23-0040 APPD.pdf
PDF 216 KB Posted
- Solicitation number
- N4008527R9000
About this file
This document is Appendix D: Building Information Checklist, a federal contracting template for collecting real property facility data required for entry into a real property database system.
The checklist is organized into five sections covering comprehensive building information for facility N40085-15-D-0815, Building 575 (Motor T), a single-story structure with 67,228 gross square feet and 64,500 net square feet. Section 1 documents building dimensions and construction materials, including existing dimensions, ceiling heights (7'-0" main building), door specifications (3'-0" width, varying heights), fire rating (Type IIB, F, S, and B occupancy), and material composition (CMU principal structure, steel frame secondary, brick and EIFS exterior, drywall/tile/CMU interior, concrete/tile/carpet flooring, standing seam metal roof with 3-ply modified bitumen surface). Section 2 addresses utility connections and fuel data, noting existing water, gas, and sewer infrastructure with three 4-inch communications pipes connected. Energy systems include gas heating with forced air circulation, electric air conditioning from main panel with forced air circulation, gas hot water, and electric service with two main panels (PANEL MPD: 480/277VAC, 600A; PANEL 4PD1: 120/208VAC, 400A) plus one transformer (T1: 480-208/120V, 5KVA). Section 3 catalogs building systems, including automated fire detection and manual fire alarm systems, 33.05-ton central air conditioning, and no emergency generator backup. Section 4 inventories installed equipment such as one 100-gallon hot water heater, one exhaust fan, nine wash basins, 19 water closets, 14 urinals, 12 gas-fired radiant heaters, five boilers (399.9 MBH each), eight showers, and six emergency showers. Section 5 documents associated utilities and structures including existing electrical transformers, 34 exterior wall-mounted lighting fixtures, 342 linear feet of sanitary sewer, 128 linear feet of water distribution mains, 50 square yards of driveway patching, 247 linear feet of telephone duct, and 9 square yards of concrete equipment pads.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0001.pdf | ||
| Pricing Sheet.pdf | ||
| RFP 230040.pdf | ||
| N4008523B0040 SpecsSigned.pdf | ||
| N4008523B0040 DwgsSigned.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UFC 1-300-08
30 JUNE 2004Const. Contract No:
APPENDIX D
BUILDING INFORMATION CHECKLIST
Use Appendix D as a checklist of required information to be entered into the real property database. Provide this information for each Real Property Facility listed on the DD Form 1354 in a format that allows easy data entry into the real property system. Normally this information is provided by the A/E electronically, often in XML format or GIS compatible format.
BUILDING IDENTIFICATION for this 5-Part CHECKLIST
Facility Number Building Name Number of Floors Gross SF Net SF
1. Building Dimensions and Construction Materials
Building Outside Dimensions Length (LF) Width (LF)
Main Building
Wings
Offsets
Basement
Attic
Porches, covered
Roof
Foundation
Other Building Data Feet
Ceiling Height Main Bldg.
Ceiling Height Basement
Door Height
Door Width
Code
Fire Rating Code
Construction Materials Type Principal Structural Material
Secondary Structural Material
Exterior Wall Material
Interior Wall Material
Floor Surface Material
Sub-Floor Material
D-1
30 JUNE 2004
Additional Construction Materials Type
Foundation Form Pile or Foundation Material
Foundation
Roof Type Roof Material
Roof Support
Roof Deck
Roof Surface
Construction Materials (Pavements) Type
Surface Course Materials
Base Course Materials
2. Utility Connections, Information and Fuel Data
Utility Connections
Number of Pipes
Diameter of each pipe
Capacity of all inlet pipes
Available or Connected?
(Yes/No)
Water
Gas
Sewer Pipe
Storm Sewer Pipe
Steam
Condensate
Communications
System Energy Type
Source Location
Fuel Description Air Circulation
Heating
Air Conditioning
Hot Water
Steam
Electrical
Electric Phase Voltage Wire Size
Connected Load - AMPS
Connected Load - KVA
D-2
3. Building Systems
Nomenclature UM Amount of UM Description
Fire Protection System
Closed Head Auto Sprinkler HD
Open Head Deluge System HD
Auto Fire Detection System HD
Manual Fire Alarm System EA
CO2 Fire System EA
Foam Fire System EA
Other Fire System EA
Halon 1301 Fire System EA
Security System
Security Alarm System EA
Heating System
Heating Plant MB
Storage Tank for Heating Fuel GA
Air Conditioning System
Central A/C Plant TN
Electrical System
Emergency Electrical Power Generator KW/KVA
Storage Tank for Generator Fuel GA
Hot Water
D-3
4. Installed Building Equipment (Real Property)
Item Size/Quantity Units Model Description
Evaporative Coolers CFM
Hot Water Heater GA
Exhaust Fan CFM
Wash Basin EACH
Water Closet EACH
Urinal EACH
Utility Sink EACH
Refrigerated Drinking Fountain EACH
Heating Plant Under 750 MB/Hr MB
Forced Air Heating BTU
Other Heating BTU
Dehumidifiers GPM
Elevators LBS & PN
Theater-type Seats, bolted to floor PN
Other (SPECIFY)
D-4
5. Checklist for Associated Utilities and Structures to be specifically listed as an item on DD Form 1354, column 10, if part of the project.
Nomenclature UM Amount of UM Cost Comments
Primary Elect. Distr. Line OH LF
Transformers KVA
Power Poles EA
Secondary Elect. Distr. Line OH LF
Exterior Street Lighting or Parking Area Lights EA
Gas Mains LF
Septic Systems KG
Sanitary Sewer LF
Water Distr. Mains LF
Fire Hydrants EA
Curbs & Gutters LF
Driveway SY
Roadway SY
Vehicle Parking SY
Storm Drain LF
Fence, Security LF
Fence, Interior LF
Sidewalk SY
Transformer Vault (four or more transformers) SF
Telephone Duct LF
Telephone Pole LF
Bridge Abutment EA
D5
Untitled
30 JUNE 2004
APPENDIX D
BUILDING INFORMATION CHECKLIST
Use Appendix D as a checklist of required information to be entered into the real property database. Provide this information for each Real Property Facility listed on the DD Form 1354 in a format that allows easy data entry into the real property system. Normally this information is provided by the A/E electronically, often in XML format or GIS compatible format.
BUILDING IDENTIFICATION for this 5-Part CHECKLIST Facility Number Building Name Number of Floors Gross SF Net SF
1. Building Dimensions and Construction Materials Building Outside Dimensions Length (LF) Width (LF) Main Building Wings Offsets Basement Attic Porches, covered Roof Foundation Other Building Data Feet Ceiling Height Main Bldg.
Ceiling Height Basement Door Height Door Width Code Fire Rating Code Construction Materials Type Principal Structural Material Secondary Structural Material Exterior Wall Material Interior Wall Material Floor Surface Material Sub-Floor Material D-1
UFC 1-300-08
30 JUNE 2004
Additional Construction Materials Type Foundation Form Pile or Foundation Material Foundation Roof Type Roof Material Roof Support Roof Deck Roof Surface Construction Materials (Pavements) Type Surface Course Materials Base Course Materials
2. Utility Connections, Information and Fuel Data Utility Connections Number of Pipes Diameter of each pipe Capacity of all inlet pipes Available or Connected?
(Yes/No) Water Gas Sewer Pipe Storm Sewer Pipe Steam Condensate Communications System Energy Type Source Location Fuel Description Air Circulation Heating Air Conditioning Hot Water Steam Electrical Electric Phase Voltage Wire Size Connected Load - AMPS Connected Load - KVA D-2
UFC 1-300-08
30 JUNE 2004
3. Building Systems Nomenclature
UM
Amount of UM Description Fire Protection System Closed Head Auto Sprinkler
HD
Open Head Deluge System
HD
Auto Fire Detection System
HD
Manual Fire Alarm System
EA
CO2 Fire System
EA
Foam Fire System
EA
Other Fire System
EA
Halon 1301 Fire System
EA
Security System Security Alarm System
EA
Heating System Heating Plant
MB
Storage Tank for Heating Fuel
GA
Air Conditioning System Central A/C Plant
TN
Electrical System Emergency Electrical Power Generator
KW/KVA
Storage Tank for Generator Fuel
GA
Hot Water D-3
UFC 1-300-08
30 JUNE 2004
4. Installed Building Equipment (Real Property) Item Size/Quantity Units Model Description Evaporative Coolers
CFM
Hot Water Heater
GA
Exhaust Fan
CFM
Wash Basin
EACH
Water Closet
EACH
Urinal
EACH
Utility Sink
EACH
Refrigerated Drinking Fountain
EACH
Heating Plant Under 750 MB/Hr
MB
Forced Air Heating
BTU
Other Heating
BTU
Dehumidifiers
GPM
Elevators
LBS & PN
Theater-type Seats, bolted to floor
PN
Other (SPECIFY) D-4
UFC 1-300-08
30 JUNE 2004
5. Checklist for Associated Utilities and Structures to be specifically listed as an item on DD Form 1354, column 10, if part of the project.
Nomenclature
UM
Amount of UM Cost Comments Primary Elect. Distr. Line OH
LF
Transformers
KVA
Power Poles
EA
Secondary Elect. Distr. Line OH
LF
Exterior Street Lighting or Parking Area Lights
EA
Gas Mains
LF
Septic Systems
KG
Sanitary Sewer
LF
Water Distr. Mains
LF
Fire Hydrants
EA
Curbs & Gutters
LF
Driveway
SY
Roadway
SY
Vehicle Parking
SY
Storm Drain
LF
Fence, Security
LF
Fence, Interior
LF
Sidewalk
SY
Transformer Vault (four or more transformers)
SF
Telephone Duct
LF
Telephone Pole
LF
Bridge Abutment
EA
D5 8.0.1291.1.339988.308172 Print Form
Const. Contract No:
APPENDIX D
BUILDING INFORMATION CHECKLIST
Use Appendix D as a checklist of required information to be entered into the real property database. Provide this information for each Real Property Facility listed on the DD Form 1354 in a format that allows easy data entry into the real property system. Normally this information is provided by the A/E electronically, often in XML format or
GIS compatible format.
BUILDING IDENTIFICATION for this 5-Part CHECKLIST
Facility
Number Building Name
Number of Floors Gross SF Net SF
FC255
FC255 MOTOR T
58,179 56,000
1. Building Dimensions and Construction Materials
Building Outside
Dimensions Length (LF) Width (LF) Main Building
EXISTING
EXISTING
Wings Offsets Basement Attic Porches, covered N/A Roof N/A Foundation N/A Other Building Data Feet Ceiling Height Main Bldg.
EXISTING
Ceiling Height Basement N/A Door Height 7'-0" Door Width
3'-0" VARIES
Code Fire Rating Code
TYPE IIB, F, S, AND B OCCUPANCY
Construction Materials Type Principal Structural Material
CMU
Secondary Structural Material
STEEL FRAME
Exterior Wall Material
BRICK, EIFS
Interior Wall Material
DRYWALL, TILE, CMU
Floor Surface Material
CONCRETE, TILE, CARPET
Sub-Floor Material N/A D-1
Additional Construction Materials Type Foundation Form Pile or Foundation Material Foundation
EXISTING
EXISTING
Roof Type Roof Material Roof Support
EXISTING
STANDING SEAM METAL
Roof Deck
EXISTING
Roof Surface
EXISTING
3-PLY MOD BIT
Construction Materials
(Pavements) Type Surface Course Materials
CONCRETE, ASPHALT
Base Course Materials
GRAVEL
2. Utility Connections, Information and Fuel Data
Utility
Connections
Number of
Pipes
Diameter of each pipe
Capacity of all inlet pipes
Available or
Connected?
(Yes/No) Water
1.5" PVC
YES
Gas 3/4"
EXISTING
YES
Sewer Pipe 4"
YES
Storm Sewer Pipe N/A Steam N/A Condensate Communications 4"
YES
System
Energy
Type
Source
Location
Fuel
Description Air Circulation Heating
GAS
METER
GAS
FORCED AIR
Air Conditioning
ELECTRIC
MAIN PANEL
N/A
FORCED AIR
Hot Water
GAS
METER
GAS
Steam N/A Electrical
ELECTRIC
METER
N/A Electric Phase Voltage
Wire
Size
Connected
Load - AMPS
Connected
Load - KVA
PANEL 4MPD
3 PHASE
120/208
4 WIRE
600A
PANEL 4PD1
3 PHASE
120/208
4 WIRE
400A T1
3 PHASE
480-208/120V
4 WIRE
5KVA
D-2
3. Building Systems Nomenclature
UM
Amount of UM Description Fire Protection System Closed Head Auto Sprinkler
HD
TBD
Open Head Deluge System
HD
N/A Auto Fire Detection System
HD
YES
Manual Fire Alarm System
EA
YES
CO2 Fire System
EA
Foam Fire System
EA
N/A Other Fire System
EA
Halon 1301 Fire System
EA
N/A Security System Security Alarm System
EA
N/A Heating System Heating Plant
MB
N/A Storage Tank for Heating Fuel
GA
N/A Air Conditioning System Central A/C Plant
TN
33.05 Electrical System
Emergency Electrical Power
Generator
KW/KVA
N/A Storage Tank for Generator Fuel
GA
N/A Hot Water D-3
4. Installed Building Equipment (Real Property) Item Size/Quantity Units Model Description Evaporative Coolers N/A
CFM
Hot Water Heater
(1) 100 GALLON
GA
10 GAL EXP. TANK
Exhaust Fan (1)
CFM
PV-09
Wash Basin (7)
EACH
6 WALL, 1 MULTI,
Water Closet (15)
EACH
1.6/1.1 GPF
Urinal (9)
EACH
.5 GPF
Utility Sink (2)
EACH
Refrigerated Drinking Fountain (2)
EACH
Heating Plant Under
750 MB/Hr N/A
MB
Forced Air Heating
BTU
Other Heating (4)
BTU
BOILERS 399.9 MBH
Dehumidifiers N/A
GPM
Elevators
LBS & PN
Theater-type Seats, bolted to floor N/A
PN
Other (SPECIFY) (7)
SHOWER
(6) D-4
5. Checklist for Associated Utilities and Structures to be specifically listed as an item on DD
Form 1354, column 10, if part of the project.
Nomenclature
UM
Amount of UM Cost Comments Primary Elect. Distr. Line OH
LF
Transformers
KVA
150KVA
Power Poles
EA
N/A Secondary Elect. Distr. Line OH
LF
Exterior Street Lighting or Parking
Area Lights
EA
WALL MOUNTED
Gas Mains
LF
N/A Septic Systems
KG
N/A Sanitary Sewer
LF
342' Water Distr. Mains
LF
128' Fire Hydrants
EA
N/A Curbs & Gutters
LF
N/A Driveway
SY
PATCHING
Roadway
SY
N/A Vehicle Parking
SY
N/A Storm Drain
LF
N/A Fence, Security
LF
N/A Fence, Interior
LF
N/A Sidewalk
SY
N/A Transformer Vault (four or more transformers)
SF
N/A Telephone Duct
LF
Telephone Pole
LF
Bridge Abutment
EA
N/A
MULTIPLE
D5
| PrintButton1: |
| TextField1: |
N40085-15-D-0815 TextField2:
Bldg 575 TextField2:
Bldg 575 MOTOR T TextField2:
TextField2:
67,228 TextField2:
64,500 TextField3:
EXISTING
TextField3:
EXISTING
TextField3:
N/A TextField3:
TextField3:
N/A TextField3:
TextField3:
N/A TextField3:
TextField3:
N/A TextField3:
TextField3:
N/A TextField3:
TextField3:
N/A TextField3:
TextField3:
N/A TextField3:
TextField5:
EXISTING
TextField5:
N/A TextField5:
7'-0" TextField5:
3'-0" VARIES
TextField5:
TYPE IIB, F, S, AND B OCCUPANCY
TextField4:
CMU
TextField4:
STEEL FRAME
TextField4:
BRICK, EIFS
TextField4:
DRYWALL, TILE, CMU
TextField4:
CONCRETE, TILE, CARPET
TextField4:
N/A TextField6:
EXISTING
TextField6:
EXISTING
TextField7:
EXISTING
TextField7:
STANDING SEAM METAL
TextField7:
EXISTING
TextField7:
TextField7:
EXISTING
TextField7:
3-PLY MOD BIT
TextField8:
CONCRETE, ASPHALT
TextField8:
GRAVEL
TextField9:
EXISTING
TextField9:
