213-2324-009 Gill Health + PE - Ceiling & Lighting Upgrades - Drawings.pdf

PDF 20 MB Posted

Attached to
Gill Health + PE – Ceiling, Lighting, & Interior Finishes Upgrades
Solicitation number
62843
Issued by
Norfolk City, Virginia

About this file

This document appears to be a set of drawings related to a state and local contract opportunity in Virginia for the Gill Health + PE Building. The project will involve upgrading the existing lighting and lighting controls with new LED lighting, refreshing the interior painting, installing new branding graphics, a new acoustical ceiling, and other interior finishes. The project is located in Norfolk City. The document provides an overview of the scope of work and requirements, but does not include details on pricing, set asides, incumbents, funding sources, or other salient contract information.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOT IN

CONTRACTNOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

BRICK

ELEVATION

BRICK - PLAN

CMU - PLAN

CONCRETE

GROUT

GYPSUM

WALLBOARD

STEEL

INSUL - BATT

1t

DOOR TYPE

WINDOW TYPE

BUILDING/WALL/DETAIL SECTION #

SHEET # WHERE SECTION IS DRAWN

FLOOR LEVEL / ELEVATION

A101

Ref

1R e f

1 R e f

Ref

BUILDING ELEVATION TAG

SHEET # WHERE SECTION IS DRAWN

KEY NOTE

S1 WALL TYPE

ROOM TAG

ROOM #

ROOM SQUARE FOOTAGE

ALIGN

ENLARGED PLAN/DETAIL LOCATION

WITH SHEET TAKEN AND SHEET SHOWN

SIM

A102 A103

A101

SIM

PLAN NUMBER AND SHEET

EXISTING DOOR

TO REMAIN

A101

INTERIOR ELEVATION TAG

SHEET # WHERE ELEVATION IS DRAWN

1 Ref

R e f

1 Ref

R e f

SIM

A102A108

Room name

150 SF

Name Elevation

EXISTING PARTITION

TO BE DEMOLISHED

EXISTING PARTITION

TO REMAIN

NEW PARTITION

EXISTING DOOR TO

BE DEMOLISHED

NEW DOOR

OPEN TO

BELOW

OPEN TO

BELOW

NOT IN

CONTRACT

NOT IN

CONTRACT

VIRGINIA UNIFORM STATEWIDE BUILDING CODE 2018

VIRGINIA UNIFORM STATEWIDE EXISTING BUILDING CODE 2018

CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL 2023

VIRGINIA ENERGY CONSERVATION CODE COMPLIANCE STATEMENT

4. IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC), THE

BUILDING SHALL COMPLY WITH VECC SECTIONS C402 THROUGH C405 AND C408.

APPLICABLE CODES + STANDARDS

HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT

IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS

EXEMPT FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT

EXCEED 50% OF THE VALUE OF THE BUILDING

ASBESTOS DISCLOSURE STATEMENT

AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN

THE AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED

TO DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED

AS AN APPENDIX TO THE PROJECT SPECIFICATION

LEAD MATERIALS DISCLOSURE STATEMENT

AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING

COMPONENTS HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT

SPECIFICATIONS. THIS REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND

MAY NOT BE ALL INCLUSIVE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY

WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS

THEY PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED

BUILDING COMPONENTS SHALL BE RECYCLED TO THE EXTENT POSSIBLE.

GILL HEALTH + PE BUILDING CURRENTLY SERVES AS A HEALTH AND PHYSICAL

EDUCATION FACILITY HOUSING A GYMNASIUM, SWIMMING POOL, LOCKER

ROOMS, RESTROOMS, CLASSROOMS, AND OFFICES. THE GILL HEALTH + PE

BUILDING IS APPROXIMATELY 77,300 SF, WAS CONSTRUCTED IN 1961 AND IS

PRIMARILY A ONE STORY BUILDING WITH A PARTIAL SECOND FLOOR AROUND

THE GYMNASIUM PORTION OF THE BUILDING. THE BUILDING HAS LOAD BEARING

STEEL COLUMNS THAT SUPPORT THE UPPER FLOOR AND ROOF. THE ROOF IS

CONSTRUCTED OF METAL DECK SUPPORTED BY STEEL BEAMS AND OPEN WEB

STEEL JOISTS. THE ROOF OVER THE GYM IS A GABLE ROOF. EXTERIOR WALLS

CONSIST OF CONCRETE MASONRY WITH BRICK VENEER AND PRECAST

CONCRETE PANELS.

THIS PROJECT WILL UPGRADE THE EXISTING LIGHTING, LIGHTING CONTROLS,

CEILING + FLOOR + WALL FINISHES, AND GRAPHIC BRANDING. BUILDING WILL

REMAIN OCCUPIED BY OWNER DURING CONSTRUCTION.

PROJECT INFORMATION AND DESCRIPTION OF WORK

ANDREW JOHN

Lic No. 15101

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

T101

TITLE SHEET

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

GILL HEALTH & PE - CEILING, LIGHTING &

INTERIOR FINISHES UPGRADES

700 Park Ave, Norfolk, VA 23504

Norfolk State University

KEY PLANS

VICINITY MAP

LOCATION MAP

SHEET INDEX

ARCHITECT:

VIA DESIGN ARCHITECTS, PC

319 E PLUME STREET

NORFOLK, VA 23510

MECH., ELEC., PLUMB., ENGINEER:

