIZED
TYPE B METAL
ROOF DECK
12K1 STEEL JOIST
EXISTING CMU WALL
PROVIDE SPRAY
FOAM INSULATION
12K1 STEEL JOIST
EXISTING
W18X BEAM
EXISTING
CMU WALL
MEMBRANE ROOFING ON 12"
COVER BOARD 5.2" ON RIGID
ROOF INSULATION (R-30)
ON VAPOR BARRIER
1 12" 22 GA GALVANIZED
TYPE B METAL
ROOF DECK
12K1 STEEL JOIST
CHAIN LINK FENCE
MEMBRANE ROOFING ON 12"
COVER BOARD ON 5.2" RIGID
ROOF INSULATION (R-30)
ON VAPOR BARRIER
1 12" 22 GA GALVANIZED
TYPE B METAL ROOF DECK
12K1 STEEL JOIST
FACE OF
ADJACENT BUILDING
EXISTING CMU WALL
EXP. JT. SUPPORT
1" EXP. JT
EXP. JT. FILLER
7"x 7"x 12" BEARING PLATE WITH (2) 12" DIA x 6" LG
HEADED STUDS SET IN
16"W x 16"D GROUT BED
TWO-PIECE
COUNTER-FLASHING
MEMBRANE
FLASHING
4" CONT. STEEL BENT PLATE
MEMBRANE ROOFING ON 12"
COVER BOARD ON 5.2" RIGID
ROOF INSULATION (R-30)
ON VAPOR BARRIER
1 12" 22 GA GALVANIZED
TYPE B METAL ROOF DECK
12K1 STEEL JOIST
EXISTING WALL TO REMAIN
COUNTER FLASHING
4" CONT. STEEL
BENT PLATE
METAL FASCIA TRIM
WITH DRIP EDGE
2x CONT. TREATED
WOOD BLOCKING
METAL TRIM
L5 x 3-1/2 x 3/8 (LLV) ANCHORED TO
EX. CMU WALLS WITH 3/4" DIA. SLEEVE
ANCHORS @ 16" O.C. (TYP. EA. END WALL)
REMOVE UPPER PORTION
OF EXISTING CMU WALL
MEMBRANE ROOFING ON 12"
COVER BOARD ON 5.2" RIGID
ROOF INSULATION (R-30)
ON VAPOR BARRIER
1 12" 22 GA GALVANIZED
TYPE B METAL ROOF DECK
12K1 STEEL JOIST
EXISTING WALL
TO REMAIN
EXP. JT. SUPPORT
1" EXP. JT
EXP. JT. FILLER
TWO-PIECE
COUNTER-FLASHING
MEMBRANE
FLASHING
EXISTING TERRACOTTA
COPING TO REMAIN
EXISTING
CONSTRUCTION
TO REMAIN
SEALANT
L5 x 3-1/2 x 3/8 (LLV) ANCHORED TO
EX. CMU WALLS WITH 3/4" DIA. SLEEVE
ANCHORS @ 16" O.C. (TYP. EA. END WALL)
0 8'4'2'SCALE: 1/4" = 1'-0"
SECTION1
1'0 1/2' 1-1/2'SCALE: 1 1/2" = 1'-0"
DETAILA
0 8'4'2'SCALE: 1/4" = 1'-0"
SECTION2
1'0 1/2' 1-1/2'SCALE: 1 1/2" = 1'-0"
DETAILB 1'0 1/2' 1-1/2'SCALE: 1 1/2" = 1'-0"
DETAILC 1'0 1/2' 1-1/2'SCALE: 1 1/2" = 1'-0"
DETAILD
A-301
BUILDING
SECTIONS AND
DETAILS
IJ
AH
ISSUED FOR BIDJ:\
PR
OJ
\81
3-
\08
-C
AD
D\
-A
RC
HI
TE
CT
UR
AL
\A
-3
_S
EC
TI
ON
S.
DW
G/ La yo ut1
/7/
/20
9:
A M/
Jo vic ev ic, Is me ta
PROJECT NO:
CHECKED BY:
ISSUED DATE:
SHEET NO:
DRAWN BY:
© BUCHART HORN, INC.
MA
RK
IS
SU
ED
D
AT
E
DE
SC
RI
PT
IO
N
RE
VI
SI
ON
S
SHEET TITLE:
81083-17
SP
RU
CE
S
TR
EE
T W
AR
HO
US
E
RE
NO
VA
TI
ON
1 S
OU
TH
3R
D
ST
RE
ET
RE
AD
IN
G, P A, FO
R
TH
E
CI
TY
O F
RE
AD
IN
G
07/08/24
1'0 1/2' 1-1/2'SCALE: 1 1/2" = 1'-0"
DETAILE 1'0 1/2' 1-1/2'SCALE: 1 1/2" = 1'-0"
DETAILF
2"1/2
SCHEDULED FRAME,
GROUT SOLID
EXISTING
CMU WALL
SCHEDULED
DOOR
5- 3/4
SEALANT BOTH SIDES
5-3/4"
2"
SCHEDULED FRAME,
GROUT SOLID
EXISTING CMU WALL
SEALANT BOTH
SIDES
SCHEDULED DOOR
1/2"
H1 J1
SCALE: 1-1/2" = 1'-0"
FRAME DETAILS
H2
S1
1/2
2"Ø x8"L SMOOTH
DOWELS AT 24" O.C.
REINFORCED CONC SLAB (FIELD
VERIFY SLOPE OF APRON)
OVERHEAD
COILING DOOR1" X 1" X 1/4" CONT. S/STL.
ANGLE W/ ANCHORS
2" JOINT FILLER
EXIST. CONC. WALK
EXIST. CONC. SLAB
(REMOVE PORTION
AS REQUIRED
STONE TO MATCH
EXISTING
J2
SLOPED CONC.
APRON BELOW
8" MIN.
1" X 1" X 1/4" CONT. S/STL.
ANGLE BELOW
OVERHEAD COILING DOOR
OVERHEAD
COILING DOOR TRACK
EXISTING
CONSTRUCTION
PARGE TO
MATCH EXISTING
OVERHEAD
COILING DOOR TRACK
W8x24 W/ 3 8" BOTTOM PLATE
(WITHIN 12" LESS THEN CMU)
WELDED TO BOTTOM FLANGE
(GALV. AND PAINT EXPOSED)
EXISTING CONSTRUCTIONB
PARGE TO
MATCH EXISTING
FACE OF THE
WALL BEYOND CMU - TOOTH INTO EXISTING
AND GROUT SOLID
ROOM
NO ROOM NAME SUB
FLOOR
FLOOR
FINISH
WALL
BASE
NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING
FOOTNOTES
MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MAT FIN
A101 STORAGE ROOM
A102 TOILET ROOM
EX CONC. -- -- EX CMU, CMU PT
EX CONC -- --
PTEX PLAS
EX CMU, CMU EX CMU EX CMU EXP
EX PLAS EX PLAS EX PLAS
ROOM FINISH SCHEDULE
EX PLAS
ROOM FINISH SCHEDULE GENERAL NOTES
A. SEE DEMOLITION DRAWINGS FOR EXTENT OF DEMOLITION OF
EXISTING MATERIALS AND FINISHES.
B. UNLESS MATERIAL OR FINISH IS PRECEDED BY "EXISTING" (EX, EXIST),
ROOM FINISH SCHEDULE IS INDICATING NEW MATERIAL AND/OR
FINISH.
C. PATCH, REPAIR, AND CLEAN ALL EXISTING SURFACES SCHEDULED TO
RECEIVE NEW FINISHES PER MANUFACTURER'S RECOMMENDATIONS.
D. ALL FLOORING MATERIAL TRANSITIONS SHALL OCCUR UNDER THE
CENTERLINE OF DOOR.
E. DO NOT PAINT NEW EXPOSED STRUCTURE (STEEL JOISTS, METAL
DECK). PAINT EXISTING EXPOSED STEEL ROOF SUPPORT BEAMS.
DOOR AND ROOM FINISH SCHEDULE ABBREVIATIONS
ACT ACOUSTICAL TILE CEILING
CLG CEILING
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CPT CARPET / CARPET TILE
CT CERAMIC TILE
EPT EPOXY PAINT
EX, EXIST EXISTING
ETR EXISTING TO REMAIN
EXP EXPOSED
FLR FLOOR(ING)
FRP FIBER REINFORCED PLASTIC
GLZ GLAZING
GWB GYPSUM WALL BOARD
PT PT
PT PT
PT PT
PT
HM HOLLOW METAL
HR HOUR
LVT LUXURY VINLY TILE
MATL MATERIAL
MET, MTL METAL
RB RUBBER BASE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PT PAINT(ED)
SIM SIMILAR
STL STEEL
THICK THICKNESS
U.N.O. UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
DOOR SCHEDULE GENERAL NOTES
A. PATCH, REPAIR, SAND, & PAINT EXISTING WOOD DOORS, FRAMES,
AND TRIM / CASING.
B. NEW DOOR HARDWARE MUST BE EASILY OPERATED WITH ONE HAND
AND NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF
THE WRIST TO OPERATE.
C. PROVIDE MASTER KEYING PER OWNER'S DIRECTION.
D. NEW DOOR HARDWARE SET #1 TO INCLUDE:
- 3 BUTT HINGES
- 1 LOCKSET W/ ENTRANCE FUNCTION
- 1 CLOSER
- 1 ALUMINUM THRESHOLD
DOOR SCHEDULE
DOOR
NO ROOM NAME
DOOR FRAME DETAILS
GLZ HDW
FUNC.
HDW
SET SIGNAGE NOTES
TYPE MAT WIDTH HEIGHT THICK TYPE MAT HEAD JAMB SILL
A101 STORAGE ROOM
A101A
HM 3'-0" 6' - 8" 1-3/4" HM --
STL S1
F1 H1 J1
OHCD
F --
12B
EXIT
8'-0" 8'-0" 2" -- STL J2H2 -- --
SCALE: 1/4" = 1'-0"
DOOR TYPE
DOOR
WIDTH
DO
OR
H
EI
GH
T
2"
2" 2"
F
FLUSH
FIN. FLR.
2'-
MI
N
HARDWARE
LOCATION1'-
2"
4'- 0"
M
AX
SCALE: 1/4" = 1'-0"
FRAME TYPE
F1
SEE DOOR SCHED. FOR DETAILS
FIN. FLR.
SIGNAGE GENERAL NOTES :
A. SIGN TYPES ARE PROVIDED FOR GENERAL REFERENCE ONLY. ALL SIGNAGE SHALL
COMPLY WITH 2018 IBC AND ICC A117.1-2009 REQUIREMENTS.
B. PROVIDE SIGNAGE AT LOCATIONS AS REFERENCED ON THE DOOR SCHEDULE. REFER
TO FLOOR PLANS FOR ADDITIONAL SIGNAGE LOCATIONS THAT MIGHT OCCUR.
C. ALL SIGNAGE SHALL HAVE A NON-GLARE FINISH. CHARACTERS AND PICTOGRAMS
SHALL CONTRAST WITH BACKGROUND.
D. CHARACTERS SHALL BE UPPER CASE, SANS SERIF. ITALIC, OBLIQUE, SCRIPT OR
DECORATIVE FONTS ARE NOT ACCEPTABLE.
E. VISUAL CHARACTERS SHALL BE 5/8" MIN IN HEIGHT, AND SHALL COMPLY WITH ICC
A117.1-2009, TABLE 703.2.4. RAISED CHARACTERS SHALL BE 5/8" MIN AND 2" MAX.
F. SPACING BETWEEN SEPARATE LINES OF CHARACTERS SHALL BE 135 % MIN AND 175
% MAX OF THE CHARACTER HEIGHT.
G. STROKE THICKNESS SHALL BE 10% MIN AND 30% MAX OF THE HEIGHT OF UPPER
CASE "I" FOR VISUAL CHARACTERS, AND 15% MIN AND 30% MAX OF THE HEIGHT OF
UPPER CASE "I" FOR RAISED CHARACTERS.
H. RAISED CHARACTERS SHALL BE 1/32" MIN ABOVE SIGN SURFACE.
I. BRAILLE, AND RAISED CHARACTERS SHALL BE SEPARATED 3/8" MIN FROM RAISED
BORDERS, AND OTHER RAISED ELEMENTS.
J. BRAILLE DOTS SHALL BE ROUNDED OR DOMED.
K. PICTOGRAMS SHALL HAVE A FIELD 6" MIN IN HEIGHT. NO OTHER ELEMENTS ARE
ALLOWED WITHIN REQUIRED FIELD.
VISUAL & RAISED CHARACTERS,
BRAILLE, PICTOGRAM WHERE
OCCURS
EXIT
TYPE 12B
6" x 4"
NON-ACCESSIBLE
EXIT
SCALE: 1/4" = 1'-0"
SIGN AT DOOR
9"
MIN
" M
IN
" M
AX
CL
NOTE: DIMENSIONS ARE TO BASELINE
OF LOWEST AND HIGHEST TACTILE
CHARACTER OR BRAILLE
BRAILLE
TEXT
SCALE: 1/4" = 1'-0"
SIGN TYPE
OHCD
OVERHEAD COILING DOOR
A102 TOILET ROOM WD --EX -- --2'-4" 6'-8" 1-3/4" EX WD ---- -- --
STORAGE ROOM MANUAL OPERATION
A-601
DOOR AND
ROOM FINISH
SCHEDULES,
DOOR AND
FRAME TYPES
AND DETAILS
IJ
AH
ISSUED FOR BIDJ:\
PR
OJ
\81
3-
\08
-C
AD
D\
-A
RC
HI
TE
CT
UR
AL
\A
-6
_S
CH
ED
UL
ES
.D
W G/
La yo ut1 /7/
/20
2:
P
M/ Jo vic ev ic, Is me ta
PROJECT NO:
CHECKED BY:
ISSUED DATE:
SHEET NO:
DRAWN BY:
© BUCHART HORN, INC.
MA
RK
IS
SU
ED
D
AT
E
DE
SC
RI
PT
IO
N
RE
VI
SI
ON
S
SHEET TITLE:
81083-17
SP
RU
CE
S
TR
EE
T W
AR
HO
US
E
RE
NO
VA
TI
ON
1 S
OU
TH
3R
D
ST
RE
ET
RE
AD
IN
G, P A, FO
R
TH
E
CI
TY
O F
RE
AD
IN
EUH
EUH
RH
EF
10x10 REGISTER W/ PLASTER
FRAME IN CEILING, PRICE 635 &
10x10 DUCT UP TO FAN
T-1
EF
X X X X X X X X X X X X X X X X X X X X X X X
REC. CENTER
STORAGE
EX. CONCRETE
WALK
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X X
X
X
X X
X
XX
X
X
X
X X
X
X X
X X
X
X X
X X
X
X
X
X
X
EX. CONCRETE
WALK
XX
EX. CONCRETE
WALK
PROVIDE ROOF VENTILATORS WITH 14" HIGH ROOF CURB WITH BACKDRAFT DAMPER, 2X6 WOOD NAILER, UNIT MOUNTED DISCONNECT BY MANUFACTURER, INSTALL EXHAUST FANS LEVEL, CURBS TO BE SLOPED TO MATCH ROOF SLOPE. MANUAL MOTOR STARTERS BY E.C.
EXHAUST FAN SCHEDULE SCHEDULE
MARK
EF-1 2000
TYPE
POWER ROOF VENTILATOR
VOLTAGE WEIGHT
(LBS.)CFM SONES
8.5
MANUFACTURER
GREENHECK
MODEL
160-VG.30
SP
RPM
3/4
HP
EF-2 GREENHECK 060-VG120 120 204.25 1550 1/10
POWER ROOF VENTILATOR
PROVIDE 14" HIGH ROOF CURB AND 2X6 TREATED WOOD NAILER.
INSTALL ROOF HOODS LEVEL, CURBS TO BE SLOPED TO MATCH ROOF SLOPE.
DAMPER TO BE RUSKIN CD-50 WITH 120 VOLT BELIMO ACTUATOR, INTERLOCK W/ EF-1
ROOF HOOD SCHEDULE
MARK DAMPER TYPE MANUFACTURER MODEL
RH-1 20 x 20 CONTROL DAMPER GREENHECK FGI
THROAT SIZE
925IU-UH7504-NINDEECO
MODELMANUFACTURER
240-1-60
VOLTAGE
7.5
KW
EUH-1
MARK
ELECTRIC UNIT HEATER SCHEDULE
AMPS
CFM
PROVIDE WITH INTEGRALTHERMOSTAT AND DISCONNECT
EUH-2 925IU-UH7504-NINDEECO240-1-607.5 32 500
1. ENTIRE SYSTEM SHALL BE IN STRICT ACCORDANCE WITH NFPA 70.
CONTROL REQUIREMENTS
2. ALL WIRING SHALL BE IN STRICT ACCORDANCE WITH ALL DIVISION 26 SPECIFICATIONS.
3. PROVIDE ALL WIRING, RELAYS, TRANSFORMERS AND SWITCHES AS REQUIRED FOR A COMPLETE INSTALLATION.
4. UNIT HEATER TO BE EQUIPPED WITH FACTORY SUPPLIED INTEGRAL THERMOSTATS, SET FOR 65 DEGREES.
5. THERMOSTAT, T-1 FOR EXHAUST FAN SHALL BE 120 VOLT LINE VOLTAGE WHITE RODGERS MODEL 151
COOLING ONLY THERMOSTAT. SET TO ENERGIZE EXHAUST FAN AT 75 DEGREES.
INTERLOCK WITH CORRESPONDING INTAKE AIR DAMPER, DAMPER ACTUATOR TO BE BELIMO OR EQUAL.
6. EF-2 TO HAVE WALL MOUNTED MANUAL MOTOR STARTER W/ PILOT LIGHT.
1. ENTIRE SYSTEM SHALL BE IN STRICT ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE.
GENERAL REQUIREMENTS
2. CONTRACTOR SHALL PROVIDE COMMISSIONING, STARTUP AND BALANCING OF ALL EQUIPMENT.
3. CONTRACTOR SHALL SECURE AND PAY FOR ALL REQUIRED PERMITS.
4. COORDINATE WORK REQUIREMENTS WITH ALL OTHER TRADES.
5. DUCTWORK SHALL BE 20 GAGE GALVANIZED STEEL.
6. PROVIDE MISCELLANEOUS 2 BY 2 BY 1/4 STEEL ANGLES TO FRAME ROOF OPENINGS.
7. SUBMIT SHOP DRAWINGS FOR ALL EQUIPMENT AND CONTROLS.
8. SUBMIT OPERATING AND MAINTENANCE MANUALS AT COMPLETION OF PROJECT.
ALUMINUM HOUSING
1/2" ALUMINUM
BIRDSCREEN
TREATED WOOD
NAILERSROOF
BACKDRAFT
DAMPER
COUNTER FLASHIING
ROOF CURB MINIMUM
14" ABOVE FINISHED ROOF
ALUMINUM HOUSING
1/2" ALUMINUM
BIRDSCREEN
COUNTER FLASHIING
ROOF CURB MINIMUM
14" ABOVE FINISHED ROOF
TREATED WOOD
NAILERSROOF
CONTROL
DAMPER
M-101
FLOOR PLAN -
MECHANICAL
RCM
RCM
SCALE: 1/8" = 1'-0"1 FLOOR PLAN - MECHANICAL
NOT TO SCALE2 EXHAUST FAN DETAIL
NOT TO SCALE3 ROOF HOOD DETAIL
ISSUED FOR BIDJ:\
PR
OJ
\81
3-
\08
-C
AD
D\
-M
EC
HA
NI
CA
L\M
1.D
W G/
M-
1/7 /10
/20
2:
P M/
Jo vic ev ic, Is me ta
PROJECT NO:
CHECKED BY:
ISSUED DATE:
SHEET NO:
DRAWN BY:
© BUCHART HORN, INC.
MA
RK
IS
SU
ED
D
AT
E
DE
SC
RI
PT
IO
N
RE
VI
SI
ON
S
SHEET TITLE:
81083-17
SP
RU
CE
S
TR
EE
T W
AR
HO
US
E
RE
NO
VA
TI
ON
1 S
OU
TH
3R
D
ST
RE
ET
RE
AD
IN
G, P A, FO
R
TH
E
CI
TY
O F
RE
AD
IN
PANELBOARD
EQUIPMENT CABINET
C
JUNCTION BOX
H
CONTACTOR
RELAY
METER
ENCLOSED CIRCUIT BREAKER
MOTOR OR EQUIPMENT
ELECTRIC SOLENOID VALVE - BY OTHERS (H-HOT
WATER, C-COLD WATER, G-GAS)
MAST HEAD
TRANSFORMER - 120V AND GREATER
TRANSFORMER - LOW VOLTAGE
SAFETY SWITCH - NON-FUSED, 3-POLE, 30A,
600V UNO
SAFETY SWITCH - FUSED, 3-POLE,
30A, 600V UNO
COMBINATION STARTER / DISCONNECT - 3 PHASE
CABLE TRAY - WALL HUNG
CABLE TRAY - CENTER HUNG
CONDUIT SLEEVE - QUANTITY AND SIZE AS
REQUIRED
EMPTY CONDUIT- SEALED & CAPPED
CIRCUIT
HOMERUN TO PANELBOARD; PROVIDE 3 #12, #12 GRD,
3/4"C UNLESS NOTED OTHERWISE ON DRAWING, ON
PANEL SCHEDULES, OR ONE LINE DIAGRAMS
CIRCUIT - EQUIPMENT ON SAME
CIRCUIT BUT SEPARATELY
CONTROLLED
VOICE/DATA OUTLET - TWO ACTIVE PORTS UNO
TELEPHONE OUTLET - LETTER 'W' ADJACENT TO
SYMBOL INDICATES OUTLET FOR WALL HUNG PHONE
LETTER "C" ADJACENT TO SYMBOL INDICATES
OUTLET ABOVE COUNTER
SURFACE MOUNTED RACEWAY MOUNTED -
TELECOM OUTLETS AS INDICATED
NUMBER ADJACENT TO SYMBOL INDICATES
NUMBER OF ACTIVE PORTS: 2, 4, 6 OR 8
TELECOM/NETWORK BACKBOARD
TELECOM/NETWORK EQUIPMENT RACKTEC
EQUIP
RACK
TELEPHONE (VOICE) OUTLET - TWO ACTIVE
PORTS UNO
DATA OUTLET - TWO ACTIVE PORTS UNO
CLG FLOOR WALL
NUMBER ADJACENT TO SYMBOL INDICATES
MOUNTING HEIGHT A.F.F.
LETTER "F" ADJACENT TO SYMBOL INDICATES
FIBER OPTIC OUTLET
MULTIPLEXER
MAGNETIC DOOR CONTACTS
(NUMBER INDICATES ZONE IF REQUIRED)
PUSHBUTTON
KEYPAD
CARD/PROXIMITY READER
BIOMETRIC READER
ELECTRIC LOCK - BY OTHERS
ELECTRIC STRIKE - BY OTHERS
INTERCOM STATION - WALL MTD
INTERCOM STATION - MASTER
MONITOR
CAMERA
NUMBER ADJACENT TO SYMBOL INDICATES
MOUNTING HEIGHT A.F.F.
REMOTE TEST STATION - WALL MTD
L
LETTER L INDICATES TEST LIGHT
REMOTE TEST STATION - CEILING MTD
FIRE SUPPRESSION FLOW SWITCH - BY OTHERS
FIRE SUPPRESSION TAMPER SWITCH - BY OTHERS
FIRE ALARM CONTROL PANEL
F
DOOR HOLDER
(F-FLOOR, C-CEILING, W-WALL)
CONTROL MODULE - ZONE
CONTROL MODULE - ADDRESSABLEA
SMOKE DETECTOR
CLG WALL
D
LETTER ADJACENT TO SYMBOL INDICATES PREFERRED
DETECTOR TYPE:
D -DOOR
P -PREACTION
R -ELEVATOR RECALL
RE - SHAFT & EXHAUST ELEVATOR RECALL
RS - ELEVATOR RECALL & SPRINKLER ACTIVATION
HEAT DETECTOR
CARBON MONOXIDE DETECTOR
DUCT DETECTOR - SMOKE
(NUMBER INDICATES ZONE, IF REQUIRED)
DUCT DETECTOR - HEAT
(NUMBER INDICATES ZONE, IF REQUIRED)
AUDIBLE WITH VISUAL UNIT
AUDIBLE ONLY UNIT
VISUAL ONLY UNIT
CLG WALL
MANUAL PULL STATION
(NUMBER INDICATES ZONE IF REQUIRED)2
MANUAL PULL STATION - KEY OPERATEDK
MANUAL PULL STATION WITH CLEAR PROTECTIVE
COVER
C
AUDIBLE WITH VISUAL UNIT
AUDIBLE ONLY UNIT
VISUAL ONLY UNIT
CLG WALL
UNDERGROUND EMERGENCY/STANDBY GENERATOR
SERVICE
UNDERGROUND ELECTRIC SERVICE (PRIMARY)
UNDERGROUND ELECTRIC SERVICE (SECONDARY)
UNDERGROUND CATV & TELEPHONE SERVICE
UNDERGROUND SITE LIGHTING CONDUIT
UNDERGROUND EMPTY CONDUIT
UNDERGROUND BRANCH CIRCUIT CONDUIT
TELECOMMUNICATION CONDUIT
UTILITY POLE
MANHOLE/VAULT
POLE MOUNTED H.I.D. LIGHT FIXTURE - SINGLE
HEAD WITH ARM BRACKET
POLE MOUNTED H.I.D. LIGHT FIXTURE - DUAL
HEAD WITH ARM BRACKET
POLE MOUNTED H.I.D. LIGHT FIXTURE - SINGLE
HEAD POST MOUNT
BUILDING UPLIGHT FIXTURE
BOLLARD LIGHT FIXTURE
UNDERGROUND ELECTRICAL ENCLOSURE
PAD MOUNT TRANSFORMER
SURGE PROTECTION DEVICE
SURFACE FLUSH
CLG FLOOR WALL
BLANK OUTLET
JUNCTION BOX OR BLANK OUT - ABOVE FLOOR,
IN CAST BOX ON RIGID CONDUIT
JUNCTION BOX OR BLANK OUT - ABOVE COUNTER
VOICE/DATA POLE - TELECOM OUTLETS AS INDICATED
POWER/TELECOM POLE - TELECOM OUTLETS AS
INDICATED
FURNITURE PEDESTAL - TELECOM OULTES AS
INDICATED
TELECOM/NETWORK EQUIPMENT CABINET
SURFACE FLUSH
NUMBER ADJACENT TO SYMBOL INDICATES ZONE, IF
REQUIRED
SURFACE FLUSH
THE NUMBER ADJACENT TO THE SYMBOL INDICATES
PREFERRED CANDELA VALUE. VISUAL SYMBOL WITHOUT
IDENTIFICATION SHALL BE AS FOLLOWS:
CORRIDORS / HALLWAYS - 30 CANDELA
ROOMS <= 2,000 SQFT - 75 CANDELA
ROOMS > 2,000 SQFT - 110 CANDELA
CLG WALL
MOTION DETECTOR
(NUMBER INDICATES ZONE IF REQUIRED)
SPEAKER
CLG WALL
SECURITY EQUIPMENT CABINET
SURFACE FLUSH
UGE
UPE
USE
UTC
SL
EC
BC
TC
CEILING SURFACE
MOUNTED
CEILING RECESSED
CEILING PENDANT
CEILING SURFACE MOUNTED
CEILING RECESSED
CEILING PENDANT
CEILING SURFACE MOUNTED
CEILING RECESSED
CEILING PENDANT
CEILING SURFACE
MOUNTED
CEILING RECESSED
CEILING PENDANT
CEILING SURFACE MOUNTED
CEILING RECESSED
CEILING PENDANT
WALL MOUNTED - DIRECTIONAL ARROW
AS REQUIRED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
WALL MOUNTED
EMERGENCY LIGHTING UNIT - BATTERY TYPE
WITH NUMBER OF HEADS AS INDICATED
SMN
FEED END
HORIZONTAL/VERTICAL RUN
TRACK MOUNTED LIGHT FIXTURES - WITH
FLOOD AND/OR SPOT TYPES
FLOOD
M - MEDIUM
N - NARROW
W - WIDE SPOT
S - NORMAL
EMERGENCY LIGHTING UNIT - REMOTE HEAD
WITH NUMBER OF HEADS AS INDICATED
GENERAL
FIXTURE WITH "NIGHT LIGHT" CONNECTED TO
NORMAL OR NORMAL/EMERGENCY CIRCUIT
LIGHT FIXTURE CONNECTED TO
NORMAL/EMERGENCY, EMERGENCY ONLY
OR BATTERY INVERTER CIRCUIT
LIGHT FIXTURE WITH EMERGENCY
BATTERY BALLAST
LIGHT FIXTURE WITH EMERGENCY
ONLY SOCKET
CLG WALL
ILLUMINATED FACE
SINGLE FACE, CEILING MOUNTED -
DIRECTIONAL ARROW AS REQUIRED
DUAL FACE, CEILING MOUNTED - DIRECTIONAL
ARROWS AS REQUIRED
C
POWER PACT
PHOTO SENSOR - WALL MTD
(MOUNTED ON NORTH FACE OF BUILDING)
PHOTO SENSOR - CEILING MTD
SINGLE
CLG FLOOR WALL
DUPLEX
GFCI
SPD (ISOLATED GROUND)
SPD DOUBLE DUPLEX
TAMPER RESISTANT
SPLIT WIRED
THREE PHASE, 480V RATED WITH AMPERAGE
AS INDICATED
30A 30A30A
DOUBLE DUPLEX
GFCI DOUBLE DUPLEX
SINGLE PHASE, 480V RATED WITH
AMPERAGE AS INDICATED
72"
NUMBER ADJACENT TO SYMBOL INDICATES
MOUNTING HEIGHT A.F.F.
C LETTER "C" ADJACENT TO SYMBOL INDICATES
RECEPTACLE ABOVE COUNTER
40A40A40A
ABOVE FLOOR, IN CAST BOX ON RIGID CONDUIT
- RECEPTACLE TYPE AS SHOWN
SWITCH - PIR WITH PUSHBUTTON
SINGLE POLE
POWER/TELECOM POLE - WITH WIRING DEVICES AS
INDICATED
FURNITURE PEDESTAL - WITH WIRING DEVICES AS
INDICATED
SURFACE MOUNTED RACEWAY MOUNTED - WIRING
DEVICES AS INDICATED
FIRE RATED POKE-THROUGH - WIRING DEVICES
AND TELECOM OUTLETS AS INDICATED
FLUSH FLOOR BOX - WIRING DEVICES AND
TELECOM OUTLETS AS INDICATED
SURFACE RACEWAY WITH WIRING DEVICES AS
INDICATED
HORIZONTAL RUN
VERTICAL DROP
POWER POLE - WITH WIRING DEVICES AS INDICATED
72" 72"
M
SURFACE RACEWAY
MANUAL MOTOR STARTER (HP RATED)
THE LETTERS ADJACENT TO THE SYMBOL INDICATE
STARTER TYPE.
M - TOGGLE
MK - KEY OPERATED
MB - PUSHBUTTON
MT - TOGGLE WITH THERMAL OVERLOADS
THE LETTERS/NUMBERS ADJACENT TO THE SYMBOL
INDICATE SWITCH TYPE. SWITCHES ARE SINGLE POLE
UNLESS IDENTIFIED OTHERWISE.
3 - THREE-WAY
4 - FOUR-WAY
B - TOUCHBOLT
CK - CARD KEY
D - DIMMER - INCANDESCENT
DF - DIMMER - FLUORESCENT
DL - DIMMER - LOW VOLTAGE
ET - ELECTRONIC TAP
K - KEY OPERATED
MC - MAINTAINED CONTACT
P - PILOT LIGHT
R - LOCAL REMOTE CONTROL
WP - WEATHERPROOF
X - EXPLOSION PROOF
LV - LOW VOLTAGE
RADIAL - AUTO ON/OFF
CLG WALL
DIRECTIONAL - AUTO ON/OFF
DT
THE LETTERS ADJACENT TO THE SYMBOL INDICATES
SENSOR TYPE. WHERE SENSOR SYMBOL IS SHOWN
WITHOUT IDENTIFICATION, PROVIDE PIR FOR WALL
TYPES AND DT FOR CEILING TYPES.
DT - DUAL TECHNOLOGY (COMBINATION PIR &
US)
ER - EXTENDED RANGE
HB - HIGHBAY
HH- HIGH HUMIDITY / LOW TEMPERATURE
HW- HALLWAY
PIR- PASSIVE INFRARED
R - RELAY
US - ULTRASONIC OR MICROPHONIC
WP- WEATHERPROOF
WV- WIDE VIEW
THE LETTERS/NUMBERS ADJACENT TO THE SYMBOL
INDICATE SWITCH SENSOR TYPE. SWITCH SENSORS
ARE PIR TYPE UNLESS IDENTIFIED OTHERWISE.
OC1 - DUAL TECHNOLOGY WITH 1 PUSHBUTTON
OC2 - DUAL TECHNOLOGY WITH 2 PUSHBUTTONS
FOR DUAL CONTROL
THE LETTER ADJACENT TO THE SYMBOL INDICATES TYPE.
PUSHBUTTONS ARE STANDARD UNLESS IDENTIFIED
OTHERWISE.
E - EMERGENCY
K - EMERGENCY, KEY OPERATED
P - PANIC/ENTRANCE
STANDARD
E
SURFACE RACEWAY
C
W
F
FACP FACP
42"
TECTEC
SSCPSSCP
RISER, OR ONE LINE NOTE NUMBER
(E.G., SEE RISER NOTE NO. E1) E1
SHEET KEYNOTE
(NEW CONSTRUCTION)
DEMOLITION KEYNOTE
REVISION SEQUENCE NUMBER
AHU-2EQUIPMENT TAG
SECTION/
ELEVATION
REFERENCE
INTERIOR
ELEVATION
REFERENCE
DETAIL /
CALLOUT
REFERENCE
VIEW REF
SHEET REF
VIEW REF
SHEET REF
VIEW REF
SHEET REF
BOX TAG/NOTE REFERENCE
BOXED TAG(S)/NOTE(S) BELOW THE ROOM NAME/NUMBER OR PLACED IN THE
SPACE INDICATE THAT THE INFORMATION IN THE BOX APPLIES TO ALL
FIXTURES AND/OR RECEPTACLES IN THE ROOM/SPACE UNLESS NOTED
OTHERWISE.
PANEL NAME
LIGHT FIXTURE DESIGNATOR (ONLY
ON LIGHTING PLANS)
POWER CIRCUIT FOR RECEPTACLES
OR LIGHTING FIXTURES
EMERGENCY CIRCUIT (IF REQUIRED)KEY NOTE
(TYP.)
RA 60
LSA 10
P1 6
ROOM NAMEROOM TAG
(ROOM NO NOT ALWAYS SHOWN) RM #
T
T
LT
A-XXX
AXXX
ELECTRICAL, COMMUNICATION, PROCESS CONTROL, AND ELECTRONIC SAFETY AND SECURITY SYMBOL LEGEND LIGHTING POWER DISTRIBUTION WIRING DEVICES WIRING DEVICES (CONTINUED) TELECOMMUNICATION/NETWORK SECURITY/ACCESS/SURVEILLANCE
GENERAL
SITE
FIRE ALARM
INTERCOM/SOUND/PROGRAM
WIRING DIAGRAMS
WIRES NOT CONNECTED
CONNECTING
WIRES
SYMBOLS LEGEND NOTES:
A. NOT ALL SYMBOLS INDICATED MAY APPEAR ON THESE
CONTRACT DRAWINGS.
B. DASHED SYMBOLS REPRESENT EXISTING EQUIPMENT OR
EQUIPMENT NOT IN CONTRACT.
GROUND BAR
INTERCOM HANDSET
CALL-IN SWITCH
VOLUME CONTROL
MICROPHONE OUTLET
FLOOR WALL
PROJECTION OUTLET
TELEVISION OUTLET
NUMBER ADJACENT TO SYMBOL INDICATES
MOUNTING HEIGHT A.F.F.
LETTER "C" ADJACENT TO SYMBOL INDICATES
OUTLET ABOVE COUNTER
CLOCK - ANALOG
WALL
CLG
RECESSED
CLG
SURFACE
CLG
RECESSED
CLG
SURFACE
TELEPHONE HANDSET - DESKTOP
THE LETTER ADJACENT TO THE SYMBOL INDICATES
SYSTEM
L - LOCAL SYSTEM
I - INTERCOM SYSTEM
P - PAGING/PROGRAM
L
SPEAK/SIGN COMBINATION UNIT FOR INTERCOM,
PAGING, AND MASS NOTIFICATION UNO
THE LETTER ADJACENT TO THE SYMBOL INDICATES
TYPE. WHERE CLOCK SYMBOL IS SHOWN WITHOUT
IDENTIFICATION, PROVIDE ANALOG WITH 12" FACE
SIZE.
T - DIGITAL WITH INTERNAL TIMER
Z - DIGITAL
D - DOUBLE FACE
15 - NUMBER INDICATES FACE SIZE
SPEAKER - HORN
E-001
ELECTRICAL
SYMBOL LEGEND
TEB
CLM
ISSUED FOR BIDJ:\
PR
OJ
\81
3-
\08
-C
AD
D\
-E
LE
CT
RI
CA
L\E
-0
.D W
G/ La yo ut1
/7/
/20
2:
P M/
Jo vic ev ic, Is me ta
PROJECT NO:
CHECKED BY:
ISSUED DATE:
SHEET NO:
DRAWN BY:
© BUCHART HORN, INC.
MA
RK
IS
SU
ED
D
AT
E
DE
SC
RI
PT
IO
N
RE
VI
SI
ON
S
SHEET TITLE:
81083-17
SP
RU
CE
S
TR
EE
T W
AR
HO
US
E
RE
NO
VA
TI
ON
1 S
OU
TH
3R
D
ST
RE
ET
RE
AD
IN
G, P A, FO
R
TH
E
CI
TY
O F
RE
AD
IN
G
07/08/24
/1
0/
E-002
ELECTRICAL
ABBREVIATIONS
TEB
CLM
ISSUED FOR BIDJ:\
PR
OJ
\81
3-
\08
-C
AD
D\
-E
LE
CT
RI
CA
L\E
-0
.D W
G/ La yo ut1
/7/
/20
2:
P M/
Jo vic ev ic, Is me ta
PROJECT NO:
CHECKED BY:
ISSUED DATE:
SHEET NO:
DRAWN BY:
© BUCHART HORN, INC.
