2025.08.11_OCAT-WRWA_OKC MULTI-HANGAR PAINTING_100 CD_DRAWINGS.pdf
PDF 22 MB Posted
- Attached to
- Multi-Hangar Painting
- Solicitation number
- OCAT-OKC-2537
- Issued by
- Oklahoma County, Oklahoma City, Oklahoma
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Anti Noncollusion Affidavit.pdf | ||
| Project manual_Bidnet.pdf | ||
| Business Relationship Affidavit.pdf | ||
| MULTI-HANGAR PAINTING_Special Questionaire.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Frankfurt-Short-Bruza Associates, P.C.
5801 Broadway Extension, Suite 500
Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
STATE:
ARCHITECTURE CERTIFICATE OF AUTHORIZATION
ARCH ENTITY ID #
EXP.
OKC Will Rogers International Airport Multi-Hangar Painting
Project No. OCAT OKC 2537
FS
B2
4- 8- P ro jec t N o.
OC
AT
O
KC
OKLAHOMA CITY, OKLAHOMA
CONSTRUCTION DOCUMENTS
AUGUST 28, 2025
00199 06/30/2027
OKLAHOMA
SHEET INDEX
NUMBER TITLE
GENERAL
G-001 COVER SHEET
ARCHITECTURE
A-001 ABBREVIATIONS AND SYMBOLS
AS100 ARCHITECTURAL SITE PLAN
AE101 HANGAR 1C
AE102 HANGAR 1B
AE103 HANGAR 1
AE104 HANGAR 2
AE105 HANGAR 3
AE106 HANGAR 3A
AE107 HANGAR 3B
SCALE: NTS
N
VICINITY MAP1 SCALE: NTS
N
AREA MAP2
OKLAHOMA CITY
INTERNATIONAL AIRPORT HANGARS 1C, 1B, 1, 2, 3, 3A, AND 3B
MARK E.
TIMBROOK
A08626
AE 101
DRAWING TYPES LEGEND
0- GENERAL INFORMATION
1 - PLANS (HORIZONTAL VIEWS)
2 - ELEVATIONS (VERTICAL VIEWS)
3 - SECTIONS (SECTIONAL VIEWS)
4 - ENLARGED VIEWS (PLANS, ELEVATIONS OR SECTIONS)
5 - DETAILS
6 - SCHEDULES & DIAGRAMS
DISCIPLINE TYPE (ARCHITECTURE SHOWN)
DRAWING TYPE (PLAN, ELEVATION, ETC.)
SERIES/ FLOOR DESIGNATION
DETAIL CALLOUT
ENLARGED PLAN OR DETAIL ON
SHEET INDICATED
INTERIOR ELEVATION CALLOUT
ARROW INDICATES INTERIOR ELEVATION
ON SHEET INDICATED
STRUCTURAL GRIDS
AS INDICATED ON DRAWINGS
BUILDING SECTION CALLOUT
ARROWS INDICATE BUILDING SECTION ON
SHEET INDICATED
A301
SECTION CALLOUT
ARROW INDICATE WALL SECTION ON SHEET
INDICATED
A302
ROOM NAME & NUMBER SYMBOL
REFER TO ROOM FINISH SCHEDULE
1A
DOOR NUMBER SYMBOL
REFER TO DOOR SCHEDULE
DOOR NUMBER WITH * INDICATES
ACCESS CONTROL HARDWARE
PARTITION TYPE SYMBOL
REFER TO PARTITION TYPES
GLAZING TYPE SYMBOL
REFER TO GLAZING TYPES
A
AL1
REVISION SYMBOL
REFER TO SHEET BORDER FOR REVISION
HISTORY
ELEVATION DATUM SYMBOL
INDICATES DATUM ELEVATION AS INDICATED
DISCIPLINE MODIFIER (ELEMENTS SHOWN)
ARCHITECTURAL SYMBOLS LEGEND
DRAWING TITLE
NORTH ARROW
A301
EXTERIOR ELEVATION
ARROW INDICATE ELEVATION ON SHEET
INDICATED
112.01A
SUB-ROOM NUMBER
FLOOR LEVEL
KEYNOTE SYMBOL
INDICATES INFORMATION FOUND
IN KEYNOTES ON PLAN
3 DIGIT ROOM NUMERAL
OFFICE SUITE DESIGNATION
LOCATED NEXT TO THE
VIEW TITLE N
Bottom Text Top Text
A
A-401
SIM
PROJECT
KEYPLAN
A B
D C
TRUE NORTH
PLAN NORTH
KEYPLAN SYMBOL
INDICATES INFORMATION FOUND IN KEYNOTES ON
PLAN
SCALE:
View NameX 1/8" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
SCALE
xx
A301
ROOM NAME
M888
INTERIOR SECTION CALLOUT
ARROW INDICATES CASEWORK AND/OR
MILLWORK SECTION ON SHEET INDICATED
1/A301
A101
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADAAG ADA ACCESSIBILITY GUIDELINES
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
AJ AESTHETIC JOINT
ALT ALTERNATE
ALUM ALUMINUM
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APC ACOUSTICAL PANEL CEILING
ASI ARCHITECT'S SUPPLEMENTAL INFORMATION
AV AUDIO VISUAL
AWS ABOVE WALKING SURFACE
BLDG BUILDING
BO BOTTOM OF
BOT BOTTOM
BRG BEARING
BS BOTH SIDES
BTWN BETWEEN
CAB CABINET
CFMF COLD-FORMED METAL FRAMING
CG CORNER GUARD
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CPT CARPET
CTB CERAMIC TILE BASE
CTC CENTER TO CENTER
CTR CENTER
CU CUBIC
CWT CERAMIC WALL TILE
D DEPTH
DAT DATUM
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DET/DTL DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DN DOWN
DR DOOR
DS DOWNSPOUT
DWG DRAWING
E EAST
EA EACH
EIFS EXTERIOR INSULATION & FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC (OR) ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EXIST EXISTING
EXT EXTERIOR
FAAP FIRE ALARM ANNUNCIATOR PANEL
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FE FIRE EXTINGUISHER
FFE FINISH FLOOR ELEVATION
FG FINISHED GRADE
FH FIRE HYDRANT
FLR FLOOR
FLUOR FLUORESCENT
FPC FIRE PROTECTION CABINET
FR FIRE RESISTIVE
FRGB FIBER REINFORCED GYPSUM BOARD
FT FOOT (OR) FEET
FTG FOOTING
FURG FURRING
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GDR GUARD RAIL
GEN GENERAL
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS
GRD GRADE
GYM GYMNASIUM
GYP BD GYPSUM BOARD
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC "HEATING, VENTILATING, & AIR CONDITIONING"
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IN INCH(ES)
INSUL INSULATE (OR) INSULATION
INT INTERIOR
JAN JANITOR
JT JOINT
KIT KITCHEN
LAM LAMINATE
LAV LAVATORY
LBS POUND(S)
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LIB LIBRARY
LIN LINEAR
LOC LOCATION
LTG LIGHTING
LVR LOUVER
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEP "MECHANICAL, ELECTRICAL, PLUMBING"
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MJ MASONRY EXPANSION JOINT
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
N NORTH
NA NOT APPLICABLE
NC NOISE CRITERIA
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OFS OUTSIDE FACE OF STUDS
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPT OPTIONAL
ORD OVERFLOW ROOF DRAIN
OVHD OVERHEAD
OZ OUNCE(S)
PCI PRECAST / PRESTRESSED CONCRETE INSTITUTE
PEMB PRE-ENGINEERED METAL BUILDING
PH PHASE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT (INTERIOR)
PVC POLYVINYL CHLORIDE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTY QUANTITY
R RADIUS (OR) RISER
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFERENCE
REBAR REINFORCING STEEL BARS
REC RECESSED
REF REFERENCE (OR) REFRIGERATOR
REINF REINFORCED
REQD REQUIRED
REV REVISION
RF RESILIENT FLOORING
RFI REQUEST FOR INTERPRETATION
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
RTU ROOF TOP UNIT
S SOUTH
SC SOLID CORE
SCHED SCHEDULE(D)
SECT SECTION
SF SQUARE FOOT (FEET)
SHTHG SHEATHING
SIM SIMILAR
SPEC SPECIFICATION(S)
SQ SQUARE
SST STAINLESS STEEL
STC SOUND TRANSMISSION CLASSIFICATION
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL (OR) STRUCTURE
T TREAD
T&B TOP AND BOTTOM
TBD TO BE DETERMINED
TD TOWEL DISPENSER
TEMP TEMPORARY
THK THICKNESS (THICK)
THRES THRESHOLD
THRU THROUGH
TO TOP OF
TOB TOP OF BEAM
TOC TOP OF CONCRETE
TOJ TOP OF JOIST
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TV TELEVISION
TYP TYPICAL
UC UNDER COUNTER
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
VAR VARIES
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VER VERIFY
VERT VERTICAL
VOL VOLUME
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WH WALL HYDRANT (OR) WATER HEATER
WT WEIGHT
XFMR TRANSFORMER
YD YARD
ARCHITECTURAL ABBREVIATIONS
A
B
C
D
1 2 3 4 5
A
B
C
D
1 2 3 4 5
SHEET NUMBER
ISSUE DATE
REVISION HISTORY
PROJECT INFORMATION
DRAWN BY:
DESIGNED BY: REVIEWED BY:
PROJECT MANAGER:
PROJECT NUMBER
SHEET TITLE:
Frankfurt-Short-Bruza Associates, P.C.
5801 Broadway Extension, Suite 500
Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
6" 1'-6"1'0
1 1/2" = 1'-0"
0 6" 1' 2'
1" = 1'-0"
0 1' 2' 4'
1/2" = 1'-0"
0 2' 4' 8'
1/4" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
0 8' 16' 32'
1/16" = 1'-0"
3" 9"6"0
3" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
2' 6'4'0
3/8" = 1'-0"
4' 12'8'0
3/16" = 1'-0"
8' 24'16'0
3/32" = 1'-0"
O K C W ill R og er s In te rn at io na l A irp or t
0 50' 100' 200'
1" = 100'-0"
8/11/2025 4:30:53 PM
C
:\M yR evit\415814-O C
AT_M
M
AC
- PAIN
T H
AN
G
AR
S-A-24_dm onkR
T9D X.rvt
PDC
PDC RLM
ABBREVIATIONS AND SYMBOLS
AUGUST 28, 2025
A-001
M ul ti- H an ga r P ai nt in g
Pr oj ec t N o.
O C A T O K C
O K
LA
H O M A C
IT
Y, O K
LA
H O M A
PU
T YO
U R
C
EN
TR
AL FILE PATH
H
ER
E
CAW
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
FSB2024-158-14
Architectural CoA - 00199 Exp. 06/30/2027
DESCRIPTION DATE
MARK E.
1C
1B
3A
3B
ME
RI
DI
AN
A
VE
SW 66TH ST
SW 67TH ST
GUY FULLER DR
TERMINAL DR
NOT IN SCOPE
SCOPE OF WORK LEGEND
IN SCOPE (BUILDING TO BE REPAINTED)
A
B
C
D
1 2 3 4 5
A
B
C
D
1 2 3 4 5
SHEET NUMBER
ISSUE DATE
REVISION HISTORY
PROJECT INFORMATION
DRAWN BY:
DESIGNED BY: REVIEWED BY:
PROJECT MANAGER:
PROJECT NUMBER
SHEET TITLE:
Frankfurt-Short-Bruza Associates, P.C.
5801 Broadway Extension, Suite 500
Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
6" 1'-6"1'0
1 1/2" = 1'-0"
0 6" 1' 2'
1" = 1'-0"
0 1' 2' 4'
1/2" = 1'-0"
0 2' 4' 8'
1/4" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
0 8' 16' 32'
1/16" = 1'-0"
3" 9"6"0
3" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
2' 6'4'0
3/8" = 1'-0"
4' 12'8'0
3/16" = 1'-0"
8' 24'16'0
3/32" = 1'-0"
O K C W ill R og er s In te rn at io na l A irp or t
0 50' 100' 200'
1" = 100'-0"
8/11/2025 4:30:54 PM
C
:\M yR evit\415814-O C
AT_M
M
AC
- PAIN
T H
AN
G
AR
S-A-24_dm onkR
T9D X.rvt
PDC
PDC RLM
ARCHITECTURAL SITE PLAN
AUGUST 28, 2025
AS100
M ul ti- H an ga r P ai nt in g
Pr oj ec t N o.
O C A T O K C
O K
LA
H O M A C
IT
Y, O K
LA
H O M A
PU
T YO
U R
C
EN
TR
AL FILE PATH
H
ER
E
CAW
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
FSB2024-158-14
Architectural CoA - 00199 Exp. 06/30/2027
SCALE:
N
1" = 100'-0"
ARCHITECTURAL SITE PLAN1
DESCRIPTION DATE
MARK E.
PT-1 PT-1
FV
± 3 4'-
6"
PT-1
FV
± 3 4'-
6"
PT-1
FV
± 1 2'-
0"
FV
± 3 6'-
0"
PT-1
FV± 9
'-0
VIEW #1
VIEW #3
VIEW #4
VIEW #2FV
± 215'-0"
FV
± 1 7'-
0"
FV
± 6 2'-
0"
FV
± 3 5'-
0"
FV
± 3 5'-
0"
FV
± 1 5'-
0"
FV
± 45'-0"
FV
± 12'-0"
A.
B.
C.
D.
ALL PREVIOUSLY PAINTED SURFACES SHALL BE PAINTED
INCLUDING BUT NOT LIMITED TO WALLS, DOORS, HIGH BAY
HANGAR DOORS, GUTTERS AND DOWNSPOUTS, PARAPETS,
SOFFITS, OUT BUILDINGS, AWNINGS, LOUVERS, TRIMS, ROOF
MECHANICAL EQUIPMENT AND SUITES, DUCTWORK, HAND/GUARD
RAILS, CAMERA MOUNTS, ROOF HATCHES, STRUCTURAL
SUPPORTS AND COLUMNS
ALL EXTERIOR WALL PENETRATIONS, WINDOWS, SIGNAGE,
EXTERIOR LIGHT FIXTURES, AND FOLIAGE SHALL BE PROPERLY
MASKED AND PROTECTED PRIOR TO PAINTING.
SCREENING SHALL BE USED IN AREAS WHERE THERE IS RISK
FOR CARS TO BE DAMAGED BY OVERSPRAY.
WHERE APPLICABLE, PAINTED ON BUILDING NUMBERS SHALL BE
MASKED AND REPAINTED.
A
B
C
D
1 2 3 4 5
A
B
C
D
1 2 3 4 5
SHEET NUMBER
ISSUE DATE
REVISION HISTORY
PROJECT INFORMATION
DRAWN BY:
DESIGNED BY: REVIEWED BY:
PROJECT MANAGER:
PROJECT NUMBER
SHEET TITLE:
GENERAL NOTES
KEYPLAN
1B
1C
Frankfurt-Short-Bruza Associates, P.C.
5801 Broadway Extension, Suite 500
Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
6" 1'-6"1'0
1 1/2" = 1'-0"
0 6" 1' 2'
1" = 1'-0"
0 1' 2' 4'
1/2" = 1'-0"
0 2' 4' 8'
1/4" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
0 8' 16' 32'
1/16" = 1'-0"
3" 9"6"0
3" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
2' 6'4'0
3/8" = 1'-0"
4' 12'8'0
3/16" = 1'-0"
8' 24'16'0
3/32" = 1'-0"
3A
3B
O K C W ill R og er s In te rn at io na l A irp or t
0 50' 100' 200'
1" = 100'-0"
8/11/2025 4:30:56 PM
C
:\M yR evit\415814-O C
AT_M
M
AC
- PAIN
T H
AN
G
AR
S-A-24_dm onkR
T9D X.rvt
PDC
PDC RLM
HANGAR 1C
AUGUST 28, 2025
AE101
M ul ti- H an ga r P ai nt in g
Pr oj ec t N o.
O C A T O K C
O K
LA
H O M A C
IT
Y, O K
LA
H O M A
PU
T YO
U R
C
EN
TR
AL FILE PATH
H
ER
E
CAW
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
FSB2024-158-14
Architectural CoA - 00199 Exp. 06/30/2027
SCALE: NTS
HANGAR 1C - SOUTH FACE3
SCALE: NTS
HANGAR 1C - NORTH FACE1
SCALE: NTS
HANGAR 1C - EAST FACE4
SCALE: NTS
HANGAR 1C - ENTRANCE NORTH FACE2
SCALE: NTS
N
HANGAR 1C - AERIAL5
DESCRIPTION DATE
MARK E.
PT-1
FV
± 2 8'-
0"
FV± 8
'-0
FV± 8
'-0
FV
± 30'-0"
FV
± 25'-0"
PT-1
FV
± 3 4'-
0"
PT-1PT-1
PT-1
FV
± 2 0'-
0"
VIEW #1
VIEW #2
VIEW #3VIEW #4
FV
± 178'-0"
FV
± 22'-0"
FV
± 2
'-0
FV
± 1 0'-
0"
FV
± 1
'-0
FV
± 5 3'-
0"
FV
A.
B.
C.
D.
ALL PREVIOUSLY PAINTED SURFACES SHALL BE PAINTED
INCLUDING BUT NOT LIMITED TO WALLS, DOORS, HIGH BAY
HANGAR DOORS, GUTTERS AND DOWNSPOUTS, PARAPETS,
SOFFITS, OUT BUILDINGS, AWNINGS, LOUVERS, TRIMS, ROOF
MECHANICAL EQUIPMENT AND SUITES, DUCTWORK, HAND/GUARD
RAILS, CAMERA MOUNTS, ROOF HATCHES, STRUCTURAL
SUPPORTS AND COLUMNS
ALL EXTERIOR WALL PENETRATIONS, WINDOWS, SIGNAGE,
EXTERIOR LIGHT FIXTURES, AND FOLIAGE SHALL BE PROPERLY
MASKED AND PROTECTED PRIOR TO PAINTING.
SCREENING SHALL BE USED IN AREAS WHERE THERE IS RISK
FOR CARS TO BE DAMAGED BY OVERSPRAY.
WHERE APPLICABLE, PAINTED ON BUILDING NUMBERS SHALL BE
MASKED AND REPAINTED.
A
B
C
D
1 2 3 4 5
A
B
C
D
1 2 3 4 5
SHEET NUMBER
ISSUE DATE
REVISION HISTORY
PROJECT INFORMATION
DRAWN BY:
DESIGNED BY: REVIEWED BY:
PROJECT MANAGER:
PROJECT NUMBER
SHEET TITLE:
GENERAL SHEET NOTES
KEYPLAN
1B
1C
Frankfurt-Short-Bruza Associates, P.C.
5801 Broadway Extension, Suite 500
Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
6" 1'-6"1'0
1 1/2" = 1'-0"
0 6" 1' 2'
1" = 1'-0"
0 1' 2' 4'
1/2" = 1'-0"
0 2' 4' 8'
1/4" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
0 8' 16' 32'
1/16" = 1'-0"
3" 9"6"0
3" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
2' 6'4'0
3/8" = 1'-0"
4' 12'8'0
3/16" = 1'-0"
8' 24'16'0
3/32" = 1'-0"
3A
3B
O K C W ill R og er s In te rn at io na l A irp or t
0 50' 100' 200'
1" = 100'-0"
8/11/2025 4:30:56 PM
C
:\M yR evit\415814-O C
AT_M
M
AC
- PAIN
T H
AN
G
AR
S-A-24_dm onkR
T9D X.rvt
PDC
PDC RLM
HANGAR 1B
AUGUST 28, 2025
AE102
M ul ti- H an ga r P ai nt in g
Pr oj ec t N o.
O C A T O K C
O K
LA
H O M A C
IT
Y, O K
LA
H O M A
PU
T YO
U R
C
EN
TR
AL FILE PATH
H
ER
E
CAW
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
FSB2024-158-14
Architectural CoA - 00199 Exp. 06/30/2027
SCALE: NTS
HANGAR 1B - SOUTH FACE2
SCALE: NTS
HANGAR 1B - WEST FACE4
SCALE: NTS
HANGAR 1B - NORTH FACE1
SCALE: NTS
HANGAR 1B - EAST FACE3
SCALE: NTS
N
HANGAR 1B - AERIAL5
DESCRIPTION DATE
MARK E.
A.
B.
C.
D.
