PDX 2026-512 (169) G2.242.pdf
PDF 562 KB Posted
- Solicitation number
- 144651
- Issued by
- Multnomah County, Oregon
About this file
This is a floor plan signage drawing for Portland International Airport, a facility operated by the State of Oregon. The document provides a detailed sign location plan for the Terminal Enplaning Sector 42, specifying the placement and identification of wayfinding signage throughout the concourse area. The drawing includes multiple sign locations referenced by sign numbers and types, with corresponding BOMA (Building Owners and Managers Association) square footage measurements for various functional areas including holdrooms, restrooms, retail spaces, circulation areas, and support facilities. The plan references additional sign family sheets (G9.051 through G9.052) for detailed sign specifications and indicates that existing signs in certain locations require removal and disposal prior to new sign installation. The document is dated August 2026 and was prepared at a scale of 1/8" equals 1 foot, with notation that the drawing scale is reduced 50% when printed on 17" by 22" sheet size.
The drawing serves as a reference plan for the wayfinding signage project at Portland International Airport's terminal and concourse areas. Key note 169 identifies a specific action item requiring the removal of an area of refuge sign with subsequent patching and repair as needed. The document includes a key plan for orientation and establishes matchlines to adjacent drawing sheets (G2.241 and G2.243) to ensure comprehensive coverage of the signage installation scope across multiple sectors of the terminal facility.
View the file
Other files
Show 40 more
Latest 50 of 247 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BOMA: 2092 SF
2-ADA
HOLDROOM B3
B21001
BOMA: 1003 SF
CRO
NEWSTAND
T2TA34
BOMA: 1056 SF
CRO
RETAIL
T2TA36
BOMA: 620 SF
CRO
RETAIL
T2TB53
BOMA: 568 SF
CRO
RETAIL
T2TB50
BOMA: 14673 SF
2-ADA
HOLDROOM B1
T2TA53
BOMA: 779 SF
GTO
WOMEN
T2TB44
BOMA: 733 SF
GTO
MEN
T2TB38
BOMA: 137 SF
PMB
JANITOR
T2TB40
BOMA: 410 SF
POP
STORAGE LIFT
T2TB32
BOMA: Redundant Area
GPA
CIRCULATION
T2TA55
BOMA: Redundant Area
GPS
SEATING
T2TA40
BOMA: 201 SF
GPM
STAIR 22
T2TA38
BOMA: 55 SF
PMB
ELECTRICAL
T2TA32
BOMA: 88 SF
POP
SHARED STORAGE
T2TA33
GPM
STAIR 23
BOMA: 935 SF
GPA
EXIT LANES B & C
T2TB48
BOMA: 185 SF
POP
SHARED STORAGE
T2TC42
BOMA: 1464 SF
GTO
RESTROOM ALL-USER
T2TC45
BOMA: 119 SF
PMB
JANITOR
T2TC43
BOMA: 172 SF
PMB
SHAFT
TSTB26
BOMA: 93 SF
GPM
T EL 9
T2TB25
BOMA: 53 SF
PMB
SHAFT
TSTB25
BOMA: 205 SF
POP
POLICE EQUIPMENT
T2TB22
BOMA: 182 SF
POP
INTERVIEW
T2TB26
BOMA: 290 SF
GPM
STAIRS 33
T2TB15
BOMA: 64 SF
PMB
SHAFT
TSTB15
BOMA: 29 SF
POP
CLOSET
T2TB16
BOMA: 765 SF
POP
SHARED STORAGE
T2TB18
BOMA: 206 SF
SSE
OFFICE
T2TC56
BOMA: 90 SF
SSE
EXIT LANE CONTROLS
T2TC50
T2TB12
BOMA: 74 SF
POP
ELECTRICAL
T2TB06
BOMA: 38 SF
POP
VESTIBULE
T2TB05
BOMA: 600 SF
POP
SHARED STORAGE
T2TB07
BOMA: 134 SF
POP
SHARED STORAGE
T2TB14
BOMA: 159 SF
POP
SHARED STORAGE
T2TB13
BOMA: 318 SF
POP
SHARED STORAGE
T2TB09
BOMA: 87 SF
PMB
SHAFT
TSTB12
BOMA: 329 SF
POP
CANINE UNIT
T2TB17
BOMA: 346 SF
POP
VESTIBULE
T2TB21
BOMA: 18 SF
POP
CLOSET
T2TB20
BOMA: 51 SF
SSE
CORRIDOR
T2TC53
BOMA: 2105 SF
2-ADA
HOLDROOM B4
B21221
BOMA: 269 SF
GPM
ESC T35
BOMA: 269 SF
GPM
ESC T34
BOMA: 1496 SF
GPA
CIRCULATION
T2TB27
BOMA: 1290 SF
GPS
S. MEETER/GREETER AREA
T2TC30
BOMA: 414 SF
GPA
CIRCULATION
T2TC40
BOMA: 1233 SF
2-ADA
HOLDROOM B2
BOMA: 319 SF
2-ADA
UNACCOMPANIED MINORS ROOM
BOMA: 280 SF
2-ADA
HOLDROOM B2 VESTIBULE
T14T15 T13 T12 T11 1211109876543
TC
TB
AJ
AH
AG
AF
BC
BC'
BA'
E1 E2 E3 E4
ST2 095
RR10 054
RR10 055
ST2 096
RR10 050
AE3 037
AE3 040
M A
T C
H L
IN
E
G
.2
M A
T C
H L
IN
E
G
.2
K10 024
ST2 138
ST3 003
ST3 002
MATCHLINE - G2.232
SIGN LEGEND:
SIGN NUMBER
SIGN TYPE
AA 123
NOTES:
1. SIGN LOCATION PLAN IS FOR
GENERAL REFERENCE ONLY.
TARGETS REFERENCE G9.051 THRU
G9.052 SIGN FAMILY SHEETS.
2. SEE COMMENTS IN MESSAGE SCHEDULE
FOR SIGNS THAT NEED EXISTING SIGNS
TO BE REMOVED AND DISPOSED OF
PRIOR TO SIGN INSTALL.
/4
/2
G R
A P
H
IC
S C
A L E
-F O
R R
E F
E R
E N
C E
O N
L Y
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".
SUBMITTED BY
DESIGNED BY
DRAWN BY
CHECKED BY
DATE
SHEET NO.
DRAWING NO.
TYPE
DISC. SHT. NO.
EAN PAN
NO. DATE BY REVISIONS
A
PP
C A
N Y
O U
S E
E T
H E
A
IR
P L A
N E
S
T
H E
A D
J A
C E
N T
S A
M P
L E
S S
H O
W T
H R
E E
D
IF
F E
R E
N T
L E
V E
L S
O F
S H
A D
IN
G
S
E T
T
IN
G S
F O
R V
IE
W
IN
G
A N
D P
R
IN
T
IN
G D
R A
W
IN
G C
O N
T E
N T
A R
E O
P T
IM
IZ
E D
W H
E N
A L L T
H R
E E
P L A
N E
S A
R E
V
IS
IB
L E
T
H
IS
G U
ID
A
N C
E I S
P R
O V
ID
E
D F
O R
R E
F E
R E
N C
E O
N L Y b la c k g ra y g ra y lig h t d a rk
NO. DATE BY REVISIONS
A
PP
IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING
TYPE
D R
A W
IN
G
S C
A L E
I S
R E
D U
C E
D
W H
E N
S H
E E
T S
IZ
E
I S x
B▲ A▲ PDX 2026-5122026D004 103101
CD
7/21/2026 11:24:58 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt
TERMINAL - ENPLANING - SECTOR 42 - FLOOR PLAN - SIGNAGE
PORTLAND INTERNATIONAL AIRPORT
G2.242
AUGUST 2026
K. FRY
B. STEVENS
B. STEVENS
JAY OSTLUND
TERMINAL AND CONCOURSES WAYFINDING SIGNAGE
N
KEY PLAN
SCALE: N.T.S.
SCALE: 1/8" = 1'-0"
ENPLANING - SECTOR 42 - FLOOR PLAN
24'16'8'4'0"
SCALE: IN FEET
N
1 REMOVE AREA OF REFUGE SIGN.
PATCH AND REPAIR AS REQUIRED
KEYNOTES: