210040_ATT11_Drawings_Final.pdf

PDF 7 MB Posted

Attached to
Repair Roof Sections 7, 8, 9, 10, 19, & 20, B3102
Solicitation number
WWYK210040
Issued by

About this file

These are architectural design drawings for a roof repair project at Building 3102 on Tinker Air Force Base, Oklahoma. The documents include detailed aerial images and technical drawings for repairing roof sections 7, 8, 9, 10, 19, and 20, featuring a 35% design stage not yet ready for construction. The project involves removing the existing built-up roof system, installing a new single-ply EPDM roof, reinstalling roof drains and exhaust vents, replacing parapet coping caps and flashing, and addressing expansion joints. Key requirements include coordinating with base users, ensuring building functionality, complying with UFC roofing standards, and working with the Tinker AFB State Historical Preservation Office to address any historical concerns. The estimated project magnitude ranges from $1,000,000 to $5,000,000, with a site visit scheduled for August 5, 2025, and the solicitation currently in draft stage.

View the file

Other files

File Type Posted
Solicitation - FA813725R0042.pdf PDF
210040_Hangar-3102 Drawing.pdf PDF
Site Visit Sign In Sheet.pdf PDF
210040 Government Response.pdf PDF
Solicitation - FA813725R0042.pdf PDF
Roof Shop Pages 3102.pdf PDF
03102A-FP02.pdf PDF
210040_ATT1_MACB_Design_Build_SOW_v3.pdf PDF
210040_ATT2_Design_Narrative_Final.pdf PDF
EAL List ATT 5 - BLANK to Contractors.xlsx XLSX spreadsheet
3102 Original.pdf PDF
83 Repair Roof Joints and Drains 3102.pdf PDF
03102A-FP01.pdf PDF
01 Emergency Roof Repair 3102.pdf PDF
210040_ATT3_Submittal_Register.xlsx XLSX spreadsheet
3102 Roof W Sections.pdf PDF
3102 Aerial.pdf PDF
88 Roof Repair 3102.pdf PDF
97 Renovate Flight Test 3102.pdf PDF
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R U

N W

A Y

R

U

N

W

T A

X I W

G

T

A

X

I

W

H

TAXIWAY B

TAXIWAY C

T

A

X

I

W

M

A

X I W

K

A

X

IW

A Y

E

TAXIWAY A

T

A

X

I

W

E

TAXIWAY F

TAXIWAY D

TAXIWAY E

T

A

X

I

W

J

A

X I W

G

A

X

IW

A Y

A

T

A

X

I

W

H

TAXIWAY C

TAXIWAY D

T

A

X

I

W

TAXIWAY F

C r u t c h o

C r e e k

K u h lm a n

C r e e k

K u h l m a n e e k

E l m e e k

E a s t u t c e e k

Elm Creek

E e e k

E e e k

E e e k

E e e k

E e e k

K u h l m e e k

E a u t c e e k

E e e k

West Crutcho Creek

W e s t

C r u t c h o

C r e e k

E e e k

E e e k

S o ld ie r

C r e e k

S o l d i e e e k

E a s t

C r u t c h o

C r e e k

E e e k

E a s t

C r u t c e e k

E a s t

C r u t c h o

C r e e k

S o l d i e e k

E a u t c e e k

S o l d i e r

C r e e k

S o l d i e e k

S o l d i e r

C r e e k

E a u t c e e k

E e e k

59475946

62540

61089

62509

62528

62523

62501X

43774

62512

62516

62525

35921

35916

99999

62543

32101

71086

53902

50414

55300

56601

930G

948-E

911-E

948-W

61019

911-W

33001

35913

62501

65672

930S

45134

43609

42116

62517

62515

62526

62527

62503

62513

61289

62542

62501OK

11289

99999

62501

15930

15908

15904

15904

15908

15908

15904

15904

15908

62502

41046

62501

62514

62501

61018

71089

99999

45134

96022

43120

41157

44045

45815

40592

40935

43610

62522

41163

15930

15930

11824

Arnold St.

E a s t

D r

SE 74th St

SE 59th St.

A i r

D e p o t

Patrol Rd.

S t a f f

D r

R e s e r v d

5th Ave

A

A v e

M u n i t i o

W a r e h o u

B

A v e

7th St.

H

A v e

M c N a r n e y

A v e

Mitchell Ave

A l e r t

R d

C o o k

A v e

W e s t

D r

E

A v e

Extender Dr.

Sentry Rd.

34th S t.

T w in in g D r

5th Ave.

J o n e s

Globemaster Dr.

T o w e r

R d

Vanaman Rd.

I n d u s t r i a l

B l v d

S o u

S

1st St.

D o o l i t t e

P i c n i c

R d

J a m e s

D r

W o l f

D

A i r

D e p o t

A i r

D e p o t

D

A v e

R a w l i n g s

A v e

P e r i m e t e r

R d

R a p c

R e s e r

L

A v e

Hercules /Mercury Rd.

F

A v e

1st St.

B r o w n

D r

P o n d

R d

O l d

A i r

D e p o t

A ir e y D r.

G e n e r

M t o

Bradley Dr.

Entrance Road "C"

Entrance Road "A"

C

A v e

C

A v e

G arden P lot R d.

H i l l t p

D o r m i t o r y

R d

D o r m i t o y

M

A v e

C h e n n a u lt

D r

M i t c h e e

V a n d e n b u rg

S t.

E n g i n e

T e s t

D r

Doolittle Ave

W h i t e

D r

3rd Ave.

D

D r i v e

B a l l

P a r k

R d

Joint STARS Dr.

A i r

D e p o t

B l v d

Turbine Dr.

T u r b in e D r

Central Plant Dr.

6th St.6th St.

F a l c

B l a c k b i

W e y l a o p

Propulsion Dr.

T h u n d e r b o

M uniti ons R

d. E xt.

C o d d in g R d

Starlifter Dr.

Chidlaw Ct.

C o r s a i r

D r

R a p t

N i g h t

H a w k

C t

P h a n t o m

D r

F r a n k l i n

P o w e r h o u

S k y m a s t e r

D r

Spaatz Ct.

L a w r e n c e

M u n d e l l

Nabors Dr.

I n t r u d e r

D r

M c N i c k l e

M i l l e r

D r

T a i l

F e a t h

H o l d

A i r y i r

S m i

R a v

M i t c h e e

A i p o t

A i r

D e p o t

Vanaman Rd.

1st St.

1st St.

TINKER AFB, OK

VICINITY MAP

EAKER GATE

FIRE DEPARTMENT

B117

BASE OPERATIONS

B240

CONTRACTING

B3

VANCE

GATE

GOTT

GATE

TINKER GATE

PASS & ID

B6611

LIBERATOR

GATE

HOPE

GATE

LANCER

GATE

TRUCK

GATE

PIAZZA

GATE

HRUSKOCY

GATE

BASE CIVIL ENGINEER

B400

PEGASUS

GATE

TAXIWAY C

G E

N E

R A

L

S H

E E

T

I N

D E

X

A

N D

V I C

I N

I T

Y

M

A P

G-001

D S

S G

A O

REVIEWED BY:

REVIEWED BY:

USING AGENCY:

ASBESTOS EVALUATION:

SAFETY:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

DATE:

INDUSTRIAL HYGIENE:

DATE:

SIGNATURES

CORROSION ENGINEER: (CECE)

CE OPERATIONS: (CECO)

COMMUNICATIONS: (COMM)

CHIEF ENGINEER DIR: (CECE)

CHIEF DESIGN BRANCH: (CECE)

DESIGN MANAGER: (CECE)

ZONE MANAGER:

CONSTRUCTION MANAGEMENT: (CECE)

ENVIRONMENTAL:

KEY PLAN:

BASE CIVIL ENGINEER: (CE)

FIRE DEPARTMENT: (CEFT)