COASTAL ENGINEERING, PLLC

2406 PRINCESS ANNE ROAD, #2

VIRGINIA BEACH, VA 23456

PROJECT TEAM

PROJECT IDENTIFICATION

STATE PROJECT NUMBER: 213-2324-009

VIA DESIGN PROJECT NUMBER: 20009-07

1/64" = 1'-0"A600 T101

1 LEVEL 1 - KEY PLAN

MATERIAL LEGEND ABBREVIATIONS

AFF

ACT

ARCH

CJ

CT

CONC

CONT

CMU

DEMO

DIA

DIM

DWG

EWC

EQ

FEC

GWB

ETR

ARCHITECTURAL SYMBOLS

AREA OF WORK

1/64" = 1'-0"A600 T101

2 LEVEL 2 - KEY PLAN

MFR

MO

MECH

MIN

NIC

NTS

OC

REF

RO

SIM

SPEC

STRUCT

TYP

UON

VIF

VWC

ABOVE FINISH FLOOR

ACOUSTICAL CEILING TILE

ARCHITECTURAL

CONTROL JOINT

CERAMIC TILE

CONCRETE

CONTINUOUS

CONCRETE MASONRY UNIT

DEMOLITION

DIAMETER

DIMENSION

DRAWING

ELECTRICAL WATER COOLER

EQUAL

FIRE EXTINGUISHER CABINET

GYPSUM WALL BOARD

EXISTING TO REMAIN

MANUFACTURER

MASONRY OPENING

MECHANICAL

MINIMUM

NOT IN CONTRACT

NOT TO SCALE

ON CENTER

REFERENCE

ROUGH OPENING

SIMILAR

SPECIFICATION

STRUCTURAL

TYPICAL

UNLESS OTHERWISE NOTED

VERIFY IN FIELD

VINYL WALL COVERING

ARCHITECTURAL SERIES

AD101 LEVEL 1 - DEMO - FLOOR PLAN

AD102 LEVEL 2 - DEMO - FLOOR PLAN

AD103 LEVEL 1 - DEMO - REFLECTED CEILING PLAN

AD104 LEVEL 2 - DEMO - REFLECTED CEILING PLAN

MECHANICAL SERIES

ELECTRICAL SERIES

TITLE SERIES

T101 TITLE SHEET

T102 SHORT FORM SPECIFICATIONS

T103 SHORT FORM SPECIFICATIONS

T104 3D RENDERINGS

T105 GRAPHICS PACKAGE

LIFE SAFETY SERIES

LS101 LIFE SAFETY PLANS + CODE ANALYSIS

PLUMBING SERIES

A101 LEVEL 1 - NEW WORK - FLOOR PLAN

A102 LEVEL 2 - NEW WORK - FLOOR PLAN

A103 LEVEL 1 - NEW WORK - REFLECTED CEILING PLAN

A104 LEVEL 2 - NEW WORK - REFLECTED CEILING PLAN

A105 ROOF - NEW WORK - ROOF PLAN

A106 DEMO + NEW WORK - ENLARGED REFLECTED CEILING PLANS

A107 DEMO - ENLARGED REFLECTED CEILING PLAN

A108 NEW WORK - ENLARGED REFLECTED CEILING PLAN

A501 TYPICAL DETAILS

A502 RESTROOM AND ACCESSIBILITY DETAILS

A600 ENLARGED STAIR ELEVATIONS

A701 ENLARGED PLANS + INTERIOR ELEVATIONS

A702 ENLARGED PLANS + INTERIOR ELEVATIONS

A703 ENLARGED PLANS + INTERIOR ELEVATIONS

A704 ENLARGED PLANS + INTERIOR ELEVATIONS

A705 ENLARGED PLANS + INTERIOR ELEVATIONS

A706 ENLARGED PLANS + INTERIOR ELEVATIONS

A800 DOOR + FINISH TYPES, SCHEDULE, + DETAILS

P001 PLANS-DEMO,LEGEND, ABBREVIATIONS, NOTES, AND SCHEDULE

P401 LARGE-SCALE VIEWS, ABBREVIATIONS AND LEGEND

P701 SPECIFICATIONS

M102 LEVEL 1 FLOOR PLAN DEMO WORK AND NOTES

M102 LEVEL 2 FLOOR PLAN DEMO WORK

M201 LEVEL 1 FLOOR PLAN NEW WORK

M202 LEVEL 2 FLOOR PLAN NEW WORK

M701 MECHANICAL SPECIFICATIONS

E001 LEGEND, ABBREVIATIONS, NOTES, LIGHTING FIXTURE SCHEDULE

E101 LEVEL 1 FLOOR PLAN DEMO WORK - LIGHTING & MISC.

E102 LEVEL 2 FLOOR PLAN DEMO WORK - LIGHTING

E201 LEVEL 1 FLOOR PLAN NEW WORK - LIGHTING & MISC.

E203 LEVEL 2 FLOOR PLAN NEW WORK - LIGHTING & MISC.

E501 ELECTRICAL DETAILS

E601 PANEL SCHEDULES

E602 LIGHTING CONTROLS RISER #1

E603 LIGHTING CONTROLS RISER #2

E604 LIGHTING CONTROLS RISER #3

E605 LIGHTING CONTROLS AND WIRING DIAGRAM

E606 LIGHTING CONTROLS

E702 ELECTRICAL SPECIFICATIONS

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

IO

N

UPON DISCOVERY OF PENETRATED FIRE BARRIERS, CONTRACTOR TO REFER TO UNIT PRICES SPECIFICATION.

PENETRATIONS SMALLER THAN 1" ARE TO BE PATCHED WITH GROUT.

PENETRATIONS UP TO 4" ARE TO BE REPAIRED WITH FIRE FOAM.

PENETRATIONS UP TO 24" X 24", LOOSE OR MISSING BLOCK, ARE TO BE REPAIRED WITH NEW BLOCK.

ABOVE CEILING CMU REPAIR NOTES

ANDREW JOHN

Lic No. 15101

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

T102

SHORT FORM

SPECIFICATIONS

Checker

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

IO

N

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

T103

SHORT FORM

SPECIFICATIONS

Checker

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

T104

3D RENDERINGS

Checker

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

R E

N D

E R

IN

G

B R

E N

D E

R

IN

G A

R E

N D

E R

IN

G

D R

E N

D E

R

IN

G C

R E

N D

E R

IN

G

F R

E N

D E

R

IN

G E

R E

N D

E R

IN

G

G

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

T105

GRAPHICS PACKAGE

Checker

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

NSU TIMELINE

SPARTAN HEAD @ FOOTBALL LOCKERS

NORFOLK MAP

SPARTAN STRONGSPARTAN HEAD @ GYMNSU STATISTICS

GREEN + GOLD SLASHDOOR WRAP: WOMEN

DOOR WRAP: MEN

NSU TIMELINE

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

UP

UP

GYMNASIUM

SWIMMING

POOL

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

MECH

MECH.

OFFICE

116B

PUMP

MECH.

MECH.

OFFICE

OFFICE

OFFICE

STORAGE

GOLF

SIMULATOR

M E

C H

ROTC

176E

ROTC

R O

T C

D

ROTC

176C

ROTC

176B

ROTC

176A

CLO.

STORAGE

STORAGE

STORAGE

CLO.

OFFICE

WEIGHT

ROOM

COMPUTER

LAB

OFFICE

110A

OFFICE

CONF.

OFFICE

O F

F

IC

E

O F

F

IC

E

A

O F

F

IC

E

B

VESTIBULE

MEN'S

LOCKER

STAIR

STAIR

STAIR

STAIR

CLO.

VEST

VEST.

170D

VEST.

150A

CLO.

CLO.

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CLO.

109B

CLO.

109A

CORRIDOR

168 VESTIBULE

170A

WOMEN'S RR

MEN'S RR

MECH.

CORRIDOR

FLEX

LOCKER

FLEX

RESTROOM

121A

FLEX

RESTROOM

119A

FLEX

LOCKER

WOMEN'S

LOCKER

LOCKER

VESTIBULE

LOCKER

SHOWER

COACHES'

SHOWER

COACHES'

LOCKER

VESTIBULE

S T

O R

A G

E

R E

S T

R O

O M

M E

N 'S

R R

W O

M E

N 'S

R R

VEST.

150BVEST.

190A

OFFICE

110B

JANITORS

CLO.

MECH

MECH.

VEST.

100A

VEST.

100B

OFFICE

OFFICE

CONF.

OFFICE

OFFICE

OFFICE

CONF.

OFFICE

211A

OFFICE

CORRIDOR

DANCE

STUDIO

OFFICE

STAIR

STAIR

VEST

STAIR

V E

S T

IB

U

L E

7 STAIR

OPEN TO

BELOW

OPEN TO

BELOW

OPEN TO

BELOW

OFFICE

GIRLS

LOCKER

ROOM

1 HOUR FIRE BARRIER

HORIZONTAL FIRE SEPARATION

ABOVE FINISH CEILING

WORK AREA SEPARATION LINE

ANDREW JOHN

Lic No. 15101

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

LS101

LIFE SAFETY PLANS + CODE

ANALYSIS

Checker

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

3/64" = 1'-0"A600 LS101

1 LEVEL 1 - LIFE SAFETY PLAN

3/64" = 1'-0"A600 LS101

2 LEVEL 2 - LIFE SAFETY PLAN

1/4" = 1'-0"

LIFE SAFETY LEGEND

CODE SUMMARY

RELEVANT CODES AND STANDARDS

VIRGINIA CONSTRUCTION CODE – 2018 (REFERENCED AS VCC)

VIRGINIA EXISTING BUILDING CODE – 2018 (REFERENCED AS VEBC)

THE EXISTING BUILDING:

• IS UNSPRINKLERED

• CONTAINS A FIRE ALARM SYSTEM

• CONTAINS SMOKE DETECTION - SMOKE DETECTION IS ALSO INCLUDED IN THE

NEW MECHANICAL SYSTEM

VIRGINIA CONSTRUCTION CODE - 2018

CHAPTER 3 - USE AND OCCUPANCY CLASSIFICATION

ASSEMBLY GROUP A-4 - INDOOR SWIMMING POOLS WITH SPECTATOR SEATING

ASSEMBLY GROUP A-4 - GYMNASIUMS WITH SPECTATOR SEATING

GYMNASIUMS WITH SPECTATOR SEATING ARE NOT SPECIFICALLY IDENTIFIED IN THE

VCC, BUT ARE MOST CLOSELY ALIGNED WITH GROUP A-4, INCLUDING "ASSEMBLY

USES INTENDED FOR VIEWING OF INDOOR SPORTING EVENTS AND ACTIVITIES WITH

SPECTATOR SEATING"

BUSINESS GROUP B - BUSINESS OFFICE AREAS AND EDUCATIONAL CLASSROOMS

FOR STUDENTS ABOVE THE 12TH GRADE

CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS

508.4 SEPARATED OCCUPANCIES

PER VCC TABLE 508.4 THE BUILDING SHALL BE CONSIDERED SEPARATED

OCCUPANCIES

NOTE: THE DESIGN TEAM HAS SPENT CONSIDERABLE TIME IN THE BUILDING

REVIEWING EXISTING DOOR RATINGS AND CONTINUITY OF PARTITIONS. ALL KNOWN

RATED PARTITIONS HAVE BEEN IDENTIFIED ON THE LIFE SAFETY PLANS. AREAS

THAT ARE NOT INDICATED AS RATED ARE A RESULT OF EITHER AN OPENING THAT IS

NOT PROTECTED BY A RATED DOOR, OR WALL CONSTRUCTION THAT DOES NOT

CONTINUE TO THE UNDERSIDE OF CONSTRUCTION ABOVE.

CHAPTER 6 - TYPES OF CONSTRUCTION

THE EXISTING BUILDING IS CLASSIFIED AS TYPE IIB

EXISTING BUILDING ELEMENTS ARE OF NONCOMBUSTIBLE MATERIALS, INCLUDING

THE PRIMARY STRUCTURAL FRAME, EXTERIOR BEARING WALLS, NONBEARING WALLS

ON THE INTERIOR AND EXTERIOR, NONBEARING WALLS AND PARTITIONS, FLOOR

CONSTRUCTION, AND ROOF CONSTRUCTION AND ASSOCIATED SECONDARY

MEMBERS.

EXISTING BUILDING ELEMENTS ARE NONCOMBUSTIBLE, AND ARE UNPROTECTED

THE NEW BUILDING ELEMENTS WILL UTILIZE SIMILAR MATERIALS

CHAPTER 8 - FINISHES

803.1.2 - INTERIOR WALL AND CEILING FINISH MATERIALS ARE SPECIFIED IN

ACCORDANCE WITH ASTM E84 OR UL 723

CLASS A = FLAME SPREAD INDEX 0-25; SMOKE-DEVELOPED INDEX 0-450

CLASS B = FLAME SPREAD INDEX 26-75; SMOKE-DEVELOPED INDEX 0-450

CLASS C = FLAME SPREAD INDEX 76-200; SMOKE-DEVELOPED INDEX 0-450

803.13 - INTERIOR FINISH REQUIREMENTS BASED ON OCCUPANCY

INTERIOR EXIT STAIRS CORRIDORS ROOMS/ENCLOSED SPACES

A-4 A A C B A B C

CHAPTER 3 – GENERAL PROVISIONS AND SPECIAL DETAILED REQUIREMENTS

301 - GENERAL

301.2 OCCUPANCY AND USE

OCCUPANCY AND USE IS DETERMINED PER CHAPTER 3 OF THE VCC

THERE ARE NO CHANGES TO OCCUPANCY AND USE AS A RESULT OF THIS PROJECT

302.1 - NEW AND REPLACEMENT MATERIALS

THE PROJECT WILL UTILIZE LIKE MATERIALS

302.3 SMOKE ALARMS

ALL SMOKE ALARMS ARE EXISTING TO REMAIN AND SHALL REMAIN OPERATIONAL AT

ALL TIMES DURING CONSTRUCTION.

CODE SUMMARY – VIRGINIA EXISTING BUILDING CODE – 2018 CONTINUED

CHAPTER 4 - ACCESSIBILITY

404 - ALTERATIONS

404.2 - ALTERATIONS

ACCESSIBILITY REQUIREMENTS SHALL COMPLY WITH THE CPSM, SECTION 4.2

ACCESSIBILITY STANDARDS FOR STATE-OWNED FACILITIES. THE PRESCRIBED

ACCESSIBILITY STANDARDS ARE THE DEPARTMENT OF JUSTICE’S 2010 ADA

STANDARDS FOR ACCESSIBLE DESIGN, DATED SEPTEMBER 15, 2010

THERE ARE NO ALTERATIONS TO BUILDING ELEMENTS THAT WILL AFFECT

ACCESSIBILITY AS A RESULT OF THIS PROJECT

CHAPTER 6 - ALTERATIONS

601.2 - LEVELS OF ALTERATIONS

601.2.1 LEVEL 1

LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE

COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES USING

NEW MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME

PURPOSE, OR THE REMOVAL WITHOUT REPLACEMENT OF MATERIALS, ELEMENTS,

EQUIPMENT, OR FIXTURES. LEVEL 1 ALTERATIONS SHALL COMPLY WITH THE

APPLICABLE PROVISIONS OF SECTION 602.

601.2.2 LEVEL 2

LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF

SECTIONS 602 AND 603 AND SHALL INCLUDE THE FOLLOWING:

1. THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW.

2. THE ADDITION OR ELIMINATION OF ANY WALL, FLOOR, OR CEILING ASSEMBLY.

3. THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM.

4. THE INSTALLATION OF ANY ADDITION, EQUIPMENT, MATERIALS, ELEMENTS

OR FIXTURES.

DOORS AND FINISH FLOORS WILL BE ELIMINATED AND ADDED AS A PART OF THIS

PROJECT. NO WINDOWS OR WALLS WILL BE ADDED OR ELIMINATED. ACT CEILING

ASSEMBLIES WILL BE REMOVED AND REPLACED IN SOME LOCATIONS AS PART OF

THE PROJECT. MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS WILL BE

MODIFIED AS PART OF THE PROJECT.

DUE TO PROPOSED ALTERATIONS TO THE BUILDING, THE WORK IS CLASSIFIED AS A

LEVEL 2 ALTERATION

601.4 ENERGY CONSERVATION

EXCEPT AS MODIFIED BY THIS SECTION, ALTERATIONS TO AN EXISTING

BUILDING, BUILDING SYSTEM OR STRUCTURE SHALL CONFORM TO THE APPLICABLE

PROVISIONS OF THE VIRGINIA ENERGY CONSERVATION CODE AS THEY RELATE TO

NEW CONSTRUCTION WITHOUT REQUIRING THE UNALTERED PORTIONS OF THE

EXISTING BUILDING, BUILDING SYSTEM, OR STRUCTURE TO COMPLY WITH THE

VECC.

602 - ALTERATION LEVEL 1

602.2 - CONFORMANCE

ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE

FOLLOWING:

1. LEVEL OF FIRE PROTECTION THAT IS EXISTING

2. LEVEL OF PROTECTION THAT IS EXISTING FOR THE MEANS OF EGRESS

FIRE PROTECTION AND MEANS OF EGRESS SHALL BE MAINTAINED

602.3 BUILDING ELEMENTS AND MATERIALS

602.3.1 INTERIOR FINISHES AND TRIM

ALL NEWLY INSTALLED INTERIOR FINISH AND TRIM MATERIALS AND WALL, FLOOR

AND CEILING FINISHES SHALL COMPLY WITH CHAPTER 8 OF THE VCC.

CHAPTER 7 - CHANGE OF OCCUPANCY

NO CHANGES TO THE OCCUPANCY CLASSIFICATION OF THE BUILDING WILL OCCUR

AS PART OF THIS WORK

CHAPTER 12 – CONSTRUCTION SAFEGUARDS

1201.4 MANNER OF REMOVAL

WASTE MATERIALS SHALL BE REMOVED IN A MANNER WHICH PREVENTS INJURY OR

DAMAGE TO PERSONS, ADJOINING PROPERTIES, AND PUBLIC RIGHTS-OF-WAY.

1201.5 FIRE SAFETY DURING CONSTRUCTION

FIRE SAFETY DURING CONSTRUCTION SHALL COMPLY WITH THE APPLICABLE

REQUIREMENTS OF THE VCC

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

UPUP

UP

UP

UP

UP

UP

E

F

D

C

B

G

H

A

STAIR

VEST.

150A

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

GYMNASIUM

CORRIDOR

STAIR

STAIR

STAIR

STAIR

CORRIDOR

CORRIDOR

VEST.

190A

CORRIDOR

168 VESTIBULE

170A

VEST.

100B

VEST.

100A

OFFICE

WOMEN'S RR

MEN'S RR

MECH.

VEST.

170D

CORRIDOR

MECH.

VEST.

150B

SWIMMING

POOL

ROTC

176E

ROTC

ROTC

176D

ROTC

176C

ROTC

176B

ROTC

176A

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

OFFICE

110A

CLO.

110C

CLO.

110D

OFFICE

C L

O

C

OFFICE

113A

OFFICE

113B

VESTIBULE

CORRIDOR

OFFICE

OFFICE

CONF.

COMPUTER

LAB

02 41 27

AD101 A701

02 41 28

02 41 28

02 41 23

02 41 16

02 22 11

02 41 24

02 41 27

02 41 27

02 41 26

02 22 19

02 22 19

02 22 20 02 22 20

02 22 20

02 41 23

OFFICE

110B

02 41 27

02 41 23

02 41 23

02 41 23

02 41 27

02 41 30

02 41 27

02 41 27

02 41 27

02 41 27

02 41 29

02 22 11

02 41 2902 41 29

02 41 29

02 41 29

02 41 2902 41 2902 41 29

02 41 27

02 41 26

02 41 2902 41 29

1. WHERE IT IS CALLED OUT TO PATCH AND REPAIR AREAS, NEW CONSTRUCTION

IS TO MATCH ADJACENT CONSTRUCTION.

2. WHERE EXISTING DOORS AND WINDOWS ARE REQUIRED TO BE DEMOLISHED,

CAREFULLY SAW CUT FRAMING MEMBERS AND REMOVE AS REQUIRED.

3. WHERE PLUMBING OR ELECTRICAL FIXTURES ARE TO BE DEMOLISHED

CAREFULLY CAP ALL WATER LINES, CONDUIT, AND ALL WIRING BEFORE

REMOVAL.

4. IF HAZARDOUS MATERIAL IS SUSPECTED, CONTRACTOR IS TO NOTIFY THE

OWNER AND REMOVE AS REQUIRED BY LAW.

5. EXCEPT FOR ITEMS OR MATERIAL TO BE SALVAGED, RECYCLED, OR OTHERWISE

REUSED, REMOVE ALL WASTE MATERIALS FROM THE PROJECT SITE AND

LEGALLY DISPOSE OF THEM IN A LANDFILL OR INCINERATOR ACCEPTABLE TO

AUTHORITIES HAVING JURISDICTION.

6. EXISTING UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEM ARE TO BE

REMOVED, RELOCATED, OR ABANDONED IN CEILINGS TO BE DEMOLISHED.

7. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SYSTEMS

DEMOLITION.

8. CONTRACTOR IS TO NOTIFY ARCHITECT IMMEDIATELY UPON THE DISCOVERY OF

ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE DEMOLITION PROCESS.

9. ALL EXISTING CONSTRUCTION REMAINING IS TO BE PROTECTED DURING

DEMOLITION AND BUILD OUT. CONTRACTOR IS RESPONSIBLE FOR PROTECTING

AND/OR MOVING AND REINSTALLING ALL EXISTING FURNITURE, AS WELL AS

WALL MOUNTED ITEMS (HAND SANITIZER, TACK BOARDS, DISPLAY CASE, PAPER

SIGNS, ETC.) ASSOCIATED WITH THE WORK. PROTECT ROOM IDENTIFICATION

SIGNS IN PLACE.

10. EXISTING FIRE ALARM SYSTEM INCLUDING BUT NOT LIMITED TO STROBES,

AUDIO DEVICES, PULL STATIONS, AND ALL OTHER SYSTEM COMPONENTS MUST

REMAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION. DEVICES THAT

ARE IN THE WAY OF NEW WORK MUST BE SUPPORTED IN PLACE DURING THE

COURSE OF CONSTRUCTION AND REATTACHED TO SUBSTRATE UPON

COMPLETION OF WORK. CONTRACTOR MUST COORDINATE THE TIMING OF

REMOVAL OF LIFE SAFETY DEVICES.

ANDREW JOHN

Lic No. 15101

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

AD101

LEVEL 1 - DEMO - FLOOR

PLAN

Checker

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

1/16" = 1'-0"A600 AD101

2 LEVEL 1 - DEMO - FLOOR PLAN

KEYED DEMOLITION NOTES

GENERAL DEMOLITION NOTES

02 22 11 EXISTING BOTTLE FILLING STATION + DRINKING FOUNTAIN TO REMAIN. PROTECT

IN PLACE.

02 22 19 EXISTING TILE FLOOR TO REMAIN. DEEP CLEAN AND PROTECT IN PLACE.

02 22 20 EXISTING METAL HAND RAILING THROUGHOUT POOL AREA TO REMAIN. SCRAPE

OFF PAINT BUILD UP TO PROVIDE SMOOTH CLEAN SURFACE. PREP FOR NEW

WORK.

02 41 16 REMOVE EXISTING FIRE EXTINGUISHER. STORE DURING DEMOLITION AND

REINSTALL IN NEW WORK. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING

CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF PROJECT.

02 41 23 REMOVE EXISTING HOLLOW METAL DOOR, FRAME, AND HARDWARE, COMPLETE.

02 41 24 REMOVE EXISTING HOLLOW METAL FRAME AND HARDWARE, COMPLETE.

02 41 26 REMOVE EXISTING CARPET AND ADHESIVE, COMPLETE. PREPARE FOR NEW

CARPET INSTALLATION PER MANUFACTURERS REQUIREMENTS.

02 41 27 REMOVE EXISTING WALL BASE, THROUGHOUT. SCRAPE OFF ADHESIVE TO

PROVIDE SMOOTH CLEAN SURFACE. PREP FOR NEW WORK. ALL LOCATIONS THAT

WILL BE PAINTED, RECEIVE NEW VINYL WALL GRAPHICS OR FLOORING, WILL

RECEIVE NEW WALL BASE.

02 41 28 REMOVE EXISTING DRINK VENDING MACHINE. STORE DURING DEMOLITION AND

RE-INSTALL IN NEW WORK.

02 41 29 REMOVE EXISTING FURNITURE AND WALL MOUNTED ITEMS, COMPLETE. STORE

DURING CONSTRUCTION AND REINSTALL IN SAME PLACE.

02 41 30 REMOVE EXISTING DRINKING FOUNTAIN, PLUMBING TO REMAIN FOR NEW BOTTLE

FILLING STATION + DRINKING FOUNTAIN TO BE INSTALLED. REMOVE AND REPAIR

CMU AS NECESSARY.

HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT

IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT

FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT EXCEED 50%

OF THE VALUE OF THE BUILDING

ASBESTOS DISCLOSURE STATEMENT

AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE

AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO

DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN

APPENDIX TO THE PROJECT SPECIFICATION

LEAD MATERIALS DISCLOSURE STATEMENT

AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS

HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS

REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT

IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL

SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE

EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE

RECYCLED TO THE EXTENT POSSIBLE.

N

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

E

F

D

C

B

G

H

A

OFFICE

OFFICE

CONF.

OFFICE

OFFICE

OFFICE

CONF.

OFFICE

211A

OFFICE

CORRIDOR

OFFICE

STAIR

209 STAIR

CLO.

218A

CLO.

217A

V E

S T

STAIR

V E

S T

IB

U

L E

STAIR

OPEN TO

BELOW

OPEN TO

BELOW

OFFICE

02 41 27 02 41 27

02 41 22

02 41 22

02 41 22 02 41 22

02 41 22

02 41 22 02 41 2713

AD102 A701

02 41 27

02 22 18

NOT IN

CONTRACT

NOT IN

CONTRACT

02 41 27

02 41 29

02 41 29

02 41 2902 41 29

02 41 29

1. WHERE IT IS CALLED OUT TO PATCH AND REPAIR AREAS, NEW CONSTRUCTION

IS TO MATCH ADJACENT CONSTRUCTION.

2. WHERE EXISTING DOORS AND WINDOWS ARE REQUIRED TO BE DEMOLISHED,

CAREFULLY SAW CUT FRAMING MEMBERS AND REMOVE AS REQUIRED.

3. WHERE PLUMBING OR ELECTRICAL FIXTURES ARE TO BE DEMOLISHED

CAREFULLY CAP ALL WATER LINES, CONDUIT, AND ALL WIRING BEFORE

REMOVAL.

4. IF HAZARDOUS MATERIAL IS SUSPECTED, CONTRACTOR IS TO NOTIFY THE

OWNER AND REMOVE AS REQUIRED BY LAW.

5. EXCEPT FOR ITEMS OR MATERIAL TO BE SALVAGED, RECYCLED, OR OTHERWISE

REUSED, REMOVE ALL WASTE MATERIALS FROM THE PROJECT SITE AND

LEGALLY DISPOSE OF THEM IN A LANDFILL OR INCINERATOR ACCEPTABLE TO

AUTHORITIES HAVING JURISDICTION.

6. EXISTING UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEM ARE TO BE

REMOVED, RELOCATED, OR ABANDONED IN CEILINGS TO BE DEMOLISHED.

7. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SYSTEMS

DEMOLITION.

8. CONTRACTOR IS TO NOTIFY ARCHITECT IMMEDIATELY UPON THE DISCOVERY OF

ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE DEMOLITION PROCESS.

