2026-14260 Virtual Tour.pdf

PDF 6 MB Posted

Attached to
Portland International Airport Terminal and Concourses Wayfinding Signage
Solicitation number
144651
Issued by
Multnomah County, Oregon

About this file

This is a virtual tour document and signage floor plan for the Portland International Airport Terminal and Concourses Wayfinding Signage project in Oregon. The project involves the installation of wayfinding signage throughout multiple concourses (C, D, and E) and terminal areas, with detailed floor plans showing signage locations across multiple enplaning sectors (00, 01, 02, 03, 40, 52, 53, 70, 71, 72, and 73). The document includes panoramic photo locations accessible through interactive links, allowing virtual navigation of the airport spaces where signage will be installed. The drawings are prepared at a scale of 1/8" = 1'-0" and include numerous keynotes detailing specific demolition and installation requirements for existing signs, including soffit-supported wall mount signs, flag mount signs, ceiling-supported signs, overhead truss-supported signs, and illuminated area of refuge signs. Multiple areas are identified for sign removal, with requirements to patch and repair finishes after completion.

The document references structural and electrical drawings for additional information on sign installation and demolition procedures. Sign locations are organized by sector and correspond to specific terminal spaces including holdrooms, restrooms, circulation areas, retail concessions, food and beverage outlets, and employee facilities. Each floor plan includes a sign legend and notes indicating that detailed specifications are provided in separate sign family sheets (references G9.051 through G9.052). The enhanced drawings are provided for reference only and include links to panoramic photos that allow interactive viewing of the terminal environments. The project was drawn by B. Stevens, designed by K. Fry, and checked by Jay Ostlund, with document dated August 2026.

View the file

Other files

File Type Posted
PDX 2026-512 (134) G2.103.pdf PDF
PDX 2026-512 (155) G2.172.pdf PDF
PDX 2026-512 (128) G2.071.pdf PDF
PDX 2026-512 (146) G2.151.pdf PDF
PDX 2026-512 (47) E1.273.pdf PDF
PDX 2026-512 (71) E2.753.pdf PDF
PDX 2026-512 (147) G2.152.pdf PDF
PDX 2026-512 (102) G0.001.pdf PDF
PDX 2026-512 (42) E0.300.pdf PDF
PDX 2026-512 (85) E9.004.pdf PDF
PDX 2026-512 (17) S2.253.pdf PDF
PDX 2026-512 (98) T4.001.pdf PDF
PDX 2026-512 (193) G2.342.pdf PDF
PDX 2026-512 (132) G2.101.pdf PDF
PDX 2026-512 (76) E5.001.pdf PDF
PDX 2026-512 (169) G2.242.pdf PDF
PDX 2026-512 (242) G9.137.pdf PDF
PDX 2026-512 (172) G2.252.pdf PDF
PDX 2026-512 (80) E8.003.pdf PDF
PDX 2026-512 (97) T2.253.pdf PDF
PDX 2026-512 (159) G2.202.pdf PDF
PDX 2026-512 (12) S2.200.pdf PDF
PDX 2026-512 (217) G9.112.pdf PDF
PDX 2026-512 (96) T2.252.pdf PDF
PDX 2026-512 (8) S0.003.pdf PDF
PDX 2026-512 (77) E7.001.pdf PDF
PDX 2026-512 (215) G9.110.pdf PDF
PDX 2026-512 (126) G2.063.pdf PDF
PDX 2026-512 (130) G2.073.pdf PDF
PDX 2026-512 (91) T1.253.pdf PDF
PDX 2026-512 (151) G2.162.pdf PDF
PDX 2026-512 (27) S2.353.pdf PDF
PDX 2026-512 (35) S6.111.pdf PDF
PDX 2026-512 (79) E8.002.pdf PDF
PDX 2026-512 (212) G9.107.pdf PDF
PDX 2026-512 (93) T2.153.pdf PDF
PDX 2026-512 (6) S0.001.pdf PDF
PDX 2026-512 (44) E1.240.pdf PDF
PDX 2026-512 (53) E1.753.pdf PDF
PDX 2026-512 (28) S2.370.pdf PDF
PDX 2026-512 (149) G2.160.pdf PDF
PDX 2026-512 (86) E9.005.pdf PDF
PDX 2026-512 (92) T2.100.pdf PDF
PDX 2026-512 (192) G2.341.pdf PDF
PDX 2026-512 (145) G2.143.pdf PDF
PDX 2026-512 (207) G9.102.pdf PDF
PDX 2026-512 (104) G0.003.pdf PDF
PDX 2026-512 (240) G9.135.pdf PDF
PDX 2026-512 (119) G2.040.pdf PDF
PDX 2026-512 (185) G2.303.pdf PDF
Show 40 more

Latest 50 of 247 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BOMA: 2219 SF

2-ADA

HOLDROOM D5

D21099

BOMA: 2254 SF

2-ADA

HOLDROOM D4

D21004

BOMA: 376 SF

GPM

STAIRS

D2038

BOMA: 684 SF

GTO

WOMEN

D2223

BOMA: 128 SF

PMB

JANITOR

D2221

GPM

D2219

BOMA: 272 SF

PMB

NETWORK

D2217 BOMA: 1361 SF

CFO

F & B

D2216

BOMA: 1129 SF

CRO

RETAIL

D2205

BOMA: 1123 SF

CFO

F & B

D2208

BOMA: 1034 SF

CFO

F & B

D2200

BOMA: 1667 SF

2-ADA

HOLDROOM D4

D2040

BOMA: 102 SF

PMB

SHAFT

XD2010

BOMA: 173 SF

GPM

STAIRS TO MEZZANINE

D2228

BOMA: 3272 SF

CFO

F & B

D2212

BOMA: 2579 SF

2-ADA

HOLDROOM D5

D2036

BOMA: 689 SF

CRO

RETAIL

D2039

BOMA: 375 SF

GPM

STAIRS

D2038BOMA: 97 SF

CRS

STORAGE

D21685

BOMA: 29 SF

PMB

ELEC SHAFT

D2237

BOMA: 348 SF

GPM

STAIRS

D2230

BOMA: 302 SF

GPA

CORRIDOR

D2226

BOMA: 31 SF

PMB

SHAFT

BOMA: 108 SF

GPM

ELEV D3

D2224

BOMA: 17 SF

2-APL

SCID MONITOR

D2226A

BOMA: 2176 SF

2-ADA

HOLDROOM

D20793

BOMA: 559 SF

GTO

MEN

D20826

BOMA: 563 SF

GTO

MEN

D20822

BOMA: 562 SF

GTO

WOMEN

D20728

BOMA: 1763 SF

GPA

CONCOURSE BY-PASS VESTIBULE

D2034

BOMA: 98 SF

GTO

LACTATION

D20920

BOMA: 120 SF

GTO

FAMILY RESTROOM

D20916

BOMA: 219 SF

CPS

PET RELIEF

D20912

BOMA: 556 SF

GTO

MEN

D20848

BOMA: 555 SF

GTO

MEN

D20846

BOMA: 556 SF

GTO

WOMEN

D20748

D8D9D10D11D12D13D14D15D16

DE

DD

DC

DB

DA

TT

TS

WM2 001

FM3 023

FM4 001

CM2 020

GN1 022

PB1 026

PB1 025

GN1 021

K10 008

MW1 002

ST2 072

ST2 073

AE2 006

ST4 005

AE3 015

ST2 074

ST4 007

AE2 007

AE3 016

B A

VM4 012

RR10 014 RR10 015

RR10 012 RR10 013

M A

T C

H L

IN

E

G

.2

M A

T C

H L

IN

E

G

.2

RR10 071

IF1 021

IF1 020

IF1 016

IF1 018

IF1 019

RN1 001

FD6 018

FD7 005

FD6 019

IF1 017

IFW 007

RR1 022

RR1 021

ST2 041

RN1 020

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:22:47 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

CONCOURSE D - ENPLANING - SECTOR 00 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.200

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 00 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

1 DEMOLISH EXISTING

SOFFIT-SUPPORTED WALL MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES AS

REQUIRED AFTER NEW WORK IS

COMPLETE. SEE STRUCTURAL AND

ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

2 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

3 REMOVE ILLUMINATED AREA OF

REFUGE SIGN. PATCH AND REPAIR

AS REQUIRED

4 REMOVE EMERGENCY

COMMUNICATION SIGN. PATCH AND

REPAIR AS REQUIRED

KEYNOTES:

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

CLICK ON DOT TO OPEN PHOTO - DRAG PHOTO SCREEN TO "LOOK AROUND"

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/103/attachments/105&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/104/attachments/106&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/105/attachments/107&autoLoad=true

BOMA: 868 SF

BLUE STAR DOUGHNUTS

LLC

CFO

F & B

D20412

CRO

RETAIL

T2TR91

BOMA: 637 SF

CFO

F & B

D20410

BOMA: 984 SF

CFO

F & B

D20128

BOMA: 987 SF

CFO

COFFEE

D20126

BOMA: 1492 SF

CFO

F & B

D20151

BOMA: 973 SF

CRO

RETAIL

T2TR73

BOMA: 604 SF

CFO

SEATING

D20489

BOMA: 1087 SF

GPS

SEATING

D20357

BOMA: 825 SF

GPA

CIRCULATION

D20389

BOMA: 607 SF

GPS

SEATING

D20257

BOMA: 477 SF

CFO

CONCESSION SEATING

D20457

BOMA: 876 SF

CFO

CONCESSION SEATING

D20157

BOMA: 1239 SF

GPA

CIRCULATION

D20289

BOMA: 483 SF

GPS

SEATING

D20189

BOMA: 482 SF

2-ADA

HOLDROOM E1 RAMP

E20199

BOMA: 515 SF

2-APL

COMMON LOUNGE LOBBY

T2TT62

BOMA: 77 SF

GPM

ELEV T42

T2TT63

BOMA: 67 SF

PMB

SHAFT

TSTT68

BOMA: 214 SF

GPM

STAIR 03

T2TT61

BOMA: 191 SF

STIAR 02

T2TU60

BOMA: 7275 SF

GPA

CIRCULATION

D20150

BOMA: 378 SF

POP

SHARED STORAGE

D20681 BOMA: 157 SF

PMB

SHAFT

DS0689

BOMA: 143 SF

GPM

ELEV DF2

D20685

BOMA: 374 SF

GPA

CORRIDOR

D20665

BOMA: 18 SF

PMB

SHAFT

DS0669

BOMA: 83 SF

GPM

STAIR 00

D20675

BOMA: 565 SF

GTO

WOMEN

D20724

BOMA: 335 SF

GPA

CORRIDOR

D20622

BOMA: 170 SF

PMB

JANITOR

D20618

BOMA: 379 SF

POP

STORAGE

D206618

BOMA: 87 SF

PMB

IRRIGATION CONTROL

D20614

BOMA: 43 SF

PMB

SHAFT

DS0610

BOMA: 94 SF

STAIRS

BOMA: 40 SF

PMB

SHAFT

DS0618

BOMA: 228 SF

GPM

EXTERIOR STAIR 01

D20695

BOMA: 6935 SF

GPA

CIRCULATION

T2TR80

BOMA: 601 SF

GPM

STAIR 06

T2TQ95

BOMA: 114 SF

PMB

JANITOR

T2TR68

BOMA: 1424 SF

GTO

RESTROOM ALL-USER

T2TR69

BOMA: 467 SF

SSE

EMPLOYEE SCREENING EXIT

T2TR65

BOMA: 56 SF

SSE

STORAGE

T2TR63

BOMA: 71 SF

SSE

PRIVATE INTERVIEW

T2TR62

BOMA: 4883 SF

GPA

EXIT PLAZA

T2TS63

BOMA: 508 SF

CRO

RETAIL

T2TS61

BOMA: 699 SF

GPS

GARDEN SEATING

T2TS65

BOMA: 535 SF

GPA

SEATING

T2TS72

BOMA: 282 SF

GPA

CIRCULATION

T2TR71

BOMA: 302 SF

GPA

CIRCULATION

T2TS70

BOMA: 1086 SF

GPA

CIRCULATION

T2TQ70

BOMA: 614 SF

GPS

SEATING

D20406

BOMA: 630 SF

GPA

CIRCULATION

T2TR85

BOMA: 172 SF

PMB

JANITOR

D2646

BOMA: 560 SF

GTO

WOMEN

D20746

T19 T18 T17 D1D2D3D4D5D6D7

DE

DD

DC

DB

DA

TT

TS

FM3 022

ST2 087

ST2 086

K10 014

AE3 026

RR10 029

CM2 007

B

CM2 006

B

CM2 005

B

CM2D 002

B

A

CMC3 002

B

A

FMD2 005

A

M A

T C

H L

IN

E

G

.2

2M

A T

C H

L

IN

E

G

.2

STAIR 6

T2TQ95

RR10 072

FD6 020

MATCHLINE - G2.211

ST2 047

RN1 019

A BB A

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:22:58 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

TERMINAL - ENPLANING - SECTOR 01 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.201

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 01 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

1 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

2 DEMOLISH EXISTING

SOFFIT-SUPPORTED WALL MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS. PATCH AND REPAIR

FINISHES AS REQUIRED. SEE

STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION.

KEYNOTES:

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

CLICK ON DOT TO OPEN PHOTO - DRAG PHOTO SCREEN TO "LOOK AROUND"

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/122/attachments/124&autoLoad=true

BOMA: 1268 SF

CRO

NEWSTAND

T2TS24

BOMA: 596 SF

CRO

CONCESSIONS

T2TT39

BOMA: 1159 SF

CRO

RETAIL

T2TS50

BOMA: 1101 SF

CRO

RETAIL

T2TS45

BOMA: 964 SF

POP

STORAGE

T2TS35

BOMA: 3169 SF

2-ADA

HOLDROOM E1

T2TT53

BOMA: 3880 SF

GPA

CIRCULATION

T2TT30

BOMA: 399 SF

CRO

CONCESSION EXTENSION

T2TT35

BOMA: 409 SF

GPM

STAIR 04

T2TU45

BOMA: 168 SF

PMB

SHAFT

TSTT45

BOMA: 401 SF

GPA

CIRCULATION

T2TT31

BOMA: 95 SF

PMB

SHAFT

TSTT25

BOMA: 9049 SF

GPA

CIRCULATION

T2TS53

BOMA: 492 SF

POP

STORAGE LIFT

T2TS30

BOMA: 183 SF

POP

POLICE EQUIPMENT

T2TS23

BOMA: 47 SF

POP

CLOSET

T2TS20

BOMA: 376 SF

CRO

CONCESSION SEATING

T2TS28

BOMA: 1013 SF

SSE

EXIT LANES D & E

T2TS46

BOMA: 205 SF

SSE

OFFICE

T2TR56

BOMA: 88 SF

SSE

EXIT LANE CONTROLS

T2TR53

BOMA: 192 SF

POP

SHARED STORAGE

T2TR42

BOMA: 117 SF

PMB

JANITOR

T2TR46

BOMA: 1487 SF

GTO

RESTROOM ALL-USER

T2TR45

BOMA: 50 SF

SSE

CORRIDOR

T2TR54

BOMA: 1374 SF

PMB

MECHANICAL

T2TS05

BOMA: 89 SF

GPM

STAIR 34

T2TS15

BOMA: 13 SF

PMB

TECH SHAFT

TSTS15

BOMA: 4883 SF

GPA

EXIT PLAZA

T2TS63

BOMA: 1395 SF

GPA

CIRCULATION

T2TS25

BOMA: 1309 SF

GPS

N. MEETER GREETER

T2TR30

BOMA: 9072 SF

GPA

LOBBY

T2TR10

BOMA: 281 SF

GPM

ESC T39

BOMA: 281 SF

GPM

ESC T38

BOMA: 1714 SF

GPA

CONCOURSE BY-PASS VESTIBULE

E20299

BOMA: 446 SF

CPS

STORAGE

E20255

T14T15 T13 T12 T11 1211109876543

TT

TS

EA1

EA

EB

EC1

EC

ED

E1 E2 E3 E4

ST2 085

ST2 075

ST4 008

AE3 027

AE3 028

K10 009

AE3 017

AE3 029

RR10 032

CM2 008

B A

M A

T C

H L

IN

E

G

.2

M A

T C

H L

IN

E

G

.2

AE2 033

ST2 141

MATCHLINE - G2.212

A

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:23:09 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

TERMINAL - ENPLANING - SECTOR 02 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.202

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 02 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

1 REMOVE AREA OF REFUGE SIGN.

PATCH AND REPAIR AS REQUIRED

KEYNOTES:

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/123/attachments/125&autoLoad=true

BOMA: 2815 SF

HOLDROOM E3

E20499

BOMA: 222 SF

3-AUA

MEAL ROOM

E2044

BOMA: 130 SF

PMB

ELECTRICAL

E2024

BOMA: 545 SF

CRO

RETAIL

E20763

BOMA: 1738 SF

CFO

RESTURANT /PUB

E2200

BOMA: 2168 SF

2-ADA

HOLDROOM E4

E2220

BOMA: 523 SF

GTO

MEN

E2216

BOMA: 604 SF

GTO

WOMEN

E2214

BOMA: 267 SF

GPM

STAIRS

E2210

BOMA: 211 SF

GPM

STAIRS TO MEZZANINE

E2204

BOMA: 65 SF

PMB

SHAFT

BOMA: 70 SF

PMB

SHAFT

BOMA: 236 SF

CFO

STORAGE

E2201

BOMA: 325 SF

CFO

KITCHEN

E2202

BOMA: 237 SF

CRO

FOOD CART

TT

EA3

EA2

EA1

EA

EB

EC1

EC

ED

E5 E6 E7 E8 E9 E10 E11 E12

ST2 076

ST2 077

ST4 009

AE2 009

RR10 016

AE3 018

M A

T C

H L

IN

E

G

.2

M A

T C

H L

IN

E

G

.2

RR10 017

RN1 021

RN2 007

RN1 022

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:23:18 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

CONCOURSE E - ENPLANING - SECTOR 03 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.203

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 03 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/124/attachments/126&autoLoad=true

BOMA: 650 SF

GTO

RESTROOM WOMEN

C21074

BOMA: 625 SF

GTO

RESTROOM WOMEN

C21070

BOMA: 531 SF

GTO

RESTROOM MEN

C20974

BOMA: 2377 SF

2-ADA

HOLDROOM C7

C2132

BOMA: 469 SF

2-ADA

HOLDROOM C7 VESTIBULE

C2133

BOMA: 965 SF

CFO

F & B

C2162

BOMA: 916 SF

CFO

F & B

C2160

BOMA: 1125 SF

CRO

RETAIL

C2150

BOMA: 947 SF

CRO

RETAIL

C2152

BOMA: 2224 SF

2-ADA

HOLDROOM C6

C2138

BOMA: 160 SF

CFO

STORAGE

C2137

BOMA: 2347 SF

2-ADA

HOLDROOM C5

C2130

BOMA: 590 SF

GPA

STAIRS

C2136

BOMA: 437 SF

GPM

STAIRS

C2135

BOMA: 193 SF

GPM

STAIRS

C2141A

BOMA: 70 SF

GPM

ELEV C6

C2141

BOMA: 9987 SF

GPA

CIRCULATION

C2142

BOMA: 1023 SF

2-APL

LOUNGE PATIO

C2120A

BOMA: 2310 SF

2-ADA

HOLDROOM C4

C20794

BOMA: 2608 SF

2-ADA

HOLDROOM C3

C20703

BOMA: 603 SF

GTO

RESTROOM MEN

C20970

BOMA: 101 SF

PMB

JANITOR

C20858

BOMA: 3304 SF

2-APL

BOARD ROOM

C2120

BOMA: 110 SF

PMB

SHAFT 33

XC2-33

BOMA: 45 SF

POP

EMS STORAGE

C2131

BOMA: 103 SF

PMB

Room

C2129

BOMA: 21 SF

PMB

SHAFT

BOMA: 42 SF

PMB

Room

BOMA: 296 SF

PMB

CORRIDOR

C2128

177 SF

STAIR 24

C20898

GPM

91 SF

JANITOR

C20858

PMB

518 SF

RESTROOM MEN

C20970

PSF

441 SF

RESTROOM MEN

C20974

PSF

529 SF

RESTROOM WOMEN

C21070

PSF

516 SF

RESTROOM WOMEN

C21074

PSF

2085 SF

HOLDROOM C4

C20794

2-ADA

CE

CD

CB

CC

CA

C08C09C10C11C12C13C14C15C16

TC

TB

AJ

AH

AG

AF

BC

BC'

BA'

CM2 012

B A

CM2 013

B A

FM3 004

FM3 005 FM3 003 FM3 001

RR10 057 RR10 056

ST2 100

AE3 042

ST2 101

ST4 010

AE2 025

GN1 003

PB1 007

AE3 043

K10 021

FD6 010

PB1 008

GN1 004

ST2 102

ST4 011

FD6 001PB1 006

GN1 002

M A

T C

H L

IN

E

G

.2

M A

T C

H L

IN

E

G

.2

RR10 074 RR10 073

IF1 031

IFW 019

RN2 001

IFW 022

RN1 002

IF1 037

IF1 042

PGL7 007

PGL7 008DR1 009

ID1 002

ID1 003

ST2 048

IFW 035

IF1 043

IFW 036

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:24:35 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

CONCOURSE C - ENPLANING - SECTOR 40 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.240

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 40 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

1 DEMOLISH EXISTING OVERHEAD

TRUSS-SUPPORTED SIGN AND

ASSOCIATED STRUCTURAL AND

ELECTRICAL COMPONENTS

2 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

3 REMOVE EMERGENCY

COMMUNICATION SIGN. PATCH AND

REPAIR AS REQUIRED

4 DEMOLISH EXISTING EXTERIOR

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LCOATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

5 REMOVE ILLUMINATED AREA OF

REFUGE SIGN. PATCH AND REPAIR

AS REQUIRED

6 REMOVE AREA OF REFUGE SIGN.

PATCH AND REPAIR AS REQUIRED

KEYNOTES:

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

CLICK ON DOT TO OPEN PHOTO - DRAG PHOTO SCREEN TO "LOOK AROUND"

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/110/attachments/112&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/111/attachments/113&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/112/attachments/114&autoLoad=true

D2689

BOMA: 1553 SF

2-ADA

HOLDROOM D11

D2680

BOMA: 246 SF

3-AUA

COMMON USE STORAGE

D2678

BOMA: 268 SF

GPM

STAIRS TO MEZZANINE

D2669

BOMA: 1032 SF

CRO

UNASSIGNED

D2628

BOMA: 2907 SF

FPU

CHECK POINT

D2627

BOMA: 1177 SF

2-ADA

HOLDROOM D12

D2686

BOMA: 1774 SF

2-ADA

HOLDROOM D10

D2684

BOMA: 954 SF

2-ADA

HOLDROOM D15 OVERFLOW

D2683

BOMA: 855 SF

2-ADA

HOLDROOM D14 OVERFLOW

D2615

BOMA: 858 SF

2-ADA

HOLDROOM D13 OVERFLOW

D2616

BOMA: 879 SF

2-ADA

HOLDROOM D12 OVERFLOW

D2617

BOMA: 692 SF

GPA

SENSORY ROOM

D2601

BOMA: 278 SF

GPM

STAIRS

D2667

BOMA: 97 SF

CPS

COMM ROOM

D2666

BOMA: 95 SF

3-AUA

INFORMATION

D2664

BOMA: 1729 SF

2-APL

LOUNGE

D2652

BOMA: 802 SF

GTO

WOMEN

D2646

BOMA: 155 SF

CPS

PUBLIC SERVICE

D2009A

BOMA: 68 SF

PMB

TELE

D2650

BOMA: 251 SF

PMB

NETWORK

D2630

BOMA: 77 SF

PMB

JANITOR

D2648

BOMA: 580 SF

GPM

STAIRS

D2668

BOMA: 512 SF

GPA

CORRIDOR

D2670

BOMA: 239 SF

CRO

UNASSIGNED

D2632

BOMA: 43 SF

PMB

SHAFT

BOMA: 261 SF

2-APL

VESTIBULE

D2658

BOMA: 104 SF

2-APL

ELEV D10

D2660

BOMA: 63 SF

2-APL

RESTROOM

D2654

BOMA: 84 SF

2-APL

RESTROOM

D2656

BOMA: 189 SF

2-APL

STAIRS TO MEZZANINE

D2662

BOMA: 670 SF

GTO

MEN

D2647

BOMA: 738 SF

2-ADA

HOLDROOM D10 VESTIBULE

D2685

BOMA: 230 SF

2-ADA

VESTIBULE

D2687

HOLDROOM D13 VESTIBULE

BOMA: 332 SF

2-ADA

VESTIBULE

D2693A

BOMA: 663 SF

2-ADA

HOLDROOM D11 VESTIBULE

D2693B

BOMA: 433 SF

3-AUA

OFFICE

D2672

BOMA: 32 SF

CRO

KIOSK

D2009C

BOMA: 13119 SF

GPA

CORRIDOR

D2009

D2648

D2648

D40D41D42D43D44D45D46D47D48

DE

DD

DC

DB

DA

TT

TS

WM2 005

CMB2 013

WM2 006

FM3 027

FM3 026

FM3 028

WM4 001

WM4 002

WM4 003

PB1 031

GN1 027

GN1 030 GN1 028

PB1 032

K10 007

ST2 070

ST4 002

AE2 003

AE3 012

ST4 003

AE2 002

IF2 001

LG1 001

AE3 011

RR10 011RR10 010

M A

T C

H L

IN

E

G

.2

M A

T C

H L

IN

E

G

.2

B

A

IF1 012

IF1 011

IF1 013

RN2 002

RN1 018

RN1 005

FD6 013

FD6 014

FD7 004

IF1 022

IFW 006

RR10 076

ID1 008

ST2 097

ST2 098

RN2 004

RN1 023

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:25:42 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

CONCOURSE D - ENPLANING - SECTOR 52 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.252

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 52 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

1 RELOCATE DOOR CHIME TO 3"

ABOVE DOOR FRAME - PATCH AND

REPAIR EXISTING FINISHES AS

REQUIRED

2 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS. PATCH AND REPAIR

FINISHES. SEE STRUCTURAL AND

ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION

3 DEMOLISH EXISTING

CEILING-SUPPORTED SIGN AND

ASSOCIATED STRUCTURAL AND

ELECTRICAL COMPONENTS. PATCH

AND REPAIR FINISHES. SEE

STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

4 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

5 DEMOLISH EXISTING

SOFFIT-SUPPORTED WALL MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES AS

REQUIRED AFTER NEW WORK IS

COMPLETE. SEE STRUCTURAL AND

ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

6 DEMOLISH EXISTING WALL

MOUNTED CUTOUT LETTERS.

PATCH AND REPAIR EXISTING

FINISHES AS REQUIRED.

7 DEMOLISH EXISTING OVERHEAD

TRUSS-SUPPORTED SIGN AND

ASSOCIATED STRUCTURAL AND

ELECTRICAL COMPONENTS,

PREPARE LOCATION TO RECEIVE

NEW WORK. PATCH AND REPAIR

FINISHES AS REQUIRED AFTER NEW

WORK IS COMPLETE. SEE

STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION.

8 REMOVE D1640 SIGNAGE. PATCH

AND REPAIR AS REQUIRED.

9 REMOVE EXISTING DOOR SIGNAGE.

PATCH AND REPAIR AS REQUIRED.

KEYNOTES:

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

CLICK ON DOT TO OPEN PHOTO - DRAG PHOTO SCREEN TO "LOOK AROUND"

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/108/attachments/110&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/109/attachments/111&autoLoad=true

BOMA: 1244 SF

CRO

RETAIL

D2642

BOMA: 1343 SF

CRO

RETAIL

D2641

BOMA: 2149 SF

FPU

QUEING

D2620

BOMA: 254 SF

GPM

STAIRS

D2624

BOMA: 1000 SF

CRO

RETAIL

D21675

BOMA: 1020 SF

CFO

COFFEE

D2401

BOMA: 335 SF

GPM

STAIRS

D2408

BOMA: 102 SF

3-AUA

COMMON USE STORAGE

D2405

BOMA: 128 SF

PMB

JANITOR

D2221

BOMA: 157 SF

CRO

RETAIL

D2644

BOMA: 20 SF

PMB

MECHANICAL

D2643

BOMA: 81 SF

PMB

SHAFT

BOMA: 38 SF

CRO

STORAGE

D2639

BOMA: 125 SF

CRO

STORAGE

D2640

BOMA: 107 SF

GPM

ELEV D9

D2626

BOMA: 128 SF

GPM

ESC D9

D2622

BOMA: 17 SF

PMB

SHAFT ?

BOMA: 719 SF

GTO

MEN

D2222

D17D18D19D20D21D22D38D39 D23

DE

DD

DC

DB

DA

WM2 002WM2 003WM2 004

FM3 024

FM4 002

FM3 025

FM4 003

GN1 026

PB1 030

GN1 024

PB1 028

PB1 027

GN1 023

PB1 029

GN1 025

MW2 002MW2 001MW1 001

VM4 008

AE2 004

ST4 004

AE3 013

ST2 071

ST4 006

AE2 005

AE3 014

M A

T C

H L

IN

E

G

.2

M A

T C

H L

IN

E

G

.2

IF1 023

IF1 014

IF1 015

FD6 015

FD6 017

FD6 016

IFW 008

IFW 009

PGL7 004

PGL7 003

2 2

RN2 008

IFW 037

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:25:51 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

CONCOURSE D - ENPLANING - SECTOR 53 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.253

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 53 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

1 DEMOLISH EXISTING

SOFFIT-SUPPORTED WALL MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES AS

REQUIRED AFTER NEW WORK IS

COMPLETE. SEE STRUCTURAL AND

ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

2 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

KEYNOTES:

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

CLICK ON DOT TO OPEN PHOTO - DRAG PHOTO SCREEN TO "LOOK AROUND"

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/106/attachments/108&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/107/attachments/109&autoLoad=true

BOMA: 294 SF

PMB

JANITOR

C2039

BOMA: 347 SF

GPM

STAIRS

C2032

BOMA: 77 SF

GPM

ELEV C18

C2034

BOMA: 174 SF

GPM

STAIRS

C2036

BOMA: 60 SF

VESTIBULE

C2037

BOMA: 89 SF

PMB

ELEC

C2038

BOMA: 18061 SF

GPA

CORRIDOR

C2000

CE

CD

CB

CC

CA

CE'

C43C44C45C46C47C48C49

TC

TB

AJ

AH

AG

AF

BC

BC'

BA'

CM2 019

B A

FM3 021

FM3 020

FM3 019

FM3 018

FM3 017

FM3 016

K10 023

IF2 002

PB1 019

GN1 015

ST2 112

ST4 017

AE2 032

DR1 005

AE3 049

ST2 114

FD6 007PB1 021

GN1 017

GN1 019PB1 023

GN1 020PB1 024

PB1 022

GN1 018

PB1 020

GN1 016

FD6 005

FD6 006

M A

T C

H L

IN

E

G

.2

IFW 010

IFW 011

IF1 024

IF1 035

RN1 006

IFW 024

IFW 032

IFW 033

PGL7 005

PGL7 006

RR10 077

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:26:50 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

CONCOURSE C - ENPLANING - SECTOR 70 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.270

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 70 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

1 DEMOLISH EXISTING OVERHEAD

TRUSS-SUPPORTED SIGN AND

ASSOCIATED STRUCTURAL AND

ELECTRICAL COMPONENTS

2 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

3 REMOVE EMERGENCY

COMMUNICATION SIGN. PATCH AND

REPAIR AS REQUIRED

4 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS. PATCH AND REPAIR

FINISHES. SEE STRUCTURAL AND

ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION

5 DEMOLISH EXISTING EXTERIOR

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LCOATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

6 REMOVE ILLUMINATED AREA OF

REFUGE SIGN. PATCH AND REPAIR

AS REQUIRED

KEYNOTES:

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

CLICK ON DOT TO OPEN PHOTO - DRAG PHOTO SCREEN TO "LOOK AROUND"

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/121/attachments/123&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/120/attachments/122&autoLoad=true

BOMA: 294 SF

PMB

JANITOR

C2039

BOMA: 141 SF

PMB

JANITOR

C2041

BOMA: 255 SF

PMB

JANITOR

C2026

BOMA: 1442 SF

CRO

RETAIL

C2072

BOMA: 2373 SF

CFO

F & B

C2076

BOMA: 46 SF

PMB

SHAFT

xC2004

BOMA: 186 SF

GPM

STAIRS TO MEZZANINE

C2056

BOMA: 2174 SF

2-ADA

HOLDROOM C15

C2086

BOMA: 41 SF

PMB

SHAFT 40

XC2-40

BOMA: 46 SF

PMB

SHAFT 41

XC2-41

BOMA: 196 SF

PMB

JANITOR

C2080

BOMA: 1409 SF

CFO

F & B

C2064

BOMA: 1521 SF

CFO

F & B

C2060

BOMA: 81 SF

PMB

SHAFT 43

XC2-43

BOMA: 45 SF

PMB

SHAFT 42

XC2-42

BOMA: 130 SF

BOMA: 82 SF

PMB

SHAFT 39

XC2-39

BOMA: 358 SF

2-ADA

HOLDROOM C15 VESTIBULE

C2078

BOMA: 60 SF

GPA

VESTIBULE

C2037

BOMA: 938 SF

GTO

MEN

C2040

BOMA: 1004 SF

GTO

WOMEN

C2042

BOMA: 497 SF

GPM

STAIRS

C2024

BOMA: 275 SF

CPS

CARTS/LOCKERS

C2022

BOMA: 63 SF

PMB

SHAFT

xC2003

BOMA: 334 SF

CFO

PREP

C2063

BOMA: 222 SF

GPA

CORRIDOR

C2066

BOMA: 108 SF

GPM

ELEV F C16

C2068

BOMA: 441 SF

GPM

STAIRS

C2081

BOMA: 42 SF

CFO

OFFICE

C2077

BOMA: 44 SF

GPA

STORAGE

C2052

BOMA: 17 SF

PMB

SHAFT

xC2001 BOMA: 300 SF

GPA

CORRIDOR

C2051

BOMA: 375 SF

CRO

KIOSK (RMU)

C2070A

CE

CD

CB

CC

CA

CE'

C34C35C36C37C38C39C40C41 C42

TC

TB

AJ

AH

AG

AF

BC

BC'

BA'

CM2 017

B A

CM2 018

B A

FM3 015 FM3 013

FM3 014

RR10 062

FM2 008

RR1 019

RR1 020

RR1 017

FM2 007

RR1 018

GN1 013

ST2 108

ST4 015

FD6 008

PB1 017

ST2 111

AE3 048

PB1 018

GN1 014

ST2 109

ST4 016

ST2 110

PB1 016

GN1 012

FD7 001

FD6 004

MW1 006

MW2 006

M A

T C

H L

IN

E

G

.2

M A

T C

H L

IN

E

G

.2

RR10 063

IF1 025

IFW 012

IFW 013

IFW 014

IF1 028

RN1 007

RN1 008

RN1 009

RN1 011

RN1 010

IFW 029

IFW 030

IFW 031

IF1 040

IF1 039

IF1 041

2 3

RN1 027

RN1 028

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:27:06 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

CONCOURSE C - ENPLANING - SECTOR 71 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.271

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 71 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

1 DEMOLISH EXISTING OVERHEAD

TRUSS-SUPPORTED SIGN AND

ASSOCIATED STRUCTURAL AND

ELECTRICAL COMPONENTS

2 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

3 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS. PATCH AND REPAIR

FINISHES. SEE STRUCTURAL AND

ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION

4 DEMOLISH EXISTING EXTERIOR

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LCOATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

5 REMOVE AREA OF REFUGE SIGN.

PATCH AND REPAIR AS REQUIRED

6 REMOVE EMERGENCY

COMMUNICATION SIGN. PATCH AND

REPAIR AS REQUIRED

KEYNOTES:

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

CLICK ON DOT TO OPEN PHOTO - DRAG PHOTO SCREEN TO "LOOK AROUND"

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/117/attachments/119&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/118/attachments/120&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/119/attachments/121&autoLoad=true

BOMA: 220 SF

HOLDROOM C12 VESTIBULE

C2191

BOMA: 699 SF

CPS

SVC CENTER

C23135

BOMA: 3340 SF

CFO

F & B

C2192

BOMA: 190 SF

PMB

JANITOR

C2196

BOMA: 140 SF

UNA

Area

C219??

PMB

SHAFT 36

XC2-36

BOMA: 70 SF

PMB

SHAFT 37

XC2-37

CRO

ATM

C2003a

BOMA: 100 SF

PMB

JANITOR

C2188

BOMA: 70 SF

CRO

RETAIL

C2003c

BOMA: 50 SF

CRO

RETAIL

C2003b

BOMA: 1211 SF

CRO

RETAIL

C2180A

BOMA: 1193 SF

CRO

RETAIL

C22560

BOMA: 86 SF

PMB

ELECTRICAL

C2089

BOMA: 87 SF

2-ADA

HOLDROOM C13 VESTIBULE

C2092

BOMA: 70 SF

PMB

SHAFT

BOMA: 375 SF

GPM

STAIRS

C2195

BOMA: 216 SF

GPA

CORRIDOR

C23037

BOMA: 775 SF

GTO

MEN

C2189

BOMA: 1094 SF

GTO

WOMEN

C2187

CE

CD

CB

CC

CA

C25C26C27C28C29C30C31C32C33

TC

TB

AJ

AH

AG

AF

BC

BC'

BA'

CM2 015

B A

CM2 016

B A

FM3 011

FM3 012 FM3 010

FM3 009

RR10 060

RR10 061

K10 022

MW1 005

MW2 005

FM2 005

RR1 013

RR1 014

AE3 046

MW1 004 MW2 004

FM2 006

RR1 015

RR1 016

GN1 009

PB1 013

GN1 011

PB1 015

AE3 047

PB1 014

GN1 010

ST2 107

ST4 014

AE2 029

ST2 106

GN1 008

PB1 012 FD6 003

CBL 001

M A

T C

H L

IN

E

G

.2

M A

T C

H L

IN

E

G

.2

IF1 026

IFW 015

IFW 021

IF1 034

RN1 012

RN2 010

IF1 036

IFW 026

IFW 027

IFW 028

ID1 010

RN1 030

RN1 013

RN2 009

RN1 029

RN1 031

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:27:24 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

CONCOURSE C - ENPLANING - SECTOR 72 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.272

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 72 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

1 DEMOLISH EXISTING OVERHEAD

TRUSS-SUPPORTED SIGN AND

ASSOCIATED STRUCTURAL AND

ELECTRICAL COMPONENTS

2 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

3 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS. PATCH AND REPAIR

FINISHES. SEE STRUCTURAL AND

ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION

4 DEMOLISH EXISTING EXTERIOR

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LCOATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

5 REMOVE ILLUMINATED AREA OF

REFUGE SIGN. PATCH AND REPAIR

AS REQUIRED

KEYNOTES:

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

CLICK ON DOT TO OPEN PHOTO - DRAG PHOTO SCREEN TO "LOOK AROUND"

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/115/attachments/117&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/116/attachments/118&autoLoad=true

BOMA: 271 SF

HOLDROOM C8 VESTIBULE

C2145

BOMA: 2486 SF

2-ADA

HOLDROOM C8

C2172

BOMA: 10931 SF

GPA

CIRCULATION

C2144

BOMA: 431 SF

PMB

JANITOR

C2181

BOMA: 141 SF

PMB

JANITOR

C2175

BOMA: 79 SF

PMB

ELECTRICAL

C2173 BOMA: 314 SF

PMB

JANITOR

C2146

BOMA: 1180 SF

CFO

F & B

C2168

BOMA: 959 SF

CFO

F & B

C2166

BOMA: 959 SF

CFO

F & B

C2164

BOMA: 947 SF

CRO

RETAIL

C2154

BOMA: 947 SF

CRO

RETAIL

C2156

BOMA: 769 SF

CRO

RETAIL

C2158

BOMA: 90 SF

PMB

SHAFT 34

XC2-34

BOMA: 1046 SF

GTO

WOMEN

C2176

BOMA: 865 SF

GTO

MEN

C2177

BOMA: 206 SF

GPM

CORRIDOR

C2147

BOMA: 501 SF

GPM

STAIRS

C2171

BOMA: 75 SF

PMB

SHAFT 35

XC2-35

BOMA: 390 SF

GPA

STAIRS

C2182

BOMA: 87 SF

PMB

SHAFT

CS21##

BOMA: 114 SF

GPM

VESTIBULE

C2184

BOMA: 187 SF

GPM

ELEV C10

C2185

BOMA: 216 SF

PMB

ELECTRICAL

C2183

BOMA: 88 SF

GPM

ELEV F C8

C2143

BOMA: 56 SF

GPM

VESTIBULE

C2143A

BOMA: 82 SF

PMB

SHAFT

XC2005

CE

CD

CB

CC

CA

C17C18C19C20C21C22C23C24

TC

AJ

AH

AG

AF

BC

BC'

BA'

CM2 014

B A

FM3 008

FM3 007

FM3 006

RR10 058

RR10 059

PB1 009

GN1 005

VM4 010

AE3 044

GN1 007

PB1 011FD6 009

VM4 009

ST2 104

ST2 105

AE2 028

ST4 013

AE3 045

FD7 002 PB1 010

GN1 006

RR1 012

FM2 004

RR1 011 RR1 009

FM2 003

RR1 010

MW2 003

MW1 003

ST2 103

ST4 012

AE2 027

FD6 002

M A

T C

H L

IN

E

G

.2

M A

T C

H L

IN

E

G

.2

IF1 027

IFW 016

IFW 017

IF1 029

IF1 032

IF1 033

IFW 020

RN2 006

RN1 014

RN1 015

RN1 016

RN1 017

IFW 023

IFW 025

IF1 038

ID1 009

SIGN LEGEND:

SIGN NUMBER

SIGN TYPE

AA 123

NOTES:

1. SIGN LOCATION PLAN IS FOR

GENERAL REFERENCE ONLY.

TARGETS REFERENCE G9.051 THRU

G9.052 SIGN FAMILY SHEETS.

2. SEE COMMENTS IN MESSAGE SCHEDULE

FOR SIGNS THAT NEED EXISTING SIGNS

TO BE REMOVED AND DISPOSED OF

PRIOR TO SIGN INSTALL.

/4

/2

G R

A P

H

IC

S C

A L E

-F O

R R

E F

E R

E N

C E

O N

L Y

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS

A

PP

C A

N Y

O U

S E

E T

H E

A

IR

P L A

N E

S

T

H E

A D

J A

C E

N T

S A

M P

L E

S S

H O

W T

H R

E E

D

IF

F E

R E

N T

L E

V E

L S

O F

S H

A D

IN

G

S

E T

T

IN

G S

F O

R V

IE

W

IN

G

A N

D P

R

IN

T

IN

G D

R A

W

IN

G C

O N

T E

N T

A R

E O

P T

IM

IZ

E D

W H

E N

A L L T

H R

E E

P L A

N E

S A

R E

V

IS

IB

L E

T

H

IS

G U

ID

A

N C

E I S

P R

O V

ID

E

D F

O R

R E

F E

R E

N C

E O

N L Y b la c k g ra y g ra y lig h t d a rk

NO. DATE BY REVISIONS

A

PP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

A W

IN

G

S C

A L E

I S

R E

D U

C E

D

W H

E N

S H

E E

T S

IZ

E

I S x

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:27:37 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

CONCOURSE C - ENPLANING - SECTOR 73 - FLOOR PLAN - SIGNAGE

PORTLAND INTERNATIONAL AIRPORT

G2.273

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

N

KEY PLAN

SCALE: N.T.S.

SCALE: 1/8" = 1'-0"

ENPLANING - SECTOR 73 - FLOOR PLAN

24'16'8'4'0"

SCALE: IN FEET

N

1 DEMOLISH EXISTING OVERHEAD

TRUSS-SUPPORTED SIGN AND

ASSOCIATED STRUCTURAL AND

ELECTRICAL COMPONENTS

2 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LOCATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

3 DEMOLISH EXISTING

SOFFIT-SUPPORTED FLAG MOUNT

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS. PATCH AND REPAIR

FINISHES. SEE STRUCTURAL AND

ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION

4 DEMOLISH EXISTING EXTERIOR

SIGN AND ASSOCIATED

STRUCTURAL AND ELECTRICAL

COMPONENTS, AND PREPARE

LCOATION TO RECEIVE NEW WORK.

PATCH AND REPAIR FINISHES

AFTER NEW WORK IS COMPLETE.

SEE STRUCTURAL AND ELECTRICAL

DRAWINGS FOR ADDITIONAL

INFORMATION

5 REMOVE ILLUMINATED AREA OF

REFUGE SIGN. PATCH AND REPAIR

AS REQUIRED

KEYNOTES:

ENHANCED DRAWING - FOR REFERENCE ONLY

PANORAMIC PHOTO LOCATION

CLICK ON DOT TO OPEN PHOTO - DRAG PHOTO SCREEN TO "LOOK AROUND"

https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/113/attachments/115&autoLoad=true https://cdn.pannellum.org/2.5/pannellum.htm#panorama=https%3A//services1.arcgis.com/DSTsMrzgcyf3Fkz4/arcgis/rest/services/Virtual_Tour_Photos/FeatureServer/0/114/attachments/116&autoLoad=true

File details come from the government source that posted it. Updated .