MA
RK
IS
SU
ED
D
AT
E
DE
SC
RI
PT
IO
N
RE
VI
SI
ON
S
SHEET TITLE:
81083-17
SP
RU
CE
S
TR
EE
T W
AR
HO
US
E
RE
NO
VA
TI
ON
1 S
OU
TH
3R
D
ST
RE
ET
RE
AD
IN
G, P A, FO
R
TH
E
CI
TY
O F
RE
AD
IN
G
07/08/24
E L E C T R I C A L A B B R E V I A T I O N S, M O U N T I N G H E I G H T S, A N D G E N E R A L LA Y O U T N O T E S
A. COORDINATE INSTALLATION OF NEW ITEMS AND EQUIPMENT WITH THE OWNER'S REPRESENTATIVE, MAINTENANCE STAFF, AND THE WORK OF OTHER CONTRACTORS. THE CONTRACTOR SHALL INCUR
ALL COSTS ASSOCIATED WITH THE RELOCATION OF EQUIPMENT CONFLICTING WITH NEW WORK BY
OTHER DISCIPLINES THAT HAS NOT BEEN COORDINATED.
B. FIELD VERIFY ALL DIMENSIONS. DRAWINGS ARE ILLUSTRATIVE AND MAY NOT REFLECT EXACT
CONDITIONS OR DIMENSIONS.
C. DO NOT SCALE THE DRAWINGS. DRAWINGS ARE DIAGRAMMATIC AND SHOW THE GENERAL
ARRANGEMENT OF EQUIPMENT AND SYSTEMS. THEY ARE NOT INTENDED TO SHOW EVERY OFFSET, FITTING AND COMPONENT. DO NOT USE THE PLANS FOR EXACT LOCATION OF EQUIPMENT, FIXTURES OR ARCHITECTURAL ITEMS SUCH AS WALLS, WINDOWS, SOFFITS, AND PILASTERS.
SPECIFIC LOCATIONS, MOUNTING HEIGHTS AND OVERALL DIMENSIONS OF DEVICES AND FIXTURES
ARE TO BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS AND DETAILS WHEN AVAILABLE.
D. DRAWINGS SPECIFIC TO THIS TRADE DO NOT LIMIT THE RESPONSIBILITY OR WORK REQUIRED BY
THE CONTRACT DOCUMENTS. REFER TO DRAWINGS AND SPECIFICATIONS OF OTHER TRADES FOR
COMPLETE INFORMATION PRIOR TO BID.
E. WHERE CONFLICTS EXIST AMONG DRAWINGS, SPECIFICATIONS AND EQUIPMENT SCHEDULES, THE MOST STRINGENT SHALL APPLY. NOTIFY THE ENGINEER OF ALL CONFLICTS FOR RESOLUTION OR
INTERPRETATION.
F. NOTIFY THE OWNER IN WRITING AND FIELD VERIFY CONDITIONS BEFORE PERFORMING ANY
SAWCUTTING, TRENCHING, CORING OR ANY OTHER STRUCTURAL MODIFICATIONS. INSURE THAT NO
ADVERSE EFFECT TO THE BUILDING'S STRUCTURAL INTEGRITY WILL OCCUR.
G. BRANCH CIRCUIT SIZING FROM DISCONNECT, STARTER OR VFD, OR CONTROL PANEL TO
MOTOR/EQUIPMENT SHALL MATCH WHAT IS SHOWN FROM MCC/PANELBOARD TO DISCONNECT,
STARTER OR VFD, OR CONTROL PANEL UNO. MOTOR BRANCH CIRCUITS FED FROM VFD SHALL BE
VFD CABLE IN APPROPRIATELY SIZED CONDUIT.
H. ALL EQUIPMENT INSTALLED WITHIN AREAS THAT ARE LISTED AS CLASSIFIED AREAS SHALL BE UL
LISTED AND LABELED FOR INSTALLATION IN THAT AREA. ALL CONDUIT TRANSITIONING FROM
CLASSIFIED AREAS TO UNCLASSIFIED AREAS SHALL HAVE PROPER SEAL OFF FITTINGS.
I. ALL WORK SHOWN IN BOLD IS NEW WORK OR MODIFICATION OF EXISTING INSTALLATIONS TO BE
COMPLETED BE THE CONTRACTOR UNDER THIS PROJECT. SEE PROJECT SPECIFICATIONS,
SEQUENCE / PHASING OF WORK, AND DIVISION 1 FOR ADDITIONAL REQUIREMENTS FOR THIS
PROJECT. CONTRACTOR SHALL READ AND UNDERSTAND THE REQUIREMENTS BEFORE SUBMITTING
BID OR COMPLETING CONTRACTOR WORK.
WALL HEATERWH
VACUUM RETURN PUMPVRP
VARIABLE AIR VOLUME BOXVAV
UNIT VENTILATORUV
UNIT HEATERUH
THERMOSTATIC MIXING VALVETMV
TRASH COMPACTORTC
SPLIT SYSTEM FANSS
SUMP PUMPSP
SUPPLY FANSF
SMOKE DAMPERSD
SELF CONTAINED UNITSCU
ROOF TOP UNITRTU
REHEAT COILRHC
REFRIGERATORREF
RETURN AIR FANRAF
PREHEAT COILPHC
PUMPP
OVERHEAD DOOROHD
MOTOR OPERATED DAMPERMOD
MAKE UP AIR UNITMAU
AUTOMATIC FAUCET SENSORL
JOCKEY PUMPJP
INSTANTANEOUS WATER HTRIWH
INFRARED HEATERIRH
INTAKE FANIF
MAXIMUM FUSE AMPSMFA
MECHANICALMECH
MOTOR CONTROL CENTERMCC
MINIMUM CIRCUIT AMPSMCA
MECHANICAL CONTRACTORMC
MAIN CIRCUIT BREAKERMCB
MAXIMUMMAX
MASTER ANTENNA TV SYSTEMMATV
MATERIALMAT
MILLIAMPEREmA
LOW VOLTAGELV
LIGHTINGLTG
LEFTLT
LOCKED ROTOR AMPSLRA
LUMENS PER WATTLPW
LIGHT POLELP
LINEARLIN
LINEAR FEET (FOOT)LF
LIGHT EMITTING DIODELED
POUND(S)LB or LBS
LIGHTNING ARRESTERLA
LONG OR LOCKABLEL
KILOWATT HOUR METERKWHM
KILOWATT HOURKWH
KILOWATTKW
KILOVOLT AMPERE REACTIVEKVAR
KILOVOLT AMPERE PER HOURKVAH
KILOVOLT AMPEREKVA
KILOVOLTKV
KNOCKOUTKO
KILOHERTZKHZ
KILO OR KELVIN OR THOUSANDK
JUNCTION BOXJB
INFRAREDIR
INVERTERINV
INTERCOMMUNICATIONINTERCOM
INCHESIN
IDENTIFICATION NUMBERID NO
INSIDE DIAMETERID
INTERNATIONAL BUILDING CODEIBC
INPUT/OUTPUTI/O
HERTZ (FREQUENCY)Hz
HIGH VOLTAGEHV
HEIGHTHT
HOURHR
HORSEPOWERHP
HAND-OFF-AUTOMATICHOA
HIGH DENSITY POLYETHYLENEHDPE
HEAVY DUTYHD
HAZARDHAZ
HIGHH
GROUNDGRD
YEARYR
WYEY
TRANSFORMERXFMR
TRANSFERXFER
WATERTIGHT OR WEIGHTWT
WEATHERPROOFWP
WET LOCATIONWL
WITHOUTW/O
WITHW/
WATT OR WIREW
VOLTAGE REGULATORVR
VOLTAGEVOLTS
VARIABLE FREQUENCY DRIVEVFD
VARIABLE FREQUENCYVF
VOLTAGE DROPVD
VOLT AMPERE REACTIVEVAR
VARIESVAR
VOLT-AMMETERVAM
VOLT AMPEREVA
VOLTV
UNSHIELDED TWISTED PAIRUTP
UNINTERRUPTIBLE POWER SUPPLYUPS
UNLESS NOTED OTHERWISEUNO
UNDERWRITERS LABORATORIESUL
TYPICALTYP
TELEVISIONTV
TWIST LOCKTL
TO FLOOR BELOWTFB
TO FLOOR ABOVETFA
TEMPERATURETEMP
TELEPHONETEL
SWITCHGEARSWGR
SWITCHBOARDSWBD
STANDARDSTD
SHUNT TRIP OR SINGLE THROWST
SQUARE YARDSQ YD
SQUARE INCHSQ IN
SQUARE FOOT (FEET)SQ FT
SQUARESQ
SINGLE POLE, SINGLE THROWSPST
SPECIFICATIONSPEC
SINGLE POLE, DOUBLE THROWSPDT
SURGE PROTECTION DEVICESPD
SECOND OR SECONDARYSEC
SEMICONDUCTOR CONTROLLED
RECTIFIER
SCR
SCHEDULESCH or SCHED
SOUTHS
RIGHTRT
REVOLUTIONS PER MINUTERPM
RIGHT OF WAYROW
ROOMRM
REQUEST FOR INFORMATIONRFI
RADIO FREQUENCYRF
REVISIONREV
RECEPTACLERECPT
REFLECTED CEILING PLANRCP
RADIUSR
QUANTITYQTY
QUAL ASSURANCE/QUAL CONTROLQA/QC
POWERPWR
PHOTOVOLTAICPV
POTENTIAL TRANSFORMERPT
PRIMARYPRI
PRELIMINARYPRELIM
POINT OF COMMON COUPLINGPOCC
PURCHASE ORDERPO
PANELPNL
PART NUMBERPN
PROPERTY LINEPL
PHASEPH
PROVISION FOR FUTURE BREAKERPFFB
POWER FACTORPF
PHOTOELECTRIC CELLPEC
PROFESSIONAL ENGINEERPE
POWER CONDITIONING UNITPCU
PLUMBING CONTRACTORPC
PULL BOX OR PUSHBUTTONPB
PUBLIC ADDRESSPA
PENDANT OR POLEP
OVERLOADOL
OUTSIDE DIAMETEROD
ON CENTEROC
NOT TO SCALENTS
NOMINALNOM
NORMALLY OPENNO or N/O
NIGHT LIGHTNL
NOT IN CONTRACTNIC
NONFUSEDNF
NATIONAL FIRE PROTECTION ASSOCNFPA
NEUTRALNEUT
NEGATIVENEG
NATIONAL ELECTRICAL CODENEC
NORMAL/EMERGENCYNE
NORMALLY CLOSEDNC or N/C
NOT APPLICABLENA or N/A
NORTH OR NEUTRALN
MEGAWATT HOURMWH
MEGAWATTMW
MILLIWATTmW
MEGAVOLT-AMPEREMVA
MILLIVOLTMV
MANUAL TRANSFER SWITCHMTS
MOUNTEDMTD
MAX OVERCURRENT PROTECTIONMOP
MOTOR OPERATED DAMPERMOD
MAX OVERCURRENT PROTECTIONMOCP
MAIN LUGS ONLYMLO
MISCELLANEOUSMISC
MINIMUM OR MINUTEMIN
MICROPHONEMIC
MEGAHERTZMHz
MANHOLE OR METAL HALIDEMH
MOTOR GENERATORMG
MANUFACTURERMFR
GROUND FAULT CIRC INTERRUPTERGFCI
GENERATORGEN
GENERAL CONTRACTORGC
GROUNDG
FULL VOLTAGE REVERSINGFVR
FULL VOLTAGE NON-REVERSINGFVNR
FEET OR FOOTFT
FREQUENCYFREQ
FIRE PROTECTION CONTRACTORFPC
FACTORY MUTUALFM
FLOORFLR
FULL LOAD AMPSFLA
FROM FLOOR BELOWFFB
FROM FLOOR ABOVEFFA
FEDERALFED
FEEDERFDR
FOOTCANDLEFC
FIRE ALARM CONTROL PANELFACP
FIRE ALARM ANNUNCIATOR PANELFAAP
FIRE ALARMFA
FAHRENHEITF
EXISTINGEXST or EXIST
EACH WAYEW
AND SO FORTH or ET CETERAETC
EQUIVALENTEQUIV
EQUIPMENTEQUIP
EQUALEQ
EXPLOSION PROOFEP
EMERGENCY POWER OFFEPO
ENVIR PROTECTION AGENCYEPA
ELECTRICALLY OPERATEDEO
ENCLOSUREENCL
ENERGY MANAGEMENT SYSTEMEMS
ELECTROMAGNETIC INTERFERENCEEMI
EMERGENCYEMER
ELECTRICELEC
EFFICIENCYEFF
ELECTRICAL CONTRACTOREC
EACHEA
EAST OR EMERGENCYE
DRAWINGDWG
DOUBLE THROWDT
DOUBLE POLE, SINGLE THROWDPST
DOUBLE POLE, DOUBLE THROWDPDT
DOWNDN
DAMP LOCATIONDL
DIVISIONDIV
DISTRIBUTIONDISTR
DISCONNECTDISC
DIAMETERDIA
DEMOLITIONDEMO
DEGREES FAHRENHEITDEG F
DEGREES CELSIUSDEG C
DEGREEDEG
DIRECT DIGITAL CONTROLDDC
DIRECT CURRENTDC
DECIBELDB
DEEP or DEPTHD
CUBIC YARDCU YD
CUBIC FEETCU FT
COPPERCU
CURRENT TRANSFORMERCT
COLOR RENDERING INDEXCRI
CONTROL POWER TRANSFORMERCPT
COMMUNICATIONCOMM
COLUMNCOL
COAXIAL CABLECOAX
COMPANYCO
CONCRETE MASONRY UNITCMU
CEILINGCLG
CURRENT LIMITING FUSECLF
CENTER LINECL
CUBIC FEET PER MINUTECFM
CLOSED CIRCUIT TELEVISIONCCTV
CIRCUIT BREAKERCB
COMMUNITY ANTENNA TELEVISIONCATV
CELSIUS OR CONDUITC
BOTTOM OF STEELBOS
BELOWBLW
BUILDINGBLDG
BREAKERBKR
BACKBOARDBKBD
BRAKE HORSEPOWERBHP
BELOW FINISHED GRADEBFG
BELOW FINISH FLOORBFF
BUILDING AUTOMATION SYSTEMBAS
AMERICAN WIRE GAUGEAWG
AVERAGEAVG
AUDIO VISUALAV
AUXILIARYAUX
AUTOMATIC TRANSFER SWITCHATS
AUTOMATIC TEMP CONTROLATC
AMPERE TRIPAT
APPROXIMATEAPPROX
AMPEREAMP
ALTERNATE NUMBERALT NO
ALTERNATEALT
AMPERE INTERRUPTING CAPACITYAIC
AUTHORITY HAVING JURISDICTIONAHJ
ABOVE FINISHED SLABAFS
ABOVE FINISHED ROOFAFR
ABOVE FINISHED GRADEAFG
ABOVE FINISHED FIRST FLOORAFFF
ABOVE FINISHED FLOORAFF
ABOVE FINISHED COUNTERAFC
AMERICANS WITH DISABILITIES ACTADA
ALTERNATING CURRENTAC
ABBREVIATIONABBRV
ARCHITECT/ENGINEERA/E
AMPEREA
FOUR-WIRE4W
FOUR-POLE SINGLE THROW4PST
FOUR-POLE DOUBLE THROW4PDT
FOUR-CONDUCTOR4/C
THREE-PHASE3Ø
THREE-PHASE3PH
THREE-CONDUCTOR3/C
TWO-WAY2WAY
TWO-CONDUCTOR2/C
SINGLE POLE1P
SINGLE-PHASE1Ø
SINGLE-PHASE1PH
NUMBERNO
ELECTRICAL ABBREVIATIONS EQUIPMENT ABBRV
AMPERE FRAMEAF
SHIELDED TWISTED PAIRSTP HOT WATER PUMPHWP
HOT WATER CIRC PUMPHWCP
HEAT RECOVERY UNITHRU
HEAT PUMPHP
HEATING COILHC
HUMIDIFIERH
GAS FIRED UNIT HEATERGUH
FUEL OIL PUMPFOP
FAN COIL UNITFCU
ELECTRIC WATER COOLEREWC
ELECTRIC UNIT HEATEREUH
ENERGY RECOVERY UNITERU
ELEVATORELEV
ELECTRIC HEATING PANELEHP
ELECTRIC HAND DRYEREHD
ELECTRIC HEATING COILEHC
EXHAUST FANEF
EVAPORATIVE COOLING UNITECU
ELECTRIC BASEBOARDEBB
DOMESTIC WATER HEATERDWH
DUCT HEATERDH
CABINET UNIT HEATERCUH
CONDENSING UNITCU
COOLING TOWERCT
CHILLED WATER PUMPCHWP
CHILLERCH
CHEMICAL FEED UNITCFU
BOILER FEEDWATER PUMPBFWP
BLOWER COIL UNITBC
BOILERB
AIR HANDLING UNITAHU
MOUNTING HEIGHTS
GENERAL ELECTRICAL NOTES
WIRE SEPARATION NOTES
1. ANALOG, DIGITAL, AND LOW VOLTAGE POWER CIRCUITS TO BE RUN IN SEPARATE RACEWAYS OR
CABLE SETS AS INDICATED.
