This document is a set of bid drawings prepared by Kueny Architects, LLC for the Kenosha County Victim Witness, Juvenile Intake, and District Attorney Relocation and Partial Remodel Project located at 912 56th Street, Kenosha, Wisconsin 53140, dated April 24, 2020. The project encompasses interior remodeling across three phases in the Kenosha County Courthouse basement and Molinaro Building first floor. Phase I (Area 01) involves converting a 570 square foot existing conference room and vestibule into a new waiting area with new metal stud walls and interior finishes. Phase II (Area 02) consists of 1,800 square feet of full interior remodeling with new partition walls, flooring, painting, ceilings, and millwork, including a new reception window and kitchenette area. Phase III (Area 03) encompasses 2,000 square feet of partial interior remodeling with a new reception counter and kitchenette area. The drawings include comprehensive site plans, floor plans, ceiling plans, sections, details, electrical and technology plans, HVAC plans, and finish schedules for all three work areas.

The bid drawings specify detailed construction requirements including concrete testing at 4,000 psi, metal stud partition framing, gypsum board finishes, acoustical ceiling systems, carpet tile flooring with vinyl base, paint finishes, door and hardware schedules, and specialty features such as bullet-resistant glazing and wall systems for the reception areas in Area 03 (UL Level III rated). All contractors are required to obtain necessary permits, verify existing conditions in the field, coordinate with county IT and electrical systems, and protect adjacent areas during construction. The drawings note that existing underground utility locations are approximate and contractors must independently verify exact locations before commencing work. Multiple alternates are included, such as LED lighting upgrades in Areas 02 and 03, with associated costs to be determined. Millwork specifications include base and wall cabinets, solid surface countertops, and open shelving with specific dimensions detailed in the interior elevations and sections.

View the file

Other files

File Type Posted
2008 Addendum 1.pdf PDF
2008 KCJIDA_Bid Specs - 2020.04.24.pdf PDF
2008 Bid Documents.pdf PDF
2008 Addendum 3.pdf PDF
2008 Addendum 2.pdf PDF
Vendor Responsibility Form Construction.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1.0KUENY ARCHITECTS, LLC

10505 CORPORATE DRIVE - SUITE 100 PLEASANT PRAIRIE, WI 53158 PHONE (262) 857-8101 FAX (262) 857 8103

SITE MAP GENERAL NOTES

1. All concrete to test 4000 psi in 28 days.

2. Verify all dimensions, access, utilities and working conditions in the field.

3. Conform to all applicable codes, ordinances and safety standards.

4. Obtain and pay for all required permits and fees.

5. Notify Architect immediately if work cannot proceed as shown on Drawings or as described in the

Specifications.

6. No concrete to be poured without Architect's prior review.

7. All Contractor's to co-operate with all trades, Owner's and Architect's representatives.

8. Leave site clean, neat and free of debris at all times.

9. Each Prime and Sub-contractor is responsible for having read each page of the Specifications, Drawings, Addenda and Change Orders.

10. Guard against interfering with Owner's operations.

11. These Drawings contain no provisions or procedures for on-site safety. Each Contractor and their employees are responsible to follow all laws and ordinances and provide their own engineering to provide a safe work place.

12. The locations of existing underground utilities, shown on these Drawings, are shown in an approximate way only and have not been independently verified by the Owner or its representatives. The Contractor shall determine the exact location of all existing utilities before commencing work, and agrees to be fully responsible for any and all damages which might be occassioned by the Contractor's failure to exactly locate and preserve any and all underground utilities.

13. Services perform for this project have been conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing in this area under similar budget and time constraints. No warranty, expressed or implied, is made.

MATERIAL INDICATIONS DRAWING LEGEND

New or Required Point Elevation

Existing Point Elevation

Existing Contours

New or Required Contours

A Grid Lines

3.1

Building Section

Wall Section

Room/Space Number

Door Number

SHEET INDEX

Earth Backfill

Rigid Insulation

Concrete Block

Aluminum

Lumber (Rough)

Steel

Sand Fill

Concrete

Finished Wood

Stone Fill

Plywood

Batt Insulation

4.1

Room Name

101A Interior Elevation

Detail Section

5.1

7.1

5.1

Detail Number

Page Number

Exterior Elevation

2.1

# Wall Tag

+ 100.0

+ 100.0

+ 100.0

+ 100.0

CONSULTANTS

OH Door Number

OH

101A

Kenosha County

Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

912 56th St, Kenosha, WI 53140

April 24, 2020

Kenosha County Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

TITLE SHEET

01 Title Sheet

GENERAL ARCHITECTURE

A001 Work Area and Phasing Key Plan A002 Wall Types & Typical Details

ARCHITECTURAL

1A200 Area 01 - Existing and Demo 1A201 Area 01 - Plans and Details 1A202 Area 01 - Ceiling & Finish Plans 1IT200 Area 01 - Technology & Electrical Plan 2A200 Area 02 - Existing and Demo Plans 2A201 Area 02 - Proposed Floor Plan 2A202 Area 02 - Finish Plans 2A300 Area 02 - Sections and Details 2A400 Area 02 - Ceiling Plans 2IT200 Area 02 - Technology & Electrical Plans 2M200 Area 02 - HVAC Plan 3A200 Area 03 - Existing and Demo Plan 3A201 Area 03 - Proposed Plan 3A202 Area 03 - Finish Plans 3A300 Area 03 - Sections and Details 3A400 Area 03 - Ceiling Plans 3IT200 Area 03 - Technology & Electrical Plans

ARCHITECT Kueny Architects 10505 Corporate Drive, Suite 100

(262) 857-8101 Pleasant Prairie, Wisconsin 53158 Architect of Record - Jon P. Wallenkamp Project Contact - Lee Anderson (262) 945-7709

PROJECT

LOCATION

BID SET DRAWINGS

8 7.0 000

1 20. 0000

4 2.0 000

4 2.0 000

2 0.0 000

WORK AREA 02

PHASE II

JUVENILE INTAKE

1,800 SF

WORK AREA 01

PHASE I

PROPOSED VICTIM WITNESS

570 SF

WORK AREA 03

PHASE III

DA AREA REMODEL

2,000 SF

BASEMENT LEVEL

FIRST FLOOR

WORK AREA 03

PHASE IV

DA AREA REMODEL

150 SF

EXISTING

ELECTRICAL

AT IT ROOM

USE FOR DATA

AND ELECTRICAL -

AREA 01;

COORDINATE

WITH COUNTY

EXISTING IT

ROOM 02

USE FOR DATA

PULL IN AREA 02;

COORDINATE

WITH COUNTY

EXISTING PANEL

USE FOR ELECTRICAL IN

AREA 02; COORDINATE

WITH COUNTY

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

SCALE: 3/32" = 1'-0"

A001Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Work Area and Phasing Key Plan

912 56th St, Kenosha, WI 53140

WALL BASE PER ROOM FINISH SCHEDULE

FLOOR FINISH PER SCHEDULES AND

DETAILS

CONTINUOUS STEEL STUD

RUNNER; ANCHOR TO FLOOR STRUCTURE

5/8" GYPSUM BOARD; EACH SIDE

ACOUSTICAL BATT INSULATION; TYPICAL

AT ACOUSTICAL PARTITIONS

FINISH CEILING PER SCHEDULES AND

WALL SECTIONS

UNDERSIDE OF STRUCTURE

EXTEND TO UNDERSIDE OF STRUCTURE

AND SEAL PER SCHEDULES AND DETAILS

W A

LL

H

E

IG

H T

P E

R S

C H

E D

U

LE

S

WALL EXTENDED PAST FINISH CEILING;

SEE BRACING DETAIL

A STEEL STUD PARTITION

A1 3-5/8" STEEL STUD; 16" 0.C. / WALL EXTENSION 6" PAST FINISH CEILING

A2 3-5/8" STEEL STUD; 16" 0.C. / WALL EXTENSION TO STRUCTURE

WALL BASE PER ROOM FINISH SCHEDULE

FLOOR FINISH PER SCHEDULES AND

DETAILS

CONTINUOUS STEEL STUD

RUNNER; ANCHOR TO FLOOR STRUCTURE

5/8" GYPSUM BOARD; ONE SIDE

ACOUSTICAL BATT INSULATION; TYPICAL

AT ACOUSTICAL PARTITIONS

FINISH CEILING PER SCHEDULES AND

WALL SECTIONS

UNDERSIDE OF STRUCTURE

EXTEND TO UNDERSIDE OF STRUCTURE

AND SEAL PER SCHEDULES AND DETAILS

W A

LL

H

E

IG

H T

P E

R S

C H

E D

U

LE

S

WALL EXTENDED PAST FINISH CEILING;

SEE BRACING DETAIL

B STEEL STUD PARTITION

B1 3-5/8" STEEL STUD; 16" 0.C. / WALL EXTENSION 6" PAST FINISH CEILING

B2 3-5/8" STEEL STUD; 16" 0.C. / WALL EXTENSION TO STRUCTURE

B3 2-1/2" STEEL STUD; 16" 0.C. / WALL EXTENSION 6" PAST FINISH CEILING

B4 2-1/2" STEEL STUD; 16" 0.C. / WALL EXTENSION TO STRUCTURE

FINISHED CEILING PER SCHEDULES

AND DETAILS

METAL STUD KICKERS @ 36" O.C.

TO STRUCTURE; SAME GA AS WALL

FRAMING; STAGGER KICKERS

WALL TYPE PER SCHEDULES AND

FLOOR PLANS

WALL PER PLAN; SEE FLOOR

PLAN FOR WALL TYPE

SEAL EDGE WITH CLEAR

SILICON

1/4" CLEAR TEMPERED GLASS;

OFFSET GLAZING TO ONE SIDE

OF WALL

EXTERIOR GLAZING PER PLANS

AND SCHEDULES

WINDOW BLINDS PER PLANS

ALUMINUM CAP; SEE PLAN

FOR WALL THICKNESS

LEVEL PER PLANS

0'-0"

C E

IL

IN

G H

E

IG

H T

P E

R P

LA

N

S

H E

IG

H

T P

E R

P

LA

N S

4"

WIDTH PER PLANS 1"

M

IN

IM

U

M

1' -8

H

E

IG

H T

P E

R P

LA

N

S

WALL BASE PER ROOM

FINISH SCHEDULE

PVC EDGING TYPICAL ON ALL

DOORS AND DRAWERS

ADJUSTABLE SHELVES; SEMI

EXPOSED SURFACES TO BE

MELAMINE

DRAWER PER ELEVATIONS

COUNTER TOP MATERIAL

PER INTERIOR ELEVATIONS

WOOD BLOCKING AS NEEDED

WALL CABINETS IF APPLICABLE

TO PROJECT PER INTERIOR

ELEVATIONS

CONSTRUCTION SIMILAR

TO BASE CABINETS

CEILING PER PLANS AND

SCHEDULES

STUD WALL PER PLANS

WIDTH

PER PLANS

3-5/8" METAL STUD

RUNNER WRAPPED DOUBLE

METAL STUD; STUD TYPICAL

TO WALL THICKNESS

MINERAL WOOL INSULATION;

FULL FRAME WIDTH AND DEPTH

HOLLOW METAL DOOR FRAME;

SEE SPECIFICATIONS

5/8" GYPSUM BOARD PER

WALL TYPE SCHEDULE

WOOD OR HOLLOW METAL DOOR;

SEE SCHEDULES AND DETAILS

3-5/8" METAL STUD

DOUBLE METAL STUDS; SAME

AS WALL CONSTRUCTION

MINERAL WOOL INSULATION;

FULL FRAME WIDTH AND DEPTH

HOLLOW METAL DOOR FRAME;

SEE SPECIFICATIONS

5/8" GYPSUM BOARD PER

WALL TYPE SCHEDULE

WOOD OR HOLLOW METAL DOOR;

SEE SCHEDULES AND DETAILS

ANCHOR METAL STUD WALL

TO ACOUSTICAL CEILING TILE

SYSTEM

METAL STUD WALL; THICKNESS

PER PLANS

ACOUSTICAL CEILING SYSTEM;

SEE ROOM FINISH SCHEDULE

AND CEILING PLANS

PAINT WALL PER FINISH

SCHEDULES

(TYPICAL PER REMODEL AREA 01 ONLY)

LEVER STOREROOM LOCK

Outside lever fixed, unlocked by key. Inside lever always unlocked.

LEVER CLASSROOM LOCK

Outside lever locked and unlocked by key. Inside lever always unlocked.

SINGLE CYLINDER CLASSROOM LOCK

Deadbolt locked or unlocked by key from outside. Deadbolt unlocked by thumbturn only from inside.

LEVER OFFICE LOCK

Push-button locking. Pushing button locks outside lever until unlocked by key outside or by turning inside lever.

LEVER ENTRANCE LOCK

Turn/Push-button locking. Pushing and turning button locks outside lever requiring use of key until button in manually unlocked.

Push-button locking. Push button locks outside lever until locked by outside key or by turning inside lever.

DOOR WIDTH

D O

O R

H E

IG

H

T

DOOR WIDTH

D O

O R

H E

IG

H

T

F LNL

6"

1' -6

2'-0" 6"

7' -0

2"

3'-0"

7' -0

2"

3'-0" 1'-6"

A B

WALL BASE PER ROOM FINISH SCHEDULE

FLOOR FINISH PER SCHEDULES AND

DETAILS

CONTINUOUS STEEL STUD

RUNNER; ANCHOR TO FLOOR STRUCTURE

5/8" GYPSUM BOARD; BOTH SIDES

ACOUSTICAL BATT INSULATION; TYPICAL

AT ACOUSTICAL PARTITIONS

FINISH CEILING PER SCHEDULES AND

WALL SECTIONS

UNDERSIDE OF STRUCTURE

EXTEND TO UNDERSIDE OF STRUCTURE

AND SEAL PER SCHEDULES AND DETAILS

W A

LL

H

E

IG

H T

P E

R S

C H

E D

U

LE

S

WALL EXTENDED PAST FINISH CEILING;

SEE BRACING DETAIL

U UL RATED - BULLET RES.

U1 3-5/8" STEEL STUD; UL LEVEL III RATING / WALL TO STRUCTURE

BULLET RESISTANT FIBERGLASS PANEL;

UL RATING PER PLANS AND SPECS; PANEL

AT SECURE SIDE OF CONSTRUCTION

4" WIDE BATTEN STRIP AT EACH PANEL

SEAM; SEE SPECIFICATIONS

*ALL INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH

MANUFACTURER'S SPECIFICATIONS

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved SCALE: As indicated

A002Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Wall Types & Typical Details

912 56th St, Kenosha, WI 53140

3" = 1'-0"2 Typical Kicker Detail

3" = 1'-0"5 Typical Sound Stop

1/2" = 1'-0"6 Typical Millwork Section

3" = 1'-0"4 3-5/8" Metal Stud Head 3" = 1'-0"3 3-5/8" Metal Stud Jamb

3" = 1'-0"1 Partition Wall @ Ceiling

MATERIAL KEY

CODE DESCRIPTION

CEILING TYPE

ACT-1 2x2 Acoustical Ceiling Panels

FLOOR TYPE

CPT-1 2x2 Carpet Tile VB 4" Vinyl Base

PAINT SCHEDULE KEY

EPOXY Epoxy Paint LATEX-E Latex Wall Paint - Enamel LATEX-S Latex Wall Paint - Satin Finish

WALL TYPE

GL-1 3/8" Glass GL-2 1" Insulated Glass GL-3 Bullet Resisitant Glazing - Level III GWB1 5/8" G.W.B. Taped and Finished on Stud Framing per Wall Type GWB2 5/8" Moisture & Mold Resistant Gypsum Wallboard

Taped & Finished on Stud Framing per Wall Type

LOCKSET TYPESDOOR PANEL TYPES DOOR FRAME

2 2

CR

02 41 16.08 vestibule

E

E

E2

B

02 05 00.D1

02 05 00.J2 existing conference ex1101 existing conference

/office ex1102

02 41 16.16

E201C

02 41 16.17 02 41 16.18

02 41 16.19

02 41 16.19

02 41 16.1002 41 16.10

NO WORK IN THIS

AREA

02 41 16.22

02 41 16.22

02 41 16.22

02 41 16.22

02 41 16.22

02 41 16.22

02 41 16.01 vestibule conference existing conference ex1101

NO WORK IN THIS

AREA

1. REMOVE LOOSE PAINT AND

MISCELLANEOUS HANGING OBJECTS

FROM WALLS AND CEILINGS AT ALL

AREAS TO RECEIVE NEW FINISHES.

2. PATCH AND REPAIR ALL EXISTING

FLOOR SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION OR

PRIOR USE.

3. PATCH ALL AREAS OF ELECTRICAL

AND MECHANICAL DEMOLITION THAT

WILL NOT BE REUSED.

4. CONTRACTOR TO FIELD VERIFY ALL

EXISTING DIMENSIONS AND

CONDITIONS. IN THE EVENT OF A

DISCREPANCY BETWEEN THE

DRAWINGS AND THE EXISTING

CONDITIONS, NOTIFY THE ARCHITECT

BEFORE PROCEEDING.

5. DO NOT REMOVE ANY ITEMS WHICH

JEOPARDIZE THE STRUCTURAL

INTEGRITY OF THE BUILDING. IF

HIDDEN ELEMENTS OR DETERIORATED

ELEMENTS ARE ENCOUNTERED,

NOTIFY THE ARCHITECT IMMEDIATELY.

6. PROTECT ALL ADJACENT AREAS AND

ITEMS "TO REMAIN" DURING

DEMOLITION/CONSTRUCTION.

REPAIR/REPLACE ALL ITEMS DAMAGED

DURING CONSTRUCTION.

7. EXISTING BUILDING CONDITIONS

SHOWN ON THESE DRAWINGS ARE

DERIVED FROM DRAWINGS OF THE

ORIGINAL BUILDING AND FROM LIMITED

FIELD OBSERVATION.

8. THE CONTRACTOR SHALL PROVIDE

AND MAINTAIN ADDITIONAL MEANS OF

EGRESS AS NEEDED AS A RESULT OF

CONSTRUCTION SEQUENCING AND/OR

REGULATORY REQUIREMENTS.

