This is a comprehensive plan set for Rhode Island Department of Transportation (RIDOT) Contract No. 2026-CB-046, a statewide steel repairs project involving seven bridges across Rhode Island municipalities. The project encompasses steel beam end repairs and asphaltic joint replacements at Bridge No. 086501 (Francis Street North, Providence), Bridge No. 063401 (Jefferson Boulevard, Warwick), Bridge No. 074101 (Putnam Pike, Smithfield), Bridge No. 092801 (Smith Street Railroad Bridge, Providence), Bridge No. 064401 (Sprague Street Bridge, Portsmouth), Bridge No. 076801 (Stony Lane Bridge, North Kingstown), and Bridge No. 055201 (Water Street Bridge, Pawtucket). The plans include 39 detailed sheets covering framing plans, various steel repair types specific to each bridge structure, joint repair details, and traffic control and detour plans. All construction must comply with the February 2026 edition of Rhode Island Standard Specifications for Road and Bridge Construction, the AASHTO LRFD Bridge Construction Specifications (4th Edition with 2020-2025 interim revisions), and referenced manuals, with special provisions governing conflicts between documents.
The construction scope requires certified bridge fabricators meeting AISC Advanced Bridge Fabricator (ABR) or equivalent certification with SSPC-QP3 paint certification, and steel erectors certified as Certified Bridge Fabricator Simple (SBR). All structural steel must meet AASHTO M 270 Grade 50 specifications with Zone 2 Charpy V-Notch fracture toughness testing requirements for nonfracture-critical components. Special provisions apply to work involving AMTRAK infrastructure, including coordination requirements, bonding and grounding specifications, protective barriers, signal preview distances of minimum 1500 feet, and specific engineering practices outlined in AMTRAK's EP3014 and EP3016 standards. The project incorporates maintenance and protection of traffic plans with specific lane closure and detour configurations for each bridge location, including overnight closures for certain work activities and early morning restrictions for Francis Street operations. All work must adhere to OSHA regulations for clearances to energized overhead lines and requires 72-hour advance notification to DIG SAFE for utility locating.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET NO. DESCRIPTION
1 COVER SHEET
2 STANDARD PLAN SYMBOLS & STANDARD LEGEND
3 STANDARD NOTES
4 LIST OF ABBREVIATIONS
5 BRIDGE NOTES 1 OF 2
6 BRIDGE NOTES 2 OF 2
FRANCIS STREET NORTH BRIDGE BR NO. 086501:
7 FRANCIS STREET NORTH BRIDGE OVER AMTRAK FRAMING PLAN
8 FRANCIS STREET NORTH BRIDGE OVER AMTRAK STEEL REPAIRS - TYPE 1
JEFFERSON BOULEVARD BRIDGE NO. 063401:
9 JEFFERSON BOULEVARD SOUTH BRIDGE FRAMING PLAN
10 JEFFERSON BOULEVARD SOUTH BRIDGE STEEL REPAIRS - TYPE 1
11 JEFFERSON BOULEVARD SOUTH BRIDGE STEEL REPAIRS - TYPE 2
12 JEFFERSON BOULEVARD SOUTH BRIDGE STEEL REPAIRS - TYPE 3
13 JEFFERSON BOULEVARD SOUTH BRIDGE STEEL REPAIRS - TYPE 4
14 JEFFERSON BOULEVARD SOUTH BRIDGE STEEL REPAIRS - TYPE 5
15 JEFFERSON BOULEVARD SOUTH BRIDGE STEEL REPAIRS - TYPE 6
16 JEFFERSON BOULEVARD SOUTH BRIDGE STEEL REPAIRS - TYPE 7
17 JEFFERSON BOULEVARD SOUTH BRIDGE STEEL REPAIRS - TYPE 8
18 JEFFERSON BOULEVARD SOUTH BRIDGE STEEL REPAIRS - TYPE 9
19 JEFFERSON BOULEVARD SOUTH BRIDGE STEEL REPAIRS - TYPE 10
PUTNAM PIKE BRIDGE NO. 074101:
20 US 44 PUTNAM PIKE OVER I-295 FRAMING PLAN
21 US 44 PUTNAM PIKE OVER I-295 STEEL REPAIRS - TYPE 1 AND TYPE 2
SMITH STREET R.R. BRIDGE NO. 092801:
22 SMITH STREET R.R. BRIDGE FRAMING PLAN
23 SMITH STREET R.R BRIDGE STEEL REPAIRS - TYPE 1
24 SMITH STREET R.R BRIDGE STEEL REPAIRS - TYPE 2
SPRAGUE STREET BRIDGE NO. 064401:
25 SPRAGUE STREET BRIDGE GENERAL PLAN
26 SPRAGUE STREET BRIDGE JOINT REPAIR DETAILS 1
27 SPRAGUE STREET BRIDGE JOINT REPAIR DETAILS 2
STONY LANE BRIDGE NO. 076801:
28 STONY LANE BRIDGE GENERAL PLAN
29 STONY LANE BRIDGE JOINT REPAIR DETAILS
WATER STREET BRIDGE NO. 055201:
30 WATER STREET BRIDGE FRAMING PLAN
31 WATER STREET BRIDGE STEEL REPAIRS -TYPE 1
32 WATER STREET BRIDGE STEEL REPAIRS -TYPE 2
33 WATER STREET BRIDGE STEEL REPAIRS -TYPE 3
34 WATER STREET BRIDGE STEEL REPAIRS -TYPE 4
TRAFFIC PLANS:
35 TRAFFIC GENERAL NOTES
36 TRAFFIC DETAILS 1 OF 2
37 TRAFFIC DETAILS 2 OF 2
38 SPRAGUE STREET DETOUR PLAN
39 RT 4 DETOUR PLAN
SPECIFICATIONS TO GOVERN THIS PROJECT ARE THE R.I. STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, AUGUST 2026,
WITH ALL REVISIONS AND THE STATE AND FEDERAL SPECIAL PROVISIONS
INCLUDED IN THE CONTRACT DOCUMENTS.
STANDARD DETAILS FOR THIS PROJECT ARE R.I. STANDARD DETAILS,
1998 EDITION, WITH ALL REVISIONS.
R.I. STANDARD SPECIFICATIONS AND STANDARD DETAILS
EXISTING NEW
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
STANDARD PLAN SYMBOLS AND
STANDARD LEGEND
STATEWIDE STEEL REPAIRS
UTILITY NOTES:GENERAL NOTES: MAINTENANCE AND PROTECTION OF TRAFFIC NOTES:
DEPARTMENT OF TRANSPORTATION
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
STANDARD NOTES
DEPARTMENT OF TRANSPORTATION
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
LIST OF ABREVIATIONS
SECTION & DETAIL DESIGNATIONS
DETAIL
X.X
X.X
DETAIL MARK
A X.X
SECTION
DETAIL TITLE
SECTION TITLE
SCALE:
SCALE:
LIST OF ABBREVIATIONS
A
ABUTMENT
ALTERNATE
ANCHOR BOLT
APPROVED
APPROXIMATE
AVENUE
B
BEAM
BACK TO BACK
BETWEEN
BEARING
BITUMINOUS
BUILDING
BUILDING LINE
BOLT CIRCLE
BOTTOM
C
CENTER TO CENTER
CENTERLINE
CIRCLE
CLEARANCE
COLUMN
CONCRETE
CONDUIT
CONNECTION
CONSTRUCTION
CONTRACTION
COUNTERSINK
COUPLING
D
DETAIL
DIAGONAL
DIAPHRAGM
DIAMETER
DIMENSION
DRAWING
DRAIN
E
EACH
EAST
ELEVATION
EXISTING
EXPANSION
F
FAR FACE
FABRICATE
FACE TO FACE
FLANGE
FLAT HEAD
FOOTING
FOUNDATION
FURNISH, FABRICATE & ERECT
G
GAGE
GALVANIZE
GRADE
GRATING
GROUND
H
HEIGHT
HEXAGON
HOT MIX ASPHALT
I
INCH
INFORMATION
INSIDE DIAMETER
INVERT
J
JOINT
L
LENGTH
LIGHTING
LONG
M
MATERIAL
MAXIMUM
MEAN HIGH WATER
MECHANICAL
MINIMUM
MISCELLANEOUS
N
NEAR FACE
NEAR SIDE
NOT TO SCALE
NUMBER
O
OBSERVED WATER
OPENING
OUTSIDE DIAMETER
OPTIONAL
P
PLATE
POINT OF VERTICAL CURVATURE
POINT OF VERTICAL TANGENCY
POLYVINYL CHLORIDE
POINT OF TANGENCY
R
RADIUS
RAILROAD
REQUIRED
REINFORCING
REHABILITATION
REMOVE & DISPOSE
S
SECTION
SCHEDULE
SCHEMATIC
SHEET
POUNDS PER SQUARE INCH
FAR SIDE = F.S.
= F.F. & E.
= FDN.
= FTG.
= F.H.
= FLG.
= F TO F
= FAB.
= F.F.
= EXP.
= EXIST.
= EL. OR ELEV.
= E.
= EA.
= DR.
= DWG.
= DIM.
= DIA. OR Ø
= DIAPHM.
= DIAG.
= DET.
= CPLG.
= CSK.
= CONTR.
= CONST.
= CONN.
= COND.
= CONC.
= COL.
= CL.
= CIR.
= C
= C TO C
= BOT.
= B.C.
= B.L.
= BLDG.
= BIT.
= BRG.
= BTWN
= B TO B
= BM.
= AVE.
= APPROX.
= APPD.
= A.B.
= ALT.
= ABUT.
L
= P.S.I.
= P.T.
= PVC
= P.V.T.
= P.V.C.
= P
= OPT.
= O.D.
= OPNG.
= O.W.
= NO. OR #
= N.T.S.
= N.S.
= N.F.
= MISC.
= MIN.
= MECH.
= M.H.W.
= MAX.
= MATL.
= LG.
= LTG.
= LGTH. OR L
= JT.
= INV.
= I.D.
= INFO.
= IN.
= HMA.
= HEX.
= HGT.
= GND.
= GRTG.
= GR.
= GALV.
= GA.
L
= SH.
= SCHEM.
= SCH.
= SECT.
= R & D
= REHAB.
= REINF.
= REQD.
= RR
= RAD. OR R
POUNDS PER SQUARE FOOT = P.S.F.
CLASS I CONTROLLED LOW
= CLSMSTRENGTH MATERIAL
LOAD & RESISTANCE
FACTOR DESIGN = LRFD
ADDITIONAL = ADD'L
AND = &
APPROACH = APPR.
AT EACH = @
AVERAGE = AVG.
BASELINE = BL
BOTTOM OF = B.O.
= C.F.CUBIC FEET
DOWN = DN.
EACH FACE = E.F.
EMBEDMENT = EMBED.
EQUAL = EQ.
FEET = FT.
FORCE MAIN = FM
GAS = G
HIGH STRENGTH = H.S.
HIGHWAY = HWY.
LENGTH OF VERTICAL CURVE = L.V.C.
LEFT = LT.
MEAN SEA LEVEL = M.S.L.
MEAN LOW WATER = M.L.W.
NORTH = N.
ON CENTER = O.C.
PLUS OR MINUS = ±
POINT OF VERTICAL INTERSECTION = P.V.I.
POUNDS = LBS
PRESTRESSED PRECAST CONCRETE = P.P.C.
PRECAST CONCRETE = P.C.
RIGHT = RT.
SPACES
STATION
SYMMETRICAL
T
TOP
TYPICAL
V
VARIES
VERTICAL CURVE
VERTICAL
W
WELDED WIRE FABRIC
WITH
WIDE FLANGE
WORKING POINT = W.P.
= W.F.
= W/
= W.W.F.
= VERT.
= V.C.
= VAR.
= TYP.
= T
= SYM.
= STA.
= SP.
STAY IN PLACE = S.I.P.
U
UNLESS NOTED
OTHERWISE = U.N.O.
SIDEWALK = S.W.
SOUTH = S.
STANDARD = STD.
TOP AND BOTTOM = T&B
TOP OF = T.O.
THICK = THK.
WATER = W
WEST = W.
SQUARE = SQ.
HORIZONTAL = HORIZ.
POLYTETRAFLOUROTHYLENE = PTEF.
PAV'T. = PAVEMENT
GEOSYNTHETIC REINFORCED SOIL = GRS
SELF PROPELLED
= SPMT.MODULAR TRANSPORT
SECTION LETTER
ON SHEET
SHEET DESIGNATION WHERE SECTION IS
FOUND ("-" INDICATES SECTION IS
LOCATED ON THE SAME SHEET)
A
X.X
SECTION MARK
DETAIL NUMBER
ON SHEET
SHEET DESIGNATION WHERE SECTION IS
FOUND ("-" INDICATES SECTION IS
LOCATED ON THE SAME SHEET)
SECTION LETTER
SHEET OF ORIGIN
SHEET DESIGNATION WHERE SECTION IS
ORIGINATED ("-" INDICATES SECTION IS
LOCATED ON THE SAME SHEET
DETAIL NUMBER
SHEET OF ORIGIN
SHEET DESIGNATION WHERE DETAIL IS
ORIGINATED ("-" INDICATES DETAIL IS
LOCATED ON THE SAME SHEET)
GENERAL NOTES
1. ALL CONSTRUCTION INDICATED ON THESE PLANS SHALL BE IN ACCORDANCE WITH:
· THE FEBRUARY 2026 EDITION OF AND SUPPLEMENTS TO THE RHODE ISLAND DEPARTMENT OF
TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (RI
STANDARD SPECIFICATIONS).
· THE AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) LRFD BRIDGE CONSTRUCTION SPECIFICATIONS, 4TH EDITION, WITH 2020, 2022, 2023, 2024 AND 2025 INTERIM
REVISIONS.
· THE SPECIFICATIONS ACCOMPANYING THESE PLANS.
· IN CASE OF CONFLICT BETWEEN THE PLANS, SPECIFICATIONS OR MANUALS LISTED ABOVE, THE
SPECIAL PROVISIONS OF THE SPECIFICATIONS ACCOMPANYING THESE PLANS SHALL GOVERN.
2. DIMENSIONS, STATIONS, AND ELEVATIONS ARE SHOWN TO THE NEAREST ONE-HUNDREDTH OF A FOOT OR ONE-EIGHTH OF AN INCH, EXCEPT STRUCTURAL STEEL DIMENSIONS WHICH ARE TO THE
NEAREST ONE-SIXTEENTH OF AN INCH.
3. ALL ELEVATIONS ARE REFERENCED TO THE NORTH AMERICAN GEODETIC VERTICAL DATUM OF NAVD 88.
4. COORDINATES USED ON THESE PLANS ARE BASED ON THE STATEWIDE COORDINATE SYSTEM, THE
NORTH AMERICAN DATUM OF 1983 (NAD 83).
5. TOPOGRAPHIC CONDITIONS WERE OBTAINED FROM SURVEY BY BL COMPANIES DATED MAY 21, 2020.
6. FOR BENCH MARKS AND TIES SEE HIGHWAY LOCATION PLANS.
7. ANGLES ARE SHOWN TO THE NEAREST SECOND.
8. ALL WORKING POINTS ARE SHOWN AT THE CENTERLINES OF BEARINGS OF ABUTMENTS UNLESS
OTHERWISE NOTED.
9. ALL ABUTMENTS AND WALLS ARE DRAWN LOOKING AT THE EXPOSED FACES.
DESIGN DATA
1. DESIGN SPECIFICATIONS
· THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, 10th EDITION, 2024 INCLUDING ALL INTERIM
REVISIONS TO DATE.
· THE RHODE ISLAND LRFD BRIDGE DESIGN MANUAL 2007 EDITION INCLUDING ALL REVISIONS TO DATE.
· THE FEBRUARY 2024 EDITION OF AND SUPPLEMENTS TO THE RHODE ISLAND DEPARTMENT OF
TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (RI
STANDARD SPECIFICATIONS).
· ALL OTHER APPLICABLE DESIGN SPECIFICATIONS ARE REFERENCED IN SECTION 1 OF THE RHODE
ISLAND LRFD BRIDGE DESIGN MANUAL DATED 2007.
· IN CASE OF CONFLICT, THE RHODE ISLAND LRFD BRIDGE DESIGN MANUAL SHALL GOVERN EXCEPT
FOR SEISMIC DESIGN, FOR WHICH THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS SHALL
GOVERN.
BRIDGE NOTES 1 OF 2
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
STATEWIDE STEEL REPAIRS
AUGUST
AUGUST 2024AUGUST 2026
STRUCTURAL STEEL NOTES
1. FRAMING DIMENSIONS ARE GIVEN ALONG CENTERLINES OF GIRDERS AND ALONG CENTERLINES OF
BEARINGS ON ABUTMENTS.
2. THE SHOPS FABRICATING THE STRUCTURAL STEEL MUST BE CERTIFIED BRIDGE FABRICATOR - ADVANCED
(ABR) IN ACCORDANCE WITH THE AISC QUALITY CERTIFICATION PROGRAM OR EQUIVALENT.
THE SHOPS SHALL ALSO BE CERTIFIED UNDER THE AISC “SOPHISTICATED PAINT ENDORSEMENT P3 (SPE)”
QUALITY PROGRAM OR THE SSPC-QP3 PAINT CERTIFICATION PROGRAM.
THE FABRICATOR MUST SUBMIT PROOF OF CURRENT CERTIFICATION AS SPECIFIED.
3. THE STEEL ERECTOR (FOR STRUCTURAL STEEL REPAIR) FOR THIS PROJECT SHALL BE CERTIFIED FOR CERTIFIED BRIDGE FABRICATOR - SIMPLE (SBR) IN ACCORDANCE WITH THE AISC QUALITY CERTIFICATION PROGRAM. THE ERECTOR OF THE STRUCTURAL STEEL SHALL BE REQUIRED TO SUBMIT PROOF OF CURRENT CERTIFICATION AS SPECIFIED, INCLUDING THE QUALITY CONTROL PLAN AND SAFETY PLAN THAT IS REQUIRED
TO OBTAIN CERTIFICATION.
4. SHOP DRAWINGS FOR ALL FABRICATED STEEL AND FALSEWORK SHALL BE SUBMITTED TO THE ENGINEER IN
SUFFICIENT TIME TO PERMIT CAREFUL CHECKING PRIOR TO FABRICATION.
5. INSPECTION OF WELDS INCLUDING RADIOGRAPHIC TESTING (RT) AND MAGNETIC PARTICLE TESTING (MT) SHALL BE IN ACCORDANCE WITH THE RI STANDARD SPECIFICATIONS AND THE AASHTO/AWS BRIDGE WELDING CODE, EXCEPT THAT THE REMAINING PERCENTAGE OF ALL GROOVE WELDS NOT RT TESTED SHALL BE MT OR
DYE-PENETRANT TESTED.
6. STRUCTURAL STEEL SHAPES AND PLATES SHALL CONFORM TO THE LATEST PROVISIONS OF AASHTO
DESIGNATION M 270 GRADE 50, AS DESIGNATED ON THE PLANS.
7. ALL AASHTO M 270 STRUCTURAL STEEL USED IN GIRDERS (INCLUDING CONNECTION PLATES AND STIFFENERS), SHALL MEET THE ZONE 2 CHARPY V-NOTCH FRACTURE TOUGHNESS TEST REQUIREMENTS AS SPECIFIED IN TABLE C6.6.2.1-1 OF THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS FOR “NONFRACTURE-CRITICAL” COMPONENTS. THE ZONE 2 FRACTURE TOUGHNESS REQUIREMENTS ARE AS
FOLLOWS:
NONFRACTURE-CRITICAL
GRADE 50 OR 50W 15 FT-LBS @ 40°F (UP TO AND INCLUDING 2 INCHES THICK)
GRADE 50 OR 50W 20 FT-LBS @ 40°F (FROM 2 INCH THICK UP TO AND INCLUDING 4 INCHES THICK)
SAMPLING AND TESTING PROCEDURES SHALL BE IN ACCORDANCE WITH AASHTO T 243. THE FREQUENCY OF TESTING SHALL BE IN ACCORDANCE WITH THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS.
THE CHARPY V-NOTCH FRACTURE TOUGHNESS TEST REQUIREMENT IS NOT MANDATORY FOR THE
FOLLOWING STEEL COMPONENTS:
· BEARINGS, MASONRY PLATES AND SOLE PLATES
· EXPANSION JOINTS AND MODULAR BRIDGE JOINT SYSTEMS
· DRAINAGE MATERIAL
· RAILINGS
· FOUNDATION H-PILES AND PIPE PILES
· SUPPORT OF EXCAVATION COMPONENTS
8. WELDING SHALL BE IN ACCORDANCE WITH THE LATEST BRIDGE WELDING CODE AASHTO/AWS D1.5
(INCLUDING ALL INTERIMS TO DATE) AND APPLICABLE SUPPLEMENTAL AWS PUBLICATIONS.
9. ALL HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM F3125, GRADE A325, AND THEY SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 824 OF THE RI STANDARD SPECIFICATIONS. ALL HIGH STRENGTH BOLTS, NUTS AND WASHERS SHALL BE MECHANICALLY GALVANIZED IN ACCORDANCE WITH ASTM B695, CLASS 50.
10. WASHERS MEETING ASTM F436 ARE TO BE USED OVER ALL HOLES THAT ARE MORE THAN 1/16” IN DIAMETER
GREATER THAN THE BOLT DIAMETER AND UNDER ALL PARTS TURNED DURING ASSEMBLY.
11. WELDING ELECTRODES SHALL HAVE THE SAME CORROSION RESISTANCE AS THE BASE METAL AND SHALL BE
FREE OF MOISTURE AT THE TIME OF USE.
12. WELDING OF ATTACHMENTS TO GIRDER FLANGES OR WEBS FOR CONSTRUCTION PURPOSES IS NOT
PERMITTED EXCEPT WHEN APPROVED BY THE ENGINEER.
13. ALL FILLET WELDS SHALL BE IN ACCORDANCE WITH THE BRIDGE WELDING CODE AASHTO/AWS D1.5 TABLE 2.1
(¼” MINIMUM).
BRIDGE NOTES 2 OF 2
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
UTILITY NOTES:
1. CONSTRUCTION EQUIPMENT OR PERSONNEL SHALL FOLLOW OSHA REGULATION IN
REGARDS TO MINIMUM CLEARANCE TO ENERGIZED OVERHEAD LINES.
2. UNDERGROUND UTILITY LINES MAY BE IN CONFLICT WITH REQUIRED TEMPORARY OR
PERMANENT CONSTRUCTION, OR THE EQUIPMENT NECESSARYTO PERFORM THIS
REQUIRED CONSTRUCTION. DEPENDING UPON THE CONTRACTOR'S METHODS OF
CONSTRUCTION, THESE UTILITIES MAY NEED TO BE RELOCATED FOR PORTIONS OF THE
CONSTRUCTION PERIOD AND THEN MOVED BACK TO PERMANENT LOCATIONS WHICH MAY
BE OTHER THAN CURRENT LOCATIONS.
3. BOTH FEDERAL AND STATE LAW (RI. GENERAL LAW 39-1.2) REQUIRE NOTIFICATION OF
APPROPRIATE UTILITY COMPANIES BEFORE DIGGING, TRENCHING, BLASTING,
DEMOLISHING, BORING, BACK FILLING, GRADING, LANDSCAPING, OR OTHER EARTH MOVING
OPERATIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY ALL UTILITY
COMPANIES (INCLUDING THROUGH THE “DIG SAFE” PROGRAM) TO ENSURE THAT ALL
UTILITIES, BOTH UNDERGROUND AND OVERHEAD, HAVE BEEN MARKED BEFORE
COMMENCEMENT OF SUCH WORK. CONTRACTOR SHOULD UNDERSTAND THAT NOT ALL
UTILITIES SUBSCRIBE TO THE “DIG SAFE” PROGRAM. ANY DAMAGE TO EXISTING UTILITIES
MARKED IN THE FIELD, OR AS A RESULT OF FAILING TO CONTACT THE APPROPRIATE
UTILITY COMPANIES, SHALL BE REPAIRED OR REPLACED (AS DEEMED APPROPRIATE BY
THE STATE AND/OR THE IMPACTED UTILITY COMPANY AT NO ADDITIONAL COST TO THE
STATE).
4. DIG SAFE SHALL BE CALLED AT LEAST 72 HOURS PRIOR TO STARTING THE WORK TO
VERIFY LOCATIONS OF EXISTING UTILITIES.
STATEWIDE STEEL REPAIRS
STEEL REPAIR GENERAL NOTES:
1. ALL DIMENSIONS AND DETAILS SHOWN FOR THE EXISTING STRUCTURES HAVE BEEN
OBTAINED FROM RECORD DRAWINGS AND ARE NOT GUARANTEED. THE CONTRACTOR
SHALL DETERMINE AND ESTABLISH ALL DIMENSIONS AND DETAILS NECESSARY FOR
COMPLETION OF ALL WORK BY FIELD MEASUREMENTS AND SURVEY. ANY DISCREPANCIES
REQUIRING MODIFICATIONS TO THE STEEL REPAIR DETAILS SHALL BE BROUGHT TO THE
ATTENTION OF THE ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
ADEQUACY THEREOF, AND ANY MATERIALS ORDERED PRIOR TO SHOP DRAWING
APPROVAL SHALL BE AT THE CONTRACTOR'S OWN RISK.
2. ALL EXISTING STRUCTURAL STEEL SHALL REMAIN UNLESS OTHERWISE NOTED. REMOVAL
OF MATERIAL OR DISCONNECTION OF MEMBERS SHALL NOT BE PERMITTED WITHOUT
EXPRESS WRITTEN APPROVAL OF THE ENGINEER.
3. THE LIMITS OF THE PROPOSED REPAIRS ARE BASED ON THE LATEST INSPECTION REPORTS.
UPON BLASTING AND CLEANING OF THE EXISTING STEEL, THE CONTRACTOR IS
RESPONSIBLE FOR DETERMINING AND MARKING THE LIMITS OF DETERIORATION TO BE
REPAIRED. THESE LIMITS SHALL BE REVIEWED AND APPROVED BY THE ENGINEER PRIOR
TO DEVELOPMENT OF SHOP DRAWINGS FOR PROPOSED STEEL REPAIRS.
4. THE CONTRACTOR SHALL PRE-FIT REPAIR PLATES/ANGLES IN PLACE TO ENSURE NO
CONFLICTS PRIOR TO APPLICATION OF EPOXY PASTE. PLATES SHALL THEN BE
REINSTALLED OVER PASTE AND FIT SNUG TIGHT. FINAL TIGHTENING SHALL BE PERFORMED
AFTER PAST IS FULLY SET.
5. THE CONTRACTOR SHALL SCHEDULE THE WORK SUCH THAT NO HOLES ARE DRILLED UNTIL
ALL REQUIRED REPAIR PLATES/ANGLES ARE ON SITE AND HAVE BEEN PRE-FIT INTO PLACE.
INSTALLATION OF REPAIR MATERIALS SHALL BE COMPLETED IMMEDIATELY AND WITHOUT
INTERRUPTION AFTER HOLES HAVE BEEN DRILLED.
6. EPOXY PASTE (RIDOT APPROVED) FOR STEEL REPAIRS SHALL BE APPLIED TO
DETERIORATED SURFACES AND VOIDS BEHIND THE BENT PLATE RADIUS. NEW PLATES
SHALL BE FIT FLUSH AND TIGHT AGAINST THE EXISTING ELEMENTS AND BOLTS SHALL BE
SNUG TIGHTENED IN PLACE PRIOR TO THE SETTING OF THE EPOXY PASTE. THE PASTE
SHALL BE APPLIED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S LATEST WRITTEN
INSTRUCTIONS.
PAINTING STRUCTURAL STEEL NOTES:
1. NEW STRUCTURAL STEEL SHALL BE PREPARED AND PRIMED IN THE SHOP IN
ACCORDANCE WITH SECTION 825 OF THE RI STANDARD SPECIFICATIONS.
2. CLEAN AND PREPARE ALL DETERIORATED SURFACES TO SSPC-SP5 LEVEL
REQUIREMENTS OR BETTER TO PROVIDE PROPER CONTACT SURFACE FOR THE NEW
REPAIR ELEMENTS. CLEANED AREA SHALL BE THE LIMITS OF THE REPAIR CONTACT
AREA PLUS 6" ALL AROUND.
3. APPLY AN APPROVED PRIMER TO THE CLEANED SURFACE AREA.
4. THE FINAL TOP COAT AND COLOR SHALL MATCH THE EXISTING AND BE APPROVED
BY RIDOT.
5. ANY COMPONENT NOT DESIGNATED TO BE REPAINTED SHALL BE ADEQUATELY
PROTECTED FROM CLEANING OPERATION.
6. THE WORK ASSOCIATED WITH SETTING UP, MAINTAINING AND REMOVING THE
CONTAINMENT SYSTEM FOR THE SURFACE PREPARATION OF THE EXISTING
STRUCTURAL STEEL, MUST BE CONDUCTED IN ACCORDANCE WITH THE PROPOSED
MAINTENANCE AND PROTECTION OF TRAFFIC PLANS AND THE TIME RESTRICTION
SPECIFIED IN THE CONTRACT DOCUMENTS.
7. ANY DAMAGE RESULTING FROM CONTRACTOR'S CLEANING OPERATIONS, SHALL BE
REPAIRED BY THE CONTRACTOR TO THE SATISFACTION OF THE ENGINEER AT NO
ADDITIONAL COST TO THE STATE.
8. WHEN ACCESSING THE SUPERSTRUCTURE FROM ABOVE GROUND, THE
CONTRACTOR IS RESPONSIBLE FOR MAINTAINING PROPER CLEARANCES OVER THE
ROADWAYS. TEMPORARY PROTECTIVE SHIELDING IS REQUIRED WHEN WORKING
ABOVE ROADWAYS.
SPECIAL NOTES TO CONTRACTOR REGARDING AMTRAK:
1. THE CONTRACTOR SHALL BE ESPECIALLY AWARE THAT INFRASTRUCTURE FOR
ELECTRIFICATION OF THE RAILROAD IS IN PLACE AND IS ENERGIZED.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONDUCTING ALL NECESSARY
COORDINATION WITH AMTRAK PRIOR TO AND DURING ALL CONSTRUCTION ACTIVITIES.
3. AMTRAK SPECIFICATIONS REGARDING BONDING, GROUNDING, SHIELDING AND FOR
WORKING OVER AROUND AND WITHIN AMTRAK R.O.W. ARE CONTAINED IN THE
APPENDICES OF THE CS-PAGES OF THE CONTRACT DOCUMENTS. THE CONTRACTOR
SHALL CONDUCT A THOROUGH REVIEW OF THESE SPECIFICATIONS PRIOR TO
COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES AND SHALL SATISFY ALL AMTRAK
REQUIREMENTS AS DIRECTED BY AMTRAK AND/OR THE ENGINEER. THESE AMTRAK
SPECIFICATIONS INCLUDE THE FOLLOWING.
A. AMTRAK'S EP3014 ENGINEERING PRACTICE SECTION 01141A "MAINTENANCE AND
PROTECTION OF RAILROAD TRAFFIC DURING CONTRACTOR OPERATIONS"
B. AMTRAK’S EP3014 ENGINEERING PRACTICE, SECTION 01142A "SUBMISSION
DOCUMENTATION REQUIRED FOR AMTRAK REVIEW AND APPROVAL OF PLANS FOR
BRIDGE ERECTION, DEMOLITION AND OTHER CRANE/HOISTING OPERATIONS OVER
RAILROAD RIGHT-OF-WAY".
C. AMTRAK’S EP3014 ENGINEERING PRACTICE, SECTION 01520A "REQUIREMENTS FOR
TEMPORARY PROTECTION SHIELDS FOR DEMOLITION AND CONSTRUCTION OF
OVERHEAD BRIDGES AND OTHER STRUCTURES".
D. AMTRAK'S EP3016 ENGINEERING PRACTICE "STORM WATER DRAINAGE AND
DISCHARGE FROM ADJACENT PROPERTY ONTO AMTRAK RIGHT-OF-WAY AND
SPECIFICATION NO. 150" STORMWATER MANAGEMENT POLICY.
E. AMTRAK'S PROTECTIVE BARRIERS AND DEBRIS SHIELDS STANDARD DRAWINGS
ET-1446-D AND ET-1447-D.
4. BEFORE ANY WORK IS COMMENCED, COORDINATE WITH AMTRAK REGARDING
REQUIREMENTS OF TRACK AND/OR POWER OUTAGES FOLLOWING ALL STANDARD
PROCEDURES AND SAFETY RULES. SITE SPECIFIC SAFETY WORK PLAN (SSSWP) TO BE
SUBMITTED FOR APPROVAL PRIOR TO COMMENCING ANY WORK.
5. ANY WORK TO BE PERFORMED WITHIN 15 FEET OF THE OVERHEAD WIRES MUST BE
DONE UNDER THE PROTECTION OF AN AMTRAK ELECTRIC TRACTION CLASS "A"
EMPLOYEE.
6. WHENEVER WORK IS PERFORMED IN THE VICINITY OF THE ELECTRIFIED TRACKS
AND/OR HIGH VOLTAGE WIRES. PARTICULAR CARE MUST BE EXERCISED AND
RAILROAD'S REQUIREMENTS REGARDING CLEARANCE TO BE MAINTAINED BETWEEN
EQUIPMENT AND TRACKS AND/OR ENERGIZED WIRES. THE CONTRACTOR MUST
SUPPLY AN ADEQUATE LENGTH OF GROUNDING CABLE 4/0 COPPER WITH APPROVED
CLAMPS) FOR EACH PIECE OF EQUIPMENT WORKING NEAR OR ADJACENT TO ANY
OVERHEAD WIRE (SEE AMTRAK SPECIFICATION 16064).
7. ALL UNDERGROUND UTILITIES, CABLE, AND FACILITIES MUST BE LOCATED AND
PROTECTED BEFORE ANY EXCAVATING, DRILLING, BORING/DIRECTIONAL DRILLING,
GROUND PENETRATING ACTIVITIES OR CONSTRUCTION TAKES PLACE. THIS INCLUDES
RAILROAD AND COMMERCIAL UTILITIES, CABLES, DUCT LINES AND FACILITIES. THESE
ACTIVITIES WILL NOT BE PERFORMED IN CLOSE PROXIMITY TO THE AMTRAK DUCT
LINES UNLESS MONITORED BY ON-SITE AMTRAK COMMUNICATIONS AND SIGNAL (C&S)
DEPARTMENT PERSONNEL. HAND DIGGING MAY BE REQUIRED, AS DIRECTED BY
AMTRAK THROUGH THE ON-SITE AMTRAK C&S SUPPORT PERSONNEL. AMTRAK
MAINTAINS THE RIGHT TO ACCESS ALL EXISTING CABLES AND CONDUITS
THROUGHOUT CONSTRUCTION. AMTRAK ALSO RESERVES THE RIGHT TO UPGRADE
AND INSTALL NEW CABLES AND CONDUITS IN THE AFFECTED AREA. THE "ONE-CALL"
PROCESS MUST BE FOLLOWED. BE AWARE THAT AMTRAK IS NOT A PART OF THE
ONE-CALL PROCESS; CONTACT AMTRAK ENGINEERING TO HAVE ALL AMTRAK
UNDERGROUND UTILITIES AND ASSETS LOCATED. PRECAUTIONS MUST BE TAKEN TO
PREVENT ANY INTERRUPTION TO AMTRAK'S OPERATION.
8. SIGNAL PREVIEW MUST NOT BE OBSTRUCTED. CONSULTANTS PERFORMING WORK FOR
AMTRAK OR ON AMTRAK PROPERTY MUST SHOW THAT THERE IS ADEQUATE SIGNAL
PREVIEW. IN ADDITION, ALL TEMPORARY STRUCTURES, FORMWORK, EQUIPMENT, ETC.
MUST COMPLY WITH THIS DURING CONSTRUCTION.
9. A MINIMUM SIGNAL PREVIEW DISTANCE SHALL NOT BE LESS THAN 1500 FEET. SIGNAL
PREVIEW IS MEASURED FROM A POINT 13 FEET ABOVE THE TOP OF RAIL, AT A MINIMUM
OF 1500 FEET FROM THE TOP SIGNAL HEAD (“A” HEAD) OF THE SIGNAL THE TRAIN IS
APPROACHING. CONSULTANTS PERFORMING WORK FOR AMTRAK ON AMTRAK
PROPERTY SHALL PROVIDE A DRAWING SHOWING THAT THERE IS ADEQUATE SIGNAL
PREVIEW. THIS DRAWING MUST BE IN THE FINAL DESIGN. ALL TEMPORARY
STRUCTURES, FORMWORK, EQUIPMENT, ETC. MUST NOT OBSTRUCT SIGNAL PREVIEW
DURING CONSTRUCTION.
10. IF WORK INVOLVES HEAVY TRUCKS, EQUIPMENT, OR MACHINERY ALONG THE
RIGHT-OF-WAY, DUCT LINES AND PULL BOXES SHALL BE INSPECTED TO INSURE THEY
CAN WITHHOLD THE APPROPRIATE WEIGHT. REFER TO TIER TABLE DOCUMENT.
11. RAILS MUST BE PROTECTED AGAINST DEBRIS, RUST, SAND, METAL SHAVINGS OR
OTHER MATERIAL THAT CAN INTERFERE WITH THE PROPER SHUNTING SENSITIVITY OF
THE TRACK CIRCUIT.
19'-91 8"
9'-4 3 16 "
1'-9"88'-9 9 16 "
11'-1 1 4 "
9'-0"
7 SPACES @
11'-1 3
16 " = 77'-8 5 16 "
6 SPACES @ 23'-41
2" = 140'-3"
6'-7"
187'-0"
8'-117
8" 9'-0" 9'-0" 18 SPACES @ 7'-91
2" = 140'-3" 6'-7"6'-71 8"
SP
AC
ES
-5 1 2"
7' -8
BEAM A
BEAM B
BEAM C
BEAM D
BEAM E
BEAM F
BEAM G
BEAM H
BEAM I
D -7
G
D -7
G
D -7
G
D -7
G
D -7
G
D -7
G
D -7
G
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -5
D -8
E
D -8
E
D -7
E
D -7
E
D -7
ED-6
D-6G
D-4
D-4
D-4
D-4
D-4
D-4A
D-4
W.P. 3
49°38'27" (TYP.)
K-1
14'-0"
N55°-19'-56"E
C BRG. ABUT. C (EXP.)L
C PIER (FIX.)L
D -7
E
D -7
E
C BRG. ABUT. D (EXP.)L
D -8
E
D -8
E
D -7
E
D -8
E
D -8
E
D -8
E
D -8
E
D -7
E
D -8
E
D -8
E
D -8
E
D -8
E
D -8
E
D -8
E D-6
D-6G
D-4
D-4
D-4
D-4
D-4
D-4
D -8
E
D -8
E
N55°-19'-56"E
N55°-19'-56"E
C FRANCIS ST.
N05°-41'-29"E
W.P. 4 W.P. 5 L
26'-117 8"
EDGE OF DECK
C 9-5"Ø ELECTRICAL DUCTSL
C 8"Ø GAS PIPEL
FACE OF
CURB
FACE OF
CURB
EDGE OF DECK
REPAIR TYPE 1
REPAIR TYPE 1
9'-0" 1'-3"26'-0"26'-0"7'-3"
8 SPACES @ 8'-5 12" = 67'-8" (SQUARE) 1'-0"
8" CONCRETE DECK
C FRANCIS ST.L
W36x170 (TYP.)
6"x6" GRANITE
CURB (TYP.)
EAST PARAPET
1'-9"C 8" GAS PIPE
W/ 12" STEEL PIPE SLEEVE
LC 9 - 5"Ø
ELECTRICAL
DUCTS
L
7" (TYP.) 2"Ø R.S.
CONDUIT
FRANCIS ST NORTH BRIDGE OVER AMTRAK
FRAMING PLAN
BR. NO. 086501 FRANCIS STREET NORTH BRIDGE OVER AMTRAK
FRAMING PLAN
SCALE: 18" = 1'-0"
TRANSVERSE SECTION
SCALE: 14" = 1'-0"
(LOOKING NORTH)
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
PROVIDENCE
NOTES:
1. THE EXISTING PLANS ARE TAKEN FROM THE 1979 PLAN SET,
"RHODE ISLAND DEPARTMENT OF TRANSPORTATION, DIVISION OF
PUBLIC WORKS, CAPITAL CENTER PROJECT CONTRACT NO. 1,
GASPEE STREET FRANCIS STREET PROVIDENCE , RI.
DESCRIPTION OF PROPOSED WORK ON BRIDGE No. 086501:
1. STEEL BEAM REPAIRS AT THE LOCATIONS SHOWN ON THE PLANS.
C EXIST. W36 BEAML
EXIST. W36x170
EXIST 8"x 12"
COVER PLATE
EXIST. BOT. FLANGE
EXIST 8"x 12"
COVER PLATE
A
EXIST. BOT. FLANGE
SEE NOTE 1SEE NOTE 1
FRANCIS STREET NORTH BRIDGE OVER AMTRAK
STEEL REPAIRS - TYPE 1
BR. NO. 086501 FRANCIS STREET NORTH BRIDGE OVER AMTRAK
SCALE: 11
2" = 1'-0"
SECTION A
BEAM - ELEVATION
SCALE: 11
2" = 1'-0"
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
PROVIDENCE
STEEL REPAIR NOTES:
1. REMOVE THE EXISTING CRACKED FILLET WELD BY GRINDING OR AIR CARBON ARC
GOUGING FOLLOWED BY GRINDING TO SOUND METAL.
2. REMOVE ALL EVIDENCE OF CRACKING AS VERIFIED BY MAGNETIC PARTICLE
TESTING (MT).
3. GRIND THE GROOVE SMOOTH PRIOR TO WELDING.
4. REWELD USING LOW-HYDROGEN ELECTRODES CONFORMING TO AWS D1.5
BRIDGE WELDING CODE.
5. DEPOSIT WELD METAL IN ACCORDANCE WITH THE CONTRACTOR'S APPROVED
WELDING PROCEDURE SPECIFICATION (WPS).
6. MATCH THE EXISTING WELD SIZE UNLESS OTHERWISE NOTED.
7. GRIND WELD STARTS AND STOPS SMOOTH.
8. UPON COMPLETION, PERFORM MT OF THE COMPLETED REPAIR WELD.
9. REPAIR ANY DEFECTS REVEALED BY INSPECTION AT NO ADDITIONAL COST.
10. PROTECT ADJACENT STEEL FROM ARC STRIKES, GOUGES, AND EXCESSIVE HEAT.
NOTES:
1. REMOVE CRACKED PORTION OF EXISTING FILLET WELD AS SHOWN. REPAIR
LENGTH SHALL EXTEND A MINIMUM OF 2 IN. BEYOND EACH END OF THE
INDICATED CRACK OR AS DETERMINED BY NDT.
SP
AC
ES
'-5
1'
-4
31'-99 16"
31'-9"
31'-9"
26'-107 8"
27'-113 8" 32'-113
4" 32'-113 4" 33'-05
16"
ALONG TANGENT
W.P.
STA. 235+98.84
W.P.
STA. 235+65.65
STA. 235+32.62 B PRIMARY
RTE. 37 EASTBOUND
STA. 131+75.87 C JEFFERSON
BLVD. EXT.
W.P.
STA. 234+99.69
W.P.
STA. 234+71.87
L
L
TANGENT BASELINE
STA. 235+32.62
S59°-07'-28"E
B PRIMARY RTE. 37
EASTBOUND R=3000'
L 6' -6
" 14'-5" 12'-93
8" 3 SPACES @ 16'-63
4" = 49'-81 4" 14'-93
16"
36WF135 36WF150 BEAM - A 36WF135
15'-213 16"17'-01
2"
30WF99
DO
DO
36WF135
DO
DO
DO
DO
C
BR
G
. (EXP.)
L
SPAN 1 SPAN 2 SPAN 3
ABU
TM
EN
T A
C
JEFFER
SO
N
BLVD
. EXT.
N 15°11'19"E
L C
BR
G
. (EXP.)
LABU
TM
EN
T B
36WF150 BEAM - I
DO BEAM - B
BEAM - C
BEAM - D
BEAM - E
BEAM - F
BEAM - G
BEAM - H
DO
DO
DO
DO
DO
DO
74°18'47" (TYP.)
PROFILE
GRADE LINE
30WF99
DO
DO
DO
DO
DO
DO
36WF135
DD
DD
DD
CC
CC
CC
DD
DD
DD
DB
DB
DB
CA
CA
CA
DB
DB
DB
C
BR
G
. (FIXED
L
C
BR
G
. (EXP.)
L
C
PIER
L
C
BR
G
. (FIXED
L
C
BR
G
. (FIXED
L
C
PIER
L
3"
(TYP.)
16" 811
16" 811 16" 811
16"
REPAIR TYPE 4
REPAIR TYPE 4
REPAIR TYPE 4
REPAIR TYPE 4
REPAIR TYPE 4
REPAIR TYPE 4
REPAIR TYPE 4
REPAIR TYPE 2
REPAIR TYPE 3
REPAIR TYPE 3
REPAIR TYPE 3
REPAIR TYPE 8REPAIR TYPE 5
REPAIR TYPE 9REPAIR TYPE 7
REPAIR TYPE 6
REPAIR TYPE 7 REPAIR TYPE 10
REPAIR TYPE 1
REPAIR TYPE 4
REPAIR TYPE 9
REPAIR TYPE 3
REPAIR TYPE 3
24'-0"2'-0"1'-0"
2' -8
VARIES 8 SPACES @ 6'-5" = 51'-4"
2" CONCRETE DECK
B PRIMARY RTE. 37L
27'-0"
BM A
10" (TYP.)
57'-0"
1'-6" (TYP.)
ALUMINUM BRIDGE
RAILING
2.7%
3" ASPHALTIC CONCRETE PAVEMENT
OVER WATERPROOF MEMBRANE
HALF SECTION AT MID-SPAN HALF SECTION AT MID-SPAN
BM I
2'-0" 1'-0"
BEAM (TYP.)C18 (TYP.)
6"x12" GRANITE
CURB (TYP.)
VARIES
2"Ø GALV. STEEL
LIGHTING CONDUIT
C12 (TYP.)
3'-0"
P.G.L.
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
FRAMING PLAN
SCALE: 18" = 1'-0"
TRANSVERSE SECTION
SCALE: 14" = 1'-0"
(LOOKING EASTERLY)
LEGEND:
EXPANSION BEARING "TYPE A" WITH PINTLE.
EXPANSION BEARING "TYPE B" WITH PINTLE.
FIXED BEARING "TYPE C" WITH PINTLE.
FIXED BEARING "TYPE D" WITHOUT PINTLE.
STEEL REPAIR LOCATION
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
WARWICK
A
B
C
D
JEFFERSON BOULEVARD SOUTH BRIDGE
FRAMING PLAN
NOTES:
1. THE EXISTING PLANS ARE TAKEN FROM THE 1964 PLAN SET,
"RHODE ISLAND DEPARTMENT OF TRANSPORTATION, DIVISION OF
PUBLIC ROADS AND BRIDGES, PRIMARY ROUTE 37 FROM FUTURE
JEFFERSON BOULEVARD TO HILLSGROVE RAILROAD SMITH
WARWICK , RI., AND 2012 REPAIRS TO JEFFERSON BOULEVARD -
SOUTH BRIDGE NO. 634.
DESCRIPTION OF PROPOSED WORK ON BRIDGE No. 063401:
8" BENT PLATE A
8" REPAIR PLATE
C BRG.L
EXIST. BEARING
FACE OF EXIST.
ABUTMENT A STEM
4"
1'-0"
4" 4" 6" 2" 2"
4"
2"
2"
2"
12 SPACES @ 5" = 5'-0"
8"±5"
5" 5"
4"
D
A
EXIST. BEAM 9
36 WF 135
B
C
8" REPAIR PLATE
8" FILL PLATE
8" BENT PLATE A
(TYP.)
5" 5"
5" 4"
4" 4"
2"
8"
2"
8" (TYP.)
2" (TYP.)
8" BENT PLATE C
16"±
8"±
8"
8" BENT PLATE A
8" BENT PLATE B
C BRG.L
12 SPACES @ 5" = 5'-0"
1'-0" 4"
4"
2"
2"
2"
16"± 5"
5" 5"
4"
2" 6" 4" 4"
2"
2"
EXIST. BEAM 9
36 WF 135
8" FILL PLATE
8" BENT PLATE A
8" BENT PLATE C
FACE OF EXIST.
ABUTMENT A STEM
A
B
C
D
EXIST. BEARING
GRIND EXIST. CONN. PLATE WELD AS
REQ'D TO FIT BENT PLATE (TYP.)
EXIST.
BEARING
FACE OF EXIST.
ABUTMENT A STEM
CUT BENT PLATE TO
MATCH EXIST. FLANGE
C BRG.L
FACE OF EXIST.
ABUTMENT A BACKWALL
4" 1'-0" 12 SPACES @ 5" = 5'-0"
2" (TYP.)
2" (TYP.)
C BEAM 1L
8" BENT PLATE A
8" BENT PLATE A
8" BENT PLATE B3
8" BENT PLATE A
8" BENT PLATE C
8" REPAIR PLATE
8" FILL PLATE
8" FILL PLATE
2"
TIGHT FIT
8" BENT PLATE B (N.S.)
8" BENT PLATE C (F.S.)
2"
8"
2"
5" 5"
5" 4"
4" 4"
2" (TYP.)
8" (TYP.)
8"Ø BOLT THROUGH
CENTER OF EXIST. C12
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
4" 4"
5" 41 8"
CLIP BENT PLATES TO
AVOID BEAM FILLET
2"
8" BENT PLATE A (TYP.)
8" REPAIR PLATE
8" FILL PLATE
EXIST. C12
2"
2"
4" 21 2"
8" BENT PLATE A (TYP.)
2"
8"
2"
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
3. ALL BOLTS TO BE 7/8" DIAMETER A 325 BOLTS UNLESS
NOTED OTHERWISE.
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION D
SCALE: 11
2" = 1'-0"
SECTION A
SCALE: 11
2" = 1'-0"
SECTION B
NORTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION C
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
WARWICK
JEFFERSON BOULEVARD SOUTH BRIDGE
STEEL REPAIRS - TYPE 1
EXIST. BEAM 1
36 WF 135
5" 6" 5" 2" 2"
8"± 4"
4" 4"
4" 4"3
8" BENT PLATE A
4"
2"
2"
2" 10 SPACES @ 5" = 4'-2"
11" 2"
C PIER 1L
C BRG.L C BRG.L
2"
8" BENT PLATE B
8" FILL PLATE
8" BENT PLATE A
8" BENT PLATE C
EXIST. BEAM 10
36 WF 150
FACE OF EXIST.
PIER 1 (TYP.)
EXIST. BEARING
(TYP.)
A
B
C
D
4"
8" REPAIR PLATE
8" FILL PLATE
8" BENT PLATE A
(TYP.)
4" 4"
4" 4"
4" 4"
2"
8"
2"
8" (TYP.)
2" (TYP.)
8" BENT PLATE C
8"±
8"
4"
EXIST. BEAM 1
36 WF 135
C PIER 1L
C BRG.L C BRG.L
5" 6" 5" 2" 2"
8"±4"
4" 4"
4" 4"
4" 4"
2"
8" REPAIR PLATE
8" BENT PLATE A
FACE OF EXIST.
PIER 1 (TYP.)
EXIST. BEARING
(TYP.)
EXIST. BEAM 10
36 WF 150
A
B
D C BEAM 1L
C BEAM 10L
C PIER 1L
C BRG.LC BRG.L
10 SPACES @ 5" = 4'-2"
2"
2"
11" 2"
8" BENT PLATE A
8" BENT PLATE A
FACE OF EXIST.
PIER 1 (TYP.)
8" BENT PLATE B
EXIST.
BEARING
(TYP.)
8" BENT PLATE C
8" REPAIR PLATE
8" BENT PLATE A
8" FILL PLATE
TIGHT FIT
8" BENT PLATE B (N.S.)
8" BENT PLATE C (F.S.)
2"
8"
2"
4" 4"
4" 4"
2" (TYP.)
8" (TYP.)
8"Ø BOLT THROUGH
CENTER OF EXIST. C12
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
4" 4"
5" 41 8"
CLIP BENT PLATES TO
AVOID BEAM FILLET
2"
8" BENT PLATE A (TYP.)
8" REPAIR PLATE
8" FILL PLATE
EXIST. C12
2"4" 4"
4"
2"
4" 21 2"
8" BENT PLATE A (TYP.)
2"
8"
2"
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION D
SCALE: 11
2" = 1'-0"
SECTION A
SCALE: 11
2" = 1'-0"
SECTION B
NORTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION C
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
WARWICK
JEFFERSON BOULEVARD SOUTH BRIDGE
STEEL REPAIRS - TYPE 2
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
3. ALL BOLTS TO BE 7/8" DIAMETER A 325 BOLTS UNLESS
NOTED OTHERWISE.
4"
2"
2"
2"
4" 5"
41 2" 41 2"3"±
2" 4" 6" 5"
2"
4" 11"
C PIER 1L
C BRG.L C BRG.L
EXIST. BEAM 2
36 WF 99
B -
A
C
8" BENT
PLATE C
8" BENT
PLATE A
8" FILL PLATE
8" BENT
PLATE B
2"
2"
2"
8" (TYP.)
2" (TYP.)
4" 4"
5" 41 2"
41 2" 215 16"
8" BENT PLATE A
(TYP.)
8" BENT PLATE C
(TYP.)
8" FILL PLATE
(TYP.)
EXIST. C12
(TYP.)
2"
2"
2"
8" BENT PLATE A
(TYP.)
8" (TYP.)
2" (TYP.)
TIGHT FIT (TYP.)
CLIP BENT PLATES TO AVOID
BEAM FILLET (TYP.)
41 8" 5"
2"
8"Ø BOLT THROUGH CENTER
OF EXIST. C12 (TYP.)
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
2" (TYP.)
8" BENT PLATE C
(F.S.) (TYP.)
8" BENT PLATE B
(N.S.) (TYP.)
8" FILL PLATE
C PIER 1L
C BRG.LC BRG.L
FACE OF EXIST.
PIER 1 (TYP.)
EXIST. BEARING (TYP.)
C BEAML
8" BENT PLATE A
(TYP.) (BOTH SIDES)
8" FILL PLATE
11"
4"
2"2"
8" FILL PLATE (TYP.)
8" BENT PLATE C (TYP.)
(BOTH SIDES)
8" BENT PLATE B (TYP.)
(BOTH SIDES)
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
(SOUTH ELEVATION SHOWN, NORTH ELEVATION SIMILAR)
SCALE: 11
2" = 1'-0"
SECTION C
SCALE: 11
2" = 1'-0"
SECTION A
SCALE: 11
2" = 1'-0"
SECTION B
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
WARWICK
JEFFERSON BOULEVARD SOUTH BRIDGE
STEEL REPAIRS - TYPE 3
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
2"
2"
4"11"
EXIST. BEAM 11-17
36 WF 150
4" 4"
4" 4"
4" 4" 21
2"±
8" BENT PLATE B
8" FILL PLATE
2"
8" BENT PLATE A
2"
2"
5"
C PIER 1L
C BRG.L C BRG.L
6" 4" 2"
8" BENT PLATE C
FACE OF EXIST.
PIER 1 (TYP.)
EXIST. BEARING
(TYP.)
A
B
C
4"
2"
2"
4" 11"
EXIST. BEAM 11-17
36 WF 150
4" 4"
4" 4"
4" 4"21
2"±
8" BENT PLATE B
8" FILL PLATE
2"
8" BENT PLATE A
2"
2"
5"
C PIER 1L
C BRG.LC BRG.L
6"4" 2"
8" BENT PLATE C
FACE OF EXIST.
PIER 1 (TYP.)
EXIST. BEARING
(TYP.)
A
B
C
2"
8"
2"
4" 4"
4" 4"
4" 4"
4"
2" (TYP.)
8" (TYP.)
2"±
1"
8" BENT PLATE C
8" FILL PLATE
8" BENT PLATE A
(TYP.)
4" 4"
5" 41 8"
2"
2"
EXIST. C12
8" BENT PLATE B
(N.S.) (TYP.)
2" (TYP.)
8" (TYP.)
2"±
1"
8"Ø BOLT THROUGH
CENTER OF EXIST. C12
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
8" FILL PLATE
8" BENT PLATE C
(F.S.) (TYP.)
2"
8"
2"
TIGHT FIT (TYP.)
CLIP BENT PLATES TO AVOID
BEAM FILLET (TYP.)
C PIER 1L
C BRG.LC BRG.L
FACE OF EXIST.
PIER 1 (TYP.)
EXIST. BEARING (TYP.)
8" FILL PLATE (TYP.)
8" BENT PLATE C (TYP.)
(BOTH SIDES)
8" BENT PLATE B (TYP.)
(BOTH SIDES)
8" BENT PLATE A
(TYP.) (BOTH SIDES)
4"
11"
2"11 2"
C BEAML
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION C
SCALE: 11
2" = 1'-0"
SECTION A
SCALE: 11
2" = 1'-0"
SECTION B
NORTH ELEVATION
SCALE: 11
2" = 1'-0"
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
WARWICK
JEFFERSON BOULEVARD SOUTH BRIDGE
STEEL REPAIRS - TYPE 4
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
10 SPACES @ 5" = 4'-2"
2" (TYP.) 2"
11"
8" BENT PLATE A
4"
2"
2"
2"
8" BENT PLATE B
8" FILL PLATEEXIST. BEAM 10
36 WF 150
4" 4"
4" 4"
4"17 16"±
8" BENT PLATE C
8" BENT PLATE A
4"
5"6"5" 2"
2"
A
C PIER 2L
C BRG.L C BRG.L
B
C
D
EXIST. BEAM 10
36 WF 150
8" BENT PLATE A
2"
2"
2"
10 SPACES @ 5" = 4'-2"
2"2"
11"
4" 4"
4" 4"
4" 4"
2"
1"2" 5" 6" 5"
2"
8" REPAIR PLATE
C PIER 2L
C BRG.L C BRG.L
D
C PIER 2L
C BRG.LC BRG.L
EXIST. BEARING (TYP.)
10 SPACES @ 5" = 4'-2" 11"
2"2" (TYP.)
2" (TYP.)
8" BENT PLATE A
8" BENT PLATE A
8" REPAIR PLATE
8" BENT PLATE B
8" FILL PLATE
8" BENT PLATE C
C BEAML
2" 21
2"
8"
8" (TYP.)
2" (TYP.)
4" 4"
4" 4"
4" 4"
4"
16"±
2"±
8" BENT PLATE A
(TYP.)
8" BENT PLATE C
8" REPAIR PLATE
8" FILL PLATE
8"Ø BOLT THROUGH
CENTER OF EXIST. C12
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
2"
2"
8"
2"
2" (TYP.)
8" (TYP.)
CLIP BENT PLATES TO
AVOID BEAM FILLET
8" BENT PLATE A (TYP.)
4" 4"
4" 4"
4" 4"
4"
41 8"
4" 4"
5"
2"
EXIST. C12
8" BENT PLATE C (F.S.)
8" REPAIR PLATE
8" FILL PLATE
2" 21
2"
8"
2" (TYP.)
4"
8" BENT PLATE A
(TYP.)
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION D
SCALE: 11
2" = 1'-0"
SECTION A
SCALE: 11
2" = 1'-0"
SECTION B
NORTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION C
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
WARWICK
JEFFERSON BOULEVARD SOUTH BRIDGE
STEEL REPAIRS - TYPE 5
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
C PIER 2L
C BRG.L C BRG.L
2" 4" 6" 5"
2"
2"
2"
2"
4" 11"
4" 4"
4" 4"
4" 4"
4"17 16"±
8" BENT PLATE C
8" BENT PLATE A
8" BENT PLATE B
8" FILL PLATE
8" BENT PLATE A
A
B
C
EXIST. BEAM 13
36 WF 150
C PIER 2L
C BRG.LC BRG.L
4" 11"
2"2" (TYP.)
2" (TYP.)
8" BENT PLATE B
(TYP.) (BOTH SIDES)
8" BENT PLATE A
(TYP.) (BOTH SIDES)
8" BENT PLATE C
(TYP.) (BOTH SIDES)
C BEAML
2" 21
2"
8"
8" (TYP.)
2" (TYP.)
4" 4"
4" 4"
4" 4"
4"
16"±
8" BENT PLATE A
(TYP.)
8" BENT PLATE C
8" FILL PLATE
8"Ø BOLT THROUGH
CENTER OF EXIST. C12
(TYP.)
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
2"
2"
8"
2"
2" (TYP.)
8" (TYP.)
CLIP BENT PLATES TO
AVOID BEAM FILLET (TYP.)
8" BENT PLATE A (TYP.)
4" 4"
4" 4"
4" 4"
4"
41 8" 4"
4" 5"
2"
EXIST. C12 (TYP.)
8" BENT PLATE C (F.S.) (TYP.)
8" FILL PLATE
8" BENT PLATE B (N.S.)
(TYP.)
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
(SOUTH ELEVATION SHOWN, NORTH ELEVATION SIMILAR)
SCALE: 11
2" = 1'-0"
SECTION C
SCALE: 11
2" = 1'-0"
SECTION A
- SCALE: 11
2" = 1'-0"
SECTION B
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
WARWICK
JEFFERSON BOULEVARD SOUTH BRIDGE
STEEL REPAIRS - TYPE 6
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
2" 4" 6" 5"
2"
2"
2"
2"
4" 11"
4"
4" 4" 4"
4" 4"
4"17 16"±
8" BENT PLATE C
8" BENT PLATE A
8" BENT PLATE B
8" FILL PLATE
8" BENT PLATE A
A
B
D
EXIST. BEAM 14/15
36 WF 150
6 SPACES @ 5" = 2'-6"
C
C PIER 2L
C BRG.LC BRG.L
4" 11"
2"
8" BENT PLATE B
(TYP.) (BOTH SIDES)
8" BENT PLATE A
(TYP.) (BOTH SIDES)
8" BENT PLATE C
(TYP.) (BOTH SIDES)
C BEAML
2" (TYP.)
6 SPACES @ 5" = 2'-6"
2" (TYP.)
2" 21
2"
8"
8" (TYP.)
2" (TYP.)
4" 4"
4" 4"
4" 4"
4"
16"±
8" BENT PLATE A
(TYP.)
8" BENT PLATE C
8" FILL PLATE
8"Ø BOLT THROUGH
CENTER OF EXIST. C12
(TYP.)
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
2"
2"
8"
2"
2" (TYP.)
8" (TYP.)
CLIP BENT PLATES TO
AVOID BEAM FILLET (TYP.)
8" BENT PLATE A (TYP.)
4" 4"
4" 4"
4" 4"
4"
41 8" 4"
4" 5"
2"
EXIST. C12 (TYP.)
8" BENT PLATE C (F.S.) (TYP.)
8" FILL PLATE
8" BENT PLATE B (N.S.)
(TYP.)
2" 21
2"
8"
2" (TYP.)
4"
8" BENT PLATE A
(TYP.)
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
(SOUTH ELEVATION SHOWN, NORTH ELEVATION SIMILAR)
SCALE: 11
2" = 1'-0"
SECTION D
SCALE: 11
2" = 1'-0"
SECTION A
SCALE: 11
2" = 1'-0"
SECTION B
SCALE: 11
2" = 1'-0"
SECTION C
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
WARWICK
JEFFERSON BOULEVARD SOUTH BRIDGE
STEEL REPAIRS - TYPE 7
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
5 SPACES @ 4" = 1'-8"
2" (TYP.)1'-0"
2"
8" BENT PLATE A
8" BENT PLATE B
4" 4"
4" 4"
4" 4"
8" FILL PLATE
4"
2"
2"
2" 6" 6" 4"
2"
16"±
8" BENT PLATE C
8" BENT PLATE A
2"
EXIST. BEAM 19
36 WF 135
A
B
D
B
C PIER 2L
C BRG.L C BRG.L
2" 2" 4" 6" 6"
4" 4"
4" 4"
4"4"
4"
2"
2"
2"
5 SPACES @ 4" = 1'-8" 1'-0"
2"
8" BENT PLATE A
8" REPAIR PLATE
EXIST. BEAM 19
36 WF 135
A
B
D
C
C PIER 2L
C BRG.LC BRG.L
EXIST. BEARING (TYP.)
1'-0" 5 SPACES @ 4" = 1'-8"
2" (TYP.)2"
2" (TYP.)
8" BENT PLATE A
8" BENT PLATE A
8" REPAIR PLATE
8" FILL PLATE
8" BENT PLATE B
8" BENT PLATE C
C BEAML
8" REPAIR PLATE
8" FILL PLATE
8" BENT PLATE A
(TYP.)
4" 4"
4" 4"
4" 4"
2"
8"
2"
8" (TYP.)
2" (TYP.)
8" BENT PLATE C
8"±
8"
4"
TIGHT FIT
8" BENT PLATE B (N.S.)
8" BENT PLATE C (F.S.)
2"
8"
2"
4" 4"
4" 4"
2" (TYP.)
8" (TYP.)
8"Ø BOLT THROUGH
CENTER OF EXIST. C12
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
4" 4"
5" 41 8"
CLIP BENT PLATES TO
AVOID BEAM FILLET
2"
8" BENT PLATE A (TYP.)
8" REPAIR PLATE
8" FILL PLATE
EXIST. C12
2"4" 4"
4"
2"
4" 21 2"
8" BENT PLATE A (TYP.)
2"
8"
2"
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION D
SCALE: 11
2" = 1'-0"
SECTION A
SCALE: 11
2" = 1'-0"
SECTION B
NORTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION C
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
WARWICK
JEFFERSON BOULEVARD SOUTH BRIDGE
STEEL REPAIRS - TYPE 8
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
EXIST. BEAM 23
36 WF 99
4"
2"
2"
2"±41 2"
41 2" 5" 4"
2"
C PIER 2L
C BRG.L C BRG.L
5" 6" 4"
7 SPACES @ 5" = 2'-10"
11"
2"
8" BENT PLATE A
8" BENT PLATE B
8" FILL PLATE
8" BENT PLATE C
8" BENT PLATE A
A
B
C
D
C PIER 2L
C BRG.LC BRG.L
FACE OF EXIST.
PIER 2 (TYP.)
EXIST. BEARING (TYP.)
C BEAML
2" 2" (TYP.)
2" (TYP.)
11" 7 SPACES @ 5" = 2'-10"
8" BENT PLATE A
(TYP.) (BOTH SIDES)
8" BENT PLATE B
(TYP.) (BOTH SIDES)
8" BENT PLATE C
(TYP.) (BOTH SIDES)
8" FILL PLATE
8" FILL PLATE
2"
2"
2"
8" (TYP.)
2" (TYP.)
4" 4"
5" 41 2"
41 2" 11 2"±
8" BENT PLATE A
(TYP.)
8" BENT PLATE C
(TYP.)
8" FILL PLATE
(TYP.)
EXIST. C12
(TYP.)
2"
2"
2"
8" BENT PLATE A
(TYP.)
8" (TYP.)
2" (TYP.)
TIGHT FIT (TYP.)
CLIP BENT PLATES TO AVOID
BEAM FILLET (TYP.)
41 8" 5"
2"
8"Ø BOLT THROUGH CENTER
OF EXIST. C12 (TYP.)
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
2" (TYP.)
8" BENT PLATE C
(F.S.) (TYP.)
8" BENT PLATE B
(N.S.) (TYP.)
8" FILL PLATE
2"
2"
2"
8" (TYP.)
2" (TYP.)
4"
8" BENT PLATE A
(TYP.)
2" (TYP.)
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
(SOUTH ELEVATION SHOWN, NORTH ELEVATION SIMILAR)
SCALE: 11
2" = 1'-0"
SECTION D
SCALE: 11
2" = 1'-0"
SECTION A
SCALE: 11
2" = 1'-0"
SECTION B
SCALE: 11
2" = 1'-0"
SECTION C
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
WARWICK
JEFFERSON BOULEVARD SOUTH BRIDGE
STEEL REPAIRS - TYPE 9
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
C BRG.L
2"
2"
4" 5"
41 2" 41 2"11
2"±
1'-0"
4" 7" 5"
4"
2" 21 2"
EXIST. BEAM 24
36 WF 99
8" BENT PLATE C
8" BENT PLATE A
8" BENT PLATE B
8" FILL PLATE
2"
2"
B -
A
C
FACE OF EXIST.
ABUTMENT B STEM
C BRG.L
FACE OF EXIST.
ABUTMENT B STEM FACE OF EXIST.
ABUTMENT B BACKWALL
EXIST. BEARING
C BEAML
2"
2" (TYP.)
2" (TYP.)
1'-0"4"
8" BENT PLATE A (TYP.)
(BOTH SIDES)
8" BENT PLATE B (TYP.)
(BOTH SIDES)
8" BENT PLATE C (TYP.)
(BOTH SIDES)
8" FILL PLATE
8" FILL PLATE
2"
2"
2"
8" (TYP.)
2" (TYP.)
4" 4"
5" 41 2"
41 2" 11 2"
8" BENT PLATE A
(TYP.)
8" BENT PLATE C
(TYP.)
8" FILL PLATE
(TYP.)
EXIST. C12
(TYP.)
2"
2"
2"
8" BENT PLATE A
(TYP.)
8" (TYP.)
2" (TYP.)
TIGHT FIT (TYP.)
CLIP BENT PLATES TO AVOID
BEAM FILLET (TYP.)
41 8" 5"
2"
8"Ø BOLT THROUGH CENTER
OF EXIST. C12 (TYP.)
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
2" (TYP.)
8" BENT PLATE C
(F.S.) (TYP.)
8" BENT PLATE B
(N.S.) (TYP.)
8" FILL PLATE
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
(SOUTH ELEVATION SHOWN, NORTH ELEVATION SIMILAR)
SCALE: 11
2" = 1'-0"
SECTION C
SCALE: 11
2" = 1'-0"
SECTION A
SCALE: 11
2" = 1'-0"
SECTION B
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 063401 JEFFERSON BOULEVARD - SOUTH BRIDGE
WARWICK
JEFFERSON BOULEVARD SOUTH BRIDGE
STEEL REPAIRS - TYPE 10
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
124'-87 16"
SPAN 1
124'-87
16"
SPAN 2
250'-111 2"
B RT. 44
WESTBOUND
L
B RT. 44
WESTBOUND
L
B RT. 44
EASTBOUND
L
C BRG. WEST ABUT. (EXP.)L C BRG. (FIXED)C BRG. (EXP.)L L C BRG. EAST ABUT. (EXP.)L
GIRDER A
15°38'27"
74°21'33"
5 SPAC
ES @
8'-7 13 16 " = 43'-3 3
16 "5
SP
AC
ES
'-4
1'
-8
4'-01 2"
4'-01 2"
4'-23 8"
5 SPAC
ES @
8'-7 13 16 " = 43'-3 3
16 "
C PIERL
SP
AC
ES
'-4
1'
-8
EXIST. INTERMEDIATE
UTILITY SUPPORT (TYP.)
EXIST. DIAPHRAGM
(TYP.)
COMM
DUCT BANK
L
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 1
4'-23 8"
GIRDER C
GIRDER D
GIRDER E
GIRDER F
GIRDER G
GIRDER H
GIRDER J
GIRDER I
GIRDER K
GIRDER L
GIRDER A
GIRDER B
GIRDER C
GIRDER D
GIRDER E
GIRDER F
GIRDER G
GIRDER H
GIRDER J
GIRDER I
GIRDER K
GIRDER L
GIRDER B
REPAIR TYPE 2
C EXIST. 12"
GAS PIPE
1'-91 4"
PARAPET
12'-0"
LANE
12'-0"
LANE
5 SPACES @ 8'-4" = 41'-8" 4'-01
2"
2" CONCRETE DECK
B WESTBOUNDL
EXIST. PLATE
GIRDER
3" DIA. CONDUIT
2%
17'-0"
AUXILIARY LANE
P.G.L.
2%
5'-9"
SHLDR.
4'-4"
B ROUTE 44L ROUTE 44 WESTBOUND
12'-0"
LANE
12'-0"
LANE
2" CONCRETE DECK 2%
17'-0"
AUXILIARY LANE
P.G.L.
2%
4'-6"
SHLDR.
1'-61
4" BARRIER (TYP.)B EASTBOUNDL
4'-01
2" 5 SPACES @ 8'-4" = 41'-8"
1'-91 4"
PARAPET
SNOW FENCE
3" DIA. CONDUIT
2"
3'-1"
4" OPEN JOINT
ROUTE 44 WESTBOUND
99'-6"
(OUT TO OUT)
C EXIST. 12"
GAS PIPE
L
EXIST. 3" HMA
(TYP.)
CONST.JT.
COMM DUCT BANK
RIDOT FIBER OPTIC
COMM. LINE
BR. NO. 074101 US 44 PUTNAM PIKE OVER I-295
FRAMING PLAN
SCALE: 1" = 10'-0"
TRANSVERSE SECTION
SCALE: 14" = 1'-0"
(LOOKING WEST)
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
SMITHFIELD,
US 44 PUTNAM PIKE OVER I-295
FRAMING PLAN
NOTES:
1. THE EXISTING PLANS ARE TAKEN FROM THE 1971 PLAN SET,
"RHODE ISLAND DEPARTMENT OF TRANSPORTATION, DIVISION OF
PUBLIC WORKS, PUTNAM PIKE BRIDGE NO. 741, SMITHFIELD , RI.,
AND BRIDGE GROUP 35 US 44 PUTNAM PIKE 2021 PLAN SET.
DESCRIPTION OF PROPOSED WORK ON BRIDGE No. 074101:
8x8x1
2 BENT
PLATE (TYP.)
2"
(TYP.)
2"
(TYP.)
1'-101 2"
2" (TYP.)
3" (TYP.)
C BRG.L
8x8x1
2 BENT
PLATE (TYP.)
2"
(TYP.)
2"
(TYP.)
1'-101 2"
2" (TYP.)
3" (TYP.)
C BRG.L
16"
8"
4"
(TYP.)
2"
(TYP.)
3" (TYP.)
8x8x1
2 BENT
PLATE (TYP.)
2 - L3" x 4" x 38"
REPLACE IN KIND
TEMPORARILY SUPPORT UTILITY
DURING CONSTRUCTION
TYP.
US 44 PUTNAM PIKE OVER I-295
STEEL REPAIRS - TYPE 1 AND TYPE 2
SCALE: 11
2" = 1'-0"
SECTION A
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
BR. NO. 074101 US44 PUTNAM PIKE OVER I-295
SMITHFIELD,
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
A
UTILITY BRACING DETAIL
SCALE: 3 4" = 1'-0"
NORTH ELEVATION
SCALE: 11
2" = 1'-0"
REPAIR TYPE 2
REPAIR TYPE 1
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. SEE SHEET 6 FOR PAINTING REQUIREMENTS.
17°-06'-02.1"33 '-6
SP
AC
ES
'-4
6'
-0
C BRG. WEST ABUT. (EXP.)L
N 08°-25'-00"W
C BRG. EAST ABUT. (FIX.)L
92'-1011
16" (SKEW)
88'-913
32" (SQUARE)
B SMITH ST.
N81°-18'-57"E
STA. 2+50.382
L
BM A W36 x 194
23'-25 8"23'-223
32" 23'-25 8" 23'-223
32"
23'-0"
C 9 x 13.4
D -5
C 9 x 13.4
C 9 x 13.4
C 9 x 13.4
D -5
D -5
D -5
D -5
12'-0"
23'-0"12'-0" 23'-0"23'-0" 12'-0"
D -3
D -3
D -3
D -3
D -3
D -3
D -1
D -3
D -3
D -3
D -3
D -3
D -3
D -1
D -4
D -2
D -2
D -4
D -2
D -2
D -1
D -1
D -1
12'-0"
D -1
D -1
12'-0" 12'-0"
D -1
D -1
D -4
D -2
D -2
D -4
D -2
D -2
D -4
D -2
D -2
D -4
D -2
D -2
'-6
69'-0 5 8 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
BM B
BM C
BM D W36 x 194
BM E
BM F
BM G
BM H
BM I DO
BM J W36 x 194
DO
DO
DO
DO
DO
DO
3' -2
4'
-2
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
L4 x 4x 1 4 "
D -3 D
-3
D -2
D -2
D -2
STA. 3+43.273
C 24" WATER PIPEL
C 9 - 5"
ELECTRIC
CONDUITS
L
12" GAS PIPE
C 4 - 4" TELEPHONE
CONDUITS
L
N 08°-25'-00"W
REPAIR TYPE 1
REPAIR TYPE 2
REPAIR TYPE 2
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 1
REPAIR TYPE 2
REPAIR TYPE 2
REPAIR TYPE 2
12'-0"12'-0"7'-0"
SIDEWALK
1'-0"
2' -4
1'-6" 9 SPACES @ 7'-4" = 66'-0" (SQUARE)
2" CONCRETE DECK
C SMITH ST. R.R. BRIDGEL
W36x192 (TYP.)
