23-65RP Appendix A
529 KB Posted
- Attached to
- Cauley Creek Park Fiber Network & Camera Install
- Solicitation number
- 23-065RP
- Issued by
- Fulton County, Georgia
About this file
This is an appendix to a Request for Proposals (RFP) issued by the City of Johns Creek, Georgia, detailing cable and device specifications for the Cauley Creek Park Fiber Network & Camera Installation Project. The project involves installing singlemode fiber backbone infrastructure to three park buildings: the main park office (#1), concession building (#2), and west side 5K facility (#3), with fiber runs ranging from approximately 400 feet to 2,700 feet in length. Additionally, composite fiber will connect to existing Corning ONE SDN infrastructure at city hall to deliver power and data across the three locations. The project requires installation of Category 6a cabling in all three buildings to support camera systems. Camera specifications call for ten Avigilon units across the three locations (five 20C-H4A-4MH-360 models and five 9C-H4A-3MH-270 models) with appropriate mounting accessories, one Aruba AP-575 outdoor access point at the 5K building, and one future wireless access point drop at the concession stand. The RFP deadline for sealed proposals was March 6, 2023, with the question deadline of February 21, 2023. Submissions were managed through BidNet, the Georgia Purchasing Group's online bidding system.
The specification document does not contain information regarding pricing terms, contract duration, funding sources, or award details. The City of Johns Creek reserves the right to reject any or all bids and to award the contract in its best interest. The project must comply with Title VI of the Civil Rights Act of 1964 and non-discrimination requirements for disadvantaged business enterprises as defined in 49 CFR Part 23. Vendors are required to work with Corning to determine appropriate composite fiber cable specifications based on distance and power requirements. Tentative equipment locations are referenced in Appendix B, and cable locations are detailed in the same appendix.
Text of this file
Appendix A – Cable and Device Specifications
Cable Specifications
Singlemode Fiber:
A singlemode fiber backbone will be installed in existing conduit to the concession building (#3), approximately 2200 ft in length, and the west side 5K facility (#2), approximately 2700ft in length. Both fiber runs will originate from the main park office (#1). Corning 6 stand OSP SM fiber with 12 gauge tracer wire will be used for this project. See Appendix B for cable locations.
Composite Fiber:
Hardware and composite fiber to connect to our existing Corning ONE SDN infrastructure that resides at city hall to deliver power and data to two locations on building #1 (runs totaling approximately 1600ft. in length), two locations from building #2 (runs totaling approximately 2500 ft), and one location from building #3 (run approximately 400 ft). Vendor will work with Corning to spec the appropriate cable specifications based on distance and power requirements. See Appendix B for cable locations.
CAT6a Specifications
Three Category 6a cables will need to be run in building #1 to connect three cameras, three in building
#2 and four at building #3, tentative locations identified in Appendix B.
Camera/Access Point Specifications
Main Park Office (#1)
Quantity (2): Avigilon 20C-H4A-4MH-360 and associated mounting accessories with pole
Quantity (2): Avigilon 9C-H4A-3MH-270 and associated exterior mounting accessories
Quantity (1): Avigilon 20C-H4A-4MH-360 and associated exterior mounting accessories
Concession Stand (#2)
Quantity (2): Avigilon 20C-H4A-4MH-360 and associated pole mounting accessories
Quantity (2): Avigilon 9C-H4A-3MH-270 and associated exterior mounting accessories
Quantity (1): Drop only for future Wireless Access Point
5K Building (#3)
Quantity (1): Avigilon 20C-H4A-4MH-360 and associated mounting accessories with pole
Quantity (3): Avigilon 9C-H4A-3MH-270 and associated wall mounting accessories
Quantity (1): Aruba AP-575 Outdoor Access Point with wall mounting accessories
Other files
| File | Type | Posted |
|---|---|---|
| 23-65RP Appendix D | — | |
| Award Information | — | |
| 23-65RP Addendum 2 | — | |
| 23-065RP Communication #1 | — | |
| 23-65RP Bid Packet | — | |
| 23-065RP COmmunication 2 | — | |
| 23-065RP Appendix A2 | — | |
| 23-065RP Addendum 1 | — |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .