2-Leonard Hall Renovation - Full Drawing Set 12-22-2025.pdf
PDF 38 MB Posted
- Attached to
- IN-1234 Leonard Hall Classroom Renovations
- Solicitation number
- Not on record
- Issued by
- Indiana County, Ingram Borough, Pennsylvania
About this file
This is a full drawing set for the Leonard Hall Classroom Renovations project at Indiana University of Pennsylvania, a state institution within the Pennsylvania State System of Higher Education. The project involves the renovation and construction of two large classrooms (Classrooms 1 and 2) and renovation of adjacent corridor spaces on the fourth floor of Leonard Hall, with associated mechanical, electrical, plumbing, fire protection, and structural work extending through the fifth floor and onto the roof. The scope includes demolition of existing interior partitions, finishes, and systems; construction of new partition walls with specific fire-rating requirements; installation of new HVAC ductwork and equipment including a rooftop unit (RTU-01); new plumbing connections for water coolers; new electrical systems including lighting, power distribution, fire alarm, and data communications; and new fire sprinkler modifications. The total fourth-floor work area encompasses approximately 7,115 square feet, representing 41.2 percent of the fourth floor's total 17,285 square feet. The pre-bid conference with mandatory site visit is scheduled for January 5, 2025, at 11:00 AM at Jane Leonard Hall, Room 407, 981 Grant Street, Indiana, Pennsylvania 15705. Electronic bids are due no later than 11:00 AM EST on January 27, 2026, through PennBid at https://pennbid.bonfirehub.com, with bid documents available at no cost through the same platform.
The project is classified as a Level 1 and Level 2 alteration under the International Existing Building Code (IEBC-2021), with the building occupancy partially changing from Business Group B to Assembly A-3 for classroom functions. The design must comply with the Pennsylvania Uniform Construction Code, 2021 International Building Code (IBC-2021), and applicable accessibility standards including ICC A117.1-2017. The renovation increases the fourth-floor occupant load from 344 to 409 occupants, requiring compliance with updated means of egress, plumbing fixture, and fire protection requirements. The building construction type is Type IIA with existing 1-hour fire-rated construction to be maintained; new work must achieve 1-hour fire barriers between the A-3 and B occupancies. Work shall be executed by Separate Prime Contractors with the General Construction Contractor serving as the Lead Prime Contractor responsible for overall project coordination and management. All contractors must coordinate with the design team, obtain necessary permits, and comply with OSHA safety standards and hazardous materials handling procedures concurrent with ongoing abatement work under a separate contract.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MEP ENGINEER
STRUCTURAL ENGINEER
C
PROJECT ADDRESS:
CLIENT INFO:
470 Washington Road, Pittsburgh, PA 15228
412.561.7117 www.DRAWcollective.com
PROJECT / CLIENT INFO:LOCATION MAP:
REVISIONS
1659 PA-228
CRANBERRY TWP PA 16006
COMPANY PHONE: (724) 741-0848
BARBER & HOFFMAN
1051 BRINTON RD #100
PITTSBURGH, PA 15221
COMPANY PHONE: (412) 371-9073
H.F. LENZ
Au tod es k D oc s:/
/U
-2 5-
IU
P Le on ar d H all
T em p C
OM
S pa ce s/U
-2
5-
Le on ar d H all R
.rv t
/22 /20
6:
:22
P M
981 GRANT STREET INDIANA, INDIANA, PA, 15705
LEONARD HALL TEMP COM CLASSRM
RENOVATION
981 GRANT STREET
INDIANA, PA, 15705
INDIANA UNIVERSITY OF PENNSYLVANIA
ROBERTSHAW BUILDING
650 SOUTH THIRTEENTH ST
INDIANA, PA, 15705 CS
CO
VE
R
SH
EE
T
LE
ON
AR
D
HA
LL
T
EM
P
CO
M
CL
AS
SR
M
RE
NO
VA
TI
ON
IN
DI
AN
A
UN
IV
ER
SI
TY
O
F
PE
NN
SY
LV
AN
IA
R
OB
ER
TS
HA
W B
UI
LD
IN
G
Pr oj
No . U
-2
5-
Iss ue
D ate
2/2
2/2
CO
PY
RI
GH
T
Contact: Chris Brown Email:
chrisb@drawcollective.com
INDIANA UNIVERSITY OF PENNSYLVANIA ROBERTSHAW BUILDING
DRAWING INDEX
DR
AW
IN
G
NO
GENERAL
CS101 COVER SHEET
BC101 BUILDING CODE SUMMARY - GENERAL REQUIREMENTS
ARCHITECTURAL
A001 LEGENDS, ABBREVIATIONS, GENERAL NOTES AND INTERIOR PARTITION TYPES
A101 FOURTH FLOOR DEMO AND FLOOR PLAN
A102 FIFTH FLOOR & ROOF - PLAN
A601 DOOR SCHEDULES, DOOR AND FRAME TYPES
A701 FOURTH FLOOR - REFLECTED CEILING PLAN
A801 FOURTH FLOOR - INTERIOR LAYOUT PLAN
A901 INTERIOR ELEVATIONS
A921 INTERIOR DETAILS
FIRE PROTECTION
FP001 DEMAND SCHEDULE, GENERAL NOTES, SYMBOLS, DETAILS
FP201 FOURTH FLOOR PLAN - FIRE PROTECTION
PLUMBING
P001 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
P101 FOURTH FLOOR PLAN - PLUMBING
HVAC
M001 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
M101 FOURTH FLOOR PLAN - MECHANICAL DUCTWORK
M102 FIFTH FLOOR AND ROOF PLAN - MECHANICAL DUCTWORK
M201 FOURTH FLOOR PLAN - MECHANICAL PIPING
M401 DETAILS - MECHANICAL
M402 DETAILS - MECHANICAL
M501 SCHEDULES - MECHANICAL
ELECTRICAL
E001 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
E101 FOURTH FLOOR PLAN - POWER
E102 FIFTH FLOOR AND ROOF PLAN - POWER
E201 FOURTH FLOOR PLAN - LIGHTING
E401 ELECTRICAL DETAILS
E501 PANEL SCHEDULES
E502 PANEL SCHEDULES & LIGHTING FIXTURE SCHEDULE
E601 DIAGRAMS AND-OR RISERS - ELECTRICAL
NORTH
PROJ SCRN PROJ SCRN PROJ SCRN
PR
O
J
SC
R N
PR
O
J
SC
R N
UP
DN
UP
DN
NOTE: ALL OPERABLE ELEMENTS SHALL BE MOUNTED WITHIN THE REACH RANGES NOTED BELOW. OPERABLE ELEMENTS INCLUDE BUT ARE NOT LIMITED TO THERMOSTATS, LIGHT SWITCHES, WINDOW CONTROLS, INTERCOMS POWER AND DATA RECEPTACLES, SECURITY ALARM CONTROLS, GARAGE DOOR OPENERS, ACCESSIBLE MAILBOXES A/V CONTROLS, FIRE ALARM PULL STATIONS, APPLIANCES, SOAP DISPENSERS, FIRE EXTINGUISHERS, VENDING
MACHINES, ETC.
