PDX 2026-512 (215) G9.110.pdf
PDF 328 KB Posted
- Solicitation number
- 144651
- Issued by
- Multnomah County, Oregon
About this file
This is a technical drawing specification document for Portland International Airport's Terminal and Concourses Wayfinding Signage project, prepared by the State of Oregon through the Portland International Airport authority. The project involves the design and installation of illuminated wayfinding signage systems throughout the airport terminal and concourses, specifically detailing signage unit CMB2. The specifications include four modular sign cabinets measuring 1 foot by 13 feet by 3.5 inches each, constructed from soft aluminum frames painted in Port White finish with removable end caps. The visible sign face dimensions are 12 feet 11 inches wide by 11.25 inches high, with the overall printed fabric measuring 13 feet 2 inches by 1 foot 2 inches. The signage incorporates white translucent fabric substrates with direct-printed graphics using UV inks, featuring wayfinding messages for Ground Transportation, Restrooms, Baggage Claim, Gates D10-D15, Ticketing, and various concourse locations (B, C, D, and E).
The signage system utilizes back-illumination with LED modules operating at 6700K color temperature for cabinet illumination and 6500K for light bar illumination, both dimmable and connected to a lighting controller system compatible with the Airport Management System. Electrical specifications include a 20-amp rated incoming power circuit disconnect rated for 120/277V AC, with electrical connections routed through the structural support system. The design employs Helvetica Neue LT Std Light font with a 4-inch cap height and utilizes Pantone colors 2955 (opaque background), 7462 (translucent copy and graphics), and 2379 (graphic container strokes). The drawings include detailed mounting conditions, alignment marks for installation precision, and references to division 26 electrical contractor responsibilities. Sign fabrication is specified to meet SIGNCOMP front-load standards with even illumination and no visible shadows from internal hardware components.
View the file
Other files
Show 40 more
Latest 50 of 247 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/
4" 1/
2" 1"
2"
G R
AP
H
IC
S
C
AL
E-
FO
R R
EF
ER
EN
C
E O
N
LY
DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".
SUBMITTED BY
DESIGNED BY
DRAWN BY
CHECKED BY
DATE
SHEET NO.
DRAWING NO.
TYPE
DISC. SHT. NO.
EAN PAN
NO. DATE BY REVISIONS APP
C
AN
Y O
U S
EE
T
H E
AI
R
PL
AN
ES
T H
E
AD
JA
C
EN
T
SA
M
PL
ES
S H
O W
T H
R
EE
D
IF
FE
R
EN
T
LE
VE
LS
O
F
SH
AD
IN
G
SE
TT
IN
G
S
FO
R V
IE
W
IN
G
A N
D P
R
IN
TI
N
G D
R
AW
IN
G
C O
N
TE
N T
AR
E
O
PT
IM
IZ
ED
W
H
EN
A
LL
T H
R
EE
P
LA
N
ES
A R
E
VI
SI
BL
E.
T
H
IS
G U
ID
AN
C E
IS
P
R O
VI
D
ED
F
O R
R
EF
ER
EN
C E
O N
LY
bl ac k gr ay gr ay lig ht da rk
NO. DATE BY REVISIONS APP
IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING
TYPE
D R
AW
IN
G S
C
AL
E
IS
R
ED
U C
ED
0% W
H
EN
S H
EE
T
SI
ZE
IS
7" x
2"
B▲ A▲ PDX 2026-5122026D004 103101
CD
7/21/2026 11:08:13 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt
SIGN DETAILS 10
PORTLAND INTERNATIONAL AIRPORT
G9.110
AUGUST 2026
K. FRY
B. STEVENS
B. STEVENS
JAY OSTLUND
TERMINAL AND CONCOURSES WAYFINDING SIGNAGE
CMB2 - SECTION
SCALE: 1" = 1' - 0"
LE
N
G
TH
O F
V
ER
TI
C
A L
M O
U N
TI
N
G S
U
PP
O R
T
VA
R
IE
S D
EP
EN
D
IN
G O
N C
EI
LI
N G
H
EI
G H
T
ELECTRICAL
CONNECTION TO STRUCTURAL SUPPORT
VARIES PER LOCATION, SEE STRUCTURAL
POWER SUPPLY: CONFIRM COMPATIBILITY
WITH AIRPORT MANAGEMENT SYSTEM.