9. ALL EXISTING CONSTRUCTION REMAINING IS TO BE PROTECTED DURING

DEMOLITION AND BUILD OUT. CONTRACTOR IS RESPONSIBLE FOR PROTECTING

AND/OR MOVING AND REINSTALLING ALL EXISTING FURNITURE, AS WELL AS

WALL MOUNTED ITEMS (HAND SANITIZER, TACK BOARDS, DISPLAY CASE, PAPER

SIGNS, ETC.) ASSOCIATED WITH THE WORK. PROTECT ROOM IDENTIFICATION

SIGNS IN PLACE.

10. EXISTING FIRE ALARM SYSTEM INCLUDING BUT NOT LIMITED TO STROBES,

AUDIO DEVICES, PULL STATIONS, AND ALL OTHER SYSTEM COMPONENTS MUST

REMAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION. DEVICES THAT

ARE IN THE WAY OF NEW WORK MUST BE SUPPORTED IN PLACE DURING THE

COURSE OF CONSTRUCTION AND REATTACHED TO SUBSTRATE UPON

COMPLETION OF WORK. CONTRACTOR MUST COORDINATE THE TIMING OF

REMOVAL OF LIFE SAFETY DEVICES.

ANDREW JOHN

Lic No. 15101

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

AD102

LEVEL 2 - DEMO - FLOOR

PLAN

Checker

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

1/16" = 1'-0"A600 AD102

1 LEVEL 2 - DEMO - FLOOR PLAN

HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT

IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT

FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT EXCEED 50%

OF THE VALUE OF THE BUILDING

ASBESTOS DISCLOSURE STATEMENT

AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE

AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO

DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN

APPENDIX TO THE PROJECT SPECIFICATION

LEAD MATERIALS DISCLOSURE STATEMENT

AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS

HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS

REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT

IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL

SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE

EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE

RECYCLED TO THE EXTENT POSSIBLE.

KEYED DEMOLITION NOTES

GENERAL DEMOLITION NOTES

02 22 18 EXISTING VINYL WALL WRAP TO REMAIN. PROTECT IN PLACE.

02 41 22 REMOVE EXISTING WALL MOUNTED AUDIO, VISUAL, WI-FI, AND SOUND

EQUIPMENT, AND MOUNTING HARDWARE, COMPLETE, TYPICAL. STORE DURING

DEMOLITION. REINSTALL WALL-MOUNTED ITEMS IN LOCATION IDENTIFIED ON

DRAWINGS. REFERENCE NEW WORK DRAWINGS FOR EXACT LOCATIONS.

02 41 27 REMOVE EXISTING WALL BASE, THROUGHOUT. SCRAPE OFF ADHESIVE TO

PROVIDE SMOOTH CLEAN SURFACE. PREP FOR NEW WORK. ALL LOCATIONS THAT

WILL BE PAINTED, RECEIVE NEW VINYL WALL GRAPHICS OR FLOORING, WILL

RECEIVE NEW WALL BASE.

02 41 29 REMOVE EXISTING FURNITURE AND WALL MOUNTED ITEMS, COMPLETE. STORE

DURING CONSTRUCTION AND REINSTALL IN SAME PLACE.

N

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

02 41 11

02 41 10

02 41 11

02 41 10

02 41 11

02 41 10

02 41 10

02 41 11

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

02 41 11

02 41 11

02 41 10

02 41 11

02 41 10

02 41 10

02 41 11

OPEN TO

ABOVE

OPEN TO

ABOVE

OPEN TO

ABOVE

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

AD103 A106

AD103 A106

02 41 13

02 22 09

02 22 09

02 22 09

02 22 03

02 22 01

02 41 13

02 41 12

02 41 12

02 41 13

02 41 10

02 41 11

02 41 13

02 41 14

AD103 A106

AD103 A106

02 41 12 02 41 13

02 41 11 02 41 10 02 41 13

02 41 12 02 41 17

02 41 13

02 41 12

02 41 17

02 41 14

02 41 11

02 41 18

02 41 12

02 41 11

02 41 10

02 41 10

02 41 10

02 41 18

02 41 13

02 41 11

02 41 11

02 41 10

02 41 11

02 41 18

02 41 10

02 41 10

02 41 13

02 41 11

02 41 17

02 41 13

02 41 17

02 22 12

02 41 11

02 41 14

02 41 10

02 41 11

02 22 12

02 41 14

02 22 12

02 41 13

02 41 11

02 41 10

02 41 13

02 41 11

AD103 A107

02 41 13

02 41 11

02 41 18

EXISTING GWB CEILING TO BE

REMOVED

EXISTING 2' X 4' LAY-IN LIGHT

FIXTURE TO BE REMOVED

EXISTING ACOUSTICAL CEILING

GRID AND TILE TO BE REMOVED

EXISTING 1' X 4' LAY-IN LIGHT

FIXTURE TO BE REMOVED

EXISTING SURVEILLANCE

CAMERA TO BE REMOVED

EXISTING 2' X 2' LAY-IN LIGHT

FIXTURE TO BE REMOVED

EXISTING PENDANT LIGHT

FIXTURE TO BE REMOVED

EXISTING AND NEW GWB

CEILING

EXISTING EXPOSED, PAINTED

STRUCTURE

EXISTING 2' X 4' LAY-IN LIGHT

FIXTURE TO REMAIN

EXISTING AND NEW

ACOUSTICAL CEILING GRID AND

TILE

EXISTING 2' X 2' LAY-IN LIGHT

FIXTURE TO REMAIN

EXISTING SUPPLY DUCTS TO REMAIN

EXISTING RETURN DUCT TO REMAIN

EXISTING EXIT SIGN TO REMAIN

EXISTING WIFI EQUIPEMT TO REMAIN

EXISTING MOTION SENSORS TO

REMAIN

EXISTING EMERGENCY WALL LIGHT

TO REMAIN

EXISTING HORN STROBE TO REMAIN

EXISTING CASSETTE MINI-SPLIT TO

REMAIN

EXISTING PROJECTOR TO REMAIN

EXISTING PENDANT LIGHT FIXTURE

TO REMAIN

1. WHERE IT IS CALLED OUT TO PATCH AND REPAIR AREAS, NEW CONSTRUCTION

IS TO MATCH ADJACENT CONSTRUCTION.

2. WHERE EXISTING DOORS AND WINDOWS ARE REQUIRED TO BE DEMOLISHED,

CAREFULLY SAW CUT FRAMING MEMBERS AND REMOVE AS REQUIRED.

3. WHERE PLUMBING OR ELECTRICAL FIXTURES ARE TO BE DEMOLISHED

CAREFULLY CAP ALL WATER LINES, CONDUIT, AND ALL WIRING BEFORE

REMOVAL.

4. IF HAZARDOUS MATERIAL IS SUSPECTED, CONTRACTOR IS TO NOTIFY THE

OWNER AND REMOVE AS REQUIRED BY LAW.

5. EXCEPT FOR ITEMS OR MATERIAL TO BE SALVAGED, RECYCLED, OR OTHERWISE

REUSED, REMOVE ALL WASTE MATERIALS FROM THE PROJECT SITE AND

LEGALLY DISPOSE OF THEM IN A LANDFILL OR INCINERATOR ACCEPTABLE TO

AUTHORITIES HAVING JURISDICTION.

6. EXISTING UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEM ARE TO BE

REMOVED, RELOCATED, OR ABANDONED IN CEILINGS TO BE DEMOLISHED.

7. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SYSTEMS

DEMOLITION.

8. CONTRACTOR IS TO NOTIFY ARCHITECT IMMEDIATELY UPON THE DISCOVERY OF

ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE DEMOLITION PROCESS.

9. ALL EXISTING CONSTRUCTION REMAINING IS TO BE PROTECTED DURING

DEMOLITION AND BUILD OUT. CONTRACTOR IS RESPONSIBLE FOR PROTECTING

AND/OR MOVING AND REINSTALLING ALL EXISTING FURNITURE, AS WELL AS

WALL MOUNTED ITEMS (HAND SANITIZER, TACK BOARDS, DISPLAY CASE, PAPER

SIGNS, ETC.) ASSOCIATED WITH THE WORK. PROTECT ROOM IDENTIFICATION

SIGNS IN PLACE.

10. EXISTING FIRE ALARM SYSTEM INCLUDING BUT NOT LIMITED TO STROBES,

AUDIO DEVICES, PULL STATIONS, AND ALL OTHER SYSTEM COMPONENTS MUST

REMAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION. DEVICES THAT

ARE IN THE WAY OF NEW WORK MUST BE SUPPORTED IN PLACE DURING THE

COURSE OF CONSTRUCTION AND REATTACHED TO SUBSTRATE UPON

COMPLETION OF WORK. CONTRACTOR MUST COORDINATE THE TIMING OF

REMOVAL OF LIFE SAFETY DEVICES.

ANDREW JOHN

Lic No. 15101

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

AD103

LEVEL 1 - DEMO -

REFLECTED CEILING PLAN

Checker

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

1/16" = 1'-0"A600 AD103

1 LEVEL 1 - DEMO - REFLECTED CEILING PLAN

HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT

IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT

FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT EXCEED 50%

OF THE VALUE OF THE BUILDING

ASBESTOS DISCLOSURE STATEMENT

AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE

AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO

DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN

APPENDIX TO THE PROJECT SPECIFICATION

LEAD MATERIALS DISCLOSURE STATEMENT

AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS

HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS

REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT

IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL

SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE

EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE

RECYCLED TO THE EXTENT POSSIBLE.

REFLECTED CEILING PLAN LEGEND - DEMOLITION

KEYED DEMOLITION NOTES

GENERAL DEMOLITION NOTES

02 22 01 EXISTING ACOUSTICAL CEILING TILE, GRID AND SUSPENSION SYSTEM TO REMAIN.

REPLACE ANY DISCOLORED, DAMAGED, BROKEN, OR MISSING TILES. PROTECT IN

PLACE.

02 22 03 EXISTING LIGHT FIXTURE TO REMAIN. PROTECT IN PLACE. REFERENCE

ELECTRICAL DRAWINGS.

02 22 09 EXISTING SURVEILLANCE EQUIPMENT TO REMAIN. PROTECT IN PLACE.

02 22 12 EXISTING GYPSUM CEILING TO REMAIN. PROTECT IN PLACE.

02 41 10 REMOVE EXISTING ACOUSTICAL CEILING TILES, GRID, AND SUSPENSION SYSTEM,

COMPLETE. PREP FOR NEW WORK.

02 41 11 REMOVE EXISTING INTERIOR LIGHT FIXTURE, HOUSING, AND MOUNTING

HARDWARE, COMPLETE, TYPICAL. REFERENCE ELECTRICAL DRAWINGS.

02 41 12 REMOVE EXISTING CEILING MOUNTED AUDIO, VISUAL, WI-FI, AND SOUND

EQUIPMENT, AND MOUNTING HARDWARE, COMPLETE, TYPICAL. STORE DURING

DEMOLITION. REINSTALL CEILING-MOUNTED ITEMS ALIGNED TO CEILING GRID.

REFERENCE NEW WORK DRAWINGS FOR EXACT LOCATIONS.

02 41 13 REMOVE EXISTING EMERGENCY EXIT SIGNS FROM CEILING GRID SCHEDULED TO

BE DEMOLISHED, COMPLETE, TYPICAL. CONTRACTOR IS RESPONSIBLE FOR

MAINTAINING CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF

PROJECT.

02 41 14 REMOVE EXISTING WALL-MOUNTED EMERGENCY LIGHT FIXTURE. STORE DURING

DEMOLITION AND REINSTALL IN NEW WORK. CONTRACTOR IS RESPONSIBLE FOR

MAINTAINING CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF

PROJECT.

02 41 17 REMOVE EXISTING FIRE HORN STROBES. STORE DURING DEMOLITION AND

REINSTALL IN NEW WORK. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING

CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF PROJECT.

02 41 18 REMOVE, CLEAN, AND REINSTALL EXISTING SUPPLY + RETURN GRILLES AND

EXHAUST FAN COVERS ALIGNED TO CEILING GRID. REFERENCE MECHANICAL

DRAWINGS.

N

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

02 41 10

02 41 11

02 41 10

02 41 11

02 41 10

02 22 02

02 41 10

02 41 11

02 41 10

02 41 11

02 41 10

02 41 12

02 41 31

02 41 10

02 41 11

02 41 13

02 41 14

02 22 02

02 41 18

02 41 11

02 22 01

02 22 02

02 41 12

02 41 18

02 41 11

02 22 01

02 41 13

02 41 17

02 41 11

02 41 31

02 41 11

02 41 10

02 41 10

02 41 11

02 41 10

02 41 11

02 22 02

02 22 15

02 22 15

02 22 15

02 22 16

02 22 16

02 22 17

02 22 17

02 41 31 02 41 31

02 41 31

02 22 02

02 22 0202 41 31

NOT IN

CONTRACT

NOT IN

CONTRACT

02 22 02

02 22 02

02 41 12

02 22 14

02 41 13

02 41 17

02 41 13

02 22 01

02 41 11

AD104 A107

02 41 12

EXISTING GWB CEILING TO BE

REMOVED

EXISTING 2' X 4' LAY-IN LIGHT

FIXTURE TO BE REMOVED

EXISTING ACOUSTICAL CEILING

GRID AND TILE TO BE REMOVED

EXISTING 1' X 4' LAY-IN LIGHT

FIXTURE TO BE REMOVED

EXISTING SURVEILLANCE

CAMERA TO BE REMOVED

EXISTING 2' X 2' LAY-IN LIGHT

FIXTURE TO BE REMOVED

EXISTING PENDANT LIGHT

FIXTURE TO BE REMOVED

EXISTING AND NEW GWB

CEILING

EXISTING EXPOSED, PAINTED

STRUCTURE

EXISTING 2' X 4' LAY-IN LIGHT

FIXTURE TO REMAIN

EXISTING AND NEW

ACOUSTICAL CEILING GRID AND

TILE

EXISTING 2' X 2' LAY-IN LIGHT

FIXTURE TO REMAIN

EXISTING SUPPLY DUCTS TO REMAIN

EXISTING RETURN DUCT TO REMAIN

EXISTING EXIT SIGN TO REMAIN

EXISTING WIFI EQUIPEMT TO REMAIN

EXISTING MOTION SENSORS TO

REMAIN

EXISTING EMERGENCY WALL LIGHT

TO REMAIN

EXISTING HORN STROBE TO REMAIN

EXISTING CASSETTE MINI-SPLIT TO

REMAIN

EXISTING PROJECTOR TO REMAIN

EXISTING PENDANT LIGHT FIXTURE

TO REMAIN

1. WHERE IT IS CALLED OUT TO PATCH AND REPAIR AREAS, NEW CONSTRUCTION

IS TO MATCH ADJACENT CONSTRUCTION.

2. WHERE EXISTING DOORS AND WINDOWS ARE REQUIRED TO BE DEMOLISHED,

CAREFULLY SAW CUT FRAMING MEMBERS AND REMOVE AS REQUIRED.

3. WHERE PLUMBING OR ELECTRICAL FIXTURES ARE TO BE DEMOLISHED

CAREFULLY CAP ALL WATER LINES, CONDUIT, AND ALL WIRING BEFORE

REMOVAL.

4. IF HAZARDOUS MATERIAL IS SUSPECTED, CONTRACTOR IS TO NOTIFY THE

OWNER AND REMOVE AS REQUIRED BY LAW.

5. EXCEPT FOR ITEMS OR MATERIAL TO BE SALVAGED, RECYCLED, OR OTHERWISE

REUSED, REMOVE ALL WASTE MATERIALS FROM THE PROJECT SITE AND

LEGALLY DISPOSE OF THEM IN A LANDFILL OR INCINERATOR ACCEPTABLE TO

AUTHORITIES HAVING JURISDICTION.

6. EXISTING UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEM ARE TO BE

REMOVED, RELOCATED, OR ABANDONED IN CEILINGS TO BE DEMOLISHED.

7. REFER TO MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SYSTEMS

DEMOLITION.

8. CONTRACTOR IS TO NOTIFY ARCHITECT IMMEDIATELY UPON THE DISCOVERY OF

ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE DEMOLITION PROCESS.

9. ALL EXISTING CONSTRUCTION REMAINING IS TO BE PROTECTED DURING

DEMOLITION AND BUILD OUT. CONTRACTOR IS RESPONSIBLE FOR PROTECTING

AND/OR MOVING AND REINSTALLING ALL EXISTING FURNITURE, AS WELL AS

WALL MOUNTED ITEMS (HAND SANITIZER, TACK BOARDS, DISPLAY CASE, PAPER

SIGNS, ETC.) ASSOCIATED WITH THE WORK. PROTECT ROOM IDENTIFICATION

SIGNS IN PLACE.

10. EXISTING FIRE ALARM SYSTEM INCLUDING BUT NOT LIMITED TO STROBES,

AUDIO DEVICES, PULL STATIONS, AND ALL OTHER SYSTEM COMPONENTS MUST

REMAIN OPERATIONAL AT ALL TIMES DURING CONSTRUCTION. DEVICES THAT

ARE IN THE WAY OF NEW WORK MUST BE SUPPORTED IN PLACE DURING THE

COURSE OF CONSTRUCTION AND REATTACHED TO SUBSTRATE UPON

COMPLETION OF WORK. CONTRACTOR MUST COORDINATE THE TIMING OF

REMOVAL OF LIFE SAFETY DEVICES.

ANDREW JOHN

Lic No. 15101

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

AD104

LEVEL 2 - DEMO -

REFLECTED CEILING PLAN

Checker

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

1/16" = 1'-0"A600 AD104

1 LEVEL 2 - DEMO - REFLECTED CEILING PLAN

HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT

IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT

FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT EXCEED 50%

OF THE VALUE OF THE BUILDING

ASBESTOS DISCLOSURE STATEMENT

AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE

AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO

DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN

APPENDIX TO THE PROJECT SPECIFICATION

LEAD MATERIALS DISCLOSURE STATEMENT

AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS

HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS

REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT

IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL

SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE

EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE

RECYCLED TO THE EXTENT POSSIBLE.

REFLECTED CEILING PLAN LEGEND - DEMOLITION

KEYED DEMOLITION NOTES

GENERAL DEMOLITION NOTES

02 22 01 EXISTING ACOUSTICAL CEILING TILE, GRID AND SUSPENSION SYSTEM TO REMAIN.

REPLACE ANY DISCOLORED, DAMAGED, BROKEN, OR MISSING TILES. PROTECT IN

PLACE.

02 22 02 EXISTING MECHANICAL EQUIPMENT TO REMAIN. CLEAN AND PROTECT IN PLACE,

TYPICAL. REFERENCE MECHANICAL DRAWINGS.

02 22 14 EXISTING WALL MOUNTED EMERGENCY LIGHT FIXTURE TO REMAIN. PROTECT IN

PLACE.

02 22 15 EXISTING MECHANICAL EQUIPMENT TO REMAIN. CLEAN AND PREPARE FOR NEW

FINISH TO BE APPLIED IN NEW WORK. PROTECT IN PLACE. REFERENCE

MECHANICAL DRAWINGS.

02 22 16 EXISTING LIGHTS TO REMAIN. ABANDON IN PLACE.

02 22 17 EXISTING SKYLIGHTS TO REMAIN. CLEAN AND PROTECT IN PLACE.

02 41 10 REMOVE EXISTING ACOUSTICAL CEILING TILES, GRID, AND SUSPENSION SYSTEM,

COMPLETE. PREP FOR NEW WORK.

02 41 11 REMOVE EXISTING INTERIOR LIGHT FIXTURE, HOUSING, AND MOUNTING

HARDWARE, COMPLETE, TYPICAL. REFERENCE ELECTRICAL DRAWINGS.

02 41 12 REMOVE EXISTING CEILING MOUNTED AUDIO, VISUAL, WI-FI, AND SOUND

EQUIPMENT, AND MOUNTING HARDWARE, COMPLETE, TYPICAL. STORE DURING

DEMOLITION. REINSTALL CEILING-MOUNTED ITEMS ALIGNED TO CEILING GRID.

REFERENCE NEW WORK DRAWINGS FOR EXACT LOCATIONS.

02 41 13 REMOVE EXISTING EMERGENCY EXIT SIGNS FROM CEILING GRID SCHEDULED TO

BE DEMOLISHED, COMPLETE, TYPICAL. CONTRACTOR IS RESPONSIBLE FOR

MAINTAINING CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF

PROJECT.

02 41 14 REMOVE EXISTING WALL-MOUNTED EMERGENCY LIGHT FIXTURE. STORE DURING

DEMOLITION AND REINSTALL IN NEW WORK. CONTRACTOR IS RESPONSIBLE FOR

MAINTAINING CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF

PROJECT.

02 41 17 REMOVE EXISTING FIRE HORN STROBES. STORE DURING DEMOLITION AND

REINSTALL IN NEW WORK. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING

CONTINUITY OF ALL EMERGENCY SYSTEMS DURING DURATION OF PROJECT.

02 41 18 REMOVE, CLEAN, AND REINSTALL EXISTING SUPPLY + RETURN GRILLES AND

EXHAUST FAN COVERS ALIGNED TO CEILING GRID. REFERENCE MECHANICAL

DRAWINGS.

02 41 31 REMOVE EXISTING INTERIOR LIGHT FIXTURE, HOUSING, AND MOUNTING

HARDWARE, TYPICAL. EXISTING CIRCUIT TO REMAIN FOR NEW WORK.

REFERENCE ELECTRICAL DRAWINGS.

N

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

UPUP

UP

UP

UP

UP

UPUP

UP

UP

E

F

D

C

B

G

H

A

GYMNASIUM

SWIMMING

POOL

CORRIDOR

STAIR

STAIR

STAIR

STAIR

CORRIDOR

CORRIDOR

VEST.

190A

CORRIDOR

168 VESTIBULE

170A

CLO.

VEST.

100B

VEST.

100A

OFFICE

WOMEN'S RR

MEN'S RR

MECH.

VEST.

170D

ROTC

176E

ROTC

ROTC

176D

ROTC

176C

ROTC

176B

ROTC

176A

VEST.

150A

CORRIDOR

MECH.

VEST.

150B

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

NOT IN

CONTRACT

OFFICE

110A

OFFICE

CONF.

OFFICE

OFFICE

CORRIDOR

VESTIBULE

OFFICE

113A

OFFICE

113B

COMPUTER

LAB

C L

O

C

CLO.

110C

CLO.

110D

A101 A701

A101 A702

A101 A702

A101 A702

A101 A702

A7051

A704

1 A703 1

A706 1

09 72 01

A101 A600

A101 A600

09 91 01

09 91 01 09 91 01

09 91 03

09 91 09

09 91 10

09 91 10

09 91 09

09 91 03

09 91 03

09 91 01

09 91 01

09 91 01

08 11 02

08 11 02

09 91 01

09 91 01

09 91 01

09 91 01

09 91 01

09 91 01

08 11 02

09 91 01

11 20 04

09 91 01

09 91 01

09 91 01

09 91 01

09 72 02

08 11 01

09 72 08

09 91 01

09 91 03

09 91 01

22 47 01

OFFICE

110B

09 68 01

09 68 01

09 65 02

09 65 02

09 72 08

09 72 08

100A

100B

100C

100D

100E

100F

100G

100H

116A

1. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE

BUILDING CODES, ORDINANCES AND LAWS.

2. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE

CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM

THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.

3. DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF STUD, CENTERLINE OF

OPENINGS, AND CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED.

DIMENSIONS FOR EXISTING CONSTRUCTION IS TO FINISH FACE OF WALL UNLESS

OTHERWISE NOTED. REFLECTED CEILING PLAN DIMENSIONS ARE TO FINISH

FACE OF WALL.

4. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF

ANY DISCREPANCIES. CONTRACTOR IS TO NOTIFY THE ARCHITECT IMMEDIATELY

UPON DISCOVERY OF ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE

WORK.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF OTHER TRADES

AND WORK BETWEEN THE TRADES TO ENSURE A FULL AND COMPLETE JOB.

6. ALL CHANGES IN WORK COMPLETED WITHOUT APPROVAL FROM THE OWNER

SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR WHO SHALL INCUR

ALL COST INVOLVED.

7. ALL MATERIALS SHALL BE INSTALLED PER MANUFACTURERS WRITTEN

INSTRUCTIONS UNLESS OTHERWISE NOTED (U.O.N.).

8. LIKE OR SIMILAR CONDITIONS NOT SPECIFICALLY NOTED SHALL BE

CONSTRUCTED IN A MANNER CONSISTENT W/ LIKE OR SIMILAR WORK/ DETAILS.

9. NEW PARTITIONS AND MASONRY WALLS SHALL MATCH THICKNESS AND

MATERIALITY OF EXISTING. ALL NEW MASONRY SHALL TOOTH-INTO EXISTING.

10. ALL LOCATIONS WHERE DEMOLITION WORK DAMAGES ADJACENT EXISTING

PAINTED FINISH SURFACE, CONTRACTOR IS TO REPAIR, CLEAN, PRIME, AND

PAINT. MATCH ADJACENT FINISH.