ALL PREVIOUSLY PAINTED SURFACES SHALL BE PAINTED
INCLUDING BUT NOT LIMITED TO WALLS, DOORS, HIGH BAY
HANGAR DOORS, GUTTERS AND DOWNSPOUTS, PARAPETS,
SOFFITS, OUT BUILDINGS, AWNINGS, LOUVERS, TRIMS, ROOF
MECHANICAL EQUIPMENT AND SUITES, DUCTWORK, HAND/GUARD
RAILS, CAMERA MOUNTS, ROOF HATCHES, STRUCTURAL
SUPPORTS AND COLUMNS
ALL EXTERIOR WALL PENETRATIONS, WINDOWS, SIGNAGE,
EXTERIOR LIGHT FIXTURES, AND FOLIAGE SHALL BE PROPERLY
MASKED AND PROTECTED PRIOR TO PAINTING.
SCREENING SHALL BE USED IN AREAS WHERE THERE IS RISK
FOR CARS TO BE DAMAGED BY OVERSPRAY.
WHERE APPLICABLE, PAINTED ON BUILDING NUMBERS SHALL BE
MASKED AND REPAINTED.
PT-1
FV
± 2 6'-
0"FV
± 3 6'-
0"
PT-1
PT-1
FV
± 1 4'-
0"
PT-1 PT-1
PT-1 PT-1 PT-1
FV
± 3 6'-
0"
FV
± 1 0'-
0"
FV± 9
'-6
VIEW #1
VIEW #2
VIEW #3
VIEW #4
VIEW #4
VIEW #5VIEW #5
VIEW #5
VIEW #5
FV
± 2
'-0
FV
± 230'-0"
FV
±5 2'-
0"
FV
± 1
'-0
FV
± 2
'-0
FV
± 2 5'-
0"
FV
± 6'-0"
FV
± 12'-0"
PT-1 PT-1
A
B
C
D
1 2 3 4 5
A
B
C
D
1 2 3 4 5
SHEET NUMBER
ISSUE DATE
REVISION HISTORY
PROJECT INFORMATION
DRAWN BY:
DESIGNED BY: REVIEWED BY:
PROJECT MANAGER:
PROJECT NUMBER
SHEET TITLE:
GENERAL SHEET NOTES
KEYPLAN
1B
1C
Frankfurt-Short-Bruza Associates, P.C.
5801 Broadway Extension, Suite 500
Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
6" 1'-6"1'0
1 1/2" = 1'-0"
0 6" 1' 2'
1" = 1'-0"
0 1' 2' 4'
1/2" = 1'-0"
0 2' 4' 8'
1/4" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
0 8' 16' 32'
1/16" = 1'-0"
3" 9"6"0
3" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
2' 6'4'0
3/8" = 1'-0"
4' 12'8'0
3/16" = 1'-0"
8' 24'16'0
3/32" = 1'-0"
3A
3B
O K C W ill R og er s In te rn at io na l A irp or t
0 50' 100' 200'
1" = 100'-0"
8/11/2025 4:30:58 PM
C
:\M yR evit\415814-O C
AT_M
M
AC
- PAIN
T H
AN
G
AR
S-A-24_dm onkR
T9D X.rvt
PDC
PDC RLM
HANGAR 1
AUGUST 28, 2025
AE103
M ul ti- H an ga r P ai nt in g
Pr oj ec t N o.
O C A T O K C
O K
LA
H O M A C
IT
Y, O K
LA
H O M A
PU
T YO
U R
C
EN
TR
AL FILE PATH
H
ER
E
CAW
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
FSB2024-158-14
Architectural CoA - 00199 Exp. 06/30/2027
SCALE: NTS
HANGAR 1 - WEST FACE3
SCALE: NTS
HANGAR 1 - SOUTH FACE1
SCALE: NTS
HANGAR 1 - EAST FACE2
SCALE: NTS
HANGAR 1 - WEST SURFACES5
SCALE: NTS
N
HANGAR 1 - AERIAL6
SCALE: NTS
HANGAR 1 - FRONT ENTRANCE4
DESCRIPTION DATE
MARK E.
C.
D.
ALL PREVIOUSLY PAINTED SURFACES SHALL BE PAINTED
INCLUDING BUT NOT LIMITED TO WALLS, DOORS, HIGH BAY
HANGAR DOORS, GUTTERS AND DOWNSPOUTS, PARAPETS,
SOFFITS, OUT BUILDINGS, AWNINGS, LOUVERS, TRIMS, ROOF
MECHANICAL EQUIPMENT AND SUITES, DUCTWORK, HAND/GUARD
RAILS, CAMERA MOUNTS, ROOF HATCHES, STRUCTURAL
SUPPORTS AND COLUMNS
ALL EXTERIOR WALL PENETRATIONS, WINDOWS, SIGNAGE,
EXTERIOR LIGHT FIXTURES, AND FOLIAGE SHALL BE PROPERLY
MASKED AND PROTECTED PRIOR TO PAINTING.
SCREENING SHALL BE USED IN AREAS WHERE THERE IS RISK
FOR CARS TO BE DAMAGED BY OVERSPRAY.
WHERE APPLICABLE, PAINTED ON BUILDING NUMBERS SHALL BE
MASKED AND REPAINTED.
PT-1
FV
± 2 2'-
6"
FV
FV± 8
'-0
PT-1
FV
± 1 1'-
6"FV
± 2 2'-
6"
PT-1
FV
± 1 2'-
0"
PT-1
PT-1
MASK BUILDING NUMBERS (TYP)
IN PREPARATION FOR PAINTING
VIEW #1
VIEW #2
VIEW #3
VIEW #4
VIEW #5 VIEW #5
VIEW #5 VIEW #5
VIEW #2
VIEW #1
FV
± 3 9'-
6"
FV
± 8 3'-
0"
FV
± 16'-0"
FV
± 13'-0"
FV
± 133'-6"
FV
± 29'-0"
FV
± 1
'-6
FV
± 191'-6"
A
B
C
D
1 2 3 4 5
A
B
C
D
1 2 3 4 5
SHEET NUMBER
ISSUE DATE
REVISION HISTORY
PROJECT INFORMATION
DRAWN BY:
DESIGNED BY: REVIEWED BY:
PROJECT MANAGER:
PROJECT NUMBER
SHEET TITLE:
GENERAL SHEET NOTES
KEYPLAN
1B
1C
Frankfurt-Short-Bruza Associates, P.C.
5801 Broadway Extension, Suite 500
Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
6" 1'-6"1'0
1 1/2" = 1'-0"
0 6" 1' 2'
1" = 1'-0"
0 1' 2' 4'
1/2" = 1'-0"
0 2' 4' 8'
1/4" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
0 8' 16' 32'
1/16" = 1'-0"
3" 9"6"0
3" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
2' 6'4'0
3/8" = 1'-0"
4' 12'8'0
3/16" = 1'-0"
8' 24'16'0
3/32" = 1'-0"
3A
3B
O K C W ill R og er s In te rn at io na l A irp or t
0 50' 100' 200'
1" = 100'-0"
8/11/2025 4:31:00 PM
C
:\M yR evit\415814-O C
AT_M
M
AC
- PAIN
T H
AN
G
AR
S-A-24_dm onkR
T9D X.rvt
PDC
PDC RLM
HANGAR 2
AUGUST 28, 2025
AE104
M ul ti- H an ga r P ai nt in g
Pr oj ec t N o.
O C A T O K C
O K
LA
H O M A C
IT
Y, O K
LA
H O M A
PU
T YO
U R
C
EN
TR
AL FILE PATH
H
ER
E
CAW
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
FSB2024-158-14
Architectural CoA - 00199 Exp. 06/30/2027
SCALE: NTS
HANGAR 2 - SOUTH FACE2
SCALE: NTS
HANGAR 2 - WEST FACE4
SCALE: NTS
HANGAR 2 - EAST FACE3
SCALE: NTS
HANGAR 2 - ROOF ELEMENTS5
SCALE: NTS
HANGAR 2 - NORTH FACE1
SCALE: NTS
N
HANGAR 2 - AERIAL6
DESCRIPTION DATE
MARK E.
C.
D.
ALL PREVIOUSLY PAINTED SURFACES SHALL BE PAINTED
INCLUDING BUT NOT LIMITED TO WALLS, DOORS, HIGH BAY
HANGAR DOORS, GUTTERS AND DOWNSPOUTS, PARAPETS,
SOFFITS, OUT BUILDINGS, AWNINGS, LOUVERS, TRIMS, ROOF
MECHANICAL EQUIPMENT AND SUITES, DUCTWORK, HAND/GUARD
RAILS, CAMERA MOUNTS, ROOF HATCHES, STRUCTURAL
SUPPORTS AND COLUMNS
ALL EXTERIOR WALL PENETRATIONS, WINDOWS, SIGNAGE,
EXTERIOR LIGHT FIXTURES, AND FOLIAGE SHALL BE PROPERLY
MASKED AND PROTECTED PRIOR TO PAINTING.
SCREENING SHALL BE USED IN AREAS WHERE THERE IS RISK
FOR CARS TO BE DAMAGED BY OVERSPRAY.
WHERE APPLICABLE, PAINTED ON BUILDING NUMBERS SHALL BE
MASKED AND REPAINTED.
PT-1 PT-1
MASK BUILDING NUMBERS (TYP)
IN PREPARATION FOR PAINTING
PT-1
FV
± 3 0'-
0"
FV
± 3 2'-
0"
PT-1
FV
± 2 6'-
0"
PT-1
FV
± 2 6'-
0"
PT-1
PT-1
VIEW # 1
VIEW #2
VIEW #3VIEW #4
VIEW #5VIEW #5
VIEW #5 VIEW #5
FV
± 18'-0"
FV
± 147'-0"
FV
± 18'-0"
FV± 5
'-0
FV
± 1
'-6
FV± 5
'-0
FV
± 1
'-6
FV
± 183'-0"
A
B
C
D
1 2 3 4 5
A
B
C
D
1 2 3 4 5
SHEET NUMBER
ISSUE DATE
REVISION HISTORY
PROJECT INFORMATION
DRAWN BY:
DESIGNED BY: REVIEWED BY:
PROJECT MANAGER:
PROJECT NUMBER
SHEET TITLE:
GENERAL SHEET NOTES
KEYPLAN
1B
1C
Frankfurt-Short-Bruza Associates, P.C.
5801 Broadway Extension, Suite 500
Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
6" 1'-6"1'0
1 1/2" = 1'-0"
0 6" 1' 2'
1" = 1'-0"
0 1' 2' 4'
1/2" = 1'-0"
0 2' 4' 8'
1/4" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
0 8' 16' 32'
1/16" = 1'-0"
3" 9"6"0
3" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
2' 6'4'0
3/8" = 1'-0"
4' 12'8'0
3/16" = 1'-0"
8' 24'16'0
3/32" = 1'-0"
3A
3B
O K C W ill R og er s In te rn at io na l A irp or t
0 50' 100' 200'
1" = 100'-0"
8/11/2025 4:31:04 PM
C
:\M yR evit\415814-O C
AT_M
M
AC
- PAIN
T H
AN
G
AR
S-A-24_dm onkR
T9D X.rvt
PDC
PDC RLM
HANGAR 3
AUGUST 28, 2025
AE105
M ul ti- H an ga r P ai nt in g
Pr oj ec t N o.
O C A T O K C
O K
LA
H O M A C
IT
Y, O K
LA
H O M A
PU
T YO
U R
C
EN
TR
AL FILE PATH
H
ER
E
CAW
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
FSB2024-158-14
Architectural CoA - 00199 Exp. 06/30/2027
SCALE: NTS
HANGAR 3 - NORTH FACE1
SCALE: NTS
HANGAR 3 - SOUTH FACE2
SCALE: NTS
HANGAR 3 - EAST FACE3
SCALE: NTS
HANGAR 3 - WEST FACE4
SCALE: NTS
HANGAR 3 - FACES AS SEEN FROM ROOF5
SCALE: NTS
N
HANGAR 3 - AERIAL6
FV
± 2 2'-
6"
FV
DESCRIPTION DATE
MARK E.
C.
D.
ALL PREVIOUSLY PAINTED SURFACES SHALL BE PAINTED
INCLUDING BUT NOT LIMITED TO WALLS, DOORS, HIGH BAY
HANGAR DOORS, GUTTERS AND DOWNSPOUTS, PARAPETS,
SOFFITS, OUT BUILDINGS, AWNINGS, LOUVERS, TRIMS, ROOF
MECHANICAL EQUIPMENT AND SUITES, DUCTWORK, HAND/GUARD
RAILS, CAMERA MOUNTS, ROOF HATCHES, STRUCTURAL
SUPPORTS AND COLUMNS
ALL EXTERIOR WALL PENETRATIONS, WINDOWS, SIGNAGE,
EXTERIOR LIGHT FIXTURES, AND FOLIAGE SHALL BE PROPERLY
MASKED AND PROTECTED PRIOR TO PAINTING.
SCREENING SHALL BE USED IN AREAS WHERE THERE IS RISK
FOR CARS TO BE DAMAGED BY OVERSPRAY.
WHERE APPLICABLE, PAINTED ON BUILDING NUMBERS SHALL BE
MASKED AND REPAINTED.
PT-1
FV
± 6 5'-
0"
PT-1
PT-1
FV
± 5 6'-
0"
FV
± 1 3'-
0"
PT-1
PT-1
PT-1
VIEW #1
VIEW #2
VIEW #3
VIEW #4
VIEW #5
VIEW #6
VIEW #7
VIEW #8
VIEW #9
FV
± 2
'-0
FV± 6
4'-
0"
FV
± 64'-0"
FV
± 66'-0"
FV
± 6 8'-
0"
FV
± 157'-0"
A
B
C
D
1 2 3 4 5
A
B
C
D
1 2 3 4 5
SHEET NUMBER
ISSUE DATE
REVISION HISTORY
PROJECT INFORMATION
DRAWN BY:
DESIGNED BY: REVIEWED BY:
PROJECT MANAGER:
PROJECT NUMBER
SHEET TITLE:
GENERAL SHEET NOTES
KEYPLAN
1B
1C
Frankfurt-Short-Bruza Associates, P.C.
5801 Broadway Extension, Suite 500
Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
6" 1'-6"1'0
1 1/2" = 1'-0"
0 6" 1' 2'
1" = 1'-0"
0 1' 2' 4'
1/2" = 1'-0"
0 2' 4' 8'
1/4" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
0 8' 16' 32'
1/16" = 1'-0"
3" 9"6"0
3" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
2' 6'4'0
3/8" = 1'-0"
4' 12'8'0
3/16" = 1'-0"
8' 24'16'0
3/32" = 1'-0"
3A
3B
O K C W ill R og er s In te rn at io na l A irp or t
0 50' 100' 200'
1" = 100'-0"
8/11/2025 4:31:07 PM
C
:\M yR evit\415814-O C
AT_M
M
AC
- PAIN
T H
AN
G
AR
S-A-24_dm onkR
T9D X.rvt
PDC
PDC RLM
HANGAR 3A
AUGUST 28, 2025
AE106
M ul ti- H an ga r P ai nt in g
Pr oj ec t N o.
O C A T O K C
O K
LA
H O M A C
IT
Y, O K
LA
H O M A
PU
T YO
U R
C
EN
TR
AL FILE PATH
H
ER
E
CAW
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
FSB2024-158-14
Architectural CoA - 00199 Exp. 06/30/2027
SCALE: NTS
HANGAR 3A - WEST FACE9
SCALE: NTS
HANGAR 3A - SOUTH FACE3
SCALE: NTS
HANGAR 3A - EAST FACE5
SCALE: NTS
HANGAR 3A - NORTH FACE1 SCALE: NTS
HANGAR 3A - NORTH FACE - ROOF2
SCALE: NTS
HANGAR 3A - SOUTH FACE - ROOF4
SCALE: NTS
HANGAR 3A -
EAST FACE - ROOF7 SCALE: NTS
HANGAR 3A -
EAST FACE - ROOF 28SCALE: NTS
HANGAR 3A - EAST FACE 26
SCALE: NTS
N
HANGAR 3A - AERIAL10
DESCRIPTION DATE
MARK E.
C.
D.
ALL PREVIOUSLY PAINTED SURFACES SHALL BE PAINTED
INCLUDING BUT NOT LIMITED TO WALLS, DOORS, HIGH BAY
HANGAR DOORS, GUTTERS AND DOWNSPOUTS, PARAPETS,
SOFFITS, OUT BUILDINGS, AWNINGS, LOUVERS, TRIMS, ROOF
MECHANICAL EQUIPMENT AND SUITES, DUCTWORK, HAND/GUARD
RAILS, CAMERA MOUNTS, ROOF HATCHES, STRUCTURAL
SUPPORTS AND COLUMNS
ALL EXTERIOR WALL PENETRATIONS, WINDOWS, SIGNAGE,
EXTERIOR LIGHT FIXTURES, AND FOLIAGE SHALL BE PROPERLY
MASKED AND PROTECTED PRIOR TO PAINTING.
SCREENING SHALL BE USED IN AREAS WHERE THERE IS RISK
FOR CARS TO BE DAMAGED BY OVERSPRAY.
WHERE APPLICABLE, PAINTED ON BUILDING NUMBERS SHALL BE
MASKED AND REPAINTED.
PT-1 PT-1
PT-1
PT-1
FV± 2
9'-
0"
FV
± 1 4'-
0"
FV
± 3 0'-
0"
FV
± 4 5'-
0"
PT-1
PT-1
FV
± 1 2'-
0"
VIEW #6
VIEW #6
VIEW #7
VIEW #3
VIEW #4
VIEW #2
VIEW #2
VIEW #1 - SIM
FV
± 3
'-0
FV
± 3 6'-
0"
FV
± 25'-0"
FV
± 130'-0"
VIEW #5
FV
± 3 6'-
0"
PT-1
PORTION OF BUILDING
NO LONGER EXISTS
A
B
C
D
1 2 3 4 5
A
B
C
D
1 2 3 4 5
SHEET NUMBER
ISSUE DATE
REVISION HISTORY
PROJECT INFORMATION
DRAWN BY:
DESIGNED BY: REVIEWED BY:
PROJECT MANAGER:
PROJECT NUMBER
SHEET TITLE:
GENERAL SHEET NOTES
KEYPLAN
1B
1C
Frankfurt-Short-Bruza Associates, P.C.
5801 Broadway Extension, Suite 500
Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
6" 1'-6"1'0
1 1/2" = 1'-0"
0 6" 1' 2'
1" = 1'-0"
0 1' 2' 4'
1/2" = 1'-0"
0 2' 4' 8'
1/4" = 1'-0"
0 4' 8' 16'
1/8" = 1'-0"
0 8' 16' 32'
1/16" = 1'-0"
3" 9"6"0
3" = 1'-0"
1' 3'2'0
3/4" = 1'-0"
2' 6'4'0
3/8" = 1'-0"
4' 12'8'0
3/16" = 1'-0"
8' 24'16'0
3/32" = 1'-0"
3A
3B
O K C W ill R og er s In te rn at io na l A irp or t
0 50' 100' 200'
1" = 100'-0"
8/11/2025 4:31:11 PM
C
:\M yR evit\415814-O C
AT_M
M
AC
- PAIN
T H
AN
G
AR
S-A-24_dm onkR
T9D X.rvt
PDC
PDC RLM
HANGAR 3B
AUGUST 28, 2025
AE107
M ul ti- H an ga r P ai nt in g
Pr oj ec t N o.
O C A T O K C
O K
LA
H O M A C
IT
Y, O K
LA
H O M A
PU
T YO
U R
C
EN
TR
AL FILE PATH
H
ER
E
CAW
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
FSB2024-158-14
Architectural CoA - 00199 Exp. 06/30/2027
SCALE: NTS
HANGAR 3B - SOUTH AND WEST FACES6 SCALE: NTS
HANGAR 3B - WEST FACE7
SCALE: NTS
HANGAR 3B - SOUTH &
EAST FACES2
SCALE: NTS
HANGAR 3B - NORTH FACE1
SCALE: NTS
HANGAR 3B - EAST FACE4
SCALE: NTS
HANGAR 3B - SOUTH FACE - ROOF3
SCALE: NTS
N
HANGAR 3B - AERIAL8SCALE: NTS
HANGAR 3B - NORTH & EAST FACES5
DESCRIPTION DATE
MARK E.
| GENERAL |
| G-001 - COVER SHEET |
| ARCHITECTURE |
| A-001 - ABBREVIATIONS AND SYMBOLS |
| AS100 - ARCHITECTURAL SITE PLAN |
| AE101 - HANGAR 1C |
| AE102 - HANGAR 1B |
| AE103 - HANGAR 1 |
| AE104 - HANGAR 2 |
| AE105 - HANGAR 3 |
| AE106 - HANGAR 3A |
| AE107 - HANGAR 3B |
File details come from the government source that posted it. Updated .