PDX 2026-512 (215) G9.110.pdf

PDF 328 KB Posted

Attached to
Portland International Airport Terminal and Concourses Wayfinding Signage
Solicitation number
144651
Issued by
Multnomah County, Oregon

About this file

This is a technical drawing specification document for Portland International Airport's Terminal and Concourses Wayfinding Signage project, prepared by the State of Oregon through the Portland International Airport authority. The project involves the design and installation of illuminated wayfinding signage systems throughout the airport terminal and concourses, specifically detailing signage unit CMB2. The specifications include four modular sign cabinets measuring 1 foot by 13 feet by 3.5 inches each, constructed from soft aluminum frames painted in Port White finish with removable end caps. The visible sign face dimensions are 12 feet 11 inches wide by 11.25 inches high, with the overall printed fabric measuring 13 feet 2 inches by 1 foot 2 inches. The signage incorporates white translucent fabric substrates with direct-printed graphics using UV inks, featuring wayfinding messages for Ground Transportation, Restrooms, Baggage Claim, Gates D10-D15, Ticketing, and various concourse locations (B, C, D, and E).

The signage system utilizes back-illumination with LED modules operating at 6700K color temperature for cabinet illumination and 6500K for light bar illumination, both dimmable and connected to a lighting controller system compatible with the Airport Management System. Electrical specifications include a 20-amp rated incoming power circuit disconnect rated for 120/277V AC, with electrical connections routed through the structural support system. The design employs Helvetica Neue LT Std Light font with a 4-inch cap height and utilizes Pantone colors 2955 (opaque background), 7462 (translucent copy and graphics), and 2379 (graphic container strokes). The drawings include detailed mounting conditions, alignment marks for installation precision, and references to division 26 electrical contractor responsibilities. Sign fabrication is specified to meet SIGNCOMP front-load standards with even illumination and no visible shadows from internal hardware components.

View the file

Other files

File Type Posted
PDX 2026-512 (134) G2.103.pdf PDF
PDX 2026-512 (155) G2.172.pdf PDF
PDX 2026-512 (128) G2.071.pdf PDF
PDX 2026-512 (146) G2.151.pdf PDF
PDX 2026-512 (47) E1.273.pdf PDF
PDX 2026-512 (71) E2.753.pdf PDF
PDX 2026-512 (147) G2.152.pdf PDF
PDX 2026-512 (102) G0.001.pdf PDF
PDX 2026-512 (42) E0.300.pdf PDF
PDX 2026-512 (85) E9.004.pdf PDF
PDX 2026-512 (17) S2.253.pdf PDF
PDX 2026-512 (98) T4.001.pdf PDF
PDX 2026-512 (193) G2.342.pdf PDF
PDX 2026-512 (132) G2.101.pdf PDF
PDX 2026-512 (76) E5.001.pdf PDF
PDX 2026-512 (169) G2.242.pdf PDF
PDX 2026-512 (242) G9.137.pdf PDF
PDX 2026-512 (172) G2.252.pdf PDF
PDX 2026-512 (80) E8.003.pdf PDF
PDX 2026-512 (97) T2.253.pdf PDF
PDX 2026-512 (159) G2.202.pdf PDF
PDX 2026-512 (12) S2.200.pdf PDF
PDX 2026-512 (217) G9.112.pdf PDF
PDX 2026-512 (96) T2.252.pdf PDF
PDX 2026-512 (8) S0.003.pdf PDF
PDX 2026-512 (77) E7.001.pdf PDF
PDX 2026-512 (126) G2.063.pdf PDF
PDX 2026-512 (130) G2.073.pdf PDF
PDX 2026-512 (91) T1.253.pdf PDF
PDX 2026-512 (151) G2.162.pdf PDF
PDX 2026-512 (27) S2.353.pdf PDF
PDX 2026-512 (35) S6.111.pdf PDF
PDX 2026-512 (79) E8.002.pdf PDF
PDX 2026-512 (212) G9.107.pdf PDF
PDX 2026-512 (93) T2.153.pdf PDF
PDX 2026-512 (6) S0.001.pdf PDF
PDX 2026-512 (44) E1.240.pdf PDF
PDX 2026-512 (53) E1.753.pdf PDF
PDX 2026-512 (28) S2.370.pdf PDF
PDX 2026-512 (149) G2.160.pdf PDF
PDX 2026-512 (86) E9.005.pdf PDF
PDX 2026-512 (92) T2.100.pdf PDF
PDX 2026-512 (192) G2.341.pdf PDF
PDX 2026-512 (145) G2.143.pdf PDF
PDX 2026-512 (207) G9.102.pdf PDF
PDX 2026-512 (104) G0.003.pdf PDF
PDX 2026-512 (240) G9.135.pdf PDF
PDX 2026-512 (119) G2.040.pdf PDF
PDX 2026-512 (185) G2.303.pdf PDF
PDX 2026-512 (141) G2.133.pdf PDF
Show 40 more

Latest 50 of 247 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/

4" 1/

2" 1"

2"

G R

AP

H

IC

S

C

AL

E-

FO

R R

EF

ER

EN

C

E O

N

LY

DRAWING SCALE IS REDUCED 50% WHEN SHEET SIZE IS 17" x 22".

SUBMITTED BY

DESIGNED BY

DRAWN BY

CHECKED BY

DATE

SHEET NO.

DRAWING NO.

TYPE

DISC. SHT. NO.

EAN PAN

NO. DATE BY REVISIONS APP

C

AN

Y O

U S

EE

T

H E

AI

R

PL

AN

ES

T H

E

AD

JA

C

EN

T

SA

M

PL

ES

S H

O W

T H

R

EE

D

IF

FE

R

EN

T

LE

VE

LS

O

F

SH

AD

IN

G

SE

TT

IN

G

S

FO

R V

IE

W

IN

G

A N

D P

R

IN

TI

N

G D

R

AW

IN

G

C O

N

TE

N T

AR

E

O

PT

IM

IZ

ED

W

H

EN

A

LL

T H

R

EE

P

LA

N

ES

A R

E

VI

SI

BL

E.

T

H

IS

G U

ID

AN

C E

IS

P

R O

VI

D

ED

F

O R

R

EF

ER

EN

C E

O N

LY

bl ac k gr ay gr ay lig ht da rk

NO. DATE BY REVISIONS APP

IF ELECTRONIC SIGNATURE IS BROKEN OR MISSING - THIS IS NOT A LEGAL DRAWING

TYPE

D R

AW

IN

G S

C

AL

E

IS

R

ED

U C

ED

0% W

H

EN

S H

EE

T

SI

ZE

IS

7" x

2"

B▲ A▲ PDX 2026-5122026D004 103101

CD

7/21/2026 11:08:13 AM Autodesk Docs://PDX Moving Walkways, Play Area & Wayfinding Signage/PDX 2026-004-SIGN25.rvt

SIGN DETAILS 10

PORTLAND INTERNATIONAL AIRPORT

G9.110

AUGUST 2026

K. FRY

B. STEVENS

B. STEVENS

JAY OSTLUND

TERMINAL AND CONCOURSES WAYFINDING SIGNAGE

CMB2 - SECTION

SCALE: 1" = 1' - 0"

LE

N

G

TH

O F

V

ER

TI

C

A L

M O

U N

TI

N

G S

U

PP

O R

T

VA

R

IE

S D

EP

EN

D

IN

G O

N C

EI

LI

N G

H

EI

G H

T

ELECTRICAL

CONNECTION TO STRUCTURAL SUPPORT

VARIES PER LOCATION, SEE STRUCTURAL

POWER SUPPLY: CONFIRM COMPATIBILITY

WITH AIRPORT MANAGEMENT SYSTEM.

POWER SUPPLY TO BE LOCATED IN TOP

CABINET (PER SIDE)

CABINET ILLUMINATION: LED 6700K MODULES,

DIMMABLE AND CONNECTED TO LIGHTING

CONTROLLER

INNER MOUNTING PLATE

LIGHT BAR ILLUMINATION: LED PRISM

6500K WHITE MODULES, DIMMABLE AND

CONNECTED TO LIGHTING CONTROLLER

HORIZONTAL ALUMINUM PIPE

MOUNTING PLATE – CONNECTION TO

SIGN CABINET, SPACING AND VERTICAL

CONNECTION BY STRUCTURAL

NOTE:

INCOMING WIRING BY DIVISION 26 ELECTRICAL CONTRACTOR,

SIGN MANUFACTURER TO LOCATE AND PROVIDE DEVICES NOTED.

INCOMING POWER CIRCUIT DISCONNECT,

20 AMP RATED, 120/277V AC

ETC FOUNDRY DMX TO 0-10V CONVERTER

Ground TransportationRestrooms

Baggage ClaimConcourse B C D

CMB2 - ELEVATION

SCALE: 1" = 1' - 0"

2'

0"

1'

0" 1'

0"

3"

13' - 0"

8' - 4"

LE

N

G

TH

O F

V

ER

TI

C

A L

M O

U N

TI

N

G

SU

PP

O

R T

VA

R

IE

S

D

EP

EN

D

IN

G

O N

C

EI

LI

N

G H

EI

G

H T

LIGHT BAR

FABRIC SIGN FACE: WHITE TANSLUCENT

FABRIC SUBSTRATE WITH OPAQUE AND

TRANSLUCENT DIRECT PRINT GRAPHICS

APPLIED WITH UV INKS. ILLUMINATION TO BE

EVEN WITH NO SHADOWS FROM INTERNAL

HARDWARE. BACKGROUND TO BE OPAQUE

AND MATCH PANTONE 2955. COPY AND

GRAPHICS TO BE TRANSLUCENT AND

MATCH PANTONE 7462 AND WHITE. SQUARE

GRAPHIC CONTAINER TO HAVE

4 POINT STROKE TO MATCH PANTONE 2379.

ENTIRE SIGN FACE INTENDED TO BE BACK

ILLUMINATED. FONT: HELVETICA NEUE LT

STD LIGHT CAP HEIGHT 4"

CABINET: (4) 1' - 0" X 13' - 0" X 3 1/2"

SIGNCOMP FRONT LOAD SOFT ALUMINUM

SIGNAGE FRAME PART #3095, PAINTED

PORT WHITE

REMOVABLE END CAP PAINTED PORT WHITE

3" 2" 7" 3"7"7"

2.5" 2.5"

CMB2 - FABRIC FACE PRINTED ALIGNMENT MARKS

SCALE: 1" = 1' - 0"

13' - 2"

3' - 3 1/2" 3' - 3 1/2" 3' - 3 1/2"3' - 3 1/2"

1'

2"

VISIBLE SIGN FACE:

12' - 11" W X 11-1/4" H

PRINTED THIN BORDER LINE TO MATCH

PANTONE 7462. USE FOR PRECISE

ALIGNMENT OF FABRIC WITH SIGN

CABINET DURING INSTALLATION.

13' - 0" W X 1' - 0" H

OVERALL PRINTED FABRIC:

13' - 2" W X 1' - 2" H

COLOR TO MATCH PANTONE 2955

PROVIDE EQUIDISTANT THIN LINES TO

MATCH PANTONE 7462. PRINT 6 TOTAL, 3

ON TOP AND 3 ON BOTTOM EDGE OF

FABRIC FACE. USE FOR PRECISE

ALIGNMENT OF FABRIC WITH SIGN

CABINET DURING INSTALLATION.

Gates D10-D15

Ticketing

Concourse B C E

Concouse B C EGates D10-D15

Ticketing

SCALE: 1" = 1' - 0"

CMB2 - MESSAGE LAYOUTS2

CMB2-013 A

CMB2-013 B

15' - 0" A .F.F.

TO

TO

P O

F SIG

N

CMB2 - MOUNTING CONDITION

SCALE: 1/4" = 1' - 0"

SEE STRUCTURAL

FOR ABOVE CEILING

ATTACHMENT

NOTE:

SEE FABRICATION DETAILS FOR CM2

G9.103

G9.104

G9.104

G9.105

File details come from the government source that posted it. Updated .