2026 Appendix A Fire Suppression System List.pdf
PDF 118 KB Posted
- Solicitation number
- 1798
About this file
This is a facilities inventory document detailing the fire suppression and detection systems installed across multiple buildings at a federal military installation. The document lists 60+ buildings and structures with comprehensive information on each system's configuration, including building number, location name, sprinkler valve manufacturer, valve location within the facility, system type (wet, dry, pump, or ANSUL/specialized suppression), date the facility was constructed, and the date the fire suppression system was installed.
The systems span multiple manufacturers including Victaulic, Reliable, Firematic, Grinnell, Viking, Rasco, Gemini, Porter, CSC, Tyco, Automatic, Zasco, and ANSUL specialized systems. System types vary from traditional wet and dry sprinkler systems to fire pump installations and specialized suppression systems including ANSUL NOVEC 1230, ANSUL IQ301/IQ318 with VESDA detection, and INERGEN systems. Facilities range in age from 1952 to 2019, with system installation dates spanning from 1954 to 2023, indicating ongoing maintenance and modernization of fire protection infrastructure. The document notes standpipe (STD) designations on several systems and indicates facility locations such as mechanical rooms, basements, stairwells, boiler rooms, server rooms, and garage areas where these systems are positioned.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STD = Standpipe
Building #
Location
Make
Sprinkler Valve Location
Type
Date of Facility
Date System was installed
1102 NC3 Wet 1956 2023 1152 LG Supply Gem South East Corner of Build. Wet 1956 1998 1106 Conference Center Gem Basement Wet 1956 1998 1108 Admin Offices FIRE PUMP Basement PUMP 1954 1998 1108 Admin Offices 3rd Floor Closet Dry 1954 2019 1108 Admin Offices Basement Wet /STD 1954 2019 1109 Admin Offices Basement Wet/STD 1954 1109 Admin Office 3rd Floor Coset Dry 1954 1109 Admin Office FIRE PUMP Basement PUMP 1954 1201 Steam Plant Grinnell Boiler Room Wet 1954 2011 1201 Pump House Grinnell Pump House Wet 1954 1986 1208 Munitions Mx Viking Bathroom Wet 1954 1993 1240 Family Support Rm 602 - Rear Mech Rm Wet 1956 2016 1305 HQ ABG Rasco Mech Room Wet/STD 1984 1984 1305 HQ ABG FIRE PUMP Mech Room PUMP 1984 1984 1425 The Commons Firematic Basement Wet 1954 2002 1427 VOQ Victaulic Basement Wet 1954 2000
1435 SC Info.System & Computer Victaulic Mech Room Wet 1959 2009
1435 SC Info.System & Computer
ANSUL NOVEC
1230 Server Room ANSUL 1959 2012
1445 SF Warehouse Victaulic South East Corner of Build. Wet 2006 2005 1510 Dorm Victaulic Stairwell Wet/STD 1955 2001 1511 Dorm Victaulic Stairwell Wet/STD 1955 2001 1531 Bowling center Shotgun Kitchen Wet 1965 2016 1527 Dorm Mech Room Dry 2019 2019 1527 Dorm Mech Room Wet 2019 2019 1548 Fitness Center Tyco 6” Mech Room Wet 1956 2006 1603 Chapel Victaulic Mech Room Wet 1955 2016 1603 Chapel Victaulic Mech Room Dry/Nitro 1955 2016 1604 PK/JA Porter/Victaulic Mech Room Wet 2010 2009 1607 Elect. Rsch Eng Victaulic Basement Mech Room Wet/STD 1955 2000 1608 Auto Hobby Shop Reliable Garage Wet 1978 1999 1612 Elect Rsch Eng Automatic 1st Floor Mech Room Wet/STD 1981 1980 1614 Phase I Rasco Mech Room Wet 1955 2001 1614 Phase II Reliable Loading Dock Wet 1955 2001 1614 Phase 0 Reliable Near Room 148 Wet 1955 2001 1618 Admin Office Victaulic Mech Room Wet 1964 2014 1624 Elect. Rsch Eng Firematic Mech Room Wet/STD 1987 2008 1630 Elect. Rsch Eng Firematic Mech Room Wet/STD 1990 1987
1642 Motor Pool CSC North Side (@pumps) Wet 1955 1954 1642 Motor Pool CSC South Side Wet 1955 1954
1646 DMATS
ANSUL
IQ318/VESDA 1st floor/basement ANSUL 1953 2012
1646 DMATS Mech Room Wet 1953 2018 1646 DMATS Mech Room Dry 1953 2018 1709 BX AAFES Reliable Zone B – Sprink Room Wet 2002 2001 1712 Offices Garage Wet 2017 1712 Offices Garage Dry 2017 1725 Security Forces Viking Mech Room Wet 1995 1994 1728 Education Center Zasco 4” Hall Closet Wet 1955 1996 1813 BE Storage Shed Viking Mech Room Wet 1952 2002 1813 BE Storage Shed Viking Mech Room Dry 1952 2004 1827 CE Roads & Grounds Victaulic Mech Room Wet 2007 2007 1993 Youth Center Porter Mech Room Wet 1973 2004 1994 Child Care Center Firematic Mech Room Wet 1994 1994 1999 After School Care Reliable Mech Room Dry 1960 2001
Sagamore Hill
Sagamore Hill
IQ301 BFA, VESDA
& INERGEN
Bldg 5
ANSUL
ANSUL
1968 &
File details come from the government source that posted it. Updated .