SEE DRAWINGS & SPECIFICATIONS FOR SPECIFIC MOUNTING HEIGHTS
OF OPERABLE ELEMENTS INCLUDING BUT NOT LIMITED TO ELECTRICAL
SWITCHES, CARD READERS, PULL STATIONS, VOLUME CONTROLS, ETC.
OBSTRUCTED HIGH SIDE REACH
10" MAX
" M
AX
" M
AX
255-610
>10-24
" M
AX
10" MAX
" M
AX
" M
AX
" M
AX
" M
AX
" M
IN
OBSTRUCTED HIGH FORWARD REACH
(a) (b)
UNOBSTRUCTED HIGH FORWARD REACH
20" MAX
" M
AX
>510-635
>20-25
" M
AX
UNOBSTRUCTED SIDE REACH
POLI-SCI DEPT
CHAIR OFFICE
407G
POLI-SCI
FACULTY OFFICE
407F
POLI-SCI
ADMIN
407H
POLI-SCI
FACULTY OFFICE
407I
STAIR 2
407S2
POLI-SCI
FACULTY OFFICE
407J
POLI-SCI
FACULTY OFFICE
407K
POLI-SCI
FACULTY OFFICE
407L
POLI-SCI
FACULTY OFFICE
407M
TOWN SQUARE
407B
POLI-SCI
FACULTY OFFICE
407E
POLI-SCI
FACULTY OFFICE
407D
POLI-SCI
FACULTY OFFICE
407C
CORRIDOR
406L
JOUR WORK AREA
406A
JOUR FACULTY
OFFICE
406K
JOUR FACULTY
OFFICE
406J
JOUR FACULTY
OFFICE
406I
JOUR FACULTY
OFFICE
406H
JOUR FACULTY
OFFICE
406G
JOUR FACULTY
OFFICE
406F
JOURN ADMIN
406E
JOUR FACULTY
OFFICE
406K
TOWN SQUARE
406C COAT
406B
ELEC
E403
DATA
E404
JAN
MEN'S
RESTROOM
WOMEN'S
RESTROOM
CORRIDOR
400H2
CORRIDOR
400H3
ELEVATOR LOBBY
400H1STAIR 1
407S1
CORRIDOR
407A
POLI-SCI
WORK AREA
407N
DIGITAL MEDIA
407N
JOURNALISM LAB
JOURNALISM LAB
PASSAGE
400H6
CORRIDOR
400H4
CORRIDOR
400H5
STAIR 4
400S4
ELEC
E415
STAIR 5
400S5
HVAC
SHAFT
HVAC
SHAFT
HVAC
SHAFT
2655 SF
CLASSROOM 1
3447 SF
CLASSROOM 2
HVAC SHAFT
EGRESS CAPACITY = 300 OCUPANTS
72" DOOR @ 0.15 PER OCC = 480 OCC
60" STAIR @ 0.20 PER OCC = 300 OCC
EXG CLASSROOM FUNCTION
785 SF @ 20 NET SF / OCC = 40 OCCUPANTS
EXG CLASSROOM FUNCTION
286 SF @ 20 NET SF / OCC = 20 OCCUPANTS
NEW CLASSROOM FUNCTION
2,655 SF @ 20 NET SF / OCC = 133 OCCUPANTS
EXG BUSINESS AREA FUNCTION
50 SF @ 150 GROSS SF / OCC = 1 OCCUPANT
EGRESS CAPACITY = 240 OCUPANTS
36" DOOR @ 0.15 PER OCC = 240 OCC
48" STAIR @ 0.20 PER OCC = 240 OCC
EXG ACCESSORY STORAGE / MECH FUNCTION
107 SF @ 300 GROSS SF / OCC = 1 OCCUPANT
NEW CLASSROOM FUNCTION
3,447 SF @ 20 NET SF / OCC = 173 OCCUPANTS
EGRESS CAPACITY = 240 OCUPANTS
36" DOOR @ 0.15 PER OCC = 240 OCC
48" STAIR @ 0.20 PER OCC = 240 OCC
NEW UNCONCENTRATED ASSEMBLY FUNCTION
90 SF @ 15 NET SF / OCC = 6 OCCUPANTS
NEW ACCESSORY STORAGE / MECH FUNCTION
99 SF @ 300 GROSS SF / OCC = 1 OCCUPANT
EGRESS CAPACITY = 240 OCUPANTS
36" DOOR @ 0.15 PER OCC = 240 OCC
48" STAIR @ 0.20 PER OCC = 240 OCC
EXG ACCESSORY STORAGE / MECH FUNCTION
189 SF @ 300 GROSS SF / OCC = 1 OCCUPANT
EXG BUSINESS AREA FUNCTION
4,806 SF @ 150 GROSS SF / OCC = 33 OCCUPANTS
FOURTH FLOOR EGRESS SUMMARY
TOTAL OCCUPANT LOAD: 409 OCCUPANTS
TOTAL EGRESS CAPACITY: 1,020 OCCUPANTS
110' TRAVEL DISTANCE
FROM MOST REMOTE POINT
2 HR FIRE BARRIER
1 HR FIRE BARRIER
2 HR FIRE BARRIER - EXISTING
1 HR FIRE BARRIER - EXISTING
LEVEL 2 CONSTRUCTION - PER IEBC
LEVEL 1 CONSTRUCTION - PER IEBC
NEW CONSTRUCTION
TRAVEL DISTANCE
GOVERNING CODES
PENNSYLVANIA UNIFORM CONSTRUCTION CODE (PA UCC)
INTERNATIONAL BUILDING CODE – 2021 EDITION (IBC-2021)
INTERNATIONAL EXISTING BUILDING CODE – 2021 EDITION (IEBC-2021)
INTERNATIONAL ENERGY CONSERVATION CODE – 2021 EDITION (IECC-2021)
INTERNATIONAL PLUMBING CODE – 2021 EDITION (IPC-2021)
INTERNATIONAL MECHANICAL CODE – 2021 EDITION (IMC-2021)
ACCESSIBLE BUILDINGS AND FACILITIES – 2017 EDITION (ICC A 117.1-2017)
BUILDING TYPE / CLASSIFICATION
OCCUPANCY CLASSIFICATION AND USE: BUSINESS GROUP B w/ ASSEMBLY A-3 AREAS
CONSTRUCTION TYPE: IIA
BUILDING HEIGHT (STORIES): 5 STORIES ABOVE GRADE PLANE / 1 STORY BELOW
BUILDING HEIGHT (FEET): FIFTH FLOOR IS 66 ’-9” ABOVE GRADE PLANE
BUILDING AREA: SEE SUMMARY TABLE BELOW
AUTOMATIC SPRINKLER SYSTEM: SPRINKLERED THROUGHOUT BUILDING
STANDPIPE SYSTEM: PROVIDED
FIRE ALARM AND DETECTION SYSTEM: THROUGHOUT BUILDING
EXISTING BUILDING CODE (IEBC-2021) ANALYSIS OF ALTERATIONS
LEVEL OF ALTERATIONS: LEVEL 1 AND 2 IN PROJECT AREA – SEE PLAN THIS SHEET
CHANGE OF OCCUPANCY: PARTIAL CHANGE FROM GROUP B TO ASSEMBLY A-3
ADDITIONS: NO ADDITIONS OR CHANGES TO OVERALL BUILDING
RELOCATED BUILDING: NOT A RELOCATED BUILDING
BUILDING WORK AREAS
LEVEL 2 ALTERATIONS USED AS EQUIVALENT FOR WORK AREA FOLLOWING THE DEFINITION OF “RECONFIGURED SPACES”
LEVEL EXIST AREA WORK AREA WORK AREA % OF TOTAL
GROUND FLOOR 17,247 SF NONE 0%
FIRST FLOOR 25,054 SF NONE 0%
SECOND FLOOR 25,212 SF NONE 0%
THIRD FLOOR 17,461 SF NONE 0%
FOURTH FLOOR 17,285 SF 7,115 SF 41.2%
FIFTH FLOOR 17,183 SF NONE 0%
TOTAL 119,442 SF 7,115 SF 5.9%
IEBC CHAP / CHAPTER HEADING
3 PROVISIONS FOR ALL COMPLIANCE METHODS
307.7.1 WERE AN ALTERATION AFFECTS THE ACCESSIBILTY TO, OR CONTAINS AN AREA OF PRIMARY FUNCTION, THE
ROUTE TO THE PRIMARY FUNCTION AREA SHALL BE ACCESSIBLE AND SHALL INCLUDE TOILET FACILITIES AND
DRINKING FOUNTAINS SERVING THE AREA OF PRIMARY FUNCTION.