2. SEPARATE WIRING BY LEVEL AS OUTLINED BELOW:
LEVEL 1-1 ANALOG SIGNALS LESS THAN 50V AND LESS THAN 50mA 4-20mA SHIELDED INSTRUMENTATION.
SHIELDED LOW VOLTAGE INSTRUMENTATION.
VARIABLE SPEED DRIVE SPEED SIGNALS.
LEVEL 1-2 DIGITAL SIGNAL AND DATA BUSSES.
PROGRAMMABLE LOGIC CONTROLLER BUSSES.
METER SYSTEM DATA BUS.
INSTRUMENTATION REMOTE TERMINAL UNIT BUS.
LEVEL 2-1 ANALOG SIGNALS OVER 50V AND LESS THAN 240V.
TACHOMETER GENERATORS.
LEVEL 2-2 DIGITAL AND DISCRETE INPUTS TO PROGRAMMABLE LOGIC CONTROLLERS AND
REMOTE TERMINAL UNITS. ALL OUTPUTS SUPPLYING RELAY COILS SHALL HAVE SURGE
SUPPRESSION.
LEVEL 3-1 POWER CIRCUITS OF 20A OR LESS AND 120V OR LESS.
LIGHTING AND RECEPTACLE CIRCUITS TO BE IN A SEPARATE CONDUIT UNO.
CLASS 1 CONTROL CIRCUITS ORIGINATING IN AN MCC COMPARTMENT OR A MOTOR
STARTER CAN BE ROUTED WITH POWER CIRCUIT FROM SAME COMPARTMENT.
LEVEL 4-1 POWER CIRCUITS OVER 20A UP TO 400A, LESS THAN 600V. EACH SHALL BE RUN IN
SEPARATE CONDUITS.
LEVEL 5-1 FEEDERS OVER 400A.
3. EACH LEVEL INDICATED ABOVE TO BE INSTALLED IN SEPARATE RACEWAY OR CABLE SET
UNLESS NOTED OTHERWISE OR INDICATED BY THESE CONTRACT DOCUMENTS.
4. WHERE DIFFERENT LEVEL SYSTEMS ARE INSTALLED IN PARALLEL RUNS EXCEEDING FIVE (5)
FEET OR LONGER, PROVIDE PHYSICAL SEPARATION AS SHOWN IN THE TABLE.
5. IN ALL JUNCTION/PULL BOXES WITH MULTIPLE VOLTAGES, PROVIDE GROUNDED METALLIC
BARRIERS TO MAINTAIN SEPARATION.
6. ONLY EXTERNAL INTERFACE SIGNALS ARE SHOWN FOR MOTOR/CONTROLLER STARTERS,
PROGRAMMABLE DEVICES, AND VARIABLE SPEED DRIVES (VFD). INTERNAL SIGNALS NECESSARY
FOR CORRECT FUNCTIONING MUST BE PROVIDED AND COORDINATED WITH ALL REQUIREMENTS.
7. ALL INTERCONNECTING WIRING AND TERMINATIONS BETWEEN EQUIPMENT BY CONTRACTOR
UNO.
8. CONTRACTOR SHALL PROVIDE THE OWNER WITH A FULL SIZE SET OF LOOP AND INTERFACE
WIRING DIAGRAMS WITH FILLED IN TERMINAL BLOCK AND WIRE NUMBERS.
9. REFER TO WIRE SEPARATION NOTED FOR COMBINING WIRING.
LIGHTING
EMERGENCY BATTERY UNIT - WALL
18" BELOW CEILING OR 8'-0" ABOVE FINISHED FLOOR, WHICHEVER IS
LOWER
EMERGENCY LIGHT - REMOTE HEAD
12" BELOW CEILING OR 8'-0" ABOVE FINISHED FLOOR, WHICHEVER IS
LOWER
EXIT SIGN - WALL
6" ABOVE DOOR JAMB BUT NO HIGHER THAN 8'-0" ABOVE FINISHED
FLOOR
LIGHT FIXTURE - WALL
SEE SPECIFICATIONS OR LIGHT FIXTURE SCHEDULE FOR MOUNTING
HEIGHT
LIGHTING CONTROL PANEL - WALL
TOP OF TRIM 6'-0" ABOVE FINISHED FLOOR. IF CABINET IS OVER 6'-0"
TALL, MOUNT BOTTOM EDGE 6" ABOVE FINISHED FLOOR
WIRING DEVICES
CLOCK RECEPTACLE
7'-0" ABOVE FINISHED FLOOR
MOTION SENSOR - WALL
8'-0" ABOVE FINISHED FLOOR OR AS RECOMMENDED BY
MANUFACTURER
PHOTOELECTRIC CELL - WALL
12" FROM TOP OF ROOM ON NORTH FACE OF BUILDING
PUSHBUTTON - WALL
SAME AS LIGHTING SWITCHES
RECEPTACLE - WALL
RECEPTACLES OCCURRING IN STRUCTURAL TILE, BRICK, OR BLOCK
WALL SHALL BE LOCATED ABOVE MASONRY JOINTS NEAREST THE
APPROPRIATE MOUNTING HEIGHT AS INDICATED BELOW
FINISHED SPACE STANDARD
18" ABOVE FINISHED FLOOR. WHERE INTERFERENCE WITH HEATING
EQUIPMENT REQUIRES HIGHER MOUNTING, MOUNT AS DIRECTED BY
THE ENGINEER
COUNTERS
6" ABOVE BACK SPLASH OR COUNTER. CONSTRUCTION OF COUNTERS
AND HEIGHTS OF BACKS SHALL BE VERIFIED BY THE CONTRACTOR
BEFORE ROUGH-IN
UNFINISHED SPACE
42" ABOVE FINISHED FLOOR EXCEPT WHERE INTERFERENCE WITH
MECHANICAL EQUIPMENT REQUIRES HIGHER MOUNTING
EXTERIOR - WALL
24" ABOVE FINISHED FLOOR. IF RECEPTACLE IS LESS THAN 24" ABOVE
FINISHED GRADE, INCREASE MOUNTING HEIGHT TO MAINTAIN 24"
ABOVE FINISHED GRADE
ROOF - WALL
24" ABOVE FINISHED FLOOR
RECEPTACLE - SPECIAL PURPOSE
SAME AS RECEPTACLES
SWITCH - LIGHTING
42" ABOVE FLOOR ON STRIKE SIDE OF DOOR. WHERE SWITCHES OCCUR
IN BRICK, TILE, OR…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .