Technical Clarifier Drawings Summary

This document set consists of record drawings for clarifier enhancements and two new secondary clarifiers at the Lane County, Oregon MWMC Primary and Secondary treatment facility serving the Eugene-Springfield area under contract number P80033. The drawings, prepared by CH2M Hill and dated January 2006 with record drawing revisions in July 2008, provide comprehensive mechanical and civil plans for the secondary clarifier complex expansion. The project includes detailed specifications for two new secondary clarifiers (numbered 9 and 10), modifications to existing secondary clarifiers (numbers 1-8), sediment and erosion control measures, and construction entrance requirements. The drawings specify protection of existing clarifiers 4 and 8 during construction, installation of biofilter bag inlet barriers, gravel construction entrances, sediment fencing, and maintenance of one-lane traffic access with flaggers along the roadway. Key mechanical specifications include new clarifier mechanisms with 52-inch to 60-inch center columns, various piping configurations (ranging from 1-inch to 54-inch diameter), scum troughs, density current baffles, spray nozzles, and automated gate systems for influent, launder, and drain control. The drawings indicate coordination requirements with clarifier mechanism manufacturers for field verification of elevations and dimensions, and contractor responsibility for designing and restoring a concrete wash area.

The technical drawings establish precise elevation data (including top of grout elevations at 395.36 feet), clarifier radii specifications (65-foot and 60-foot 10-inch configurations), and detailed mechanical component locations and connections. All drawings are marked as record drawings with notation that they were prepared partially on basis of information compiled by others, with the engineer disclaiming responsibility for errors or omissions. The document set includes plan views at 1/8-inch scale, typical sections and details at 3/16-inch scale, and mechanical schematic diagrams. The work includes installation of new walkways, FRP (fiber-reinforced plastic) components including v-notch weirs and scum baffles, water cannons, sludge blanket detectors, and comprehensive piping and valve systems. A critical note prohibits dewatering clarifiers if adjacent groundwater is above the lowest point of the clarifier floor slab, indicating careful environmental and geotechnical coordination requirements during construction.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3

0 30 60 90

Scale In Feet

N

PROTECT

EXISTING

CLARIFIERS

NO. 4 AND

NO. 8 DURING

CONSTRUCTION

NEW SECONDARY

CLARIFIER 10

PROVIDE BIOFILTER

BAG INLET BARRIER

NEW SECONDARY

CLARIFIER 9

CONSTRUCT GRAVEL

CONSTRUCTION ENTRANCE

12’

MIN

CONSTRUCT GRAVEL

CONSTRUCTION ENTRANCE 2710

N 2155.00

E 3524.85

INSTALL SEDIMENT

FENCE AS SHOWN

PROVIDE BIOFILTER

BAG INLET BARRIER

PROVIDE BIOFILTER

BAG INLET BARRIER

NEW ML CHANNEL

L A

N E C

O U

N T

Y

O R

E G

O N

C L

A R

IF

IE

R E

N H

A N

C E

M E

N T S A

N D T

W O

N E

W S

E C

O N

D A

R Y C

L A

R

IF

IE

R S P

M W

M C P

R

IM

A R

Y A

N D S

E C

O N

D A

R Y

328092

E U

G E

N E -S

P R

IN

G F

IE

L D

M L

IT

T L E

S

IT

E D

E V

E L

O P

M E

N T

S E

C O

N D

A R

Y C

L A

R

IF

IE

R

S E

D

IM

E N

T A

N D E

R O

S

IO

N C

O N

T R

O L P

L A

N

05-CL-102

W W

A G

N E

R D E

V A

N S

JANUARY 2006

MAINTAIN ONE-LANE ACCESS

ALONG ROAD. PROVIDE FLAGGERS

AS NEEDED TO ALLOW SAFE FLOW

OF TRAFFIC

NEW ACCESS PLATFORM,

TYP OF 8 EXISTING

CLARIFIERS

M N

O E

S E

N

RECORD DRAWINGS

Revisions Drawn By Date

THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN PART, ON

THE BASIS OF INFORMATION COMPILED BY OTHERS. THEY ARE

NOT INTENDED TO REPRESENT IN DETAIL THE EXACT LOCATION,

TYPE OF COMPONENT NOR MANNER OF CONSTRUCTION. THE

ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR

OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THE

RECORD DRAWINGS.

JH BAUM JULY 2008

NOTE:

1. CONTRACTOR IS TO DESIGN CONCRETE WASH AREA

THAT WILL CONTAIN EXCESS CEMENT AND CONCRETE

WASHED DURING CONSTRUCTION. UPON COMPLETION

OF WORK, CONTRACTOR SHALL RESTORE CONCRETE

WASH AREA TO ORIGINAL OR BETTER CONDITION.

EXISTING FENCE

REMOVEDEXISTING FENCE

REMOVED

NEW FENCE,

TYP

PROJ

DATE

D A

T E

N O

D S

G N

D R

R E

V

IS

IO

N

C H

K

A P

V D

B Y

A P

V D c

IS

S U

E D F

O R

R

E V

IE

W

SHEET

DWG

FILENAME: PLOT DATE: PLOT TIME:05ncl102d_328092.dgn 8/14/2008 4:22:17 PM

C H

M H

IL

L

A

L L R

IG

H T S R

E S

E R

V E

D

1 2 3 4 5 6

A

B

C

D

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

1"0

C H

M H

IL

L A

N D I S N

O T T

O B

E U

S E

D

IN

W

H O

L E O

R I

N P

A R

T F

O R A

N Y O

T H

E R P

R O J E

C T W

IT

H

O U

T T

H E W

R

IT

T E

N A

U T

H O

R

IZ

A T

IO

N O

F C

H

M H

IL

L

T H

IS

D

O C

U M

E N

T

A N

D T

H E I

D E

A S A

N D D

E S

IG

N S I

N C

O R

P O

R A

T E

D H

E R

E

IN

A S A

N I

N S

T R

U M

E N

T O

F P

R O

F E

S S

IO

N A

L S

E R

V

IC

E

IS

T

H E P

R O

P E

R T

Y O

F R

E U

S E O

F D

O C

U M

E N

T S

S O

C

IA

T E

S

C O

N S

U L

T

IN

G

G

IN

E E

R S a s t

B r o a d w y u it e

E u g e n e

O r e g o n

F A

X

M W

M C C

O N

T R

A C

T

N O P

F O

R

S

IG

N A

T U

R E

S

A N

D S

E A

L S R

E F

E R

T O O

R

IG

IN

A L

D R

A W

IN

G S

D A

T E

D

J A

N U

A R

Y

R E

C O

R D D

R A

W

IN

G -2

J H

B M

G N

GATE GATEGATEGATE

II

W

GATE

W

W

W

GATE

W

SET IRSET IRSET IR

395395395395

I

W

E

W

I

GATE

W

W

GATE

E

W

E

SET IRSET IRSET IR

I

I

SET IRSET IRSET IRSET IR

E

SD

E

W W

E

E

E

E

E

E

WW

E

E

E

E

E

B-2

B-3

B-1

SC

#1

SC

#2

SC

#3

SC

#4

SC

#5

SC

#6

SC

#7

SC

#8

EXISTING SECONDARY CLARIFIER

COMPLEX KEY PLAN

CLARIFIER #6 PLAN

1/8"=1’-0"

N

R A D

IU

S 65’-0"

45°

45°

04DRE12-08

04DRE12-06

TOP OF GROUT

HPT EL 395.36

DIRECTION

OF ROTATION

EXISTING 48" ML

(CONCRETE ENCASED)

EXISTING 24" RAS

(CONCRETE ENCASED)

EXISTING 10" HS/D

EXISTING 6" SSM

L A

N E C

O U

N T

Y

O R

E G

O N

C L

A R

IF

IE

R E

N H

A N

C E

M E

N T S A

N D T

W O

N E

W S

E C

O N

D A

R Y C

L A

R

IF

IE

R S P

M W

M C P

R

IM

A R

Y A

N D S

E C

O N

D A

R Y

328092

E U

G E

N E -S

P R

IN

G F

IE

D

M

C H

A N

IC

A L

E X

IS

T

IN

G S

E C

O N

D A

R Y C

L A

R

IF

IE

R S

A

N D

T

Y P

IC

A L P

L

20-M-144

J B

A U

M A C

H A

N G

JANUARY 2006

SECONDARY #6 CLARIFIER

INFLUENT GATE

04HV10-06

04HV10-08

04FV10-06

04FV10-08

SECONDARY #6 CLARIFIER

EAST LAUNDER GATE

04HV12-06E

04HV12-08E

04HV12-06W

04HV12-08W

NOTE 1

40°

5°

135°

1’-0" 1’-0"

TOP OF GROUT

LPT EL 394.36

TOP OF GROUT

LPT EL 394.36

1’-0"

SECONDARY

CLARIFIER #6

MECHANISM

NOTE 4

46°

SECONDARY #6

CLARIFIER ROW GATE

DENSITY

CURRENT

BAFFLE

15201

’-0

" NOTE 3

NOTE 3

FRP SCUM BAFFLE

G

20-M-202

K C

L E

G G

M N

O E

S E

N

NOTES:

1. INSTALL NEW CLARIFIER MECHANISM. FIELD VERIFY ELEVATIONS AND

DIMENSIONS WITH THE CLARIFIER MECHANISM MANUFACTURER.

BRIDGE SHALL BE INSTALLED FLUSH TO THE EXISTING PLATFORM

AND SHALL HAVE THE SAME WALKWAY SURFACE ELEVATION AS THE

EXISTING PLATFORM.

2. INFORMATION SHOWN ON THIS PLAN IS TYPICAL FOR SECONDARY

CLARIFIER #3. EQUIPMENT TAGS SHOWN WITH ARE ASSOCIATED

WITH CLARIFIER #8.

3. PROVIDE DEEPENED SCUM BAFFLE 40’ AHEAD OF AND 10’ BEHIND SCUM

TROUGH. SCUM TROUGH OUTLET LOCATION SHALL BE COORDINATED WITH

THE MANUFACTURER AND IN ACCORDANCE WITH SPECIFICATION 11337.

4. REPAIR/REPLACE COATING/GROUT BASE SLAB TOPPINGS AS DIRECTED BY

ENGINEER.

5. REMOVE EXISTING W2 PIPING FROM ALONG EXISTING BRIDGE TO THE EXISTING

PVC COUPLING. CONNECT NEW W2 PIPING FROM NEW BRIDGE PER

SIMILAR FOR SECONDARY CLARIFIERS 6 AND 8. 1

20-M-201

FRP V-NOTCH WEIR,

TYPE B

6" V915 W/

EXTENSION STEM,

TYP OF 4

1" W2

1 1/2" W2

REMOVE AND REPLACE

EXISTING POST HYDRANT

WITH NEW 1 1/2" V238,

TYP OF 2

2" W2

4" W2

3" W2

SCUM TROUGH

AND BEACH,

NOTE 3

EDI WELL

1 1/2" V236

15162 SIM

2" WATER

CANNON

15120

FLOCCULATION FEED

2 1/2" W2, NOTE 5

SECONDARY #6 CLARIFIER

WEST LAUNDER GATE

’-0

SLUDGE BLANKET

DETECTOR

4NS

12-06

4NSH

12-06

4NSH

12-08

4NS

12-08

TORQ TORQ

HIHI

TORQ TORQ

HIHI

RECORD DRAWINGS

Revisions Drawn By Date

THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN PART, ON

THE BASIS OF INFORMATION COMPILED BY OTHERS. THEY ARE

NOT INTENDED TO REPRESENT IN DETAIL THE EXACT LOCATION,

TYPE OF COMPONENT NOR MANNER OF CONSTRUCTION. THE

ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR

OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THE

RECORD DRAWINGS.