6 CLASSIFICATION OF WORK
SEE PLAN FOR AREAS WITH ALTERATIONS AND CLASSIFICATION OF WORK (LEVEL 2 ALTERATIONS USED AS EQUIVALENT
FOR WORK AREA FOLLOWING THE DEFINITION OF “RECONFIGURED SPACES”)
604.1 WORK AREA DOES NOT EXCEED 50% OF THE BUILDING AREA; NO LEVEL 3 ALTERATIONS
7 ALTERATIONS – LEVEL 1
702 NEWLY INSTALLED WALLS, CEILING, TRIM, AND FLOOR FINISHES SHALL COMPLY WITH CHAPTER 8 OF THE
IBC-2021
8 ALTERATIONS – LEVEL 2
801.2 ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF CHAPTER 7
802.4 THE INTERIOR FINISH OF WALLS AND CEILINGS IN EXITS AND CORRIDORS IN ANY WORK AREA SHALL COMPLY
WITH THE REQUIREMENTS OF THE IBC-2021
805.4.1.1 IN ANY WORK AREA ALL ROOMS AND SPACES HAVING AN OCCUPANT LOAD GREATER THAN 50 OR IN WHICH THE TRAVEL DISTANCE TO AN EXIT EXCEEDS 75 ’ SHALL HAVE NOT FEWER THAN TWO EXIT DOORWAYS
804.5.4 IN ANY WORK AREA AND IN THE EGRESS PATH FROM ANY WORK AREA TO THE EXIT DISCHARGE, IN AREAS OF GROUP A OCCUPANCY WITH AN OCCUPANT LOAD GREATER THAN 100, ALL REQUIRED EXIT DOORS SHALL
HAVE PANIC OR FIRE EXIT HARDWARE
807.1 RECONFIGURED SPACES INTENDED FOR OCCUPANCY AND SPACE CONVERTED TO OCCUPIABLE SPACE IN ANY WORK AREA SHALL BE PROVIDED WITH NATURAL OR MECHANICAL VENTILATION PER THE IMC-2021
10 CHANGE OF OCCUPANCY
1001.2.2.1 WHERE THE OCCUPANCY CLASSIFICATION OR GROUP OF A PORTION OF AN EXISTING BUILDING IS CHANGED, SECTION 1011 SHALL APPLY
1011.3 IN AREAS OF THE BUILDING UNDERGOING THE CHANGE OF OCCUPANCY CLASSIFICATION, THE INTERIOR
FINISH OF WALLS AND CEILINGS SHALL COMPLY WITH THE REQUIREMENTS OF THE IBC-2021
1011.5 MEANS OF EGRESS HAZARD CATEGORY. EXISTING (B) = RELATIVE HAZARD CATEGORY 4; CHANGE TO (A) =
RELATIVE HAZARD CATEGORY 3. CHANGE IS TO HIGHER HAZARD CATEGORY
1011.5.1 MEANS OF EGRESS CHANGE TO HIGER HAZARD CATEGORY SHALL COMPLY WITH CHAPTER 10 OF THE I
BC-2021
1011.6 HEIGHT AND AREA HAZARD CATEGORY. EXISTING (B) = RELATIVE HAZARD CATEGORY 4; CHANGE TO (A-3) =
RELATIVE HAZARD CATEGORY 2. CHANGE IS TO HIGHER HAZARD CATEGORY
1011.6.1 HEIGHT AND AREA CHANGE TO A HIGHER HAZARD CATEGORY SHALL COMPLY WITH THE REQUIREMENTS OF
CHAPTER 5 OF THE IBC-2021
1011.7 EXTERIOR WALL FIRE RESISTANCE HAZARD CATEGORY. EXISTING (B) = RELATIVE HAZARD CATEGORY 3;
CHANGE TO (A) = RELATIVE HAZARD CATEGORY 3. NO CHANGE TO EXTERIOR WALL FIRE RESISTANCE HAZARD
CATEGORY
1011.7.2 WHERE A CHANGE OF OCCUPANCY CLASSIFICATION IS MADE TO AN EQUAL OR LESSER EXTERIOR WALL FIRE RESISTANCE HAZARD CATEGORY, EXTERIOR WALLS, INCLUDING OPENINGS, SHALL BE ACCEPTED
1011.8.2 WHEN THE MEANS OF EGRESS CHANGE IS TO A HIGHER HAZARD CATEGORY, INTERIOR STAIRWAYS SHALL BE
ENCLOSED AS REQUIRED BY THE INTERNATIONAL BUILDING CODE
1011.8.3 WHEN THE MEANS OF EGRESS CHANGE IS TO A HIGHER HAZARD CATEGORY, INTERIOR VERTICAL SHAFTS OTHER THAN STAIRWAYS, INCLUDING BUT NOT LIMITED TO ELEVATOR HOISTWAYS AND SERVICE AND UTILITY
SHAFTS SHALL BE ENCLOSED AS REQUIRED BY THE IBC-2021
IBC CHAP / CHAPTER HEADING
3 USE AND OCCUPANCY CLASSIFICATION
303.4 ASSEMBLY GROUP A-3 (EXISTING AND NEW) FOR CLASSROOMS W/ OCCUPANT LOAD > 50
304.1 BUSINESS GROUP B (EXISTING) FOR OFFICE USE AND EDUCATIONAL OCCUPANCIES FOR STUDENTS
ABOVE THE 12TH GRADE
4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
NONE APPLY
5 GENERAL BUILDING HEIGHTS AND AREAS
504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE= 85 ’ FOR A AND B OCCUPANCIES
(EXISTING IS 66 ’-9”)
