2-Leonard Hall Renovation - Full Drawing Set 12-22-2025.pdf
PDF 38 MB Posted
- Attached to
- IN-1234 Leonard Hall Classroom Renovations
- Solicitation number
- US.215386
- Issued by
- Indiana County, Ingram Borough, Pennsylvania
About this file
This is a full drawing set for the Leonard Hall Classroom Renovations project at Indiana University of Pennsylvania, a state institution within the Pennsylvania State System of Higher Education. The project involves the renovation and construction of two large classrooms (Classrooms 1 and 2) and renovation of adjacent corridor spaces on the fourth floor of Leonard Hall, with associated mechanical, electrical, plumbing, fire protection, and structural work extending through the fifth floor and onto the roof. The scope includes demolition of existing interior partitions, finishes, and systems; construction of new partition walls with specific fire-rating requirements; installation of new HVAC ductwork and equipment including a rooftop unit (RTU-01); new plumbing connections for water coolers; new electrical systems including lighting, power distribution, fire alarm, and data communications; and new fire sprinkler modifications. The total fourth-floor work area encompasses approximately 7,115 square feet, representing 41.2 percent of the fourth floor's total 17,285 square feet. The pre-bid conference with mandatory site visit is scheduled for January 5, 2025, at 11:00 AM at Jane Leonard Hall, Room 407, 981 Grant Street, Indiana, Pennsylvania 15705. Electronic bids are due no later than 11:00 AM EST on January 27, 2026, through PennBid at https://pennbid.bonfirehub.com, with bid documents available at no cost through the same platform.
The project is classified as a Level 1 and Level 2 alteration under the International Existing Building Code (IEBC-2021), with the building occupancy partially changing from Business Group B to Assembly A-3 for classroom functions. The design must comply with the Pennsylvania Uniform Construction Code, 2021 International Building Code (IBC-2021), and applicable accessibility standards including ICC A117.1-2017. The renovation increases the fourth-floor occupant load from 344 to 409 occupants, requiring compliance with updated means of egress, plumbing fixture, and fire protection requirements. The building construction type is Type IIA with existing 1-hour fire-rated construction to be maintained; new work must achieve 1-hour fire barriers between the A-3 and B occupancies. Work shall be executed by Separate Prime Contractors with the General Construction Contractor serving as the Lead Prime Contractor responsible for overall project coordination and management. All contractors must coordinate with the design team, obtain necessary permits, and comply with OSHA safety standards and hazardous materials handling procedures concurrent with ongoing abatement work under a separate contract.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .