2024.09.03_ANL_SSA_Prepurchase_DWGS_R3.pdf.pdf
PDF 7 MB Posted
- Attached to
- Building 420 Sector 36 Solid State Amplifiers
- Solicitation number
- 4-B176-Q-00735-00
- Issued by
-
Department of Energy Office of Science
About this file
This document is a Request for Quotation (RFQ) issued by UChicago Argonne, LLC for the procurement of electrical equipment, including a transformer, switchboards, and panelboards, as part of the proposed Building 420 Sector 36 Solid State Amplifiers project. The equipment will be ordered under this RFQ but installed and commissioned by an electrical contractor under a future construction contract. The RFQ is based on the lowest price technically acceptable criteria, and responses are due by September 18th. The key equipment required includes a 2000/2666 kVA dry type medium voltage transformer, a 3000A 480Y/277V 3-phase 4-wire switchboard, and four 600A 480V 3-phase 4-wire power distribution panelboards. The Department of Energy Office of Science is the federal agency involved in this procurement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 26 2416-Panelboards REV 2.pdf | ||
| Addendum and Acknowledgement Doc.doc | DOC document | |
| ANL-70 Request for Quotation.doc | DOC document | |
| Enclosure No.1 Instructions to Offerors_4-B176-Q-00735-00.doc | DOC document | |
| Appendix D8C-12-DEC-2023.PDF | ||
| Property Questionnaire-08-SEP-2023.PDF | ||
| Special Cl-Progress Pmts-02-SEP-2015.PDF | ||
| Appendix A-71COM-13-FEB-2023.PDF | ||
| LPTA Form.docx.docx | DOCX document | |
| Reps and Certs ANL-70B.doc | DOC document | |
| 2024.09.03_ANL_SSA_Prepurchase_SPECS.pdf.pdf | ||
| Electrical Equipment Pre-Purchase SOW 9-03-24.docx.docx | DOCX document | |
| Property Requirements-31-AUG-2023.PDF |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COOLING TOWERS
RESERVED
PARKING
ELECTRIC
VEHICLE
CHARGING
ONLY
RESERVED
PARKING
ELECTRIC
VEHICLE
CHARGING
ONLY
RESERVED
PARKING
ELECTRIC
VEHICLE
CHARGING
ONLY
RESERVED
PARKING
ELECTRIC
VEHICLE
CHARGING
ONLY
VISITOR
VISITOR
VISITOR
RESERVED
RESERVED
RESERVED
WARNING
IF PLAN IS ENLARGED OR REDUCED,
GRAPHIC SCALE SHALL BE USED.
J420-104-W- G001 0
BUILDING 420
SOLID STATE AMPLIFIER
TITLE SHEET
AND DRAWING INDEX
Grumman/Butkus Associates Energy Efficiency Consultants and Sustainable Design Engineers
820 Davis St, Ste 300 Evanston, Illinois 60201 4446 847 328.3555 www.grummanbutkus.com Copyright © 2023 Grumman/Butkus Associates Illinois Registration #184-000926 GBA Project: P23-0858-00
1" = 750FT1 SITE PLAN
SEE ENLARGED
LOCATION MAP
1"= 200FT2 ENLARGED VIEW
ARGONNE NATIONAL LABORATORY
BUILDING 420 SOLID STATE AMPLIFIER
PHASE 1 - OWNER EQUIPMENT PRE-PURCHASE
ARGONNE NATIONAL LABORATORY
9700 SOUTH CASS AVENUE
ARGONNE, ILLINOIS 60439
PROJECT MANAGER: LIZ OTT
GENERAL NOTES:
1. ALL WORK DONE BY CONTRACTOR/INSTALLER PURSUANT TO THIS DRAWING
SHALL:
(A) CONFORM TO THE GOVERNING CONTRACT DOCUMENTS.
(B) BE PERFORMED EXCLUSIVELY BY ITS TRAINED, COMPETENT PERSONNEL
OR, WHERE PERMITTED, THAT OF ITS SUBCONTRACTOR(S).
(C) COMPLY WITH ALL APPLICABLE SAFETY LAWS, REGULATIONS, PROGRAMS
AND PRACTICES TO ENSURE THE SAFETY OF ALL PEOPLE LOCATED ON
THE WORK SITE, INCLUDING THE CONTRACTOR'S / INSTALLER'S
PERSONNEL ( OR THAT OF ITS SUBCONTRACTOR(S) ) PERFORMING THE
WORK.
2. UNDERGROUND OR EMBEDDED UTILITIES [MAY] EXIST WITHIN THE AREA OF
AND ADJACENT TO THE LIMITS OF THE WORK. THE LOCATION OR
IDENTIFICATION OF SUCH UTILITIES HAS NOT BEEN VERIFIED BY OWNER.
CONTRACTOR/INSTALLER IS RESPONSIBLE FOR FIELD LOCATING AND
IDENTIFYING UNDERGROUND AND EMBEDDED UTILITIES AND ANY OTHER
UNDERGROUND AND EMBEDDED UTILITY DIMENSIONS.
3. REFERENCES USED HAVE BEEN IDENTIFIED ON EXCAVATION / FOUNDATION /
DEMOLITION DRAWINGS AND HAVE BEEN PROVIDED TO ASSIST THE
CONTRACTOR / INSTALLER IN THE FIELD LOCATING EXISTING UTILITIES AND
OTHER POTENTIAL UNDERGROUND OR EMBEDDED INTERFERENCES. THESE
REFERENCES ONLY SHOW THE APPROXIMATE LOCATION OF POTENTIAL
UNDERGROUND OR EMBEDDED UTILITIES AND MAY NOT INDICATE OR REFLECT
ALL EXISTING UNDERGROUND OR EMBEDDED UTILITIES OR THEIR ACTUAL
LOCATIONS.
4. REFERENCES IDENTIFIED SHALL NOT SUBSTITUTE FOR THE CONTRACTOR'S /
INSTALLER'S OBLIGATION TO FIELD LOCATE ANY UNDERGROUND OR EMBEDDED
UTILITIES OR INTERFERENCES THAT MAY AFFECT THE WORK.
5. DUE CAUTION SHALL BE TAKEN DURING ANY EXCAVATION / FOUNDATION /
DEMOLITION WORK WITHIN THE AREA OF AND ADJACENT TO THE LIMITS OF
THE WORK DUE TO POSSIBLE INTERFERENCES THAT MAY NOT BE REFLECTED
ON THE REFERENCES IDENTIFIED.
6. HORIZONTAL DATUM: NAD83 STATE PLANE ILLINOIS EAST. VERTICAL DATUM:
NAVD88 VERTICAL. UNITS: US SURVEY FOOT.
DRAWING INDEX
GENERAL DRAWING TITLE
J420-G-W-G001 TITLE SHEET & DRAWING INDEX
ELECTRICAL
J420-104-W-E001 ELECTRICAL SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES
J420-104-W-E100 ELECTRICAL BUILDING EXTERIOR NEW WORK
J420-104-W-E101N ELECTRICAL FIRST FLOOR S36 NORTH NEW WORK
J420-104-W-E101S ELECTRICAL FIRST FLOOR S36 SOUTH NEW WORK
J420-104-W-E401 ELECTRICAL SINGLE LINE DIAGRAMS
J420-104-W-E500 ELECTRICAL PANEL SCHEDULES
J420-104-W-E601 ELECTRICAL DETAILS
1. IN THIS PHASE OF WORK, THE MATERIAL VENDORS SHALL PROVIDE THE FOLLOWING MATERIALS ONLY AS PRESCRIBED BY THE ARGONNE NATIONAL LAB SCOPE OF WORK DOCUMENT FOR THIS PREPURCHASE.
GENERAL SCOPE OF WORK IN THIS CONTRACT (PREPURCHASE)
G001.1
FO
R
PR
EP
UR
CH
AS
E
ON
LY
NO
T
FO
R
CO
NS
TR
UC
TI
ON
AutoCAD SHX Text
EXTENSION
AutoCAD SHX Text
LANDFILL
AutoCAD SHX Text
ENE
AutoCAD SHX Text
AREA
AutoCAD SHX Text
AutoCAD SHX Text 330J
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text 046A
AutoCAD SHX Text
MONUMENT MISSING
AutoCAD SHX Text
ANL GRID BASE
AutoCAD SHX Text
AutoCAD SHX Text
TRAILERS
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
AutoCAD SHX Text 391A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CENTRAL DRIVE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 597A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NORTHGATE ROAD
AutoCAD SHX Text
WESTGATE ROAD
AutoCAD SHX Text
FRONT STREET
AutoCAD SHX Text
FRONT STREET
AutoCAD SHX Text
NORTHGATE ROAD
AutoCAD SHX Text 94th STREET
AutoCAD SHX Text
AutoCAD SHX Text
PONDS
AutoCAD SHX Text
FREUND
AutoCAD SHX Text
SAINT
AutoCAD SHX Text
A.T. & S.F. R.R. SPUR R. O. W.
AutoCAD SHX Text
A N L BOUNDARY LINE
AutoCAD SHX Text
A N L BOUNDARY LINE
AutoCAD SHX Text
A N L BOUNDARY LINE
AutoCAD SHX Text
A N L BOUNDARY LINE
AutoCAD SHX Text
A N L BOUNDARY LINE
AutoCAD SHX Text
A N L BOUNDARY LINE
AutoCAD SHX Text
A N L BOUNDARY LINE
AutoCAD SHX Text
ARGONNE
AutoCAD SHX Text 035B
AutoCAD SHX Text
AREA
AutoCAD SHX Text
LAND FILL
AutoCAD SHX Text
LEMONT ROAD
AutoCAD SHX Text
YARD
AutoCAD SHX Text
COAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 108A
AutoCAD SHX Text 108B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 94th STREET
AutoCAD SHX Text
AutoCAD SHX Text 891A
AutoCAD SHX Text
MADDEN ROAD
AutoCAD SHX Text
NATURE PRESERVE
AutoCAD SHX Text
WATERFALL GLEN
AutoCAD SHX Text
NATURE PRESERVE
AutoCAD SHX Text
WATERFALL GLEN
AutoCAD SHX Text
NORTHERN ILLINOIS GAS CO. EASEMENT (36" PIPE IN 42" CASING)
AutoCAD SHX Text
RAILROAD DRIVE
AutoCAD SHX Text
AutoCAD SHX Text 484A
AutoCAD SHX Text
AutoCAD SHX Text
CEMETERY
AutoCAD SHX Text
PATRICK'S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NATURE PRESERVE
AutoCAD SHX Text
WATERFALL GLEN
AutoCAD SHX Text
NORTHERN ILLINOIS GAS CO. EASEMENT (36" PIPE IN 42" CASING)
AutoCAD SHX Text
CASS AVENUE
AutoCAD SHX Text
OLD BLUFF ROAD
AutoCAD SHX Text
AutoCAD SHX Text
NATURE PRESERVE
AutoCAD SHX Text
WATERFALL GLEN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 389B
AutoCAD SHX Text
BLUFF ROAD
AutoCAD SHX Text
NORTHERN ILLINOIS GAS CO. EASEMENT (36" PIPE IN 42" CASING)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PARK
AutoCAD SHX Text
AVENUE
AutoCAD SHX Text
MERIDIAN ROAD
AutoCAD SHX Text
BLUFF ROAD
AutoCAD SHX Text
SOUTHWOOD DRIVE
AutoCAD SHX Text
MERIDIAN ROAD
AutoCAD SHX Text
KEARNEY ROAD
AutoCAD SHX Text
WATERTOWER ROAD
AutoCAD SHX Text
INNER CIRCLE
AutoCAD SHX Text
OUTER CIRCLE ROAD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
COMPLEX
AutoCAD SHX Text 401,402
AutoCAD SHX Text
COMPLEX
AutoCAD SHX Text 314,315&316
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 544B
AutoCAD SHX Text 544A
AutoCAD SHX Text
EASTWOOD
AutoCAD SHX Text
AutoCAD SHX Text 531A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BLUFF ROAD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TECH ROAD
AutoCAD SHX Text
AutoCAD SHX Text
EASTWOOD DRIVE
AutoCAD SHX Text
RAILROAD DRIVE
AutoCAD SHX Text
EASTWOOD EXTENSION
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
FREUND
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ROCK ROAD
AutoCAD SHX Text 549A
AutoCAD SHX Text
AREA
AutoCAD SHX Text
STAGING
AutoCAD SHX Text C
AutoCAD SHX Text
OLD BLUFF ROAD
AutoCAD SHX Text
AutoCAD SHX Text 366A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 363A
AutoCAD SHX Text 363B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 375D
AutoCAD SHX Text
AutoCAD SHX Text 375A
AutoCAD SHX Text
AutoCAD SHX Text 391B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 331A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 206A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RAMP
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
GRASS
AutoCAD SHX Text
5' WALK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AREA
AutoCAD SHX Text
TRANSFORMER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TX-1
AutoCAD SHX Text
TX-2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AREA
AutoCAD SHX Text
CLAY STORAGE
AutoCAD SHX Text
TOP SOIL STORAGE
AutoCAD SHX Text
AREA
AutoCAD SHX Text
CONCRETE ASPHALT RECYCLING
AutoCAD SHX Text
AREA
AutoCAD SHX Text
ELECTRICAL STORAGE
AutoCAD SHX Text
AREA
AutoCAD SHX Text
T130-TR1
AutoCAD SHX Text
AutoCAD SHX Text 400A
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text
RIGGERS
AutoCAD SHX Text
PAD
AutoCAD SHX Text
WETLAND
AutoCAD SHX Text
TOP SOIL STORAGE
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
LOCKED
AutoCAD SHX Text x
AutoCAD SHX Text
DUMPSTER
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text x
AutoCAD SHX Text
US EPA & DOE
AutoCAD SHX Text
TRAILERS
AutoCAD SHX Text
WETLAND
AutoCAD SHX Text
BERM AREA
AutoCAD SHX Text
BERM AREA
AutoCAD SHX Text
T-800-TR10
AutoCAD SHX Text
AutoCAD SHX Text
TR 8
AutoCAD SHX Text
TR 9
AutoCAD SHX Text T-800
AutoCAD SHX Text
TR10
AutoCAD SHX Text
TR11
AutoCAD SHX Text
AutoCAD SHX Text
SHED
AutoCAD SHX Text
WEIGH STATION
AutoCAD SHX Text 541A
AutoCAD SHX Text
T333-TR1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WETLAND
AutoCAD SHX Text
ROCK ROAD
AutoCAD SHX Text
NORTHERN ILLINOIS GAS CO. EASEMENT
AutoCAD SHX Text
NORTHERN ILLINOIS GAS CO. EASEMENT
AutoCAD SHX Text
NORTHERN ILLINOIS GAS CO. EASEMENT
AutoCAD SHX Text
NORTHERN ILLINOIS GAS CO. EASEMENT
AutoCAD SHX Text
NORTHERN ILLINOIS GAS CO. EASEMENT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A/B
AutoCAD SHX Text G
AutoCAD SHX Text
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
COOLING
AutoCAD SHX Text
TOWER
AutoCAD SHX Text 318B
AutoCAD SHX Text
BLUFF ROAD
AutoCAD SHX Text
AutoCAD SHX Text
ANTENNAE
AutoCAD SHX Text
TOWER
AutoCAD SHX Text
ANTENNAE
AutoCAD SHX Text
TOWER
AutoCAD SHX Text
ANTENNAE
AutoCAD SHX Text
TOWER
AutoCAD SHX Text 042B
AutoCAD SHX Text 042A
AutoCAD SHX Text 541B
AutoCAD SHX Text
DIESEL GENERATOR
AutoCAD SHX Text
500KW
AutoCAD SHX Text 541C
AutoCAD SHX Text
T390 TR1
AutoCAD SHX Text
T390 TR2
AutoCAD SHX Text
WIND TURBINE
AutoCAD SHX Text
SOLAR ARRAY
AutoCAD SHX Text
H2 TRAILER T-205-TR1
AutoCAD SHX Text
COOLING TOWER
AutoCAD SHX Text
CO STORAGE
AutoCAD SHX Text
H2 STORAGE
AutoCAD SHX Text
CO2 STORAGE
AutoCAD SHX Text
N2 STORAGE
AutoCAD SHX Text
C3H8 STORAGE
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
T378-TR
AutoCAD SHX Text
T378-TR
AutoCAD SHX Text
T378-TR
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text
TRAILER
AutoCAD SHX Text 13.2kv
AutoCAD SHX Text
ATS
AutoCAD SHX Text
TR-2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
T-800-TR17
AutoCAD SHX Text
T-800-TR18
AutoCAD SHX Text T12
AutoCAD SHX Text H3
AutoCAD SHX Text H2
AutoCAD SHX Text H1
AutoCAD SHX Text X0
AutoCAD SHX Text T-1
AutoCAD SHX Text T12
AutoCAD SHX Text H3
AutoCAD SHX Text H2
AutoCAD SHX Text H1
AutoCAD SHX Text X0
AutoCAD SHX Text T-2
AutoCAD SHX Text
GCB 152
AutoCAD SHX Text
LINE A3
AutoCAD SHX Text
LINE A4
AutoCAD SHX Text
GCB 252
AutoCAD SHX Text
SWGR. BLDG.
AutoCAD SHX Text H3
AutoCAD SHX Text H2
AutoCAD SHX Text H1
AutoCAD SHX Text X0
AutoCAD SHX Text T12
AutoCAD SHX Text Y9
AutoCAD SHX Text Y8
AutoCAD SHX Text Z9
AutoCAD SHX Text Z8
AutoCAD SHX Text
20'-0" DRIVE GATE (TYP.)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TX-1
AutoCAD SHX Text
TX-2
AutoCAD SHX Text 400A
AutoCAD SHX Text
AutoCAD SHX Text
BLUFF ROAD
AutoCAD SHX Text
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
FACILITY DOCUMENT NO.
AutoCAD SHX Text
CADD NUMBER
AutoCAD SHX Text
FACILITY NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
APVD
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
J420-104-W-G001.DWG
AutoCAD SHX Text B420
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text
JET
AutoCAD SHX Text A
AutoCAD SHX Text
PRE-PURCHASE REVIEW
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text 06-10-24
AutoCAD SHX Text B
AutoCAD SHX Text
ISSUED FOR PREPURCHASE
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text 09-03-24
AutoCAD SHX Text N
AutoCAD SHX Text N
WARNING
IF PLAN IS ENLARGED OR REDUCED,
GRAPHIC SCALE SHALL BE USED.
J420-104-W- E001 0
BUILDING 420
SOLID STATE AMPLIFIER
ELECTRICAL SYMBOLS,
ABBREVIATIONS,
AND GENERAL NOTES
Grumman/Butkus Associates Energy Efficiency Consultants and Sustainable Design Engineers
820 Davis St, Ste 300 Evanston, Illinois 60201 4446 847 328.3555 www.grummanbutkus.com Copyright © 2023 Grumman/Butkus Associates Illinois Registration #184-000926 GBA Project: P23-0858-00
DESCRIPTIONDESIGNATION
EXISTING
NEW WORK
DESCRIPTIONSYMBOL
ER EXISTING ELECTRICAL EQUIPMENT OR OUTLET TO REMAIN
EXISTING ELECTRICAL EQUIPMENT OR OUTLET TO BE REMOVED
RELOCATED AND JUNCTION BOX REMOVED OR CAPPED AS REQUIRED.RL
NL EXISTING ELECTRICAL EQUIPMENT OR OUTLET RELOCATED (NEW
LOCATION)
RE EXISTING ELECTRICAL EQUIPMENT OR OUTLET TO BE REMOVED
EC EXISTING ELECTRICAL EQUIPMENT OR OUTLET TO BE REMOVED AND
JUNCTION BOX CAPPED AS REQUIRED
NR NEW ELECTRICAL EQUIPMENT INSTALLED OVER EXISTING OUTLET
EA EXISTING ELECTRICAL EQUIPMENT OR OUTLET TO BE ABANDONED
EM EXISTING ELECTRICAL EQUIPMENT OR OUTLET TO BE MODIFIED
AC ALTERNATING CURRENT
AF AMPERE FRAME, AMPERE FUSE
AFF ABOVE FINISHED FLOOR
AM AMP METER
AMP AMPERE
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRING GUAGE
BP BRANCH CIRCUIT PANEL
BKR BREAKER
C CONDUIT
CATV CABLE ACCESSED TELEVISION
C/B CIRCUIT BREAKER
CKT CIRCUIT
CT CURRENT TRANSFORMER
CU COPPER
DC DIRECT CURRENT
DISC DISCONNECT
DN DOWN
DWG DRAWING
EM EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRIC METALLIC TUBING
EPO EMERGENCY POWER OFF
E EXISTING
F FUSE
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FLA FULL LOAD AMPERES
FLR FLOOR
FMC FLEXIBLE METAL CONDUIT
GEN GENERATOR
GF GROUND FAULT
GFCI GROUND FAULT CIRCUIT INTERRUPTER
G GROUND
HID HIGH INTENSITY DISCHARGE
HOA HAND OFF AUTO
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HZ HERTZ (CYCLE)
IC INTERRUPTING CAPACITY
IEEE INSTITUTE OF ELECTRICAL AND
ELECTRONICS ENGINEERS
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
JB JUNCTION BOX
KV KILOVOLT
KVA KILOVOLT-AMPERE
KW KILOWATT
LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT
LPS LOW PRESSURE SODIUM
LP LIGHTING PANEL
LRA LOCKED ROTOR AMPERES
LRP LIGHTING RELAY PANEL
LTG LIGHTING
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MLO MAIN LUGS ONLY
MIN MINIMUM
N/A NOT APPLICABLE
NATS NON-AUTOMATIC TRANSFER SWITCH
NC NORMALLY CLOSED
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NETA NATIONAL ELECTRICAL TESTING
ASSOCIATION
NF NON-FUSED
NO NORMALLY OPEN
OC OVER CURRENT
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
P POLE
PB PULL BOX
PDU POWER DISTRIBUTION UNIT
PE PROFESSIONAL ENGINEER
PF POWER FACTOR
PH PHASE
PM POWER MONITORING DEVICE
PNL PANELBOARD
PP POWER PANEL
PT POTENTIAL TRANSFORMER
PVC POLYVINYL CHLORIDE
RFI RADIO FREQUENCY INTERFERENCE
RGS RIGID GALVANIZED STEEL CONDUIT
RMC RIGID METAL CONDUIT
RMS ROOT MEAN SQUARE
RP RECEPTACLE PANEL
SCA SHORT CIRCUIT AMPERES
SW SWITCH
SWBD SWITCHBOARD
T TELEPHONE
THD TOTAL HARMONIC DISTORTION
TIA TELECOMMUNICATIONS INDUSTRY
ASSOCIATION
TV TELEVISION
TVSS TRANSIENT VOLTAGE SURGE
SUPPRESSION
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLTAGE
VA VOLT-AMPERE
VFD VARIABLE FREQUENCY DRIVE
VM VOLT METER
W WATT
WP WEATHERPROOF
WM WATT METER
XFMR TRANSFORMER
DESCRIPTIONDESIGNATION
AMMETERA
AUTOMATIC TRANSFER SWITCHN
L
E
BATTERY
BRANCH CIRCUIT PANELBOARD
XX
XX
CONTACT - NORMALLY CLOSEDNC
NORMALLY OPENED CONTACTNO
GROUND FAULT PROTECTIVE DEVICEGF
GROUND
POWER METERPM
SURGE PROTECTION DEVICE (TVSS)
X=A,B,C
SPD
X
THERMAL OVERLOAD
CURRENT TRANSFORMER
CT
POTENTIAL TRANSFORMER
PT
VOLTMETERV
PROTECTIVE RELAY
X=PROTECTIVE DEVICE NUMBER
EX. 59=OVERVOLTAGE
X
SWITCH
X=SWITCH AMPEREX
FUSED SWITCH
X=SWITCH AMPERE
Y=FUSE AMPERE OR TYPEY
X
FUSE
Y=FUSE AMPERE OR TYPEY
CIRCUIT BREAKER - MOLDED CASE
X=AMPERE FRAME (AF)
Y=AMPERE TRIP (AT)Y
X
CIRCUIT BREAKER - DRAWOUT
X=AMPERE FRAME (AF)
Y=AMPERE TRIP (AT)
X Y
GENERATORG
TRANSFORMER
X=KVA RATING
Y=PRIMARY VOLTAGE
Z=SECONDARY VOLTAGE (E.G. 208Y/120V)
Z
X Y T
DESCRIPTIONDESIGNATION
DUPLEX RECEPTACLE (WALL MOUNTED)
+18" AFF UNO
DUPLEX RECEPTACLE (WALL MOUNTED)
ABOVE COUNTER HEIGHT
DOUBLE DUPLEX (WALL MOUNTED)
+18" AFF UNO
GROUND FAULT INTERRUPTER DUPLEX RECEPTACLE (WALL
MOUNTED)
+18" AFF UNO
GFI
SINGLE SPECIAL OUTLET - SEE PLANS FOR NEMA
CONFIGURATION
DISCONNECT SWITCH (NON-FUSED)
FUSED DISCONNECT SWITCHF
BREAKER DISCONNECTB
EQUIPMENT TAG
SEE EQUIPMENT SCHEDULEY
X
HANDHOLEHH
TRANSFORMER
T=KVAT
VARIABLE FREQUENCY DRIVEVFD
EMERGENCY POWER OFF STATION.
"K" INDICATES KEYED OPERATIONK
EPO
BRANCH CIRCUIT PANELBOARDLP-X
POWER DISTRIBUTION PANELBOARDDP-X
CEILING MOUNTED JUNCTION BOXJ
WALL MOUNTED JUNCTION BOXJ
COMBINATION MOTOR STARTER AND DISCONNECT SWITCH
1. CODES
THE WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, MUNICIPAL, AND NATIONAL
CODES. WHERE THE CONSTRUCTION DOCUMENTS INDICATE MORE RESTRICTIVE
REQUIREMENTS THE CONSTRUCTION DOCUMENTS SHALL GOVERN. HOWEVER, THE
CONSTRUCTION DOCUMENTS SHALL NOT BE INTERPRETED AS AUTHORITY TO VIOLATE
ANY CODE OR REGULATION.
2. DRAWINGS AND SPECIFICATIONS
THE CONTRACTOR SHALL BE RESPONSIBLE FOR READING AND COMPLYING WITH BOTH
THE DRAWINGS AND SPECIFICATIONS. IN THE EVENT OF A CONFLICT OR
INCONSISTENCY BETWEEN THE DRAWINGS, NOTES, SPECIFICATIONS, OR CODES, THE
REFERENCE WHICH PROVIDES THE MORE COMPLETE OR HIGHER STANDARD SHALL
PREVAIL.
3. INTERPRETATION OF THE DOCUMENTS
CAREFULLY COMPARE THE DRAWINGS AND SPECIFICATIONS, CHECKING
MEASUREMENTS AND CONDITIONS UNDER WHICH THIS INSTALLATION IS TO BE MADE.
FOR CLARIFICATION BETWEEN VARIOUS DRAWINGS, BETWEEN DRAWINGS OR
SPECIFICATION, OR BETWEEN SECTIONS OF THE SPECIFICATION, THE MATTER SHALL BE
REFERRED TO THE ENGINEER BEFORE ANY WORK IS EXECUTED. THE CONTRACTOR
SHALL STATE IN THEIR PROPOSAL ANY EXCEPTIONS NECESSARY TO MAKE THIS A
COMPLETE, READY TO USE INSTALLATION. IF NOT STATED IN THE PROPOSAL, IT WILL
NOT BE CONSIDERED EXTRA.
4. ELECTRICAL DRAWINGS
THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. THE
CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL DOORS, WALLS,
FURNITURE, EQUIPMENT, ETC. THE LOCATION OF RACEWAY SYSTEM COMPONENTS IS
SCHEMATIC. THE EXACT LOCATION OF RACEWAY SYSTEM COMPONENTS SHALL BE
DETERMINED BY THE CONTRACTOR IN THE FIELD. THE CONTRACTOR SHALL CONFIRM
THE DIMENSIONS OF THE ACTUAL EQUIPMENT TO BE SUPPLIED FOR THIS PROJECT, AND
VERIFY CLEARANCES AND ROUGH-INS PRIOR TO STARTING WORK.
5. SITE EXAMINATION
BEFORE SUBMITTING A BID, THE CONTRACTOR SHALL VISIT THE SITE, EXAMINE THE
PREMISES, AND MAKE A THOROUGH SURVEY OF THE EXISTING CONDITIONS. THE
SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN
EXAMINATION HAS BEEN MADE. NO CONSIDERATION OR ALLOWANCE WILL BE GRANTED
FOR FAILURE TO VISIT THE SITE OR FOR LATER CLAIMS FOR LABOR, EQUIPMENT,
MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN
FORESEEN HAD SUCH AN SITE EXAMINATION BEEN MADE.
6. COORDINATION WITH OTHER TRADES
THE ELECTRICAL CONTRACTOR SHALL OBTAIN A COMPLETE SET OF ARCHITECTURAL
AND ENGINEERING DOCUMENTS AND COORDINATE WITH MECHANICAL, PLUMBING,
ARCHITECTURAL, AND OTHER TRADES FOR EXACT DIMENSIONS, CLEARANCES,
ROUGH-IN LOCATIONS, AND OTHER ADDITIONAL SCOPES OF WORK THAT MAY NOT BE
SHOWN ON THE ELECTRICAL PLANS. THE ELECTRICAL CONTRACTOR SHALL BE
RESPONSIBLE FOR ALL 120 VOLT (AND HIGHER) AC POWER TO OTHER TRADES
EQUIPMENT AND HARDWARE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO, CONTROLS,
FIRE AND SECURITY SYSTEMS, MOTORIZED DOORS, DAMPERS, LIFTS, AND OTHER
SYSTEMS. UNLESS SPECIFICALLY NOTED OTHERWISE ON THE ELECTRICAL PLANS, THE
ELECTRICAL CONTRACTOR SHALL FURNISH ALL SAFETY DISCONNECT SWITCHES TO
MECHANICAL EQUIPMENT.
7. PERMITS, APPLICATIONS AND RELEASES
THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS INSPECTIONS,
APPLICATIONS, RELEASES AND FEES REQUIRED BY LOCAL, STATE AND FEDERAL
AGENCIES FOR THE EXECUTION OF THIS WORK. SCHEDULING OF ALL REQUIRED
INSPECTIONS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
8. FIRE STOPPING
ALL PENETRATIONS IN WALL, FLOOR OR CEILINGS SHALL BE SUITABLY CLOSED UP AND
SEALED WITH AN INTUMESCENT FIRE STOPPING COMPOUND LISTED IN THE MOST
RECENT FACTORY MUTUAL RESEARCH CORPORATION (FMRC) APPROVAL GUIDE. FIRE
STOPPING PRODUCTS SHALL BE MANUFACTURED BY 3M COMPANY OR APPROVED
EQUAL.
9. PAINTING
ALL NEWLY INSTALLED EXPOSED PIPING SHALL BE PAINTED TO MATCH THE EXISTING
ADJACENT WALL OR CEILING SURFACE.
10. OWNER FURNISHED EQUIPMENT
EQUIPMENT THAT WILL BE FURNISHED BY THE OWNER WILL BE INDICATED ON A
SEPARATE SPECIFIED SCHEDULE. THE CONTRACTOR SHALL COORDINATE WITH THE
OWNER FOR DELIVERY SCHEDULES. THE CONTRACTOR IS TO ASSUME THAT ON SITE
STORAGE MAY NOT BE AVAILABLE WHEN COORDINATING DELIVERY OF EQUIPMENT. THE
CONTRACTOR, IN COORDINATION WITH THE OWNER'S REPRESENTATIVE, WILL INSPECT
THE DELIVERY FOR ACCURACY AND SHIPMENT DAMAGE AND ACCEPTING THE
EQUIPMENT. THE CONTRACTOR SHALL BE RESPONSIBLE TO STORE, PROTECT AND
ULTIMATELY INSTALL THE EQUIPMENT.
11. ELECTRICAL SERVICE DISRUPTIONS
ALL WORK WHICH EXPOSES ACTIVE BUS REQUIRES A WRITTEN NOTIFICATION TO THE
OWNER WHICH WILL OUTLINE THE METHOD OF PROCEDURE FOR THE WORK. THE
CONTRACTOR SHALL PROVIDE A MINIMUM OF 5 DAYS NOTICE TO THE OWNER BEFORE
WORKING ON ANY ENERGIZED ELECTRICAL SYSTEM. ALL POWER DISRUPTION SHALL
OCCUR AT TIMES AND OF DURATIONS ACCEPTABLE TO THE OWNER.
12. EQUIPMENT
ALL MATERIALS AND EQUIPMENT USED IN THIS INSTALLATION SHALL BE NEW, AND HAVE
THE APPROPRIATE UL LISTING AND LABEL.
13. MISCELLANEOUS SUPPORTING MEMBERS
ALL ANGLES CHANNELS, AND OTHER MISCELLANEOUS STEEL, BOLTS, RODS, ETC.
REQUIRED TO SUPPORT LIGHT FIXTURE, CONDUIT, RACEWAY, LADDER TRAY, OR OTHER
ELECTRICAL EQUIPMENT OR DEVICES SHALL BE FURNISHED AND INSTALLED BY THE
CONTRACTOR.
14. PANELBOARDS
ALL PANELBOARDS SHALL BE PROVIDED WITH TYPEWRITTEN DIRECTORIES. SEE PANEL
SCHEDULES ON THE DRAWINGS AND SPECIFICATIONS FOR COMPLETE IDENTIFICATION
AND LABELING REQUIREMENTS.
15. SAFETY
THE CONTRACTOR SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE SAFETY OF
THE OWNERS EMPLOYEES, BUILDING EMPLOYEES AND GUESTS, AS WELL AS THEIR OWN
FORCES, BY ADEQUATELY PROTECTING ANY EXPOSED LIVE CONDUCTORS, OR DEVICES
THROUGHOUT THE COURSE OF THIS WORK.
COMPLY WITH NFPA 241 FOR SAFEGUARDING DURING CONSTRUCTION AND ALTERATION
OPERATIONS. IN ADDITION, ANY OPENINGS IN FIRE RATED SEPARATIONS BETWEEN
OCCUPIED AND UNOCCUPIED (OR OPERATIONAL AND NON-OPERATIONAL) AREAS SHALL
BE SEALED AT THE END OF EACH WORK DAY WITH AN APPROPRIATE FIRE RATED
ENCLOSURE OR SEALANT. DO NOT COMPROMISE EXISTING SECURITY OR FIRE ALARM
SYSTEMS SERVING THE OCCUPIED OR OPERATIONAL AREAS.
16. EQUIPMENT CONNECTIONS
PROVIDE FINAL ELECTRICAL CONNECTIONS TO ALL EQUIPMENT FURNISHED UNDER
OTHER TRADES AND FOR ALL OWNER FURNISHED EQUIPMENT. PROVIDE A FLEXIBLE
LIQUID TIGHT CONNECTION TO ALL VIBRATION PRODUCING EQUIPMENT.
17. INTERFERENCE WITH OCCUPANCY
THE PRESENT BUILDING IS OCCUPIED AND WILL CONTINUE TO BE DURING THE
PROGRESS OF THIS WORK. IT IS IMPERATIVE, THEREFORE, THAT THE WORK COVERED
BY THESE DOCUMENTS BE EXECUTED WITH A MINIMUM OF INCONVENIENCE TO THE
BUILDING PERSONNEL, AND OTHER TENANTS.
18. TEMPORARY REQUIREMENTS
PROVIDE TEMPORARY LIGHTING, POWER, AND FIRE ALARM COMPONENTS AS REQUIRED
IN AREAS UNDERGOING WORK DURING CONSTRUCTION.
FURNISH AND INSTALL ONE OSHA APPROVED PIGTAIL SOCKET WITH 150-WATT LAMP
FOR EVERY 500 SQUARE FEET OF FLOOR SPACE AND A MINIMUM 1 PER ROOM. THE
TEMPORARY LIGHTING SHALL BE LEFT IN PLACE UNTIL PERMANENT LIGHTING IS
COMPLETELY OPERATIONAL.
FURNISH AND INSTALL POWER OUTLETS TO A TOTAL ONE FOR EVERY 2000 SQUARE
FEET OR PART THEREOF OF FLOOR AREA AND THESE SHALL BE 15 AMP, SINGLE PHASE
RECEPTACLES FOR EITHER 110 OR 220 VOLTS AS DIRECTED BY THE GENERAL
CONTRACTOR. COORDINATE FOR ADDITIONAL TEMPORARY POWER REQUIREMENTS
WITH OTHER TRADES AND PROVIDE AN ADEQUATE INSTALLATION.
FURNISH AND INSTALL AN APPROVED TEMPORARY FIRE ALARM SYSTEM AS REQUIRED
BY LOCAL CODES AND AUTHORITY HAVING JURISDICTION.
ALL TEMPORARY ELECTRICAL EQUIPMENT SHALL BE REMOVED BEFORE THE AREA
CEILINGS ARE INSTALLED.
19. CABLING
BRANCH CIRCUITS TO RECEPTACLES, LIGHTING AND MISC. SMALL LOADS (15 OR 20 AMP
CIRCUITS), UNLESS SPECIFICALLY NOTED OTHERWISE, SHALL BE 2#12, 1#12G. - 3/4" C.
SEE NOTE BELOW FOR ADDITIONAL REQUIREMENTS. MINIMUM SIZE WIRE SHALL BE #12
AWG AND MINIMUM SIZE CONDUIT SHALL BE 3/4" TRADE SIZE.
20. CABLING SIZES
BRANCH CIRCUIT CABLE SIZING SHALL BE BASED ON THE VALUES INDICATED BELOW:
A. 120/208V CABLING FROM PANEL TO THE ELECTRICAL LOAD SHALL BE ADJUSTED
AS FOLLOWS UNLESS SPECIFICALLY NOTED OTHERWISE:
0' - 65' #12 AWG MINIMUM COPPER
66 - 100' #10 AWG MINIMUM COPPER
101' - 160' #8 AWG MINIMUM COPPER
161' - 250' #6 AWG MINIMUM COPPER
B. 277/480V CABLING FROM PANEL TO THE ELECTRICAL LOAD SHALL BE ADJUSTED
AS FOLLOWS UNLESS SPECIFICALLY NOTED OTHERWISE:
0' - 150' #12 AWG MINIMUM
150' - 250' #10 AWG MINIMUM
250' - 300' #8 AWG MINIMUM
22. SPECIAL LUG REQUIREMENTS
ANY CABLE WHICH TERMINATES DIRECTLY ON TO A BUS BAR SHALL BE 2 BOLT LONG
BARREL TYPE WITH INSPECTION HOLES PRODUCED WITH NON FLASHING TYPE DYES AS
MANUFACTURED BY THOMAS AND BETTS OR APPROVED EQUAL, MINIMUM 10 TONS OF
COMPRESSION, HEX CRIMP. THE USE OF HEAT SHRINK TUBING IS EXPLICITLY
FORBIDDEN. THERE SHALL BE NO "SHINERS" AT THE LUGS.
ELECTRICAL GENERAL NOTES
1. EXAMINATION
A. THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE AREAS UNDER WHICH
THE WORK IS TO BE PERFORMED AND NOTIFY THE OWNER IN WRITING OF ANY
CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE
WORK. CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL SATISFACTORY
CONDITIONS HAVE BEEN CORRECTED.
B. VERIFY FIELD MEASUREMENTS AND CIRCUITING ARRANGEMENTS FOR DEVICES
SHOWN ON DRAWINGS.
C. DEMOLITION DRAWINGS ARE BASED ON CASUAL FIELD OBSERVATION AND
EXISTING RECORD DRAWINGS. REPORT DISCREPANCIES TO OWNER BEFORE
DISTURBING EXISTING INSTALLATION.
D. COMMENCEMENT OF DEMOLITION MEANS ACCEPTANCE OF EXISTING
CONDITIONS.
2. PREPARATION
A. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS
SCHEDULED FOR REMOVAL.
B. COORDINATE ELECTRICAL SHUTDOWNS ONE WEEK IN ADVANCE WITH ARGONNE
NATIONAL LABORATORY PERSONNEL.
C. PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING
SYSTEMS IN SERVICE DURING CONSTRUCTION. EXPERIENCED PERSONNEL
SHALL BE USED WHEN WORKING ON ENERGIZED EQUIPMENT OR CIRCUITS.
D. EXISTING ELECTRICAL SERVICE: MAINTAIN EXISTING ELECTRICAL SYSTEM IN
SERVICE UNTIL NEW SERVICE IS COMPLETE AND READY FOR SERVICE. DISABLE
ELECTRICAL SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS.
MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN
ELECTRICAL SERVICE IN AREAS ADJACENT TO WORK AREA.
E. MAINTAIN EXISTING FIRE ALARM SYSTEM IN SERVICE UNTIL NEW SYSTEM IS
ACCEPTED. DISABLE SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS.
WHERE FIRE ALARM DEVICES MUST BE REMOVED TO ACCOMMODATE THE
REMOVAL OF WALLS, NOTIFY THE OWNER AND ENGINEER IN WRITING WITH
LOCATIONS OF DEVICES.
3. DEMOLITION AND EXTENSION OF EXISTING ELECTRICAL WORK.
A. REMOVE, RELOCATE, AND EXTEND EXISTING ELECTRICAL WORK AS INDICATED
ON THE DRAWINGS AND AS NOTED HEREIN.
B. REMOVE ABANDONED WIRING BACK TO SOURCE OF SUPPLY.
C. WHERE SOURCE OF SUPPLY IS A PANELBOARD, RE-LABEL PROTECTIVE DEVICE
AS "SPARE". AFTER DEMOLITION IS COMPLETE, SUBMIT REVISED PANELBOARD
SCHEDULES INDICATING "SPARES" TO OWNER AND ENGINEER.
D. REMOVE EXPOSED ABANDONED CONDUIT ABOVE ACCESSIBLE CEILING FINISHES.
CUT CONDUIT FLUSH WITH WALLS AND FLOORS, AND PATCH SURFACES.
E. DISCONNECT AND REMOVE ABANDONED OUTLETS AND ASSOCIATED DEVICES.
F. DISCONNECT AND REMOVE ABANDONED PANELBOARDS AND DISTRIBUTION
EQUIPMENT.
G. DISCONNECT AND REMOVE ELECTRICAL DEVICES AND EQUIPMENT THAT IS NO
LONGER IN USE.
H. DISCONNECT AND REMOVE ABANDONED LUMINARIES. REMOVE BRACKETS,
STEMS, HANGERS, AND ALL OTHER ACCESSORIES.
I. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING
DEMOLITION AND EXTENSION OF WORK.
4. CLEANING, REPAIR, AND REPLACEMENT
A. GENERAL: CLEAN AND REPAIR EXISTING MATERIALS AND EQUIPMENT THAT WILL
REMAIN OR ARE TO BE REUSED.
B. PANELBOARDS: CLEAN EXPOSED SURFACES AND TIGHTEN ALL ELECTRICAL
CONNECTIONS. REPLACE DAMAGED CIRCUIT BREAKERS AND PROVIDE CLOSURE
PLATES FOR VACANT POSITIONS. PROVIDE TYPED SCHEDULES SHOWING
REVISED CIRCUITING INFORMATION.
C. LUMINAIRES: REMOVE EXISTING LUMINAIRES FOR CLEANING. USE MILD
DETERGENT TO CLEAN EXTERIOR AND INTERIOR SURFACES, RINSE CLEAN WITH
CLEAN WATER AND WIPE DRY. REPLACE EXISTING LAMPS AND BALLASTS WITH
NEW.
5. DISPOSAL
A. OWNER SHALL HAVE RIGHT TO RETAIN ANY EQUIPMENT OR MATERIALS THAT
HAVE BEEN DEMOLISHED PRIOR TO DISPOSAL OR REMOVAL FROM SITE.
B. ANY EQUIPMENT OR MATERIALS NOT WANTED BY THE OWNER SHALL BECOME
THE PROPERTY OF THE CONTRACTOR AND REMOVED FROM SITE.
C. CONTRACTOR SHALL COMPLY WITH ENVIRONMENTAL LAWS AND REGULATIONS
FOR DISPOSAL OF DEMOLISHED MATERIALS AND EQUIPMENT.
GENERAL NOTES FOR DEMOLITION
FO
R
PR
EP
UR
CH
AS
E
ON
LY
NO
T
FO
R
CO
NS
TR
UC
TI
ON
SHUNT TRIPST
BLOWN FUSE DETECTOR AND RELAYBFD
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
FACILITY DOCUMENT NO.
AutoCAD SHX Text
CADD NUMBER
AutoCAD SHX Text
FACILITY NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
APVD
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
J420-104-W-E001.DWG
AutoCAD SHX Text B420
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text
JET
AutoCAD SHX Text A
AutoCAD SHX Text
PRE-PURCHASE REVIEW
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text 06-10-24
AutoCAD SHX Text B
AutoCAD SHX Text
ISSUED FOR PREPURCHASE
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text 09-03-24
AutoCAD SHX Text
LINETYPE LEGEND
AutoCAD SHX Text
DEMOLITION SYMBOLS
AutoCAD SHX Text
ELECTRICAL ABBREVIATIONS
AutoCAD SHX Text
ELECTRICAL RISER DIAGRAM SYMBOLS
POWER SYMBOLS
X X X X X X X
X X
X X
X X
X X
X X
XXXXXXX
X X
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXXX
X X
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXXX
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER)
(ER) (ER) (ER)
(ER)
(ER) (ER)
(ER)
(ER)
RF/EXTRACTION BUILDING MAIN
13.2kV LOAD INTERRUPTER SWITCHGEAR
J
(ER)
J TRPC-12: #2,4
TRPC-12: #2,4
EXISTING 15kV LOAD INTERRUPTER SWITCH
EXISTING THROAT CONNECTION
(CABLE DUCT SHALL REMAIN FOR
USE WITH NEW TRANSFORMER)
NEW NEMA-3R SWITCHBOARD MSB-SSA-1
TO BE INCLUDED IN THIS PREPURCHASE
EXISTING UNDERGROUND CABLE
AND CONDUIT SHALL REMAIN
GRC CONDUIT ABOVE GRADE
TO TRANSFORMER PER SINGLE
LINE DIAGRAM E401
NEW MEDIUM VOLTAGE TRANSFORMER TO
BE INCLUDED IN THIS PREPURCHASE
WARNING
IF PLAN IS ENLARGED OR REDUCED,
GRAPHIC SCALE SHALL BE USED.
J420-104-W- E100 0
BUILDING 420
S36 POWER & COOLING FOR SSA
ELECTRICAL
BUILDING EXTERIOR
NEW WORK
Grumman/Butkus Associates Energy Efficiency Consultants and Sustainable Design Engineers
820 Davis St, Ste 300 Evanston, Illinois 60201 4446 847 328.3555 www.grummanbutkus.com Copyright © 2023 Grumman/Butkus Associates Illinois Registration #184-000926 GBA Project: P23-0858-00
1 ELECTRICAL BUILDING EXTERIOR - NEW WORK
1/8"=1'-0"
20 4 8 16
1. CONTRACTOR TO PROVIDE AND INSTALL NEW FUSES IN EXISTING DISCONNECT SWITCH
TO FEED NEW TRANSFORMER. SEE SINGLE LINE DIAGRAM FOR FUSE REQUIREMENTS.
2. CONTRACTOR SHALL CONNECT EXISTING 208V CIRCUITS RETAINED FROM DEMOLITION
FOR QUALITROL FAN CONTROLLER AND FOR TRANSFORMER SPACE HEATERS.
CONTRACTOR SHALL CONNECT EXISTING RS-485 COMMUNICATION CIRCUIT FOR
QUALITROL TEMPERATURE MONITORING TO NEW TRANSFORMER TEMPERATURE
MONITORING DEVICE. ANL WILL CONNECT EXISTING CABLE INSIDE LABORATORY SPACE
TO NEW EXPERIMENT PLC/HMI FOR REMOTE MONITORING AND DATA DISPLAY.
3. CONTRACTOR SHALL SET, INSTALL, AND WIRE OWNER'S PREPURCHASED 2000kVA DRY
TYPE MEDIUM VOLTAGE TRANSFORMER. PROVIDE ALL CABLE TERMINATIONS AND
GROUNDING. HIGH VOLTAGE ENTRY LOCATION ON NEW TRANSFORMER TO MATCH
LOCATION FROM EXISTING TRANSFORMER. SEE DETAIL #1 ON SHEET E601 FOR EXISTING
TRANSFORMER DETAIL
4. CONTRACTOR SHALL SET AND WIRE OWNER'S PREPURCHASED MSB-SSA-1
SWITCHBOARD AS SHOWN AND INDICATED ON DRAWINGS E401. CONNECT TO
TRANSFORMER WITH NEW CABLE AND CONDUIT AS INDICATED. PROVIDE NEMA-3R
BUSDUCT CONNECTION TO SWITCHBOARD TO MATCH THE SAME MANUFACTURER AS THE
OWNER'S PREPURCHASED SWITCHBOARDS MSB-SSA-1 AND MSB-SSA-2.
5. USE SAME 208V, 20A CIRCUIT (TRPC-12: #2,4) USED FOR TRANSFORMER
FANS/TEMPERATURE CONTROL AND MEDIUM VOLTAGE LOAD INTERRUPTER SWITCH
SHUNT TRIP CIRCUIT TO SERVE THE NEW ANTI-CONDENSATION STRIP HEATERS INSIDE
NEW MSB-SSA-1.
CONSTRUCTION PLAN NOTES#
GENERAL NOTES
A. REFER TO DRAWING E001 FOR SYMBOLS AND ABBREVIATIONS.
B. THE CONTRACTOR SHALL PERFORM COMPLETE ARC FLASH, COORDINATION, AND SHORT
CIRCUIT STUDY AS SPECIFIED IN SPECIFICATION SECTION 26 05 73.
C. THE CONTRACTOR MUST FOLLOW ALL ARGONNE LOCK OUT TAG OUT PROCEDURES IN
ADDITION TO THE REQUIREMENTS OUTLINED BY OSHA.
D. THE OWNER RESERVES THE RIGHT TO RETAIN ANY MATERIALS REMOVED FROM DEMOLITION
ACTIVITIES. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ALL MATERIALS AND
APPARATUS SCHEDULED TO BE REMOVED AND SHALL TURN OVER ALL ITEMS INDICATED BY
THE OWNER TO BE SALVAGED.
E. EACH AND EVERY POWER CONNECTION MUST HAVE A PRINTED LABEL INDICATING THE
SOURCE PANELBOARD AND CIRCUIT NUMBER.
F. ANL TO PROVIDE THE NATIVE ETAP MODEL FOR THE BUILDING TO THE CONTRACTOR. THE
CONTRACTOR SHALL UPDATE THE MODEL AND SEND THE NATIVE FILE BACK WITH ANY AND
ALL CHANGES. THE CONTRACTOR SHALL PROVIDE AND INSTALL NEW ARC-FLASH LABELS ON
THE EQUIPMENT INVOLVED IN THE STUDY AS PRODUCED BY THE UPDATED MODEL.
G. THE CONTRACTOR SHALL COORDINATE ALL BUSWAY ROUTING WITH EXISTING AND NEW
CONDITIONS INCLUDING FEATURES SUCH AS PIPING, DUCTWORK, SCAFFOLDING,
CABLE-TRAYS, WAVEGUIDES, STRUCTURE, AND ALL OTHERS. THESE DRAWINGS ARE
PROVIDED FOR THE PURPOSE OF ESTABLISHING A BASIS OF DESIGN ROUTING, BUT MAY NOT
DEPICT ALL FEATURES AND OBSTACLES WITHIN THE ROUTE. THE CONTRACTOR SHALL
SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD AND ARGONNE NATIONAL
LABORATORY PRIOR TO RELEASING FOR FABRICATION.
E601
FO
R
PR
EP
UR
CH
AS
E
ON
LY
NO
T
FO
R
CO
NS
TR
UC
TI
ON
1. THIS DRAWING IS PROVIDED FOR REFERENCE ONLY
SPECIAL NOTE FOR PREPURCHASE
AutoCAD SHX Text
RF-1 STAGING
AutoCAD SHX Text A001
AutoCAD SHX Text
RF-2
AutoCAD SHX Text A009
AutoCAD SHX Text
RF-2 STAGING
AutoCAD SHX Text A008
AutoCAD SHX Text
TRUCK AIR LOCK
AutoCAD SHX Text A010
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
FACILITY DOCUMENT NO.
AutoCAD SHX Text
CADD NUMBER
AutoCAD SHX Text
FACILITY NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
APVD
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
J420-104-W-E100.DWG
AutoCAD SHX Text B420
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text
JET
AutoCAD SHX Text A
AutoCAD SHX Text
PRE-PURCHASE REVIEW
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text 06-10-24
AutoCAD SHX Text B
AutoCAD SHX Text
ISSUED FOR PREPURCHASE
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text 09-03-24
36.00"
36.00" MAX
36.00"
48" MIN
(TYP.) WAVEGUIDES ARE AT
9'-6" FROM FINISHED FLOOR
TO BOTTOM OF WAVEGUIDE.
NOTE - DIMENSIONS INDICATED ARE
BASED ON SQUARE-D SWITCHBOARD
EQUIPMENT AND MAY VARY.
47.19"
MSB-SSA-2
TO BE INCLUDED IN THIS
EQUPIMENT PREPURCHASE
PDP-SSA-36-C4
TO BE INCLUDED IN THIS
EQUPIMENT PREPURCHASE
PDP-SSA-36-C3
TO BE INCLUDED IN THIS
EQUPIMENT PREPURCHASE
PDP-SSA-36-C2
TO BE INCLUDED IN THIS
EQUPIMENT PREPURCHASE
PDP-SSA-36-C1
TO BE INCLUDED IN THIS
EQUPIMENT PREPURCHASE
WARNING
IF PLAN IS ENLARGED OR REDUCED,
GRAPHIC SCALE SHALL BE USED.
J420-104-W- E101N 0
BUILDING 420
SOLID STATE AMPLIFIER
ELECTRICAL
FIRST FLOOR S36 NORTH
NEW WORK
Grumman/Butkus Associates Energy Efficiency Consultants and Sustainable Design Engineers
820 Davis St, Ste 300 Evanston, Illinois 60201 4446 847 328.3555 www.grummanbutkus.com Copyright © 2023 Grumman/Butkus Associates Illinois Registration #184-000926 GBA Project: P23-0858-00
1 ELECTRICAL FIRST FLOOR POWER PLAN - MODULE S36 NORTH
1/4"=1'-0"
0 41 2 8
CONSTRUCTION PLAN NOTES#
GENERAL NOTES
A. REFER TO DRAWING E001 FOR SYMBOLS AND ABBREVIATIONS.
B. THE CONTRACTOR SHALL PERFORM COMPLETE ARC FLASH, COORDINATION, AND SHORT
CIRCUIT STUDY AS SPECIFIED IN SPECIFICATION SECTION 26 05 73.
C. THE CONTRACTOR MUST FOLLOW ALL ARGONNE LOCK OUT TAG OUT PROCEDURES IN
ADDITION TO THE REQUIREMENTS OUTLINED BY OSHA.
D. THE OWNER RESERVES THE RIGHT TO RETAIN ANY MATERIALS REMOVED FROM DEMOLITION
ACTIVITIES. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ALL MATERIALS AND
APPARATUS SCHEDULED TO BE REMOVED AND SHALL TURN OVER ALL ITEMS INDICATED BY
THE OWNER TO BE SALVAGED.
E. EACH AND EVERY POWER CONNECTION MUST HAVE A PRINTED LABEL INDICATING THE
SOURCE PANELBOARD AND CIRCUIT NUMBER.
F. ANL TO PROVIDE THE NATIVE ETAP MODEL FOR THE BUILDING TO THE CONTRACTOR. THE
CONTRACTOR SHALL UPDATE THE MODEL AND SEND THE NATIVE FILE BACK WITH ANY AND
ALL CHANGES. THE CONTRACTOR SHALL PROVIDE AND INSTALL NEW ARC-FLASH LABELS ON
THE EQUIPMENT INVOLVED IN THE STUDY AS PRODUCED BY THE UPDATED MODEL.
G. THE CONTRACTOR SHALL COORDINATE ALL BUSWAY ROUTING WITH EXISTING AND NEW
CONDITIONS INCLUDING FEATURES SUCH AS PIPING, DUCTWORK, SCAFFOLDING,
CABLE-TRAYS, WAVEGUIDES, STRUCTURE, AND ALL OTHERS. THESE DRAWINGS ARE
PROVIDED FOR THE PURPOSE OF ESTABLISHING A BASIS OF DESIGN ROUTING, BUT MAY NOT
DEPICT ALL FEATURES AND OBSTACLES WITHIN THE ROUTE. THE CONTRACTOR SHALL
SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD AND ARGONNE NATIONAL
LABORATORY PRIOR TO RELEASING FOR FABRICATION.
1. PROVIDE NEW 3000A, 480Y/277V 3P, 4W + GND. SWITCHBOARD. SWITCHBOARD TO
INCLUDE 65kAIC INSULATED CASE MAIN BREAKER WITH LSIG TRIP UNIT AND POWER
METER PER SPECIFICATION SECTION 26 2413 . SEE DETAIL #3 ON SHEET E601 FOR
ADDITIONAL INFORMATION.
2. PROVIDE NEW 600A, 480V 3P, 4W + GND. WALL MOUNTED DISTRIBUTION
PANELBOARD EQUIPPED WITH A 600A MAIN BREAKER WITH 120V SHUNT TRIP AND (2)
250A 3P BRANCH BREAKERS, HINGED FRONT COVERS, AND NEW POWER METER
AHEAD OF THE MAIN CIRCUIT BREAKER PER SPECIFICATION SECTION 26 2416.
3. THIS DISTRIBUTION SECTION (SECTION #3) SHALL BE SHIPPED AS ITS OWN SPLIT PER
THE SINGLE LINE DRAWING J420-104-W-E401 AND WILL BE INSTALLED IN FUTURE
PHASE IN FUTURE LOCATION TO BE DETERMINED.
FO
R
PR
EP
UR
CH
AS
E
ON
LY
NO
T
FO
R
CO
NS
TR
UC
TI
ON
1. THIS DRAWING IS PROVIDED FOR REFERENCE ONLY
SPECIAL NOTE FOR PREPURCHASE
AutoCAD SHX Text
ELECTRONICS
AutoCAD SHX Text
RF-2 STAGING
AutoCAD SHX Text A008
AutoCAD SHX Text
EXPERIMENT HALL
AutoCAD SHX Text D
AutoCAD SHX Text 05-A
AutoCAD SHX Text 6'-0"
AutoCAD SHX Text 7'-2"
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text M
AutoCAD SHX Text
AutoCAD SHX Text
PT
AutoCAD SHX Text 1 3/4"
AutoCAD SHX Text C
AutoCAD SHX Text
PT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXPERIMENT HALL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
FACILITY DOCUMENT NO.
AutoCAD SHX Text
CADD NUMBER
AutoCAD SHX Text
FACILITY NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
APVD
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
J420-104-W-E101N.DWG
AutoCAD SHX Text B420
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text
JET
AutoCAD SHX Text A
AutoCAD SHX Text
PRE-PURCHASE REVIEW
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text 06-10-24
AutoCAD SHX Text B
AutoCAD SHX Text
ISSUED FOR PREPURCHASE
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text 09-03-24
TRPC-R18
TRPC-12
RF-C
TRPC-12
TRPC-R18
TRANSFORMER
(ON MEZZANINE ABOVE)
LADDER UP TO
MEZZANINE
J
MSB-SSA-1
TO BE INCLUDED IN THIS
EQUPIMENT PREPURCHASE
NEW MEDIUM VOLTAGE
TRANSFORMER TO BE INCLUDED
IN THIS PREPURCHASE
36.00"
8.75"
51.00"
GRC CONDUIT ABOVE GRADE
TO TRANSFORMER PER
SINGLE LINE DIAGRAM E401
AND PER DRAWING
E601 DETAIL #2
EXISTING CABLE
TRAY ~15'-0" AFF TO
BOTTOM OF TRAY.
108.00"
66.00"
WARNING
IF PLAN IS ENLARGED OR REDUCED,
GRAPHIC SCALE SHALL BE USED.
J420-104-W E101S 0
BUILDING 420
SOLID STATE AMPLIFIER
ELECTRICAL
FIRST FLOOR S36 SOUTH
NEW WORK
Grumman/Butkus Associates Energy Efficiency Consultants and Sustainable Design Engineers
820 Davis St, Ste 300 Evanston, Illinois 60201 4446 847 328.3555 www.grummanbutkus.com Copyright © 2023 Grumman/Butkus Associates Illinois Registration #184-000926 GBA Project: P23-0858-00
1 ELECTRICAL FIRST FLOOR POWER PLAN - MODULE S36 SOUTH
1/4"=1'-0"
0 41 2 8
1. EXISTING CONDUIT CONTAINING EXISTING TRANSFORMER HEATER CIRCUIT AND
RS-485 TEMPERATURE MONITORING CIRCUIT. CONTRACTOR TO EXTEND TO NEW
TRANSFORMER.
2. EXISTING CONDUIT CONTAINING EXISTING RS-485 TEMPERATURE MONITORING
CIRCUIT WHICH SHALL BE EXTENDED TO NEW LABORATORY SSA PLC CONTROLLER.
3. NEW JUNCTION BOX WITH TERMINAL STRIP PROVIDED TO INTERCEPT AND EXTEND
EXISTING RS-485 TEMPERATURE MONITORING CIRCUIT TO NEW LABORATORY SSA
PLC CONTROLLER.
4. INTERCEPT EXISTING GROUND RING USED FOR EXISTING TRANSFORMER AND
ROUTE INTO NEW TRANFORMER. CONNECT TO GROUND BUS IN TRANSFORMER
ENCLOSURE. REFER TO DRAWING E401 FOR CONNECTION DETAIL.
CONSTRUCTION PLAN NOTES#
GENERAL NOTES
A. REFER TO DRAWING E001 FOR SYMBOLS AND ABBREVIATIONS.
B. THE CONTRACTOR SHALL PERFORM COMPLETE ARC FLASH, COORDINATION, AND SHORT
CIRCUIT STUDY AS SPECIFIED IN SPECIFICATION SECTION 26 05 73.
C. THE CONTRACTOR MUST FOLLOW ALL ARGONNE LOCK OUT TAG OUT PROCEDURES IN
ADDITION TO THE REQUIREMENTS OUTLINED BY OSHA.
D. THE OWNER RESERVES THE RIGHT TO RETAIN ANY MATERIALS REMOVED FROM DEMOLITION
ACTIVITIES. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ALL MATERIALS AND
APPARATUS SCHEDULED TO BE REMOVED AND SHALL TURN OVER ALL ITEMS INDICATED BY
THE OWNER TO BE SALVAGED.
E. EACH AND EVERY POWER CONNECTION MUST HAVE A PRINTED LABEL INDICATING THE
SOURCE PANELBOARD AND CIRCUIT NUMBER.
F. ANL TO PROVIDE THE NATIVE ETAP MODEL FOR THE BUILDING TO THE CONTRACTOR. THE
CONTRACTOR SHALL UPDATE THE MODEL AND SEND THE NATIVE FILE BACK WITH ANY AND
ALL CHANGES. THE CONTRACTOR SHALL PROVIDE AND INSTALL NEW ARC-FLASH LABELS ON
THE EQUIPMENT INVOLVED IN THE STUDY AS PRODUCED BY THE UPDATED MODEL.
G. THE CONTRACTOR SHALL COORDINATE ALL BUSWAY ROUTING WITH EXISTING AND NEW
CONDITIONS INCLUDING FEATURES SUCH AS PIPING, DUCTWORK, SCAFFOLDING,
CABLE-TRAYS, WAVEGUIDES, STRUCTURE, AND ALL OTHERS. THESE DRAWINGS ARE
PROVIDED FOR THE PURPOSE OF ESTABLISHING A BASIS OF DESIGN ROUTING, BUT MAY NOT
DEPICT ALL FEATURES AND OBSTACLES WITHIN THE ROUTE. THE CONTRACTOR SHALL
SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD AND ARGONNE NATIONAL
LABORATORY PRIOR TO RELEASING FOR FABRICATION.
FO
R
PR
EP
UR
CH
AS
E
ON
LY
NO
T
FO
R
CO
NS
TR
UC
TI
ON
1. THIS DRAWING IS PROVIDED FOR REFERENCE ONLY
SPECIAL NOTE FOR PREPURCHASE
AutoCAD SHX Text
MAGNET
AutoCAD SHX Text
ELECTRONICS
AutoCAD SHX Text A005
AutoCAD SHX Text
RF-1 STAGING
AutoCAD SHX Text A001
AutoCAD SHX Text
RF-2
AutoCAD SHX Text A009
AutoCAD SHX Text
RF-2 STAGING
AutoCAD SHX Text A008
AutoCAD SHX Text J.C.
AutoCAD SHX Text A006
AutoCAD SHX Text
TOILET
AutoCAD SHX Text A007
AutoCAD SHX Text
FE-1
AutoCAD SHX Text
FE-1
AutoCAD SHX Text
OPP. HAND
AutoCAD SHX Text 755.70
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text 755.70
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
TRUCK AIR LOCK
AutoCAD SHX Text A010
AutoCAD SHX Text
UP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text A.6
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
FACILITY DOCUMENT NO.
AutoCAD SHX Text
CADD NUMBER
AutoCAD SHX Text
FACILITY NUMBER
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BY
AutoCAD SHX Text
APVD
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
J420-104-W-E101S.DWG
AutoCAD SHX Text B420
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text
JET
AutoCAD SHX Text A
AutoCAD SHX Text
PRE-PURCHASE REVIEW
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text 06-10-24
AutoCAD SHX Text B
AutoCAD SHX Text
ISSUED FOR PREPURCHASE
AutoCAD SHX Text
SJD
AutoCAD SHX Text
SSC
AutoCAD SHX Text 09-03-24
S-R11 N.C.
