21-NT0044 Exhibit A Preliminary Site Information ITCs_RDCs v3.xlsx

XLSX spreadsheet 87 KB Posted

Attached to
C222--Site Surveys to Implement Data Center Facilities Monitoring Tool - RDCs and ITCs (VA-21-00012639)
Solicitation number
36C10B21R0006
Issued by

About this file

This document contains a preliminary device list and site information for implementing a data center facilities monitoring tool at various Regional Data Centers and Information Technology Centers. The Department of Veterans Affairs intends to issue a solicitation for site surveys to be conducted at the Orlando Regional Data Center to gather accurate facility device data in order to implement the monitoring tool. The surveys would inventory equipment such as UPS systems, PDUs, CRAC units, generators, fire alarm panels, leak detection systems, and environmental sensors. The goal is to integrate the collected data with the existing StruxureWare Data Center Expert solution and Nlyte Energy Monitoring Optimizer tool to provide centralized monitoring of electrical infrastructure, HVAC conditions, and the overall operational health of the computer rooms. Offerors should submit any questions by December 14, 2020 to the points of contact listed. The solicitation closing date is December 21, 2020 at 11:00 AM EST.

View the file

Other files

File Type Posted
RFP - 36C10B21R0006 - Final 22 DEC.pdf PDF
36C10B21R0006 0003.docx DOCX document
Exhibit B NEO Device Profiles Example Monitoring Points.xlsx XLSX spreadsheet
RFP QA December 16 updated.docx DOCX document
Exhibit A Preliminary Site Information ITCs_RDCs v4 21-NT0044 updated 16 Dec.xlsx XLSX spreadsheet
RFP - 36C10B21R0006 - Final 16 DEC.pdf PDF
36C10B21R0006 0002.docx DOCX document
RFP - 36C10B21R0006 - Final 8 DEC.pdf PDF
36C10B21R0006 0001.docx DOCX document
RFP - 36C10B21R0006 - Final.pdf PDF
36C10B21R0006_1.docx DOCX document
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Summary

Exhibit A
Regional Data Centers (RDCs) and Information Technology Centers (ITCs)
Preliminary Device List Summary
Base Task and Optional Tasks
SiteTask TypeEstimated Total Device Qty Per SiteEstimated Total Number of Monitoring Points Per Site
Orlando RDCBase901692
Cleveland RDCOptional Task 5.4.12334587
Brooklyn RDCOptional Task 5.4.212746
Temple RDCOptional Task 5.4.3791539
Little Rock RDCOptional Task 5.4.4231021
AITCOptional Task 5.5.156681
HITCOptional Task 5.5.237878
PITCOptional Task 5.5.36161
CRRCOptional Task 5.5.4571042
Orlando RDCOptional Task 5.5.5901692
Cleveland RDCOptional Task 5.5.6TBDTBD
Brooklyn RDCOptional Task 5.5.7TBDTBD
Temple RDCOptional Task 5.5.8TBDTBD
Little Rock RDCOptional Task 5.5.9TBDTBD
TOTAL68314039

Base Task Orlando RDC

Exhibit A
Orlando Regional Data Center
2500 S Lakemont Avenue, Room 134 A/B, Orlando, Florida, 32814
Preliminary Device List
Base Task
Site Category: New Deployment of Data Center Facilities Monitoring Tool - Full Survey
Device Type #QtyDevice Category NameManufacturerModel#Existing IP AddressEstimated Number of Monitoring Points Per DeviceTotal Number of Monitoring Points Per DeviceComments
12UPSEaton93PMYes3570
22PDU/RPPEatonEMS-PDUYes96192
314CRACAPCACRC100/ACPDX21-86Yes/No2535012-Yes, 2-No
40ATS
50Fire Alarm Panel
60Leak Detection System
70Generators
80Building Management Control System
90Emergency Power Master Control System
100Power Meters
1172PDU StripsAPC7563/7862/7863/7864/8861/8863Yes/No1510807-Yes, 65-No
120Environmental Sensors
130Battery Monitoring System
140Chiller Plant
TOTAL901692

