213-2324-009 Gill Health + PE - Ceiling & Lighting Upgrades - Drawings.pdf
PDF 20 MB Posted
- Solicitation number
- 62843
- Issued by
- Norfolk City, Virginia
About this file
This document appears to be a set of drawings related to a state and local contract opportunity in Virginia for the Gill Health + PE Building. The project will involve upgrading the existing lighting and lighting controls with new LED lighting, refreshing the interior painting, installing new branding graphics, a new acoustical ceiling, and other interior finishes. The project is located in Norfolk City. The document provides an overview of the scope of work and requirements, but does not include details on pricing, set asides, incumbents, funding sources, or other salient contract information.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOT IN
CONTRACTNOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
BRICK
ELEVATION
BRICK - PLAN
CMU - PLAN
CONCRETE
GROUT
GYPSUM
WALLBOARD
STEEL
INSUL - BATT
1t
DOOR TYPE
WINDOW TYPE
BUILDING/WALL/DETAIL SECTION #
SHEET # WHERE SECTION IS DRAWN
FLOOR LEVEL / ELEVATION
A101
Ref
1R e f
1 R e f
Ref
BUILDING ELEVATION TAG
SHEET # WHERE SECTION IS DRAWN
KEY NOTE
S1 WALL TYPE
ROOM TAG
ROOM #
ROOM SQUARE FOOTAGE
ALIGN
ENLARGED PLAN/DETAIL LOCATION
WITH SHEET TAKEN AND SHEET SHOWN
SIM
A102 A103
A101
SIM
PLAN NUMBER AND SHEET
EXISTING DOOR
TO REMAIN
A101
INTERIOR ELEVATION TAG
SHEET # WHERE ELEVATION IS DRAWN
1 Ref
R e f
1 Ref
R e f
SIM
A102A108
Room name
150 SF
Name Elevation
EXISTING PARTITION
TO BE DEMOLISHED
EXISTING PARTITION
TO REMAIN
NEW PARTITION
EXISTING DOOR TO
BE DEMOLISHED
NEW DOOR
OPEN TO
BELOW
OPEN TO
BELOW
NOT IN
CONTRACT
NOT IN
CONTRACT
VIRGINIA UNIFORM STATEWIDE BUILDING CODE 2018
VIRGINIA UNIFORM STATEWIDE EXISTING BUILDING CODE 2018
CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL 2023
VIRGINIA ENERGY CONSERVATION CODE COMPLIANCE STATEMENT
4. IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC), THE
BUILDING SHALL COMPLY WITH VECC SECTIONS C402 THROUGH C405 AND C408.
APPLICABLE CODES + STANDARDS
HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT
IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS
EXEMPT FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT
EXCEED 50% OF THE VALUE OF THE BUILDING
ASBESTOS DISCLOSURE STATEMENT
AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN
THE AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED
TO DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED
AS AN APPENDIX TO THE PROJECT SPECIFICATION
LEAD MATERIALS DISCLOSURE STATEMENT
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING
COMPONENTS HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT
SPECIFICATIONS. THIS REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND
MAY NOT BE ALL INCLUSIVE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY
WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS
THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED
BUILDING COMPONENTS SHALL BE RECYCLED TO THE EXTENT POSSIBLE.
GILL HEALTH + PE BUILDING CURRENTLY SERVES AS A HEALTH AND PHYSICAL
EDUCATION FACILITY HOUSING A GYMNASIUM, SWIMMING POOL, LOCKER
ROOMS, RESTROOMS, CLASSROOMS, AND OFFICES. THE GILL HEALTH + PE
BUILDING IS APPROXIMATELY 77,300 SF, WAS CONSTRUCTED IN 1961 AND IS
PRIMARILY A ONE STORY BUILDING WITH A PARTIAL SECOND FLOOR AROUND
THE GYMNASIUM PORTION OF THE BUILDING. THE BUILDING HAS LOAD BEARING
STEEL COLUMNS THAT SUPPORT THE UPPER FLOOR AND ROOF. THE ROOF IS
CONSTRUCTED OF METAL DECK SUPPORTED BY STEEL BEAMS AND OPEN WEB
STEEL JOISTS. THE ROOF OVER THE GYM IS A GABLE ROOF. EXTERIOR WALLS
CONSIST OF CONCRETE MASONRY WITH BRICK VENEER AND PRECAST
CONCRETE PANELS.
THIS PROJECT WILL UPGRADE THE EXISTING LIGHTING, LIGHTING CONTROLS,
CEILING + FLOOR + WALL FINISHES, AND GRAPHIC BRANDING. BUILDING WILL
REMAIN OCCUPIED BY OWNER DURING CONSTRUCTION.
PROJECT INFORMATION AND DESCRIPTION OF WORK
ANDREW JOHN
Lic No. 15101
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
T101
TITLE SHEET
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
GILL HEALTH & PE - CEILING, LIGHTING &
INTERIOR FINISHES UPGRADES
700 Park Ave, Norfolk, VA 23504
Norfolk State University
KEY PLANS
VICINITY MAP
LOCATION MAP
SHEET INDEX
ARCHITECT:
VIA DESIGN ARCHITECTS, PC
319 E PLUME STREET
NORFOLK, VA 23510
MECH., ELEC., PLUMB., ENGINEER:
COASTAL ENGINEERING, PLLC
2406 PRINCESS ANNE ROAD, #2
VIRGINIA BEACH, VA 23456
PROJECT TEAM
PROJECT IDENTIFICATION
STATE PROJECT NUMBER: 213-2324-009
VIA DESIGN PROJECT NUMBER: 20009-07
1/64" = 1'-0"A600 T101
1 LEVEL 1 - KEY PLAN
MATERIAL LEGEND ABBREVIATIONS
AFF
ACT
ARCH
CJ
CT
CONC
CONT
CMU
DEMO
DIA
DIM
DWG
EWC
EQ
FEC
GWB
ETR
ARCHITECTURAL SYMBOLS
AREA OF WORK
1/64" = 1'-0"A600 T101
2 LEVEL 2 - KEY PLAN
MFR
MO
MECH
MIN
NIC
NTS
OC
REF
RO
SIM
SPEC
STRUCT
TYP
UON
VIF
VWC
ABOVE FINISH FLOOR
ACOUSTICAL CEILING TILE
ARCHITECTURAL
CONTROL JOINT
CERAMIC TILE
CONCRETE
CONTINUOUS
CONCRETE MASONRY UNIT
DEMOLITION
DIAMETER
DIMENSION
DRAWING
ELECTRICAL WATER COOLER
EQUAL
FIRE EXTINGUISHER CABINET
GYPSUM WALL BOARD
EXISTING TO REMAIN
MANUFACTURER
MASONRY OPENING
MECHANICAL
MINIMUM
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
REFERENCE
ROUGH OPENING
SIMILAR
SPECIFICATION
STRUCTURAL
TYPICAL
UNLESS OTHERWISE NOTED
VERIFY IN FIELD
VINYL WALL COVERING
ARCHITECTURAL SERIES
AD101 LEVEL 1 - DEMO - FLOOR PLAN
AD102 LEVEL 2 - DEMO - FLOOR PLAN
AD103 LEVEL 1 - DEMO - REFLECTED CEILING PLAN
AD104 LEVEL 2 - DEMO - REFLECTED CEILING PLAN
MECHANICAL SERIES
ELECTRICAL SERIES
TITLE SERIES
T101 TITLE SHEET
T102 SHORT FORM SPECIFICATIONS
T103 SHORT FORM SPECIFICATIONS
T104 3D RENDERINGS
T105 GRAPHICS PACKAGE
LIFE SAFETY SERIES
LS101 LIFE SAFETY PLANS + CODE ANALYSIS
PLUMBING SERIES
A101 LEVEL 1 - NEW WORK - FLOOR PLAN
A102 LEVEL 2 - NEW WORK - FLOOR PLAN
A103 LEVEL 1 - NEW WORK - REFLECTED CEILING PLAN
A104 LEVEL 2 - NEW WORK - REFLECTED CEILING PLAN
A105 ROOF - NEW WORK - ROOF PLAN
A106 DEMO + NEW WORK - ENLARGED REFLECTED CEILING PLANS
A107 DEMO - ENLARGED REFLECTED CEILING PLAN
A108 NEW WORK - ENLARGED REFLECTED CEILING PLAN
A501 TYPICAL DETAILS
A502 RESTROOM AND ACCESSIBILITY DETAILS
A600 ENLARGED STAIR ELEVATIONS
A701 ENLARGED PLANS + INTERIOR ELEVATIONS
A702 ENLARGED PLANS + INTERIOR ELEVATIONS
A703 ENLARGED PLANS + INTERIOR ELEVATIONS
A704 ENLARGED PLANS + INTERIOR ELEVATIONS
A705 ENLARGED PLANS + INTERIOR ELEVATIONS
A706 ENLARGED PLANS + INTERIOR ELEVATIONS
A800 DOOR + FINISH TYPES, SCHEDULE, + DETAILS
P001 PLANS-DEMO,LEGEND, ABBREVIATIONS, NOTES, AND SCHEDULE
P401 LARGE-SCALE VIEWS, ABBREVIATIONS AND LEGEND
P701 SPECIFICATIONS
M102 LEVEL 1 FLOOR PLAN DEMO WORK AND NOTES
M102 LEVEL 2 FLOOR PLAN DEMO WORK
M201 LEVEL 1 FLOOR PLAN NEW WORK
M202 LEVEL 2 FLOOR PLAN NEW WORK
M701 MECHANICAL SPECIFICATIONS
E001 LEGEND, ABBREVIATIONS, NOTES, LIGHTING FIXTURE SCHEDULE
E101 LEVEL 1 FLOOR PLAN DEMO WORK - LIGHTING & MISC.
E102 LEVEL 2 FLOOR PLAN DEMO WORK - LIGHTING
E201 LEVEL 1 FLOOR PLAN NEW WORK - LIGHTING & MISC.
E203 LEVEL 2 FLOOR PLAN NEW WORK - LIGHTING & MISC.
E501 ELECTRICAL DETAILS
E601 PANEL SCHEDULES
E602 LIGHTING CONTROLS RISER #1
E603 LIGHTING CONTROLS RISER #2
E604 LIGHTING CONTROLS RISER #3
E605 LIGHTING CONTROLS AND WIRING DIAGRAM
E606 LIGHTING CONTROLS
E702 ELECTRICAL SPECIFICATIONS
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
IO
N
UPON DISCOVERY OF PENETRATED FIRE BARRIERS, CONTRACTOR TO REFER TO UNIT PRICES SPECIFICATION.
PENETRATIONS SMALLER THAN 1" ARE TO BE PATCHED WITH GROUT.
PENETRATIONS UP TO 4" ARE TO BE REPAIRED WITH FIRE FOAM.
PENETRATIONS UP TO 24" X 24", LOOSE OR MISSING BLOCK, ARE TO BE REPAIRED WITH NEW BLOCK.
ABOVE CEILING CMU REPAIR NOTES
ANDREW JOHN
Lic No. 15101
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
T102
SHORT FORM
SPECIFICATIONS
Checker
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
IO
N
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
T103
SHORT FORM
SPECIFICATIONS
Checker
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
T104
3D RENDERINGS
Checker
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
R E
N D
E R
IN
G
B R
E N
D E
R
IN
G A
R E
N D
E R
IN
G
D R
E N
D E
R
IN
G C
R E
N D
E R
IN
G
F R
E N
D E
R
IN
G E
R E
N D
E R
IN
G
G
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
T105
GRAPHICS PACKAGE
Checker
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
NSU TIMELINE
SPARTAN HEAD @ FOOTBALL LOCKERS
NORFOLK MAP
SPARTAN STRONGSPARTAN HEAD @ GYMNSU STATISTICS
GREEN + GOLD SLASHDOOR WRAP: WOMEN
DOOR WRAP: MEN
NSU TIMELINE
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
UP
UP
GYMNASIUM
SWIMMING
POOL
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
MECH
MECH.
OFFICE
116B
PUMP
MECH.
MECH.
OFFICE
OFFICE
OFFICE
STORAGE
GOLF
SIMULATOR
M E
C H
ROTC
176E
ROTC
R O
T C
D
ROTC
176C
ROTC
176B
ROTC
176A
CLO.
STORAGE
STORAGE
STORAGE
CLO.
OFFICE
WEIGHT
ROOM
COMPUTER
LAB
OFFICE
110A
OFFICE
CONF.
OFFICE
O F
F
IC
E
O F
F
IC
E
A
O F
F
IC
E
B
VESTIBULE
MEN'S
LOCKER
STAIR
STAIR
STAIR
STAIR
CLO.
VEST
VEST.
170D
VEST.
150A
CLO.
CLO.
CORRIDOR
CORRIDOR
CORRIDOR
CORRIDOR
CLO.
109B
CLO.
109A
CORRIDOR
168 VESTIBULE
170A
WOMEN'S RR
MEN'S RR
MECH.
CORRIDOR
FLEX
LOCKER
FLEX
RESTROOM
121A
FLEX
RESTROOM
119A
FLEX
LOCKER
WOMEN'S
LOCKER
LOCKER
VESTIBULE
LOCKER
SHOWER
COACHES'
SHOWER
COACHES'
LOCKER
VESTIBULE
S T
O R
A G
E
R E
S T
R O
O M
M E
N 'S
R R
W O
M E
N 'S
R R
VEST.
150BVEST.
190A
OFFICE
110B
JANITORS
CLO.
MECH
MECH.
VEST.
100A
VEST.
100B
OFFICE
OFFICE
CONF.
OFFICE
OFFICE
OFFICE
CONF.
OFFICE
211A
OFFICE
CORRIDOR
DANCE
STUDIO
OFFICE
STAIR
STAIR
VEST
STAIR
V E
S T
IB
U
L E
7 STAIR
OPEN TO
BELOW
OPEN TO
BELOW
OPEN TO
BELOW
OFFICE
GIRLS
LOCKER
ROOM
1 HOUR FIRE BARRIER
HORIZONTAL FIRE SEPARATION
ABOVE FINISH CEILING
WORK AREA SEPARATION LINE
ANDREW JOHN
Lic No. 15101
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
LS101
LIFE SAFETY PLANS + CODE
ANALYSIS
Checker
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
3/64" = 1'-0"A600 LS101
1 LEVEL 1 - LIFE SAFETY PLAN
3/64" = 1'-0"A600 LS101
2 LEVEL 2 - LIFE SAFETY PLAN
1/4" = 1'-0"
LIFE SAFETY LEGEND
CODE SUMMARY
RELEVANT CODES AND STANDARDS
VIRGINIA CONSTRUCTION CODE – 2018 (REFERENCED AS VCC)
VIRGINIA EXISTING BUILDING CODE – 2018 (REFERENCED AS VEBC)
THE EXISTING BUILDING:
• IS UNSPRINKLERED
• CONTAINS A FIRE ALARM SYSTEM
• CONTAINS SMOKE DETECTION - SMOKE DETECTION IS ALSO INCLUDED IN THE
NEW MECHANICAL SYSTEM
VIRGINIA CONSTRUCTION CODE - 2018
CHAPTER 3 - USE AND OCCUPANCY CLASSIFICATION
ASSEMBLY GROUP A-4 - INDOOR SWIMMING POOLS WITH SPECTATOR SEATING
ASSEMBLY GROUP A-4 - GYMNASIUMS WITH SPECTATOR SEATING
GYMNASIUMS WITH SPECTATOR SEATING ARE NOT SPECIFICALLY IDENTIFIED IN THE
VCC, BUT ARE MOST CLOSELY ALIGNED WITH GROUP A-4, INCLUDING "ASSEMBLY
USES INTENDED FOR VIEWING OF INDOOR SPORTING EVENTS AND ACTIVITIES WITH
SPECTATOR SEATING"
BUSINESS GROUP B - BUSINESS OFFICE AREAS AND EDUCATIONAL CLASSROOMS
FOR STUDENTS ABOVE THE 12TH GRADE
CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS
508.4 SEPARATED OCCUPANCIES
PER VCC TABLE 508.4 THE BUILDING SHALL BE CONSIDERED SEPARATED
OCCUPANCIES
NOTE: THE DESIGN TEAM HAS SPENT CONSIDERABLE TIME IN THE BUILDING
REVIEWING EXISTING DOOR RATINGS AND CONTINUITY OF PARTITIONS. ALL KNOWN
RATED PARTITIONS HAVE BEEN IDENTIFIED ON THE LIFE SAFETY PLANS. AREAS
THAT ARE NOT INDICATED AS RATED ARE A RESULT OF EITHER AN OPENING THAT IS
NOT PROTECTED BY A RATED DOOR, OR WALL CONSTRUCTION THAT DOES NOT
CONTINUE TO THE UNDERSIDE OF CONSTRUCTION ABOVE.
CHAPTER 6 - TYPES OF CONSTRUCTION
THE EXISTING BUILDING IS CLASSIFIED AS TYPE IIB
EXISTING BUILDING ELEMENTS ARE OF NONCOMBUSTIBLE MATERIALS, INCLUDING
THE PRIMARY STRUCTURAL FRAME, EXTERIOR BEARING WALLS, NONBEARING WALLS
ON THE INTERIOR AND EXTERIOR, NONBEARING WALLS AND PARTITIONS, FLOOR
CONSTRUCTION, AND ROOF CONSTRUCTION AND ASSOCIATED SECONDARY
MEMBERS.
EXISTING BUILDING ELEMENTS ARE NONCOMBUSTIBLE, AND ARE UNPROTECTED
THE NEW BUILDING ELEMENTS WILL UTILIZE SIMILAR MATERIALS
CHAPTER 8 - FINISHES
803.1.2 - INTERIOR WALL AND CEILING FINISH MATERIALS ARE SPECIFIED IN
ACCORDANCE WITH ASTM E84 OR UL 723
CLASS A = FLAME SPREAD INDEX 0-25; SMOKE-DEVELOPED INDEX 0-450
CLASS B = FLAME SPREAD INDEX 26-75; SMOKE-DEVELOPED INDEX 0-450
CLASS C = FLAME SPREAD INDEX 76-200; SMOKE-DEVELOPED INDEX 0-450
803.13 - INTERIOR FINISH REQUIREMENTS BASED ON OCCUPANCY
INTERIOR EXIT STAIRS CORRIDORS ROOMS/ENCLOSED SPACES
A-4 A A C B A B C
CHAPTER 3 – GENERAL PROVISIONS AND SPECIAL DETAILED REQUIREMENTS
301 - GENERAL
301.2 OCCUPANCY AND USE
OCCUPANCY AND USE IS DETERMINED PER CHAPTER 3 OF THE VCC
THERE ARE NO CHANGES TO OCCUPANCY AND USE AS A RESULT OF THIS PROJECT
302.1 - NEW AND REPLACEMENT MATERIALS
THE PROJECT WILL UTILIZE LIKE MATERIALS
302.3 SMOKE ALARMS
ALL SMOKE ALARMS ARE EXISTING TO REMAIN AND SHALL REMAIN OPERATIONAL AT
ALL TIMES DURING CONSTRUCTION.
CODE SUMMARY – VIRGINIA EXISTING BUILDING CODE – 2018 CONTINUED
CHAPTER 4 - ACCESSIBILITY
404 - ALTERATIONS
404.2 - ALTERATIONS
ACCESSIBILITY REQUIREMENTS SHALL COMPLY WITH THE CPSM, SECTION 4.2
ACCESSIBILITY STANDARDS FOR STATE-OWNED FACILITIES. THE PRESCRIBED
ACCESSIBILITY STANDARDS ARE THE DEPARTMENT OF JUSTICE’S 2010 ADA
STANDARDS FOR ACCESSIBLE DESIGN, DATED SEPTEMBER 15, 2010
THERE ARE NO ALTERATIONS TO BUILDING ELEMENTS THAT WILL AFFECT
ACCESSIBILITY AS A RESULT OF THIS PROJECT
CHAPTER 6 - ALTERATIONS
601.2 - LEVELS OF ALTERATIONS
601.2.1 LEVEL 1
LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE
COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES USING
NEW MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME
PURPOSE, OR THE REMOVAL WITHOUT REPLACEMENT OF MATERIALS, ELEMENTS,
EQUIPMENT, OR FIXTURES. LEVEL 1 ALTERATIONS SHALL COMPLY WITH THE
APPLICABLE PROVISIONS OF SECTION 602.
601.2.2 LEVEL 2
LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF
SECTIONS 602 AND 603 AND SHALL INCLUDE THE FOLLOWING:
1. THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW.
2. THE ADDITION OR ELIMINATION OF ANY WALL, FLOOR, OR CEILING ASSEMBLY.
3. THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM.
4. THE INSTALLATION OF ANY ADDITION, EQUIPMENT, MATERIALS, ELEMENTS
OR FIXTURES.
DOORS AND FINISH FLOORS WILL BE ELIMINATED AND ADDED AS A PART OF THIS
PROJECT. NO WINDOWS OR WALLS WILL BE ADDED OR ELIMINATED. ACT CEILING
ASSEMBLIES WILL BE REMOVED AND REPLACED IN SOME LOCATIONS AS PART OF
THE PROJECT. MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS WILL BE
MODIFIED AS PART OF THE PROJECT.
DUE TO PROPOSED ALTERATIONS TO THE BUILDING, THE WORK IS CLASSIFIED AS A
LEVEL 2 ALTERATION
601.4 ENERGY CONSERVATION
EXCEPT AS MODIFIED BY THIS SECTION, ALTERATIONS TO AN EXISTING
BUILDING, BUILDING SYSTEM OR STRUCTURE SHALL CONFORM TO THE APPLICABLE
PROVISIONS OF THE VIRGINIA ENERGY CONSERVATION CODE AS THEY RELATE TO
NEW CONSTRUCTION WITHOUT REQUIRING THE UNALTERED PORTIONS OF THE
EXISTING BUILDING, BUILDING SYSTEM, OR STRUCTURE TO COMPLY WITH THE
VECC.
602 - ALTERATION LEVEL 1
602.2 - CONFORMANCE
ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE
FOLLOWING:
1. LEVEL OF FIRE PROTECTION THAT IS EXISTING
2. LEVEL OF PROTECTION THAT IS EXISTING FOR THE MEANS OF EGRESS
FIRE PROTECTION AND MEANS OF EGRESS SHALL BE MAINTAINED
602.3 BUILDING ELEMENTS AND MATERIALS
602.3.1 INTERIOR FINISHES AND TRIM
ALL NEWLY INSTALLED INTERIOR FINISH AND TRIM MATERIALS AND WALL, FLOOR
AND CEILING FINISHES SHALL COMPLY WITH CHAPTER 8 OF THE VCC.
CHAPTER 7 - CHANGE OF OCCUPANCY
NO CHANGES TO THE OCCUPANCY CLASSIFICATION OF THE BUILDING WILL OCCUR
AS PART OF THIS WORK
CHAPTER 12 – CONSTRUCTION SAFEGUARDS
1201.4 MANNER OF REMOVAL
WASTE MATERIALS SHALL BE REMOVED IN A MANNER WHICH PREVENTS INJURY OR
DAMAGE TO PERSONS, ADJOINING PROPERTIES, AND PUBLIC RIGHTS-OF-WAY.
1201.5 FIRE SAFETY DURING CONSTRUCTION
FIRE SAFETY DURING CONSTRUCTION SHALL COMPLY WITH THE APPLICABLE
REQUIREMENTS OF THE VCC
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
UPUP
UP
UP
UP
UP
UP
E
F
D
C
B
G
H
A
STAIR
VEST.
150A
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
GYMNASIUM
CORRIDOR
STAIR
STAIR
STAIR
STAIR
CORRIDOR
CORRIDOR
VEST.
190A
CORRIDOR
168 VESTIBULE
170A
VEST.
100B
VEST.
100A
OFFICE
WOMEN'S RR
MEN'S RR
MECH.
VEST.
170D
CORRIDOR
MECH.
VEST.
150B
SWIMMING
POOL
ROTC
176E
ROTC
ROTC
176D
ROTC
176C
ROTC
176B
ROTC
176A
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
OFFICE
110A
CLO.
110C
CLO.
110D
OFFICE
C L
O
C
OFFICE
113A
OFFICE
113B
VESTIBULE
CORRIDOR
OFFICE
OFFICE
CONF.