S-R12 N.O.
200E
S-R13 N.C.
S-R14 N.O.
200E
S-R9 N.C.
S-R10 N.O.
200E
S-R7 N.C.
S-R8 N.O.
200E
S-R5 N.C.
S-R6 N.O.
200E
TO SWITCHGEAR S2 BUS 2
TO SWITCHGEAR S1 BUS 1
EXISTING RF/EXTRACTION BUILDING OUTDOOR 13.2kV LOAD
INTERRUPTER SWITCHGEAR
NEW PREPURCHASED DRY TYPE MV NEMA-3R TRANSFORMER
2000/2666kVA AA/FA @ 80°C RISE
2700/3600kVA AA/FA @ 150°C RISE
13.2KV PRIMARY
480Y/277V SECONDARY
Z% = 5.75%
150E
MSB-SSA-2
3000A 480Y/277V
3-PHASE, 4-WIRE,
65kA RATED BUSSING AND BRANCH BREAKERS
SECT. 1SECT. 2
PM 3000:5A
4CT
K1 K1
LO LO
K1
EXISTING 15kV LOAD
INTERRUPTER SWITCH AT
TRANSFORMER
VTS
GRACE VOLTAGE
TEST STATION PER
SPECIFICATIONS
3000A COPPER BUS
ST
MAIN CIRCUIT
BREAKER W/120V
SHUNT TRIP
TYPICAL NEW SSA PANELBOARD
EPO
EMERGENCY POWER
OFF (EPO) BUTTON
TURN TO RESET TYPE
H
N
TO TECHNICAL
POWER PANEL -
SEE PLANS FOR
CIRCUIT NUMBERS
SPD
SURGE PROTECTIVE
DEVICE PER
SPECIFICATIONS
600A/3P
3000A COPPER BUS
SECT. 3
SHOWN FOR REFERENCE, NOT IN CONTRACT:
3000A CU 3P, 4W, WITH 50% GROUND BAR
CONTRACTOR'S FEEDER BUSDUCT BUSDUCT SHALL
MATCH MANUFACTURER (OR INTERIOR BUS DETAILS)
OF SWITCHBOARD. BUSDUCT IS NOT IN THIS
CONTRACT.
N
G
G N
NEUTRAL SHALL
BE UNBONDED AT
TRANSFORMER
CONNECT TO EXISTING
GROUNDING RING AT TRANSFORMER
FOUNDATION WITH #4/0 CU
EXOTHERMIC WELDED
GROUNDING SPLICE PER UL
BUSWAY FLANGE TO JOIN BUSDUCT TO
SWITCHBOARD. BUSWAY FLANGE TO MATCH
SWITCHBOARD MANUFACTURER
LC
K1 K1
LO LO
LC
K1
K1 K1
LO LO
LC
K1
K1 K1
LO LO
LC
K1
K1 K1
LO LO
LC
K1
NEW 3-1/C #1/0 COPPER NON-SHIELDED 15kV CABLE BY TRANSFORMER
MANUFACTURER SHIPPED IN 150 FOOT LENGTH (50 FEET PER PHASE) AND TO
BE INSTALLED AND TERMINATED BY ELECTRICAL CONTRACTOR. ELECTRICAL
CONTRACTOR SHALL INSTALL CABLING IN EXISTING THROAT CONNECTION
BETWEEN EXISTING LOAD INTERRUPTER SWITCH AND NEW TRANSFORMER
USING EXISTING SUPPORT INSULATORS/GLASTIC PANELS.
NEW 150E FUSES TO MATCH
EXISTING TYPES IN LOAD
INTERRUPTER SWITCH
EXISTING UNDERGROUND
CABLE AND CONDUIT
EXISTING 208V SHUNT TRIP:
TRPC-12: #2,4
3LA
15kV
12.7MCOV
ST
G
#12 AWG, 3/4"C
MSB-SSA-1
NEW 3000A 480Y-277V NEMA-3R UL
SERVICE ENTRANCE RATED
SWITCHBOARD. PROVIDED AS
PREPURCHASED EQUIPMENT.G N
ST
8 SETS OF
4-500KCMIL, 1#3/0G,
3 1/2" GRC
TO MSB-SSA-2
2#12, 1#12G, 3/4" C
SEE PLANS FOR CIRCUIT
2#12, 1#12G, 3/4" C
TO MSB-SSA-1
SEE PLANS FOR PANEL
AND CIRCUIT NUMBER
3000A
LSIG
ARMS
100%
RATED
208V - 1Ø TO
TRPC-12
ANTI-COND.
HEATER
600A
LSI
600A
LSI
600AF
600AT
PM 600:5A
4CT
ST
250AF
250AT
250AF
250AT
PM 600:5A
4CT
250AF
250AT
250AF
250AT
PM 600:5A
4CT
250AF
250AT
250AF
250AT
PM 600:5A
4CT
250AF
250AT
250AF
250AT
PDP-SSA-36-C1
480V 3Ø-4W 35kA RATED
PDP-SSA-36-C3
480V 3Ø-4W 35kA RATED
PDP-SSA-36-C4
480V 3Ø-4W 35kA RATED
PDP-SSA-36-C2
480V 3Ø-4W 35kA RATED
600A
LSI
600A
LSI
600A
LSI
600A
LSI
600A
LSI
600A
LSI
600A
LSI
600A
LSI
600A
LSI
EPO
120V POWER BY E.C.
SHALL BE PROVIDED TO
SHUNT TRIP OPERATOR.
SEE DETAIL #2 ON THIS
DRAWING
600AF
600AT
600AF
600AT
600AF
600ATST
EPO
ST
EPO
ST
EPO
TYPICAL: 120VAC SHUNT TRIP
ON MAIN
POWER
DISTRIBUTION
STYLE PANEL
POWER
DISTRIBUTION
STYLE PANEL
POWER
DISTRIBUTION
STYLE PANEL
POWER
DISTRIBUTION
STYLE PANEL
(2) SETS OF 4#350kCMIL, 1#1G, 3"C
2#12, 1#12G, 3/4"C
TO EACH EPO
SEE PLANS FOR CIRCUIT #
SPARESPARE SPARESPARESPARESPARESPARESPARE
600A
LSI
PDP-SSA-36-C1
480V 3Ø-4W 35kA RATED
WIRING BY OTHERS
TYPICAL - EPO BUTTONS
PROVIDED BY OTHERS;
NOT IN THIS CONTRACT
BUSWAY FLANGE TO JOIN BUSDUCT
TO SWITCHBOARD. BUSWAY FLANGE
TO MATCH SWITCHBOARD
MANUFACTURER
WARNING
IF PLAN IS ENLARGED OR REDUCED,
GRAPHIC SCALE SHALL BE USED.
J420-104-W- E401 0
BUILDING 420
SOLID STATE AMPLIFIER
ELECTRICAL
SINGLE LINE
DIAGRAM
Grumman/Butkus Associates Energy Efficiency Consultants and Sustainable Design Engineers
820 Davis St, Ste 300 Evanston, Illinois 60201 4446 847 328.3555 www.grummanbutkus.com Copyright © 2023 Grumman/Butkus Associates Illinois Registration #184-000926 GBA Project: P23-0858-00
GENERAL NOTES
A. REFER TO DRAWING E001 FOR SYMBOLS AND ABBREVIATIONS.
B. THE CONTRACTOR SHALL PERFORM COMPLETE ARC FLASH, COORDINATION, AND SHORT
CIRCUIT STUDY AS SPECIFIED IN SPECIFICATION SECTION 26 05 73.
C. THE CONTRACTOR MUST FOLLOW ALL ARGONNE LOCK OUT TAG OUT PROCEDURES IN
ADDITION TO THE REQUIREMENTS OUTLINED BY OSHA.
D. THE OWNER RESERVES THE RIGHT TO RETAIN ANY MATERIALS REMOVED FROM DEMOLITION
ACTIVITIES. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER ALL MATERIALS AND
APPARATUS SCHEDULED TO BE REMOVED AND SHALL TURN OVER ALL ITEMS INDICATED BY
THE OWNER TO BE SALVAGED.
E. EACH AND EVERY POWER CONNECTION MUST HAVE A PRINTED LABEL INDICATING THE
SOURCE PANELBOARD AND CIRCUIT NUMBER.
F. ANL TO PROVIDE THE NATIVE ETAP MODEL FOR THE BUILDING TO THE CONTRACTOR. THE
CONTRACTOR SHALL UPDATE THE MODEL AND SEND THE NATIVE FILE BACK WITH ANY AND
ALL CHANGES. THE CONTRACTOR SHALL PROVIDE AND INSTALL NEW ARC-FLASH LABELS ON
THE EQUIPMENT INVOLVED IN THE STUDY AS PRODUCED BY THE UPDATED MODEL.
G. THE CONTRACTOR SHALL COORDINATE ALL BUSWAY ROUTING WITH EXISTING AND NEW
CONDITIONS INCLUDING FEATURES SUCH AS PIPING, DUCTWORK, SCAFFOLDING,
CABLE-TRAYS, WAVEGUIDES, STRUCTURE, AND ALL OTHERS. THESE DRAWINGS ARE
PROVIDED FOR THE PURPOSE OF ESTABLISHING A BASIS OF DESIGN ROUTING, BUT MAY NOT
DEPICT ALL FEATURES AND OBSTACLES WITHIN THE ROUTE. THE CONTRACTOR SHALL
SUBMIT SHOP DRAWINGS TO THE ENGINEER OF RECORD AND ARGONNE NATIONAL
LABO…