Optionl Tsk 5.4.1 Cleveland RDC

Exhibit A
Cleveland Regional Data Center
1620 E 105th Street, Building Data Center North, Room BM-660, Cleveland, Ohio, 44106
Preliminary Device List
Optional Task 5.4.1
Site Category: New Deployment of Data Center Facilities Monitoring Tool - Full Survey
Device Type #QtyDevice Category NameManufacturerModel#Existing IP AddressEstimated Number of Monitoring Points Per DeviceTotal Number of Monitoring Points Per DeviceComments
10UPS
212PDU/RPPEatonNo961152
310CRACLiebertDH267W-AAEINo25250
41ATSAPCAP7721/AP8965No3535Rack ATS
50Fire Alarm Panel
60Leak Detection System
70Generators
80Building Management Control System
90Emergency Power Master Control System
100Power Meters
11210PDU StripsAPCAP8965No153150
120Environmental Sensors
130Battery Monitoring System
140Chiller Plant
TOTAL2334587

Optional Tsk 5.4.2 Brooklyn RDC

Exhibit A
Brooklyn Regional Data Center
800 Poly Place, Building 14, Brooklyn, New York, 11209
Preliminary Device List
Optional Task 5.4.2
Site Category: New Deployment of Data Center Facilities Monitoring Tool - Full Survey
Device Type #QtyDevice Category NameManufacturerModel#Existing IP AddressEstimated Number of Monitoring Points Per DeviceTotal Number of Monitoring Points Per DeviceComments
12UPSLiebertYes3570
26PDU/RPPLiebertYes/No965764-Networked 2-Not Networked
34CRACLiebertYes/No251003-Networked 1-Not Networked
40ATS
50Fire Alarm Panel
60Leak Detection System
70Generators
80Building Management Control System
90Emergency Power Master Control System
100Power Meters
110PDU Strips
120Environmental Sensors
130Battery Monitoring System
140Chiller Plant
TOTAL12746

Optional Task 5.4.3 Temple RDC

Exhibit A
Temple Regional Data Center
1901 Veterans Memorial Drive, Building 222, Room 106, Temple, Texas, 76504
Preliminary Device List
Optional Task 5.4.3
Site Category: New Deployment of Data Center Facilities Monitoring Tool - Full Survey
Device Type #QtyDevice Category NameManufacturerModel#Existing IP AddressEstimated Number of Monitoring Points Per DeviceTotal Number of Monitoring Points Per DeviceComments
10UPS
24PDU/RPPEatonEMS-PDUYes96384
33CRACLiebertCW181DC1A1A149No2575No NIC Cards
40ATS
50Fire Alarm Panel
60Leak Detection System
70Generators
80Building Management Control System
90Emergency Power Master Control System
100Power Meters
1172PDU StripsAPCAP8965Yes151080
120Environmental Sensors
130Battery Monitoring System
140Chiller Plant
TOTAL791539

Optnl Tsk 5.4.4 Little Rock RDC

Exhibit A
Little Rock Regional Data Center
2200 Fort Roots Drive, Building 102, Room 104, North Little Rock, Arkansas, 72114
Preliminary Device List
Optional Task 5.4.4
Site Category: New Deployment of Data Center Facilities Monitoring Tool - Full Survey
Device Type #QtyDevice Category NameManufacturerModel#Existing IP AddressEstimated Number of Monitoring Points Per DeviceTotal Number of Monitoring Points Per DeviceComments
12UPSEaton9395Yes3570
26PDU/RPPEatonEMS-RPPYes96576
315CRACDataAiregForceIR/gForceNo25375
40ATS
50Fire Alarm Panel
60Leak Detection System
70Generators
80Building Management Control System
90Emergency Power Master Control System
100Power Meters
110PDU Strips
120Environmental Sensors
130Battery Monitoring System
140Chiller Plant
TOTAL231021

Optional Task 5.5.1 AITC

Exhibit A
Austin Information Technology Center (AITC)
1615 Woodward Street, Austin, TX 78772
Preliminary Device List
Optional Task 5.5.1 - Additional Devices
Site Category: Existing Deployment of Data Center Facilities Monitoring Tool - Partial Survey
Device Type #QtyDevice Category NameManufacturerModel#Existing IP AddressEstimated Number of Monitoring Points Per DeviceTotal Number of Monitoring Points Per DeviceComments
10UPS
20PDU/RPP
30CRAC
45ATSUnknownUnknownUnknown35175Accessible through existing DMC interface
50Fire Alarm Panel
61Leak Detection SystemLiebertLiquitectNo66160D
70Generators
80Building Management Control System
90Emergency Power Master Control System
100Power MetersSchneider ElectricUnknownNo
1150PDU Strips with Environmental SensorsVariousNo10500
120Environmental SensorsUnknownUnknownYesFor Data Center Racks and HVAC Systems in Telecom Closets
130Battery Monitoring SystemEatonCellwatchNo24 batteries
140Chiller PlantTraneCVHF1070No
TOTAL56681

