2026_03.25 Niantic Drawings.pdf
PDF 4 MB Posted
- Solicitation number
- WS-001-2026
- Issued by
- New London County, North Granby CDP, Connecticut
About this file
This is a set of architectural drawings and design specifications for the Town of East Lyme, Connecticut, detailing roof replacement work at two municipal pump stations: the Niantic Pump House located at 141 Main Street, Niantic, CT 06357, and the Pattagansett Pump House located at 32A West Main Street, Niantic, CT 06062. The project involves complete roof system replacement at both facilities, including removal of existing synthetic slate shingles, lead-coated copper flashing, and felt underlayment down to the structural deck. New construction includes a multi-layer roofing system comprising asphalt shingles over self-adhering sheet underlayment, rigid insulation boards, vapor barriers, and prefabricated vented nailable insulation panels. The project scope also encompasses installation of new 5-inch metal gutters and downspouts, replacement of fascia boards, step flashing at wall penetrations, and reinstallation of existing equipment including antennas and exhaust vents. Both buildings are Group U structures originally constructed in 1987 (Niantic) and 1988 (Pattagansett), and the work was issued for bid on March 25, 2026, with drawings prepared by Friar Architecture of Farmington, Connecticut, and structural engineering by GR Engineering LLC of Thomaston, Connecticut.
The roofing system design achieves insulation values of R-33.39 continuous insulation at the Niantic location and R-30 continuous insulation minimum per the 2021 International Energy Conservation Code for Climate Zone 5A, with specific roof venting panel fastener specifications and maximum uplift requirements of 450 pounds per clip. All work must be performed in strict accordance with applicable codes including the 2021 International Building Code, Mechanical Code, Plumbing Code, Energy Conservation Code, Fire Code, Life Safety Code, and the 2020 National Electrical Code, all as amended by Connecticut. The contractor bears responsibility for coordinating demolition efforts including asbestos abatement work, verifying field dimensions before material ordering, correcting any discrepancies between contract drawings and actual field conditions, and ensuring proper integration of new work with existing construction to maintain continuous surfaces throughout both facilities.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INDEX OF DRAWINGS
SITE LOCATION MAP
RE
BMUN
TE
S
NIANTIC AND PATTAGANSETT PUMP
STATIONS ROOF REPLACEMENT
NIANTIC
141 MAIN ST,
NIANTIC, CT 06357
PATTAGANSETT
32A WEST MAIN STREET,
NIANTIC, CT 06062
STRUCTURAL ENGINEER
GR ENGINEERING LLC
135 EAST MAIN STREET
THOMASTON, CONNECTICUT 06787
ISSUE FOR BID
03/25/2026
ARCHITECT
FRIAR ARCHITECTURE
21 TALCOTT NOTCH ROAD
FARMINGTON, CONNECTICUT
REFERENCE
R1.1 REFERENCE SHEET
STRUCTURE
S1.1 ROOF FRAME OVERLAY PLAN NIANTIC
S1.2 ROOF FRAME OVERLAY PLAN PATTAGANSETT
ARCHITECTURE
A2.1 ROOF PLANS - NIANTIC
A2.2 ROOF PLANS - PATTAGANSETT
A2.3 TYPICAL DETAILS
A2.4 NIANTIC AND PATTAGANSETT ROOF DETAILS
FIRST SELECTMAN
DAN CUNNINGHAM
PUBLIC WORKS DIRECTOR
JOSEPH J. BRAGAW, PE
CHIEF OPERATING OFFICER, WATER & SEWER
BEN NORTH PATTEGANSETT
PUMP STATION
NIANTIC PUMP
STATION
METAL (SMALL)
METAL LATH
MARBLE
GYSUM BOARD
GRAVEL
GLAZING
GLAZED BRICK
GLASS BLOCK
FIRE BRICK
FINISHED WOOD
FACE GRAIN
FACE BRICK
TERRAZZO
TERRA-COTTA
STRUCT. GLAZED
FACING TILEEARTH
CONCRETE
C.M.U.
STRUCTURAL CLAY
STEEL
SLATE, FLAGGING,
SOAPSTONE
CERAMIC TILE
CAST STONE
CARPET
SHEATHING INSUL.
RUBBLE
ROUGH WOOD
(INTERUPTED)
BRASS OR BRONZE
BITUMINOUS
BATT INSULATION
ROUGH WOOD
(CONTINUUS)
RIGID INSULATION
PLYWOOD ( SMALL)
ACOUSTICAL TILE PLASTER
ALUMINUM
ARCHITECTURAL MATERIALS
CELLULAR PVC
FLAT METAL PANEL
SLATE, FLAGGING,
SOAPSTONE
METAL PANEL
CORRUGATED
GLASS
CERAMIC TILE
CONCRETE BLOCK
BRICK
ELEVATIONS
BUILDING SECTION
ARCHITECTURAL SYMBOLS
WALL SECTION
COLUMN CENTERLINE
DETAIL DESIGNATION, PLAN DETAIL,
LARGE SCALE PLANS
INTERIOR ELEVATIONS
CASEWORK ELEVATIONS
CEILING DESIGNATION
ROOM NUMBER
DOOR NUMBER
WINDOW DESIGNATION
DEMOLATION TAG
WALL TYPES
PHOTO LOCATION
REVISION NUMBER
DATUM / ELEVATION / LEVEL LINE
EXISITING CONSTRUCTION TO REMAIN
NEW STUD CONSTRUCTION
NEW CONCRETE BLOCK
NEW FACE BRICK
SOFFITS / OVERHANG ABOVE
THIS REPRESENTS A 30"X48" ADA
WHEELCHAIR CLEARANCE. IN ADDITIONIT
REPRESENTS A 30" CLEAR WIDTH.
ACCESSIBLE ELEMENT
AREA OF REFUGE WHEELCHAIR SPACE ACCESS.
CLEAR FLOOR SPACE ASSEMBLY WHEELCHAIR
SEAT 30"x48" CLEAR FLOOR SPACE
CORNER GUARD
SECTION NUMBER
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
LETTERS (HORIZ.)
SHEET NUMBER
NUMBERS (VERT.)
DETAIL NUMBER
SHEET NUMBER
ELEVATION NUMBER
ELEVATION NUMBER
CEILING TYPE (LETTER)
CEILING HEIGHT (NUMBER)
NUMBER
NUMBER/TYPE
LETTER/TYPE
NUMBER
NUMBER
PHOTO NUMBER
NUMBER
MIN.
30" CLR
M
IN
C
LR
CONSTRUCTION NOTES
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL CODES AND
ORDINANCES.
DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION OF
DIMENSIONS FROM THE ARCHITECT BEFORE CONTINUING WITH CONSTRUCTION.
CONTRACT DRAWINGS MAY VARY FROM ACTUAL FIELD CONDITIONS. CONTRACTOR SHALL CORRECT DIMENSIONS
OF ALL MATERIALS TO CARRY OUT OF THE INTENT OF THE CONTRACT DRAWINGS. VERIFY ALL DIMENSIONS AND
EXISTING CONDITIONS IN FIELD BEFORE ORDERING ANY MATERIALS. CONTRACTOR SHALL NOTIFY ARCHITECT
PROMPTLY OF ANY CRITICAL DISCREPANCIES BEFORE PROCEEDING WITH WORK.
ALL NEW WORK SHALL BE IMPLEMENTED SO AS TO PROVIDE A SMOOTH AND CONTINUOUS SURFACE WITH ALL
EXISTING CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK NECESSARY TO ACHIEVE THIS
REQUIREMENT, EVEN THROUGH PROCEDURES ARE NOT DETAILED FOR EACH SPECIFIC CONDITION OR
COMBINATION OF CONDITIONS. QUALITY OF WORKMANSHIP, MATERIALS AND FINISHES SHALL BE EQUAL TO THE
LEVEL ESTABLISHED FOR SIMILAR CONSTRUCTION, EXCEPT WHERE EXISTING APPEARANCE IS TO BE MATCHED TO
ACHIEVE CONTINUITY.
CUTTING AND PATCHING SHALL BE THE RESPONSIBILITY OF THE TRADE WHOSE WORK RESULTS IN THE NEED FOR
CUTTING AND PATCHING UNLESS A SPECIFIC CONTRACTOR IS CALLED OUT ON THE DRAWINGS. ALL HOLES LEFT BY
REMOVING MECHANICAL, PLUMBING AND ELECTRICAL EQUIPMENT, ETC. SHALL BE PATCHED.
CONTRACTOR SHALL PROVIDE WOOD BLOCKING AT WALLS AS REQUIRED.
1.
2.
3.
4.
5.
6.
GENERAL NOTES
1.) DIMENSION CRITERIA
A. FROM FACE TO METAL STUD TO FACE OF METAL STUD
B. FROM FACE TO METAL STUD TO FACE OF CONCRETE MASONRY UNIT
C. FROM FACE TO CONCRETE MASONRY UNIT TO FACE OF CONCRETE MASONRY UNIT
ABBREVIATIONS
ABOVE FINISH FLOOR
ABOVE FINISH GRADE
ACOUSTIC TILE
AIR CONDITIONING
AIR HANDLING UNIT
ALTERNATE
ALUMINUM
ANCHOR, ANCHORAGE
ANCHOR BOLTS
ANGLE
ANODIZED
APPROVED
ARCHITECTURAL / ARCHITECT
ASBESTOS
ASPHALT
ASSEMBLY
ASSISTANT
AT
AUTOMATIC
BEAM
BEARING
BETWEEN
BEVEL / BEVELED
BITUMINOUS
BLOCK
BLOCKING
BOARD
BOTTOM OF
BOTTOM
BUILDING
BUILT-UP ROOF
CABINET UNIT HEATER
CAPACITY
CEILING
CEILING HEIGHT
CEMENT
CENTER
CENTERLINE
CERAMIC
CHALKBOARD
CHANNEL
CLOSET
COLUMN
CONFERENCE
CONTROL OR
CONSTRUCTION JOINT
CONTINUOUS
CONTRACTOR
CORRIDOR
COURSE / COURSES
DAMPPROOFING
DEGREE
DEMOLITION
DEPARTMENT
DETAIL
DIAMETER
DIMENSION
DISTANCE
DOOR
DOUBLE
DOUBLE HUNG
DOWN
DOWNSPOUT
DRAWING
DRINKING FOUNTAIN
EACH
ELECTRIC / ELECTRICAL ELECTRICAL
WATER COOLER
ELEVATION
ELEVATOR
EXISTING FIRE EXTINGUISHER
EMERGENCY
EQUAL
EQUIPMENT
EXISTING
EXISTING TO REMAIN
EXPANSION JOINT
EXTERIOR INSULATION
FINISH SYSTEM
FEET, FOOT
FINISH, FINISHED
FIRE DAMPER
FIRE EXTINGUISHER/FIRE BLANKET
CABINET
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER & BRACKET
FIRE RETARDANT
FIREPROOFING
FIXTURE
FLASHING
FLOOR DRAIN
FLOOR FINISH
FOOTING
FOUNDATION
FUME HOOD
FURNISH / FURNISHED
FURRED / FURRING
INCH OR INCHES
INCLUDE / INCLUDING
INFORMATION
INSIDE DIAMETER
INSULATION
INTERIOR
JOINT
KICK PLATE
LABORATORY
LAVATORY
LIGHTING
MACHINE
MAINTENANCE
MANUFACTURER
MARKER BOARD
MASONRY
MASONRY OPENING
MATERIAL
MAXIMUM
MECHANICAL
METAL
MEZZANINE
MINIMUM
MISCELLANEOUS
OFFICE
ON CENTER
OPPOSITE HAND
OPENING
OUTSIDE DIAMETER
PAINTED
PAIR
PAPER TOWEL DISPENSER
PERPENDICULAR
PLASTER
PLASTIC LAMINATE
PLATE
PLUMBING
PLYWOOD
PRECAST
PREFABRICATED
PRESSURE TREATED
PROJECT, PROJECTION POINT
QUANTITY
QUARRY TILE
RADIUS
RAIN WATER LEADER
RECEIVING
REFRIGERATOR
REINFORCED / REINFORCING
REQUIRED
REVISION / REVISED
RISER
ROOF DRAIN
ROOM
SANITARY NAPKIN DISPENSER
SANITARY NAPKIN
SCHEDULE
SCUPPER
SECTION
SEISMIC JOINT
SERVICE SINK
SHEET
SHOWER/EYEWASH
SIMILAR
SOAP DISPENSER
SOUND TRANSMISSION CLASS
SPECIFICATIONS
SPLASH BLOCK
SQUARE
SQUARE INCH (S)
SQUARE YARD (S)
SQUARE FEET (FOOT)
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
STRUCTURAL GLAZED
FACING TILE
STRUCTURAL STEEL
SUSPEND, SUSPENSION
SURFACE
SYSTEM
TACKBOARD
TELEPHONE
TEMPERATURE / TEMPORARY
TOUNGE & GROOVE
THRESHOLD
THICK
TOILET
TOP OF
TREAD
TYPICAL
UNDERWRITER'S LABS
UNIT HEATER
UNIT VENTILATOR
UNLESS NOTED OTHERWISE
URINAL
VENT THROUGH ROOF
VERIFY IN FIELD
VERTICAL
VINYL ASBESTOS TILE
VINYL COMPOSITION TILE
WATER CLOSET
WATERPROOFING
WELDED WIRE FABRIC
WEIGHT
WHITE BOARD
WITH
WOOD
A.F.F.
A.F.G.
AC.,A.C.T.
A.C.
A.H.U.
ALT.
ALUM.
ANCH.
ABL
ANG
ANOD.
APPD.
ARCH.
ASB.
ASPH.
ASSY.
ASST
AUTO.
BM.
BRG.
BET.
BEV.
BIT.
BLK.
BLKG.
BD.
B/O
BTM.
BLDG.
B.U.R.
C.U.H.
CAP.
CLG.
CLG.HGT.
CEM.
CTR.
CL
CT
C.BD.
CH.
CLOS.
COL
CONF.
C.J.
CONT.
CONTR.
CORR.
CRS.
DAMPR.
DEG.
DEMO.
DEPT.
DET.
DIA.
DIM.
DIST.
DR.
DBL.
D.H.
DN.
D.S.
DWG.
D.F.
EA.
ELEC.
EWC.
EL.
ELEV.
EXFE
EMG.
EQ.
EQUIP.
EXIST.
ETR.
E.J.
EXT. EIFS.
FT.
FIN.
FD.
FEB
FEC
FE
FR.
FPRFG.
FIXT.
FLASH. FL.
FD.
FLR. FIN.
FTG.
FDN.
F.H.
FURN.
FURR
IN.
INCL.
INFO.
I.D.
INSUL.
INT.
JT.
KP.
LAB.
LAV.
LTG.
MACH.
MAINT.
MFR.
MBD.
MAS.
M.O.
MATL.
MAX.
MECH.
MET.
MEZZ.
MIN.
MISC.
OFF.
O.C.
O.H.
OPG.
O.D.
PTD.
PR.
P.T.D.
PERP.
PLAS.
P.LAM.
PL.
PLBG.
PLYWD.
P.C.
PREFAB.
PROJ. PT.
P.T.