COMPUTER
LAB
02 41 27
AD101 A701
02 41 28
02 41 28
02 41 23
02 41 16
02 22 11
02 41 24
02 41 27
02 41 27
02 41 26
02 22 19
02 22 19
02 22 20 02 22 20
02 22 20
02 41 23
OFFICE
110B
02 41 27
02 41 23
02 41 23
02 41 23
02 41 27
02 41 30
02 41 27
02 41 27
02 41 27
02 41 27
02 41 29
02 22 11
02 41 2902 41 29
02 41 29
02 41 29
02 41 2902 41 2902 41 29
02 41 27
02 41 26
02 41 2902 41 29
1. WHERE IT IS CALLED OUT TO PATCH AND REPAIR AREAS, NEW CONSTRUCTION
IS TO MATCH ADJACENT CONSTRUCTION.
2. WHERE EXISTING DOORS AND WINDOWS ARE REQUIRED TO BE DEMOLISHED,
CAREFULLY SAW CUT FRAMING MEMBERS AND REMOVE AS REQUIRED.
3. WHERE PLUMBING OR ELECTRICAL FIXTURES ARE TO BE DEMOLISHED
CAREFULLY CAP ALL WATER LINES, CONDUIT, AND ALL WIRING BEFORE
REMOVAL.
4. IF HAZARDOUS MATERIAL IS SUSPECTED, CONTRACTOR IS TO NOTIFY THE
OWNER AND REMOVE AS REQUIRED BY LAW.
5. EXCEPT FOR ITEMS OR MATERIAL TO BE SALVAGED, RECYCLED, OR OTHERWISE
REUSED, REMOVE ALL WASTE MATERIALS FROM THE PROJECT SITE AND
LEGALLY DISPOSE OF THEM IN A LANDFILL OR INCINERATOR ACCEPTABLE TO
AUTHORITIES HAVING JURISDICTION.
6. EXISTING UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEM ARE TO BE
REMOVED, RELOCATED, OR ABANDONED IN CEILINGS TO BE DEMOLISHED.
7. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SYSTEMS
DEMOLITION.
8. CONTRACTOR IS TO NOTIFY ARCHITECT IMMEDIATELY UPON THE DISCOVERY OF
ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE DEMOLITION PROCESS.
9. ALL EXISTING CONSTRUCTION REMAINING IS TO BE PROTECTED DURING
DEMOLITION AND BUILD OUT. CONTRACTOR IS RESPONSIBLE FOR PROTECTING
AND/OR MOVING AND REINSTALLING ALL EXISTING FURNITURE, AS WELL AS
WALL MOUNTED ITEMS (HAND SANITIZER, TACK BOARDS, DISPLAY CASE, PAPER
SIGNS, ETC.) ASSOCIATED WITH THE WORK. PROTECT ROOM IDENTIFICATION
SIGNS IN PLACE.
10. EXISTING FIRE ALARM SYSTEM INCLUDING BUT NOT LIMITED TO STROBES,
AUDIO DEVICES, PULL STATIONS, AND ALL OTHER SYSTEM COMPONENTS MUST
REMAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION. DEVICES THAT
ARE IN THE WAY OF NEW WORK MUST BE SUPPORTED IN PLACE DURING THE
COURSE OF CONSTRUCTION AND REATTACHED TO SUBSTRATE UPON
COMPLETION OF WORK. CONTRACTOR MUST COORDINATE THE TIMING OF
REMOVAL OF LIFE SAFETY DEVICES.
ANDREW JOHN
Lic No. 15101
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
AD101
LEVEL 1 - DEMO - FLOOR
PLAN
Checker
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
1/16" = 1'-0"A600 AD101
2 LEVEL 1 - DEMO - FLOOR PLAN
KEYED DEMOLITION NOTES
GENERAL DEMOLITION NOTES
02 22 11 EXISTING BOTTLE FILLING STATION + DRINKING FOUNTAIN TO REMAIN. PROTECT
IN PLACE.
02 22 19 EXISTING TILE FLOOR TO REMAIN. DEEP CLEAN AND PROTECT IN PLACE.
02 22 20 EXISTING METAL HAND RAILING THROUGHOUT POOL AREA TO REMAIN. SCRAPE
OFF PAINT BUILD UP TO PROVIDE SMOOTH CLEAN SURFACE. PREP FOR NEW
WORK.
02 41 16 REMOVE EXISTING FIRE EXTINGUISHER. STORE DURING DEMOLITION AND
REINSTALL IN NEW WORK. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF PROJECT.
02 41 23 REMOVE EXISTING HOLLOW METAL DOOR, FRAME, AND HARDWARE, COMPLETE.
02 41 24 REMOVE EXISTING HOLLOW METAL FRAME AND HARDWARE, COMPLETE.
02 41 26 REMOVE EXISTING CARPET AND ADHESIVE, COMPLETE. PREPARE FOR NEW
CARPET INSTALLATION PER MANUFACTURERS REQUIREMENTS.
02 41 27 REMOVE EXISTING WALL BASE, THROUGHOUT. SCRAPE OFF ADHESIVE TO
PROVIDE SMOOTH CLEAN SURFACE. PREP FOR NEW WORK. ALL LOCATIONS THAT
WILL BE PAINTED, RECEIVE NEW VINYL WALL GRAPHICS OR FLOORING, WILL
RECEIVE NEW WALL BASE.
02 41 28 REMOVE EXISTING DRINK VENDING MACHINE. STORE DURING DEMOLITION AND
RE-INSTALL IN NEW WORK.
02 41 29 REMOVE EXISTING FURNITURE AND WALL MOUNTED ITEMS, COMPLETE. STORE
DURING CONSTRUCTION AND REINSTALL IN SAME PLACE.
02 41 30 REMOVE EXISTING DRINKING FOUNTAIN, PLUMBING TO REMAIN FOR NEW BOTTLE
FILLING STATION + DRINKING FOUNTAIN TO BE INSTALLED. REMOVE AND REPAIR
CMU AS NECESSARY.
HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT
IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT
FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT EXCEED 50%
OF THE VALUE OF THE BUILDING
ASBESTOS DISCLOSURE STATEMENT
AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE
AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO
DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN
APPENDIX TO THE PROJECT SPECIFICATION
LEAD MATERIALS DISCLOSURE STATEMENT
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS
HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS
REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT
IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL
SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE
EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE
RECYCLED TO THE EXTENT POSSIBLE.
N
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
E
F
D
C
B
G
H
A
OFFICE
OFFICE
CONF.
OFFICE
OFFICE
OFFICE
CONF.
OFFICE
211A
OFFICE
CORRIDOR
OFFICE
STAIR
209 STAIR
CLO.
218A
CLO.
217A
V E
S T
STAIR
V E
S T
IB
U
L E
STAIR
OPEN TO
BELOW
OPEN TO
BELOW
OFFICE
02 41 27 02 41 27
02 41 22
02 41 22
02 41 22 02 41 22
02 41 22
02 41 22 02 41 2713
AD102 A701
02 41 27
02 22 18
NOT IN
CONTRACT
NOT IN
CONTRACT
02 41 27
02 41 29
02 41 29
02 41 2902 41 29
02 41 29
1. WHERE IT IS CALLED OUT TO PATCH AND REPAIR AREAS, NEW CONSTRUCTION
IS TO MATCH ADJACENT CONSTRUCTION.
2. WHERE EXISTING DOORS AND WINDOWS ARE REQUIRED TO BE DEMOLISHED,
CAREFULLY SAW CUT FRAMING MEMBERS AND REMOVE AS REQUIRED.
3. WHERE PLUMBING OR ELECTRICAL FIXTURES ARE TO BE DEMOLISHED
CAREFULLY CAP ALL WATER LINES, CONDUIT, AND ALL WIRING BEFORE
REMOVAL.
4. IF HAZARDOUS MATERIAL IS SUSPECTED, CONTRACTOR IS TO NOTIFY THE
OWNER AND REMOVE AS REQUIRED BY LAW.
5. EXCEPT FOR ITEMS OR MATERIAL TO BE SALVAGED, RECYCLED, OR OTHERWISE
REUSED, REMOVE ALL WASTE MATERIALS FROM THE PROJECT SITE AND
LEGALLY DISPOSE OF THEM IN A LANDFILL OR INCINERATOR ACCEPTABLE TO
AUTHORITIES HAVING JURISDICTION.
6. EXISTING UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEM ARE TO BE
REMOVED, RELOCATED, OR ABANDONED IN CEILINGS TO BE DEMOLISHED.
7. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SYSTEMS
DEMOLITION.
8. CONTRACTOR IS TO NOTIFY ARCHITECT IMMEDIATELY UPON THE DISCOVERY OF
ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE DEMOLITION PROCESS.
9. ALL EXISTING CONSTRUCTION REMAINING IS TO BE PROTECTED DURING
DEMOLITION AND BUILD OUT. CONTRACTOR IS RESPONSIBLE FOR PROTECTING
AND/OR MOVING AND REINSTALLING ALL EXISTING FURNITURE, AS WELL AS
WALL MOUNTED ITEMS (HAND SANITIZER, TACK BOARDS, DISPLAY CASE, PAPER
SIGNS, ETC.) ASSOCIATED WITH THE WORK. PROTECT ROOM IDENTIFICATION
SIGNS IN PLACE.
10. EXISTING FIRE ALARM SYSTEM INCLUDING BUT NOT LIMITED TO STROBES,
AUDIO DEVICES, PULL STATIONS, AND ALL OTHER SYSTEM COMPONENTS MUST
REMAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION. DEVICES THAT
ARE IN THE WAY OF NEW WORK MUST BE SUPPORTED IN PLACE DURING THE
COURSE OF CONSTRUCTION AND REATTACHED TO SUBSTRATE UPON
COMPLETION OF WORK. CONTRACTOR MUST COORDINATE THE TIMING OF
REMOVAL OF LIFE SAFETY DEVICES.
ANDREW JOHN
Lic No. 15101
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
AD102
LEVEL 2 - DEMO - FLOOR
PLAN
Checker
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
1/16" = 1'-0"A600 AD102
1 LEVEL 2 - DEMO - FLOOR PLAN
HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT
IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT
FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT EXCEED 50%
OF THE VALUE OF THE BUILDING
ASBESTOS DISCLOSURE STATEMENT
AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE
AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO
DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN
APPENDIX TO THE PROJECT SPECIFICATION
LEAD MATERIALS DISCLOSURE STATEMENT
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS
HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS
REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT
IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL
SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE
EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE
RECYCLED TO THE EXTENT POSSIBLE.
KEYED DEMOLITION NOTES
GENERAL DEMOLITION NOTES
02 22 18 EXISTING VINYL WALL WRAP TO REMAIN. PROTECT IN PLACE.
02 41 22 REMOVE EXISTING WALL MOUNTED AUDIO, VISUAL, WI-FI, AND SOUND
EQUIPMENT, AND MOUNTING HARDWARE, COMPLETE, TYPICAL. STORE DURING
DEMOLITION. REINSTALL WALL-MOUNTED ITEMS IN LOCATION IDENTIFIED ON
DRAWINGS. REFERENCE NEW WORK DRAWINGS FOR EXACT LOCATIONS.
02 41 27 REMOVE EXISTING WALL BASE, THROUGHOUT. SCRAPE OFF ADHESIVE TO
PROVIDE SMOOTH CLEAN SURFACE. PREP FOR NEW WORK. ALL LOCATIONS THAT
WILL BE PAINTED, RECEIVE NEW VINYL WALL GRAPHICS OR FLOORING, WILL
RECEIVE NEW WALL BASE.
02 41 29 REMOVE EXISTING FURNITURE AND WALL MOUNTED ITEMS, COMPLETE. STORE
DURING CONSTRUCTION AND REINSTALL IN SAME PLACE.
N
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
02 41 11
02 41 10
02 41 11
02 41 10
02 41 11
02 41 10
02 41 10
02 41 11
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
02 41 11
02 41 11
02 41 10
02 41 11
02 41 10
02 41 10
02 41 11
OPEN TO
ABOVE
OPEN TO
ABOVE
OPEN TO
ABOVE
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
AD103 A106
AD103 A106
02 41 13
02 22 09
02 22 09
02 22 09
02 22 03
02 22 01
02 41 13
02 41 12
02 41 12
02 41 13
02 41 10
02 41 11
02 41 13
02 41 14
AD103 A106
AD103 A106
02 41 12 02 41 13
02 41 11 02 41 10 02 41 13
02 41 12 02 41 17
02 41 13
02 41 12
02 41 17
02 41 14
02 41 11
02 41 18
02 41 12
02 41 11
02 41 10
02 41 10
02 41 10
02 41 18
02 41 13
02 41 11
02 41 11
02 41 10
02 41 11
02 41 18
02 41 10
02 41 10
02 41 13
02 41 11
02 41 17
02 41 13
02 41 17
02 22 12
02 41 11
02 41 14
02 41 10
02 41 11
02 22 12
02 41 14
02 22 12
02 41 13
02 41 11
02 41 10
02 41 13
02 41 11
AD103 A107
02 41 13
02 41 11
02 41 18
EXISTING GWB CEILING TO BE
REMOVED
EXISTING 2' X 4' LAY-IN LIGHT
FIXTURE TO BE REMOVED
EXISTING ACOUSTICAL CEILING
GRID AND TILE TO BE REMOVED
EXISTING 1' X 4' LAY-IN LIGHT
FIXTURE TO BE REMOVED
EXISTING SURVEILLANCE
CAMERA TO BE REMOVED
EXISTING 2' X 2' LAY-IN LIGHT
FIXTURE TO BE REMOVED
EXISTING PENDANT LIGHT
FIXTURE TO BE REMOVED
EXISTING AND NEW GWB
CEILING
EXISTING EXPOSED, PAINTED
STRUCTURE
EXISTING 2' X 4' LAY-IN LIGHT
FIXTURE TO REMAIN
EXISTING AND NEW
ACOUSTICAL CEILING GRID AND
TILE
EXISTING 2' X 2' LAY-IN LIGHT
FIXTURE TO REMAIN
EXISTING SUPPLY DUCTS TO REMAIN
EXISTING RETURN DUCT TO REMAIN
EXISTING EXIT SIGN TO REMAIN
EXISTING WIFI EQUIPEMT TO REMAIN
EXISTING MOTION SENSORS TO
REMAIN
EXISTING EMERGENCY WALL LIGHT
TO REMAIN
EXISTING HORN STROBE TO REMAIN
EXISTING CASSETTE MINI-SPLIT TO
REMAIN
EXISTING PROJECTOR TO REMAIN
EXISTING PENDANT LIGHT FIXTURE
TO REMAIN
1. WHERE IT IS CALLED OUT TO PATCH AND REPAIR AREAS, NEW CONSTRUCTION
IS TO MATCH ADJACENT CONSTRUCTION.
2. WHERE EXISTING DOORS AND WINDOWS ARE REQUIRED TO BE DEMOLISHED,
CAREFULLY SAW CUT FRAMING MEMBERS AND REMOVE AS REQUIRED.
3. WHERE PLUMBING OR ELECTRICAL FIXTURES ARE TO BE DEMOLISHED
CAREFULLY CAP ALL WATER LINES, CONDUIT, AND ALL WIRING BEFORE
REMOVAL.
4. IF HAZARDOUS MATERIAL IS SUSPECTED, CONTRACTOR IS TO NOTIFY THE
OWNER AND REMOVE AS REQUIRED BY LAW.
5. EXCEPT FOR ITEMS OR MATERIAL TO BE SALVAGED, RECYCLED, OR OTHERWISE
REUSED, REMOVE ALL WASTE MATERIALS FROM THE PROJECT SITE AND
LEGALLY DISPOSE OF THEM IN A LANDFILL OR INCINERATOR ACCEPTABLE TO
AUTHORITIES HAVING JURISDICTION.
6. EXISTING UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEM ARE TO BE
REMOVED, RELOCATED, OR ABANDONED IN CEILINGS TO BE DEMOLISHED.
7. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SYSTEMS
DEMOLITION.
8. CONTRACTOR IS TO NOTIFY ARCHITECT IMMEDIATELY UPON THE DISCOVERY OF
ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE DEMOLITION PROCESS.
9. ALL EXISTING CONSTRUCTION REMAINING IS TO BE PROTECTED DURING
DEMOLITION AND BUILD OUT. CONTRACTOR IS RESPONSIBLE FOR PROTECTING
AND/OR MOVING AND REINSTALLING ALL EXISTING FURNITURE, AS WELL AS
WALL MOUNTED ITEMS (HAND SANITIZER, TACK BOARDS, DISPLAY CASE, PAPER
SIGNS, ETC.) ASSOCIATED WITH THE WORK. PROTECT ROOM IDENTIFICATION
SIGNS IN PLACE.
10. EXISTING FIRE ALARM SYSTEM INCLUDING BUT NOT LIMITED TO STROBES,
AUDIO DEVICES, PULL STATIONS, AND ALL OTHER SYSTEM COMPONENTS MUST
REMAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION. DEVICES THAT
ARE IN THE WAY OF NEW WORK MUST BE SUPPORTED IN PLACE DURING THE
COURSE OF CONSTRUCTION AND REATTACHED TO SUBSTRATE UPON
COMPLETION OF WORK. CONTRACTOR MUST COORDINATE THE TIMING OF
REMOVAL OF LIFE SAFETY DEVICES.
ANDREW JOHN
Lic No. 15101
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
AD103
LEVEL 1 - DEMO -
REFLECTED CEILING PLAN
Checker
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
1/16" = 1'-0"A600 AD103
1 LEVEL 1 - DEMO - REFLECTED CEILING PLAN
HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT
IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT
FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT EXCEED 50%
OF THE VALUE OF THE BUILDING
ASBESTOS DISCLOSURE STATEMENT
AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE
AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO
DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN
APPENDIX TO THE PROJECT SPECIFICATION
LEAD MATERIALS DISCLOSURE STATEMENT
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS
HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS
REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT
IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL
SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE
EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE
RECYCLED TO THE EXTENT POSSIBLE.
REFLECTED CEILING PLAN LEGEND - DEMOLITION
KEYED DEMOLITION NOTES
GENERAL DEMOLITION NOTES
02 22 01 EXISTING ACOUSTICAL CEILING TILE, GRID AND SUSPENSION SYSTEM TO REMAIN.
REPLACE ANY DISCOLORED, DAMAGED, BROKEN, OR MISSING TILES. PROTECT IN
PLACE.
02 22 03 EXISTING LIGHT FIXTURE TO REMAIN. PROTECT IN PLACE. REFERENCE
ELECTRICAL DRAWINGS.
02 22 09 EXISTING SURVEILLANCE EQUIPMENT TO REMAIN. PROTECT IN PLACE.
02 22 12 EXISTING GYPSUM CEILING TO REMAIN. PROTECT IN PLACE.
02 41 10 REMOVE EXISTING ACOUSTICAL CEILING TILES, GRID, AND SUSPENSION SYSTEM,
COMPLETE. PREP FOR NEW WORK.
02 41 11 REMOVE EXISTING INTERIOR LIGHT FIXTURE, HOUSING, AND MOUNTING
HARDWARE, COMPLETE, TYPICAL. REFERENCE ELECTRICAL DRAWINGS.
02 41 12 REMOVE EXISTING CEILING MOUNTED AUDIO, VISUAL, WI-FI, AND SOUND
EQUIPMENT, AND MOUNTING HARDWARE, COMPLETE, TYPICAL. STORE DURING
DEMOLITION. REINSTALL CEILING-MOUNTED ITEMS ALIGNED TO CEILING GRID.
REFERENCE NEW WORK DRAWINGS FOR EXACT LOCATIONS.
02 41 13 REMOVE EXISTING EMERGENCY EXIT SIGNS FROM CEILING GRID SCHEDULED TO
BE DEMOLISHED, COMPLETE, TYPICAL. CONTRACTOR IS RESPONSIBLE FOR
MAINTAINING CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF
PROJECT.
02 41 14 REMOVE EXISTING WALL-MOUNTED EMERGENCY LIGHT FIXTURE. STORE DURING
DEMOLITION AND REINSTALL IN NEW WORK. CONTRACTOR IS RESPONSIBLE FOR
MAINTAINING CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF
PROJECT.
02 41 17 REMOVE EXISTING FIRE HORN STROBES. STORE DURING DEMOLITION AND
REINSTALL IN NEW WORK. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF PROJECT.
02 41 18 REMOVE, CLEAN, AND REINSTALL EXISTING SUPPLY + RETURN GRILLES AND
EXHAUST FAN COVERS ALIGNED TO CEILING GRID. REFERENCE MECHANICAL
DRAWINGS.
N
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
02 41 10
02 41 11
02 41 10
02 41 11
02 41 10
02 22 02
02 41 10
02 41 11
02 41 10
02 41 11
02 41 10
02 41 12
02 41 31
02 41 10
02 41 11
02 41 13
02 41 14
02 22 02
02 41 18
02 41 11
02 22 01
02 22 02
02 41 12
02 41 18
02 41 11
02 22 01
02 41 13
02 41 17
02 41 11
02 41 31
02 41 11
02 41 10
02 41 10
02 41 11
02 41 10
02 41 11
02 22 02
02 22 15
02 22 15
02 22 15
02 22 16
02 22 16
02 22 17
02 22 17
02 41 31 02 41 31
02 41 31
02 22 02
02 22 0202 41 31
NOT IN
CONTRACT
NOT IN
CONTRACT
02 22 02
02 22 02
02 41 12
02 22 14
02 41 13
02 41 17
02 41 13
02 22 01
02 41 11
AD104 A107
02 41 12
EXISTING GWB CEILING TO BE
REMOVED
EXISTING 2' X 4' LAY-IN LIGHT
FIXTURE TO BE REMOVED
EXISTING ACOUSTICAL CEILING
GRID AND TILE TO BE REMOVED
EXISTING 1' X 4' LAY-IN LIGHT
FIXTURE TO BE REMOVED
EXISTING SURVEILLANCE
CAMERA TO BE REMOVED
EXISTING 2' X 2' LAY-IN LIGHT
FIXTURE TO BE REMOVED
EXISTING PENDANT LIGHT
FIXTURE TO BE REMOVED
EXISTING AND NEW GWB
CEILING
EXISTING EXPOSED, PAINTED
STRUCTURE
EXISTING 2' X 4' LAY-IN LIGHT
FIXTURE TO REMAIN
EXISTING AND NEW
ACOUSTICAL CEILING GRID AND
TILE
EXISTING 2' X 2' LAY-IN LIGHT
FIXTURE TO REMAIN
EXISTING SUPPLY DUCTS TO REMAIN
EXISTING RETURN DUCT TO REMAIN
EXISTING EXIT SIGN TO REMAIN
EXISTING WIFI EQUIPEMT TO REMAIN
EXISTING MOTION SENSORS TO
REMAIN
EXISTING EMERGENCY WALL LIGHT
TO REMAIN
EXISTING HORN STROBE TO REMAIN
EXISTING CASSETTE MINI-SPLIT TO
REMAIN
EXISTING PROJECTOR TO REMAIN
EXISTING PENDANT LIGHT FIXTURE
TO REMAIN
1. WHERE IT IS CALLED OUT TO PATCH AND REPAIR AREAS, NEW CONSTRUCTION
IS TO MATCH ADJACENT CONSTRUCTION.
2. WHERE EXISTING DOORS AND WINDOWS ARE REQUIRED TO BE DEMOLISHED,
CAREFULLY SAW CUT FRAMING MEMBERS AND REMOVE AS REQUIRED.
3. WHERE PLUMBING OR ELECTRICAL FIXTURES ARE TO BE DEMOLISHED
CAREFULLY CAP ALL WATER LINES, CONDUIT, AND ALL WIRING BEFORE
REMOVAL.
4. IF HAZARDOUS MATERIAL IS SUSPECTED, CONTRACTOR IS TO NOTIFY THE
OWNER AND REMOVE AS REQUIRED BY LAW.
5. EXCEPT FOR ITEMS OR MATERIAL TO BE SALVAGED, RECYCLED, OR OTHERWISE
REUSED, REMOVE ALL WASTE MATERIALS FROM THE PROJECT SITE AND
LEGALLY DISPOSE OF THEM IN A LANDFILL OR INCINERATOR ACCEPTABLE TO
AUTHORITIES HAVING JURISDICTION.
6. EXISTING UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEM ARE TO BE
REMOVED, RELOCATED, OR ABANDONED IN CEILINGS TO BE DEMOLISHED.
7. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SYSTEMS
DEMOLITION.
8. CONTRACTOR IS TO NOTIFY ARCHITECT IMMEDIATELY UPON THE DISCOVERY OF
ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE DEMOLITION PROCESS.
9. ALL EXISTING CONSTRUCTION REMAINING IS TO BE PROTECTED DURING
DEMOLITION AND BUILD OUT. CONTRACTOR IS RESPONSIBLE FOR PROTECTING
AND/OR MOVING AND REINSTALLING ALL EXISTING FURNITURE, AS WELL AS
WALL MOUNTED ITEMS (HAND SANITIZER, TACK BOARDS, DISPLAY CASE, PAPER
SIGNS, ETC.) ASSOCIATED WITH THE WORK. PROTECT ROOM IDENTIFICATION
SIGNS IN PLACE.
10. EXISTING FIRE ALARM SYSTEM INCLUDING BUT NOT LIMITED TO STROBES,
AUDIO DEVICES, PULL STATIONS, AND ALL OTHER SYSTEM COMPONENTS MUST
REMAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION. DEVICES THAT
ARE IN THE WAY OF NEW WORK MUST BE SUPPORTED IN PLACE DURING THE
COURSE OF CONSTRUCTION AND REATTACHED TO SUBSTRATE UPON
COMPLETION OF WORK. CONTRACTOR MUST COORDINATE THE TIMING OF
REMOVAL OF LIFE SAFETY DEVICES.
ANDREW JOHN
Lic No. 15101
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
AD104
LEVEL 2 - DEMO -
REFLECTED CEILING PLAN
Checker
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
1/16" = 1'-0"A600 AD104
1 LEVEL 2 - DEMO - REFLECTED CEILING PLAN
HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT
IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT
FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT EXCEED 50%
OF THE VALUE OF THE BUILDING
ASBESTOS DISCLOSURE STATEMENT
AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE
AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO
DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN
APPENDIX TO THE PROJECT SPECIFICATION
LEAD MATERIALS DISCLOSURE STATEMENT
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS
HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS
REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT
IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL
SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE
EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE
RECYCLED TO THE EXTENT POSSIBLE.
REFLECTED CEILING PLAN LEGEND - DEMOLITION
KEYED DEMOLITION NOTES
GENERAL DEMOLITION NOTES
02 22 01 EXISTING ACOUSTICAL CEILING TILE, GRID AND SUSPENSION SYSTEM TO REMAIN.
REPLACE ANY DISCOLORED, DAMAGED, BROKEN, OR MISSING TILES. PROTECT IN
PLACE.
02 22 02 EXISTING MECHANICAL EQUIPMENT TO REMAIN. CLEAN AND PROTECT IN PLACE,
TYPICAL. REFERENCE MECHANICAL DRAWINGS.
02 22 14 EXISTING WALL MOUNTED EMERGENCY LIGHT FIXTURE TO REMAIN. PROTECT IN
PLACE.
02 22 15 EXISTING MECHANICAL EQUIPMENT TO REMAIN. CLEAN AND PREPARE FOR NEW
FINISH TO BE APPLIED IN NEW WORK. PROTECT IN PLACE. REFERENCE
MECHANICAL DRAWINGS.
02 22 16 EXISTING LIGHTS TO REMAIN. ABANDON IN PLACE.
02 22 17 EXISTING SKYLIGHTS TO REMAIN. CLEAN AND PROTECT IN PLACE.
02 41 10 REMOVE EXISTING ACOUSTICAL CEILING TILES, GRID, AND SUSPENSION SYSTEM,
COMPLETE. PREP FOR NEW WORK.
02 41 11 REMOVE EXISTING INTERIOR LIGHT FIXTURE, HOUSING, AND MOUNTING
HARDWARE, COMPLETE, TYPICAL. REFERENCE ELECTRICAL DRAWINGS.
02 41 12 REMOVE EXISTING CEILING MOUNTED AUDIO, VISUAL, WI-FI, AND SOUND
EQUIPMENT, AND MOUNTING HARDWARE, COMPLETE, TYPICAL. STORE DURING
DEMOLITION. REINSTALL CEILING-MOUNTED ITEMS ALIGNED TO CEILING GRID.
REFERENCE NEW WORK DRAWINGS FOR EXACT LOCATIONS.
02 41 13 REMOVE EXISTING EMERGENCY EXIT SIGNS FROM CEILING GRID SCHEDULED TO
BE DEMOLISHED, COMPLETE, TYPICAL. CONTRACTOR IS RESPONSIBLE FOR
MAINTAINING CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF
PROJECT.
02 41 14 REMOVE EXISTING WALL-MOUNTED EMERGENCY LIGHT FIXTURE. STORE DURING
DEMOLITION AND REINSTALL IN NEW WORK. CONTRACTOR IS RESPONSIBLE FOR
MAINTAINING CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF
PROJECT.
02 41 17 REMOVE EXISTING FIRE HORN STROBES. STORE DURING DEMOLITION AND
REINSTALL IN NEW WORK. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF PROJECT.
02 41 18 REMOVE, CLEAN, AND REINSTALL EXISTING SUPPLY + RETURN GRILLES AND
EXHAUST FAN COVERS ALIGNED TO CEILING GRID. REFERENCE MECHANICAL
DRAWINGS.
02 41 31 REMOVE EXISTING INTERIOR LIGHT FIXTURE, HOUSING, AND MOUNTING
HARDWARE, TYPICAL. EXISTING CIRCUIT TO REMAIN FOR NEW WORK.
REFERENCE ELECTRICAL DRAWINGS.
N
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
UPUP
UP
UP
UP
UP
UPUP
UP
UP
E
F
D
C
B
G
H
A
GYMNASIUM
SWIMMING
POOL
CORRIDOR
STAIR
STAIR
STAIR
STAIR
CORRIDOR
CORRIDOR
VEST.
190A
CORRIDOR
168 VESTIBULE
170A
CLO.
VEST.
100B
VEST.
100A
OFFICE
WOMEN'S RR
MEN'S RR
MECH.
VEST.
170D
ROTC
176E
ROTC
ROTC
176D
ROTC
176C
ROTC
176B
ROTC
176A
VEST.
150A
CORRIDOR
MECH.
VEST.
150B
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
NOT IN
CONTRACT
OFFICE
110A
OFFICE
CONF.
OFFICE
OFFICE
CORRIDOR
VESTIBULE
OFFICE
113A
OFFICE
113B
COMPUTER
LAB
C L
O
C
CLO.
110C
CLO.
110D
A101 A701
A101 A702
A101 A702
A101 A702
A101 A702
A7051
A704
1 A703 1
A706 1
09 72 01
A101 A600
A101 A600
09 91 01
09 91 01 09 91 01
09 91 03
09 91 09
09 91 10
09 91 10
09 91 09
09 91 03
09 91 03
09 91 01
09 91 01
09 91 01
08 11 02
08 11 02
09 91 01
09 91 01
09 91 01
09 91 01
09 91 01
09 91 01
08 11 02
09 91 01
11 20 04
09 91 01
09 91 01
09 91 01
09 91 01
09 72 02
08 11 01
09 72 08
09 91 01
09 91 03
09 91 01
22 47 01
OFFICE
110B
09 68 01
09 68 01
09 65 02
09 65 02
09 72 08
09 72 08
100A
100B
100C
100D
100E
100F
100G
100H
116A
1. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE
BUILDING CODES, ORDINANCES AND LAWS.
2. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM
THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
3. DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF STUD, CENTERLINE OF
OPENINGS, AND CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED.
DIMENSIONS FOR EXISTING CONSTRUCTION IS TO FINISH FACE OF WALL UNLESS
OTHERWISE NOTED. REFLECTED CEILING PLAN DIMENSIONS ARE TO FINISH
FACE OF WALL.
4. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF
ANY DISCREPANCIES. CONTRACTOR IS TO NOTIFY THE ARCHITECT IMMEDIATELY
UPON DISCOVERY OF ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE
WORK.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF OTHER TRADES
AND WORK BETWEEN THE TRADES TO ENSURE A FULL AND COMPLETE JOB.
6. ALL CHANGES IN WORK COMPLETED WITHOUT APPROVAL FROM THE OWNER
SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR WHO SHALL INCUR
ALL COST INVOLVED.
7. ALL MATERIALS SHALL BE INSTALLED PER MANUFACTURERS WRITTEN
INSTRUCTIONS UNLESS OTHERWISE NOTED (U.O.N.).
8. LIKE OR SIMILAR CONDITIONS NOT SPECIFICALLY NOTED SHALL BE
CONSTRUCTED IN A MANNER CONSISTENT W/ LIKE OR SIMILAR WORK/ DETAILS.
9. NEW PARTITIONS AND MASONRY WALLS SHALL MATCH THICKNESS AND
MATERIALITY OF EXISTING. ALL NEW MASONRY SHALL TOOTH-INTO EXISTING.
10. ALL LOCATIONS WHERE DEMOLITION WORK DAMAGES ADJACENT EXISTING
PAINTED FINISH SURFACE, CONTRACTOR IS TO REPAIR, CLEAN, PRIME, AND
PAINT. MATCH ADJACENT FINISH.
11. UPON DISCOVERY OF ANY PENETRATIONS TO FIRE BARRIERS, CONTRACTOR TO
REFER TO UNIT PRICES SPECIFICATION.
12. GRAPHICS PACKAGE IS A WORK IN PROGRESS. CONTRACTOR TO COORDINATE
VINYL WALL GRAPHICS WITH NSU GRAPHICS DEPARTMENT.
ANDREW JOHN
Lic No. 15101
McKINLEY
O
W E
LA
HT
M N O M
C O
I
F V
A I
N I
R G
ER
A
HC TI
C T
DATE:
CHECKED BY:
SHEET STATUS:
KEY PLAN:
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
CONSULTANT:
1/16" = 1'-0"
20 30
1/8" = 1'-0"
108642 18161412
1/4" = 1'-0"
54321 9876
3/8" = 1'-0"
21 64 53 7
1/2" = 1'-0"
21 43 5
3/4" = 1'-0"
1 32
1" = 1'-0"
1 2 3
3/16" = 1'-0"
42 8631 75 9
1-1/2" = 1'-0"
3" = 1'-0"
GRAPHIC
SCALE
VIA PROJ #:
viadesignarchitects.com
319 E Plume Street Norfolk, VA 23510
757 627 1489
SHEET TITLE:
SHEET NUMBER:
PERMIT SET
STATE PROJ #:
2024.03.05
20009-07
A101
LEVEL 1 - NEW WORK -
FLOOR PLAN
Checker
G
IL
L H
E A
L T
H
P E
C
E
IL
IN
G
L
IG
H T
IN
G
I N
T E
R
IO
R F
IN
IS
H E
S U
P G
R A
D E
S
N o rf o lk
S ta te U n iv e rs it y
P a rk
A v e
N o rf o lk
V
A
2024.03.05
213-2324-009
1/16" = 1'-0"A600 A101
1 LEVEL 1 - NEW WORK - FLOOR PLAN
GENERAL NEW WORK NOTES
08 11 01 NEW DOOR, FRAME + HARDWARE, FIRE RATED. PERMANENT CENTER MULLION.
08 11 02 NEW DOORS, FRAMES, AND HARDWARE. ONE MULLION NEEDS TO BE
REMOVABLE. FIRE RATED DOORS + FRAMES. PANIC EGRESS HARDWARE THAT
CAN BE LOCKED TO PREVENT ACCESS FROM EXTERIOR BUT PERMITS EGRESS
FROM INTERIOR.
09 65 02 NEW WALL BASE.
09 68 01 NEW TILE CARPETING
09 72 01 NEW VINYL GRAPHIC WALL WRAP: NORFOLK MAP
09 72 02 NEW VINYL GRAPHIC WALL WRAP: NSU TIMELINE. REFERENCE RENDERING A
09 72 08 NEW VINYL GRAPHIC DOOR WRAP: GREEN AND GOLD SLASH. REFERENCE
GRAPHICS PACKAGE.
09 91 01 CLEAN, PRIME, AND PAINT EXISTING DOOR AND DOOR FRAME IN NSU GREEN.
09 91 03 CLEAN, PRIME, AND PAINT FULL LENGTH OF EXISTING AND NEW CMU WALL IN
CORRIDOR. MATCH EXISTING FINISH.
09 91 09 CLEAN, PRIME, AND PAINT EXISTING POOL BLEACHER HANDRAILS, AND BENCH
SUPPORT BRACKETS BLACK.
09 91 10 CLEAN, PRIME, AND PAINT EXISTING LOW WALL IN NSU GREEN, AND A 4" STRIPE
BELOW TILE WALL CAP IN NSU YELLOW. PROVIDE CLEAN CRISP CONSISTENT LINE
WHERE COLORS MEET.
11 20 04 RE-INSTALL EXISTING DRINK VENDING MACHINE
22 47 01 NEW DRINKING FOUNTAIN AND BOTTLE FILLING STATION. NEW RECEPTACLE
REQUIRED, SEE ELECTRICAL DRAWINGS.
KEYED NEW WORK NOTES
HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT
IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT
FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT EXCEED 50%
OF THE VALUE OF THE BUILDING
ASBESTOS DISCLOSURE STATEMENT
AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE
AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO
DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN
APPENDIX TO THE PROJECT SPECIFICATION
LEAD MATERIALS DISCLOSURE STATEMENT
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS
HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS
REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT
IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL
SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE
EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE
RECYCLED TO THE EXTENT POSSIBLE.
N
R E
V
IS
IO
N
S
D
A T
E D
E S
C R
IP
T
E
F
D
C
B
G
H
A
STAIR
OFFICE
OFFICE
CONF.
OFFICE
OFFICE
OFFICE
CONF.
OFFICE
211A
OFFICE
STAIR
CORRIDOR
CLO.
218A
CLO.
217A
V E
S T
STAIR
V E
S T
IB
U
L E
STAIR
OFFICE
OPEN TO
BELOW
OPEN TO
BELOW
A102 A701
A7051
A706 1
Sim
A101 A600
Sim
A101 A600
09 29 0609 29 05
09 29 04 09 29 04
A703 1
A7041
NOT IN
CONTRACT
NOT IN
CONTRACT
A501
A501
A501
A501
27 40 02
27 40 02
A501
OFFICE
CONF. RR
211B
09 91 16
1. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE
BUILDING CODES, ORDINANCES AND LAWS.
2. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM
THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
3. DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF STUD, CENTERLINE OF
OPENINGS, AND CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED.
DIMENSIONS FOR EXISTING CONSTRUCTION IS TO FINISH FACE OF WALL UNLESS
OTHERWISE NOTED. REFLECTED CEILING PLAN DIMENSIONS ARE TO FINISH
FACE OF WALL.
4. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF
ANY DISCREPANCIES. CONTRACTOR IS TO NOTIFY THE ARCHITECT IMMEDIATELY
UPON DISCOVERY OF ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE
WORK.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF OTHER TRADES
AND WORK BETWEEN THE TRADES TO ENSURE A FULL AND COMPLETE JOB.
6. ALL CHANGES IN WORK COMPLETED WITHOUT APPROVAL FROM THE OWNER
SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR WHO SHALL INCUR
ALL COST INVOLVED.
7. ALL MATERIALS SHALL BE INSTALLED PER MANUFACTURERS WRITTEN
INSTRUCTIONS UNLESS OTHERWISE NOTED (U.O.N.).
8. LIKE OR SIMILAR CONDITIONS NOT SPECIFICALLY NOTED SHALL BE
CONSTRUCTED IN A MANNER CONSISTENT W/ LIKE OR SIMILAR WORK/ DETAILS.
9. NEW PARTITIONS AND MASONRY WALLS SHALL MATCH THICKNESS AND
MATERIALITY OF EXISTING. ALL NEW MASONRY SHALL TOOTH-INTO EXISTING.
10. ALL LOCATIONS WHERE DEMOLITION WORK DAMAGES ADJACENT EXISTING
PAINTED FINISH SURFACE, CONTRACTOR IS TO REPAIR, CLEAN, PRIME, AND
PAINT. MATCH ADJACENT FINISH.
11. UPON DISCOVERY OF ANY PENETRATIONS TO FIRE BARRIERS, CONTRACTOR TO
REFER TO UNIT PRICES SPECIFICATION.
12. GRAPHICS PACKAGE IS A WORK IN PROGRESS. CONTRACTOR TO COORDINATE
VINYL WALL GRAPHICS WITH NSU GRAPHICS DEPARTMENT.
ANDREW JOHN
Lic No. 15101
McKINLEY
O
W E
LA
HT
M N O M
C…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .