PDX 2026-512 (12) S2.200.pdf
PDF 244 KB Posted
- Solicitation number
- 144651
- Issued by
- Multnomah County, Oregon
About this file
This is a structural floor plan drawing for the Portland International Airport (PDX) Terminal and Concourses Wayfinding Signage project (PDX 2026-512), prepared by Jay Ostlund Architects. The drawing depicts Concourse D in the enplaning area, Sector 00, and shows the structural layout for the installation of wayfinding signage throughout the terminal building and concourses. The project involves providing directional and informational signage in various formats including blade signs, concession blade signs, hanging signs, hanging wall signs, and gate signs, with detailed specifications referenced in sheets S6.100 through S6.130. The drawing is dated August 2026 and was last revised on July 27, 2026, with a professional certification expiration date of December 31, 2026.
The structural plan includes detailed notations requiring the contractor to verify all existing conditions, dimensions, and elevations prior to fabrication and erection, with mandatory reporting of any significant discrepancies to the architect. The contractor must provide shoring for all existing framing during demolition and re-framing work, and inspect all exposed framing for cracks and damage. The drawing is presented at a scale of 1/8" = 1'-0" and includes a comprehensive legend identifying various structural elements, existing conditions, elevation markers, and sign type designations. The document serves as the authoritative reference for structural coordination and sign placement locations, sizes, and elevations across the concourse floor plan.
View the file
Other files
Show 40 more
Latest 50 of 247 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DA
DB
DC
DD
DE
VV
TV
D11D12D13D14D15D16 D10 D09 D08
30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0"
PB1-1
FM4-2
FM3-2
M A
T C
H L
IN
E
S
E E
S H
E E
T S
.2
PB1-1
ABOVE
ABOVE
ABOVE
ABOVE
INDICATES EXISTING.
INDICATES EXISTING STRUCTURE.
INDICATES STEP IN ELEVATION.
INDICATES CHANGE IN SLOPE.
INDICATES TOP OF SLAB ELEVATION.
INDICATES BOTTOM OF DECK ELEVATION.
INDICATES COLUMN BELOW.
INDICATES EXISTING ABOVE SLAB TREE
PLANTER
INDICATES AREA OF EXISTING
OVERFRAMING.
INDICATES SEISMIC JOINT.
INDICATES EXISTING TECH POLE
LOCATION.
INDICATES EXISTING ITP 2 AND 3.
INDICATES NEW BLADE SIGN
SEE SHEET S6.100. Y - INDICATES DETAIL
NUMBER.
INDICATES NEW CONCESSION BLADE
SIGN, SEE SHEET S6.101. Y - INDICATES
DETAIL NUMBER.
INDICATES NEW HANGING SIGN
SEE SHEET S6.110. Y - INDICATES DETAIL
NUMBER.
INDICATES NEW HANGING SIGN ON WALL
SEE SHEET S6.120. Y - INDICATES DETAIL
NUMBER.
INDICATES NEW GATE SIGN
SEE SHEET S6.130. Y - INDICATES DETAIL
NUMBER.
EL. XXX'-XX"
EL. XXX'-XX"
NOTE(S):
1. CONTRACTOR TO VERIFY ALL EXISTING
CONDITIONS, DIMENSIONS, AND ELEVATIONS
PRIOR TO FABRICATION AND ERECTION. NOTIFY
ARCHITECT OF ANY SIGNIFICANT DISCREPANCIES
ROM THOSE SHOWN ON THE DRAWINGS.
2. CONTRACTOR TO SHORE ALL EXISTING FRAMING
AS REQUIRED FOR DEMOLITION AND RE-FRAMING
WORK.
3. ALL EXPOSED FRAMING SHALL BE INSPECTED FOR
CRACKS AND DAMAGE BY THE CONTRACTOR AND
FINDINGS REPORTED TO THE ARCHITECT.
4. SEE SHEETS S6.100 THRU S6.130 FOR TYPICAL
SIGN DETAILS.
5. SEE SIGNAGE FOR EXACT LOCATION, SIZE AND
ELEVATION OF SIGNS.
LEGEND:
FMX-Y
(E)
CMX-Y
PBX-Y
WMX-Y
CBL-Y
/4
/2
G R
A P
H
IC
S C
A L E
-F O
R R
E F
E R
E N
C E
O N
L Y
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".
SUBMITTED BY
DESIGNED BY
DRAWN BY
CHECKED BY
DATE
SHEET NO.
DRAWING NO.
TYPE
DISC. SHT. NO.
EAN PAN
NO. DATE BY REVISIONS
A
PP
C A
N Y
O U
S E
E T
H E
A
IR
P L A
N E
S
T
H E
A D
J A
C E
N T
S A
M P
L E
S S
H O
W T
H R
E E
D
IF
F E
R E
N T
L E
V E
L S
O F
S H
A D
IN
G
S
E T
T
IN
G S
F O
R V
IE
W
IN
G
A N
D P
R
IN
T
IN
G D
R A
W
IN
G C
O N
T E
N T
A R
E O
P T
IM
IZ
E D
W H
E N
A L L T
H R
E E
P L A
N E
S A
R E
V
IS
IB
L E
T
H
IS
G U
ID
A
N C
E I S
P R
O V
ID
E
D F
O R
R E
F E
R E
N C
E O
N L Y b la c k g ra y g ra y lig h t d a rk
NO. DATE BY REVISIONS
A
PP
IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING
TYPE
D R
A W
IN
G
S C
A L E
I S
R E
D U
C E
D
W H
E N
S H
E E
T S
IZ
E
I S x
B▲ A▲
7/21/2026 2:34:25 PM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX-103101-STR_Signage-Walkway.rvt
CONCOURSE D - ENPLANING - SECTOR 00 - FLOOR PLAN - STRUCTURAL
PORTLAND INTERNATIONAL AIRPORT
S2.200
AUGUST 2026
A. MONNIER
J. DE BOER
S. THOMAS
JAY OSTLUND
TERMINAL AND CONCOURSES WAYFINDING SIGNAGE
PDX 2026-512
CD
1031012026D004
SCALE: 1/8" = 1'-0"1
CONCOURSE D - ENPLANING - SECTOR 00 - FLOOR PLAN - STRUCTURAL
111 SW Fifth Ave., Suite 2600 Portland, OR 97204 O 503.227.3251 - F 503.227.7980
24'16'8'4'0'
SCALE: IN FEET
N
N
KEY PLAN
SCALE: N.T.S.
EXPIRES 12/31/202606/30/2028
7/27/2026
| 2026-07-27T15:39:38-0700 | |
| James Vodden |
File details come from the government source that posted it. Updated .