QTY.
Q.T.
RAD.
RWL.
RECV.
REF.
REINF.
REQ'D.
REV.
R
R.D.
RM.
S.N.D.
S.N.R.
SCHED.
SC.
SECT.
S.J.
S.S.
SHT.
S/E
SIM.
S.D.
S.T.C.
SPEC.
S.B.
SQ.
SQ.IN.
SQ.YD.
S.F.
ST. STL.
STD.
STL.
STOR.
STRUCT.
SGFT.
STRUCT. STL.
SUSP.
SURF.
SYS.
TBD.
TEL.
TEMP.
T & G
THLD.
THK.
TLT
T/O
T.
TYP.
U.L.
U.H.
U.V.
U.N.O.
UR.
V.T.R.
V.I.F.
VERT.
V.A.T.
V.C.T.
W.C.
W.P.
W.W.F.
WT.
WBD.
W/
WD.
MATERIAL: 'R' VALUE
INSTALLED
.17OUTSIDE AIR
.44ASPHALT SHINGLE
.0630 POUND ROOFING FELT
8.6
3" POLYISO INSULATED NAIL BOARD
4" POLYISO INSULATION 24
0VAPOR BARRIER
ROOF R-VALUES
ROOFING SYSTEM
CLIMATE ZONE
WIND SPEED (APPENDIX P)
SURFACE ROUGHNESS
WIND CODE DATA
5A
Vault 135 mph
B
EXPOSURE CATEGORY
RISK CATEGORY (T 1604.5) III
Vasd 105 mph
HURRICANE PRONE REGION Yes
WIND BORNE DEBRIS REGION Yes
IMPORTANCE FACTOR Iw = 1.15
ASTM E1996 (1609.1.2.2) OPEN'G PROT'N N/A
ROOF DECK/ROOF COVERING (1609.5.1) ASCE 7
WIND CRITERIA (IECC 2021) (IBC 2021 CH 16)
0.122" PRECAST CONCRETE DECK
Total:
IECC 2021 (TC402.1.3) REQUIRED R 30 C.I.
R 33.39 C.I.
VARIES1/4" PER FOOT ROOF INSULATION BOARD
PROGRESS SET
NOT FOR
CONSTRUCTION
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
3/24/2026 4:00:58 PM
As indicated
R1.1
REFERENCE SHEET
NIANTIC
141 MAIN ST, NIANTIC
CT 06357
PATTAGANSETT
32A WEST MAIN STREET, NIANTIC
CT 06062
EL
SM
2024-128A
03/25/2026
NIANTIC AND
PATTAGANSETT PUMP
STATIONS ROOF
REPLACEMENT
Date of Original Construction
1. GROUP CLASSIFICATION
(Primary) (Incidental)
Renovation
Group U
N/A1987
CODE INFORMATION (NIANTIC)
IECC 2021 TABLE 402.1.3 - ZONE 5 AND MARINE 4
BUILDING ENVELOPE REQUIREMENTS -
OPAQUE ASSEMBLIES
N/A
MINIMUM REQUIRED CONDITION/VALUEELEMENT
ROOFS
R-30 ciINSULATION ENTIRELY ABOVE ROOF DECK
R-19 + R-11 LSMETAL BUILDINGS
R-49ATTIC AND OTHER
Date of Original Construction
1. GROUP CLASSIFICATION
(Primary) (Incidental)
Renovation
Group U
N/A1988
CODE INFORMATION (PATTAGANSETT)
N/A
REVISIONS
NO. DATE DESCRIPTION
03/25/2026 ISSUE FOR BID
13. SPRINKLER PROTECTION
Limited Area
Entire Building13. SPRINKLER PROTECTION
Limited Area
Entire Building
14. CODES TO WHICH THIS PROJECT WAS DESIGNED Dated:
NoYes15. THRESHOLD BUILDING CONDITIONS X
2021 International Building Code *
2021 International Mechanical Code *
2021 International Plumbing Code *
2021 International Energy Conservation Code *
2019 Installation of Sprinkler Systems (NFPA 13)
2021 Life Safety Code (NFPA 101) *
2021 Fire Code (NFPA 1) *
2021 International Residential Code *
2021 International Existing Building Code *
2017 Accessible and Usable Buildings and
Facilities (ICC A117.1-2017)*
2020 National Electrical Code (NFPA 70)*
2021 International Fire Code *
2021 International Swiming Pool & Spa Code *
* With Connecticut Amendments and General Statute requirements
14. CODES TO WHICH THIS PROJECT WAS DESIGNED Dated:
NoYes15. THRESHOLD BUILDING CONDITIONS X
2021 International Building Code *
2021 International Mechanical Code *
2021 International Plumbing Code *
2021 International Energy Conservation Code *
2019 Installation of Sprinkler Systems (NFPA 13)
2021 Life Safety Code (NFPA 101) *
2021 Fire Code (NFPA 1) *
2021 International Residential Code *
2021 International Existing Building Code *
2017 Accessible and Usable Buildings and
Facilities (ICC A117.1-2017)*
2020 National Electrical Code (NFPA 70)*
2021 International Fire Code *
2021 International Swiming Pool & Spa Code *
* With Connecticut Amendments and General Statute requirements
NoneXNoneX
'A'
'A'
'A'
'A'
'B'
'B'
STEEL NOTES:
ROOF VENTING PANEL SYSTEM FASTENER SCHEDULE
**COORDINATE DEPTH OF SYSTEM WITH ARCHITECT**
FASTENER LOCATION SPACING
SPILD-___ Within 48" of roof edge 12" o.c.
TRUFAST SIP by Altenloh, Brinck @ Co. US, Inc.
www.trufast.com
SPILD-___ Field 16" o.c.
PROGRESS SET
NOT FOR
CONSTRUCTION
SHEET NO.
21 Talcott Notch Road Farmington, CT 06032 friar.com 860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
3/9/2026 11:37:15 AM
As indicated
S1.1
ROOF FRAMING
OVERLAY PLAN
NIANTIC
NIANTIC
141 MAIN ST, NIANTIC
CT 06357
PATTAGANSETT
32A WEST MAIN STREET, NIANTIC
CT 06062
EL
SM
2024-128A
03/09/2026
NIANTIC AND
PATTAGANSETT PUMP
STATIONS ROOF
REPLACEMENT
SCALE: 1/4" = 1'-0"
NEW ROOF FRAMING OVERLAY PLAN - NIANTIC
REVISIONS
NO. DATE DESCRIPTION
SCALE: 3" = 1'-0"
B
DETAIL
SCALE: 1-1/2" = 1'-0"
A
SECTION
[**MAXIMUM UPLIFT PER CLIP: 450#]
03/25/2026 ISSUE FOR BID
Z:
\P
R O
JE
C
TS
\2
6\
1.
Fr ia r A rc hi te ct s
- N ia nt ic P um p
H ou se s
- R oo f O ve rla ys
\0 1_
D es ig n\
S1
N ia nt ic
_P at ta ga ns et t - R oo f O ve rla y.
dw g, /2 4/
:2
3:
P M
'A' 'A'
'A' 'A'
SLOPE
9.5/12
SLOPE
9.5/12
RIDGE
RIDGE
HV
HV
EV
RI
DG
E
SLOPE
9.5/12
SLOPE
9.5/12
'B'
'B'
STEEL NOTES:
ROOF VENTING PANEL SYSTEM FASTENER SCHEDULE
**COORDINATE DEPTH OF SYSTEM WITH ARCHITECT**
FASTENER LOCATION SPACING
SPILD-___ Within 48" of roof edge 12" o.c.
TRUFAST SIP by Altenloh, Brinck @ Co. US, Inc.
www.trufast.com
SPILD-___ Field 16" o.c.
PROGRESS SET
NOT FOR
CONSTRUCTION
SHEET NO.
21 Talcott Notch Road Farmington, CT 06032 friar.com 860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
3/9/2026 11:37:15 AM
As indicated
S1.2
ROOF FRAMING
OVERLAY PLAN
PATTAGANSETT
NIANTIC
141 MAIN ST, NIANTIC
CT 06357
PATTAGANSETT
32A WEST MAIN STREET, NIANTIC
CT 06062
EL
SM
2024-128A
03/09/2026
NIANTIC AND
PATTAGANSETT PUMP
STATIONS ROOF
REPLACEMENT
SCALE: 1/4" = 1'-0"
NEW ROOF FRAMING OVERLAY PLAN - PATTAGANSETT
REVISIONS
NO. DATE DESCRIPTION
SCALE: 3" = 1'-0"
B
DETAIL
SCALE: 1-1/2" = 1'-0"
A
SECTION
[**MAXIMUM UPLIFT PER CLIP: 450#]
03/25/2026 ISSUE FOR BID
Z:
\P
R O
JE
C
TS
\2
6\
1.
Fr ia r A rc hi te ct s
- N ia nt ic P um p
H ou se s
- R oo f O ve rla ys
\0 1_
D es ig n\
S1
N ia nt ic
_P at ta ga ns et t - R oo f O ve rla y.
dw g, /2 4/
:2
3:
M
NEW WORK LEGEND REFER TO SHEETS A2.3, A2.4 FOR ROOF
DETAILS & TYPICAL ROOF DETAILS
NEW ROOF, REFER TO TYPICAL ROOF SYSTEM DETAIL /1 A2.3
DS
ROOF DOWNSPOUT. SECURE TO FOOT OF BUILDING DAYLIGHT AT
GRADE
SPLASH BLOCK: BASIS OF DESIGN - 30" PRECAST CONCRETE SPLASH
BLOCK AS MANUFACTURED BY MODERN PRECAST, INC. PROVIDE ROOF
PROTECTION AS REQUIRED BY ROOF SYSTEM MANUFACTURER.
FACE OF BUILDING BELOW
X
A2.X
ROOF DETAIL LOCATION
REFER TO SHEET NO. A2.3, A2.4 FOR ROOF DETAILS
BEV BOX EXHAUST VENT, REFER TO ROOF DETAIL
EV EXHAUST VENT, REFER TO PENETRATION DETAIL /3 A2.3
HV HEAT VENT, REFER TO PENETRATION DETAIL /6 A2.3
SB
PHOTO REFERENCE
/9 A2.3
SLOPE
9.5 / 12
ROOF PITCH DIRECTION
V.I.F.
51'-5 1/2"
V.I.F.
8'-0"
HV
V .I
.F
V .I
.F
DS
NEW DOWNSPOUT, ROUTE
DOWN FACE OF WALL TO DRAIN
NEW DOWNSPOUT, ROUTE
DOWN FACE OF WALL TO DRAIN
SLOPE
9.5/12
SLOPE
9.5/12
SLOPE
9.5/12
SLOPE
9.5/12
EXTENT OF BUILDING
FOOTPRINT BELOW
EXTENT OF BUILDING
FOOTPRINT BELOW
A2.3
A2.3
A2.3
A2.3
A2.3
A2.4
A2.4
A2.4
A2.4
A2.4
A2.4
A2.4
NEW ROOF SYSTEM, REFER
TO TYPICAL DETAILS
NEW ROOF SYSTEM, REFER
TO TYPICAL DETAILS
HV
A2.4
SIM
A2.4
SIM
RIDGE
R
ID
G E
VALL
EY
VALLEY
R
ID
G E
VALL
EYVALLEY
BEV
SBSB
SB
REINSTALL TEMPORARY
REMOVED ANTENNA AS REQ'D
EV
NEW DOWNSPOUT, ROUTE
DOWN FACE OF WALL TO DRAIN
DS
GUTTER SLOPEGUTTER SLOPE
NEW 5" GUTTERS
NEW 5" GUTTER
NEW DOWNSPOUT, ROUTE
DOWN FACE OF WALL TO DRAIN
GUTTER SLOPE
DS
NEW 5" GUTTER
SB
GUTTER SLOPE
DS
V .I
.F
V.I.F.
59'-5 1/2"
S
LO
E
.5
/1
S
LO
/2 A2.1
/4 A2.1
HV EVBEV
SLOPE
9.5/12
SLOPE
9.5/12
SLOPE
9.5/12
2 2
HV, REMOVE PIPE UP TO
BOLTED CONNECTION TO
STAINLESS STEEL, REFER TO
INTERIOR PHOTOGRAPH 2
SLOPE
9.5/12
4S
LO
EXTENT OF BUILDING
FOOTPRINT BELOW
EXTENT OF BUILDING
FOOTPRINT BELOW
RIDGE
R
ID
G E
VALL
EY
VALLEY
R
ID
G E
VALL
EYVALLEY
.5
/1
/2 A2.1
/1 A2.1
TEMPORARY REMOVE EXISTING ANTENNA,
COVER AND STORE ON SITE TO
ACCOMMODATE NEW CONSTRUCTION AND
REINSTALL IN SAME THE LOCATION
REMOVE EXISTING GENERATOR
EXHAUST PIPE UP TO BOLTED
CONNECTION, PROVIDE NEW
STAINLESS STEEL EXAUST PIPE
ABOVE ROOF IN SIMILAR
CONFIGURATION DELEGATED
DESIGN V.I.F.
DEMOLITION KEYNOTES:
REMOVE EXISTING ROOFING SYSTEM DOWN TO STRUCTURAL
DECK, INCLUDING EXISTING SYNTHETIC SLATE SHINGLES, LEAD
COATED COPPER FLASHING AND 30" FELT. REMOVE ASSOCIATED
EDGE METAL AND ROOFING TERMINATIONS UNLESS OTHERWISE
NOTED, REMOVE EXISTING FASCIA BOARDS IN THEIR ENTIRETY.
EXISTING WOOD BLOCKING AND SOFFIT BOARDS TO REMAIN.
SEE HAZARDS MATERIALS REPORT
KEYED INTO PLAN
EXISTING EXHAUST VENT, BOX EXHAUST VENT AND HEAT VENT TO
REMAIN, REMOVE ROOFING SYSTEM AND ASSOCIATED FLASHING
REMOVE EXISTING ALUMINUM GUTTER/DOWNSPOUT AND
ASSOCIATED CLIPS IN IT'S ENTIRETY
3 REMOVE EXISTING VALLEY FLASHING AND RIDGE FLASHING
(NOT USED)
TEMPORARY REMOVE EXISTING ANTENNA, COVER AND STORE
ON SITE TO ACCOMMODATE NEW CONSTRUCTION AND
REINSTALL IN SAME THE LOCATION, REFER TO AND
/3 A2.1 /2 A2.2
1. ANY DEMOLITION WORK ASSOCIATED WITH NEW WORK THAT IS NOT SPECIFICALLY NOTED
ON THIS PLAN SHALL BE THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR.
2. DEMOLISHED MATERIAL SHALL BE CONSIDERED TO BE THE PROPERTY OF THE CONTRACTOR
AND SHALL BE COMPLETELY REMOVED FROM THE JOB SITE.
3. SHUT OFF, CAP AND OTHERWISE PROTECT EXISTING PUBLIC UTILITY LINES IN ACCORDANCE
WITH THE REQUIREMENTS OF THE PUBLIC AGENCY HAVING JURISDICTION.
4. COMPLETELY REMOVE ITEMS SCHEDULED TO BE SO DEMOLISHED AND REMOVE, LEAVING
SURFACES CLEAN, SOLID AND READY TO RECEIVE NEW MATERIALS AND SPECIFIED
ELSEWHERE.
5. USE MEANS NECESSARY TO PREVENT DUST FROM BECOMING A NUISANCE TO THE USER.
6. THIS DRAWING DOES NOT DEPICT THE FULL EXTENT OF DEMOLITION. ADDITIONAL ITEMS
SCHEDULED FOR DEMOLITION MAY BE FOUND ON OTHER DRAWINGS. GENERAL
CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK WITH ALL PARTIES
INVOLVED.
7. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL NATIONAL, STATE, LOCAL
CODES & ORDINANCES.
8. DEMOLITION CONTRACTOR MUST VERIFY LOCATIONS OF ALL EXISTING STRUCTURAL,
MECHANICAL, PLUMBING & ELECTRICAL ELEMENTS PRIOR TO START OF DEMOLITION.
9. REFER TO ALL DRAWINGS FOR ADDITIONAL INFORMATION.
10. THE DEMOLITION PLANS ARE DIAGRAMMATIC AND INTENDED TO SHOW THE GENERAL
EXTENT OF THE WORK ONLY.
11. THE CONTRACTOR SHALL INCLUDE ALL DEMOLITION WORK REQUIRED TO ACCOMPLISH THE
INTENT OF THE PLANS AND SPECIFICATIONS.
12. ALL DEMOLISHED ITEMS SHALL BE REMOVED FROM BUILDING /SITE UNLESS OTHERWISE
NOTED. COORDINATE WITH OWNER FOR DELIVERY OF ITEMS NOTED TO REMAIN OWNERS
PROPERTY. THE PROJECT SITE/ BUILDING SHALL BE CLEANED OF DEBRIS ON A DAILY BASIS.
GENERAL CONTRACTOR WILL COORDINATE AND INSTRUCT.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING AND SUPPORT (TEMPORARY OR
PERMANENT) FOR ALL PORTIONS OF CONSTRUCTION DURING DEMOLITION AND
CONSTRUCTION.
14. ALL ABANDONED MECHANICAL / ELECTRICAL / PLUMBING LINES SHALL BE CAPPED OFF
BEHIND FINISHES, UNLESS OTHERWISE NOTED.
15. GENERAL TRADES CONTRACTOR SHALL SAWCUT ALL MASONRY OR CONCRETE OPENINGS
INDICATED. MASONRY SHALL BE TOOTHED IN AND / OR RETURNED TO FINISHED OPENING.
ALL OPENINGS WHERE EXISTING CONSTRUCTION HAS BEEN REMOVED, AND WHICH ARE NOT
NOTED TO REMAIN, SHALL BE FILLED AND /OR PATCHED TO MATCH THE ADJACENT EXISTING
OR NEW FINISH, INCLUDING ANY FIRE RATINGS REQUIRED.
16. ALL AREAS OF FLOORS, WALLS AND CEILINGS DISTURBED BY DEMOLITION SHALL BE FILLED, PATCHED OR OTHERWISE REFINISHED TO MATCH EXISTING OR NEW FINISH AS DESIGNATED, INCLUDING ALL REQUIRED RATINGS.
17. COORDINATE DEMOLITION EFFORTS WITH ASBESTOS ABATEMENT WORK.
18. EXISTING CONDITIONS SHALL BE STUDIED PRIOR TO BIDDING TO FAMILIARIZE YOURSELF
WITH THE BUILDING AND INTENTIONS OF THE FINAL WORK AND THE REQUIRED
DEMOLITION, INCLUDING ALL MECH., ELECT., PLUMB., TECH., STRUCTURAL AND GENERAL
CONSTRUCTION ITEMS REQUIRING REMOVAL.
19. NO ELECTRICAL, TECHNOLOGY WIRING OR PNEUMATIC LINES ARE TO BE ABANDONED IN
PLACE.
20. REFER TO SPECS FOR CUTTING & PATCHING, AND SELECTIVE DEMOLTION.
GENERAL DEMOLITION NOTES
DEMOLITION LEGEND
ITEMS TO REMAIN
ITEMS TO BE DEMOLISHED
BEV BOX EXHAUST VENT
EV EXHAUST VENT
HEAT VENT
PHOTO REFERENCE
SLOPE
PITCH
ROOF PITCH/DIRECTION
FACE OF BUILDING BELOW
HV
PROGRESS SET
NOT FOR
CONSTRUCTION
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
3/24/2026 4:00:58 PM
As indicated
A2.1
ROOF PLANS -
NIANTIC
NIANTIC
141 MAIN ST, NIANTIC
CT 06357
PATTAGANSETT
32A WEST MAIN STREET, NIANTIC
CT 06062
EL
SM
2024-128A
03/25/2026
NIANTIC AND
PATTAGANSETT PUMP
STATIONS ROOF
REPLACEMENT
SCALE: 3/16" = 1'-0"
NEW ROOF PLAN - NIANTIC
SCALE: 3/16" = 1'-0"
DEMO ROOF PLAN - NIANTIC
REVISIONS
NO. DATE DESCRIPTION
03/25/2026 ISSUE FOR BID
SCALE:NTS
ANTENNA PHOTO REFERENCE
SCALE:NTS
INTERIOR PIPE PHOTO REFERENCE
SCALE: 3/4" = 1'-0"
STAINLESS STEEL PIPE REPLACEMENT
SLOPE
9.5/12
SLOPE
9.5/12
SLOPE
9.5/12
EXTENT OF BUILDING
FOOTPRINT BELOW
EXTENT OF BUILDING
FOOTPRINT BELOW
SLOPE
9.5/12
R
ID
G E
R
ID
G E
R
ID
G E
EXISTING EV TO
REMAIN
EXISTING HV
TO REMAIN
EXISTING HV TO
REMAIN
/1 A2.2
SLOPE
9.5/12
SLOPE
9.5/12
SLOPE
9.5/12
EXTENT OF BUILDING FOOTPRINT
BELOW
EXTENT OF BUILDING
FOOTPRINT BELOW
SLOPE
9.5/12
A2.3
A2.3
A2.4
A2.4
NEW ROOF SYSTEM, REFER
TO TYPICAL DETAILS
NEW ROOF SYSTEM, REFER
TO TYPICAL DETAILS
RIDGE
RIDGE
HV
REINSTALL TEMPORARY
REMOVED ANTENNA AS REQ'D
A2.3
R
ID
G E
HV
EV
NEW DOWNSPOUT, ROUTE
DOWN FACE OF WALL TO DRAIN
A2.4
NEW DOWNSPOUT, ROUTE
DOWN FACE OF WALL TO DRAIN
GUTTER SLOPE
NEW 5" GUTTER
GUTTER HIGH POINT
GUTTER SLOPE
NEW DOWNSPOUT, ROUTE
DOWN FACE OF WALL TO DRAIN
DS
SB
DS
SB
DS
GUTTER SLOPE
NEW 5" GUTTER
SB
DS
NEW DOWNSPOUT, ROUTE
DOWN FACE OF WALL TO DRAIN
GUTTER SLOPE
NEW 5" GUTTER
SB
A2.4
DS
DS
NEW DOWNSPOUT, ROUTE DOWN
FACE OF WALL TO DRAIN
G U
T T
E R
S
LO
P E
NEW 5" GUTTER
GUTTER HIGH POINT
G U
T T
E R
S
LO
P E
NEW DOWNSPOUT, ROUTE DOWN
FACE OF WALL TO DRAIN
SB
SB
V.I.F.
26'-4"
V.I.F.
14'-0" V.I.F.
40'-4"
V .I
.F
V .I
.F
V .I
.F
V .I
.F
TEMPORARY REMOVE EXISTING ANTENNA,
COVER AND STORE ON SITE TO
ACCOMMODATE NEW CONSTRUCTION AND
REINSTALL IN SAME THE LOCATION
DEMOLITION KEYNOTES:
REMOVE EXISTING ROOFING SYSTEM DOWN TO STRUCTURAL
DECK, INCLUDING EXISTING SYNTHETIC SLATE SHINGLES, LEAD
COATED COPPER FLASHING AND 30" FELT. REMOVE ASSOCIATED
EDGE METAL AND ROOFING TERMINATIONS UNLESS OTHERWISE
NOTED, REMOVE EXISTING FASCIA BOARDS IN THEIR ENTIRETY.
EXISTING WOOD BLOCKING AND SOFFIT BOARDS TO REMAIN.
SEE HAZARDS MATERIALS REPORT
KEYED INTO PLAN
EXISTING EXHAUST VENT, BOX EXHAUST VENT AND HEAT VENT TO
REMAIN, REMOVE ROOFING SYSTEM AND ASSOCIATED FLASHING
REMOVE EXISTING ALUMINUM GUTTER/DOWNSPOUT AND
ASSOCIATED CLIPS IN IT'S ENTIRETY
3 REMOVE EXISTING VALLEY FLASHING AND RIDGE FLASHING
(NOT USED)
TEMPORARY REMOVE EXISTING ANTENNA, COVER AND STORE
ON SITE TO ACCOMMODATE NEW CONSTRUCTION AND
REINSTALL IN SAME THE LOCATION, REFER TO AND
/3 A2.1 /2 A2.2
1. ANY DEMOLITION WORK ASSOCIATED WITH NEW WORK THAT IS NOT SPECIFICALLY NOTED
ON THIS PLAN SHALL BE THE RESPONSIBILITY OF THE DEMOLITION CONTRACTOR.
2. DEMOLISHED MATERIAL SHALL BE CONSIDERED TO BE THE PROPERTY OF THE CONTRACTOR
AND SHALL BE COMPLETELY REMOVED FROM THE JOB SITE.
3. SHUT OFF, CAP AND OTHERWISE PROTECT EXISTING PUBLIC UTILITY LINES IN ACCORDANCE
WITH THE REQUIREMENTS OF THE PUBLIC AGENCY HAVING JURISDICTION.
4. COMPLETELY REMOVE ITEMS SCHEDULED TO BE SO DEMOLISHED AND REMOVE, LEAVING
SURFACES CLEAN, SOLID AND READY TO RECEIVE NEW MATERIALS AND SPECIFIED
ELSEWHERE.
5. USE MEANS NECESSARY TO PREVENT DUST FROM BECOMING A NUISANCE TO THE USER.
6. THIS DRAWING DOES NOT DEPICT THE FULL EXTENT OF DEMOLITION. ADDITIONAL ITEMS
SCHEDULED FOR DEMOLITION MAY BE FOUND ON OTHER DRAWINGS. GENERAL
CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK WITH ALL PARTIES
INVOLVED.
7. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL NATIONAL, STATE, LOCAL
CODES & ORDINANCES.
8. DEMOLITION CONTRACTOR MUST VERIFY LOCATIONS OF ALL EXISTING STRUCTURAL,
MECHANICAL, PLUMBING & ELECTRICAL ELEMENTS PRIOR TO START OF DEMOLITION.
9. REFER TO ALL DRAWINGS FOR ADDITIONAL INFORMATION.
10. THE DEMOLITION PLANS ARE DIAGRAMMATIC AND INTENDED TO SHOW THE GENERAL
EXTENT OF THE WORK ONLY.
11. THE CONTRACTOR SHALL INCLUDE ALL DEMOLITION WORK REQUIRED TO ACCOMPLISH THE
INTENT OF THE PLANS AND SPECIFICATIONS.
12. ALL DEMOLISHED ITEMS SHALL BE REMOVED FROM BUILDING /SITE UNLESS OTHERWISE
NOTED. COORDINATE WITH OWNER FOR DELIVERY OF ITEMS NOTED TO REMAIN OWNERS
PROPERTY. THE PROJECT SITE/ BUILDING SHALL BE CLEANED OF DEBRIS ON A DAILY BASIS.
GENERAL CONTRACTOR WILL COORDINATE AND INSTRUCT.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING AND SUPPORT (TEMPORARY OR
PERMANENT) FOR ALL PORTIONS OF CONSTRUCTION DURING DEMOLITION AND
CONSTRUCTION.
14. ALL ABANDONED MECHANICAL / ELECTRICAL / PLUMBING LINES SHALL BE CAPPED OFF
BEHIND FINISHES, UNLESS OTHERWISE NOTED.
15. GENERAL TRADES CONTRACTOR SHALL SAWCUT ALL MASONRY OR CONCRETE OPENINGS
INDICATED. MASONRY SHALL BE TOOTHED IN AND / OR RETURNED TO FINISHED OPENING.
ALL OPENINGS WHERE EXISTING CONSTRUCTION HAS BEEN REMOVED, AND WHICH ARE NOT
NOTED TO REMAIN, SHALL BE FILLED AND /OR PATCHED TO MATCH THE ADJACENT EXISTING
OR NEW FINISH, INCLUDING ANY FIRE RATINGS REQUIRED.
16. ALL AREAS OF FLOORS, WALLS AND CEILINGS DISTURBED BY DEMOLITION SHALL BE FILLED, PATCHED OR OTHERWISE REFINISHED TO MATCH EXISTING OR NEW FINISH AS DESIGNATED, INCLUDING ALL REQUIRED RATINGS.
17. COORDINATE DEMOLITION EFFORTS WITH ASBESTOS ABATEMENT WORK.
18. EXISTING CONDITIONS SHALL BE STUDIED PRIOR TO BIDDING TO FAMILIARIZE YOURSELF
WITH THE BUILDING AND INTENTIONS OF THE FINAL WORK AND THE REQUIRED
DEMOLITION, INCLUDING ALL MECH., ELECT., PLUMB., TECH., STRUCTURAL AND GENERAL
CONSTRUCTION ITEMS REQUIRING REMOVAL.
19. NO ELECTRICAL, TECHNOLOGY WIRING OR PNEUMATIC LINES ARE TO BE ABANDONED IN
PLACE.
20. REFER TO SPECS FOR CUTTING & PATCHING, AND SELECTIVE DEMOLTION.
GENERAL DEMOLITION NOTES
DEMOLITION LEGEND
ITEMS TO REMAIN
ITEMS TO BE DEMOLISHED
BEV BOX EXHAUST VENT
EV EXHAUST VENT
HEAT VENT
PHOTO REFERENCE
SLOPE
PITCH
ROOF PITCH/DIRECTION
FACE OF BUILDING BELOW
HV
NEW WORK LEGEND REFER TO SHEETS A2.3, A2.4 FOR ROOF
DETAILS & TYPICAL ROOF DETAILS
NEW ROOF, REFER TO TYPICAL ROOF SYSTEM DETAIL /1 A2.3
DS
ROOF DOWNSPOUT. SECURE TO FOOT OF BUILDING DAYLIGHT AT
GRADE
SPLASH BLOCK: BASIS OF DESIGN - 30" PRECAST CONCRETE SPLASH
BLOCK AS MANUFACTURED BY MODERN PRECAST, INC. PROVIDE ROOF
PROTECTION AS REQUIRED BY ROOF SYSTEM MANUFACTURER.
FACE OF BUILDING BELOW
X
A2.X
ROOF DETAIL LOCATION
REFER TO SHEET NO. A2.3, A2.4 FOR ROOF DETAILS
BEV BOX EXHAUST VENT, REFER TO ROOF DETAIL
EV EXHAUST VENT, REFER TO PENETRATION DETAIL /3 A2.3
HV HEAT VENT, REFER TO PENETRATION DETAIL /6 A2.3
SB
PHOTO REFERENCE
/9 A2.3
SLOPE
9.5 / 12
ROOF PITCH DIRECTION
PROGRESS SET
NOT FOR
CONSTRUCTION
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
3/24/2026 4:00:58 PM
As indicated
A2.2
ROOF PLANS -
PATTAGANSETT
NIANTIC
141 MAIN ST, NIANTIC
CT 06357
PATTAGANSETT
32A WEST MAIN STREET, NIANTIC
CT 06062
EL
SM
2024-128A
03/25/2026
NIANTIC AND
PATTAGANSETT PUMP
STATIONS ROOF
REPLACEMENT
SCALE: 3/16" = 1'-0"
DEMO ROOF PLAN - PATTAGANSETT
SCALE: 3/16" = 1'-0"
NEW ROOF PLAN - PATTAGANSETT
REVISIONS
NO. DATE DESCRIPTION
03/25/2026 ISSUE FOR BID
SCALE:NTS
ANTENNA PHOTO REFERENCE
EXISTING CONSTRUCTION TO
REMAIN SHOWN SHADED
RIDGE CAP SHINGLE
PREFABRICATED ROOF RIDGE VENT
TYPICAL ROOFING SYSTEM, REFER
TO DETAIL
2" MIN.
/1 A2.3
EXISTING 2" PRECAST CONC. ROOF DECK
PLANKS
4" BASE RIGID INSULATION, STAGGER SEAMS W/
INSULATION ABOVE, PROVIDE EXPANSION FOAM IN
ALL SEAMS BETWEEN INSULATION PANELS
CONTINUOUS SELF ADHERING AIR VAPOR
BARRIER
3" PREFABRICATED VENTED NAILABLE
INSULATION PANEL
5/8" PLYWOOD
1" AIRSPACE
RIGID INSULATION
TYPICAL ASPHALT SHINGLE ASSEMBLY
ASPHALT SHINGLES
SELF ADHERING SHEET UNDERLAYMENT
(ENTIRE ROOF)
SEE ROOF R-VALUES R1.1 FOR CODE
INSULATION REQUIREMENT
Z-PURLIN, REFER TO STRUCTURAL
DRAWINGS FOR FASTENING REQUIREMENTS
SCOPE OF NEW WORK
PIPE PENETRATION THROUGH
ROOF
FULLY SEAL CIRCUMFERENCE, TYPICAL
LAP METAL COLLAR FLASHING
ONTO SURFACE OF SHINGLE
AND SEAL AS RECOMMENDED
BY MFG.
DRAWBAND SET IN
ELASTOMERIC MASTIC, TYPICAL
TYPICAL ROOFING SYSTEM,
REFER TO DETAIL /1 A2.3
BACKER ROD AND SEALANT AT
PIPE PERIMETER, TYPICAL
METAL COLLAR FLASHING
LAP METAL COLLAR FLASHING BELOW
SELF ADHERING SHEET UNDERLAYMENT,
SEAL AS RECOMMENDED BY MFG.
METAL COLLAR FLASHING
5 5/8"
1"
PER M
FR.
PER MFR.
SELF ADHERING SHEET
UNDERLAYMENT FLASHING
ENTIRE ROOF, TYP.
ROOF SHEATHING
9" STARTER STRIP SHINGLE
START FIRST COURSE WITH FULL STRIP
START SECOND COURSE WITH
FULL STRIP MINUS 1/2 TAB
START THIRD COURSE WITH FULL
STRIP MINUS FIRST TAB
METAL DRIP EDGE APPLIED OVER SELF
ADHERING SHEET UNDERLAYMENT AT
RAKE, TYP.
NAILING
METAL DRIP EDGE APPLIED
UNDER SELF ADHERING SHEET
UNDERLAYMENT AT EAVE, TYP.
SELF ADHERING SHEET
UNDERLAYMENT TO THE FULL
ROOF, LAP ALL SEAMS
ROOF SHEATHING VALLEY CENTERLINE
EXTEND SHINGLES 12" PAST
VALLEY CENTERLINE MIN.
NO FASTENERS WITHIN 6"
OF VALLEY CENTERLINE
EXTEND SELF ADHERING SHEET
UNDERLAYMENT UP FACE OF METAL
ROOF CURB TYPICAL AT ALL SIDES
METAL FLASHING TO EXTEND OVER
ROOF SHINGLES
PRE-MANUFACTURED MECHANICAL
CURB
WOOD BLOCKING
RIGID INSULATION
SEALANT, RECOMMENDED BY MFG
STAINLESS STEEL CURB COVER
METAL COLLAR FLASHING, SECURE WITH
DRAWBAND SET IN ELASTOMERIC
MASTIC AND SEAL WITH CONTINUOUS
BEAD OF APPROVED SEALANT
SEALANT, RECOMMENDED BY MFG
PIPE PENETRATION THROUGH ROOF
3/4" FIRE RETARDANT PLYWOOD
TYPICAL ROOFING SYSTEM,
REFER TO DETAIL /1 A2.3
LAP METAL COLLAR FLASHING BELOW
SELF ADHERING SHEET UNDERLAYMENT,
SEAL AS RECOMMENDED BY MFG.
VARIES
V A
R
IE
S
INSECT SCREEN
ASPHALT SHINGLES
METAL VENT COVER AND VENT
STACK
FLANGE LAPPED WITH
SHINGLES
SELF ADHERING SHEET
UNDERLAYMENT
LAP METAL COLLAR
FLASHING BELOW SELF
ADHERING SHEET
UNDERLAYMENT, SEAL AS
RECOMMENDED BY MFG.
12"MAX.
M
IN
SELF ADHERING SHEET UNDERLAYMENT
AT FULL ROOF, FULLY LAP SELF
ADHERING SHEET UNDERLAYMENT @
ROOF EDGE
FASTENERS,
AS NECESSARY
SELF ADHERING SHEET
UNDERLAYMENT
FLASHING 36" MIN. FROM
ROOF EDGE
ASPHALT SHINGLESREPLACE WOOD SHINGLE SIDING
AS REQUIRED FOR NEW METAL
STEP FLASHING, TYPICAL
NEW METAL STEP FLASHING,
TYPICAL, MAINTAIN 8" MIN.
FLASHING HEIGHTS
8"
STEP FLASHING LAP AS REQ'D
SELF ADHERING SHEET
UNDERLAYMENT AT FULL
ROOF, RUN VERTICALLY UP
WALL 8" MIN.
8"
TYPICAL ROOFING SYSTEM,
REFER TO DETAIL /1 A2.3
V A
R
IE
S
VARIES
PROGRESS SET
NOT FOR
CONSTRUCTION
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
3/24/2026 4:00:59 PM
As indicated
A2.3
TYPICAL DETAILS
NIANTIC
141 MAIN ST, NIANTIC
CT 06357
PATTAGANSETT
32A WEST MAIN STREET, NIANTIC
CT 06062
EL
SM
2024-128A
03/25/2026
NIANTIC AND
PATTAGANSETT PUMP
STATIONS ROOF
REPLACEMENT
SCALE: 1 1/2" = 1'-0"
RIDGE VENT DETAIL
SCALE: 1 1/2" = 1'-0"
TYPICAL ROOF SYSTEM
SCALE: 1/2" = 1'-0"
FLASHING AXONOMETRIC DETAIL
REVISIONS
NO. DATE DESCRIPTION
03/25/2026 ISSUE FOR BID
SCALE: 1 1/2" = 1'-0"
EXHAUST VENT PIPE PENETRATION DETAIL
SCALE: 1/2" = 1'-0"
FLASHING AXONOMETRIC DETAIL
SCALE: 1/2" = 1'-0"
TYPICAL WOVEN VALLEY DETAIL
SCALE: 1 1/2" = 1'-0"
HEAT VENT CURB DETAIL
SCALE: 3" = 1'-0"
BOX EXHAUST VENT DETAIL
SCALE: 1" = 1'-0"
STEP FLASHING DETAIL
EXISTING CONSTRUCTION TO
REMAIN SHOWN SHADED
3/4" CELLULAR PVC TRIM
PREFABRICATED EAVE VENT
FORMED 5" METAL GUTTER,
DOWNSPOUT, AND BRACKETS, REFER
TO ROOF PLAN FOR LOCATIONS
WOOD BLOCKING, TYPICAL AT ROOF
EDGE
TYPICAL ROOFING SYSTEM, REFER
TO DETAIL
METAL DRIP EDGE, LAP UNDER SELF
ADHERING SHEET UNDERLAYMENT
AT EAVE
/1 A2.3
/2
/4
3/4" CDX GRADE PLYWOOD
M
IN
3 3/4" 1 1/2"
1/2" M
IN.
1/
2" M
IN
1X WOOD BLOCKING AS REQUIRED
ATTACHMENT OF FACIAL
NEW WOOD BLOCKING MATCH
EXISTING V.I.F.
METAL DRIP EDGE, LAP UNDER
SELF ADHERING SHEET
UNDERLAYMENT AT EAVE
PREFABRICATED EAVE VENT
FORMED 5" METAL GUTTER,
DOWNSPOUT, AND BRACKETS,
REFER TO ROOF PLAN FOR
LOCATIONS
3/4" CELLULAR PVC TRIM
WOOD BLOCKING, TYPICAL AT
ROOF EDGE
3/4" CELLULAR PVC TRIM
EXISTING CONSTRUCTION TO
REMAIN SHOWN SHADED
TYPICAL ROOFING SYSTEM,
REFER TO DETAIL
M
IN
3/4" CDX GRADE PLYWOOD
/1 A2.3
/4
/2
1 1/2" 3 3/4"
1 1/2" M
IN
.1
1/2
" M
IN
1X WOOD BLOCKING AS
REQUIRED ATTACHMENT OF
FACIAL
NEW WOOD BLOCKING MATCH
EXISTING V.I.F.
FORMED 5" WIDE METAL
GUTTER, DOWNSPOUT, AND
BRACKETS, REFER TO ROOF
PLAN FOR LOCATIONS
WOOD BLOCKING, TYPICAL
AT ROOF EDGE
3/4" CELLULAR PVC TRIM
EXISTING CONSTRUCTION
TO REMAIN SHOWN SHADED
TYPICAL ROOFING SYSTEM,
REFER TO DETAIL
METAL DRIP EDGE, LAP
UNDER SELF ADHERING SHEET
UNDERLAYMENT AT EAVE
3/4" CELLULAR PVC TRIM
1/2 " M
IN
PREFABRICATED EAVE VENT
3/4" CDX GRADE PLYWOOD
/1 A2.3
M
IN
1 1/2" M
IN
1 1/2" 3 3/4"
/4
/4
/4
NEW WOOD BLOCKING
MATCH EXISTING V.I.F.
1X WOOD BLOCKING AS
REQUIRED ATTACHMENT OF
FACIAL
EXISTING CONSTRUCTION TO
REMAIN SHOWN SHADED
3/4" CELLULAR PVC TRIM
WOOD BLOCKING, TYPICAL
AT ROOF EDGE
METAL DRIP EDGE, LAP OVER
SELF ADHERING SHEET
UNDERLAYMENT AT RAKE
TYPICAL ROOFING SYSTEM,
REFER TO DETAIL /1 A2.3
/1 A2.3
EXISTING CONSTRUCTION TO REMAIN
SHOWN SHADED
TYPICAL ROOFING SYSTEM, REFER
TO DETAIL
CONTINUOUS BEAD OF SEALANT
M
IN
METAL FLASHING, MAINTAIN 8"
MINIMUM FLASHING DISTANCE UNLESS
OTHERWISE NOTED
LAP FLASHING ONTO SHINGLE SURFACE
AND ADHERE WITH ROOFING CEMENT
SAW CUT NEW REGLET INTO
MASONRY GROUT AS REQUIRED
REFER TO TYPICAL FLASHING DETAILS
/5 A2.3 /5 A2.4
AT SIDE WALL, EXTEND FLASHING
TO UNDERSIDE OF SOFFIT AND
SEAL WITH CONTINUOUS BEAD OF
APPROVED SEALANT
AT HEADWALL EXTEND FLASHING
TO BROWNSTONE MORTAR JOINT
AND CUT NEW REGLET TO
TERMINATE FLASHING
3/4" CELLULAR PVC TRIM
METAL DRIP EDGE, LAP OVER SELF
ADHERING SHEET UNDERLAYMENT
AT RAKE
WOOD BLOCKING, TYPICAL AT
ROOF EDGE
EXISTING CONSTRUCTION TO
REMAIN SHOWN SHADED
TYPICAL ROOFING SYSTEM,
REFER TO DETAIL /1 A2.3
M
IN
1 1/2"
PROGRESS SET
NOT FOR
CONSTRUCTION
SHEET NO.
PROFESSIONAL SEAL
21 Talcott Notch Road
Farmington, CT 06032 friar.com
860.678.1291
CONSULTANT
DATE:
SCALE
PROJ. #:
DRAWN:
CHECKED:
3/24/2026 4:01:00 PM
As indicated
A2.4
NIANTIC AND
PATTAGANSETT
ROOF DETAILS
NIANTIC
141 MAIN ST, NIANTIC
CT 06357
PATTAGANSETT
32A WEST MAIN STREET, NIANTIC
CT 06062
EL
SM
2024-128A
03/25/2026
NIANTIC AND
PATTAGANSETT PUMP
STATIONS ROOF
REPLACEMENT
SCALE: 1 1/2" = 1'-0"
TYPICAL EAVE EDGE DETAIL (STONE)
SCALE: 1 1/2" = 1'-0"
TYPICAL EAVE EDGE DETAIL (BRICK)
SCALE: 1 1/2" = 1'-0"
TYPICAL EAVE EDGE DETAIL (SHINGLE)
SCALE: 1 1/2" = 1'-0"
TYPICAL RAKE EDGE DETAIL (SHINGLE)
REVISIONS
NO. DATE DESCRIPTION
03/25/2026 ISSUE FOR BID
PATTAGANSETT ROOF DETAILS
NIANTIC ROOF DETAILS
SCALE: 1 1/2" = 1'-0"
BASE TIE IN DETAIL @ MASONRY WALL
SCALE: NTS
FLASHING DIAGRAM
SCALE: 1 1/2" = 1'-0"
TYPICAL RAKE EDGE DETAIL
SCALE: NTS
FLASHING DIAGRAM
REMOVE AND REINSTALL EXISTING CEDAR
SHAKE SIDING AS REQUIRED TO INSTALL
NEW STEP FLASHING PER TYPICAL DETAILS
TYPICAL OF (2) CONDITIONS
| Sheets |
| A2.1 - ROOF PLANS - NIANTIC |
| A2.2 - ROOF PLANS - PATTAGANSETT |
| A2.3 - TYPICAL DETAILS |
| A2.4 - NIANTIC AND PATTAGANSETT ROOF DETAILS |
| C1 - COVER SHEET |
| R1.1 - REFERENCE SHEET |
File details come from the government source that posted it. Updated .