504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE = 6 STORIES FOR B OCCUPANCIES; 4 STORIES FOR A-3 OCCUPANCIES (EXISTING IS 5 STORIES ABOVE GRADE PLANE; NO A-3 OCCUPANCIES ABOVE 4
STORIES ABOVE GRADE PLANE)
506.2 ALLOWABLE AREA = 112,500/STORY FOR B OCCUPANCY*; 46,500/STORY FOR A-3 OCCUPANCY* (LARGEST STORY IS 25,212 SF; FOURTH FLOOR IS 17,285 SF) *NOT INCLUDING FRONTAGE INCREASE
508.4 BUILDINGS OR PORTIONS OF BUILDINGS THAT COMPLY WITH THE PROVISIONS OF THIS SECTION SHALL
BE CONSIDERED SEPARATED OCCUPANCIES
508.4.3 EACH SEPARATED OCCUPANCY SHALL COMPLY WITH THE BUILDING HEIGHT LIMITATIONS AND STORY LIMITATIONS (SEPARATED A-3 OCCUPANCIES LIMITED TO THE FOURTH FLOOR OF THE BUILDING AND BELOW)
508.4.4 REQUIRED SEPARATION BETWEEN A AND B OCCUPANCIES = 1 HOUR FIRE BARRIER (TABLE 508.4)
6 TYPES OF CONSTRUCTION
TYPE IIA CONSTRUCTION (EXISTING TO BE MAINTAINED)
TABLE 601 FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS
PRIMARY STRUCTURAL FRAME: 1 HR
BEARING WALLS – EXTERIOR: 1 HR
BEARING WALLS – INTERIOR: 1 HR
NONBEARING WALLS AND PARTITIONS – EXTERIOR: 0 HRS
NONBEARING WALLS AND PARTITIONS – INTERIOR: 0 HRS
FLOOR CONSTRUCTION AND SECONDARY MEMBERS: 1 HR
ROOF CONSTRUCTION AND SECONDARY MEMBERS: 1 HR
7 FIRE AND SMOKE PROTECTION FEATURES
713.4 SHAFT ENCLOSURES SHALL HAVE A FIRE RESISTANCE RATING OF NOT LESS THAN 1 HOUR WHERE CONNECTING LESS THAN FOUR
STORIES; SHAFT ENCLOSURES SHALL HAVE A FIRE RESISTANCE RATING NOT LESS THAN THE FLOOR ASSEMBLY PENETRATED (1 HOUR)
716.1 OPENING PROTECTIONS REQUIREMENTS PER TABLE 716.1(2)
OPENING FIRE PROTECTION FOR 1 HOUR / OTHER FIRE BARRIERS:
MINIMUM FIRE DOOR ASSEMBLY RATING: ¾ HR
DOOR VISION PANEL SIZE: MAX TESTED
VISION PANEL GLAZING MARKING: D-H
MIN SIDELIGHT / TRANSOM RATING: ¾ HR
SIDELIGHT / TRANSOM GLAZING MARKING: D-H
8 INTERIOR FINISHES
803.13 INTERIOR WALL AND CEILING FINISH MATERIALS SHALL HAVE A FLAME SPREAD INDEX NOT GREATER THAN THE FOLLOWING:
SPACE SPRINKLERED B SPRINKLERED A-3
EXIT STAIRWAYS AND PASSAGEWAYS B B
CORRIDORS AND EXIT ENCLOSURES C B
ROOMS AND ENCLOSED SPACES C C
9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
903 AUTOMATIC SPRINKLER SYSTEM – PROVIDED THROUGHOUT BUILDING
905 STANDPIPE SYSTEMS – PROVIDED IN BUILDING
906 PORTABLE FIRE EXTINGUISHERS – PROVIDED
907 FIRE ALARM AND DETECTION SYSTEM – PROVIDED THROUGHOUT BUILDING
10 MEANS OF EGRESS
1004 OCCUPANT LOAD – SEE FOURTH FLOOR SUMMARY ON DRAWING THIS SHEET; TOTAL FLOOR OCCUPANT LOAD = 409 (WAS 344)
1005 MEANS OF EGRESS SIZING – SEE FOURTH FLOOR SUMMARY ON DRAWING THIS SHEET BASED ON THE CAPACITY SIZING BELOW;
TOTAL FLOOR CAPACITY = 1,020 OCCUPANTS
STAIRWAYS = 0.2” PER OCCUPANT (EXCEPTION 1 TO 1005.3.1)
OTHER EGRESS COMPONENTS = 0.15 ” PER OCCUPANT (EXCEPTION 1 TO 1005.3.2)
1006.3.3 MINIMUM NUMBER OF EXITS FROM STORY = 2 (4 PROVIDED; 2 WITH DIRECT ACCESS FROM CORRIDOR)
1017.2 EXIT ACCESS TRAVEL DISTANCE SHALL NOT EXCEED 250 FEET FOR A OCCUPANCIES (110 ’ TRAVEL DISTANCE FROM MOST REMOTE
POINT PROVIDED)
1020.2 CORRIDOR FIRE RESISTANCE RATING REQUIRED: 0 HR
IPC CHAPTER CHAPTER HEADING
4 FIXTURES, FAUCETS AND FIXTURE FITTINGS
403.1 MINIMUM PLUMBING FACILITIES
NOTE: THIS SUMMARY USES THE CODE SUMMARY DRAWINGS FOR THE ORIGINAL BUILDING (11/14/2014 L&I PLAN REVISION) AS BASIS TO
ANALYZE THE CHANGES TO THE FOURTH FLOOR OF THE BUILDING
BUILDING EXISTING REQUIRED FIXTURES (OCC LOAD FROM ORIGINAL PERMIT DRAWINGS)
ELEMENT NON-INSTRUCTIONAL / B INSTRUCTIONAL / A-3 TOTAL*
OCC LOAD: 1,634 1,508 3,142
MALE FIXTURE REQUIREMENTS
MALE OCC LOAD: 817 754 1,571
MALE WC RATE: 1 per 25 FIRST 50 1 per 125
1 per 50 OVER 50
MALE WC** NO: 17.34 6.03 24
MALE LAV RATE: 1 per 40 FIRST 80 1 per 200
1 per 80 OVER 80
MALE LAV NO: 11.21 3.77 15
FEMALE FIXTURE REQUIREMENTS
FEMALE OCC LOAD: 817 754 1,571
FEMALE WC RATE: 1 per 25 FIRST 50 1 per 65
1 per 50 OVER 50
FEMALE WC NO: 17.34 11.60 29
FEMALE LAV RATE: 1 per 40 FIRST 80 1 per 200
1 per 80 OVER 80
FEMALE LAV NO: 11.21 3.77 15
DRINK FOUNTAIN RATE: 1 per 100 1 per 500
DRINK FOUNTAIN NO: 16.34 3.02 20
SERVICE SINK NO: 1 1 2
*PER 403.1.1, FRACTIONAL FIXTURE NUMBERS FOR EACH OCCUPANCY ARE ADDED BEFORE ROUNDING UP TO THE NEAREST WHOLE
NUMBER
**COUNT INCLUDES URINALS
PROPOSED CHANGES: FOURTH FLOOR INCREASE TO 409 OCCUPANTS (FROM 344) = INCREASE OF 156 INSTRUCTIONAL / A-3; REDUCTION OF
91 NON-INSTRUCTIONAL / B (NET INCREASE OF 65 OCCUPANTS)
UPDATED REQUIRED FIXTURES (W/ FOURTH FLOOR CHANGES)
ELEMENT NON-INSTRUCTIONAL / B INSTRUCTIONAL / A-3 TOTAL*
OCC LOAD: 1,543 1,664 3,207
MALE FIXTURE REQUIREMENTS
MALE OCC LOAD: 772 832 1,604
MALE WC RATE: 1 per 25 FIRST 50 1 per 125
1 per 50 OVER 50
MALE WC** NO: 16.44 6.66 24
MALE LAV RATE: 1 per 40 FIRST 80 1 per 200
1 per 80 OVER 80
MALE LAV NO: 10.65 4.16 15
FEMALE FIXTURE REQUIREMENTS
FEMALE OCC LOAD: 772 832 1,604
FEMALE WC RATE: 1 per 25 FIRST 50 1 per 65
1 per 50 OVER 50
FEMALE WC NO: 16.44 12.80 30
FEMALE LAV RATE: 1 per 40 FIRST 80 1 per 200
1 per 80 OVER 80
FEMALE LAV NO: 10.65 4.16 15
DRINK FOUNTAIN RATE: 1 per 100 1 per 500
DRINK FOUNTAIN NO: 15.43 3.33 19
SERVICE SINK NO: 1 1 2
*PER 403.1.1, FRACTIONAL FIXTURE NUMBERS FOR EACH OCCUPANCY ARE ADDED BEFORE ROUNDING UP TO THE NEAREST WHOLE
NUMBER
**COUNT INCLUDES URINALS
PROVIDED IN BUILDING
ORIG NEW
ELEMENT REQ’D REQ’D PROVIDED BLDG NET
MALE WC**: 24 24 35 +11
FEMALE WC: 29 30 39 +9
UNASSIGNED WC: - - 2 +2
MALE LAV: 15 15 24 +9
FEMALE LAV: 15 15 26 +11
UNASSIGNED LAV: - - 2 +2
DRINKING FOUNTAIN: 20 19 20 +1
SERVICE SINK: 2 2 4 +2
**COUNTS INCLUDE URINALS
BUILDING-WIDE SURPLUS OF ALL FIXTURE TYPES REMAINS AFTER OCCUPANT LOAD CHANGES TO FOURTH FLOOR
BUILDING CODE ANALYSIS SUMMARY CONT'D
C
0 W as hin gto n R oa d, Pi tts bu rg h, PA
2.5
.71 ww w.
DR
AW
co lle cti ve
.co m
RE
VI
SI
ON
S
Au tod es k D oc s:/
/U
-2 5-
IU
P Le on ar d H all
T em p C
OM
S pa ce s/U
-2
5-
Le on ar d H all R
.rv t
/22 /20
6:
:25
P M
BC
BU
ILD
IN
G
CO
DE
S
UM
MA
RY
GE
NE
RA
L
RE
QU
IR
EM
EN
TS
LE
ON
AR
D
HA
LL
T
EM
P
CO
M
CL
AS
SR
M
RE
NO
VA
TI
ON
IN
DI
AN
A
UN
IV
ER
SI
TY
O
F
PE
NN
SY
LV
AN
IA
R
OB
ER
TS
HA
W B
UI
LD
IN
G
S
OU
TH
TH
IR
TE
EN
TH
S T
IN
DI
AN
A, P
A, 1 G
RA
NT
S
TR
EE
AN
A, P
A, Pr oj
No . U
-2
5-
Iss ue
D ate
2/2
2/2
CO
PY
RI
GH
T
ACCESSIBLE HEIGHTS AND REACH RANGES OF OPERABLE ELEMENTS
BC101
FOURTH FLOOR CODE ANALYSIS PLAN
1/16" = 1'-0"
CODE STUDY LEGEND
CONCRETE BLOCK
SECTIONS/ SECTIONAL DETAILS
CAST-IN-PLACE-CONCRETE CONCRETE BLOCK WALLS
PLANS/ PLAN DETAIL GRAPHICS
CAST-IN-PLACE-CONCRETE
WALLS
METAL STUD WALLS
STRUCTURAL/MISCELLANEOUS
STEEL
EARTH
GRAVEL/ENGINEERED FILL
STONE, OR NATURAL
BUILDING STONE
PLASTER OR GYPSUM
BOARD, OR EXTERIOR
SHEATHING
BATT INSULATION
ROOF, TAPERED, CAVITY OR RIGID
INSULATION
FINISHED WOOD TRIM
BRICK WALLS, OR PORTIONS OF
WALLS
NEW CONCRETE SLABS AND/OR
CONCRETE SIDEWALKSPLYWOOD
SPECIAL MASONRY WALLS, OR
PORTIONS OF WALLS - SGFT, OR
GROUND-FACED - ETC.
CAVITY DRAINAGE MATERIAL
A101
SIM
WALL SECTION
DETAIL OR ENLARGED
PLAN REFERENCE
NEW COLUMN GRID MARKER
W99
A300
EXTERIOR ELEVATION
INTERIOR/CASEWORK
ELEVATION
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
SE-#
# EXISTING COLUMN GRID
MARKER
A101.1
CABINET MARKERCab_Type_Num W D H
1'-0" 1t CEILING TAG W/ELEVATION
FLOOR TRANSITION
A101
SIM
ROOM
XF999
CODE TAG, ROOM NAME,
AREA & OCCUPANCY
A101
SIM
C6a
VCT CPT
FE
FEC
BUILDING SECTION
A101
SIM
A101
SIM
FLOOR ELEVATION WORK POINT
X
WT-#
X
DOOR TAG
REVISION TAG
ROOM NAME & NUMBER
SPECIALTY EQUIPMENT TAG
WINDOW TAG
WINDOW TREATMENT
ROOM
150 SF
X
Type AREA: Adjusted Area
REVISION CLOUD
WALL TYPES
EXISTING DOOR AND/OR FRAME TO REMAIN - SEE
DOOR SCHEDULE FOR ANY ADDITIONAL WORK
EXISTING DOOR AND/OR FRAME TO BE REMOVED -
SEE DEMO PLAN/NOTES
NEW DOOR AND/OR FRAME TO BE PROVIDED -
SEE DOOR SCHEDULE
FIRE RATING DESIGNATIONS
CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING ALL FIRE
PARTITIONS TO MEET IBC 2021 REQUIREMENTS. ALL FIRE
PARTITIONS SHALL BE CONSTRUCTED TO FLOOR OR ROOF DECK
ABOVE AND SEALED AIR-TIGHT WITH DEFLECTION HEADS AND
FIRE SAFING. ALL FIRE PARTITIONS SHALL BE PER ASSEMBLIES
NOTED ON WALL TYPES LEGEND, AND EXTEND BEYOND BUILDING
ENVELOPE AND BE SEPARATE FROM STRUCTURE AS PER IBC 2021.
SEE PLANS FOR LOCATIONS.
DOOR DESIGNATIONSWALL DESIGNATIONS
NEW STUD WALL
NEW STUD WALL - W/ SOUND
BATT INSULATION
NEW BRICK WALL OR
PORTION OF WALL
NEW MASONRY WALL OR
PORTION OF WALL
CAST-IN-PLACE CONCRETE
WALL OR PORTION OF WALL
SPECIAL MASONRY WALLS,
OR PORTIONS OF WALLS -
SGFT, OR GROUND FACED -
ETC
2 HR FIRE BARRIER
1 HR FIRE BARRIER
EXISTING WALL TO REMAIN
DEMOLISHED WALL
2 HR FIRE BARRIER - EXISTING
1 HR FIRE BARRIER - EXISTING
IF WALL IS RATED, INSTALL FIRESAFING
AND FIRE SEALANT MATERIALS
CONTINUOUS BOTH SIDES
ST
RU
CT
UR
AL
D
RA
W
IN
GS
HE
IG
HT
V
AR
IE
S
- S
EE
S
EC
IO
NS
A
ND
CLG MAY OR MAY NOT OCCUR
ON ONE OR BOTH SIDES OF WALL
METAL STUDS @ 16" O.C. - SIZE
VARIES. SEE TYPE
(1) LAYER OF 5/8" GPBD EACH SIDE -
TYPE PER SPECS
SOUND BATT INSUL TO DECK WHERE
INDICATED - MIN. THICKNESS TO
MATCH STUD WIDTH
2 1/2" MTL STUD & GPBD PARTITION TO DECK (3 3/4")
C2
2 1/2" MTL STUD & GPBD PARTITION TO DECK W/ BATTS (3 3/4")
C2a
3 5/8" MTL STUD & GPBD PARTITION TO DECK (4 7/8")
C3
3 5/8" MTL STUD & GPBD PARTITION TO DECK W/ BATTS (4 7/8")
C3a
6" MTL STUD & GPBD PARTITION TO DECK (7 1/4")
C6
6" MTL STUD & GPBD PARTITION TO DECK W/ BATTS (7 1/4")
C6a
VERTICAL SLIP CONNECTION
ST
RU
CT
UR
AL
D
RA
W
IN
GS
HE
IG
HT
V
AR
IE
S
- S
EE
S
EC
TI
ON
A
ND
CLG MAY OR MAY NOT OCCUR
ON ONE OR BOTH SIDES OF WALL
METAL STUDS @ 16" O.C. - SIZE
VARIES. SEE TYPE
(1) LAYER OF 5/8" GPBD EACH SIDE -
TYPE PER SPECS
SOUND BATT INSUL TO DECK WHERE
INDICATED - MIN. THICKNESS TO
MATCH STUD WIDTH
2 1/2" MTL STUD & GPBD PARTITION TO ABOVE CEILING (3 3/4")
D2
2 1/2" MTL STUD & GPBD PARTITION TO ABOVE CEILING W/ BATTS (3 3/4")
D2a
3 5/8" MTL STUD & GPBD PARTITION TO ABOVE CEILING (4 7/8")
D3
3 5/8" MTL STUD & GPBD PARTITION TO ABOVE CEILING W/ BATTS (4 7/8")
D3a
6" MTL STUD & GPBD PARTITION TO ABOVE CEILING (7 1/4")
D6
6" MTL STUD & GPBD PARTITION TO ABOVE CEILING W/ BATTS (7 1/4")