PROJECT

LOCATION

PROJECT

LOCATION

WWYK210040

REPAIR ROOF SECTIONS

7,8,9,10,19, AND 20

B3102

PROJECT DRAWING INDEX

SHT. SHEET TITLE

G-001

SHEET INDEX AND VICINITY MAP

GENERAL

OF

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

TINKER AFB, OK

T I N

K E

R

A

I

F

O R

B

S

E

O

K L

A H

O M

A

P R

O J E

N

F O

R M

A T

I O

N R

E V

I S

I O

N S

M A

R K

D E

S I G

N

G

R O

U P

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

D E

S I G

N E

D

B

Y

D A

T E

D E

S C

R I P

T I O

N

2 3 4

E

D

C

B

A

M A

N A

G E

M E

F O

R M

A T

I O

N

1 2

E

D

C

B

A

I S

S U

E

D

A T

E

SHEET

SHEET NUMBER

S H

E E

T

T

I T

L E

D E

S I G

N

F

I L

C A

T I O

N

W W

Y K

R E

P A

O

F

S

E C

T O

I N

S

A

H D

R

35% DESIGN

NOT FOR

CONSTRUCTION

R-101

ARCHITECTURAL

RP101

DT101

RD101

AERIAL IMAGE OF B3102 SECTIONS 7,8,9,10,19, AND 20 - DEMOLITION

AERIAL IMAGE OF B3102 ROOF

AERIAL IMAGE OF B3102 SECTIONS 7,8,9,10,19, AND 20 - NEW WORK

B3102 SECTIONS 7,8,9,10,19, AND 20 - DETAILS

AE

IA

L

IM

AG

E O

F B3

R O

O F

R-101

AM

JS

R A

OF

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

TINKER AFB, OK

TI

N

KE

R

A

IR

F O

R C

E

BA

SE

, O

KL

AH

O M

A

PR

O

JE

C

T

IN

FO

R

M

AT

IO

N

R

EV

IS

IO

N S

M

AR

K

D

ES

IG

N

G R

O U

P:

D R

AW

N

B Y:

C H

EC

KE

D B

Y:

D

ES

IG

N

ED

B

Y:

D

AT

E D

ES

C

R

IP

TI

O

N

1 2 3 4 5

E

D

C

B

A

M

AN

AG

EM

EN

T

IN

FO

R M

AT

IO

N

1 2 3 4 5

E

D

C

B

A

IS

SU

E D

AT

E:

SHEET

SHEET NUMBER

SH

EE

T

TI

TL

E

D

ES

IG

N

F

IL

E

LO

C

AT

IO

N

W W

YK

R

EP

AI

R

R O

O F

SE

C

TO

IN

S 7, 8, 9, ,1

9, A

N D

B

/0

8/

H D

R

35% DESIGN

NOT FOR

CONSTRUCTION

KEY PLAN

BLDG 3102

PROJECT SITE

3 4

AERIAL IMAGE OF B3102 ROOF

SCALE: NTS

R-101

NIC

NIC

R I A

L

I M

A G

E

C

T I O

N S

A

D

E M

O L

I T

I O

N

RD101

A M

J S

R A

OF

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

TINKER AFB, OK

T I N

K E

R

A

R

S

E

O

K L

A H

O M

A

P R

O J E

F O

R M

A T

I O

N R

E V

I S

I O

N S

M A

R K

D E

S I G

N

G

R O

U P

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

D E

S I G

N E

D

B

Y

D A

T E

D E

S C

R I P

T I O

N

2 3 4

E

D

C

B

A

M A

N A

G E

M E

F O

R M

A T

I O

N

1 2

E

D

C

B

A

I S

S U

E

D

A T

E

SHEET

SHEET NUMBER

S H

E E

T

T

I T

L E

D E

S I G

N

F

I

C A

T I O

N

W W

Y K

R E

P A

O

F

S

E C

T O

I N

S

A

H D

R

35% DESIGN

NOT FOR

CONSTRUCTION

KEY PLAN

BLDG 3102

PROJECT SITE

AERIAL IMAGE OF B3102 ROOF

SECTIONS 7,8,9,10,19, AND 20 - DEMOLITION

SCALE: NTS

RD101

GENERAL NOTES:

1. DRAWINGS & SPECIFICATIONS ARE COMPONENTS OF

THE CONTRACT DOCUMENTS. REVIEW ALL DRAWINGS &

SPECIFICATIONS FOR THE COMPLETE SCOPE OF WORK.

NOTIFY CONTRACTING OFFICER IMMEDIATELY FOR

CLARIFICATION IF INCONSISTENCIES, CONTRADICTIONS,

OR OMISSIONS ARE DISCOVERED.

2. CONTRACTOR TO COORDINATE PHASING WITH USERS

AND CONTRACTING OFFICER TO PROVIDE ONGOING

FUNCTIONALITY OF BUILDING.

3. CONTRACTOR TO WALK ROOFS WITH GOVERNMENT /

USERS TO DETERMINE WHAT IS ABONDON AND WHAT IS

TO BE ROOFED OVER AND WHAT IS TO BE REPLACED.

4. CONTRACTOR IS TO DETERMINE BEST LOCATION /

SOLUTION FOR SECONDARY DRAINAGE AND TO ENSURE

TINKER AFB SHPO (STATE HISTORICAL PRESERVATION

OFFICE) IS IN AGREEMENT PRIOR TO DESIGN

SUBMISSION.

5. CONTRACTOR TO HAVE LEAD AND ASBESTOS TESTING

COMPLETED ON ROOF IN ITS ENTIRETY TO DETERMINE

WHAT MAY NEED REMOVED PRIOR TO GENERAL

DEMOLITION.

6. CONTRACTOR ROOFING DESIGN IS TO ACCOUNT FOR

INCREASED PARAPET HEIGHT IF NEEDED AND FLASHING

AGAINST ADJACENT MASONRY WALLS AND EJ'S. ROOF

MAY NEED ADDITIONAL/INCREASED SLOPE TO MEET

MINIMUM UFC-3-100-03 ROOFING SLOPE REQUIREMENTS.

7. CONTRACTOR TO REMOVE ALL LIGHTNING PROTECTION,

STORE FOR REINSTALLATION AFTER REROOFING.

8. ALL COMMUNICATION TO BE REMOVED BY GOVERNMENT

/USER AND REINSTALLED BY GOVERNMENT.

CONTRACTOR TO COORDINATE WITH USERS /

GOVERNMENT TO MAKE CONCESSIONS FOR REQUIRED

PENETRATIONS IN ROOFING AND CONCESSIONS FOR ALL

ROOF MOUNTED COMMUNICATIONS REQUIRED TO BE

SECURED.

REMOVE EXISTING BUILT UP ROOF SYSTEM PER

STATEMENT OF WORK.

REMOVE EXISTING ROOF DRAINS

REMOVE EXISTING ABANDONED CURBS, PENETRATIONS,

HATCHES AND OPENINGS. INFILL AS REQUIRED TO MATCH

ADJACENT CONSTRUCTION AND SYSTEM.

REMOVE EXISTING PERIMETER METAL FLASHING AND

COPING CAP.

REMOVE EXISTING MECHANICAL UNIT AND CURB. COVER

AND PROTECT MECHANICAL UNIT FOR RE-INSTALLATION.

PROVIDE NEW CURB AT LOCATIONS AND RE-INSTALL UNIT.

ASSESS ALL ROOF CURBS TO DETERMINE IF 12" OF ROOF

FLASHING IS ACHIEVABLE TO ENSURE ROOF WARRANTY.

CONTRACTOR TO COORDINATE WITH ROOFING MFR. TO

DETERMINE CURB REPLACEMENT REQUIREMENTS TO

ENSURE ROOF IS WARRANTABLE.

REMOVE EXISTING EXPANSION JOINT COVER.

GOVERNMENT / USERS TO REMOVE ALL

COMMUNICATIONS EQUIPMENT, STORE OR DEMOLISH AS

REQUIRED.

LIGHTNING PROTECTION TO BE REMOVED AND STORED.

DEMO KEY NOTES:

IMAGES OF B3102 ROOF

SECTIONS 7,8,9,10,19, AND 20 - DEMOLITION

SCALE: NTS

RD101

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

NIC

NIC

(TYP.)

(TYP.)

NIC

NIC

NIC NIC

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

R I A

L

I M

A G

E

C

T I O

N S

A

N

W

R

K

RP101

A M

J S

R A

OF

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

TINKER AFB, OK

T I N

K E

R

A

R

S

E

O

K L

A H

O M

A

P R

O J E

F O

R M

A T

I O

N R

E V

I S

I O

N S

M A

R K

D E

S I G

N

G

R O

U P

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

D E

S I G

N E

D

B

Y

D A

T E

D E

S C

R I P

T I O

N

2 3 4

E

D

C

B

A

M A

N A

G E

M E

F O

R M

A T

I O

N

1 2

E

D

C

B

A

I S

S U

E

D

A T

E

SHEET

SHEET NUMBER

S H

E E

T

T

I T

L E

D E

S I G

N

F

I

C A

T I O

N

W W

Y K

R E

P A

O

F

S

E C

T O

I N

S

A

H D

R

35% DESIGN

NOT FOR

CONSTRUCTION

KEY PLAN

BLDG 3102

PROJECT SITE

AERIAL IMAGE OF B3102 ROOF

SECTIONS 7,8,9,10,19, AND 20 - NEW WORK

SCALE: NTS

RP101

GENERAL NOTES:

1. DRAWINGS & SPECIFICATIONS ARE COMPONENTS OF

THE CONTRACT DOCUMENTS. REVIEW ALL DRAWINGS &

SPECIFICATIONS FOR THE COMPLETE SCOPE OF WORK.

NOTIFY CONTRACTING OFFICER IMMEDIATELY FOR

CLARIFICATION IF INCONSISTENCIES, CONTRADICTIONS,

OR OMISSIONS ARE DISCOVERED.

2. CONTRACTOR TO COORDINATE WITH USERS AND

CONTRACTING OFFICER TO PROVIDE ONGOING

FUNCTIONALITY OF BUILDING ENTRY AND SOUTH SIDE

WAREHOUSE AREA..

3. NEW SECONDARY SCUPPER DRAINAGE LOCATION IS TO

BE LOCATED PER CONTRACTOR'S DESIGN. SCUPPER

SIZE IS TO BE SIZED PER ASHRAE STANDARDS.

4. ROOF DESIGN IS TO COMPLY WITH UFC 3-100-03 ROOFING

AND OTHER APPLICABLE UFC, TINKER STANDARDS.

5. PARAPETS AND CURBS MAY NEED TO BE RAISED ONCE

INSULATION SLOPE HAS BEEN DETERMINED.

6. CONTRACTOR TO COORDINATE ALL MODIFICATIONS

WITH TINKER AFB SHPO OFFICE TO ENSURE ANY AND ALL

HISTORICAL CONCERNS ARE ADDRESSED PRIOR TO

CONSTRUCTION.

7. LIGHTING PROTECTION, LIGHTING AND ELECTRICAL IS TO

BE REPLACED AFTER ROOF INSTALLATION HAS

OCCURRED.

8. CONTRACTOR TO COORDINATE ANY COMMUNICATIONS

PENETRATIONS AND CURBS NEEDED TO SECURE

COMMUNICATIONS. GOVERNMENT TO REINSTALL

COMMUNICATION EQUIPMENT.

NEW SINGLE PLY EPDM ROOF SYSTEM AS INDICATED IN

SOW

NEW ROOF DRAINS

REINSTALLED EXHAUST VENT ON NEW CURB.

NEW PARAPET COPING CAP AND FLASHING.

NEW EXPANSION JOINT.

LIGHTING AND ASSOCIATED ELECTRICAL TO BE

REINSTALLED.

NEW WORK KEY NOTES:

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

NIC NIC

NIC

NIC NIC NIC

(TYP.)

(TYP.)

(TYP.)

(TYP.)

(TYP.)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MEMBRANE EXTENDED

BELOW NAILER AND

SECURED

FASTENERS APPROX. 12''

O.C.

90 MIL WHITE EPDM

ROOF MEMBRANE

24 GAUGE PVDF COATED

SHEET-METAL COPING

TREATED WOOD NAILER

ATTACHED TO SUBSTRATE

AND SLOPED TO THE INTERIOR

OF THE ROOF

M

I N

I M

U M

F L

A S

H I N

G

H

E I G

H T

S

L

O

P

E

BONDING ADHESIVE

MEMBRANE ATTACHMENT STRIP

WITH SEAM PLATES AND FASTENERS.