GENERAL PROJECT NOTES

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: As indicated

1A200Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 01 - Existing and Demo

912 56th St, Kenosha, WI 53140

1/4" = 1'-0"1 Remodel Area 01 - Existing and Demo Plan

Spec. # Description

02 05 00.D1 EXISTING WINDOW TO REMAIN

02 05 00.J2 EXISTING CASEWORK TO REMAIN

02 41 16.01 DEMO EXISTING WALL; DEMO INCLUDES ALL WINDOWS,

DOORS AND ENTIRE WALL ASSEMBLY

02 41 16.08 DEMO EXISTING WINDOW; PATCH WALL AS NEEDED; PAINT

PER ROOM FINISH SCHEDULE

02 41 16.10 DEMO EXISTING CARPET; DEMO INCLUDES EXISTING WALL

BASE; PREP FLOOR AS NEEDED FOR NEW CARPET INSTALL

02 41 16.16 DEMO EXISTING OUTLET

02 41 16.17 RELOCATE LIGHT SWITCH LOCATION TO NEW WALL; SEE

ELECTRICAL PLANS FOR LOCATION

02 41 16.18 DEMO EXISTING LIGHT SWITCH

02 41 16.19 REMOVE EXISTING WAINSCOTTING IN ENTIRE ROOM; PATCH

AS NEEDED AND PAINT PER SCHEDULE

02 41 16.22 DEMO EXISTING LIGHT FIXTURE

1/4" = 1'-0"2 Area 01 - Ceiling Plan - Existing

1101A victim witness vestibule

4' -0

2' -2

1'

-5 conference

18'-1"

'-2

/8

7/

8"

E2101

3' -2

A1

A1

A1

2' -6

A1 02 05 00.F2

5' -1

5/

8"

2' -8

3' -2

10'-10"

1A201

02 05 00.D1

7' -1

0"

18'-1"

EXISTING 5/8" GYPSUM BOARD

TO REMAIN

(09 91 00) PAINT PER ROOM FINISH

SCHEDULE

(09 65 00) WALL BASE PER ROOM

FINISH SCHEDULE

EXISTING ACOUSTICAL CEILING

TILE TO REMAIN

RELOCATED LIGHT FIXTURE;

SEE CEILING PLANS

victim witness

7' -1

0"

11'-2 7/8" 2'-8" victim witness

EXISTING 5/8" GYPSUM BOARD

TO REMAIN

(09 91 00) PAINT PER ROOM FINISH

SCHEDULE

(09 65 00) WALL BASE PER ROOM

FINISH SCHEDULE

EXISTING ACOUSTICAL CEILING

TILE TO REMAIN

victim witness 11017'

-1 0"

10'-10"7'-3"

EXISTING 5/8" GYPSUM BOARD

TO REMAIN

(09 91 00) PAINT PER ROOM FINISH

SCHEDULE

(09 65 00) WALL BASE PER ROOM

FINISH SCHEDULE

EXISTING ACOUSTICAL CEILING

TILE TO REMAIN

2'-6" 7 7/8"

2'-2" 2'-1" 3'-4" 3'-2"

13'-10 7/8"

1101A

(08 14 29) WOOD DOOR; SOLID

CORE - SEE SPECIFICATIONS

(09 91 00) PAINT PER ROOM FINISH

SCHEDULE

(09 65 00) WALL BASE PER ROOM

FINISH SCHEDULE

EXISTING ACOUSTICAL CEILING

TILE TO REMAIN

1. REMOVE LOOSE PAINT AND

MISCELLANEOUS HANGING OBJECTS

FROM WALLS AND CEILINGS AT ALL

AREAS TO RECEIVE NEW FINISHES.

2. PATCH AND REPAIR ALL EXISTING

FLOOR SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION OR

PRIOR USE.

3. PATCH ALL AREAS OF ELECTRICAL

AND MECHANICAL DEMOLITION THAT

WILL NOT BE REUSED.

4. CONTRACTOR TO FIELD VERIFY ALL

EXISTING DIMENSIONS AND

CONDITIONS. IN THE EVENT OF A

DISCREPANCY BETWEEN THE

DRAWINGS AND THE EXISTING

CONDITIONS, NOTIFY THE ARCHITECT

BEFORE PROCEEDING.

5. DO NOT REMOVE ANY ITEMS WHICH

JEOPARDIZE THE STRUCTURAL

INTEGRITY OF THE BUILDING. IF

HIDDEN ELEMENTS OR DETERIORATED

ELEMENTS ARE ENCOUNTERED,

NOTIFY THE ARCHITECT IMMEDIATELY.

6. PROTECT ALL ADJACENT AREAS AND

ITEMS "TO REMAIN" DURING

DEMOLITION/CONSTRUCTION.

REPAIR/REPLACE ALL ITEMS DAMAGED

DURING CONSTRUCTION.

7. EXISTING BUILDING CONDITIONS

SHOWN ON THESE DRAWINGS ARE

DERIVED FROM DRAWINGS OF THE

ORIGINAL BUILDING AND FROM LIMITED

FIELD OBSERVATION.

8. THE CONTRACTOR SHALL PROVIDE

AND MAINTAIN ADDITIONAL MEANS OF

EGRESS AS NEEDED AS A RESULT OF

CONSTRUCTION SEQUENCING AND/OR

REGULATORY REQUIREMENTS.

GENERAL PROJECT NOTES

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: As indicated

1A201Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 01 - Plans and Details

912 56th St, Kenosha, WI 53140

1/4" = 1'-0"1 Remodel Area 01 - Proposed Plan

1/4" = 1'-0"4 Victim Witness 1101 - North

Spec. # Description

02 05 00.D1 EXISTING WINDOW TO REMAIN

02 05 00.F2 EXISTING DOOR AND FRAME TO REMAIN

DOOR SCHEDULE - AREA 01

MARK

FROM ROOM TO ROOM

LABEL

DOOR FRAME

REMARKSNUM NAME NUM NAME TYPE MATERIAL SWING WIDTH HEIGHT THICKNESS LOUVER GLASS TYPE MATERIAL GLASS 1101A 1100 vestibule 1101 victim witness - FG Wood LH 3' - 0" 7' - 0" 1 3/4" - X A HM - Contractor to provide door frame acceptable for new card reader and electric strike

HARDWARE SCHEDULE - AREA 01

MARK LOCKSET PUSH-PULL HOLD OPEN CLOSER HINGE DOOR STOP THRESHOLD WEATHERSTRIP KICKPLATE SOUNDSTOP NAMEPLATE NOTES 1101A By Owner - - X X - X - - X - Lockset Provided by Owner; Installed by Contractor

PAINT SCHEDULE - AREA 01

ROOM

FLOOR

WALLS

CEILING METAL WOOD REMARKSNUM NAME NORTH SOUTH EAST WEST

1100 vestibule - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 1101 victim witness - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 1102 conference - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish

ROOM SCHEDULE - AREA 01

NUMBER NAME FLOOR TYPE BASE

WALL FINISH CEILING

REMARKSNORTH SOUTH EAST WEST TYPE HEIGHT

1100 vestibule Carpet 4" VINYL Existing Existing GWB1/GL-1 Existing ACT-1 Existing 1101 victim witness Carpet 4" VINYL Existing GWB1 Existing Existing/GWB1/GL-1 ACT-1 Existing 1102 conference Carpet 4" VINYL Existing/GWB1 Existing Existing Existing/GWB1 Existing Existing

1/4" = 1'-0"3 Victim Witness 1101 - East 1/4" = 1'-0"2 Victim Witness 1101 - South

1/4" = 1'-0"5 Victim Witness 1101 - West

2'-8"

NO WORK IN THIS

AREA

09 29 00.09

2' -9

/8 vestibule victim witness conference

09 51 00.02

A002

Sim

09 51 00.02

26 05 00.0726 05 00.07

26 05 00.0726 05 00.07

26 05 00.07

26 05 00.07victim witness vestibule conference

02 41 16.21

02 41 16.21

2X2 CARPET TILE

FLOOR FINISH LEGEND

EXISTING FLOORING TO REMAIN

1101A victim witness vestibule conference

EXISTING

CONFERENCE ROOM

TABLE

EXISTING

BOOKSHELF

EXISTING

BOOKSHELF

*FURNITURE PLAN IS REFERENCE ONLY - ALL NEW FURNITURE BY OWNER

1. REMOVE LOOSE PAINT AND

MISCELLANEOUS HANGING OBJECTS

FROM WALLS AND CEILINGS AT ALL

AREAS TO RECEIVE NEW FINISHES.

2. PATCH AND REPAIR ALL EXISTING

FLOOR SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION OR

PRIOR USE.

3. PATCH ALL AREAS OF ELECTRICAL

AND MECHANICAL DEMOLITION THAT

WILL NOT BE REUSED.

4. CONTRACTOR TO FIELD VERIFY ALL

EXISTING DIMENSIONS AND

CONDITIONS. IN THE EVENT OF A

DISCREPANCY BETWEEN THE

DRAWINGS AND THE EXISTING

CONDITIONS, NOTIFY THE ARCHITECT

BEFORE PROCEEDING.

5. DO NOT REMOVE ANY ITEMS WHICH

JEOPARDIZE THE STRUCTURAL

INTEGRITY OF THE BUILDING. IF

HIDDEN ELEMENTS OR DETERIORATED

ELEMENTS ARE ENCOUNTERED,

NOTIFY THE ARCHITECT IMMEDIATELY.

6. PROTECT ALL ADJACENT AREAS AND

ITEMS "TO REMAIN" DURING

DEMOLITION/CONSTRUCTION.

REPAIR/REPLACE ALL ITEMS DAMAGED

DURING CONSTRUCTION.

7. EXISTING BUILDING CONDITIONS

SHOWN ON THESE DRAWINGS ARE

DERIVED FROM DRAWINGS OF THE

ORIGINAL BUILDING AND FROM LIMITED

FIELD OBSERVATION.

8. THE CONTRACTOR SHALL PROVIDE

AND MAINTAIN ADDITIONAL MEANS OF

EGRESS AS NEEDED AS A RESULT OF

CONSTRUCTION SEQUENCING AND/OR

REGULATORY REQUIREMENTS.

GENERAL PROJECT NOTES

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: As indicated

1A202Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 01 - Ceiling & Finish Plans

912 56th St, Kenosha, WI 53140

Spec. # Description

02 41 16.21 CUT EXISTING CARPET AT NEW WALL LINE

09 29 00.09 EXTEND HEADER; MATCH EXISTING HEIGHT OF F.F.; FIELD

VERIFY

09 51 00.02 ACOUSTICAL CEILING TILE; REPLACE AND REPAIR AS NEEDED

PER NEW LAYOUT

26 05 00.07 NEW 2X2 LIGHT FIXTURES;OWNER TO PROVIDE FIXTURE,

CONTRACTOR TO INSTALL

1/4" = 1'-0"1 Area 01 - Ceiling Plan - Proposed 1/4" = 1'-0"2 Remodel Area 01 - Floor Finish Plan

Remodel Area 01 - Furniture Plan (Reference

ONLY)

C R

C4

CR

C4

1101A victim witness vestibule conference

E2101

27 00 00.01

02 05 00.T1

26 05 00.06 electrical ex 19

FIELD VERIFY EXISTING

DATA RACK LOCATION:

COORDINATE WITH

COUNTY IT

27 00 00.03

26 05 00.01 kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: 1/4" = 1'-0"

1IT200Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 01 - Technology & Electrical Plan

912 56th St, Kenosha, WI 53140

Spec. # Description

02 05 00.T1 EXISTING CARD READER TO REMAIN

26 05 00.01 RELOCATE LIGHT SWITCH LOCATION; NEW LOCATION PER

PLAN

26 05 00.06 PROVIDE POWER AND DATA FOR TV LOCATION; CONFIRM

FINAL LOCATION WITH OWNER

27 00 00.01 NEW CARD READER; CONTRACTOR TO PROVIDE CABLE PULL

AND CARD READER ROUGH IN

27 00 00.03 ALL REMODEL AREA 01 NEW DATA LOCATIONS TO ROUTE

BACK TO EXISTING IT 2112; COORDINATE WITH COUNTY IT;

CONTRACTOR TO PROVIDE ALL DATA PULL

existing witness room ex101 existing

RR

ex102 existing room ex107 existing storage ex108 existing storage ex109 existing IT server room ex103 existing clst.

ex105 existing clst.

ex104 existing file storage room

02 41 16.01

9" 4

7'-3 1/2"

02 41 16.01

02 41 16.01

02 41 16.01

02 41 16.02

02 41 16.01

02 41 16.10

02 41 16.11

02 41 16.12

02 41 16.13

02 41 16.13

02 41 16.13 02 41 16.13

(NO WORK IN THIS AREA)

02 41 16.14

02 41 16.01

FIELD VERIFY

4'-5 1/2"

02 41 16.01 ex existing vestibule ex100 e103A

2'-2 1/2"7'-11"

2' -0

6'-6" 2'-10 1/2" 7'-5"

FI

E

LD

V

E R

IF

Y

6' -0

FI

E

LD

V

E R

IF

Y

7' -5

3'

-3

/2

6' -4

/1

6" 3'

-3

/2

7'-9 5/8" 8'-0"

2' -0

FI

E

LD

V

E R

IF

Y

'-2

3/

FI

E

LD

V

E R

IF

Y

'-8

/2

6'-1"

4'-4 3/4"

15'-5"

5' -8

/2

4'-7 1/2"

2'-2 1/4"

9' -6

2' -2

/4

3'

-1

3/

12'-2 3/8"

16'-7 1/8" existing clst. ex106

02 41 16.13

02 41 16.13

02 41 16.13

02 41 16.13

02 41 16.13 existing hallway

'-7

15'-5"

02 41 16.10

02 41 16.10

02 41 16.10

02 41 16.10

2A300

1. REMOVE LOOSE PAINT AND

MISCELLANEOUS HANGING OBJECTS

FROM WALLS AND CEILINGS AT ALL

AREAS TO RECEIVE NEW FINISHES.

2. PATCH AND REPAIR ALL EXISTING

FLOOR SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION OR

PRIOR USE.

3. PATCH ALL AREAS OF ELECTRICAL

AND MECHANICAL DEMOLITION THAT

WILL NOT BE REUSED.

4. CONTRACTOR TO FIELD VERIFY ALL

EXISTING DIMENSIONS AND

CONDITIONS. IN THE EVENT OF A

DISCREPANCY BETWEEN THE

DRAWINGS AND THE EXISTING

CONDITIONS, NOTIFY THE ARCHITECT

BEFORE PROCEEDING.

5. DO NOT REMOVE ANY ITEMS WHICH

JEOPARDIZE THE STRUCTURAL

INTEGRITY OF THE BUILDING. IF

HIDDEN ELEMENTS OR DETERIORATED

ELEMENTS ARE ENCOUNTERED,

NOTIFY THE ARCHITECT IMMEDIATELY.

6. PROTECT ALL ADJACENT AREAS AND

ITEMS "TO REMAIN" DURING

DEMOLITION/CONSTRUCTION.

REPAIR/REPLACE ALL ITEMS DAMAGED

DURING CONSTRUCTION.

7. EXISTING BUILDING CONDITIONS

SHOWN ON THESE DRAWINGS ARE

DERIVED FROM DRAWINGS OF THE

ORIGINAL BUILDING AND FROM LIMITED

FIELD OBSERVATION.

8. THE CONTRACTOR SHALL PROVIDE

AND MAINTAIN ADDITIONAL MEANS OF

EGRESS AS NEEDED AS A RESULT OF

CONSTRUCTION SEQUENCING AND/OR

REGULATORY REQUIREMENTS.

GENERAL PROJECT NOTES

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: As indicated

2A200Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 02 - Existing and Demo Plans

912 56th St, Kenosha, WI 53140

1/4" = 1'-0"1 Area 01 - Existing and Demo Plan

Spec. # Description

02 41 16.01 DEMO EXISTING WALL; DEMO INCLUDES ALL WINDOWS, DOORS

AND ENTIRE WALL ASSEMBLY

02 41 16.02 DEMO EXISTING WINDOW SYSTEM

02 41 16.10 DEMO EXISTING CARPET; DEMO INCLUDES EXISTING WALL BASE;

PREP FLOOR AS NEEDED FOR NEW CARPET INSTALL

02 41 16.11 DEMO EXISTING TILE FLOOR; DEMO INCLUDES EXISTING WALL

BASE; PREP FLOOR AS NEEDED FOR NEW TILE INSTALL

02 41 16.12 DEMO AND REPLACE CEILING TILE AND GRID AS NEEDED FOR

NEW WALLS; SEE NEW FLOOR PLAN SHEETS

02 41 16.13 REMOVE EXISTING WALL BASE; REPLACE PER ROOM FINISH

SCHEDULE; PAINT PER ROOM FINISH SCHEDULE

02 41 16.14 DEMO EXISTING COUNTER TOP AND SINK VANITY; DEMO

INCLUDES UPPER CABINETS

existing IT office conference waiting reception clst.

existing RR

ex. chase office 01 existing file storage room

7' -1

7/

8" 9'

-7

8' -1

5/ multi purpose office

FI

E

LD

V

E R

IF

Y

D

IM

E N

S

IO

N S

'-4

/1

6"

'-8

8'-9 1/2"

20'-0"

'-0

'-9

/8

'-1

7/

8"

'-9

7' -5 office 03

3' -3

/2

6'

-0

2A300 5

2A300

B

2101A

4"

2107A

2108A

2111A

2109A

2110A

'-1

'-6

E2103 clst.

A

2A300 7

02 05 00.C5 hall

7'-9 5/8" 8'-0"

15'-9 5/8"

14'-8 5/8"

6'-6 5/8"

9'-7"

2A300

4' -3

/8

2A300

1'-4"

2A3006

5' -3

/8

E2106

E2105

E2104

A1 A1

A1 A002

Sim

A002

Sim

B1

B1

B3

B3

B3

A1 A1

A1

A1

A1 existing hall

A1

A1

A1

A1

A1

2A3004

02 05 00.C6

2A300

1. REMOVE LOOSE PAINT AND

MISCELLANEOUS HANGING OBJECTS

FROM WALLS AND CEILINGS AT ALL

AREAS TO RECEIVE NEW FINISHES.

2. PATCH AND REPAIR ALL EXISTING

FLOOR SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION OR

PRIOR USE.

3. PATCH ALL AREAS OF ELECTRICAL

AND MECHANICAL DEMOLITION THAT

WILL NOT BE REUSED.

4. CONTRACTOR TO FIELD VERIFY ALL

EXISTING DIMENSIONS AND

CONDITIONS. IN THE EVENT OF A

DISCREPANCY BETWEEN THE

DRAWINGS AND THE EXISTING

CONDITIONS, NOTIFY THE ARCHITECT

BEFORE PROCEEDING.

5. DO NOT REMOVE ANY ITEMS WHICH

JEOPARDIZE THE STRUCTURAL

INTEGRITY OF THE BUILDING. IF

HIDDEN ELEMENTS OR DETERIORATED

ELEMENTS ARE ENCOUNTERED,

NOTIFY THE ARCHITECT IMMEDIATELY.

6. PROTECT ALL ADJACENT AREAS AND

ITEMS "TO REMAIN" DURING

DEMOLITION/CONSTRUCTION.

REPAIR/REPLACE ALL ITEMS DAMAGED

DURING CONSTRUCTION.

7. EXISTING BUILDING CONDITIONS

SHOWN ON THESE DRAWINGS ARE

DERIVED FROM DRAWINGS OF THE

ORIGINAL BUILDING AND FROM LIMITED

FIELD OBSERVATION.

8. THE CONTRACTOR SHALL PROVIDE

AND MAINTAIN ADDITIONAL MEANS OF

EGRESS AS NEEDED AS A RESULT OF

CONSTRUCTION SEQUENCING AND/OR

REGULATORY REQUIREMENTS.

GENERAL PROJECT NOTES

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: As indicated

2A201Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 02 - Proposed Floor Plan

912 56th St, Kenosha, WI 53140

Spec. # Description

02 05 00.C5 EXISTING CONCRETE COLUMN TO REMAIN; FIELD VERIFY

LOCATION

02 05 00.C6 EXISTING STEEL COLUMN TO REMAIN; PAINT PER ROOM

FINISH SCHEDULE

ROOM SCHEDULE - AREA 02

NUMBER NAME FLOOR TYPE BASE

WALL FINISH CEILING

REMARKSNORTH SOUTH EAST WEST TYPE HEIGHT

2100 waiting CPT-1 TL-1 GWB1 Existing Existing GWB1/GL-3 ACT-1 7'-11" 2101 reception CPT-1 VB Existing Existing GWB1/GL-3 Existing ACT-1 7'-11" 2102 hall CPT-1 VB Existing GWB1 Existing/GWB1 Existing/GWB1 ACT-1 7'-11" 2103 existing RR Existing Existing Existing Existing Existing Existing ACT-1 Existing 2104 ex. chase Existing Existing Existing Existing Existing Existing Existing Existing 2105 clst. CPT-1 Existing Existing Existing Existing Existing Existing Existing 2106 clst. CPT-1 Existing Existing Existing Existing Existing Existing Existing 2107 office 01 CPT-1 VB GWB1 Existing/GWB1 Existing GWB1/GL-1 ACT-1 7'-11" 2108 multi purpose office 02 CPT-1 VB GWB1 GWB1 Existing/GWB1 GWB1/GL-1 ACT-1 7'-11" 2109 office 03 CPT-1 VB Existing/GWB1 GWB1 Existing/GWB1 GWB1/GL-1 ACT-1 7'-11" 2110 office CPT-1 VB Existing/GWB1 GWB1 Existing/GWB1 Existing ACT-1 7'-11" 2111 conference CPT-1 VB GWB1 Existing/GWB1 GWB1/GL-1 Existing/GWB1 ACT-1 7'-11" 2112 existing IT Existing Existing Existing Existing Existing Existing Existing Existing

DOOR SCHEDULE - AREA 02

MARK

FROM ROOM TO ROOM

LABEL

DOOR FRAME

REMARKSNUM NAME NUM NAME TYPE MATERIAL SWING WIDTH HEIGHT THICKNESS LOUVER GLASS TYPE MATERIAL GLASS 2100A - existing hall 2100 waiting - HG Wood RH 3' - 0" 7' - 0" 1 3/4" - X A HM - - 2100B 2100 waiting 2102 hall - HG Wood LHR 3' - 0" 7' - 0" 1 3/4" - X A HM - Contractor to provide door frame acceptable for new card reader and electric strike 2101A 2102 hall 2101 reception - LNL Wood RH 3' - 0" 7' - 0" 1 3/4" - X A HM - - 2107A 2102 hall 2107 office 01 - LNL Wood LH 3' - 0" 7' - 0" 1 3/4" - X A HM - - 2108A 2102 hall 2108 multi purpose office 02 - LNL Wood RH 3' - 0" 7' - 0" 1 3/4" - X A HM - - 2109A 2102 hall 2109 office 03 - LNL Wood RH 3' - 0" 7' - 0" 1 3/4" - X A HM - - 2110A 2102 hall 2110 office - LNL Wood LH 3' - 0" 7' - 0" 1 3/4" - X A HM - - 2111A 2102 hall 2111 conference - LNL Wood LH 3' - 0" 7' - 0" 1 3/4" - X A HM - -

HARDWARE SCHEDULE

MARK LOCKSET PUSH-PULL HOLD OPEN CLOSER HINGE DOOR STOP THRESHOLD WEATHERSTRIP KICKPLATE SOUNDSTOP NAMEPLATE NOTES 2100A By Owner - - X X - X - - X - Lockset Provided by Owner; Installed by G.C.

2100B By Owner - - X X X - - - X - Lockset Provided by Owner; Installed by G.C.

2101A By Owner - - X X X - - - X - Lockset Provided by Owner; Installed by G.C.

2107A By Owner - - - X X - - - X - Lockset Provided by Owner; Installed by G.C.

2108A By Owner - - - X X - - - X - Lockset Provided by Owner; Installed by G.C.

2109A By Owner - - - X X - - - X - Lockset Provided by Owner; Installed by G.C.

2110A By Owner - - - X X - - - X - Lockset Provided by Owner; Installed by G.C.

2111A By Owner - - - X X - - - X - Lockset Provided by Owner; Installed by G.C.

PAINT SCHEDULE

ROOM

FLOOR

WALLS

CEILING METAL WOOD REMARKSNUM NAME NORTH SOUTH EAST WEST

2100 waiting - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 2101 reception - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 2102 hall - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 2103 existing RR - - - - - - - - 2104 ex. chase - - - - - - - - 2105 clst. - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 2106 clst. - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 2107 office 01 - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 2108 multi purpose office 02 - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 2109 office 03 - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 2110 office - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 2111 conference - Latex-S Latex-S Latex-S Latex-S - Enamel Varnish 2112 existing IT - - - - - - - -office conference waiting 2100reception clst.

existing RR hall

ex. chase office 01 existing file storage room multi purpose office office 03 clst.

02 05 00.C5 hall

6X8

CUBICLE 01

copy/print machine by owner

6X8

CUBICLE 02

5'-6" X 6'-0"

L SHAPED DESK

5'-6" X 6'-0"

L SHAPED DESK

5'-0" TABLE

5'-6" X 8'-0" X 8'-0"

U SHAPED DESK

4'-0" X 10'-0"

CONFERENCE TABLE

5'-6" X 6'-0"

L SHAPED DESK

existing IT office conference waiting reception clst.

existing RR

ex. chase office 01 existing file storage room multi purpose office office 03 clst.

hall

2X2 CARPET TILE

FLOOR FINISH LEGEND

EXISTING FLOORING TO REMAIN

1. REMOVE LOOSE PAINT AND

MISCELLANEOUS HANGING OBJECTS

FROM WALLS AND CEILINGS AT ALL

AREAS TO RECEIVE NEW FINISHES.

2. PATCH AND REPAIR ALL EXISTING

FLOOR SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION OR

PRIOR USE.

3. PATCH ALL AREAS OF ELECTRICAL

AND MECHANICAL DEMOLITION THAT

WILL NOT BE REUSED.

4. CONTRACTOR TO FIELD VERIFY ALL

EXISTING DIMENSIONS AND

CONDITIONS. IN THE EVENT OF A

DISCREPANCY BETWEEN THE

DRAWINGS AND THE EXISTING

CONDITIONS, NOTIFY THE ARCHITECT

BEFORE PROCEEDING.

5. DO NOT REMOVE ANY ITEMS WHICH

JEOPARDIZE THE STRUCTURAL

INTEGRITY OF THE BUILDING. IF

HIDDEN ELEMENTS OR DETERIORATED

ELEMENTS ARE ENCOUNTERED,

NOTIFY THE ARCHITECT IMMEDIATELY.

6. PROTECT ALL ADJACENT AREAS AND

ITEMS "TO REMAIN" DURING

DEMOLITION/CONSTRUCTION.

REPAIR/REPLACE ALL ITEMS DAMAGED

DURING CONSTRUCTION.

7. EXISTING BUILDING CONDITIONS

SHOWN ON THESE DRAWINGS ARE

DERIVED FROM DRAWINGS OF THE

ORIGINAL BUILDING AND FROM LIMITED

FIELD OBSERVATION.

8. THE CONTRACTOR SHALL PROVIDE

AND MAINTAIN ADDITIONAL MEANS OF

EGRESS AS NEEDED AS A RESULT OF

CONSTRUCTION SEQUENCING AND/OR

REGULATORY REQUIREMENTS.

GENERAL PROJECT NOTES

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

SCALE: As indicated

2A202Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 02 - Finish Plans

912 56th St, Kenosha, WI 53140

1/4" = 1'-0"2 Area 02 - Furniture Plan (Reference ONLY) 1/4" = 1'-0"1 Area 02 - Floor Finish Plan

KC Basement 0'-0" reception waiting

2'-0" 1'-0"1' -3

/2

2'

-1 0"

3' -8

/2

FI

E

LD

V

E R

IF

Y

E X

IS

TI

N G

S

TR

U C

TU

R

E

'-1

/8

(07 21 00) BATT INSULATION

(06 61 00) COUNTER TOP

SUPPORT BRACKET

(09 91 00) PAINT PER ROOM

FINISH SCHEDULE

(09 65 00) 4" VINYL WALL BASE;

SEE SPECIFICATIONS

(09 29 00) ANCHOR METAL STUD

WALL TO EXISTING FLOOR

(06 61 00) SOLID SURFACE

COUNTER TOP

(08 11 00) HOLLOW METAL

WINDOW FRAME W/ (08 80 00)

1/4" TEMPERED GLASS

(09 51 00) ACOUSTICAL CEILING

SYSTEM; SEE SPECIFICATIONS

(09 29 00) 3-5/8" METAL STUDS

@ 16" O.C.

(09 29 00) 3-5/8" METAL STUD

HEADER AT NEW RECEPTION

WINDOW

EXISTING STRUCTURE

A002

Sim

KC Basement 0'-0"

1'-10" 3'-4" 8" 3'-4"2'-2 1/4"2'-4"3'-10" 3'-4"

7' -2

2109A 2108A 2107A

9'-6" 5'-10"

7' -1

0"

(09 29 00) 5/8" GYPSUM BOARD;

PAINT PER FINISH SCHEDULE

(09 65 00) WALL BASE PER

ROOM FINISH SCHEDULE

(09 51 00) ACOUSTICAL CEILING

SYSTEM; SEE SPECIFICATIONS

(08 14 29) WOOD DOOR; SOLID

CORE; SEE SPECIFICATIONS

hall

KC Basement 0'-0"

10'-8 7/16" 4" 3'-4"3'-4" 4'-10"4'-1 7/16"

7' -1

0" 11'-5 7/8" 8'-6"

08 11 00.02 hall

2111A 2110A

7' -2

(09 29 00) 5/8" GYPSUM BOARD;

PAINT PER FINISH SCHEDULE

(09 65 00) WALL BASE PER

ROOM FINISH SCHEDULE

(09 51 00) ACOUSTICAL CEILING

SYSTEM; SEE SPECIFICATIONS

(08 14 29) WOOD DOOR; SOLID

CORE; SEE SPECIFICATIONS

KC Basement 0'-0"

2A300

7' -1

0"

2' -1

0"

4'-0"

4' -0

EXISTING ACOUSTICAL

CEILING SYTEM; SEE FINISH

PLANS AND DETAILS

(08 11 00) HOLLOW METAL

WINDOW FRAME W/ (08 80 00)

1/4" CLEAR TEMPERED GLASS

(06 61 00) SOLID SURFACE COUNTER

TOP; SEE SPECIFICATIONS

(09 29 00) 5/8" GYPSUM BOARD;

PAINT PER FINISH SCHEDULE

(09 65 00) WALL BASE PER

ROOM FINISH SCHEDULE

(06 40 00) COUNTER SUPPORT

WALL BRACKET

(08 80 00) VOICE PORT; SEE

SPECIFICATIONS

(08 80 00) PASS THRU TRAY OPEN

SECTION OF WINDOW

2A300

Sim

2A300

KC Basement 0'-0"

FI

E

LD

V

E R

IF

Y

E X

IS

TI

N G

C E

IL

IN

G H

E

IG

H T

7' -1

0"8' -1

0"

1' -0

FI

E

LD

V

E R

IF

Y

E X

IS

TI

N G

F

LO

O R

S

TR

U C

TU

R

E H

E

IG

H T

'-1

/8

A002

Sim

(09 29 00) BRACE METAL STUD

WALL TO EXISTING FLOOR

STRUCTURE

(09 51 00) ACOUSTICAL CEILING

SYSTEM; SEE ROOM FINISH

SCHEDULES AND CEILING

PLAN

(07 21 00) BATT INSULATION

(09 29 00) 3-5/8" METAL STUDS

@ 16" O.C.

(09 91 00) PAINT PER ROOM

FINISH SCHEDULE

(09 65 00) 4" VINYL WALL BASE;

SEE SPECIFICATIONS

(09 29 00) ANCHOR METAL STUD

WALL TO EXISTING FLOOR

KC Basement 0'-0"

4' -0 reception

(07 21 00) BATT INSULATION

(09 29 00) 3-5/8" METAL STUDS

@ 16" O.C.

(09 91 00) PAINT PER ROOM

FINISH SCHEDULE

(09 65 00) 4" VINYL WALL BASE;

SEE SPECIFICATIONS

(09 29 00) ANCHOR METAL STUD

WALL TO EXISTING FLOOR

(06 61 00) SOLID SURFACE

WALL CAP5 7/8"

1/

2"

KC Basement 0'-0"

5'-3 5/8"

7' -1

0"

UNDER

COUNETR

FRIDGE

BY OWNER

A002

Sim

2'-10"

1' -8

1'

-4

2' -0

2'

-1 0"

3' -0

(06 10 00) PROVIDE ALL REQUIRED

BLOCKING FOR ACCESSORIES;

GRAB BARS, CABINETS AND

MECHANICAL FIXTURES

(09 51 00) ACOUSTICAL CEILING

SYSTEM; SEE SPECIFICATIONS

(06 10 00) UPPER CABINET W/ OPEN

MICROWAVE SHELF; SIZE PER

PLANS AND ELEVATIONS

(06 10 00) UPPER CABINET; SIZE

PER ELEVATIONS AND DETAILS

(06 61 00) SOLID SURFACE COUNTER

TOP; SEE SPECIFICATIONS

SINK FAUCET; PROVIDED BY

OWNER - INSTALLED BY G.C.

(06 40 00) BASE CABINET;

SIZE PER ELEVATIONS AND

DETAILS

(09 29 00) 5/8" GYPSUM BOARD

FINISH; (09 91 00) PAINT PER ROOM

FINISH SCHEDULE

MICROWAVE

BY OWNER

KC Basement 0'-0"

2A300 waiting

(09 51 00) ACOUSTICAL

CEILING SYTEM; SEE FINISH

PLANS AND DETAILS

(08 11 00) HOLLOW METAL

WINDOW FRAME W/ (08 80 00)

1/4" CLEAR TEMPERED GLASS

(06 61 00) SOLID SURFACE COUNTER

TOP; SEE SPECIFICATIONS

(09 29 00) 5/8" GYPSUM BOARD;

PAINT PER FINISH SCHEDULE

(09 65 00) WALL BASE PER

ROOM FINISH SCHEDULE

(06 40 00) COUNTER SUPPORT

WALL BRACKET

(08 80 00) VOICE PORT; SEE

SPECIFICATIONS

(08 80 00) PASS THRU TRAY OPEN

SECTION OF WINDOW

3' -6

2' -1

0"

4'-3 5/8" 4'-0"

7' -1

0"

4' -4

EXISTING WALL TO REMAIN

2A300

KC Basement 0'-0"

(07 21 00) BATT INSULATION

(06 61 00) COUNTER TOP

SUPPORT BRACKET

(09 91 00) PAINT PER ROOM

FINISH SCHEDULE

(09 65 00) 4" VINYL WALL BASE;

SEE SPECIFICATIONS

(06 61 00) SOLID SURFACE

COUNTER TOP

(08 11 00) HOLLOW METAL

WINDOW FRAME W/ (08 80 00)

1/4" TEMPERED GLASS

(09 51 00) ACOUSTICAL CEILING

SYSTEM; SEE SPECIFICATIONS

(09 29 00) 3-5/8" METAL STUDS

@ 16" O.C.

(09 29 00) 8"X 1-5/8" 20 GA. BOX

HEADER AT NEW RECEPTION

WINDOW

EXISTING STRUCTURE

(06 61 00) SOLID SURFACE

COUNTER TOP

(06 61 00) SOLID SURFACE

WALL CAP

reception waiting

8" 2'

-1 0"

4' -1

/2

7' -1

0"

3' -8

/2

A002

Sim kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved SCALE: As indicated

2A300Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 02 - Sections and Details

912 56th St, Kenosha, WI 53140

3/4" = 1'-0"1 Reception Counter - Wall Section ADA

3/8" = 1'-0"7 Hall 1103 - East

3/8" = 1'-0"3 Hall 1103 - West 3/8" = 1'-0"5 Reception 1102 - East

1/2" = 1'-0"9 Typical 3-5/8" Stud Wall 3/4" = 1'-0"8 Reception Half Wall Section

3/8" = 1'-0"6 Hall 1103 - Kitchenette Area

3/8" = 1'-0"4 Waiting 2100 - West

3/4" = 1'-0"2 Reception Counter - Wall Section

02 41 16.15

02 41 16.15

02 41 16.15 02 41 16.15

02 41 16.15 existing witness room ex101 existing RR ex102 existing room ex107 existing storage ex108 existing storage ex109 existing IT server room ex103 existing clst.

ex105 existing clst.

ex104 existing file storage room existing vestibule ex100 existing clst. ex106

2A300 existing IT

(NO WORK IN THIS AREA)

reception

02 05 00.N1

02 05 00.N1

02 05 00.G1

02 05 00.L1

02 05 00.L1

02 05 00.N2

02 05 00.N2 waiting hall clst.

clst.

existing RR

ex. chase conference office office 03 multi purpose office office 01 existing file storage room

(NO WORK IN THIS AREA)

3A300

2A300

EXISTING CEILING SCHEDULE

DESCRIPTION EXISTING TOTAL

EXISTING 2X4 TROFFER LIGHT FIXTURE

RELOCATED

(PER PLAN) DEMOLISHED

EXISTING 2X2 TROFFER LIGHT FIXTURE

EXISTING 6" RECESSED CAN

26 EA.

EXISTING TO

REMAIN

10 EA. 12 EA. 4 EA.

2 EA. 0 EA. 0 EA. 2 EA.

ALTERNATE #1 - UPGRADE ALL LIGHT FIXTURES TO LED; OWNER TO PROVIDE FIXTURES -

G.C. TO INSTALL

2 EA. 0 EA. 0 EA. 2 EA.

26 51 00.01

1. REMOVE LOOSE PAINT AND

MISCELLANEOUS HANGING OBJECTS

FROM WALLS AND CEILINGS AT ALL

AREAS TO RECEIVE NEW FINISHES.

2. PATCH AND REPAIR ALL EXISTING

FLOOR SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION OR

PRIOR USE.

3. PATCH ALL AREAS OF ELECTRICAL

AND MECHANICAL DEMOLITION THAT

WILL NOT BE REUSED.

4. CONTRACTOR TO FIELD VERIFY ALL

EXISTING DIMENSIONS AND

CONDITIONS. IN THE EVENT OF A

DISCREPANCY BETWEEN THE

DRAWINGS AND THE EXISTING

CONDITIONS, NOTIFY THE ARCHITECT

BEFORE PROCEEDING.

5. DO NOT REMOVE ANY ITEMS WHICH

JEOPARDIZE THE STRUCTURAL

INTEGRITY OF THE BUILDING. IF

HIDDEN ELEMENTS OR DETERIORATED

ELEMENTS ARE ENCOUNTERED,

NOTIFY THE ARCHITECT IMMEDIATELY.

6. PROTECT ALL ADJACENT AREAS AND

ITEMS "TO REMAIN" DURING

DEMOLITION/CONSTRUCTION.

REPAIR/REPLACE ALL ITEMS DAMAGED

DURING CONSTRUCTION.

7. EXISTING BUILDING CONDITIONS

SHOWN ON THESE DRAWINGS ARE

DERIVED FROM DRAWINGS OF THE

ORIGINAL BUILDING AND FROM LIMITED

FIELD OBSERVATION.

8. THE CONTRACTOR SHALL PROVIDE

AND MAINTAIN ADDITIONAL MEANS OF

EGRESS AS NEEDED AS A RESULT OF

CONSTRUCTION SEQUENCING AND/OR

REGULATORY REQUIREMENTS.

GENERAL PROJECT NOTES

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: As indicated

2A400Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 02 - Ceiling Plans

912 56th St, Kenosha, WI 53140

1/8" = 1'-0"2 Area 02 - Ceiling Plan - Existing & Demo

Spec. # Description

02 05 00.G1 EXISTING CEILING TILE & GRID TO REMAIN; REPLACE CEILING

TILES AS NEEDED -FIELD VERIFY

02 05 00.L1 RELOCATE EXISTING REMOVED LIGHTING FIXTURE TO NEW

LOCATION

02 05 00.N1 EXISTING MECHANICAL EQUIPMENT TO REMAIN

02 05 00.N2 RELOCATE DEMOLISHED HVAC SUPPLY UNIT

02 41 16.15 DEMO EXISTING AREA OF ACT CEILING TILE

26 51 00.01 ALTERNATE #1 - UPGRADE ALL LIGHT FIXTURES TO LED

LIGHTING; SEE SPECIFICATIONS

1/4" = 1'-0"1 Area 02 - Ceiling Plan - Proposed

1/8" = 1'-0"3 Area 02 - Ceiling Plan - Alternate #1

C4

C4

C4

C4

C

CR

existing IT office conference waiting reception clst.

existing RR

ex. chase office 01 existing file storage room multi purpose office office 03 clst.

hall

26 05 00.01

DEDICATED

20A

26 05 00.0326 05 00.03

26 05 00.0326 05 00.03

3'-4" A.F.F

MICROWAVE

FRIDGE

26 05 00.05

C2

C

C

C

27 00 00.01

27 00 00.02

3'-4" A.F.F

26 05 00.08 kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: 1/4" = 1'-0"

2IT200Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 02 - Technology & Electrical Plans

912 56th St, Kenosha, WI 53140

Spec. # Description

26 05 00.01 RELOCATE LIGHT SWITCH LOCATION; NEW LOCATION PER

PLAN

26 05 00.03 FIELD VERIFY EXISTING OUTLET LOCATIONS; MINIMUM (01)

OUTLETS REQUIRED IN ADDITION TO OUTLET LOCATIONS

SHOWN ON PLAN; BASED ON EXISTING CONDITIONS

COORDINATE LOCATION WITH OWNER

26 05 00.05 EXISTING ELECTRICAL PANEL

26 05 00.08 NEW CIRCUITS FOR AREA 02 TO EXISTING ELECTRICAL PANEL;

COORDINATE CIRCUIT AVAILABILITY WITH COUNTY

27 00 00.01 NEW CARD READER; CONTRACTOR TO PROVIDE CABLE PULL

AND CARD READER ROUGH IN

27 00 00.02 ALL REMODEL AREA 02 NEW DATA LOCATIONS TO ROUTE

BACK TO EXISTING IT 2112; COORDINATE WITH COUNTY IT;

CONTRACTOR TO PROVIDE ALL DATA PULL

reception 2101 waiting hall clst.

clst.

existing RR

ex. chase conference office office 03 multi purpose office office 01 existing file storage room

(NO WORK IN THIS AREA)

FB-1

(EXISTING)

16X10

6" DIAM.

8" DIAM.

FB-2

(EXISTING)

6" DIAM.

8" DIAM.

8" DIAM.

T2

X

E

X

IS

TI

N

G

8" DIAM.

T1

8" DIAM.

RA

RA

RA

FB-3

(EXISTING)

FB-4

(EXISTING)

20X10

8" DIAM.

6" DIAM.

RA

RA

RA

6" DIAM.

RA

6" DIAM.

T3

X

N

E W

X

E

X

IS

TI

N

G

X

N E

W

X

E

X

IS

TI

N

G

X

N E

W

23 05 00.01

23 05 00.01

23 05 00.01 existing witness room ex101 existing

RR

ex102 existing room ex107 existing storage ex108 existing storage ex109 existing IT server room ex103 existing clst.

ex105 existing clst.

ex104 existing file storage room

(NO WORK IN THIS AREA)

existing vestibule ex100 existing clst. ex106

FB-1

(EXISTING)

16X10

FB-2

(EXISTING)

X

FB-3

(EXISTING)

FB-4

(EXISTING)

20X10

8" DIAM.

8" DIAM.

DEMO PORTION OF

8" DIAMETER FLEX DUCT

X

8" DIAM. 8" DIAM.

8" DIAM.

DEMO PORTION OF

8" DIAMETER FLEX

DUCT

8" DIAM.

8" DIAM.

1. ALL DUCTWORK IS DIAGRAMMATIC

AND COORDINATEDTO THE BEST

AVAILABLE INFORMATION.

CONTRACTOR SHALL VERIFY

STRUCTURE AND LOCATION OF OTHER

TRADES PRIOR TO FABRICATION

2. LIMIT FIXTURE RUNS TO A MAXIMUM OF

5'-0" AND ROUTE AS STRAIGHT AS

POSSIBLE.

3. SYSTEM SHALL BE BALANCED BY THE

INSTALLING CONTRACTOR. BALANCE

AIR FLOWS FOR GRILLES AND

EQUIPMENT TO +/- 10% OF SCHEDULED

AIRFLOWS. INCLUDE SYSTEM

MANUFACTURER, MODEL, SERIAL

NUMBER, RPM, HORSEPOWER,

VOLTAGE, AMPERAGE, ETC. IN

REPORTS. SUBMIT THE BALANCING

REPORTS TO THE DESIGN

PROFESSIONAL BEFORE A

COMPLIANCE STATEMENT CAN BE

SUBMITTED.

4. MECHANICAL LOW VOLTAGE WIRING

SHALL BE BY THE HVAC CONTRACTOR.

5. COORDINATE DIFFUSER LAYOUT WITH

LIGHTING LAYOUT.

6. THE CONTRACTOR SHALL PROVIDE

THE OWNER WITH WRITTEN

INSTRUCTION FOR THE OPERATION

AND MAINTENANCE OF THE SYSTEM

AND EQUIPMENT.

7. THERMOSTAT LOCATIONS SHALL BE

REVIEWED BY THE OWNER, TENANT

AND CONTRACTOR BEFORE

INSTALLATION. CONTROLS SHALL BE

LOCATED 48" ABOVE FINISH FLOOR

GENERAL MECHANICAL NOTES

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: As indicated

2M200Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 02 - HVAC Plan

912 56th St, Kenosha, WI 53140

1/4" = 1'-0"1 Area 02 - HVAC Plan - Proposed 1/4" = 1'-0"2 Area 02 - HVAC Plan - Existing

Spec. # Description

23 05 00.01 NEW THERMOSTAT LOCATION; COORDINATE WITH OWNER

02 41 16.01

02 41 16.02

02 41 16.09

02 41 16.09

02 41 16.01 existing reception existing waiting existing conference

3'-0"

02 41 16.1002 41 16.10

02 41 16.1102 41 16.10

02 41 16.1002 41 16.10

02 41 16.01

02 41 16.07

02 41 16.10 existing stair existing office existing office existing office existing storage existing office existing electrical existing hall existing vestibule existing vestibule existing office existing reception

8' -2

/2

1'

-8

1/

2" 1'

-1

1/ 2"

6' -1

1/

4" 2'

-2

2' -2

2'

-2

2' -2

1/

2"

4' -0

02 41 16.2302 41 16.23

02 41 16.20

02 41 16.01

02 41 16.01

02 41 16.01

02 41 16.10

02 41 16.10

02 41 16.01

EXISTING CEILING

TO REMAIN

EXISTING CEILING

TO REMAIN

02 41 16.15

02 05 00.L1 02 05 00.L1 02 05 00.L1

02 05 00.L1

02 05 00.L1

02 05 00.L1

02 05 00.L1

02 05 00.L1

02 41 16.2202 05 00.L1

02 05 00.L1

02 05 00.L1

02 05 00.L1 02 41 16.15

02 41 16.15

02 41 16.15

02 41 16.15

02 05 00.N2 02 05 00.N2

02 05 00.N2

EXISTING CEILING SCHEDULE - REMODEL AREA 03

DESCRIPTION EXISTING TOTAL

EXISTING 2X4 TROFFER LIGHT FIXTURE

RELOCATED

(PER PLAN) DEMOLISHED

EXISTING 2X2 TROFFER LIGHT FIXTURE

41 EA.

EXISTING TO

REMAIN

31 EA. 10 EA. 0 EA.

4 EA. 0 EA. 3 EA. 1 EA.

ALTERNATE #2 - UPGRADE ALL LIGHT FIXTURES TO LED - COUNTY TO PURCHASE

LIGHT FIXTURES - G.C. TO INSTALL

1. REMOVE LOOSE PAINT AND

MISCELLANEOUS HANGING OBJECTS

FROM WALLS AND CEILINGS AT ALL

AREAS TO RECEIVE NEW FINISHES.

2. PATCH AND REPAIR ALL EXISTING

FLOOR SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION OR

PRIOR USE.

3. PATCH ALL AREAS OF ELECTRICAL

AND MECHANICAL DEMOLITION THAT

WILL NOT BE REUSED.

4. CONTRACTOR TO FIELD VERIFY ALL

EXISTING DIMENSIONS AND

CONDITIONS. IN THE EVENT OF A

DISCREPANCY BETWEEN THE

DRAWINGS AND THE EXISTING

CONDITIONS, NOTIFY THE ARCHITECT

BEFORE PROCEEDING.

5. DO NOT REMOVE ANY ITEMS WHICH

JEOPARDIZE THE STRUCTURAL

INTEGRITY OF THE BUILDING. IF

HIDDEN ELEMENTS OR DETERIORATED

ELEMENTS ARE ENCOUNTERED,

NOTIFY THE ARCHITECT IMMEDIATELY.

6. PROTECT ALL ADJACENT AREAS AND

ITEMS "TO REMAIN" DURING

DEMOLITION/CONSTRUCTION.

REPAIR/REPLACE ALL ITEMS DAMAGED

DURING CONSTRUCTION.

7. EXISTING BUILDING CONDITIONS

SHOWN ON THESE DRAWINGS ARE

DERIVED FROM DRAWINGS OF THE

ORIGINAL BUILDING AND FROM LIMITED

FIELD OBSERVATION.

8. THE CONTRACTOR SHALL PROVIDE

AND MAINTAIN ADDITIONAL MEANS OF

EGRESS AS NEEDED AS A RESULT OF

CONSTRUCTION SEQUENCING AND/OR

REGULATORY REQUIREMENTS.

GENERAL PROJECT NOTES

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: As indicated

3A200Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 03 - Existing and Demo Plan

912 56th St, Kenosha, WI 53140

3/16" = 1'-0"1 Area 03 - Existing and Demo Plan

Spec. # Description

02 05 00.L1 RELOCATE EXISTING REMOVED LIGHTING FIXTURE TO NEW

LOCATION

02 05 00.N2 RELOCATE DEMOLISHED HVAC SUPPLY UNIT

02 41 16.01 DEMO EXISTING WALL; DEMO INCLUDES ALL WINDOWS,

DOORS AND ENTIRE WALL ASSEMBLY

02 41 16.02 DEMO EXISTING WINDOW SYSTEM

02 41 16.07 DEMO DOOR; PATCH WALL AS NEEDED; PAINT PER ROOM

FINISH SCHEDULE

02 41 16.09 DEMO COUNTER TOP

02 41 16.10 DEMO EXISTING CARPET; DEMO INCLUDES EXISTING WALL

BASE; PREP FLOOR AS NEEDED FOR NEW CARPET INSTALL

02 41 16.11 DEMO EXISTING TILE FLOOR; DEMO INCLUDES EXISTING WALL

BASE; PREP FLOOR AS NEEDED FOR NEW TILE INSTALL

02 41 16.15 DEMO EXISTING AREA OF ACT CEILING TILE

02 41 16.20 DEMO EXISTING KITCHENETTE AREA; DEMO INCLUDES BASE

CABINETS, UPPER CABINETS, SINK SYSTEM, COUNTER AND

COUNTER TOP; PATCH AND PREP WALL AS NEEDED FOR NEW

KITCHEN AREA AND PAINT PER FINISH SCHEDULE

02 41 16.22 DEMO EXISTING LIGHT FIXTURE

02 41 16.23 REMOVAL OF EXISTING CUBICLES; G.C. TO REMOVE -

COORDINATE LOCATION WITH COUNTY

3/16" = 1'-0"2 Area 03 - Ceiling Plan - Existing and Demo

R private room waiting reception

09 29 00.01

07 21 00.B1

3'-0"

2' -2

/8

" 2' -0

/4

2'-7 3/8" 5'-4 1/2"

3A300 3

3A300 hall office existing vestibule existing hall existing office existing vestibule existing

RR

existing

RR

existing stairexisting electrical room

(NO WORK IN

THIS AREA)

(NO WORK IN

THIS AREA)

(NO WORK IN

THIS AREA)

(NO WORK IN

THIS AREA)

(NO WORK IN

THIS AREA)

(NO WORK IN

THIS AREA)

(NO WORK IN

THIS AREA)

A1

3A30022

4' -0

9'-0"

9' -1

5/

8" office hall

6"

3/

4"

1'-6"

8'-1 9/16"

4"

3100A

A

U1

A1

A1

U1

U1

A002

Sim

3A300

4' -9

/4 storage office office

A1

A1

'-4

/2

9'

-4

/2

9' -5

A1

A1

10'-8 21/32"

6X8

CUBICLE

13'-10"

6'-3"

8' -0

4'-2 7/16" hall existing office

(NO WORK IN

THIS AREA)

existing office existing conference

(NO WORK IN

THIS AREA)

(NO WORK IN

THIS AREA)

A1

3"

11'-8"

12'-10 5/8"

3' -8

/1

6"

'-3

/1 6"

A

3109A

3110A

3111A

3A3002

3A300 5

3A300

1. REMOVE LOOSE PAINT AND

MISCELLANEOUS HANGING OBJECTS

FROM WALLS AND CEILINGS AT ALL

AREAS TO RECEIVE NEW FINISHES.

2. PATCH AND REPAIR ALL EXISTING

FLOOR SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION OR

PRIOR USE.

3. PATCH ALL AREAS OF ELECTRICAL

AND MECHANICAL DEMOLITION THAT

WILL NOT BE REUSED.

4. CONTRACTOR TO FIELD VERIFY ALL

EXISTING DIMENSIONS AND

CONDITIONS. IN THE EVENT OF A

DISCREPANCY BETWEEN THE

DRAWINGS AND THE EXISTING

CONDITIONS, NOTIFY THE ARCHITECT

BEFORE PROCEEDING.

5. DO NOT REMOVE ANY ITEMS WHICH

JEOPARDIZE THE STRUCTURAL

INTEGRITY OF THE BUILDING. IF

HIDDEN ELEMENTS OR DETERIORATED

ELEMENTS ARE ENCOUNTERED,

NOTIFY THE ARCHITECT IMMEDIATELY.

6. PROTECT ALL ADJACENT AREAS AND

ITEMS "TO REMAIN" DURING

DEMOLITION/CONSTRUCTION.

REPAIR/REPLACE ALL ITEMS DAMAGED

DURING CONSTRUCTION.

7. EXISTING BUILDING CONDITIONS

SHOWN ON THESE DRAWINGS ARE

DERIVED FROM DRAWINGS OF THE

ORIGINAL BUILDING AND FROM LIMITED

FIELD OBSERVATION.

8. THE CONTRACTOR SHALL PROVIDE

AND MAINTAIN ADDITIONAL MEANS OF

EGRESS AS NEEDED AS A RESULT OF

CONSTRUCTION SEQUENCING AND/OR

REGULATORY REQUIREMENTS.

GENERAL PROJECT NOTES

kuenyarch.com ©2020 Kueny Architects L.L.C. - All Rights Reserved

PLAN NORTH

KEYNOTE LEGEND

SCALE: As indicated

3A201Kenosha County - Victim Witness, Juvenile Intake and District Attorney Relocation and Partial Remodel Project

April 24, 2020

Area 03 - Proposed Plan

912 56th St, Kenosha, WI 53140

Spec. # Description

07 21 00.B1 BATT INSULATION

09 29 00.01 5/8" GYPSUM WALL BOARD; PAINT PER SCHEDULE

DOOR SCHEDULE - AREA 03

MARK

FROM ROOM TO ROOM

LABEL

DOOR FRAME

REMARKSNUM NAME NUM NAME TYPE MATERIAL SWING WIDTH HEIGHT THICKNESS LOUVER GLASS TYPE MATERIAL GLASS 3100A 3101 reception 3100 waiting - F Wood / BR Panel RHR 3' - 0" 7' - 0" 1 3/4" - - A - Solid core construction wood veneer faces, bullet-resistant composite core and solid 3/8 inch thick wood stile and rail edges of same species as veneer:Glazing to be bullet resistant Level III rated

3102A 3101 reception 3102 office - F - 3' - 0" 7' - 0" 1 3/4" - - A - - 3107A 3107 storage 3104 hall - F - 3' - 0" 7' - 0" 1 3/4" - - A - - 3109A 3108 hall 3109 office - F - 3' - 0" 7' - 0" 1 3/4" - - A - - 3110A 3108 hall 3110 office - F - 3' - 0" 7' - 0" 1 3/4" - - A - - 3111A 3108 hall 3111 office - F - 3' - 0" 7' - 0" 1 3/4" - - A - -

HARDWARE SCHEDULE - AREA 03

MARK LOCKSET PUSH-PULL HOLD OPEN CLOSER HINGE DOOR STOP THRESHOLD WEATHERSTRIP KICKPLATE SOUNDSTOP NAMEPLATE NOTES 3100A By Owner - - X X X - - - X - Lockset Provided by Owner; Installed by G.C.

3102A By Owner - - - X X - - - X - Lockset Provided by Owner; Installed by G.C.

3107A By Owner - - - X X - - - X - Lockset Provided by Owner; Installed by G.C.

3109A By Owner - - - X X - - - X - Lockset Provided by Owner; Installed by G.C.

3110A By Owner - - - X X - - - X - Lockset Provided by Owner; Installed by G.C.

3111A By Owner - - - X X - - - X - Lockset Provided by Owner; Installed by G.C.

ROOM SCHEDULE - AREA 03

NUMBER NAME FLOOR TYPE BASE

WALL FINISH CEILING

REMARKSNORTH SOUTH EAST WEST TYPE HEIGHT

3100 waiting CPT-1 4" VINYL Existing Existing GWB1/GL-3 Existing ACT-1 8'-5 3/4" 3101 reception CPT-1 4" VINYL Existing Existing Existing/GWB1 GWB1/GL-3 ACT-1 8'-5 3/4" 3102 office CPT-1 4" VINYL Existing GWB1 Existing GWB1 ACT-1 8'-5 3/4" 3103 hall CPT-1 4" VINYL GWB1 Existing Existing GWB1 ACT-1 8'-5 3/4" 3104 hall CPT-1 4" VINYL Existing Existing Existing Existing ACT-1 8'-5 3/4" 3105 existing office Existing Existing Existing Existing Existing Existing Existing 8'-5 3/4" 3106 existing office Existing Existing Existing Existing Existing Existing Existing 8'-5 3/4" 3107 storage CPT-1 4" VINYL Existing GWB1 GWB1 GWB1 ACT-1 8'-5 3/4" 3108 hall CPT-1 4" VINYL Existing/GWB1 Existing GWB1 Existing ACT-1 8'-5 3/4" 3109 office CPT-1 4" VINYL Existing GWB1 Existing GWB1 ACT-1 8'-5 3/4" 3110 office CPT-1 4" VINYL GWB1 GWB1 Existing GWB1 ACT-1 8'-5 3/4" 3111 office CPT-1 4" VINYL GWB1 Existing Existing Existing/GWB1 ACT-1 8'-5 3/4" 3112 existing conference Existing Existing Existing Existing Existing Existing Existing 8'-5 3/4" 3113 private room Existing Existing Existing Existing Existing Existing Existing 8'-5 3/4"

PAINT SCHEDULE - AREA 03

ROOM

FLOOR

WALLS

CEI…