2026 0423 NCSD-Nottawa Roof Replacement.pdf
PDF 11 MB Posted
- Attached to
- Roof Replacement
- Solicitation number
- RFP NOTT 260000001817 2
- Issued by
- Saginaw County, Michigan
About this file
This is an architectural drawing set for a roof replacement project at Nottawa Community School District located at 26438 M-86 in Sturgis, Michigan. The project scope involves the complete removal and replacement of existing roofing systems across two roof areas totaling 11,917 square feet (Roof Area "A": 862 SF and Roof Area "B": 11,055 SF). The bidding and permits deadline is April 23, 2026. The project contact is Jerome Wolff, Superintendent, at 269-467-7153. The existing roofing composition consists of built-up roofing (BUR) systems with perlite cover board, polyisocyanurate insulation, and bituminous base sheets on a 2-inch Tectum roof deck. The new roofing system will utilize a 60-mil fully adhered EPDM roofing membrane with mechanically fastened polyisocyanurate insulation, designed to achieve compliance with the 2021 Michigan Energy Code requiring an average R-value of R-30. The project follows Michigan Rehabilitation Code for Existing Buildings and Michigan Commercial Energy Code, both 2021 editions, with construction type IIB classification for this Group E (Education) facility.
The new roofing system is specified to include a minimum 25-year manufacturer warranty with a 5-year labor warranty covering the complete system including edge metal and all flashings. Work requirements include removal of existing roofing down to the deck, raising existing equipment curbs to maintain warranty requirements, installing new prefinished metal gutters and downspouts, and infilling existing roof penetrations such as skylights and roof drains. The contractor is responsible for field verification of all existing conditions, coordination with the building owner regarding construction scheduling and access, protection of existing paving and landscaping, and coordination of any required utility shutdowns. All mechanical and electrical costs associated with raising existing equipment are the contractor's responsibility. The drawings indicate various existing items to remain, including the wind-driven turbine roof ventilator, boiler flue, and antenna, with some requiring removal and reinstallation to facilitate proper roofing installation and warranty compliance.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
© Ehresman Architects
TTLProject No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Title Sheet
Bidding and Permits: 23 April 2026
Nottawa Community School District 26438 M-86 Sturgis, MI 49091 Contact Name: Jerome Wolff, Superintendent Contact Phone: 269-467-7153
ARCHITECT:
STRUCTURAL ENGINEER:
LOCATION PLAN
NOT TO SCALE
ROOF PLAN
NOT TO SCALE
APPLICABLE CODES:
MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS: 2021 EDITION
MICHIGAN COMMERCIAL ENERGY CODE: 2021 EDITION
ASHRAE 90.1-2019:
USE GROUP:
GROUP E: EDUCATION
CONSTRUCTION TYPE:
CONSTRUCTION TYPE: ASSUMED IIB (II-000 FROM SCHOOL FIRE SAFETY RULES)
TOTAL FLOOR AREA:
ROOF AREA 'A': 862 SF (GROSS ROOF AREA)
ROOF AREA 'B': 11,055 SF (GROSS ROOF AREA)
TOTAL ROOF AREA: 11,917 SF (GROSS FLOOR AREA)
LIST OF DRAWINGS
ARCHITECTURAL DRAWINGS:
TTL TITLE SHEET
A0.00 GENERAL INFORMATION
A0.50 MANUFACTURER'S ROOFING DETAILS
A0.51 MANUFACTURER'S ROOFING DETAILS
A0.52 MANUFACTURER'S ROOFING DETAILS
A0.60 REPRESENTATIVE PHOTOGRAPHS
A0.61 REPRESENTATIVE PHOTOGRAPHS
A0.62 REPRESENTATIVE PHOTOGRAPHS
A0.63 REPRESENTATIVE PHOTOGRAPHS
A1.50 ROOF REMOVALS PLAN
A2.50 ROOF PLAN
A9.10 SECTIONS & DETAILS
DEFERRED SUBMITTALS:
PER SECTION 107.3.4.1, ANY REQUIRED SUBMITTALS WILL BE SUBMITTED TO THE AUTHORITY HAVING JURISDICTION BY THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE ASSUMING THE
DUTIES OF CONSTRUCTION SUPERVISION AT THE APPROPRIATE TIME.
DEFERRED SUBMITTALS:
1. NONE
MANCHESTER COMMUNITY SCHOOL DISTRICT
NOTTAWA COMMUNITY SCHOOL
26438 M-86, Sturgis, MI 49091 Roof Replacement
Nottawa Community School 26438 M-86 Sturgis, MI 49091
AVERAGE R-VALUE:
ROOF AREA 'A': R-VALUE = 30.4 AVERAGE
ROOF AREA 'B': R-VALUE = 37.1 AVERAGE
Location of Work (Represented by shade)
LINE OF WALL
8"
CLEAR
MIN
1'-6"
MIN
2'- 29 16
17"-19"(MIN-MAX)
(DIM. TO TOP OF SEAT)
VARIES
(B.F./STANDARD HT)
(BELOW)
DUPLEX OUTLET
(ABOVE)
FIRE ALARM
PULL BOX
1'- 6"
BO
T.
OF
OU
TL
ET
HOOKS
TYPICAL MOUNTING HEIGHTS
SOAP
DISPENSER
" M
IN
2'-
" M
AX
SHOWERFIXTURES
PLUMBING
1'-6" 22" 21 2"
MAX
BARRIER FREE
LAVATORY
WATER CLOSET
LINE OF WALL
1'-6"
MIN
FIXTURES
PLUMBING
OR STALL
LINE OF WALL
16"-1'-6"
17-19" AMBULATORY
BARRIER FREE
4'- 0"
MA
XI
MU
M
15" A.F.F. MINIMUM
ITEMS
SENIOR HOUSING
24" A.F.F. @
ELECTRICAL
SWITCH
LIGHT
48" A.F.F. MAXIMUM
ABBREVIATIONS
6'- 0"
15" A.F.F. MINIMUM
7'- 0"
VA
RI
ES
BY
G
RA
DE
LE
VE
L
ITEMS
GENERAL
ROD
48" A.F.F. MAXIMUM
5'- 4"
CURTAIN
SHOWER
3'- 4"
ACCESSORIES
TOILET ROOM
15" A.F.F. MINIMUM
SOAP
DISH
48" A.F.F. MAXIMUM
SHEET IDENTIFICATION NUMBER
B.F. CONTROLS ARE
OR ADJUSTABLE SPRAY
HOSE WITH HAND HELD
" M
IN
2'-
" M
AX1'-3"
MIN 33
-3
'-0
TO
T
OP39
"-4
1"
" M
IN
2'-
" M
AX
WASH FOUNTAINWASH FOUNTAIN
WALL MOUNTED
2'-
" M
AX
VANITY URINAL
2'-
" M
AX
WALL MOUNTED
TO BE MOUNTED 33" OR 36" A.F.F. TO
NEAR SINKS IN B.F. TOILET ROOMS
NOTE: ANY ELECTRICAL OUTLET
2'-6"
B.F. MIN 1'-6"
OBSTRUCTION
LINE OF
MI
N.
LINE OF WALL
MOP STRIP
AND SHELF
6'- 0"
PLAQUE
5'- 0"
SIGNAGE
URINAL SCREEN
OR PARTITION
LINE OF WALL
1'-5" (B.F. MIN)
19" (B.F. MAX)
FOLDED
POSITION
SHOWER SEATTOILET PAPER
3" MAX
LINE OF WALL
HOLDER
1'-6" 1'-6"
BARRIER FREE BARRIER FREE
39"-41"
GRAB BAR
1'- 6"
LIGHT SWITCH
OUTLET WITH
ELECTRIC DUPLEX,
TELEPHONE, OR T.V.
3'- 6"
(M
AX
IM
UM
THERMOSTAT
BUTTONS
ELEVATOR
PUSH
CONTROLS 7'-
4"
(O R
AS
N
OT
ED
7'- 4"
(O R
AS
N
OT
ED
CLOCK
SPEAKER
WALL
1'-3"
MAX
6'- 0"
6'- 4"
(S
TA
ND
AR
D)
@ B.F. BATHTUB
OFFSET VALVES
LINE OF WALL
3'- 315 16
(S
TA
ND
AR
D)
SHOWER HEAD
AND VALVESURINALURINAL
GRAB BAR
LINE OF WALL
OR PARTITION
BARRIER FREE
3'- 79 16
MA
X)
1'- 5"
MA
X 2'-
0"4'- 29 16
MA
X)
STANDARD
HAND HELD
ELECTRICAL OUTLET
SHOWER HEAD
AND CONTROLS
(SEE NOTE BELOW)
BARRIER FREE
4'- 0"
MA
X
3'- 2"
MI
N
5"
WALL C.O.
THIS AREA
MOUNTED WITHIN
4'- 0"
M
AX
IM
UM
TO
M
AI
N
SW
IT
CH6'-
8"
ELECTRIC
OR PANEL PANEL
B.F. ELECTRIC
LINE OF WALL
UNIT ON BAR
59" MIN. LENGTH
DOOR IDENTIFICATIONROOM NAME AND NUMBER
OR NUMBER FOR EXISTING CONSTRUCTION
COLUMN IDENTIFICATION LETTER
OR NUMBER FOR NEW CONSTRUCTION
COLUMN IDENTIFICATION LETTER
COLUMN INDICATION
LINE OF
WALL BASE
A
C.O. COVER
NAME
ROOM
TRUE NORTH
N
NORTH INDICATION
TO REMAIN
DOOR SWING INDICATION
EXISTING DOOR
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE SECTION IS DRAWN)
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE SECTION IS DRAWN)
DOOR INDICATION
NEW DOOR
DOOR SWING INDICATION
MATCH LINE INDICATION
A20
A10 ZONE "A"
ZONE "B"
BE REMOVED
EXISTING DOOR TO
DOOR SWING INDICATION
ZONE "A"
ZONE "B" A20
A10
ONE TREAD DEPTH AT
BOTTOM OF STAIRS ONLY
12" MIN. TYPICAL
HORIZONTAL HANDRAIL
EXTENSION AT BOTTOM
OR TOP OF RAMP AND
TOP OF STAIR
6'- 0"
M
EN
/ 6 4"
W
OM
EN
" C
HI
LD
RE
N (1
2-
" C
HI
LD
RE
N (1
5-
" B .F
DISPENSER
4'- 0"
B.
