2026-0827_Renovation_for_Orange_Beach_Medical_Center_South_-_Drawings.pdf
PDF 14 MB Posted
- Attached to
- Renovation for Orange Beach Medical Center South
- Solicitation number
- 2026-0827
- Issued by
- Baldwin County, Oneonta City, Alabama
About this file
Renovation for Orange Beach Medical Center South - Architectural Drawings
This is a comprehensive set of architectural drawings and specifications for the renovation of the City of Orange Beach's former Finance Building located at 4151 Orange Beach Boulevard, Orange Beach, Alabama 36561, to be converted into Medical Center South. The project involves extensive renovations including interior layout reconfiguration with 45 rooms and spaces such as exam rooms, labs, restrooms, administrative offices, and support facilities. The scope encompasses architectural modifications with new wall framing, structural work, plumbing system installation, HVAC system design, and electrical systems, with all work to comply with 2017 ICC A117.1 accessibility standards and ADA requirements. The design includes exterior modifications with new Hardie board and batten siding, standing seam metal roofing, new windows and doors, and landscape improvements. The project is designed by McCullough Architecture, Inc. with structural engineering by Bethel Engineering, mechanical and plumbing systems by GSE Consulting Engineers, and electrical design by H.M. Yonge and Associates. Construction documents are dated July 7, 2026, with detailed floor plans, elevations, sections, and specifications for all building systems and finishes.
The bid specifications require a firm, net, delivered pricing that includes all labor and materials necessary to complete the project, with the City of Orange Beach qualifying as tax-exempt. The contractor must secure and pay for all necessary permits and inspections, field-verify all existing dimensions and site conditions before material purchase or construction commencement, and comply with OSHA requirements and all applicable building codes. Construction shall follow manufacturer specifications and industry standards, with the contractor responsible for erosion control, site cleanup, and maintaining clean finished spaces. Deviations from drawings require written architect approval, and all conflicting or unclear specifications shall be interpreted as requiring the more expensive construction method unless prior written clarification is obtained from the architect. The project requires coordination between multiple trades, scheduling of work phases with the owner at least 14 days in advance, and utility coordination to avoid conflicts with existing underground infrastructure.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET INDEX
CONTACT INFORMATION
ARCHITECT
McCOLLOUGH ARCHITECTURE, INC.
CONTACT: STED McCOLLOUGH
MAIN STREET, SUITE 201F
ORANGE BEACH, ALABAMA 36561
PHONE: 251-968-7222
MECHANICAL, PLUMBING, &
ELECTRICAL ENGINEERING
GSE CONSULTING ENGINEERS
600 AZALEA RD.
MOBILE, AL 36609
251-460-4646
T1.1 TITLE SHEET, SHEET INDEX & GENERAL NOTES
LS1.1 LIFE SAFETY PLAN - CODE DATA
GENERAL
GENERAL NOTES:
1. ALL PRODUCTS, MATERIALS, AND CONSTRUCTION SHALL BE
PROVIDED AND/OR INSTALLED IN STRICT ACCORDANCE WITH THE
MANUFACTURERS SPECIFICATIONS, GUIDELINES, AND/OR INDUSTRY
STANDARDS.
2. THE INTENT OF THESE DRAWINGS IS TO PROVIDE THE BUILDER WITH
GENERAL GUIDELINES FOR THE SOUND CONSTRUCTION OF THE
STRUCTURE INDICATED WITHIN. DEVIATIONS FROM THESE DRAWINGS
ARE THE BUILDERS RISK UNLESS APPROVED IN WRITING OR WITH
SUPPLEMENTAL DRAWINGS FROM THE ARCHITECT.
3. IT IS RECOMMENDED THAT THE SERVICES OF A REGISTERED LAND
SURVEYOR BE EMPLOYED FOR THE PROPER PLACEMENT OF THE
STRUCTURE IN RELATION TO PROPERTY LINES, SETBACK LINES,
EASEMENTS, ETC.
4. CONTRACTOR TO SECURE AND PAY FOR ALL NECESSARY FEES AND
PERMITS FOR CONSTRUCTION, ELECTRICAL, AND PLUMBING
INSPECTORS, FINISH FLOOR ELEVATIONS, ETC.
5. DO NOT SCALE DRAWINGS!!! DIMENSIONS OR LINEAR MEASUREMENTS
TAKE PRECEDENCE OVER NOTED DIMENSIONS.
6. DIMENSIONS INDICATED ON DRAWINGS ARE TO FACE OF STUDS (U.N.O.).
7. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS INDICATED
WITHIN THESE DOCUMENTS AND SHALL NOTIFY THE ARCHITECT OF
ANY VARIATION PRIOR TO THE PURCHASING OF ANY MATERIALS,
STARTING FABRICATION, OR BEGINNING CONSTRUCTION
8. PROVIDE TEMPORARY SETTLING BASINS, HAY BALES, AND OTHER
METHODS AS APPROPRIATE TO FILTER WATER AT ALL AREAS WHERE
STORM WATER LEAVES THE PROJECT. CLEAN UP ALL SOIL WHICH
FLOWS OFF SITE AT THE END OF THE DAY.
9. ALL EXISTING SITE CONDITIONS ARE TO BE VERIFIED BY CONTRACTOR
BEFORE START OF CONSTRUCTION.
10. PROVIDE CHEMICAL BARRIER TO BUILDING FROM SUBTERRANEAN
TERMITE ATTACK.
11. NO QUALIFYING STATEMENTS OR EXCEPTIONS TO PLANS OR NOTES
TO BE ALLOWED.
12. ALL WORK RELATED DEBRIS SHALL BE REMOVED FROM THE SITE
REGULARLY AND PROPERLY.
13. THE CONTRACTOR SHALL LEAVE ALL AREAS AND FINISHED SPACES IN
A CLEAN AND ACCEPTABLE CONDITION AT THE PROJECT COMPLETION.
14. ALL CONTRACTORS AND SUBCONTRACTORS SHALL COMPLY w/ OSHA
REQUIREMENTS.
15. ALL NEW CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE BUILDING
CODES AND RESTRICTIVE ORDINANCES FOR CONSTRUCTION, ELECTRICAL,
PLUMBING, AND MECHANICAL.
16. SHOULD A CONFLICT, INCONSISTENCY, AMBIGUITY, OMISSION OR ERROR
OCCUR WITHIN OR BETWEEN THE DRAWINGS AND/OR SPECIFICATIONS, A
BIDDER WILL BE DEEMED TO HAVE BASED THE BID ON THE MORE
EXPENSIVE WAY OF PROVIDING THE WORK INVOLVED. AN ITEM SHOWN
ANYWHERE IN THE BID DOCUMENTS, REGARDLESS OF DISCIPLINE AND
LOCATION IN THE DOCUMENTS, MUST BE CONSIDERED PART OF THE WORK
AND A REASONABLE AND PROFESSIONAL COST MUST BE INCLUDED IN THE
BID. THE SOLE EXCEPTION TO THIS PROVISION IS THAT A BIDDER, PRIOR
TO SUBMISSION OF HIS BID, HAS ASKED FOR AND OBTAINED A WRITTEN
DECISION OR CLARIFICATION FROM THE DESIGNER AS TO THE METHOD,
MATERIALS OR EQUIPMENT WHICH WILL BE REQUIRED TO PERFORM THE
WORK IN QUESTION.
17. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL REVIEW THE
CONSTRUCTION DOCUMENTS, COMPARE REQUIREMENTS FOR EACH TRADE,
AND REFER ANY CONFLICTS TO ARCHITECT BEFORE BEGINNING
CONSTRUCTION.
18. IF DISCREPANCIES OCCUR BETWEEN THE DRAWINGS AND THE
SPECIFICATIONS, THE OBVIOUS CORRECT INTENT SHALL GOVERN. REFER
ALL OTHER UNCERTAINTIES TO THE ARCHITECT FOR RESOLUTION.
9'-0"
A5.1
SHEET NUMBER
ON OUTSIDE IF MULTIPLE
DETAIL NUMBER-NOTE NUMBER
A4.2
BB
IDENTIFICATION
SECTION
LOCATION
SECTION
DOOR TYPE
INTERIOR ELEVATION
SECTION CUT
ELEVATION MARKER
LOCATION MARKER
SEA LEVEL
HEIGHT ABOVE MEAN
SHEET NUMBER
A
B
A DIRECTIONS W/ ONE TAG
VIEW DIRECTION
VIEW DIRECTION
PLAN MARKER/TAG LEGEND
WINDOW TYPE
ARCHITECTURAL
D1.1 DEMOLITION FLOOR PLAN
D1.2 DEMOLITION ROOF PLAN
D3.1 DEMOLITION ELEVATIONS
D3.2 DEMOLITION ELEVATIONS
A1.0 NOTES, LEGENDS & ADA DETAILS
A1.1 ARCHITECTURAL FLOOR PLAN
A1.2 ARCHITECTURAL CEILING PLAN
A1.3 ARCHITECTURAL ROOF PLAN
A2.1 FINISH/DOOR SCHEDULES - DOOR/STOREFRONT TYPES
A2.2 DOOR & STOREFRONT DETAILS
A3.1 EXTERIOR ELEVATIONS
A3.2 EXTERIOR ELEVATIONS
A4.1 BUILDING SECTIONS
A4.2 SECTIONS
A5.1 ENLARGED PLANS - INTERIOR ELEVATIONS
A5.2 INTERIOR ELEVATIONS
A6.1 ARCHITECTURAL RENDERING
A107
A
2 STOREFRONT TYPE
WALL TYPE
LOUVER TYPE1
AN NEW RENOVATION
FOR
MEDICAL CENTER SOUTH
ORANGE BEACH, AL
PLUMBING, MECHANICAL & ELECTRICAL
P1.1 PLUMBING DEMOLITION PLAN
P2.1 WASTE PIPE NEW WORK FLOOR PLAN
P2.2 WATER PIPE NEW WORK FLOOR PLAN
P3.1 WASTER RISER DIAGRAM
P4.1 PLUMBING SCHEDULES, LEGEND & DETAILS
M1.1 HVAC DEMOLITION FLOOR PLAN
M2.1 HVAC NEW WORK FLOOR PLAN
M3.1 HVAC SCHEDULES, LEGEND & DETAILS
E1.1 ELECTRICAL LEGEND
ED1.1 ELECTRICAL DEMOLITION PLAN
E2.1 ELECTRICAL LIGHTING PLAN
E3.1 ELECTRICAL POWER PLAN
E4.1 ELECTRICAL SYSTEMS PLAN
E5.1 ELECTRICAL DETAILS
E5.2 ELECTRICAL DETAILS
E6.1 ELECTRICAL SCHEDULES
E7.1 ELECTRICAL SPECIFICATIONS
C O P Y R I G H T 2 0 2 6 , M c C O L L O U G H A R C H I T E C T U R E, I N C.
SCALE:
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
T1.1
GENERAL NOTES
TITLE SHEET, SHEET INDEX
2026.07.07
SBM
JAG
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N
STRUCTURAL ENGINEERING
BETHEL ENGINEERING
CONTACT: VINCE LACOSTE
3233 EXECUTIVE PARK CIRCLE
MOBILE, ALABAMA 36606
PHONE: 251-661-4747
STRUCTURAL
S0.0 STRUCTURAL NOTES
S1.0 FOUNDATION PLAN
S2.0 CEILING FRAMING PLAN
S3.0 ROOF FRAMING PLAN
S4.0 SECTIONS & DETAILS
S5.0 SECTIONS & DETAILS
S6.0 SECTIONS & DETAILS
S7.0 SECTIONS & DETAILS
tR ge i het Ar de s r c i t e c
St a
Stedmann B. McCollough bae of A l t a m a
C O P Y R I G H T 2 0 2 6 , M c C O L L O U G H A R C H I T E C T U R E, I N C.
SCALE:
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
LS1.1
CODE DATA
LIFE SAFETY PLAN
1/4" = 1'-0"
2026.07.07
SBM
JAG
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N
LIFE SAFETY PLAN
1/4" = 1'-0"
LEGEND
FEC
DISTANCE IN FEET
EXIT TRAVEL DISTANCE
47'
EXIT SIGN
EMERGENCY LIGHTS
FIRE EXTINGUISHER
DIRECTIONAL
EGRESS LIGHTS
EMER. EMERGENCY 2x4 LIGHT
EMER. EMERGENCY SUSPENDED LED
EMER. EMERGENCY CAN LIGHT
EMERGENCY WALL LIGHTEMER.
E X I T
PROVIDE EMERGENCY
LIGHTING PER ELEC.
DRAWINGS
BUILDING CODE SUMMARY
PROJECT DATA
-CONSTRUCTION TYPE:
-OCCUPANT LOAD
-OCCUPANCY
-EXIT TRAVEL DISTANCE
-FIRE RATED WALLS
-PROVIDED FIRE EXTINGUISHER
-STORIES/SQUARE FOOTAGE ALLOWED
-STORIES/SQUARE FOOTAGE ACTUAL
-REQUIRED/PROVIDED NUMBER OF EXITS
-PROVIDED TOILETS/LAVATORIES
VB, NON-SPRINKLERED
2/9,000 S.F.
B
2/3 <200'
1/5,645 S.F.
38 PEOPLE
NOTE
3/3
B = 5,645/150 = 37.63
-2024 INTERNATIONAL BUILDING CODE
-2024 INTERNATIONAL PLUMBING CODE
-2024 INTERNATIONAL MECHANICAL CODE
-2024 INTERNATIONAL FIRE CODE
-2024 INTERNATIONAL EXISTING BUILDING CODE
-2023 NATIONAL ELECTRIC CODE
NONE REQUIRED
E X I T
E X I T E X I T
E X I T
E X I T E X I T
103'
67'
FE
C
FEC
STORAGE
101 XRAY
EXAM ROOM 5
EXAM ROOM 4
EXAM ROOM 3
EXAM ROOM 2
EXAM ROOM 1
HALL 1
IT ROOM
NURSING STATION
HALL 2
HALL 4 120
HALL 5
HALL 3
LAB
EXAM ROOM 6
STORAGE
RECEPTIONIST 114
LOBBY
MECHANICAL
RESTROOM
EXAM ROOM 13
EXAM ROOM 12
LAB
RESTROOM
RESTROOM
BREAK ROOM
STORAGE
OFFICE 1
OFFICE 4
OFFICE 3
OFFICE 2
MECHANICAL
EXAM ROOM 11
EXAM ROOM 10
EXAM ROOM 9
EXAM ROOM 8
EXAM ROOM 7
CLEAN UTILITY
ROOM
BIOHAZARD
STORAGE
CHECKOUT / BILLING 1
CHECKOUT / BILLING 2
JANITOR
STORAGE
DRAFTSTOPPING WALLS
DRAFT STOP DETAIL
WOOD STUD
WALL TIGHT UP
TO ROOF
8" GYPSUM "TAPED"
5'h x 3'w 1/2" PLYWOOD
PANEL WITH SELF-CLOSING
COMMERCIAL DOOR HINGES
SEAL TIGHT TO
CEILING BELOW
SEAL TIGHT TO
ROOF ABOVE
tR ge i het Ar de s r c i t e c
St a
Stedmann B. McCollough bae of A l t a m a
THIS PROJECT INVOLVES THE COMPREHENSIVE RENOVATION OF AN EXISTING
COMMERCIAL BUILDING, FEATURING A NEW CONSTRUCTION EXPANSION AND
THE COMPLETE DEMOLITION OF THE EXISTING DRIVE-THRU AREA, INCLUDING
ITS CANOPY AND LANES. THE INTERIOR SCOPE REQUIRES THE REMOVAL OF
ALL EXISTING DOORS, WINDOWS, AND CEILING SYSTEMS, UNLESS EXPLICITLY
NOTED OTHERWISE IN THE DRAWINGS. FOLLOWING DEMOLITION, THE FACILITY
WILL UNDERGO STRUCTURAL UPDATES AND LAYOUT RECONFIGURATIONS TO
SEAMLESSLY INTEGRATE THE ORIGINAL FOOTPRINT WITH THE NEW ADDITION.
CONTRACTORS MUST STRICTLY REFER TO THE CONSTRUCTION DRAWINGS
FOR ALL DETAILED SPECIFICATIONS, LAYOUTS, AND MATERIAL SCHEDULES
REGARDING THE INSTALLATION OF NEW FLOORING, CEILINGS, WALLS,
WINDOWS AND SYSTEMS. ALL DIMENSIONS AND SITE CONDITIONS MUST BE
FIELD-VERIFIED PRIOR TO COMMENCING DEMOLITION OR ORDERING
MATERIALS.
PROJECT SUMMARY AND GENERAL NOTES
AutoCAD SHX Text N
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
D1.1
FLOOR PLAN
DEMOLITION
1/4" = 1'-0"
2026.07.07
SBM
CLT
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N
DEMOLITION FLOOR PLAN
1/4" = 1'-0"
1. CONTRACTOR SHALL REPORT TO THE OWNER & ARCHITECT IF THERE IS ANY MOLD OR ASBESTOS FOUND DURING
DEMOLITION.
2. THE CONTRACTOR SHALL FOLLOW ALL OSHA, EPA AND LOCAL REGULATIONS REQUIRED FOR DEMOLITION.
3. ALL PERMITS SHALL BE OBTAINED FROM JURISDICTIONAL MUNICIPALITIES PRIOR TO DEMOLITION.
4. ALL DEMOLITION WORK SHALL BE IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE (IBC) STANDARDS
AND CONSTRUCTION PRACTICES.
5. CONTRACTOR SHALL CLEAN UP, REMOVE AND DISPOSE OF ALL DEBRIS AND DISCARDED ITEMS UPON COMPLETION
OF CONSTRUCTION TO BE READY FOR A NEW OCCUPANCY CONDITION.
6. CONTRACTOR SHALL FIELD INSPECT ALL EXISTING ACOUSTICAL CEILING AREAS, ESPECIALLY IN RESTROOMS.
REMOVE AND REPLACE WATER-DAMAGED CEILING TILES. THEN MECHANICAL CONTRACTOR SHALL INVESTIGATE A/C
SYSTEM FOR ANY PROBLEM AND REPAIR TO STOP AND PREVENT ANY FURTHER WATER LEAKING.
7. FOR MEP DEMOLITION PLAN, SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS.
8. IN DEMOLITION PHASE, THE CONTRACTOR SHALL FIELD INVESTIGATE AND COORDINATE WITH MEP ENGINEERS ALL
ELECTRICAL PANELS, ELECTRICAL CONTROL DEVICES, MECHANICAL EQUIPMENT, EXPOSED PIPING, METER PRIOR TO REMOVAL; OTHERWISE, CONTRACTOR SHALL CHECK ALL MEP EQUIPMENT TO ASSURE THEY ARE IN GOOD
CONDITION FOR REUSE.
9. ALL SALVAGE ITEMS SUCH AS LIGHTING FIXTURES, EQUIPMENTS, FURNITURE SHALL BE RETURNED AND STORED PER
OWNER'S INSTRUCTIONS.
10. MEP CONTRACTOR SHALL BE RESPONSIBLE FOR ELECTRICAL POWER, UTILITIES, MECHANICAL SAFETY FOR
CONTRACTOR'S WORKERS DURING DEMOLITION PHASE.
11. THIS DRAWING IS SHOWN FOR GENERAL ITEMS TO BE REMOVED ONLY AND DETAIL ITEMS SHALL FIELD DETERMINED
BY MEP ENGINEERS AND OWNER'S INSTRUCTION.
12. OWNER SHALL HAVE RIGHT OF FIRST REFUSAL FOR ALL EQUIPMENT AND MATERIAL REMOVED DURING DEMOLITION AND WILL PROMPTLY SELECT ITEMS. ALL OTHER DEMOLISHED MATERIALS ARE TO BE REMOVED AND DISPOSED OF
OFFSITE.
13. DURING BID PHASE, CONTRACTOR SHALL CONDUCT A SITE VISIT TO FIELD INSPECT AND VERIFY ALL EXISTING BUILDING CONDITIONS, AND IF NECESSARY, SUBMIT AND R.F.I. TO OWNER OR ENGINEER TO BRING UP ANY
CONFLICT.
14. DAMAGED FLOOR DURING DEMOLITION SHALL BE REPAIRED, PATCHED, AND SEALED TO MATCH EXISTING.
15. ALL EXISTING DRAWINGS IN THIS SET ARE FOR REFERENCE ONLY. CONTRACTOR SHALL FIELD VERIFY PRIOR TO
DEMOLITION OR INSTALLATION.
16. VERIFY LOAD BEARING CONDITIONS PRIOR TO WALL DEMOLITION. PROVIDE COLUMNS/BEAMS AS REQUIRED FOR
STRUCTURAL SUPPORT OF ROOF.
GENERAL DEMOLITION NOTES DEMO PLAN LEGEND
EXISTING WALL TO DEMO
KEYED DEMOLITION NOTES
DEMOLISH EXISTING WALL TO EXTENTS SHOWN.
REMOVE DOOR & FRAME AS SHOWN.
REMOVE WINDOW & TRIM AS SHOWN.
4 REMOVE PLUMBING FIXTURE, CAP OR REROUTE PLUMBING LINES.
EXISTING WALL TO REMAIN
1 1
5 REMOVE EXTERIOR COLUMN WRAP/ FAUX COLUMN
6 REMOVE EXISTING NIGHT DROP
5 5 5
3 3 3
3 3 3
REMOVE ALL EIFS AND
EXISTING PARAPET
CONDITIONS, REFER TO
A3.1 & A3.2 FOR EXTERIOR
SCOPE OF WORK
REMOVE ALL EIFS AND EXISTING
PARAPET CONDITIONS, REFER TO
A3.1 & A3.2 FOR EXTERIOR SCOPE
OF WORK
REMOVE ALL EIFS AND
EXISTING PARAPET
CONDITIONS, REFER TO
A3.1 & A3.2 FOR EXTERIOR
SCOPE OF WORK
REMOVE ALL EIFS AND
EXISTING PARAPET
CONDITIONS, REFER TO
A3.1 & A3.2 FOR EXTERIOR
SCOPE OF WORK
'-0
'-3
'-0
EXISTING COLUMNS
TO REMAIN, TYP.
WINDOW TO REMAIN
WINDOW TO REMAIN
WINDOW TO REMAIN
DOOR TO REMAIN
WINDOW TO REMAIN
DOOR TO REMAIN
ARCH CEILING AND
FURR-DOWN ABOVE
TO REMAIN
ARCH CEILING AND
FURR-DOWN ABOVE
TO REMAIN
3'-5" tR ge i het Ar de s r c i t e c
St a
Stedmann B. McCollough bae of A l t a m a
33'-3 1/2"± (FIELD VERIFY)
'-8
FI
EL
D
V
ER
IF
Y)
'-3
2'-0"± 50'-8"± (FIELD VERIFY EXISTING)
'-7
/4
FI
EL
D
V
ER
IF
Y)
8'-0"±
(FIELD VERIFY EXISTING)
CONTRACTOR TO FIELD VERIFY ALL EXISTING
DIMENSIONS AND CONDITIONS.
7 REMOVE EXISTING GYP. BD. CEILING
DEMOLITION ROOF PLAN
1/4" = 1'-0"
REMOVE PARAPETS
(TYP.)
C O P Y R I G H T 2 0 2 6 , M c C O L L O U G H A R C H I T E C T U R E, I N C.
SCALE:
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
D1.2
ROOF PLAN
DEMOLITION
1/4" = 1'-0"
2026.07.07
SBM
CLT
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N
REMOVE PARAPETS
(TYP.)
REMOVE PARAPETS
(TYP.)
REMOVE PARAPETS
(TYP.)
REMOVE METAL ROOF
PANELS AND
WEATHERPROOFING
TO PLYWOOD.
REPAIR/REPLACE
DAMAGED PLYWOOD.
REMOVE METAL ROOF
PANELS AND
WEATHERPROOFING
TO PLYWOOD.
REPAIR/REPLACE
DAMAGED PLYWOOD.
REMOVE METAL ROOF
PANELS AND
WEATHERPROOFING
TO PLYWOOD.
REPAIR/REPLACE
DAMAGED PLYWOOD.
REMOVE GUTTERS
AND DOWNSPOUTS
REMOVE GUTTERS
AND DOWNSPOUTS
REMOVE GUTTERS
AND DOWNSPOUTS
REMOVE GUTTERS
AND DOWNSPOUTS
REMOVE ROOF PEAK
VENT, TYP.
REMOVE ROOF PEAK
VENT, TYP.
tR ge i het Ar de s r c i t e c
St a
Stedmann B. McCollough bae of A l t a m a
CITY OF ORANGE BEACH
FINANCE DEPARTMENT
The Al Bradley Financial Center
EAST ELEVATION
1/4" = 1'-0"
SOUTH ELEVATION
1/4" = 1'-0"
REMOVE ALL EIFS AND PARAPET
CONDITIONS FOR NEW PAINTED HARDIE
BOARD & BATTEN AND ROOF EXTENSION
@ OLD PARAPET CONDITIONS
REMOVE ALL EIFS AND
PARAPET CONDITIONS
REFER TO D1.2
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL EIFS AND PARAPET
CONDITIONS FOR NEW PAINTED HARDIE
BOARD & BATTEN AND ROOF EXTENSION
@ OLD PARAPET CONDITIONS
REMOVE ALL EIFS & FOAM
AND REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
C O P Y R I G H T 2 0 2 6 , M c C O L L O U G H A R C H I T E C T U R E, I N C.
SCALE:
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
D3.1
ELEVATIONS
DEMOLITION
1/4" = 1'-0"
2026.07.07
SBM
CLT
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N
REMOVE ALL SIGNAGE
REMOVE ALL LOUVERS
REMOVE ALL LOUVERS
KEYED DEMOLITION NOTES
DEMOLISH EXISTING WALL TO EXTENTS SHOWN.
REMOVE DOOR & FRAME AS SHOWN.
REMOVE WINDOW & TRIM AS SHOWN.
4 REMOVE PLUMBING FIXTURE, CAP OR REROUTE PLUMBING LINES.
5 REMOVE EXTERIOR COLUMN WRAP/ FAUX COLUMN
6 REMOVE EXISTING NIGHT DROP
REMOVE ALL
GUTTERS &
DOWNSPOUTS
WINDOW TO REMAIN
REMOVE ALL LOUVERS
WINDOW TO REMAIN
REMOVE ALL LOUVERS
WINDOW TO REMAINWINDOW TO REMAIN
DOOR TO REMAIN
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL LOUVERS
3 3 3
REMOVE ALL LOUVERS
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
COLUMNS TO
REMAIN, TYP.
REMOVE METAL ROOF PANELS
AND WEATHERPROOFING TO
PLYWOOD. REPAIR/REPLACE
DAMAGED PLYWOOD.
REMOVE ROOF PEAK
VENT, TYP.
REMOVE METAL ROOF PANELS
AND WEATHERPROOFING TO
PLYWOOD. REPAIR/REPLACE
DAMAGED PLYWOOD.
REMOVE ROOF PEAK
VENT, TYP.
REMOVE EXISTING EQUIPMENT FROM WALL,
PERFORM WALL WORK, AND REMOUNT ALL
EQUIPMENT TO WALL (ENSURE ALL WALL
PENETRATIONS ARE WATER TIGHT, ALL
EXISTING UNISTRUT TO BE REPLACED WITH NEW
GALVANIZED UNISTRUT, ALL EXISTING BOXES
TO BE RUST CONVERTED AND PAINTED, REPLACE
ANY BOXES WITH THRU-RUST HOLES)
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL LOUVERS
REMOVE METAL ROOF PANELS
AND WEATHERPROOFING TO
PLYWOOD. REPAIR/REPLACE
DAMAGED PLYWOOD.
REMOVE ROOF PEAK
VENT, TYP.
REMOVE ALL EIFS AND PARAPET
CONDITIONS FOR NEW PAINTED HARDIE
BOARD & BATTEN AND ROOF EXTENSION
@ OLD PARAPET CONDITIONS
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL LOUVERS
tR ge i het Ar de s r c i t e c
St a
Stedmann B. McCollough bae of A l t a
WEST ELEVATION
NORTH ELEVATION
1/4" = 1'-0"
REMOVE ALL EIFS AND PARAPET
CONDITIONS FOR NEW PAINTED HARDIE
BOARD & BATTEN AND ROOF
EXTENSION @ OLD PARAPET
CONDITIONS
REMOVE ALL EIFS AND PARAPET CONDITIONS FOR
NEW PAINTED HARDIE BOARD & BATTEN AND ROOF
EXTENSION @ OLD PARAPET CONDITIONS
C O P Y R I G H T 2 0 2 6 , M c C O L L O U G H A R C H I T E C T U R E, I N C.
SCALE:
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
D3.2
ELEVATIONS
DEMOLITION
1/4" = 1'-0"
2026.07.07
SBM
CLT
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N
KEYED DEMOLITION NOTES
DEMOLISH EXISTING WALL TO EXTENTS SHOWN.
REMOVE DOOR & FRAME AS SHOWN.
REMOVE WINDOW & TRIM AS SHOWN.
4 REMOVE PLUMBING FIXTURE, CAP OR REROUTE PLUMBING LINES.
5 REMOVE EXTERIOR COLUMN WRAP/ FAUX COLUMN
6 REMOVE EXISTING NIGHT DROP
REMOVE METAL ROOF PANELS
AND WEATHERPROOFING TO
PLYWOOD. REPAIR/REPLACE
DAMAGED PLYWOOD.
REMOVE ROOF PEAK
VENT, TYP.
REMOVE METAL ROOF PANELS
AND WEATHERPROOFING TO
PLYWOOD. REPAIR/REPLACE
DAMAGED PLYWOOD.
REMOVE ROOF PEAK
VENT, TYP.
REMOVE METAL ROOF PANELS
AND WEATHERPROOFING TO
PLYWOOD. REPAIR/REPLACE
DAMAGED PLYWOOD.
REMOVE ROOF PEAK
VENT, TYP.
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL LOUVERS REMOVE ALL LOUVERS REMOVE ALL LOUVERS REMOVE ALL LOUVERS
REMOVE ALL LOUVERS
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL EIFS AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL
GUTTERS &
DOWNSPOUTS
REMOVE ALL LOUVERS
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL EIFS AND PARAPET
CONDITIONS FOR NEW PAINTED HARDIE
BOARD & BATTEN AND ROOF EXTENSION
@ OLD PARAPET CONDITIONS
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
REMOVE ALL EIFS AND PARAPET
CONDITIONS FOR NEW PAINTED HARDIE
BOARD & BATTEN AND ROOF EXTENSION
@ OLD PARAPET CONDITIONS
REMOVE ALL EIFS & FOAM AND
REPLACE WITH PAINTED
HARDIE BOARD & BATTEN
(TYP)
tR ge i het Ar de s r c i t e c
St a
Stedmann B. McCollough bae of A l t a m in
18 min m in
36 min 6 m in
42 min m in m in
22 min 24 min4 m in
24 min 4 m in
RAMP RUNLANDING
60 min 60 min
60 min m in
AT LEAST AS WIDE AS RAMP RUN
LANDING
LANDING
RAMP RUN
R A M
P R U N
X < 4
1:12 SLOPE
(MAX.)
1:12 SLOPE
(MAX.)
2'-0"
1'-5"
2' -1
0" 3' -6
ADA BAR ACCESS
FOOTREST NOT TO EXTEND
INTO ADA SPACE
KNEE WALL
TYPICAL BAR TOP BEYOND
PROVIDE SUPPORT FOR
TOP AS REQUIRED
MIN.
ADA BAR SEATING
12" m in m ax m ax m ax
20-25" max20" max
10 max m ax m in
10 max
" m ax
" m ax m ax m ax
>10-24 max
/4
/2
/4
/4
" M A X.
4 max
" M
IN
" M
IN
PROTRUDING OBJECTS
ACCESSIBLE DESIGN NOTES: 2017 ICC A117.1 (v. MAY 2024) CHAPTER 3 BUILDING BLOCKS: 303 Changes in Level
303.2 Vertical.Changes in level of 1/4 inch (6.4 mm) maximum in height shall be permitted to be vertical.
303.3 Beveled.Changes in level greater than 1/4 inch (6.4 mm) in height and not more than 1/2 inch (13 mm) maximum in height shall be beveled with a slope not steeper than 1:2.
303.4 Ramps.Changes in level greater than 1/2 inch (13 mm) in height shall be by a ramp complying with Section 405 or by a curb ramp complying with Section 406.
/4
/2
" 21
303.2 303.3 (A) 303.3 (B)
CHAPTER 3 BUILDING BLOCKS: 304 Turning Space
304.3.1.1 CIRCULAR SPACE New buildings and facilities. In new buildings and facilities, the turning space shall be a circular space with a 67-inch (1700 mm) minimum diameter.
304.3.1.1.1 Overlap. Turning spaces shall be permitted to
include knee and toe clearance complying with Section 306.
Where the turning space includes knee and toe clearances under an obstruction, the overlap shall comply with all of the following: 1.
The depth of the overlap shall not be more than 10 inches (255 mm), and2. The depth shall not exceed the depth of the knee and toe clearances provided, and3. The overlap shall be permitted only within the turning circle area shown shaded in Figure 304.3.1.1.
304.3.1.2 EXISTING BUILDINGS AND FACILITIES. In existing
buildings and facilities, the turning space shall be a circular space with a 60-inch (1525 mm) minimum diameter.
304.3.2.1 T- SHAPED SPACE New buildings and facilities. In new buildings and facilities, the turning space shall be a T–shaped space complying with one of the following:1. A T-shaped space, clear of obstruction, that fits within an area 68 inches (1725 mm) wide and 60 inches (1525 mm) deep, with two arms and one base that are all 36 inches (915 mm) minimum in width. Each arm shall extend 16 inches (405 mm) minimum from each side of the base located opposite the other, and the base shall extend 24 inches (610 mm) minimum from the arms. At the intersection of each arm and the base, the interior corners shall be chamfered for 8 inches (205 mm) minimum along both the arm and along the base.2. A T-shaped space, clear of obstruction, that fits within an area 64 inches (1625 mm) wide and 60 inches (1525 mm) deep, with two arms 38 inches (965 mm) minimum in width and a base 42 inches (1065 mm) minimum in width. Each arm shall extend 11 inches (280 mm) minimum from each side of the base, located opposite the other, and the base shall extend 22 inches (560 mm) minimum from each arm.3. A T-shaped space, clear of obstruction, 64 inches (1625 mm) wide and 60 inches (1525 mm) deep, with two arms and one base 40 inches (1015 mm) minimum in width. Each arm shall extend 12 inches (305 mm) minimum from each side of the base and the base shall extend 20 inches (510 mm) minimum from each arm.
304.3.2.2 Existing buildings and facilities. In existing buildings and facilities, the turning space shall be a T-shaped space within a 60-inch (1525 mm) minimum square, with arms and base 36 inches (915 mm) minimum in width. Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction, and the base shall be clear of obstructions 24 inches (610 mm) minimum.
67" MIN
" M
A X
60" MIN
" M
A X
304.3.1.1 304.3.1.2
" m in
" m in
36" min
8"
68"
304.3.2.1(A)
" m in
" m in
42" min
64"
304.3.2.1(B)
OPTION 1 OPTION 2
" m in
" m in
16" 16" 11" min11"min
304.3.2.1(C)
" m in
" m in 60"
304.3.2.2
EXISTING
" m in
12" min12" min
" m in
" m in
40" min
64"
OPTION 3
" m in
12" min12" min 3'-0"
CHAPTER 3 BUILDING BLOCKS: 305 Clear Floor space
305.3.1 New buildings and facilities. In new buildings and
facilities, the clear floor space shall be 52 inches (1320 mm) minimum in length and 30 inches (760 mm) minimum in width.
305.3.2 Existing buildings and facilities.In existing buildings and facilities, the clear floor space shall be 48 inches (1220 mm) minimum in length and 30 inches (760 mm) minimum in width.
" m in
52" min
305.3.1
" m in
48 min
305.3.2
NEW EXISTING
CHAPTER 3 BUILDING BLOCKS: 306 Knee and Toe Clearance
306.1 General.Where space beneath an element is included
as part of the clear floor space at an element, clearance at an element, or a turning space, the space shall comply with Section
306. Additional space shall not be prohibited beneath an element, but shall not be considered as part of the clear floor space or turning space.
306.2.2 Maximum depth.Toe clearance shall be permitted to
extend 25 inches (635 mm) maximum under an element.
306.2.3 Minimum depth.Where toe clearance is required at an
element as part of a clear floor space complying with Section 305, the toe clearance shall extend 17 inches (430 mm) minimum beneath the element.
306.2.4 Additional clearance.Space extending greater than 6
inches (150 mm) beyond the available knee clearance at 9 inches (230 mm) above the floor shall not be considered toe clearance.
306.2.5 Width.Toe clearance shall be 30 inches (760 mm)
minimum in width.
306.3.1 General.Space beneath an element between 9 inches
(230 mm) and 27 inches (685 mm) above the floor shall be considered knee clearance and shall comply with Section 306.3.
17"-25"
6" max
306.2 (A)
8" min
11" min
306.3 (A)
" m in
TOE CLEARANCE KNEE CLEARANCE
CHAPTER 3 BUILDING BLOCKS: 307 Protruding Objects
307.2 Protrusion limits.Objects with
leading edges more than 27 inches (685
mm) and not more than 80 inches (2030
mm) above the floor shall protrude 4 inches (100 mm) maximum horizontally into a circulation path.Exception: Handrails shall be permitted to protrude 41/2 inches (115 mm) maximum.
307.4 Vertical clearance.Vertical
clearance shall be 80 inches (2030 mm) minimum. Rails or other barriers shall be provided where the vertical clearance is less than 80 inches (2030 mm). The leading edge of such rails or barrier shall be located 27 inches (685 mm) maximum above the floor.Exception: Door closers and door stops shall be permitted to be 78 inches (1980 mm) minimum above the floor.
m ax
5 20
X
307.4 REDUCED VERTICAL CLEARANCE
CHAPTER 3 BUILDING BLOCKS: 308 Reach ranges
308.2 Forward reach.
308.2.1 Unobstructed.Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the floor.
308.2.2 Obstructed high reach.Where a high forward reach is
over an obstruction, the clear floor space complying with Section 305 and knee and toe clearance complying with Section 306 shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches (1220 mm) maximum above the floor where the reach depth over the obstruction is 20 inches (510
mm) maximum. The high forward reach shall be 44 inches (1120
mm) maximum above the floor where the reach depth over the obstruction is greater than 20 inches (510 mm) and not more than 25 inches (635 mm) maximum.
308.3 Side reach.
308.3.1 Unobstructed. INSIGHTS Where a clear floor space
complying with Section 305 allows a parallel approach to an element and the edge of the clear floor space is 10 inches (255
mm) maximum from the element, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum above the floor.Exceptions:1. Existing elements that are not altered shall be permitted at 54 inches (1370 mm) maximum above the floor.2. Operable parts on fuel dispensers installed on existing curbs shall be permitted at 54 inches (1370 mm) maximum above the floor.
308.3.2 Obstructed high reach.Where a clear floor space
complying with Section 305 allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum above the floor and the depth of the obstruction shall be 24 inches (610 mm) maximum. The high side reach shall be 48 inches (1220 mm) maximum above the floor for a reach depth of 10 inches (255 mm) maximum. Where the reach depth exceeds 10 inches (255 mm), the high side reach shall be 46 inches (1170
mm) maximum above the floor for a reach depth of 24 inches (610 mm) maximum.
308.2.1
UNOBSTRUCTED FORWARD
REACH
308.2.2 (B)
OBSTRUCTED HIGH
FORWARD REACH
308.2.2 (A)
OBSTRUCTED HIGH
FORWARD REACH
308.3.1
UNOBSTRUCTED SIDE
REACH
308.3.2 (A)
UNOBSTRUCTED SIDE
REACH
308.3.2 (B)
UNOBSTRUCTED SIDE
REACH
CHAPTER 3 BUILDING BLOCKS: 309 Operable Parts
309.2 Clear floor space.A clear floor space complying with
Section 305 shall be provided.
309.3 Height.Operable parts shall be placed within one or
more of the reach ranges specified in Section 308.
309.4 Operation.Operable parts shall be operable with one
hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be
5.0 pounds (22.2 N) maximum.Exception: Gas pump nozzles shall not be required to provide operable parts that have an activating force of 5.0 pounds (22.2 N) maximum.
CHAPTER 4 ACCESSIBLE ROUTES: 402 Accessible Routes
402.2 Components.Accessible routes shall consist of one or
more of the following components: walking surfaces with a running slope not steeper than 1:20, doors and doorways, gates, ramps, curb ramps excluding the flared sides, blended transitions, elevators and platform lifts. All components of an accessible route shall comply with the applicable portions of this standard.
CHAPTER 4 ACCESSIBLE ROUTES: 403 Walking Surfaces
403.3 Slope.The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of a walking surface shall not be steeper than 1:48.
403.5 Clear width. INSIGHTS The clear width of an
accessible route shall comply with Section 403.5.1. 403.5.2,
403.5.3 or 403.5.4 as applicable.
403.5.1 General.The clear width of an interior accessible route shall be 36 inches (915 mm) minimum. The clear width of an exterior accessible route shall be 48 inches (1220 mm) minimum.
Exceptions:
1. In new buildings and facilities, the clear width shall be permitted to be reduced to 32 inches (815 mm) minimum for a length of 24 inches (610 mm) maximum provided the reduced-width segments are separated by segments that are 52 inches (1320 mm) minimum in length and 36 inches (915 mm) minimum in width.
2. In existing buildings and facilities, the clear width shall be permitted to be reduced to 32 inches (815 mm) minimum for a length of 24 inches (610 mm) maximum provided the reduced width segments are separated by segments that are 48 inches (1220 mm) minimum in length and 36 inches (915 mm) minimum in width.
3. The clear width of an exterior accessible route located within seating areas shall be 36 inches (915 mm) minimum.
4. The clear width of an exterior ramp shall comply with Section 405.5.
m in
52 min 24 max m in m in m in
24 max
403.5.1 (A)
CLEAR WIDTH ACCESSIBLE ROUTE -
NEW BLDG. INTERIOR
m in
48 min 24 max m in m in m in
24 max
403.5.1 (C)
CLEAR WIDTH ACCESSIBLE ROUTE -
EXISTING INTERIOR
CHAPTER 4 ACCESSIBLE ROUTES: 404 DOORS, DOORWAYS AND GATES
404.2.2 Clear width.Doorways shall have a clear opening width of 32 inches (815 mm) minimum. Clear opening width of doorways with swinging doors shall be measured between the face of door and stop, with the door open 90 degrees. Openings more than 24 inches (610 mm) in depth at doors and doorways without doors shall provide a clear opening width of 36 inches (915 mm) minimum. There shall be no projections into the clear opening width lower than 34 inches (865 mm) above the floor. Projections into the clear opening width between 34 inches (865 mm) and 80 inches (2030 mm) above the floor shall not exceed 4 inches (100 mm).
Exceptions:
1. Door closers and door stops shall be permitted to be 78 inches (1980
mm) minimum above the floor.
2. In alterations, a projection of 5/8 inch (16 mm) maximum into the required clear opening width shall be permitted for the latch side stop.
404.2.3.2 Swinging doors and gates.Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.3.2.
404.2.6 Door and gate hardware. Handles, pulls, latches, locks and other operable parts on doors and gates shall have a shape that is easy to grasp with one hand and does not require tight grasping, pinching or twisting of the wrist to operate. The operational force to retract latches or disengage devices that hold the door or gate in a closed position shall be as follows:1. Hardware operation by a forward, pushing or pulling motion:
15 pounds (66.7 N) maximum.2. Hardware operation by a rotational motion: 28 inch-pounds (315 N·cm) maximum.
404.2.7.1 Door and gate closers. Door and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door or gate to an open position of 12 degrees shall be 5 seconds minimum.
404.2.8 Door and gate opening force. Fire doors and doors or gates required to be equipped with panic hardware, break away features or other factors requiring higher opening force for safety reasons shall have the minimum opening force allowable in scoping provisions adopted by the appropriate administrative authority. For other doors or gates, the force for pushing or pulling open doors or gates shall be as follows:1. Interior hinged door: 5.0 pounds (22.2 N) maximum.2. Sliding or folding door: 5.0 pounds (22.2 N) maximum.Exception: The force required to retract latch bolts or disengage other devices that hold the door or gate in a closed position shall not apply to panic hardware, delayed egress devices or fire-rated hardware.
32"
404.2.2 (A)
CLEAR WIDTH OF
DOORWAYS -
HINGED
32"
404.2.2 (B)
CLEAR WIDTH OF
DOORWAYS -
SLIDING
32"
404.2.2 (C)
CLEAR WIDTH OF
DOORWAYS -
FOLDING
36"
404.2.2 (D)
CLEAR WIDTH OF
DOORWAYS -
DOORWAYS WITHIN
DOORS
Approach Direction
TYPE OF USE
Door/Gate side Perpendicular to Door
MINIMUM MANEUVERING CLEARANCES
Parallel to Door
TABLE 404.2.3.2 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
from front from front from hinge side from hinge side from hinge side from latch side from latch side
Pull
Pull Pull
Pull
Push
Push
Push
60"
60" 52"
54" 42"
42" 48"
18" 0" 36" 42" 22" 24"
24"
404.2.3.2 (A)
FRONT, PULL SIDE
12 min*
404.2.3.2 (B)
FRONT, PUSH SIDE
(NEW BLDG.)
m in12 min*
404.2.3.2 (C)
FRONT, PUSH SIDE
(EXISTING BLDG.)
*If both closer and latch provided
*If both closer and latch provided
404.2.3.2 (D)
HINGE APPROACH,
PULL SIDE
404.2.3.2 (E)
HINGE APPROACH,
PULL SIDE
404.2.3.2 (F)
HINGE APPROACH,
PUSH SIDE
*48 If both closer and latch provided
404.2.3.2 (G)
LATCH APPROACH,
PULL SIDE
*54 If closer provided
404.2.3.2 (H)
LATCH APPROACH,
PUSH SIDE
*48 If closer provided
1) Add 6" if closer and latch provided.
2) Add 6" if closer provided.
3) Add 12" beyond latch if closer and latch provided.
4) Beyond hinge side
5) In existing bldgs, the dimension perpendicular to the door for the front direction on the push side shall be 48" min.
CHAPTER 4 ACCESSIBLE ROUTES: 405 RAMPS
405.2 Slope.Ramp runs shall have a running slope greater than 1:20 and not steeper than 1:12.Exception: In existing buildings or facilities, ramps shall be permitted to have slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space limitations.
405.5 Clear width.The clear width of a ramp run shall be 36 inches (915
mm) minimum. Handrails and handrail supports that are provided on the ramp run shall not project into the required clear width of the ramp run.Exception:
Within employee work areas, the required clear width of ramps that are a part of common use circulation paths shall be permitted to be decreased by work area equipment provided that the decrease is essential to the function of the work being performed.
405.6 Rise.The rise for any ramp run shall be 30 inches (760 mm) maximum.
405.7 Landings.Ramps shall have landings at the bottom and top of each ramp run. Landings shall comply with Section 405.7.
405.7.1 Slope.Landings shall have a slope not steeper than 1:48 and shall comply with Section 302.
405.7.2 Width.Clear width of landings shall be at least as wide as the widest ramp run leading to the landing.
405.7.3 Length.Landings shall have a clear length of 60 inches (1525 mm) minimum.
405.7 (A)
405.7 (B)
12 min
405.9.1
405.9.2
12 min
C O P Y R I G H T 2 0 2 6 , M c C O L L O U G H A R C H I T E C T U R E, I N C.
SCALE:
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
A1.0
& ADA DETAILS
NOTES, LEGENDS
AS NOTED
2026.07.07
SBM
JAG
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N tR ge i het Ar de s r c i t e c
St a
Stedmann B. McCollough bae of A l t a
SA
SA
N
SA
N
SA
N
SA
N
SAN. SAN.
SAN.
SA
N
SA
N
SAN.
SA
N
SA
N
SA
N
SA
N
SA
N
SAN.
SAN.
SAN.
SA
N
SA
N
SAN.
SAN.
SAN.
SA
N
SA
N
SA
N
SA
N
SAN.
SAN.
C O P Y R I G H T 2 0 2 6 , M c C O L L O U G H A R C H I T E C T U R E, I N C.
SCALE:
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
A1.1
FLOOR PLAN
ARCHITECTURAL
1/4" = 1'-0"
2026.07.07
SBM
CLT/JAG
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N
ARCHITECTURAL FLOOR PLAN
1/4" = 1'-0"
STORAGE
XRAY
EXAM ROOM 5 104
EXAM ROOM 4
EXAM ROOM 3
EXAM ROOM 2
EXAM ROOM 1
HALL 1
IT ROOM
NURSING STATION
HALL 2
HALL 4
HALL 5
HALL 3
LAB
EXAM ROOM 6
STORAGE
RECEPTIONIST 114
LOBBY
MECHANICAL
RESTROOM
EXAM ROOM 13
EXAM ROOM 12
LAB
RESTROOM
RESTROOM
BREAK ROOM
STORAGE
OFFICE 1
OFFICE 4
OFFICE 3
OFFICE 2
MECHANICAL
EXAM ROOM 11
EXAM ROOM 10
EXAM ROOM 9
EXAM ROOM 8
EXAM ROOM 7
CLEAN UTILITY
ROOM
BIOHAZARD
STORAGE
CHECKOUT / BILLING 1
CHECKOUT / BILLING 2
JANITOR
STORAGE
17'-3 1/2" 18'-8" 10'-2" 9'-10" 9'-10" 9'-10" 10'-4"
'-8
'-8
'-4
'-4
'-3
'-8
'-9
4'-6"
6'-6" 6'-4" 10'-0 1/2" 9'-9"
6'-2" 3'-6 1/2" 11 1/2"
3'-0" 2'-10" 5'-4" 7'-0" 4'-6" 13'-2" 4'-10"
CL
4'-11 1/2" 9'-4" 9'-4" 9'-0" 9'-4" 6'-0" 11'-6" 18'-0"
7'-11 1/2" 8'-4" 8'-4" 8'-0"
4'-2" 3'-6 1/2" 12'-1 1/2" 7'-0" 2'-10" 1'-8" 4'-8"
7'-1 1/2" 8'-4" 8'-6" 4'-4" 6'-4" 7'-0" 5'-10" 8'-4" 8'-6"
'-5
'-4
'-1
'-0
'-8
'-2
'-6
'-4
'-6
/2
'-1
/2
'-0
'-0
'-4
'-9
/2
'-6
/2
'-0
'-4
'-0
'-0
'-4
'-4
'-4
'-8
'-8
'-8
'-1
HARDIE BOARD & BATTEN OVER FLUID
APPLIED WEATHER BARRIER OVER
APA RATED 5/8" PLYWOOD SHEATHING
OVER 2x6 WOOD STUD WALLS
PASS-THRU
CABINET
TRANSACTION
WINDOW
TRANSACTION
WINDOW
WALLS & DOOR BUILT
TO SPECIFICATIONS OF
XRAY CONSULTANTLOCATE NEW WALLS TO
ENCLOSE EXISTING COLUMNS
REUSE EXISTING
8'-8" DOOR HERE
REUSE EXISTING
8'-8" DOOR HERE
INFILL OPENING WITH HARDIE BOARD
& BATTEN OVER FLUID APPLIED
WEATHER BARRIER OVER APA RATED
5/8" PLYWOOD SHEATHING OVER 2x6
WOOD STUD WALLS
REMOVE EXISTING STUCCO
EXTERIOR FINISH AND FOAM,
INSTALL NEW HARDIE BOARD &
BATTEN OVER FLUID APPLIED
WEATHER BARRIER OVER EXISTING
PLYWOOD SHEATHING OVER
EXISTING WOOD STUD WALLS
HARDIE BOARD & BATTEN OVER
FLUID APPLIED WEATHER BARRIER
OVER APA RATED 5/8" PLYWOOD
SHEATHING OVER 2x6 WOOD STUD
WALLS
HARDIE BOARD & BATTEN OVER
FLUID APPLIED WEATHER BARRIER
OVER APA RATED 5/8" PLYWOOD
SHEATHING OVER 2x6 WOOD STUD
WALLS
INFILL OPENING WITH HARDIE
BOARD & BATTEN OVER FLUID
APPLIED WEATHER BARRIER OVER
APA RATED 5/8" PLYWOOD
SHEATHING OVER 2x6 WOOD STUD
WALLS
INFILL OPENING WITH HARDIE BOARD
& BATTEN OVER FLUID APPLIED
WEATHER BARRIER OVER APA RATED
5/8" PLYWOOD SHEATHING OVER 2x6
WOOD STUD WALLS
REMOVE EXISTING STUCCO EXTERIOR
FINISH AND FOAM, INSTALL NEW HARDIE
BOARD & BATTEN OVER FLUID APPLIED
WEATHER BARRIER OVER EXISTING
PLYWOOD SHEATHING OVER EXISTING
WOOD STUD WALLS
PROVIDE HI-LO ADA AND NON-ADA
WATER FOUNTAIN (NON-ADA TO
INCLUDE BOTTLE FILLER)
EXACT REQUIREMENTS FOR XRAY
ROOM DESIGN AND FUNCTION
PER XRAY CONSULTANT
4'-2"
'-2
42" TALL LOW
WALL W/ PAINTED
WOOD TOP CAP
XRAY EQUIPMENT
REQUIRES 3PHASE
POWER
MULTIPLE 120V & 240V
LAB EQUIP. (FRIDGE,
CENTRIFUGE, ETC.)
(SEE ELEC.)
LABCORP
GENERAL NOTES:
1) ALL SINK LOCATIONS REQUIRE PAPER
TOWEL DISPENSERS & SOAP DISPENSERS
2) ALL EXTERIOR WALLS TO RECEIVE R-19
UN-FACED BATT CAVITY INSULATION
3) ALL CEILINGS TO RECEIVE R-38 UN-FACED
BATT ATTIC INSULATION
4) ALL INTERIOR WALLS TO RECEIVE
UN-FACED BATT CAVITY INSULATION (R-19
IN 2x6 WALLS & R-13 IN 2x4 WALLS)
5) ALL CEILING MOUNTED LIGHT FIXTURES TO
BE RATED FOR INSULATION CONTACT
SAN. HAND SANITIZER STATION
FRIDGE
'-0
'-0
'-0
'-0
'-6
'-8
'-6
'-0
'-0
'-0
'-0
1'-0"7'-0"
MOP
103 104 105 106 107
114A
145144
140139138
136A
136 135 134 133
127 126128129130131 125 119 117 116
EX
EX
A A5.1
MULTIPLE 120V & 240V
LAB EQUIP. (MICROSCOPE,
URINALYSIS, FRIDGE,
AUTOCLAVE, ETC.)
B A5.1
A5.16
A5.18
A5.1
A5.1
A5.2
12 (OPP.)
A5.1 5
A5.1
4 (TYP.)
A5.1
A5.2
A5.2
A5.2
19 (OPP.)
A5.214
CLINIC LAB
A5.2 17
'-8
1 11
11 1 1
1 1
1 1
1 1 1 1
1 1 1
1 1
1 1
4'-7 1/2"6'-1 1/2"
4'-7 1/2"6'-1 1/2"
1'-0"
CL
LEGEND
2x6 WOOD STUD WALL @ 16" O.C.
2x4 WOOD STUD WALL @ 16" O.C.
EXISTING WALL TO REMAIN
· ALL EXTERIOR WALLS TO RECEIVE R-19 UNFACED
BATT INSULATION.
· ALL 2x4 INTERIOR WALLS TO RECEIVE R-13
UNFACED BATT INSULATION.
· ALL 2x6 INTERIOR WALLS TO RECEIVE R-19
UNFACED BATT INSULATION.
2x8 WOOD STUD WALL @ 16" O.C.
SIM
SIM
EXISTING WALLS
TO REMAIN
EXISTING WALLS
TO REMAIN
EXISTING WALLS
TO REMAIN
A-A A4.1
A-A A4.1
A5.220
6" DEEP x 36"H. LAMINATED
COUNTERTOP AS SELECTED BY
OWNER, PROVIDE SUPPORT AS
REQUIRED
A5.2
A5.2
21 (OPP.)
'-0
'-0
B-B A4.1
B-B A4.1
LOCATE NEW WALLS TO
ENCLOSE EXISTING COLUMNS
E X
IS
T
IN
G
E X
IS
T
IN
G
E X
IS
T
IN
G
E X
IS
T
IN
G
6" DEEP x 36"H.
LAMINATED
COUNTERTOP AS
SELECTED BY OWNER
6" DEEP x 36"H. LAMINATED
COUNTERTOP AS SELECTED
BY OWNER
A5.2
FURNITURE BY
OWNER, TYP.
FURNITURE BY
OWNER, TYP.
A4.2
2A4.2 tR ge i het Ar de s r c i t e c
St a
Stedmann B. McCollough bae of A l t a m a
85'-11 1/2" (FIELD VERIFY) 8'-0"
'-8
FI
EL
D V
ER
IF
Y)
7'-0"
'-8
'-0
'-0
CONTRACTOR TO FIELD VERIFY ALL EXISTING
DIMENSIONS AND CONDITIONS.
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
A1.2
CEILING PLAN
ARCHITECTURAL
1/4" = 1'-0"
2026.07.07
SBM
CLT/JAG
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N
ARCHITECTURAL CEILING PLAN
1/4" = 1'-0"
10'-0" 10'-0"
10'-0" 10'-0" 10'-0" 10'-0" 10'-0"
10'-0" 10'-0"10'-0"
10'-0"
10'-0" 10'-0" 10'-0" 10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0" 10'-0" 10'-0"10'-0"10'-0"10'-0"
10'-0" 10'-0" 10'-0" 10'-0"
10'-0"
10'-0"10'-0"10'-0"
±8'-3"
EXISTING
ARCHED CEILING
EX
IS
TI
N
G A
R C
H
ED
C
EI
LI
N
G
±11'-6"
@ SPRING
±8'-3"
±11'-6"
@ SPRING
EXISTING LIGHT
TO REMAIN
EXISTING LIGHT
TO REMAIN
EXISTING LIGHT
TO REMAIN
EXISTING CEILING
TO REMAIN
ALL FINAL LIGHTING LOCATIONS TO
BE COORDINATED WITH THE OWNER.
SWITCHES TO BE MOUNTED A
MAXIMUM OF 48" A.F.F.
REFER TO ELECTRICAL LIGHTING
DRAWINGS FOR LIGHT FIXTURE
TYPES AND LOCATIONS.
10'-0"
LEGEND
CEILING HEIGHT
MOISTURE RESISTANT
GYPSUM BOARD CEILING
2' X 2' ACOUSTICAL TILE
CEILING (EQUAL TO
ARMSTRONG 2x2
TEGULAR EDGE 15/16")
EXISTING ARCHED
CEILING TO REMAIN
REMOVE EXISTING
CEILING, REPLACE WITH
PAINTED HARDIE BOARD
WITH BATTEN @ 4'-0" AS
SHOWN AND PERIMETER
BATTEN
DRAFTSTOPPING WALLS
tR ge i het Ar de s r c i t e c
St a
Stedmann B. McCollough bae of A l t a m a
ARCHITECTURAL ROOF PLAN
PROVIDE NEW STANDING SEAM METAL
ROOF OVER NEW ICE & WATER SHIELD
OVER EXISTING PLYWOOD DECKING
(REPLACE ALL DAMAGED PLYWOOD)
FRAME NEW ROOF AT ENTRY, W/ NEW
STANDING SEAM METAL ROOF OVER
ICE& WATER SHIELD OVER NEW 5/8"
APA RATED PLYWOOD
FRAME NEW PORTION OF ROOF AT
OVERHANG, W/ NEW STANDING SEAM
METAL ROOF OVER ICE& WATER
SHIELD OVER NEW 5/8" APA RATED
PLYWOOD
FRAME NEW PORTION OF ROOF AT
OVERHANG, W/ NEW STANDING SEAM
METAL ROOF OVER ICE& WATER
SHIELD OVER NEW 5/8" APA RATED
PLYWOOD
PROVIDE NEW STANDING SEAM METAL
ROOF OVER NEW ICE & WATER SHIELD
OVER EXISTING PLYWOOD DECKING
(REPLACE ALL DAMAGED PLYWOOD)
1-1/2" PER
FO
O T
SLO
PE
1-1/2" PER
FO
O T
SLO
PE
EX
ISTIN
G
SLO
PE
EX
ISTIN
G
SLO
PE
EXISTING SLOPE
MATCH EXISTING
SLOPE
EXISTING SLOPE
MATCH EXISTING
SLOPE
MATCH EXISTING
SLOPE
EXISTING SLOPE
MATCH EXISTING
SLOPE
EXISTING SLOPE
EX
ISTIN
G
SLO
PE
EX
ISTIN
G
SLO
PE
M A
TC
H
EX
ISTIN
G
SLO
PE
M
A
TC
H
EX
ISTIN
G
SLO
PE
1'-0"
'-6
8'-10"
DASHED LINE REPRESENTS OUTSIDE
FACE OF EXTERIOR WALL OR COLUMN
OR SOFFIT BELOW, TYPICAL
1'-0"
'-6
8"
1'-10" 2'-8"
'-8
1'-8"
C O P Y R I G H T 2 0 2 6 , M c C O L L O U G H A R C H I T E C T U R E, I N C.
SCALE:
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
A1.3
ROOF PLAN
ARCHITECTURAL
1/4" = 1'-0"
2026.07.07
SBM
CLT
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N
NEW LAPPED, NONSOLDERED
SEAM METAL ROOF PANELS WITH
APPLIED LAP SEALANT. LAP
SEALANTS SHALL BE APPLIED IN
ACCORDANCE WITH THE
APPROVED MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
NEW LAPPED, NONSOLDERED
SEAM METAL ROOF PANELS WITH
APPLIED LAP SEALANT. LAP
SEALANTS SHALL BE APPLIED IN
ACCORDANCE WITH THE
APPROVED MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
RIDGE VENT RIDGE VENT RIDGE VENT
R
ID
G E
V
EN
T R
ID
G
E V
EN
T
R
ID
G E
V
EN
T R
ID
G
E V
EN
T
R
ID
G E
V
EN
T
RIDGE VENT
FULL PERIMETER VENTED SOFFIT
FULL PERIMETER VENTED SOFFIT
tR ge i het Ar de s r c i t e c
St a
Stedmann B. McCollough bae of A l t a m a
DS
DS = DOWNSPOUT
(PRE-FINISHED METAL)
DS
DS DS
DS
6" METAL GUTTER
6" METAL GUTTER
6" METAL GUTTER
DS
DS
METAL DOWNSPOUT &
CONCRETE SPLASH BLOCK, TYP.
DS
6" METAL GUTTER
DS
DS
METAL DOWNSPOUT &
CONCRETE SPLASH BLOCK, TYP.
METAL DOWNSPOUT &
CONCRETE SPLASH BLOCK, TYP.
METAL DOWNSPOUT &
CONCRETE SPLASH BLOCK, TYP.
SHEET NO.:
DATE:
REVISION:
DRAWN:
CHECKED:
JOB NO.:
P.O. BOX 6310
36547-6310
PHONE: 251-968-7222
GULF SHORES, ALABAMA
IA
CM C OLLOUGH
RCHITECTURE, NC.
A2.1
DOOR/STOREFRONT TYPES
FINISH/DOOR SCHEDULES
1/4" = 1'-0"
2026.07.07
SBM
JAG
O R
A N
G E
B
EA
C H
B
LV
D O
R A
N G
E B
EA
C
H , A
LA
B
A M
A
PR
EV
IO
U S
O B
F
IN
A N
C E
B U
IL
D
IN
G
M E
D
IC
A L
C E
N
TE
R S
O U
TH
FO
R A
N
EW
R
EN
O V
A
TI
O N
D O
O R
N O
D O
O R
F
IN
IS
H
PA
N
IC
H
D W
E
DOOR SCHEDULE
D O
O R
S
IZ
E
D O
O R
EM
A R
K S
TY
PE
FR
A
M E
TY
PE
D O
O
C
LO
SU
R E
R A
TI
N
G
D O
O R
M A
TE
R
IA
L
1 PAINT 1 -3'0" x 8'0" - YESMETAL
ROOM FINISH SCHEDULE
FINISHNAME
ROOM
FINISHMAT'RL
FLOORS WALLS
BASE
CEILING
NOTESMATERIALS TYPE FINISH HEIGHT
STORAGE
XRAY
EXAM ROOM 5
EXAM ROOM 4
EXAM ROOM 3
EXAM ROOM 2
EXAM ROOM 1
STORAGE
PRE-FINA.C.T.
M.R.GYP.BD. = MOISTURE RESISTANT GYPSUM BOARD
GYP. BD. = GYPSUM BOARD
A.C.T. = 2'x2' ACOUSTICAL CEILING TILE WITH 15/16" PRELUDE GRID
P.T. = PORCELAIN TILE OVER SCHLUTER SYSTEM
C.T. = CERAMIC TILE OVER SCHLUTER SYSTEM
L.V.T. = LUXURY VINYL TILE - WOOD PLANK
S.C. = SEALED CONCRETE
ABBREVIATIONS
WOOD BASE = 5-1/4" DELUXE COLONIAL PRE-PRIMED AND PAINTED BASE
V-GROOVE = 1x6 V-GROOVE TREATED CYPRESS WOOD
E. PAINT = EPOXY PAINT
F.R.P. = FIBER-REINFORCED PLASTIC
S.S. = SCORED/STAINED
C.P.T. = CARPET TILE
RB = RUBBER BASE
1. REFER TO OWNER FOR INTERIOR FINISH SELECTIONS AND COLORS.
2. ALL PAINTED SURFACES SHALL HAVE PRIMER AND TWO FINISH COATS.
3. ALL CORRIDOR FINISHES SHALL BE "CLASS A". ALL OTHER FINISHES CAN BE "CLASS C" MINIMUM.
4. RUBBER BASE TO BE BY TARKETT, REFER TO SPECIFICATIONS.
5. PAINT EXPOSED STRUCTURE.
6. BUILD WALLS IN XRAY ROOM TO XRAY CONSULTANTS SPECIFICATIONS.
7. ALL BASE IN TILED ROOMS TO BE PAINTED PVC.
8. ALL WALL/CEILING PAINT IN TILED ROOMS TO BE EPOXY.
9. ALL TILED ROOMS TO RECEIVE VINYL FACED CEILING TILE.
10. SEE SPECIFICATIONS FOR PAINT COLORS.
FINISH SCHEDULE NOTES
RB GYP. BOARD PAINTL.V.T. PRE-FIN
NMBR
ROOM
HALL 1109
CHECK-OUT/BILLING 1
IT ROOM
NURSING STATION
RECEPTIONIST
LOBBY
MECHANICAL
RESTROOM
EXAM ROOM 13
EXAM ROOM 12
10'-0"
2 PAINT 1 -3'0" x 8'0" - -WOOD102
2 PAINT 1 -3'0" x 8'0" - -WOOD103
2 PAINT 1 -3'0" x 8'0" - -WOOD104
2 PAINT 1 -3'0" x 8'0" - -WOOD105
2 PAINT 1 -3'0" x 8'0" - -WOOD106
2 PAINT 1 -3'0" x 8'0" - -WOOD107
2 PAINT 1 -3'0" x 8'0" - -WOOD108
2 PAINT 1 -3'0" x 8'0" - -WOOD111
2 PAINT 1 -3'0" x 8'0" - -WOOD112
2 PAINT 1 -3'0" x 8'0" - -WOOD113
- - - -EXISTING - --114
- - - -EXISTING - --114A
2 PAINT 1 -3'0" x 8'0" - YESWOOD116
136A
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - YESWOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - YESWOOD
2 PAINT 1 -3'0" x 8'0" - YESWOOD
2 PAINT 1 -3'0" x 8'0" - YESWOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
1 PAINT 1 -3'0" x 8'0" - YESMETAL
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
3 PAINT 1 -(2)3'0" x 8'0" - -METAL
3 PAINT 1 -(2)3'0" x 8'0" - -METAL
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
2 PAINT 1 -3'0" x 8'0" - -WOOD
CHECK-OUT/BILLING 2
HALL 5
LAB (LABCORP)
STORAGE
EXAM ROOM 6
HALL 3
LAB (CLINIC LAB)
RESTROOM
RESTROOM
JANITOR
BREAK ROOM
OFFICE 1
STORAGE
HALL 4
OFFICE 4
OFFICE 3
OFFICE 2
MECHANICAL
STORAGE
EXAM ROOM 11
EXAM ROOM 10
EXAM ROOM 9
HALL 2
BIOHAZARD
CLEAN UTILITY ROOM
EXAM ROOM 8
EXAM ROOM 7
HOLLOW METAL
SEE SCHED.
S
EE
S C
H
ED
U
LE
2"
FINISHED FLOOR
'-0
3'-0"
EXTERIOR
METAL
120 2 PAINT 1 -3'0" x 8'0" - -WOOD
'-0
3'-0"
INTERIOR
SOLID WOOD
SINGLE PANEL
PER XRAY CONSULTANT SPEC.'S
'-0
3'-0"3'-0"
EXTERIOR
METAL
FINISHED FLOOR
FINISHED FLOOR
'-1
10'-0"
'-0
'-1
4'-0"
'-0
" 3 '-0
'-1
2'-0"
INTERIOR INTERIOR INTERIOR
BUILT TO XRAY
CONSULTANT
SPECIFICATIONS
PRE-FINA.C.T.RB GYP. BOARD (NOTE 6) PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PAINTM.R. GYP. BD. 10'-0"
PAINT 10'-0"
PAINT 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
-EXIST.RB GYP. BOARD * PAINTL.V.T. PRE-FIN -
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.TILE PAINTTILE PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.TILE PAINTTILE PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB PAINTS.C. SEALED 10'-0"
PRE-FINA.C.T.RB PAINTS.C. SEALED 10'-0"
PRE-FINA.C.T.RB PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.TILE PAINTTILE PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
PRE-FINA.C.T.RB GYP. BOARD PAINTL.V.T. PRE-FIN 10'-0"
TILE TILEPRE-FIN
TILEPRE-FINTILE
TILE TILE M.R. GYP. BOARD PAINTPRE-FIN
PAINT
PAINT
EX EXISTING TO REMAIN
ALL EXTERIOR DOORS AND WINDOWS TO
BE RATED FOR LARGE MISSILE IMPACT
PAINTED 1x6 TRIM
DOOR TRIM - INTERIOR
PAINTED 1x4 TRIM
PAINTED 1x BULLNOSE
W/ MITERED CORNERS
DOOR TRIM…
This is the start of the file's text. The full file is on GovTribe.