POWER SUPPLY TO BE LOCATED IN TOP
CABINET (PER SIDE)
CABINET ILLUMINATION: LED 6700K MODULES,
DIMMABLE AND CONNECTED TO LIGHTING
CONTROLLER
INNER MOUNTING PLATE
LIGHT BAR ILLUMINATION: LED PRISM
6500K WHITE MODULES, DIMMABLE AND
CONNECTED TO LIGHTING CONTROLLER
HORIZONTAL ALUMINUM PIPE
MOUNTING PLATE – CONNECTION TO
SIGN CABINET, SPACING AND VERTICAL
CONNECTION BY STRUCTURAL
NOTE:
INCOMING WIRING BY DIVISION 26 ELECTRICAL CONTRACTOR,
SIGN MANUFACTURER TO LOCATE AND PROVIDE DEVICES NOTED.
INCOMING POWER CIRCUIT DISCONNECT,
20 AMP RATED, 120/277V AC
ETC FOUNDRY DMX TO 0-10V CONVERTER
Ground TransportationRestrooms
Baggage ClaimConcourse B C D
CMB2 - ELEVATION
SCALE: 1" = 1' - 0"
2'
0"
1'
0" 1'
0"
3"
13' - 0"
8' - 4"
LE
N
G
TH
O F
V
ER
TI
C
A L
M O
U N
TI
N
G
SU
PP
O
R T
VA
R
IE
S
D
EP
EN
D
IN
G
O N
C
EI
LI
N
G H
EI
G
H T
LIGHT BAR
FABRIC SIGN FACE: WHITE TANSLUCENT
FABRIC SUBSTRATE WITH OPAQUE AND
TRANSLUCENT DIRECT PRINT GRAPHICS
APPLIED WITH UV INKS. ILLUMINATION TO BE
EVEN WITH NO SHADOWS FROM INTERNAL
HARDWARE. BACKGROUND TO BE OPAQUE
AND MATCH PANTONE 2955. COPY AND
GRAPHICS TO BE TRANSLUCENT AND
MATCH PANTONE 7462 AND WHITE. SQUARE
GRAPHIC CONTAINER TO HAVE
4 POINT STROKE TO MATCH PANTONE 2379.
ENTIRE SIGN FACE INTENDED TO BE BACK
ILLUMINATED. FONT: HELVETICA NEUE LT
STD LIGHT CAP HEIGHT 4"
CABINET: (4) 1' - 0" X 13' - 0" X 3 1/2"
SIGNCOMP FRONT LOAD SOFT ALUMINUM
SIGNAGE FRAME PART #3095, PAINTED
PORT WHITE
REMOVABLE END CAP PAINTED PORT WHITE
3" 2" 7" 3"7"7"
2.5" 2.5"
CMB2 - FABRIC FACE PRINTED ALIGNMENT MARKS
SCALE: 1" = 1' - 0"
13' - 2"
3' - 3 1/2" 3' - 3 1/2" 3' - 3 1/2"3' - 3 1/2"
1'
2"
VISIBLE SIGN FACE:
12' - 11" W X 11-1/4" H
PRINTED THIN BORDER LINE TO MATCH
PANTONE 7462. USE FOR PRECISE
ALIGNMENT OF FABRIC WITH SIGN
CABINET DURING INSTALLATION.
13' - 0" W X 1' - 0" H
OVERALL PRINTED FABRIC:
13' - 2" W X 1' - 2" H
COLOR TO MATCH PANTONE 2955
PROVIDE EQUIDISTANT THIN LINES TO
MATCH PANTONE 7462. PRINT 6 TOTAL, 3
ON TOP AND 3 ON BOTTOM EDGE OF
FABRIC FACE. USE FOR PRECISE
ALIGNMENT OF FABRIC WITH SIGN
CABINET DURING INSTALLATION.
Gates D10-D15
Ticketing
Concourse B C E
Concouse B C EGates D10-D15
Ticketing
SCALE: 1" = 1' - 0"
CMB2 - MESSAGE LAYOUTS2
CMB2-013 A
CMB2-013 B
15' - 0" A .F.F.
TO
TO
P O
F SIG
N
CMB2 - MOUNTING CONDITION
SCALE: 1/4" = 1' - 0"
SEE STRUCTURAL
FOR ABOVE CEILING
ATTACHMENT
NOTE:
SEE FABRICATION DETAILS FOR CM2
G9.103
G9.104
G9.104
G9.105
File details come from the government source that posted it. Updated .