20260819_Revision_4_Asset_Protection_Volume_2_Sheet_C-637_Approved.pdf
PDF 606 KB Posted
- Attached to
- Asset Protection - Painting and Coating
- Solicitation number
- 630-0923-27
- Issued by
- Trinity County, California
About this file
This is a technical drawing document for the Solano County Downtown Fairfield Justice Campus Parking and Security Improvements project, involving the County of Solano, Department of General Services - Capital Projects Division, the City of Fairfield, and the Fairfield-Suisun Sewer District. The document (Sheet C-637, Revision 4) provides detailed specifications for security gate installations, specifically pedestrian gates for medium/high security and high security chainlink fencing applications. The drawing outlines gate post embedment in concrete footings, hinge configurations, hardware attachment points, and installation requirements for gates including Gate 14A, which requires County-approved locking hardware for latches and padlocks. Key specifications include gate post spacing of 3 feet maximum, footing clearances of 1 to 2 inches, and terminal post requirements of 8 inches maximum adjacent to pump station outfalls. The fencing contractor is responsible for designing and installing fence foundations and posts in accordance with local requirements and manufacturer specifications. The document was issued for construction on September 29, 2025, with subsequent revisions issued on July 31, 2026, August 11, 2026, and August 19, 2026, addressing RFI 22 responses.
The technical specifications require that all gate posts be squared for proper fit and clearance, chainlink be re-tensioned as needed, and all hardware be secured with tamper-proof fasteners. Field verification of actual swing direction is mandated before installation. The document references related drawing C-635 (Typical Fencing Details) and C/T-04-01 for hardware specifications, indicating this is part of a comprehensive multi-sheet technical package for the overall asset protection project designed to protect County properties from seasonal stormwater and flooding damage.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GATE SWINGS OUT TO
NON SECURE SIDE
FOR HARDWARE SEE C/T-04-01,
FOR GATE 14A SEE NOTE 1
2' 9'
EMBED GATE POST IN CONCRETE FOOTING,
TYP. FENCING CONTRACTOR TO DESIGN AND
INSTALL FENCE FOUNDATIONS AND POSTS IN
ACCORDANCE WITH LOCAL REQUIREMENTS
AND/OR MANUFACTURER REQUIREMENTS.
SEE GENERAL FENCE NOTES, C-635
(GATE SWINGS TO
NON SECURE SIDE)
HINGE SIDE
POST
CAP
FOR HARDWARE SEE C/T-04-01
H
EI
G H
T, S
EE
G
AT
E
SC
H
ED
U
LE
C
-6
WIDTH, SEE GATE
SCHEDULE C-630
C-637
SECURITY GATE
DETAILS II
SRS
MWR
DH
X:
\1
\1
4.
\T
EC
H \C
AD
\P
AR
KI
N G
L O
T
IM
PR
O
VE
M
EN
TS
\C -6
T
YP
IC
AL
F
EN
C
IN
G
D
ET
AI
LS
.D W
G
8/
/2
:0 7:
A
M
1943400-190824.01
SEPTEMBER 29, 2025
TE
XA
S
ST
R
EE
T
FA
IR
FI
EL
D
, C A
SHEET CONTENTS
DO NOT SCALE DRAWINGS
M&H NO.:
DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
ISSUED
These documents shall not be used for any purpose or project for which it is not intended. Mead & Hunt shall be indemnified by the client and held harmless and defended from all claims, damages, liabilities, losses, and expenses, including attorneys' fees and costs, arising out of such misuse or reuse of the documents.
In addition, unauthorized reproduction of these documents, in part or as a whole, is prohibited.
SHEET NO.
Mead and Hunt, Inc.
180 Promenade Circle, Suite 240 Sacramento, CA 95834 phone: 916-971-3961 meadhunt.com
2 07/31/2026 ISSUED FOR
CONSTRUCTION
1 9/29/2025 ISSUED FOR
CONSTRUCTION
3 08/11/2026 RFI 22
4 08/19/2026 RFI 22
PEDESTRIAN GATE - MEDIUM/HIGH SECURITY FENCING1 12" = 1'-0"
PEDESTRIAN GATE - HIGH SECURITY CHAINLINK FENCING2 1/2" = 1'-0"
SO
LA
N O
C O
U N
TY
D
O W
N
TO
W N
FA
IR
FI
EL
D J
U
ST
IC
E
C
AM
PU
S
PA
R
KI
N
G A
N D
S
EC
U R
IT
Y
IM
PR
O
VE
M
EN
TS
FENCE POST ADJACENT TO BUILDING3 NOT TO SCALE
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
1" MIN
2" MAX
SEE PLANS FOR FENCE TYPE
(TYP. ALL LOCATIONS)
TOP RAIL
FOOTING,
TYP
(E) BUILDING
WALL OR FENCE
1" MIN
2" MAX
TERMINAL POST
3' MAX
NOTE
1. LOCKING SYSTEM FOR GATE 14A SHALL BE SECURED WITH
COUNTY APPROVED HARDWARE FOR LATCH AND PADLOCK.
NOTES
1. SQUARE GATE POSTS AND GATE DOOR AS REQUIRED FOR
PROPER FIT AND TO PROVIDE REQUIRED CLEARANCES.
2. RE-TENSION CHAIN LINK AS REQUIRED FOR PROPER FIT.
3. SECURE ALL HARDWARE WITH TAMPER PROOF FASTENERS.
4. HINGE LOCATION IS DIAGRAMMATIC. FIELD VERIFY ACTUAL
SWING.
EMBED GATE POST IN CONCRETE FOOTING,
TYP. FENCING CONTRACTOR TO DESIGN AND
INSTALL FENCE FOUNDATIONS AND POSTS IN
ACCORDANCE WITH LOCAL REQUIREMENTS
AND/OR MANUFACTURER REQUIREMENTS.
SEE GENERAL FENCE NOTES, C-635
FENCE POST ADJACENT TO PUMP STATION OUTFALL4 NOT TO SCALE
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
1" MIN
2" MAX
SEE PLANS FOR FENCE TYPE
(TYP. ALL LOCATIONS)
TOP RAIL
FOOTING,
TYP
TERMINAL POST
8" MAX 8" MAX
PUMP STATION
OUTFALL
2" MAX
xx xx xx
8/19/2026
8/21/26: Reviewed for Revision 4/RFI 22 only.
-All bolts installed in concrete -Structural Masonry -Reinforcing steel placement -See Volume 1 sheet S-002
City of Fairfield
Fairfield-Suisun Sewer District
File details come from the government source that posted it. Updated .