6"x6" GRANITE
CURB (TYP.)
14'-0"15'-0" 7'-0"
SIDEWALK
1'-0"
2' -4
1'-6"
MC 18 x 42.7MC 18 x 42.7 MC 18 x 42.7MC 18 x 42.7
L4x4x1 4"
4" TELEPHONE
CONDUITS
MC 18 x 42.7
BM A BM B BM C BM D BM E BM F BM G BM H BM I BM J
MC 18 x 42.7MC 18 x 42.7
1% 1%
7" (TYP.)
3%
L4x4x1 4"
9 - 5" ELECTRICAL
CONDUITS
24" WATER PIPE IN
36" STEEL JACKET
SOUTH SIDE NORTH SIDE
3%
6" (TYP.)
12" GAS IN
16" JACKET
TYP. INTERMEDIATE
DIAPHRAGMS FOR
INTERIOR BAYS
53'-0"
BR. NO. 092801 SMITH STREET R.R. BRIDGE
FRAMING PLAN
SCALE: 18" = 1'-0"
TRANSVERSE SECTION
SCALE: 14" = 1'-0"
(LOOKING WEST)
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
PROVIDENCE,
SMITH STREET R.R. BRIDGE
FRAMING PLAN
NOTES:
1. THE EXISTING PLANS ARE TAKEN FROM THE 1979 PLAN SET,
"RHODE ISLAND DEPARTMENT OF TRANSPORTATION, DIVISION OF
PUBLIC WORKS, SMITH STREET RAILROAD BRIDGE NO. 928,
PROVIDENCE , RI.
DESCRIPTION OF PROPOSED WORK ON BRIDGE No. 092801:
A
B
C
5"
FW x 3"H HOLE
2" THICK
BENT PLATE
5X5X1
2" BENT
PLATE5X5X1
2" BENT
PLATE B
D
C BRG.L
3"
2"
2"
2"
EXIST. BEAM
FACE OF EXIST.
ABUTMENT A STEM
EXIST.
BEARING
GRIND EXIST. CONN.
PLATE WELD AS REQ'D TO
FIT BENT PLATE (TYP.)
9 SPACES @ 5" = 3'-9"
13x6x1
2" BENT PLATE
(TYP.)
2" FILL PLATE
(TYP.)
2" REPAIR PLATE
(TYP.)
D
2"
5"
C BRG.L
EXIST.
BEARING
FACE OF EXIST.
ABUTMENT A STEM
9 SPACES @ 5" = 3'-9"
A
B
C
3"
2"
2"
EXIST. BEAM
5X5X1
2" BENT
PLATE (TYP.)
FW x 3"H HOLE
FW x 8"H HOLE
TIGHT FIT
8" BENT PLATE B (B.S.)
8" BENT PLATE C (B.S.)
2" (TYP.)
8" (TYP.)
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
CLIP BENT PLATES TO
AVOID BEAM FILLET
8" BENT PLATE A (TYP.)
8" REPAIR PLATE
8" FILL PLATE
EXIST. C (TYP.)
2"
8"
13x6x1
2" BENT PLATE
(TYP.)
8"
5" 11
2"EXIST.BEARING
FACE OF EXIST.
ABUTMENT A STEM
CUT BENT PLATE TO
MATCH EXIST. FLANGE
C BRG.L
FACE OF EXIST.
ABUTMENT A BACKWALL
2" (TYP.)
C BEAML
8" BENT PLATE A
8" BENT PLATE A
8" BENT PLATE B
8" FILL PLATE
SMITH STREET R.R. BRIDGE
STEEL REPAIRS - TYPE 1
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
NORTH ELEVATION
SCALE: 11
2" = 1'-0"
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION D
SCALE: 11
2" = 1'-0"
SECTION A
- SCALE: 11
2" = 1'-0"
SECTION B
SCALE: 11
2" = 1'-0"
SECTION C
BR. NO. 092801 SMITH STREET R.R. BRIDGE
PROVIDENCE,
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. STRUCTURAL STEEL PLATES AND SHAPES SHALL
CONFORM TO THE LATEST PROVISIONS OF ASTM A588
WEATHERING STEEL.
3. ALL BOLTS AND WASHERS TO BE 7/8" DIAMETER A325,
TYPE 3 WEATHERING STEEL BOLTS UNLESS NOTED
OTHERWISE.
A
B
C
FW x 7"H HOLE
2" THICK
BENT PLATE
5X5X1
2" BENT
PLATE5X5X1
2" BENT
PLATE B
E
C BRG.L
3"
2"
2"
2"
EXIST. BEAM
FACE OF EXIST.
ABUTMENT A STEM
EXIST.
BEARING
GRIND EXIST. CONN.
PLATE WELD AS REQ'D TO
FIT BENT PLATE (TYP.)
12 SPACES @ 5" = 5'-0"
13x6x1
2" BENT PLATE
(TYP.)
2" FILL PLATE
(TYP.)
2" WEB PLATE
(TYP.) 2'
-6
8"
D
2"
C BRG.L
EXIST.
BEARING
FACE OF EXIST.
ABUTMENT A STEM
9 SPACES @ 5" = 3'-9"
A
B
C
3"
2"
2"
EXIST. BEAM
FW x 8"H HOLE
5X5X1
2" BENT
PLATE (TYP.)
FW x 3"H HOLE
TIGHT FIT
8" BENT PLATE B (B.S.)
8" BENT PLATE C (B.S.)
2" (TYP.)
8" (TYP.)
8"Ø BOLT THROUGH
EXIST. HOLE (TYP.)
CLIP BENT PLATES TO
AVOID BEAM FILLET
8" BENT PLATE A (TYP.)
8" REPAIR PLATE
8" FILL PLATE
EXIST. C (TYP.)
8"
13x6x1
2" BENT PLATE
(TYP.)
8"
5" 11
2"EXIST.BEARING
FACE OF EXIST.
ABUTMENT A STEM
CUT BENT PLATE TO
MATCH EXIST. FLANGE
C BRG.L
FACE OF EXIST.
ABUTMENT A BACKWALL
2" (TYP.)
C BEAML
8" BENT PLATE A
8" BENT PLATE A
8" BENT PLATE B
8" FILL PLATE
SMITH STREET R.R. BRIDGE
STEEL REPAIRS - TYPE 2
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
NORTH ELEVATION
SCALE: 11
2" = 1'-0"
SOUTH ELEVATION
SCALE: 11
2" = 1'-0"
SCALE: 11
2" = 1'-0"
SECTION E
SCALE: 11
2" = 1'-0"
SECTION A
- SCALE: 11
2" = 1'-0"
SECTION B
SCALE: 11
2" = 1'-0"
SECTION C
BR. NO. 092801 SMITH STREET R.R. BRIDGE
PROVIDENCE,
NOTES:
1. SEE SHEET 5 AND 6 FOR GENERAL NOTES.
2. STRUCTURAL STEEL PLATES AND SHAPES SHALL
CONFORM TO THE LATEST PROVISIONS OF ASTM A588
WEATHERING STEEL.
3. ALL BOLTS AND WASHERS TO BE 7/8" DIAMETER A325,
TYPE 3 WEATHERING STEEL BOLTS UNLESS NOTED
OTHERWISE.
1'-3"
5' -0
'-0
'-0
5'
-0
1'-3"
88'-31 2" 43'-81
8"
89'-45 16" 51'-21
8"
89'-41 4"28'-81
8"
250'-0"
88'-31 2"39'-21
8"
268'-01 16"
C BRG. WEST. ABUT.
(EXP.)
L
C SPRAGUE STREET
ASPHALTIC EXPANSION JOINT
SYSTEM TO BE REMOVED
AND REPLACED IN KIND
SIDEWALK JOINT
FILLER
C PIERL C BRG. EAST. ABUT.
(EXP.)
L
EXIST. BITUMINOUS
SIDEWALK
EXISTING 14'-0"
APPROACH SLAB
EXIST. BITUMINOUS
SIDEWALK
EXIST. BITUMINOUS
SIDEWALK
EXISTING 14'-0"
APPROACH SLAB
SPRAGUE STREET
RI-2
N.B D
RI-2
S.B D
N.E. ENDPOST
S.E. ENDPOSTS.E. ENDPOST
ASPHALTIC EXPANSION JOINT
SYSTEM TO BE REMOVED
AND REPLACED IN KIND
ASPHALTIC EXPANSION JOINT
SYSTEM TO BE REMOVED
AND REPLACED IN KIND
L
14'-0"14'-0"5'-0"
SIDEWALK
2'-9" 5 SPACES @ 7'-0" = 35'-0"
5'-0"
SIDEWALK
1'-3"
2'-9"
C SPRAGUE ST. BRIDGEL
W36 x 245 (TYP.)
BM 3 BM 4BM 2BM 1 BM 5 BM 6
MC18 x 42.7 (TYP.)
40'-6"
EXIST. PEDESTRIAN
CHAIN LINK FENCE (TYP.)
9" (TYP.)
4" CONCRETE DECK
3" ASPHALTIC CONCRETE PAVEMENT
OVER WATERPROOF MEMBRANE
BR. NO. 064401 SPRAGUE STREET BRIDGE
GENERAL PLAN
SCALE: 1" = 10'-0"
TRANSVERSE SECTION
SCALE: 14" = 1'-0"
RHODE ISLAND
DEPARTMENT OF TRANSPORTATION
RHODE ISLAND
RIDOT 2026 STATEWIDE STEEL REPAIRS
VOLUME 1
PORTSMOUTH
SPRAGUE SREET BRIDGE
GENERAL PLAN
NOTES:
1. THE EXISTING PLANS ARE TAKEN FROM THE 1962 PLAN SET,
"RHODE ISLAND DEPARTMENT OF TRANSPORTATION, DIVISION OF
PUBLIC WORKS, SPRAGUE STREET BRIDGE, PORTSMOUTH, RI,
GENERAL PLAN AND 1987 SAFETY IMPROVEMENT PLANS.
DESCRIPTION OF PROPOSED WORK ON BRIDGE NO. 064401:
1. ASPHALT PLUG JOINT REPLACEMENTS AT THE LOCATIONS SHOWN ON
THE PLANS.
1'-6"1'-4"1'-2"
C JOINTL
C BRG.L
R&D EXISTING
ASPHALT JOINT
EXISTING
APPROACH SLAB
EXISTING
BACKWALL
6"6"
C JOINTL
C BRG.L
R&D EXISTING
ASPHALT JOINT
EXIT. PAVEMENT
CUT LINE
C BRG.L
C PIERL
1'-6"1'-4"1'-2"
C JOINTL
C BRG.L
EXISTING
APPROACH SLAB
EXISTING
BACKWALL
6"6"
C BRG.LC BRG.L
C PIERL
EXIT. PAVEMENT
CUT LINE
EXISTING MODIFIED
BITUMINOUS BASE COURSE
10" 10"
1'-8"
NOMINAL
ASPHALTIC JOINT MATERIAL
(SEE RI STANDARD SPECIFICATIONS)
1DETAIL
POLYMER…
This is the start of the file's text. The full file is on GovTribe.