11. UPON DISCOVERY OF ANY PENETRATIONS TO FIRE BARRIERS, CONTRACTOR TO

REFER TO UNIT PRICES SPECIFICATION.

12. GRAPHICS PACKAGE IS A WORK IN PROGRESS. CONTRACTOR TO COORDINATE

VINYL WALL GRAPHICS WITH NSU GRAPHICS DEPARTMENT.

ANDREW JOHN

Lic No. 15101

McKINLEY

O

W E

LA

HT

M N O M

C O

I

F V

A I

N I

R G

ER

A

HC TI

C T

DATE:

CHECKED BY:

SHEET STATUS:

KEY PLAN:

A

B

C

D

E

F

G

H

I

J

K

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

CONSULTANT:

1/16" = 1'-0"

20 30

1/8" = 1'-0"

108642 18161412

1/4" = 1'-0"

54321 9876

3/8" = 1'-0"

21 64 53 7

1/2" = 1'-0"

21 43 5

3/4" = 1'-0"

1 32

1" = 1'-0"

1 2 3

3/16" = 1'-0"

42 8631 75 9

1-1/2" = 1'-0"

3" = 1'-0"

GRAPHIC

SCALE

VIA PROJ #:

viadesignarchitects.com

319 E Plume Street Norfolk, VA 23510

757 627 1489

SHEET TITLE:

SHEET NUMBER:

PERMIT SET

STATE PROJ #:

2024.03.05

20009-07

A101

LEVEL 1 - NEW WORK -

FLOOR PLAN

Checker

G

IL

L H

E A

L T

H

P E

C

E

IL

IN

G

L

IG

H T

IN

G

I N

T E

R

IO

R F

IN

IS

H E

S U

P G

R A

D E

S

N o rf o lk

S ta te U n iv e rs it y

P a rk

A v e

N o rf o lk

V

A

2024.03.05

213-2324-009

1/16" = 1'-0"A600 A101

1 LEVEL 1 - NEW WORK - FLOOR PLAN

GENERAL NEW WORK NOTES

08 11 01 NEW DOOR, FRAME + HARDWARE, FIRE RATED. PERMANENT CENTER MULLION.

08 11 02 NEW DOORS, FRAMES, AND HARDWARE. ONE MULLION NEEDS TO BE

REMOVABLE. FIRE RATED DOORS + FRAMES. PANIC EGRESS HARDWARE THAT

CAN BE LOCKED TO PREVENT ACCESS FROM EXTERIOR BUT PERMITS EGRESS

FROM INTERIOR.

09 65 02 NEW WALL BASE.

09 68 01 NEW TILE CARPETING

09 72 01 NEW VINYL GRAPHIC WALL WRAP: NORFOLK MAP

09 72 02 NEW VINYL GRAPHIC WALL WRAP: NSU TIMELINE. REFERENCE RENDERING A

09 72 08 NEW VINYL GRAPHIC DOOR WRAP: GREEN AND GOLD SLASH. REFERENCE

GRAPHICS PACKAGE.

09 91 01 CLEAN, PRIME, AND PAINT EXISTING DOOR AND DOOR FRAME IN NSU GREEN.

09 91 03 CLEAN, PRIME, AND PAINT FULL LENGTH OF EXISTING AND NEW CMU WALL IN

CORRIDOR. MATCH EXISTING FINISH.

09 91 09 CLEAN, PRIME, AND PAINT EXISTING POOL BLEACHER HANDRAILS, AND BENCH

SUPPORT BRACKETS BLACK.

09 91 10 CLEAN, PRIME, AND PAINT EXISTING LOW WALL IN NSU GREEN, AND A 4" STRIPE

BELOW TILE WALL CAP IN NSU YELLOW. PROVIDE CLEAN CRISP CONSISTENT LINE

WHERE COLORS MEET.

11 20 04 RE-INSTALL EXISTING DRINK VENDING MACHINE

22 47 01 NEW DRINKING FOUNTAIN AND BOTTLE FILLING STATION. NEW RECEPTACLE

REQUIRED, SEE ELECTRICAL DRAWINGS.

KEYED NEW WORK NOTES

HIGH PERFORMANCE BUILDINGS ACT COMPLIANCE STATMENT

IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT

FROM COMPLIANCE BECAUSE THE COST OF THE RENOVATION DOES NOT EXCEED 50%

OF THE VALUE OF THE BUILDING

ASBESTOS DISCLOSURE STATEMENT

AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE

AREAS INDICATED. HOWEVER, THE WORK IN THIS PROJECT IS NOT INTENDED TO

DISTURB THE EXISTING ACM. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN

APPENDIX TO THE PROJECT SPECIFICATION

LEAD MATERIALS DISCLOSURE STATEMENT

AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS

HAS BEEN CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS

REPORT IS PROVIDED FOR THE CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT

IS THE CONTRACTOR’S RESPONSIBILITY TO COMPLY WITH ALL VIRGINIA OCCUPATIONAL

SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY PERTAIN TO EMPLOYEE

EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS SHALL BE

RECYCLED TO THE EXTENT POSSIBLE.

N

R E

V

IS

IO

N

S

D

A T

E D

E S

C R

IP

T

E

F

D

C

B

G

H

A

STAIR

OFFICE

OFFICE

CONF.

OFFICE

OFFICE

OFFICE

CONF.

OFFICE

211A

OFFICE

STAIR

CORRIDOR

CLO.

218A

CLO.

217A

V E

S T

STAIR

V E

S T

IB

U

L E

STAIR

OFFICE

OPEN TO

BELOW

OPEN TO

BELOW

A102 A701

A7051

A706 1

Sim

A101 A600

Sim

A101 A600

09 29 0609 29 05

09 29 04 09 29 04

A703 1

A7041

NOT IN

CONTRACT

NOT IN

CONTRACT

A501

A501

A501

A501

27 40 02

27 40 02

A501

OFFICE

CONF. RR

211B

09 91 16

1. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE

BUILDING CODES, ORDINANCES AND LAWS.

2. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE

CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM

THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.

3. DIMENSIONS FOR NEW CONSTRUCTION ARE TO FACE OF STUD, CENTERLINE OF

OPENINGS, AND CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED.

DIMENSIONS FOR EXISTING CONSTRUCTION IS TO FINISH FACE OF WALL UNLESS

OTHERWISE NOTED. REFLECTED CEILING PLAN DIMENSIONS ARE TO FINISH

FACE OF WALL.

4. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF

ANY DISCREPANCIES. CONTRACTOR IS TO NOTIFY THE ARCHITECT IMMEDIATELY

UPON DISCOVERY OF ANY UNFORESEEN CONDITIONS WHICH MAY ALTER THE

WORK.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF OTHER TRADES

AND WORK BETWEEN THE TRADES TO ENSURE A FULL AND COMPLETE JOB.

6. ALL CHANGES IN WORK COMPLETED WITHOUT APPROVAL FROM THE OWNER

SHALL BECOME THE RESPONSIBILITY OF THE CONTRACTOR WHO SHALL INCUR

ALL COST INVOLVED.

7. ALL MATERIALS SHALL BE INSTALLED PER MANUFACTURERS WRITTEN

INSTRUCTIONS UNLESS OTHERWISE NOTED (U.O.N.).

8. LIKE OR SIMILAR CONDITIONS NOT SPECIFICALLY NOTED SHALL BE

CONSTRUCTED IN A MANNER CONSISTENT W/ LIKE OR SIMILAR WORK/ DETAILS.

9. NEW PARTITIONS AND MASONRY WALLS SHALL MATCH THICKNESS AND

MATERIALITY OF EXISTING. ALL NEW MASONRY SHALL TOOTH-INTO EXISTING.

10. ALL LOCATIONS WHERE DEMOLITION WORK DAMAGES ADJACENT EXISTING

PAINTED FINISH SURFACE, CONTRACTOR IS TO REPAIR, CLEAN, PRIME, AND

PAINT. MATCH ADJACENT FINISH.

11. UPON DISCOVERY OF ANY PENETRATIONS TO FIRE BARRIERS, CONTRACTOR TO

REFER TO UNIT PRICES SPECIFICATION.

12. GRAPHICS PACKAGE IS A WORK IN PROGRESS. CONTRACTOR TO COORDINATE

VINYL WALL GRAPHICS WITH NSU GRAPHICS DEPARTMENT.

ANDREW JOHN

Lic No. 15101

McKINLEY

O

W E

LA

HT

M N O M

C…

This is the start of the file's text. The full file is on GovTribe.