Optional Task 5.5.2 HITC

Exhibit A
Hines Information Technology Center (HITC)
5000 South 5th Avenue, Building 215, Hines, IL 60141
Preliminary Device List
Optional Task 5.5.2 - Additional Devices
Site Category: Existing Deployment of Data Center Facilities Monitoring Tool - Partial Survey
Device Type #QtyDevice Category NameManufacturerModel#Existing IP AddressEstimated Number of Monitoring Points Per DeviceTotal Number of Monitoring Points Per DeviceComments
10UPS
20PDU/RPPAPCOG-PDRPPNX10/OG-PD80G6FK1-M1
319CRACLiebert/Schneider/VertivDH267WVAAOGS984/Uniflair/DA085UP1AD299ANo25475Available via new DDC System. 17 Lieberts, 1 Schneider, 1 Vertiv
40ATS
52Fire Alarm PanelFike/KiddieCheeta XINo612Determine dry contract status
60Leak Detection SystemMulti Zone
74Generators/Control PanelCummins/GE900DFJC/Series 90-30 PLCNo60240Available via new DDC System
80Building Management Control System
90Emergency Power Master Control System
100Power Meters
110PDU Strips
120Environmental Sensors
131Battery Monitoring SystemEatonCellwatchNo30303 Battery Chains. Available via new DDC System
140Chiller PlantTraneCVHF1070No
151Mechanical Plant ControlUnknownUnknownNo2525Available via new DDC System
161Sprinkler SystemVikingTotak Pak 2 Preaction SystemNo66Available via new DDC System
176Transient Voltage Suppression SwitchesLiebert/SurgelogicNo1060Require extensive new conduit/cabling to monitor
183Air Handler UnitAmerican Auto-MatrixNo1030Available via new DDC System
TOTAL37878

Optional Task 5.5.3 PITC

Exhibit A
Philadelphia Information Technology Center (PITC)
5000 Wissahickon Avenue, Philadelphia, PA 19144
Preliminary Device List
Optional Task 5.5.3 - Additional Devices
Site Category: Existing Deployment of Data Center Facilities Monitoring Tool - Partial Survey
Device Type #QtyDevice Category NameManufacturerModel#Existing IP AddressEstimated Number of Monitoring Points Per DeviceTotal Number of Monitoring Points Per DeviceComments
10UPS
20PDU/RPP
30CRAC
41ATSUnknown3535Modbus connection
50Fire Alarm Panel
61Leak Detection System66
70Generators
80Building Management Control System
90Emergency Power Master Control System
100Power Meters
110PDU Strips
120Environmental Sensors
130Battery Monitoring System
142Chiller Plant & Chilled Water Loop PumpsUnknown50100Chiller 4 & 5. Bacnet connection
182Air Handler UnitUnknown1020Existing and new
TOTAL6161

Optional Task 5.5.4 CRRC

Exhibit A
Capital Regional Readiness Center (CRRC), Martinsburg, West Virginia
221 Butler Ave, Bldg. 511, Martinsburg, WV 25405
Preliminary Device List
Optional Task 5.5.4 - Additional Devices
Site Category: Existing Deployment of Data Center Facilities Monitoring Tool - Partial Survey
Device Type #QtyDevice Category NameManufacturerModel#Existing IP AddressEstimated Number of Monitoring Points Per DeviceTotal Number of Monitoring Points Per DeviceComments
10UPSUnknownUnknownYes350
20PDU/RPPUnknownUnknownYes960
30CRACUnknownUnknownUnknown250
44ATSUnknownUnknownUnknown35140
51Fire Alarm PanelUnknownUnknownYes66
61Leak Detection SystemUnknownUnknownUnknown66
70GeneratorsUnknownUnknownYes600
81Building Management Control SystemUnknownUnknownYes100100
91Emergency Power Master Control SystemUnknownUnknownYes100100
100Power MetersUnknownUnknownYes350
1140PDU StripsAPC7811/7863/7961Yes15600
129Environmental SensorsUnknownUnknownYes1090
TOTAL571042