REFERENCE MANUFACTURERS

REQUIREMENTS TO ACHIEVE THE 30

YEAR NDL WARRANTY

24 GAUGE PVDF

COATED SHEET-METAL

GRAVEL STOP

2 X 6 MIN. TREATED WOOD NAILER

ATTACHED TO SUBSTRATE

OVERALL THICKNESS TO

MATCH INSULATION

SELF-ADHERING MEMBRANE

FLASHING PER THE

MANUFACTURER'S

WARRANTY REQUIREMENTS

APPROX. 2''

BONDING ADHESIVE

SEALANT

SEALANT

WATER BLOCK

FIELD SHEET

EXTENDED

BELOW

BLOCKING

22 GAUGE

CONTINUOUS

CLEAT

MEMBRANE SHEET CLOSURE

SECURED AND ADHERED TO WALL

FLEXIBLE LINER WITH

COMPRESSIBLE INSULATION

F L A

S H

I N

G

H

E I G

H T

M

I N

I M

U M

24 GAUGE PVDF CAOTED

SHEET-METAL EXPANSION JOINT

COVER WITH T-TYPE CLEAT

S

L

O

P

E

REINFORCED MEMBRANE

ATTACHMENT STRIP WITH

SEAM PLATES AND FASTENERS

BONDING ADHESIVE

90 MIL WHITE EPDM ADHERED

MEMBRANE FLASHING

2 X 6 MIN. TREATED WOOD NAILER

ATTACHED TO SUBSTRATE

OVERALL THICKNESS TO

MATCH INSULATION

2 x 6 MIN. TREATED WOOD NAILER

ATTACHED TO SUBSTRATE

OVERALL THICKNESS TO

MATCH INSULATION

COMPRESSIBLE

INSULATION

FLEXIBLE LINER TO SERVE

AS INSULATION RETAINER

(ATTACHED TO TOP OF CURB)

D

E

F L

A S

H I N

G

H

E I G

H T

M

I N

I M

U M

FASTENERS

8'' O.C.

BOTH SIDES

FLEXIBLE WEATHERPROOF

MEMBRANE CLOSURE

24 GAUGE FACTORY PVDF

COATED SHEET-METAL EXPANSION

JOINT COVER WITH T-TYPE CLEAT

S

L

O

P

E

90 MIL EPDM ADHERED

MEMBRANE FLASHING

SEALANT

SEAM PLATES

AND FASTENERS

BONDING ADHESIVE

TOP OF CURB TO

DRAIN TO ONE SIDE

SHEET-METAL SCUPPER

SECURED TO WALL AND

DECK AND/OR OPTIONAL

WOOD BLOCKING--SEE

NOTES 4 AND 5

TERMINATION OF

MEMBRANE FLASHING WILL

VARY

BONDING ADHESIVE

SEALANT (IF REQUIRED

FOR SPECIFIC SYSTEM)

BONDING ADHESIVE

SEALANT (IF REQUIRED

FOR SPECIFIC SYSTEM)

SEALANT WATER BLOCK

ADHERED MEMBRANE

FLASHING

OPTIONAL: TREATED WOOD

BLOCKING

TREATED WOOD

NAILER

PREFABRICATED METAL CURB

2 X 6 MIN. TREATED WOOD NAILER

ATTACHED TO SUBSTRATE

OVERALL THICKNESS TO

MATCH INSULATION

REINFORCED MEMBRANE

ATTACHMENT STRIP WITH

SEAM PLATES AND FASTENERS

ADHERED 90 MIL WHITE

EPDM MEMBRANE FLASHING

F L A

S H

I N

G

H

E I G

H T

M

I N

I M

U M

BONDING ADHESIVE

ROOFTOP EQUIPMENT FRAME

24 GAUGE REMOVABLE

SHEET-METALCOUNTERFLASHING

GASKETED FASTENER

MIN. TWO FASTENERS

PER SIDE

CORNER FLASHING PIECE

AT EACH CORNER

SEAL ALL EXPOSED EDGES

FASTENERS

APPROX. 8" O.C.

MIN. TWO PER SIDE

SEALANT

PRE-MANUFACTURED

MEMBRANE FLASHING

INSTALL SEALANT OR

SEALANT TAPE

BETWEEN PIPE AND

PRE-MANUFACTURED

MEMBRANE FLASHING

PLUMBING VENT STACK

DRAWBAND

SEALANT

F L A

S H

I N

G

H

E I G

H T

M

I N

I M

U M

CAST-IRON DRAIN BOWL

CLAMPING RING

ROOF DECK

PROPERLY SUPPORTED AT DRAINS

ROOF DRAIN HEIGHT FROM DECK

MAY VARY

DRAIN STRAINER

TAPERED INSULATION

SUMP

INSTALL COMPATIBLE SEALANT

BETWEEN DRAIN BOWL FLANGE

AND ROOF MEMBRANE

ROUND CUT IN MEMBRANE

EXTENDED APPROX. 1" PAST

CLAMPING RING. HOLE IN

MEMBRANE SHALL BE LARGER

THAN DRAIN PIPE DIAMETER

SEALANT WATER BLOCK

2 X 6 MIN. TREATED WOOD

NAILER ATTACHED TO

SUBSTRATE OVERALL

THICKNESS TO MATCH

INSULATION

SHEET-METAL GUTTER

THE FRONT OF THE GUTTER

SHOULD BE A MIN. 1'' LOWER

THAN THE BACK TO ALLOW

OVERFLOW

18 GAUGE GUTTER

BRACKET SUPPORT

SEALANT

ADHERED MEMBRANE FLASHING

PER THE MANUFACTURER'S

WARRANTY PER THE

MANUFACTURER'S

WARRANTY REQUIREMENTS

24 GAUGE PVDF

SHEET-METAL

EDGE FLASHING

18 GAUGE GUTTER SPACERS

INSTALLED 12" OC BETWEEN

GUTTER BRACKETS

BONDING

ADHESIVE

FIELD SHEET OR

SEPARATE MEMBRANE

SHEET EXTENDED BELOW

BLOCKING

24 GAUGE PVDF

COATED SHEET

METAL GUTTER

SEALANT (IF REQUIRED FOR

THE SPECIFIC SYSTEM)

WEATHERPROOF SHEET-METAL

PENETRATION POCKET--

SEE NOTES 3 AND 4

NONSHRINK

GROUT

ADHERED MEMBRANE FLASHING

EXTEND 1'' MIN. INTO

PENETRATION POCKET

ADHESIVE

OPTIONAL: SHEET-METAL

RAIN COLLAR OVERLAPPING

PENETRATION POCKET WITH

APPROPRIATE SEALANT

(E.G., POLYURETHANE) AND

DRAWBAND

2" APPROX.

POURABLE SEALANT

CORNER FLASHING PIECE AT

EACH CORNER--SEAL ALL

EXPOSED EDGES

B

S E

C T

I O

A

E T

A I L

S

DT101

A M

J S

R A

OF

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

TINKER AFB, OK

T I N

K E

R

A

R

S

E

O

K L

A H

O M

A

P R

O J E

F O

R M

A T

I O

N R

E V

I S

I O

N S

M A

R K

D E

S I G

N

G

R O

U P

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

D E

S I G

N E

D

B

Y

D A

T E

D E

S C

R I P

T I O

N

2 3 4

E

D

C

B

A

M A

N A

G E

M E

F O

R M

A T

I O

N

1 2

E

D

C

B

A

I S

S U

E

D

A T

E

SHEET

SHEET NUMBER

S H

E E

T

T

I T

L E

D E

S I G

N

F

I

C A

T I O

N

W W

Y K

R E

P A

O

F

S

E C

T O

I N

S

A

H D

R

35% DESIGN

NOT FOR

CONSTRUCTION

TYPICAL DETAIL

SCALE: N.T.S

DT101

TYPCAL DETAIL

SCALE: N.T.S

DT101

TYPICAL DETAIL

SCALE: N.T.S

DT101

TYPICAL DETAIL

SCALE: N.T.S

DT101

TYPICAL DETAIL

SCALE: N.T.S

DT101

TYPICAL DETAIL

SCALE: N.T.S

DT101

TYPCAL DETAIL

SCALE: N.T.S

DT101

TYPCAL DETAIL

SCALE: N.T.S

DT101

TYPCAL DETAIL

SCALE: N.T.S

DT101

TYPCAL DETAIL

SCALE: N.T.S

DT101

File details come from the government source that posted it. Updated .