TextField9:
TextField9:
TextField9:
EXISTING
TextField9:
TextField9:
TextField9:
TextField9:
EXISTING
TextField9:
TextField9:
TextField9:
TextField9:
N/A TextField9:
TextField9:
TextField9:
TextField9:
N/A TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
4" TextField9:
TextField9:
YES
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField9:
TextField10:
GAS
TextField10:
METER
TextField10:
GAS
TextField10:
FORCED AIR
TextField10:
ELECTRIC
TextField10:
MAIN PANEL
TextField10:
N/A TextField10:
FORCED AIR
TextField10:
GAS
TextField10:
METER
TextField10:
GAS
TextField10:
TextField10:
N/A TextField10:
TextField10:
TextField10:
TextField10:
ELECTRIC
TextField10:
METER
TextField10:
N/A TextField10:
TextField10:
TextField10:
TextField10:
TextField10:
TextField11:
PANEL MPD
TextField11:
3 PHASE
TextField11:
480/277VAC
TextField11:
4 WIRE
TextField11:
600A TextField11:
TextField11:
PANEL 4PD1
TextField11:
3 PHASE
TextField11:
120/208 TextField11:
4 WIRE
TextField11:
400A TextField11:
TextField11:
T1 TextField11:
3 PHASE
TextField11:
480-208/120V TextField11:
4 WIRE
TextField11:
5KVA
TextField11:
TextField12:
TBD
TextField12:
TextField12:
N/A TextField12:
TextField12:
YES
TextField12:
TextField12:
YES
TextField12:
TextField12:
TextField12:
TextField12:
N/A TextField12:
TextField12:
TextField12:
TextField12:
N/A TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
N/A TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
N/A TextField12:
TextField12:
N/A TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
33.05 TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
N/A TextField12:
TextField12:
N/A TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField12:
TextField13:
N/A TextField13:
TextField13:
TextField13:
(1) 100 GALLON
TextField13:
TextField13:
10 GAL EXP. TANK
TextField13:
(1) TextField13:
TextField13:
PV-09
TextField13:
(9) TextField13:
TextField13:
7 WALL, 2 MULTI-STATION SINK,
TextField13:
(19) TextField13:
TextField13:
1.6/1.1 GPF
TextField13:
(14) TextField13:
TextField13:
.5 GPF
TextField13:
(1) TextField13:
TextField13:
TextField13:
(5) TextField13:
TextField13:
TextField13:
N/A TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
GAS FIRED RADIANT HEATER
TextField13:
(5) TextField13:
TextField13:
BOILERS 399.9 MBH
TextField13:
N/A TextField13:
TextField13:
TextField13:
N/A TextField13:
TextField13:
TextField13:
N/A TextField13:
TextField13:
TextField13:
(8) TextField13:
TextField13:
TextField13:
SHOWER
TextField13:
Cooling TextField13:
TextField13:
TONS
TextField13:
TextField13:
TextField13:
Emergency Shower TextField13:
(6) TextField13:
EACH
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField13:
TextField15:
TextField15:
TextField15:
TextField15:
EXISTING
TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
WALL MOUNTED
TextField15:
N/A TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
342' TextField15:
TextField15:
TextField15:
128' TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
PATCHING
TextField15:
N/A TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
N/A TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
MULTIPLE
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField15:
TextField14:
Concrete Equipment Pad TextField14:
SY
TextField14:
TextField14:
TextField14:
TextField14:
TextField14:
TextField14:
File details come from the government source that posted it. Updated .