JH BAUM JULY 2008

SAFETY BARS,

TYP OF 2

PROJ

DATE

D A

T E

N O

D S

G N

D R

R E

V

IS

IO

N

C H

K

A P

V D

B Y

A P

V D c

IS

S U

E D F

O R

R

E V

IE

W

SHEET

DWG

FILENAME: PLOT DATE: PLOT TIME:20nm144d_328092.dgn 8/18/2008 7:12:36 AM

C H

M H

IL

L

A

L L R

IG

H T S R

E S

E R

V E

D

1 2 3 4 5 6

A

B

C

D

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

1"0

C H

M H

IL

L A

N D I S N

O T T

O B

E U

S E

D

IN

W

H O

L E O

R I

N P

A R

T F

O R A

N Y O

T H

E R P

R O J E

C T W

IT

H

O U

T T

H E W

R

IT

T E

N A

U T

H O

R

IZ

A T

IO

N O

F C

H

M H

IL

L

T H

IS

D

O C

U M

E N

T

A N

D T

H E I

D E

A S A

N D D

E S

IG

N S I

N C

O R

P O

R A

T E

D H

E R

E

IN

A S A

N I

N S

T R

U M

E N

T O

F P

R O

F E

S S

IO

N A

L S

E R

V

IC

E

IS

T

H E P

R O

P E

R T

Y O

F R

E U

S E O

F D

O C

U M

E N

T S

S O

C

IA

T E

S

C O

N S

U L

T

G

IN

E E

R S o a d w it e

E u g e n e

O r e g o n

F A

X

M W

M C C

O N

T R

A C

T

N O P

F O

R

S

IG

N A

T U

R E

S

A N

D S

E A

L S R

E F

E R

T O O

R

IG

IN

A L

D R

A W

IN

G S

D A

T E

D

J A

N U

A R

Y

R E

C O

R D D

R A

W

IN

G -2

J H

B M

G N

Typical Secondary Clarifier 1-8

N E C

O U

N T

Y

O R

E G

O N

C L

A R

IF

IE

R E

N H

A N

C E

M E

N T S A

N D T

W O

N E

W S

E C

O N

D A

R Y C

L A

R

IF

IE

R S P

M W

M C P

R

IM

A R

Y A

N D S

E C

O N

D A

R Y

328092

E U

G E

N E -S

P R

IN

G F

IE

C H

A N

IC

A L

E X

IS

T

IN

G S

E C

O N

D A

R Y C

L A

R

IF

IE

R

20-M-201

B

A U

M A C

H A

N G

JANUARY 2006

A 3/16"=1’-0"

20-M-141

NEW 6" SSM,

NOTE 1

1’-0"

TYP

TYP OF 7 SPACES

BETWEEN 8 SPRAY

NOZZLES

15162 SIM

15193

SPRAY NOZZLES

SCUM TROUGH

AND BEACH

04EDRE12-01

SECONDARY #1 CLARIFIER

DRIVE

EDI

WELL

DENSITY

CURRENT

BAFFLE

52" CENTER

COLUMN

SLUDGE

HEADER

48" ML

24" RAS

4’-8"7’-0

FLEXIBLE

CONNECTION

TYPICAL SECTION

4’-0"4’-0" 10" 2" V300

1 1/2"

V300 1 1/2"

W2

TYP

1 1/2" W2

TO FAR SIDE

OF WALKWAY

1 1/2" W2

FROM FAIR SIDE

OF WALKWAY

FLOCCULATION

WELL

15201

NEW

WALKWAY

15162 SIM

SPRAY NOZZLE

15193

1" V300

DRAIN

CONNECT NEW 2 1/2" W2 TO

EXISTING PVC W2 AT COUPLING

2 1/2"’ W2

20-M-141

EXISTING 6" SSM

FROM ML CHANNEL

CONTROL STRUCTURE

HEADER/MANIFOLD DETAIL

3/16"=1’-0"

NEW 52"

CENTER

COLUMN

NOTE 3

NEW 24" RAS

3"

BUTT STRAP, NOTE 4

NOTES:

1. CONNECT TO EXISTING 6" SSM AND ROUTE TO NEW SCUM TROUGH.

USE LONG RADIUS ELBOWS AND/OR 45° ELBOWS WITH SLOPED PIPING.

2. CONTRACTOR TO VERIFIY AND COORDINATE ALL DIMENSIONS WITH

CLARIFIER MECHANISM MANUFACTURER.

3. CONTRACTOR TO CUT EXISTING 24" RAS TO BELOW THE CLARIFIER

FLOOR AS NECESSARY TO INSTALL ELBOW. COORDINATE ELBOW

FABRICATION AND CONNECTION TO THE CENTER COLUMN WITH

CLARIFIER MECHANISM MANUFACTURER.

4. WELD NEW PIPE ONTO EXISTING RAS PIPE AND NEW CENTER COLUMN.

REPAIR PIPE LINING AND PIPE COATING.

MANUFACTURERCONTRACTOR

T Y

P

IC

A L S

E C

T

IO

N A

N D D

E T

A

IL

S

K C

L E

G G

M N

O E

S E

N

W2 PIPING SCHEMATIC

20-M-142

20-M-143

20-M-144

1 1/2" V236

2" WATER

CANNON

15120

INSIDE

FLOCCULATION WELL

2 1/2" V300

CENTER

PLATFORM

2’-8"

3’-1.5"

*COORDINATE AND CONFIRM DIMENSIONS WITH CLARIFIER

MECHANISM MANUFACTURER.

1 1/2" V236

EL 396.35

FRP

SCUM BAFFLE

FRP

V-NOTCH WEIR,

TYPE B

6" V915 W/

EXTENSION STEM,

TYP OF 4

NTS

2" W2

1 1/2" W2

INSTALL 1/2" V300

IN 2" W2 PIPING

@ BOTTOM OF

VERTICAL RISER, TYP

2 1/2" UNION

2 1/2" V300

3/4" V300

3/4" W2

TYPE 1 SPRAY

NOZZLES LOCATED

IN SCUM TROUGH,

TYP OF 2

2" V300

2" UNION

TYPE 1, TYP

EXTEND NOZZELS TO

WITHIN 8" OF WATER SURFACE

RECORD DRAWINGS

Revisions Drawn By Date

THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN PART, ON

THE BASIS OF INFORMATION COMPILED BY OTHERS. THEY ARE

NOT INTENDED TO REPRESENT IN DETAIL THE EXACT LOCATION,

TYPE OF COMPONENT NOR MANNER OF CONSTRUCTION. THE

ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR

OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THE

RECORD DRAWINGS.

JH BAUM JULY 2008

PROJ

DATE

D A

T E

N O

D S

G N

D R

R E

V

IS

IO

N

C H

K

A P

V D

B Y

A P

V D c

IS

S U

E D F

O R

R

E V

IE

W

SHEET

DWG

FILENAME: PLOT DATE: PLOT TIME:20nm201d_328092.dgn 8/18/2008 7:13:23 AM

C H

M H

IL

L

A

L L R

IG

H T S R

E S

E R

V E

D

1 2 3 4 5 6

A

B

C

D

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

1"0

C H

M H

IL

L A

N D I S N

O T T

O B

E U

S E

D

IN

W

H O

L E O

R I

N P

A R

T F

O R A

N Y O

T H

E R P

R O J E

C T W

IT

H

O U

T T

H E W

R

IT

T E

N A

U T

H O

R

IZ

A T

IO

N O

F C

H

M H

IL

L

T H

IS

D

O C

U M

E N

T

A N

D T

H E I

D E

A S A

N D D

E S

IG

N S I

N C

O R

P O

R A

T E

D H

E R

E

IN

A S A

N I

N S

T R

U M

E N

T O

F P

R O

F E

S S

IO

N A

L S

E R

V

IC

E

IS

T

H E P

R O

P E

R T

Y O

F R

E U

S E O

F D

O C

U M

E N

T S

S O

C

IA

T E

S

C O

N S

U L

T

G

IN

E E

R S o a d w it e

E u g e n e

O r e g o n

F A

X

M W

M C C

O N

T R

A C

T

N O P

F O

R

S

IG

N A

T U

R E

S

A N

D S

E A

L S R

E F

E R

T O O

R

IG

IN

A L

D R

A W

IN

G S

D A

T E

D

J A

N U

A R

Y

R E

C O

R D D

R A

W

IN

G -2

J H

B M

G N

Typcal Secondary Clarifier 1-8

CLARIFIER #10 PLAN

1/8"=1’-0"