F.
H
AN
DL
E
HE
IG
HT
SIZE AS NOTED
B.
F.
M
AX
BACKSPLASH
SHELVING
4'- 6"
(S
TD
B.
F.
3'- 0"
ST
AN
DA
RD
1'- 6"
3'-
0" KNOB OR
LEVER (B.F.)
HARDWARE
LC
SHELF
(BELOW)
WALL SLOT
3'- 8"
(ABOVE)
SHELF
3'- 8"
BAR AND
TOWEL TOWEL
BAR
HOOKSPURSE
BARRIER
3'- 8"
3'- 8"
B.F. SHELF
OR FREE DISPENSER
CUP
4'- 6"
MA
XI
MU
M
7'- 0"
S
TA
ND
AR
D
" M
AX
IM
UM
B .F
5'- 0"
1'- 0"
DRYER
HAIR
DRYER
HAND
TISSUE
FACIAL HANDRAIL
2'-10"-38" TO TOP
ABOVE NOSING,
RAMP SURFACE, OR
WALKING SURFACE
END OF RAMP
LINE OF RISER OR
WASTE
RECEPTACLE
DISPENSER
4'- 0"
M
AX
3'- 8"
TO
C
ON
TR
OL
2'- 6"
TO
T
P
DISPENSER
SANITARY
DISPOSAL
NAPKIN
SEATSANITARY
NAPKIN COVER
" M
AX
(N
.T .S
AND WASTE
DISPENSER
RECEPTACLE
DISPENSER
UNIT
MULTIPURPOSE
OR
TOWEL
8"
MIN
TOWEL
MIRROR SIZE AS SPECIFIED OR NOTED
3'- 4"
B.
F.
M
AX
TO
R
EF
L.
SU
RF
AC
E
6'- 0"
B.
F.
M
IN
FULL LENGTH
BARRIER FREE
MIRROR
MIRROR AND
1'- 6"
B.
F.
MA
X
MIRROR AND
TILTED MIRROR
SHELF OR
MIRROR,
LAV
1'-8" B.F.
MIN
4'- 0"
B.
F.
M
AX
3'- 4"
B.
F.
M
AX
TO
R
EF
L.
SU
RF
AC
E
VANITY COUNTER
MIRROR AND
CHANGING
STATION
BABY
VARIES
A20
A20
INDICATES DIRECTION OF VIEW
SECTION IDENTIFICATION NUMBER
(NUMBER ON SHEET WHERE DRAWN OR REFERENCED)
ELEVATION IDENTIFICATION NUMBER
A20
1/4"=1'-0" Elevation Title
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE ELEVATION IS DRAWN)
(SHEET NUMBER WHERE SECTION IS DRAWN)
SHEET IDENTIFICATION NUMBER
ELEVATION INDICATION
A20
ELEVATION IDENTIFICATION
SECTION IDENTIFICATION NUMBER
SECTION LOCATION INDICATION
SECTION IDENTIFICATION NUMBER
(NUMBER ON SHEET WHERE DRAWN OR REFERENCED)
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE SECTION IS DRAWN)
A20
1/4"=1'-0" Section Title
DETAIL IDENTIFICATION NUMBER
(SHEET NUMBER WHERE ENLARGED PLAN IS DRAWN)
SHEET IDENTIFICATION NUMBER
SECTION IDENTIFICATION
A20
REFERENCE SYMBOLS
DETAIL LOCATION INDICATION FOR ENLARGED PLANS
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE DETAIL IS DRAWN)
DETAIL IDENTIFICATION NUMBER
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE DETAIL IS DRAWN)
(NUMBER ON SHEET WHERE DRAWN OR REFERENCED)
DETAIL IDENTIFICATION NUMBER
A20
1/4"=1'-0" Detail Title
DETAIL LOCATION INDICATION
A20
WALL SECTIONS
DETAIL IDENTIFICATION
A20
PLAN SECTIONS
" M
EN
" W
OM
EN
" T
EE
NA
GE
R
" Y
OU
NG
CH
ILD
" B .F
T.P. BELOW GB
MI
N
3'-6"
MIN
12"
MAX
1'-6" (B.F. MIN)
48" (B.F. MAX)
2'-0"
MIN
1'-0"
MIN
& ACCESSORIES
2"
MIN
24" MIN
-3
'-0
TO
T
OP
4'-6" MIN
3'-0" MIN
& ACCESSORIES
MISCELLANEOUS ACCESSORIES, TOILET ACCESSORIES AND FIXTURES
NOTE: MOUNTING HEIGHTS SHOWN ARE PROPOSED FOR ALL ACCESSORIES AND FIXTURES REQUIRED UNLESS OTHERWISE NOTED OR DIMENSIONED ON DRAWINGS FOR SPECIFIC CONDITIONS (B.F. DENOTES BARRIER FREE REQUIREMENTS)
BASE AND UPPER
WALL CABINETS
CHALKBOARD OR
TACKBOARD
DOOR HARDWAREWALL MOUNTED OR
EMERGENCY TELEPHONE
(B.F. FRONT APPROACH)
FIRE EXTINGUISHER CABINET FIRE EXTINGUISHER AND
WALL BRACKET
WALL CABINET COAT ROD AND HAT SHELF
(ABOVE)
BOOT RACK (BELOW)
A
ABV. ABOVE
A.F.F. ABOVE FINISH FLOOR
ACC. ACCESS
ACC. PNL. ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADD. ADDENDUM
ADDN. ADDITION
ADJ. ADJACENT
A/C AIR CONDITIONING
A.C.C. AIR CONDITIONING COMPRESSOR
A.C.C.U. AIR COOLED CONDENSING UNIT
A.H.U. AIR HANDLING UNIT
AL ALIGN
ALT. ALTERNATE
ALUM./AL. ALUMINUM
ANCH. ANCHOR
A.B. ANCHOR BOLT
& AND
ANG./L OR ∠ ANGLE
ANOD. ANODIZED
APT. APARTMENT
APPR. APPROVED
APPROX. APPROXIMATE
ARCH. ARCHITECT/ARCHITECTURAL
A.T.M. AUTOMATIC TELLER MACHINE
ASPH. ASPHALT
ASSY. ASSEMBLY
@ AT
AUTO. AUTOMATIC
AUX. AUXILIARY
AVG. AVERAGE
B
B/B. BACK TO BACK
B.F.P. BACK FLOW PREVENTER
B.D.D. BACK DRAFT DAMPER
B.F. BARRIER FREE
B.B.R BASE BOARD RADIATION
B. PL BASE PLATE
BSMT. BASEMENT
BM BEAM
B/C BACK OF CURB
BRG BEARING
B.M. BENCHMARK
BT BENT
BETW. BETWEEN
BEV. BEVEL
BIT. BITUMINOUS
B.I. BLACK IRON
BLK BLOCK
BLKG BLOCKING
BD BOARD
BLR BOILER
BK. SH. BOOK SHELVES
BOT. BOTTOM
BOT. EL. BOTTOM ELEVATION
BLVD. BOULEVARD
BDRY BOUNDARY
BRKT BRACKET
BTU BRITISH TERMINAL UNIT
BLDG. BUILDING
B.U.R. BUILT UP ROOFING
BUZZ. BUZZER
C
CAB. CABINET
CAP. CAPACITY
CAR. CARPET
C (CONTINUED):
C.T. CAST IRON
C.B. CATCH BASIN
CLG. CEILING
CLG. HT. CEILING HEIGHT
CEM. CEMENT
CEM. PLAS. CEMENT PLASTER
CTR CENTER
℄ CENTER LINE
CER. CERAMIC
C.T. CERAMIC TILE
C.BD. CHALKBOARD
CHAN. OR CHANNEL
CHWE CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CIRCUM. CIRCUMFERENCE
CR. BRK. CIRCUIT BREAKER
CL CLASSROOM
C.O. CLEANOUT
CLR. CLEAR
CL. CLOSER
CW COLD WATER
COL. COLUMN
CO. COMPANY
CA COMPRESSED AIR
CONC. CONCRETE
C.M.U. CONCRETE MASONRY UNITS
CWR COLD WATER RETURN
CWS COLD WATER SUPPLY
COND. CONDUIT
CONF. CONFERENCE
CONST. CONSTRUCTION
C.J. CONTROL JOINT
CONT. CONTINUE/CONTINUOUS
CONTR. CONTRACTOR
C.P. CONTROL PANEL
CONV. CONVECTOR
CRS. COURSE
COV. COVER
COV. PL COVER PLATE
CU. FT CUBIT FEET/CUBIC FOOT
CFV CONTRACTOR FIELD VERIFY
CULV CULVERT
CYL. CYLINDER
CYC. CYCLE(S)
CIRCUM. CIRCUMFERENCE
D
DMPR DAMPER
DMPG DAMPPROOFING
D.L. DEAD LOAD
DB DECIBEL
D. DEEP
DMT. PARTN. DEMOUNTABLE PARTITION
DEPT. DEPARTMENT
DEPR. DEPRESSED
DES. DESIGN
DET. DETAIL
D.E.C. DETROIT EDISON COMPANY
DIAG. DIAGONAL
DIA. OR Ø DIAMETER
DIFF. DIFFUSER
DIM. DIMENSION
DIR. DIRECTION
DISC. DISCONNECT
DW DISHWASHER
DISP. DISPENSER
DIST. DISTANCE
D.P. DISTRIBUTION PANEL
DIV. DIVIDER/DIVISION
D (CONTINUED):
DR. DOOR
D.O. DOOR OPENING
DR. OP DOOR OPERATOR
DBL. DOUBLE
D.H. DOUBLE HUNG
DWL. DOWEL
DN. DOWN
D.S. DOWNSPOUT
DRN. DRAIN
D.T. DRAIN TILE
D.T.C. DRAIN TILE CONNECTOR
DWR DRAWER
DWG DRAWING
D.F. DRINKING FOUNTAIN
DUP DUPLICATE
E
EA EACH
E.F. EACH FACE
E.W. EACH WAY
E EAST
E.I.F.S. EXTERIOR INSULATION FINISH SYSTEM
ELAST. ELASTOMETRIC
ELEC. ELECTRIC/ELECTRICAL
ELEC. CAB. ELECTRICAL CABINET
E.C. ELECTRICAL CONTRACTOR
E.P. ELECTRICAL PANEL
E.W.C. ELECTRIC WATER PANEL
ELEC. OPER. ELECTRICALLY OPERATED
EL. ELEVATION
ELEV. ELEVATOR
EMERG. EMERGENCY
ENCL. ENCLOSURE
ENGR. ENGINEER
ENTR. ENTRANCE
EP. EPOXY
EPDM. ETHYLENE PROPYLENE DIENE MONOMER
EQ. EQUAL
EQUIP. EQUIPMENT
EQUIV. EQUIVALENT
ESC. ESCALATOR
EST. ESTIMATE
EXC. EXCAVATED
EXH. EXHAUST
E.F. EXHAUST FAN
(E) EXISTING
E.C.U. EXISTING CONDITIONS UNKNOWN
ETR EXISTING TO REMAIN
EXP. EXPANSION
E.J. EXPANSION JOINT
EXP'D EXPOSED
EXT'N EXTENSION
EXT EXTERIOR
E.H. EXTRA HEAVY
EXTR. EXTRUDED
F
FAB FABRICATED
F.FIN. FACTORY FINISH
FAS. FASTENER
FT OR' FOOT OR FEET
FPM FEET PER MINUTE
FN FENCE
F.V. FIELD VERIFY
FIG FIGURE
FIN. FINISH/FINISHED
FIN. FLR/ F.F. FINISHED FLOOR
F.A. FIRE ALARM
F (CONTINUED):
F.D. FIRE DAMPER
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
FLASH FLASHING
F.C. FLEXIBLE CONNECTION
FLR FLOOR
F.C.O. FLOOR CLEANOUT
F.D. FLOOR DRAIN
FLR. FIN FLOOR FINISH
FLUOR. FLUORESCENT
FTG FOOTING
FDN FOUNDATION
FR FRAME
FRMG FRAMING
FRZR. FREEZER
FURN. FURNISH
FURR. FURRING
FUT. FUTURE
G
GA. GAUGE
GALV. GALVANIZED
G. GAS
GSKT GASKET
G.V. & B. GATE VALVE AND BOX
G.R. GUARD RAIL
GEN'L GENERAL
GL. GLASS/GLAZING
G.H.T. GLAZED HARD TILE
G.B. GRAB BAR
GRN GRANITE
G.T. GREASE TRAP
GND GROUND
G.F.I. GROUND FAULT INTERRUPTER
GT GROUT
GYP. GYPSUM
GYP. BD. GYPSUM BOARD
H
H.C. HANDICAPPED
H.R. HANDRAIL
HDW HARDWARE
HDWD. HARDWOOD
HD HEAD
HDR. HEADER
HTR HEATER
H/V HEATING AND VENTILATING
H.V.A.C HEATING, VENTILATING & AIR CONDITIONING
HHWR HEATING HOT WATER RETURN
HHWS HEATING HOT WATER SUPPLY
HT HEIGHT
HEX. HEXAGON
H. HIGH
H.I.D. HIGH INTENSITY DISCHARGE
H.P. HIGH POINT
H.PR. HIGH PRESSURE
H.S. HIGH STRENGTH
H.V. HIGH VOLTAGE
HWY HIGHWAY
H.C. HOLLOW CORE
H.M. HOLLOW METAL
HK HOOK
HORIZ. HORIZONAL
HO HORSEPOWER
H.B. HOSE BIB
H.W. HOT WATER
H.W.H. HOT WATER HEATER
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
H (CONTINUED):
HR HOUR
HYD. HYDRANT
I
I.D. INSIDE DIMENSION
INCAND. INCANDESCENT
IN. OR " INCH(ES)
INCL. INCLUDE/INCLUDING
I/W INDIRECT WASTER
INFO INFORMATION
INST'L INSTALL/INSTALLATION
INSUL INSULATE/INSULATION
INT. INTERIOR
INTER. INTERMEDIATE
INV. INVERT
I.E. INVERT ELEVATION
J
J.C. JANITOR CLOSET
JT JOINT
JST JOIST
J.B. JUNCTION BOX
K
K.P. KICKPLATE
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATT
K KIP (1000#)
KIT. KITCHEN
K.D. KNOCKDOWN
K.O.P. KNOCK OUT PANEL
L
LBL. LABEL
LAB. LABORATORY
LAD. LADDER
L.B. LAG BOLT
LAM. LAMINATE/LAMINATED
LDG LANDING
LGE LARGE
LDRY LAUNDRY
LAV. LAVATORY
L.H. LEFT HAND
LGTH OR L LENGTH
LEV LEVEL
LT. LIGT
LTG LIGHTING
L.P. LIGHTING PANEL
LMS LIMESTONE
LTL LINTEL
L.F. LINEAR FOOT/FEET
LIQ. LIQUID
L.L. LIVE LOAD
LOC. LOCATION
LG LONG
L.L.H. LONG LEG HORIZONTAL
L.L.V. LONG LEG VERTICAL
LVR LOUVER
L.O. LOUVER OPENING
L.P. LOW POINT
L.PR. LOW PRESSURE
LBS. OR # POUNDS
M
MACH. MACHINE
M.A.U. MAKE-UP AIR UNIT
M.D.P. MAIN DISTRIBUTION PANEL
M.S.B MAIN SWITCH BOARD
MAINT. MAINTENANCE
M.H. MANHOLE
MFR. MANUFACTURER
MAR. MARBLE
M.O. MASONRY OPENING
MAX. MAXIMUM
MECH. MECHANICAL
NED. MEDIUM
MEMB. MEMBRANE
MET. METAL
M.D.S. METAL DIVIDER STRIP
M.E. METAL EDGE
M.L. METAL LATH
M.L.&PLAS. METAL LATH & PLASTER
M.T. MARBLE THRESHOLD
MEZZ. MEZZANINE
MDOT MICHIGAN DEPARTMENT OF TRANSPORTATION
MIN. MINIMUM
MISC. MISCELLANEOUS
MTD MOUNTED
MTG MEETING
N
NRC NOISE REDUCTION COEFFICIENT
NOM. NOMINAL
N. NORTH
N.I.C NOT IN CONTRACT
N.T.S. NOT TO SCALE
NO. OR # NUMBER
O
OBS OBSCURE
O.C. ON CENTER
OPQ. OPAQUE
OPG. OPENING
OPER. OPERATOR
OPP. OPPOSITE
ORN. ORNAMENTAL
OZ. OUNCE
O.A. OUTSIDE AIR
O.D. OUTSIDE DIAMETER
O.A. OVERALL
OHD OVERHEAD
O.F. OVERFLOW
P
PTD PAINTED
PR PATCH AND REPAIR
PNL PANEL
P.T.D. PAPER TOWEL DISPENSER
PKG PARKING
P.BD. PARTICLE BOARD
PASS. PASSAGE
PVMT PAVEMENT
PED PEDESTAL
PERF. PERFORATED
PLAS. PLASTER
P.LAM. PLASTIC LAMINATE
PL. PLATE
PLBG PLUMBING
PLWD PLYWOOD
PT POINT
POL. POLISH(ED)
PVC POLYVINYLCHLORIDE
P (CONTINUED):
PORC. PORCELAIN
PORC.ENAM. PORCELAIN ENAMEL
POR. POROUS
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PCF POUNDS PER CUBIC FOOT
P.P. POWER PANEL
P/C PRECAST
PREFAB PREFABRICATE
PFN. PREFINISHED
P.T. PRESSURE TREATED
P.G. PRESSURE GAUGE
P.R.V. PRESSURE REDUCING VALVE
PRIM. PRIMARY
PROJ. PROJECT/PROJECTION
PROP. PROPERTY/PROPOSED
P.L. PROPERTY LINE
P.A. PUBLIC ADDRESS
P.S. PURSE SHELF
P.B. PUSH BUTTON
Q
QTY QUANTITY
Q.T. QUARRY TILE
QTR QUARTER
QTR.RD. QUARTER ROUND
R
R. RISER
RAD. OR R. RADIUS
R.C. ROOF CONDUCTOR
R.R. RAILROAD
REF. REFER/REFERENCE
REFL. REFLECT(ED)
REFR. REFRIGERATOR
REINF. REINFORCE(MENT)
REQ'D REQUIRED
R.A. RETURN AIR
REV. REVISED/REVISION
RPM REVOLUTIONS PER MINUTE
R.H. RIGHT HAND
R.O.W. RIGHT OF WAY
RD ROAD
RF ROOF
R.D. ROOF DRAIN
R.S. ROOF SUMP
R.T.U. ROOFTOP UNIT
RM ROOM
R.O. ROUGH OPENING
R.B. RUBBER BASE
S
SAN. SANITARY
S.N.D. SANITARY NAPKIN DISPENSER
S.N.R. SANITARY NAPKIN RECEPTACLE
SCHED. SCHEDULE
STG. SEATING
SEC SECTION
SERV. SERVICE
SHT SHEET
SHWR SHOWER
SIM SIMILAR
S.D. SOAP DISPENSER
S.C. SOLID CORE
STC SOUND TRANSMISSION CLASS
S SOUTH
S (CONTINUED):
S SOUTH
SP SPACE
SPKR SPEAKER
SPEC. SPECIFICATIONS
SQ. SQUARE
S.F. SQUARE FEET
S.S. STAINLESS STEEL
STD STANDARD
STM STEAM
STL STEEL
STOR STORAGE
ST. STREET
STRUCT. STRUCTURAL
SUSP. SUSPEND(ED)
SWBD SWITCHBOARD
SWGR SWITCHGEAR
SYM. SYMBOL
SYS. SYSTEM
T
T.BD TACKBOARD
TECH TECHNICAL
TEL. TELEPHONE
TV TELEVISION
TEMP TEMPORARY
TERR. TERRAZZO
T. THERMOSTAT
THRU THROUGH
T&G TONGUE AND GROOVE
T&B TOP AND BOTTOM
T/C TOP OF CURB
T/F TOP OF FOOTING
T/G TOP OF GUTTER
TRFR TRANSFORMER
T TREAD
T.D. TRENCH DRAIN
TYP. TYPICAL
U
U.C. UNDERCUT
U.G. UNDERGROUND
UL UNDERWRITER'S LABORATORY
UNFIN. UNFINISHED
U.H. UNIT HEATER
U.V. UNIT VENTILATOR
U.N.O. UNLESS NOTED OTHERWISE
UR URINAL
V
VAR VARIABLE
VARN. VARNISH
VNR. VENEER
V. VENT
VTR VENT THRU ROOF
V.I.F. VERIFY IN FIELD
V.M. VERIFY WITH MANUFACTURER
VS VERSUS
VERT. VERTICAL/VERTICALLY
VEST. VESTIBULE
VCT VINYL COMPOSITION TILE
V.R.S. VINYL REDUCER STRIP
VIT. VITREOUS
VOL. VOLUME
V VOLTS
W
WAINS. WAINSCOT
W.C.O WALL CLEANOUT
W.H. WALL HYDRANT
W.V. WALL VENT
W.F. WASH FOUNTAIN
W. WASTE
W.C. WATER CLOSET
W.H. WATER HEATER
WP WATERPROOF
WT. WEIGHT
W.W.F. WELDED WIRE FABRIC
W WEST
W. WIDE/WIDTH
W.B. WALL BASE
W.O. WINDOW OPENING
W.M. WIRE MESH
W/ WITH
W/O WITHOUT
WD WOOD
W.P. WORKING POINT
Y
YD YARD
Y.P. YIELD POINT
Y.S. YIELD STRENGTH
YR YEAR
Z
ZC ZINC
-3
9"
2'-10" MAX TO
SURFACE WHEN
OPEN
-4
3"
ST
AN
DI
NG
PE
RS
ON
S 3'-
0" B
.F
5" MAX 1'-3"
MAX
DRINKING FOUNTAIN
SPOUT LOCATION
8" MIN
2'- 3"
M
IN
9" MIN
11"
MIN
KNEE CLEARANCE
6" MAX
9" MIN
TOE CLEARANCE
© Ehresman Architects
A0.00Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
General Information
Bidding and Permits: 23 April 2026
K:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpgK:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpgK:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpg
K:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpg K:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpg K:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpg
GENERAL NOTES:
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
G2. MANUFACTURER DETAILS ARE INCLUDED AS A GENERAL REFERENCE TO DEMONSTRATE THE INTENT OF THE PROJECT. MANUFACTURER TO CONFIRM DETAILS AND/OR PROVIDE ADDITIONAL OR ALTERNATE
DETAILS AS MAY BE REQUIRED FOR A COMPLETE WARRANTED SYSTEM.
G3. MANUFACTURER DETAILS ARE NOT PROJECT SPECIFIC. COORDINATE WITH ACTUAL FIELD CONDITIONS AND/OR REFER TO ADDITIONAL DETAILS INCLUDED IN THE CONTRACT DOCUMENTS FOR FURTHER
INFORMATION.
G4. ALL DETAILS USED FOR THIS PROJECT SHALL BE MINIMUM 25-YEAR WARRANTED.
GENERAL NOTES:
© Ehresman Architects
A0.50Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Manufacturing Roofing Details
Bidding and Permits: 23 April 2026
No Scale Manufacturer Detail U-5A1
A0.50No Scale Manufacturer Detail U-5D2
A0.50No Scale Manufacturer Detail U-6A3
A0.50
No Scale Manufacturer Detail U-8A4
A0.50No Scale Manufacturer Detail U-8D.15
A0.50No Scale Manufacturer Detail U-1A.16
A0.50
K:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpgK:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpgK:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpg
UP TO 30-YEAR WARRANTY
UP TO 20-YEAR WARRANTY
K:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpg K:\_ 00 Australia (DONT ERASE THIS)\CARLISLE\LOGOS\Carlisle SynTec Systems Logo_Dec 2011-For Print.jpg
GENERAL NOTES:
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
G2. MANUFACTURER DETAILS ARE INCLUDED AS A GENERAL REFERENCE TO DEMONSTRATE THE INTENT OF THE PROJECT. MANUFACTURER TO CONFIRM DETAILS AND/OR PROVIDE ADDITIONAL OR ALTERNATE
DETAILS AS MAY BE REQUIRED FOR A COMPLETE WARRANTED SYSTEM.
G3. MANUFACTURER DETAILS ARE NOT PROJECT SPECIFIC. COORDINATE WITH ACTUAL FIELD CONDITIONS AND/OR REFER TO ADDITIONAL DETAILS INCLUDED IN THE CONTRACT DOCUMENTS FOR FURTHER
INFORMATION.
G4. ALL DETAILS USED FOR THIS PROJECT SHALL BE MINIMUM 25-YEAR WARRANTED.
© Ehresman Architects
A0.51Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Manufacturing Roofing Details
Bidding and Permits: 23 April 2026
No Scale Manufacturer Detail U-1C1
A0.51No Scale Manufacturer Detail U-1D.12
A0.51No Scale Manufacturer Detail U-8C3
A0.51
No Scale Manufacturer Detail U-13E4
A0.51No Scale Manufacturer Detail U-16A.15
A0.51No Scale Manufacturer Detail U-96
A0.51
GENERAL NOTES:
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
G2. MANUFACTURER DETAILS ARE INCLUDED AS A GENERAL REFERENCE TO DEMONSTRATE THE INTENT OF THE PROJECT. MANUFACTURER TO CONFIRM DETAILS AND/OR PROVIDE ADDITIONAL OR ALTERNATE
DETAILS AS MAY BE REQUIRED FOR A COMPLETE WARRANTED SYSTEM.
G3. MANUFACTURER DETAILS ARE NOT PROJECT SPECIFIC. COORDINATE WITH ACTUAL FIELD CONDITIONS AND/OR REFER TO ADDITIONAL DETAILS INCLUDED IN THE CONTRACT DOCUMENTS FOR FURTHER
INFORMATION.
G4. ALL DETAILS USED FOR THIS PROJECT SHALL BE MINIMUM 25-YEAR WARRANTED.
GUTTER WITH FASCIA
© Ehresman Architects
A0.52Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Manufacturing Roofing Details
Bidding and Permits: 23 April 2026
No Scale Manufacturer Detail E1.31
A0.52
PHOTOS INDICATED ON THIS SHEET ARE INCORPORATED TO ASSIST THE CONTRACTOR IN
UNDERSTANDING THE EXISTING CONDITIONS PRESENT AT THE PROJECT SITE AT EXISTING ROOF AREAS TO BE REPLACED. THESE PHOTOS ARE FOR REFERENCE ONLY AND IN NO WAY ARE THESE PHOTOS TO
BE CONSTRUED AS A COMPLETE AND OVERALL ASSESSMENT OF THE WORK TO BE COMPLETED.
G1.
PHOTOS OF THE EXISTING CONDITIONS ONLY REPRESENT THE CONDITIONS THAT WERE ENCOUNTERED DURING THAT PARTICULAR SITE VISIT AND MAY NOT BE THE EXACT CONDITIONS ENCOUNTERED AS
FURTHER WORK MAY HAVE BEEN PERFORMED AFTER SUCH VISIT. ADDITIONALLY, FURTHER
DETERIORATION MAY HAVE OCCURRED SINCE THAT TIME.
G2.
THESE PHOTOS ARE NOT TO BE USED AS A SUBSTITUTE FOR THE CONTRACTOR VISITING THE PROJECT SITE TO BECOME FAMILIAR WITH THE BUILDING AND THE PRESENT CONDITIONS WHICH MAY AFFECT ITS
PROPOSAL.
G3.
© Ehresman Architects
A0.60Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Representative Photographs
Bidding and Permits: 23 April 2026
2026Scale: No Scale Representative Photo - Area B16
A0.60Scale: No Scale Representative Photo - Area B15
A0.60
Scale: No Scale Representative Photo - Area B12
A0.60Scale: No Scale Representative Photo - Area B11
A0.60
Scale: No Scale Representative Photo - Area B8
A0.60Scale: No Scale Representative Photo - Area B7
A0.60
Scale: No Scale Representative Photo - Area B4
A0.60Scale: No Scale Representative Photo - Area A3
A0.60
Scale: No Scale Representative Photo - Area B14
A0.60
Scale: No Scale Representative Photo - Area B10
A0.60
Scale: No Scale Representative Photo - Area A6
A0.60
Scale: No Scale Representative Photo - Area A2
A0.60
Scale: No Scale Representative Photo - Area B13
A0.60
Scale: No Scale Representative Photo - Area B9
A0.60
Scale: No Scale Representative Photo - Area A5
A0.60
Scale: No Scale Representative Photo - Area A1
A0.60
UNDERSTANDING THE EXISTING CONDITIONS PRESENT AT THE PROJECT SITE AT EXISTING ROOF AREAS TO BE REPLACED. THESE PHOTOS ARE FOR REFERENCE ONLY AND IN NO WAY ARE THESE PHOTOS TO
BE CONSTRUED AS A COMPLETE AND OVERALL ASSESSMENT OF THE WORK TO BE COMPLETED.
G1.
PHOTOS OF THE EXISTING CONDITIONS ONLY REPRESENT THE CONDITIONS THAT WERE ENCOUNTERED DURING THAT PARTICULAR SITE VISIT AND MAY NOT BE THE EXACT CONDITIONS ENCOUNTERED AS
FURTHER WORK MAY HAVE BEEN PERFORMED AFTER SUCH VISIT. ADDITIONALLY, FURTHER
DETERIORATION MAY HAVE OCCURRED SINCE THAT TIME.
G2.
THESE PHOTOS ARE NOT TO BE USED AS A SUBSTITUTE FOR THE CONTRACTOR VISITING THE PROJECT SITE TO BECOME FAMILIAR WITH THE BUILDING AND THE PRESENT CONDITIONS WHICH MAY AFFECT ITS
PROPOSAL.
G3.
© Ehresman Architects
A0.61Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Representative Photographs
Bidding and Permits: 23 April 2026
2026Scale: No Scale Representative Photo - Soffit16
A0.61Scale: No Scale Representative Photo - Area C15
A0.61
Scale: No Scale Representative Photo - Area C12
A0.61Scale: No Scale Representative Photo - Area C11
A0.61
Scale: No Scale Representative Photo - Area B8
A0.61Scale: No Scale Representative Photo - Area B7
A0.61
Scale: No Scale Representative Photo - Area B4
A0.61Scale: No Scale Representative Photo - Area B3
A0.61
Scale: No Scale Representative Photo - Area C14
A0.61
Scale: No Scale Representative Photo - Area B10
A0.61
Scale: No Scale Representative Photo - Area B6
A0.61
Scale: No Scale Representative Photo - Area B2
A0.61
Scale: No Scale Representative Photo - Area C13
A0.61
Scale: No Scale Representative Photo - Area B9
A0.61
Scale: No Scale Representative Photo - Area B5
A0.61
Scale: No Scale Representative Photo - Area B1
A0.61
UNDERSTANDING THE EXISTING CONDITIONS PRESENT AT THE PROJECT SITE AT EXISTING ROOF AREAS TO BE REPLACED. THESE PHOTOS ARE FOR REFERENCE ONLY AND IN NO WAY ARE THESE PHOTOS TO
BE CONSTRUED AS A COMPLETE AND OVERALL ASSESSMENT OF THE WORK TO BE COMPLETED.
G1.
PHOTOS OF THE EXISTING CONDITIONS ONLY REPRESENT THE CONDITIONS THAT WERE ENCOUNTERED DURING THAT PARTICULAR SITE VISIT AND MAY NOT BE THE EXACT CONDITIONS ENCOUNTERED AS
FURTHER WORK MAY HAVE BEEN PERFORMED AFTER SUCH VISIT. ADDITIONALLY, FURTHER
DETERIORATION MAY HAVE OCCURRED SINCE THAT TIME.
G2.
THESE PHOTOS ARE NOT TO BE USED AS A SUBSTITUTE FOR THE CONTRACTOR VISITING THE PROJECT SITE TO BECOME FAMILIAR WITH THE BUILDING AND THE PRESENT CONDITIONS WHICH MAY AFFECT ITS
PROPOSAL.
G3.
© Ehresman Architects
A0.62Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Representative Photographs
Bidding and Permits: 23 April 2026
2026Scale: No Scale Representative Photo - Exterior16
A0.62Scale: No Scale Representative Photo - Exterior15
A0.62
Scale: No Scale Representative Photo - Exterior12
A0.62Scale: No Scale Representative Photo - Exterior11
A0.62
Scale: No Scale Representative Photo - Exterior8
A0.62Scale: No Scale Representative Photo - Exterior7
A0.62
Scale: No Scale Representative Photo - Exterior4
A0.62Scale: No Scale Representative Photo - Exterior3
A0.62
Scale: No Scale Representative Photo - Exterior14
A0.62
Scale: No Scale Representative Photo - Exterior10
A0.62
Scale: No Scale Representative Photo - Exterior6
A0.62
Scale: No Scale Representative Photo - Exterior2
A0.62
Scale: No Scale Representative Photo - Exterior13
A0.62
Scale: No Scale Representative Photo - Exterior9
A0.62
Scale: No Scale Representative Photo - Exterior5
A0.62
Scale: No Scale Representative Photo - Exterior1
A0.62
UNDERSTANDING THE EXISTING CONDITIONS PRESENT AT THE PROJECT SITE AT EXISTING ROOF AREAS TO BE REPLACED. THESE PHOTOS ARE FOR REFERENCE ONLY AND IN NO WAY ARE THESE PHOTOS TO
BE CONSTRUED AS A COMPLETE AND OVERALL ASSESSMENT OF THE WORK TO BE COMPLETED.
G1.
PHOTOS OF THE EXISTING CONDITIONS ONLY REPRESENT THE CONDITIONS THAT WERE ENCOUNTERED DURING THAT PARTICULAR SITE VISIT AND MAY NOT BE THE EXACT CONDITIONS ENCOUNTERED AS
FURTHER WORK MAY HAVE BEEN PERFORMED AFTER SUCH VISIT. ADDITIONALLY, FURTHER
DETERIORATION MAY HAVE OCCURRED SINCE THAT TIME.
G2.
THESE PHOTOS ARE NOT TO BE USED AS A SUBSTITUTE FOR THE CONTRACTOR VISITING THE PROJECT SITE TO BECOME FAMILIAR WITH THE BUILDING AND THE PRESENT CONDITIONS WHICH MAY AFFECT ITS
PROPOSAL.
G3.
© Ehresman Architects
A0.62Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Representative Photographs
Bidding and Permits: 23 April 2026
Scale: No Scale Representative Photo - Exterior2
A0.62Scale: No Scale Representative Photo - Exterior1
A0.62
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
G2.
EXISTING PREFINISHED METAL DOWNSPOUT.
REMOVAL NOTES:
R1.
PLUMBING VENT THROUGH ROOF (VISIBLE) - REMOVE PIPE.
EXISTING ITEMS TO REMAIN:
E1.
FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCING ON THE WORK.G3.
PROTECT ALL EXISTING ITEMS TO REMAIN FROM CONSTRUCTION OPERATIONS SO AS TO NOT CAUSE
DAMAGE.
G4.
CONTRACTOR TO COORDINATE TIMING OF REMOVAL WORK THAT AFFECTS OWNERS OPERATIONS SO AS
NOT TO CAUSE DISRUPTION TO NORMAL ACTIVITIES.
G5.
G6.
G7.
FINAL DUMPSTER LOCATION TO BE COORDINATED WITH OWNER REPRESENTATIVE PRIOR TO PLACING.
CONTRACTOR TO PROVIDE PLYWOOD AND 2X UNDER ALL DUMPSTER WHEELS TO PREVENT DAMAGE TO
EXISTING PAVING. CONTRACTOR TO REPAIR ANY PAVING DAMAGED DUE TO CONSTRUCTION
OPERATIONS.
G8.
CONTRACTOR TO COORDINATE BUILDING ACCESS, CONSTRUCTION ACCESS, ETC. WITH THE OWNERS
REPRESENTATIVE PRIOR TO COMMENCING ON THE WORK.
G9. ALL EXISTING ITEMS ARE TO REMAIN UNLESS NOTED OTHERWISE.
G10.
G11.
G12.
G13.
G14.
G15.
G16.
G17.
G18. ALL WORK NOTES MAY NOT APPLY TO THIS SHEET.
ALL AREAS DISTURBED OR DAMAGED BY CONSTRUCTION OPERATIONS SHALL BE PATCHED, REPAIRED
AND FINISHED BACK TO EXISTING CONDITION.
DISPOSE ALL REMOVED ITEMS OFF SITE PER LOCAL BUILDING AND SAFETY ORDINANCES. ANY ITEM
REQUESTED BY THE OWNER TO BE SALVAGED SHALL BE RETURNED TO THEM.
EXISTING CONDITIONS ARE SHOWN FOR REFERENCE ONLY.
FIELD VERIFY ALL DIMENSIONS, ROOF SUMP LOCATIONS, EQUIPMENT CURBS, ETC. PRIOR TO
COMMENCING WITH CONSTRUCTION OPERATIONS.
EXISTING ROOF DECK THICKNESS AND SLOPE IS UNKNOWN. CONTRACTOR TO VERIFY AFTER
THE ROOFING HAS BEEN REMOVED AND REPORT ANY DISCREPANCIES THAT MAY BE
DISCOVERED TO THE ARCHITECT FOR FURTHER DIRECTION.
© Ehresman Architects
A1.50Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Roof Removals Plan
Bidding & Permits: 23 April 2026
Scale: 1/8"=1'-0" Roof Removals Plan1
A1.50
R9
E1
R9
R6
R9
E3
E1
E1
E1
E3
R8
R7 E7
R6
E1
E3
RR1
R9
RR2
E6 E6 E6
RR3 RR3
R3R3
R9 R2
E1
R6
E3
E1
E2
R6R6
R3 R3
E3
RR1
R9
RR1
R1
R5 R4
R10 E4
TYP
BELOW
TYP. FOR 6
TYP
R5 R4
R10 E4
TYP. FOR 2
RR4
TYP. FOR 2
BELOWBELOWBELOW
TYP
TYP. FOR 6
R5 R4
R10 E4
EXISTING ROOF TO REMAIN
(NO WORK)
EXISTING PREFINISHED METAL GUTTER.R2.
EXISTING SKYLIGHT COVER (ANTICIPATED PLYWOOD COVER) - LOCATION BASED ON OLDER AVAILABLE DRAWINGS (CONTRACTOR TO FIELD VERIFY QUANTITY AND LOCATIONS). CONTRACTOR TO REMOVE
CURB IF ABLE FOR FLUSH ROOF SYSTEM BUT LEAVE IN PLACE IF CANNOT.
R3.
EXISTING METAL ROOFING PANELS, RIDGE CAP, ETC.R4.
EXISTING STEEL ROOF STRUCTURE FRAME (SUPPORTING METAL ROOF, SITTING ON EXISTING BUILT- UP ROOF SYSTEM) - SYSTEM INFORMATION BASED ON VISIBLE LOCATIONS WITHIN ENTRY GABLE AREA.
EXACT CONDITIONS ARE UNKNOWN AND TO BE FIELD VERIFIED.
R5.
EXISTING ROOF DRAIN, SUMP, AND PIPING TO BELOW EXISTING ROOF DECK. CONTRACTOR TO CAP ROOF DRAIN PIPE BELOW ROOF PER CODE REQUIREMENTS. LOCATIONS ARE APPROXIMATE BASED ON OLDER
AVAILABLE DRAWINGS.
R6.
EXISTING BOILER FLUE AND CURB - ECU (C.F.V.)R7.
EXISTING MEMBRANE COVERING BETWEEN MENTAL PANEL RIBS.R8.
EXISTING VERTICAL METAL PANEL FASCIA/SIDING.R9.
EXISTING BUILT-UP ROOFING (BUR) SYSTEM - REFER TO EXISTING COMPOSITION NOTES FOR FURTHER
INFORMATION.
R10.
ANTENNA AND TECHNOLOGY EQUIPMENT - (CFV)E2.
WIND DRIVEN TURBINE ROOF VENTILATOR AND PREPARE AS NEEDED TO MAINTAIN NEW ROOF
WARRANTY. LOCATIONS ARE APPROXIMATE BASED ON OLDER AVAILABLE DRAWINGS. CONTRACTOR TO
CONFIRM OPERATION.
E3.
TECTUM ROOF DECK.E4.
WALL BELOW (ALL INCLUSIVE OF DOORS, WINDOWS, LOUVERS, ETC.)E5.
WALL MOUNTED ELECTRICAL EQUIPMENT BELOW.E6.
GUTTER/TROUGH SYSTEME7.
EXISTING LIGHT/SUPPORT BRACKET IN ORDER TO PERFORM ROOFING OPERATIONS.
REMOVE AND REINSTALL THE FOLLOWING:
RR1.
EXISTING ANTENNA - ECU (C.F.V.)RR2.
EXISTING BOILER FLUE AS REQUIRED TO PERFORM ROOFING OPERATIONS AND FOR NEW GUTTER
INSTALLATION. PROVIDE REVISED MOUNTING TO SUPPORT PIPING AS REQUIRED.
RR3.
EXISTING HEAT TAPE/WIRING AS REQUIRED TO PROPERLY FLASH/LINE EXISTING GUTTER/TROUGH
SYSTEM.
RR4.
ROOF AREA "B"
EXISTING ROOFING COMPOSITION (FOR REFERENCE ONLY UNDER METAL)
· BUILT-UP ROOFING SYSTEM
· PERLITE COVER BOARD
· 2" POLYISOCYANURATE INSULATION
· BITUMINOUS BASE SHEET (EST. TO BE MECHANICALLY FASTENED)
· 2" TECTUM ROOF DECK SET IN BULB TEES
ROOF AREA "A"
EXISTING ROOFING COMPOSITION (FOR REFERENCE ONLY UNDER METAL)
· BUILT-UP ROOFING SYSTEM
· PERLITE COVER BOARD
· 2" POLYISOCYANURATE INSULATION
· BITUMINOUS BASE SHEET (EST. TO BE MECHANICALLY FASTENED)
· 2" TECTUM ROOF DECK SET IN BULB TEES
EXISTING ROOF TO REMAIN
(NO WORK)
E5
TYP. BELOW
E5
TYP. BELOW
TYP. BELOW
E5
INTENT IS TO REMOVE EXISTING ROOFING SYSTEMS COMPETE DOWN TO EXISTING ROOF DECK.
INFORMATION ABOUT EXISTING ROOFING COMPOSITION IS FOR REFERENCE ONLY AND SHOULD BE FIELD
VERIFIED BY THE CONTRACTOR.
AT REMOVED MECHANICAL ITEM, CONTRACTOR TO PATCH / REPAIR AND/OR INFILL ROOF DECK AS
NECESSARY PRIOR TO INSTALLATION OF RIGID INSULATION--E.C.U. (C.F.V.).
CONTRACTOR TO PROTECT OWNER'S EXISTING ASPHALT / CONCRETE PAVING AND/OR LAWN AREAS
FROM CONSTRUCTION TRAFFIC. IF DAMAGE SHOULD OCCUR, CONTRACTOR IS RESPONSIBLE TO
COORDINATE AND PAY FOR ALL REPAIRS TO BRING THE ITEM BACK TO THE CONDITION BEFORE CONSTRUCTION COMMENCED. IT SHALL BE THE OWNER'S OPTION TO HAVE THEIR VENDOR MAKE ANY REPAIRS, AND THE CONTRACTOR'S CONTRACT WILL BE REDUCED VIA CHANGE ORDER TO COVER SUCH
REPAIRS.
EXISTING EQUIPMENT, PENETRATIONS, ROOF DRAINS, CURBS, ETC. IDENTIFIED SHALL BE FIELD VERIFIED BY THE CONTRACTOR WHOM WILL BE RESPONSIBLE FOR THE QUANTITIES, CONDITIONS, HEIGHTS, ETC.
EXISTING ROOF MEP ITEMS (HVAC UNIT, EXHAUST FANS, HOODS, VENT PIPES, ETC.) ARE INDICATED FOR GENERAL REFERENCE AND AREN'T NECESSARILY NOTED. CONTRACTOR TO RAISE ANY EXISTING ROOF CURBS, EXTEND PIPES, ETC. AS REQUIRED TO MAINTAIN ROOFING SYSTEM MANUFACTURER WARRANTY.
DUE TO EXISTING ROOF CONSTRUCTION, NOT ALL EXISTING ITEMS ARE VISIBLE AND ARE LOCATED BASED
ON THE EXISTING AVAILABLE DRAWINGS.
A2.50Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Roof Plan
Bidding & Permits: 23 April 2026
Scale: 1/8"=1'-0" Roof Plan1
A2.50
EXISTING LIGHT/SUPPORT BRACKET IN ORDER TO PERFORM ROOFING OPERATIONS.
REMOVE AND REINSTALL THE FOLLOWING:
RR1.
EXISTING ANTENNA - ECU (C.F.V.)RR2.
EXISTING BOILER FLUE AS REQUIRED TO PERFORM ROOFING OPERATIONS AND FOR NEW GUTTER
INSTALLATION. PROVIDE REVISED MOUNTING TO SUPPORT PIPING AS REQUIRED.
RR3.
EXISTING HEAT TAPE/WIRING AS REQUIRED TO PROPERLY FLASH/LINE EXISTING GUTTER/TROUGH
SYSTEM.
RR4.
A9.10
RR1
RR2 RR3 RR3
11 11
RR1
R9
RR1
TYP. FOR 6
TYP
RC2 TYP. FOR 2
TYP. FOR 2TYP. FOR 6
RC2
TYP
TYP
TYP
TYP
BELOW
3 3
HIGH POINTHIGH POINT
TYP
TYP
TYP
5 5 5 5
5 5 5 5
TYP. FOR 3
TYP. FOR 6
TYP. FOR 6
TYP. FOR 6
TYP. FOR 2
RC1
TYP TYP
11 11
EXISTING ROOF TO REMAIN
(NO WORK)
EXISTING ROOF TO REMAIN
(NO WORK)
ROOFING COMPOSITION NOTES:
ROOFING SYSTEM COMPOSITION (TECTUM ROOF DECK, FLAT):
· 60-MIL FULLY ADHERED EPDM ROOFING MEMBRANE (WITH 25-YEAR DETAILS) CARRIED UP AND OVER
PARAPET WALL
· ADHESIVE APPLIED TAPER INSULATION WITH 1/2" TAPER START (1/4" INCH PER FOOT; AVERAGE
R-VALUE = 17.8)
· MECHANICALLY FASTENED POLYISOCYANURATE INSULATION (2.2 INCHES; R-VALUE = 12.6) WITH
GLASS-FILLED NYLON AUGER FASTENER AND FASTENER PLATE TO SUIT CONDITIONS
· EXISTING TECTUM ROOF DECK SET IN BULB TEES (ASSUMED FLAT)
RC1.
1 4"
PE
R
FO
OT
TA
PE
R
IN
SU
LA
TI
ON
1 4"
PE
R
FO
OT
TA
PE
R
IN
SU
LA
TI
ON
1 4"
PE
R
FO
OT
TA
PE
R
IN
SU
LA
TI
ON
1 4"
PE
R
FO
OT
TA
PE
R
IN
SU
LA
TI
ON
1 4"
PE
R
FO
OT
TA
PE
R
IN
SU
LA
TI
ON
1 4"
PE
R
FO
OT
TA
PE
R
IN
SU
LA
TI
ON
TYP
RE
FE
R
TO
N
OT
E #1
2 A
ND
#R R4
IN
T
HI
S
AR
EA
ROOF AREA "B"
ROOF AREA "A"
GENERAL NOTES:
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
G2.
G3.
G4.
G5.
G6.
G7.
G8.
G9.
G10.
G11.
G12.
G13.
G14.
G15.
G16.
G17.
G18.
G19.
G20.
G21.
G22.
REFER TO MANUFACTURER SPECIFICATIONS, REQUIREMENTS, ETC. FOR PROPER ROOFING INSTALLATION PER ARCHITECTURAL SPECIFICATIONS AND WARRANTY CONDITIONS. ROOFING MATERIAL SHALL BE
INSTALLED TO MAINTAIN WARRANTY OF EXISTING ROOFING, IF APPLICABLE.
ALL CURBS, FLASHINGS, ETC. SHALL BE FURNISHED AND INSTALLED TO BE COMPATIBLE WITH THE
ROOFING SYSTEM AND AT HEIGHT REQUIRED TO MAINTAIN ROOFING WARRANTY.
EXISTING CONDITIONS ARE SHOWN FOR REFERENCE ONLY.
ROOF INSULATION TO BE INSTALLED IN MINIMUM 2 LAYERS -- REFER TO SPECIFICATIONS.
ROOFING IN ALL LOCATIONS TO CARRY UP FACE OF PARAPET WALL AND OVER THE TOP--REFER TO
SECTIONS FOR FURTHER DETAIL.
ALL EXISTING ITEMS ARE TO REMAIN UNLESS NOTED OTHERWISE.
ALL WORK NOTES MAY NOT APPLY TO THIS SHEET.
FIELD VERIFY ALL DIMENSIONS, ROOF SUMP LOCATIONS, EQUIPMENT CURBS, ETC. PRIOR TO
COMMENCING WITH CONSTRUCTION OPERATIONS.
THE ROOFING SHALL BE A TWENTY-FIVE (25) YEAR MANUF. ROOFING SYSTEM WARRANTY ALONG WITH A
FIVE (5) YEAR LABOR WARRANTY. EDGE METAL TO BE INCLUDED IN FULL SYSTEM WARRANTY.
REFER TO ROOF DETAILS AND MANUFACTURER'S STANDARD DETAILS FOR ADDITIONAL INFORMATION.
EXISTING ROOF DECK THICKNESS AND SLOPE IS UNKNOWN. CONTRACTOR TO VERIFY AFTER THE ROOFING HAS BEEN REMOVED AND REPORT ANY DISCREPANCIES THAT MAY BE DISCOVERED TO THE
ARCHITECT FOR FURTHER DIRECTION.
ALL EXISTING MECHANICAL EQUIPMENT CURBS SHALL HAVE NEW BASE FLASHING A MINIMUM OF 8" ABOVE THE ROOFING MEMBRANE, UNLESS MORE STRINGENT REQUIREMENTS ARE NEEDED TO MEET THE ROOFING MANUFACTURER SPECIFICATIONS. CONTRACTOR TO FIELD VERIFY HEIGHT--ASSUME THE
EXISTING HVAC CURBS WILL NEED TO BE RAISED.
INSTALL CRICKETS / SADDLES AT ALL EQUIPMENT / SKYLIGHT CURBS HIGH SIDE, WHETHER SHOWN OR
NOT.
EXISTING EQUIPMENT, PENETRATIONS, ROOF DRAINS, CURBS, ETC. IDENTIFIED SHALL BE FIELD VERIFIED BY THE CONTRACTOR WHOM WILL BE RESPONSIBLE FOR THE QUANTITIES, CONDITIONS, HEIGHTS, ETC.
ANY EXISTING WOOD BLOCKING FOR ELECTRICAL CONDUIT AND/OR GAS PIPING SHALL BE REPLACED
WITH PROPER PREFABRICATED SUPPORT WHETHER PARTICULARLY INDICATED OR NOT (NO WOOD
BLOCKING IS PERMITTED).
CONTRACTOR TO VISIT THE SITE AND VERIFY ALL MEASUREMENTS, CONDITIONS, ETC. THAT MAY AFFECT
THE SPECIFIED WARRANTY.
AN ON-SITE PRE-CONSTRUCTION MEETING WITH THE ARCHITECT, ROOFING SYSTEM REPRESENTATIVE, OWNER, AND CONTRACTOR SHALL BE CONDUCTED PRIOR TO THE START OF CONSTRUCTION AND PRIOR
TO ORDERING OF MATERIAL. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION.
ROOFTOP DUCTWORK, GAS LINES, ELECTRICAL CONDUITS, ETC. MAY NOT BE INDICATED FOR DRAWING CLARITY, BUT WILL LIKELY REQUIRE RE-WORK AND MODIFICATIONS DUE TO THE WORK. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS AND COORDINATE WITH OWNER. PROVIDE PROPER SUPPORTS
(ROLLER SUPPORTS, UNISTRUT PADS, ETC.).
REPLACEMENT OF THE ROOF SHALL BE DONE SO-AS TO NOT REMOVE ANY MORE OF THE ROOFING THAN CAN BE REPLACED IN A GIVEN DAY. AT NO TIME SHALL THE ROOF BE LEFT OPEN AND SUBJECT TO
WEATHER CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT OCCURS.
ANY UTILITY SHUT-DOWNS THAT ARE REQUIRED IN ORDER TO PERFORM THE RE-ROOFING OPERATIONS
SHALL BE SCHEDULED IN ADVANCE WITH THE OWNER.
PROVIDE WALKWAY PADS / SLIP SHEETS UNDER ALL PIPE SUPPORTS.
CONTRACTOR TO PROVIDE SLIP FLASHING AT ALL UNITS AND AS REQUIRED.
G28.
PLUMBING VENT / PIPE BOOT FLASHING. CONTRACTOR TO EXTEND PIPE AS MAY BE REQUIRED TO TO MEET MANUFACTURER WARRANTY REQUIREMENTS (SOME PIPES MAY NEED TO BE SHORTENED DUE TO
SLOPED METAL ROOFING REMOVAL).
DRAWING NOTES:
1.
WRAP ROOFING MEMBRANE UP BACK SIDE OF WALL AND UNDER CAP FLASHING.2.
PRE-FINISHED METAL CAP FLASHING (PRE-SLOPED).3.
PREFINISHED METAL GUTTER--SLOPE TO DOWNSPOUT LOCATIONS.4.
PREFINISHED METAL DOWNSPOUT--ELBOW BACK TO BUILDING WALL AND PROVIDE DOWNSPOUT
EXTENSIONS AS REQUIRED TO DIRECT WATER AWAY FROM THE BUILDING AND BIKE RACK CONCRETE
PAD.
5.
G23. CONTRACTOR WILL BE REQUIRED TO BUILD UP THE ROOF EDGE (PARAPET) DUE TO INSULATION HEIGHT.
CONTRACTOR TO FIELD VERIFY AND PROVIDE THE NECESSARY BLOCKING. INTENT IS FOR THE ROOF
EDGE TO BE A CONSISTENT HEIGHT THROUGHOUT A GIVEN ROOF AREA.
G24. DRAINAGE SADDLES TO SLOPE 12" PER FOOT UNLESS NOTED OTHERWISE. CONTRACTOR TO ASSURE
POSITIVE DRAINAGE TO ROOF EDGE.
G25. CONTRACTOR TO PROTECT OWNER'S EXISTING ASPHALT / CONCRETE PAVING AND/OR LAWN AREAS
FROM CONSTRUCTION TRAFFIC. IF DAMAGE SHOULD OCCUR, CONTRACTOR IS RESPONSIBLE TO
COORDINATE AND PAY FOR ALL REPAIRS TO BRING THE ITEM BACK TO THE CONDITION BEFORE CONSTRUCTION COMMENCED. IT SHALL BE THE OWNER'S OPTION TO HAVE THEIR VENDOR MAKE ANY REPAIRS, AND THE CONTRACTOR'S CONTRACT WILL BE REDUCED VIA CHANGE ORDER TO COVER SUCH
REPAIRS.
G26. ROOF INSULATION THICKNESS TO COMPLY WITH THE 2021 MICHIGAN ENERGY CODE REQUIREMENTS FOR
R-30 (AVERAGE R-VALUE).
G27. CONTRACTOR IS RESPONSIBLE FOR ALL MECHANICAL AND ELECTRICAL COSTS ASSOCIATED WITH
RAISING EXISTING EQUIPMENT IF NEEDED TO MEET SYSTEM WARRANTY REQUIREMENTS.
PROVIDE PITCH POCKET / POURABLE SEALANT AT ANTENNAE SUPPORT STRUCTURE.6.
FLASHING AT WIND DRIVEN TURBINE ROOF VENTILATOR PER MANUFACTURER REQUIREMENTS--E.C.U.
(C.F.V.). EQUIPMENT NOT VISIBLE AND LOCATED PER EXISTING AVAILABLE DRAWINGS.
7.
INFILL DECK OPENING AT REMOVED EXISTING ROOF DRAIN (AFTER CAPPING PER CODE REQUIREMENTS).8.
CRICKET AS REQUIRED TO PROVIDE DRAINAGE AROUND EXISTING SKYLIGHT (CONTRACTOR TO ASSUME EXISTING SKYLIGHT CURB CANNOT BE REMOVED)--E.C.U. (C.F.V.). EQUIPMENT NOT VISIBLE AND LOCATED
PER EXISTING AVAILABLE DRAWINGS.
9.
INFILL EXISTING SKYLIGHT WITH 6" COLD-FORMED FRAMING AT 12" O.C., 34" PRESERVATIVE TREATED PLYWOOD, AND MINIMUM 5.2 INCHES POLYISOCYANURATE INSULATION (TWO LAYERS) ON TOP PRIOR TO ROOFING MEMBRANE--E.C.U. (C.F.V.). CONTRACTOR TO ANTICIPATE THAT THEY EXISTING SKYLIGHT CURB
CANNOT BE REMOVED..
10.
PREFINISHED METAL SIDING TO MATCH EXISTING--REFER TO DETAILS AND SPECIFICATIONS.11.
INSTALL MEMBRANE IN EXISTING DRAINAGE TROUGH, UP WALL, AND OVER TOP--TERMINATE AT EXISTING
METAL ROOFING PER MANUFACTURER REQUIREMENTS.
12.
INSULATION SADDLE AT VERTICAL WALL SURFACE TO DIRECT WATER TO GUTTERS.13.
INFILL DECK OPENING AT REMOVED BOILER FLUE PIPE.14.
TYP. BELOW
TYP. BELOW
TYP. BELOW
LINE OF BUILDING WALL.15.
ROOFING SYSTEM COMPOSITION (TECTUM ROOF DECK, FLAT):
· 60-MIL FULLY ADHERED EPDM ROOFING MEMBRANE (WITH 25-YEAR DETAILS) CARRIED UP AND OVER
PARAPET WALL
· ADHESIVE APPLIED TAPER INSULATION WITH 1/2" TAPER START (1/4" INCH PER FOOT; AVERAGE
R-VALUE = 28.5)
· MECHANICALLY FASTENED POLYISOCYANURATE INSULATION (1.5 INCHES; R-VALUE = 8.6) WITH
GLASS-FILLED NYLON AUGER FASTENER AND FASTENER PLATE TO SUIT CONDITIONS
· EXISTING TECTUM ROOF DECK SET IN BULB TEES (ASSUMED FLAT)
RC2.
STRUCTURAL BRACE--REFER TO DETAILS FOR FURTHER INFORMATION.16.
TYP. FOR 3
9'-0" (TYP)
A9.10
A9.10
A9.10
A9.10
A9.10
A9.10
A9.10
TYP. FOR 3
A9.10Project No. 0826
Nottawa Community School District Nottawa Community School (26438 M-86) Roof Replacement
Sections & Details
Bidding & Permits: 23 April 2026
Scale: 1-1/2"=1'-0" Section at Gabled Entry1
A9.10
GENERAL NOTES:
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
REFER TO MANUFACTURER SPECIFICATIONS, REQUIREMENTS, ETC. FOR PROPER ROOFING INSTALLATION
PER ARCHITECTURAL SPECIFICATIONS AND WARRANTY CONDITIONS.
Scale: 1-1/2"=1'-0" Section at Roof Area "B" Overhang Edge2
A9.10Scale: 1-1/2"=1'-0" Section at Roof Area "A" Edge3
A9.10
Scale: 1-1/2"=1'-0" Section at Roof Area "A" Overhang Edge4
A9.10
Scale: 1-1/2"=1'-0" Section at Roof Area "B" Edge5
A9.10
Scale: 1-1/2"=1'-0" Section at Existing Drainage Trough6
A9.10
Scale: 1-1/2"=1'-0" Brace Rail Connection Plan7
A9.10
Scale: 1-1/2"=1'-0" Center Brace Plate Detail9
A9.10
Scale: 1-1/2"=1'-0" Side Brace Plate Detail10
A9.10
Scale: 1-1/2"=1'-0" Brace Rail Connection Plan8
A9.10
A9.10
A9.10
A9.10
A9.10
CENTER
SIDES
4 4
TYP
TYP
9 8
REFER TO NOTE #24
BEYOND
RE
FE
R
TO
N
OT
E #2
1'-6"
6" 41 2" 6"
4"
9 8
1 1 2 " 2014
11 2"
2"
1'-6" 3 4"
6" 41 2" 6"
4"
1'-6"
1'- 0"
TYP
1'-6"
2'- 4"
TYP
8" O
.C
TY
P)
4"
2 6 2 6
2 62 8
2 6
2 6 2 6
2 6
2 8 2 6
2 6
2 6 2 4
L.P. ROOFING
H.P. ROOFING
TOP OF WALL
53 4" M
IN
(V
.M
EXISTING TECTUM ROOF DECK2"
75 8"
L.P. ROOFING
H.P. ROOFING
TOP OF WALL
53 4" M
IN
(V
.M
EXISTING TECTUM ROOF DECK2"
1 2"
202323 31
2323 31
L.P. ROOFING
H.P. ROOFING
TOP OF WALL
53 4" M
IN
(V
.M
EXISTING TECTUM ROOF DECK2"
1 2"
32REFER TO NOTE #19
E.C.U. (C.F.V.)
TOP OF WALL
EXISTING TECTUM ROOF DECK
6'-
31 4" (
MA
TC
H
EX
IS
TI
NG
G
AB
LE
H
EI
GH
T
AT
H
IG
H
PO
IN
T-
-C .F
.V
(R
EF
ER
T
O
NO
TE
#3
5 E
NT
IR
E
W
AL
L)
G2.
DRAWING NOTES:
METAL STUD TOP / BOTTOM TRACK (600T125-33)--SECURE WITH TWO (2) #10 EACH STUD.1.
STUD BRACING (600S137-43) WITH TWO (2) #10 AT EACH STUD.2.
4" x 3" GALVANIZED STEEL PLATE WITH TWO (2) 38" DIAMETER BOLTS THROUGH DOUBLE-STUDS WITH
WASHERS.
3.
METAL STUD WALL FRAMING (600S137-43) @ 24" O.C.4.
16-GAUGE CONTINUOUS PLATE.5.
TWO (2) ROWS SIMPSON SDS22 SCREWS @ 24" O.C., 11
2" PENETRATION TO 2x.6.
CONTINUOUS 2 x 6 PRESERVATIVE TREATED BLOCKING.7.
SLOT PIPE AT KNIFE PLATE AND ATTACH WITH 12" DIAMETER BOLT (TYP).8.
1 12" DIAMETER SCHEDULE 40 GALVANIZED PIPE @ 9'-0" O.C.9.
DOUBLE METAL STUD (AT PLATE).10.
2" DIAMETER BOLT.11.
#10 @ 12" O.C. TO PLATE (TYP).12.
2" x 1'-6" GALVANIZED STEEL PLATE--REFER TO LOCATION FOR SIZE.13.
8" x 6" x 10" GALVANIZED STEEL PLATE WELDED TO BASE PLATE (VERIFY EXACT HEIGHT PRIOR TO
FABRICATION WITH ROOF SYSTEM THICKNESS).
14.
SHIM TOP OF WALL / VOID SOLID.15.
2" DIAMETER THREADED ROD EPOXY SET WITH HILTI HY-270 (MINIMUM 6" EMBEDMENT) INTO EXISTING
BOND BEAM. CONTRACTOR TO FIELD VERIFY BOND BEAM PRESENCE AND CONDITIONS.
16.
EXISTING CMU / MASONRY WALL--E.C.U. (C.F.V.).17.
EXISTING BOND BEAM--VERIFY PRESENCE AND CONDITION IN THE FIELD. REPORT ANY DISCREPANCIES
TO THE ARCHITECT FOR DIRECTION.
18.
EXISTING DRAINAGE TROUGH WITH HEAT TAPE--REMOVE AND REINSTALL HEAT TAPE IN ORDER TO
PROPERLY TIE-IN PER MANUFACTURER REQUIREMENTS.
19.
ROOFING SYSTEM (MEMBRANE & INSULATION)--REFER TO SHEET A2.50 FOR FURTHER INFORMATION.20.
EXISTING TECTUM ROOF DECK--E.C.U. (C.F.V.).21.
CARRY ROOFING MEMBRANE UP FACE OF WALL AND OVER TOP OF WALL.22.
4" PRESERVATIVE TREATED PLYWOOD SHEATHING.23.
EXISTING SOFFIT MATERIAL TO REMAIN--E.C.U. (C.F.V.). CONTRACTOR TO REMOVE AND REINSTALL SOFFIT
AS REQUIRED FOR MEANS AND METHODS OF CONSTRUCTION.
24.
EXISTING FRIEZE BOARD--E.C.U. (C.F.V.).25.
MANUFACTURER'S 25-YEAR GUTTER TIE-IN DETAIL.26.
2x PRESERVATIVE TREATED WOOD BLOCKING.27.
PREFINISHED METAL GUTTER--SLOPE TO DOWNSPOUT LOCATIONS.28.
GUTTER BRACKET AND FASTENER @ 32" O.C. MAXIMUM.29.
GUTTER STRAP SPACER.30.
2x PRESERVATIVE TREATED WOOD BLOCKING / WALL.31.
EXISTING SLOPED METAL ROOF TO REMAIN--CONTRACTOR TO TIE IN PER MANUFACTURER'S
REQUIREMENTS.
32.
ALL PREFINISHED METAL COPING, EDGE METAL, ETC. TO BE COMPLETE WITH CONCEALED CLIP ANCHORS
ON BOTH SIDES (NO VISIBLE ANCHORS).
G3.
CARRY ROOFING UP AND OVER ALL WALLS, PARAPET EDGES, ETC.G4.
TYP
2 8 2 6
PREFINISHED METAL SIDING COMPLETE WITH ALL ACCESSORIES, CLOSURES, CLIPS, OUTSIDE CORNERS, ETC. FOR A COMPLETE INSTALLATION (SIMILAR TO ATAS INTERNATIONAL; DESIGN WALL: DWH120 WITH 6"
UP, 6" DOWN).
33.
PREFINISHED METAL SIDING CLOSURE / DRIP AT TOP AND BOTTOM OF WALL TO SUIT CONDITIONS.34.
SELF-ADHERING WEATHER RESISTIVE BARRIER AT FACE OF PLYWOOD SHEATHING (UNDER SIDING).35.
PREFINISHED METAL CAP WITH PRE-SLOPED CONTINUOUS CLEAT.36.
Scale: 3"=1'-0" Gutter Detail11
A9.10
A9.10
A9.10
SIMILAR2 4
REINFORCED EPDM MEMBRANE.37.
6" PRESSURE SENSITIVE TAPE.38.
EPDM ROOFING MEMBRANE.39.
SHEET METAL FASCIA AND CONTINUOUS CLEAT.40.
CLEAT FASTENER--INSTALL TYPE AND SPACING PER MANUFACTURER REQUIREMENTS.41.
42. FLANGE FASTENER--INSTALL TYPE AND SPACING PER MANUFACTURER REQUIREMENTS.
| TTL |
| Sheets and Views |
| TTL |
| A0.00 |
| Sheets and Views |
| A0.00 |
| A0.50 |
| Sheets and Views |
| A0.50 |
| A0.51 |
| Sheets and Views |
| A0.51 |
| A0.52 |
| Sheets and Views |
| A0.52 |
| A0.60 |
| Sheets and Views |
| A0.60 |
| A0.61 |
| Sheets and Views |
| A0.61 |
| A0.62 |
| Sheets and Views |
| A0.62 |
| A0.63 |
| Sheets and Views |
| A0.63 |
| A1.50 |
| Sheets and Views |
| A1.50 |
| A2.50 |
| Sheets and Views |
| A2.50 |
| A9.10 |
| Sheets and Views |
| A9.10 |
File details come from the government source that posted it. Updated .