N

5 6

SC

#1

SC

#2

SC

#3

SC

#4

SC

#5

SC

#6

SC

#7

SC

#8

SC

#9

SC

#10

EXISTING AND NEW SECONDARY CLARIFIER

COMPLEX KEY PLAN

N

DIRECTION

OF ROTATION

R

AD

IU

S ’-1

0"

TOP OF GROUT

HPT EL 395.36

45°

40°

135°

04DRE12-10

6" SSM

RADIU

S 6

5’- 0"

30-M-201

H

15150

SECONDARY

CLARIFIER #10

MECHANISM

L A

N E C

O U

N T

Y

O R

E G

O N

C L

A R

IF

IE

R E

N H

A N

C E

M E

N T S A

N D T

W O

N E

W S

E C

O N

D A

R Y C

L A

R

IF

IE

R S P

M W

M C P

R

IM

A R

Y A

N D S

E C

O N

D A

R Y

328092

E U

G E

N E -S

P R

IN

G F

IE

C H

A N

IC

A L

N E

W S

E C

O N

D A

R Y C

L A

R

IF

IE

R

P

L

30-M-111

B

A U

M A C

H A

N

JANUARY 2006

04HV12-10W

04HV12-10E

SECONDARY #10 CLARIFIER

EAST LAUNDER GATE

3/4" W2

LOWER LEVEL PARTIAL PLAN

1/8"=1’-0"

8’ -2

5’ -7

10" UD, TYP

10" HS/D

30" RAS

54" ML

15201

FLOCCULATION WELL

45°

45°

CL WALKWAY

SCUM TROUGH

AND BEACH

’-0

50°

54" ML

10" HS/D

SE BOX

04FV10-10

04HV10-10

04DV10-10

SECONDARY #10 CLARIFIER

ROW AUTOMATIC GATE

SECONDARY #10

CLARIFIER INFLUENT GATE

SECONDARY #10 CLARIFIER

DRAIN GATE

SECONDARY #10 CLARIFIER

WEST LAUNDER GATE

K C

L E

G G

M N

O E

S E

N

1 1/2" W2

CL EL 392.75

3" W2

CL EL 392.75

NOTE 1

NOTE 1

FRP V-NOTCH WEIR,

TYPE B

FRP SCUM BAFFLE

DENSITY

CURRENT

BAFFLE

1 1/2" V238

TYPICALLY SPACED

100’ APART AROUND

CLARIFIER CIRCUMFERENCE

6" V915 W/

EXTENSION STEM,

TYP OF 4

30" RAS

PROVIDE DEEPENED SCUM BAFFLE 40’ AHEAD OF AND 10’

BEHIND SCUM TROUGH.

DO NOT DEWATER CLARIFIER IF ADJACENT GROUNDWATER

IS ABOVE LOWEST POINT OF THE CLARIFIER FLOOR SLAB.

NOTES:

1.

2.

EDI WELL

2" WATER

CANNON

15120

1 1/2" V236

15162 SIM

3" V410 W/

VALVE BOX

15642

50’

5’-0" SLUDGE BLANKET

DETECTOR

4LE

15-10

4NS

12-10

4NSH

12-10

TORQ TORQ

HIHI

SAFETY BARS,

TYP OF 2

RECORD DRAWINGS

Revisions Drawn By Date

THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN PART, ON

THE BASIS OF INFORMATION COMPILED BY OTHERS. THEY ARE

NOT INTENDED TO REPRESENT IN DETAIL THE EXACT LOCATION,

TYPE OF COMPONENT NOR MANNER OF CONSTRUCTION. THE

ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR

OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THE

RECORD DRAWINGS.

JH BAUM JULY 2008

3" W2

4" W2

PROJ

DATE

D A

T E

N O

D S

G N

D R

R E

V

IS

IO

N

C H

K

A P

V D

B Y

A P

V D c

IS

S U

E D F

O R

R

E V

IE

W

SHEET

DWG

FILENAME: PLOT DATE: PLOT TIME:30nm111d_328092.dgn 8/18/2008 8:11:39 AM

C H

M H

IL

L

A

L L R

IG

H T S R

E S

E R

V E

D

1 2 3 4 5 6

A

B

C

D

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

1"0

C H

M H

IL

L A

N D I S N

O T T

O B

E U

S E

D

IN

W

H O

L E O

R I

N P

A R

T F

O R A

N Y O

T H

E R P

R O J E

C T W

IT

H

O U

T T

H E W

R

IT

T E

N A

U T

H O

R

IZ

A T

IO

N O

F C

H

M H

IL

L

T H

IS

D

O C

U M

E N

T

A N

D T

H E I

D E

A S A

N D D

E S

IG

N S I

N C

O R

P O

R A

T E

D H

E R

E

IN

A S A

N I

N S

T R

U M

E N

T O

F P

R O

F E

S S

IO

N A

L S

E R

V

IC

E

IS

T

H E P

R O

P E

R T

Y O

F R

E U

S E O

F D

O C

U M

E N

T S

S O

C

IA

T E

S

C O

N S

U L

T

G

IN

E E

R S o a d w it e

E u g e n e

O r e g o n

F A

X

M W

M C C

O N

T R

A C

T

N O P

F O

R

S

IG

N A

T U

R E

S

A N

D S

E A

L S R

E F

E R

T O O

R

IG

IN

A L

D R

A W

IN

G S

D A

T E

D

J A

N U

A R

Y

R E

C O

R D D

R A

W

IN

G -2

J H

B M

G

Typical Clarifier 9-10

N E C

O U

N T

Y

O R

E G

O N

C L

A R

IF

IE

R E

N H

A N

C E

M E

N T S A

N D T

W O

N E

W S

E C

O N

D A

R Y C

L A

R

IF

IE

R S P

M W

M C P

R

IM

A R

Y A

N D S

E C

O N

D A

R Y

328092

E U

G E

N E -S

P R

IN

G F

IE

C H

A N

IC

30-M-202

B

A U

M A C

H A

N G

JANUARY 2006

A 3/16"=1’-0"

30-M-110

2 1/2" W2

2 1/2" BALL

VALVE

15162 SIM

1 1/2" W21’-0"

SCUM TROUGH

AND BEACH

6" SSM,

NOTE 1

SUCTION HEADER

04DRE12-09

EDI WELL

DENSITY

CURRENT

BAFFLE

60" CENTER

COLUMN

54" ML 30" RAS 10" HS/D

INV EL 371.40

INV EL 373.18

INV EL 375.40

INV EL 377.56

10" UD

N E

W S

E C

O N

D A

R Y C

L A

R

IF

IE

R S

W2 PIPING DETAIL

30-M-110

TYP OF 7 SPACES

BETWEEN 8 SPRAY

NOZZLES

4’-8"7’-0

15193

SPRAY NOZZLES

TYP

1 1/2"

W2

4’-0"4’-0" 10"

1 1/2"

V300

1 1/2" W2

FROM FAIR SIDE

OF WALKWAY

FLEXIBLE

CONNECTION

FLOCCULATION WELL

FRP SCUM BAFFLE

TYPICAL SECTION

T Y

P

IC

A L S

E C

T

IO

N A

N D D

E T

A

ILNOTES:

1.

2.

K C

L E

G G

M N

O E

S E

N

30-M-111 B

LOWER LEVEL SECTION

3/16"=1’-0"

30-M-110

54" ML

30" RAS

10" UD

HEAVY SOLIDS

HOPPER

60" CENTER

COLUMN

3’-0"

4’-9"

USE LONG RADIUS ELBOWS AND/OR 45° ELBOWS WITH SLOPED

PIPING.

DO NOT DEWATER CLARIFIER IF ADJACENT GROUNDWATER IS

ABOVE LOWEST POINT OF THE CLARIFIER FLOOR SLAB.

COORDINATE AND CONFIRM DINENSIONS WITH CLARIFIER

MECHANISM MANUFACTURUER.

NTS

FRP V-NOTCH WEIR,

TYPE B

1 1/2" V236

SECONDARY #9

CLARIFIER

DRIVE

SECONDARY #10

CLARIFIER

DRIVE

04DRE12-10

2" WATER

CANNON

15120

6" V915 W/

EXTENSION STEM

NEW

WALKWAY

15162 SIM

SPRAY NOZZLE

15193

1" V300

DRAIN

CONNECT NEW 2 1/2" W2 TO

EXISTING PVC W2 AT COUPLING

1 1/2" V236

2" WATER

CANNON

15120

INSIDE

FLOCCULATION WELL

2 1/2" V300

CENTER

PLATFORM

2" W2

1 1/2" W2

INSTALL 1/2" V300

IN 2" W2 PIPING

@ BOTTOM OF

VERTICAL RISER, TYP

2 1/2" UNION

2 1/2" V300

3/4" V300

3/4" W2

TYPE 1 SPRAY

NOZZLES LOCATED

IN SCUM TROUGH,

TYP OF 2

2" V300

2" UNION

TYPE 1, TYP

EXTEND NOZZELS TO

WITHIN 8" OF WATER SURFACE

RECORD DRAWINGS

Revisions Drawn By Date

THESE RECORD DRAWINGS HAVE BEEN PREPARED, IN PART, ON

THE BASIS OF INFORMATION COMPILED BY OTHERS. THEY ARE

NOT INTENDED TO REPRESENT IN DETAIL THE EXACT LOCATION,

TYPE OF COMPONENT NOR MANNER OF CONSTRUCTION. THE

ENGINEER WILL NOT BE RESPONSIBLE FOR ANY ERRORS OR

OMISSIONS WHICH HAVE BEEN INCORPORATED INTO THE

RECORD DRAWINGS.

JH BAUM JULY 2008

PROJ

DATE

D A

T E

N O

D S

G N

D R

R E

V

IS

IO

N

C H

K

A P

V D

B Y

A P

V D c

IS

S U

E D F

O R

R

E V

IE

W

SHEET

DWG

FILENAME: PLOT DATE: PLOT TIME:30nm202d_328092.dgn 8/18/2008 8:13:45 AM

C H

M H

IL

L

A

L L R

IG

H T S R

E S

E R

V E

D

1 2 3 4 5 6

A

B

C

D

VERIFY SCALE

BAR IS ONE INCH ON

ORIGINAL DRAWING.

1"0

C H

M H

IL

L A

N D I S N

O T T

O B

E U

S E

D

IN

W

H O

L E O

R I

N P

A R

T F

O R A

N Y O

T H

E R P

R O J E

C T W

IT

H

O U

T T

H E W

R

IT

T E

N A

U T

H O

R

IZ

A T

IO

N O

F C

H

M H

IL

L

T H

IS

D

O C

U M

E N

T

A N

D T

H E I

D E

A S A

N D D

E S

IG

N S I

N C

O R

P O

R A

T E

D H

E R

E

IN

A S A

N I

N S

T R

U M

E N

T O

F P

R O

F E

S S

IO

N A

L S

E R

V

IC

E

IS

T

H E P

R O

P E

R T

Y O

F R

E U

S E O

F D

O C

U M

E N

T S

S O

C

IA

T E

S

C O

N S

U L

T

G

IN

E E

R S o a d w it e

E u g e n e

O r e g o n

F A

X

M W

M C C

O N

T R

A C

T

N O P

F O

R

S

IG

N A

T U

R E

S

A N

D S

E A

L S R

E F

E R

T O O

R

IG

IN

A L

D R

A W

IN

G S

D A

T E

D

J A

N U

A R

Y

R E

C O

R D D

R A

W

IN

G -2

J H

B M

G

Typical Clarifier 9-10

Clarifier drawings.pdf
Secondary clarifier layout.pdf
Clarifier drawings.pdf
Pages from MWMC Clarifier As-built Record Drawings 082008-4.pdf
Pages from MWMC Clarifier As-built Record Drawings 082008-5.pdf

Clarifiers 1-8

File details come from the government source that posted it. Updated .