D6a
MI
N6"
IF WALL IS RATED, INSTALL FIRESAFING
AND FIRE SEALANT MATERIALS
CONTINUOUS BOTH SIDES
AN
D
ST
RC
UT
UR
AL
D
RA
W
IN
GS
HE
IG
HT
V
AR
IE
S
- S
EE
S
EC
TI
ON
S
CLG MAY OR MAY NOT OCCUR
ON ONE OR BOTH SIDES OF WALL
METAL STUDS @ 16" O.C. - SIZE
VARIES. SEE TYPE
(2) LAYER OF 5/8" GPBD EACH SIDE -
TYPE PER SPECS
SOUND BATT INSUL TO DECK WHERE
INDICATED - MIN. THICKNESS TO
MATCH STUD WIDTH
2 1/2" MTL STUD & GPBD PARTITION TO DECK (5")
E2
2 1/2" MTL STUD & GPBD PARTITION TO DECK W/ BATTS (5")
E2a
3 5/8" MTL STUD & GPBD PARTITION TO DECK (6 1/8")
E3
3 5/8" MTL STUD & GPBD PARTITION TO DECK W/ BATTS (6 1/8")
E3a
6" MTL STUD & GPBD PARTITION TO DECK (8 1/2")
E6
6" MTL STUD & GPBD PARTITION TO DECK W/ BATTS (8 1/2")
E6a
VERTICAL SLIP CONNECTION VERTICAL SLIP CONNECTION
RE
FL
EC
TE
D
CE
ILI
NG
P
LA
N
HE
IG
HT
V
AR
IE
S
- S
EE
6"
M
IN
CLG
(1) LAYER OF 5/8" GPBD THIS SIDE -
TYPE PER SPECS
LAMINATED GPBD ONE SIDE TO ABOVE CEILING (5/8")
K1
NEW OR EXIST WALL
IF WALL IS RATED, INSTALL FIRESAFING
AND FIRE SEALANT MATERIALS
CONTINUOUS BOTH SIDES
ST
RU
CT
UR
AL
D
RA
W
IN
GS
HE
IG
HT
V
AR
IE
S
- S
EE
S
EC
TI
ON
S
AN
D
CLG MAY OR MAY NOT OCCUR
ON ONE SIDE OF WALL
C-H STUDS @ 24" O.C. - SIZE
VARIES. SEE TYPE
1/2" OR 5/8" FIRE CODE 'X' GPBD PROVIDE
(2) LAYERS AT 2 HR RATED WALLS
STEEL RUNNER CHANNEL IN BED OF SEALANT
2 1/2" MTL STUD & GPBD PARTITION TO DECK (3 3/4")
M2
4" MTL STUD & GPBD PARTITION TO DECK (5 1/4")
M4
4" MTL STUD & GPBD PARTITION TO DECK W/ BATTS (5 1/4")
M4a
STEEL 'J' RUNNER AND DEFLECTION TRACK
1" GYPSUM LINER PANEL
EXTEND GPBD TO DECK ON ONE
SIDE AT WALLS WHERE SOUND
BATT INSUL IS INDICATED
NOTE:
WHERE 1 HR RATED WALLS OCCUR ON
PLANS, PROVIDE UL #U419
NOTE:
WHERE 2 HR RATED WALLS OCCUR ON
PLANS, PROVIDE UL #U419
NOTE:
1. 'H' PORTION OF STUDS ON THE UNFINISHED SIDE OF THE WALL
2. WHERE RATED WALLS OCCUR ON PLANS, PROVIDE UL #U415
3. COMPLETE CONSTRUCTION OF WALL BEFORE CONSTRUCTING
ANY BULKHEAD AT THIS WALL TYPE
C
0 W as hin gto n R oa d, Pi tts bu rg h, PA
2.5
.71 ww w.
DR
AW
co lle cti ve
.co m
RE
VI
SI
ON
S
Au tod es k D oc s:/
/U
-2 5-
IU
P Le on ar d H all
T em p C
OM
S pa ce s/U
-2
5-
Le on ar d H all R
.rv t
/22 /20
6:
:27
P M
A0
LE
GE
ND
S, A
BB
RE
VI
AT
IO
NS
, G
EN
ER
AL
NO
TE
S
AN
D
IN
TE
RI
OR
P
AR
TI
TI
ON
T
YP
ES
LE
ON
AR
D
HA
LL
T
EM
P
CO
M
CL
AS
SR
M
RE
NO
VA
TI
ON
IN
DI
AN
A
UN
IV
ER
SI
TY
O
F
PE
NN
SY
LV
AN
IA
R
OB
ER
TS
HA
W B
UI
LD
IN
G
S
OU
TH
TH
IR
TE
EN
TH
AN
A, P
A, 1 G
RA
NT
S
TR
AN
A, P
A, Pr oj
No . U
-2
5-
Iss ue
D ate
2/2
2/2
CO
PY
RI
GH
T
GRAPHICS CONVENTIONS
A
< ANGLE
@ AT
A/C AIR CONDITIONING
AB ANCHOR BOLT
ACM ASBESTOS CONTAINING MATERIALS
ACOUS ACOUSTIC
AD AREA DRAIN
ADJ ADJUSTABLE
AED AUTOMATED EXTERNAL DEFIBRILLATOR
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APC ACOUSTICAL PANEL CEILINGS
APPROX APPROXIMATE(LY)
ARCH ARCHITECT OR ARCHITECTURAL
ASPH ASPHALT
ASST ASSISTANT
AUTO AUTOMATIC
AVG AVERAGE
B
B/ BOTTOM OF
B/C BOTTOM OF CURB
BC BASE CABINET
BD BOARD
BET BETWEEN
BEV BEVELED
BIT BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BMK BENCH MARK
BOT BOTTOM
BR BRICK
BRG BEARING
BRKT BRACKET
BSMT BASEMENT
BUR BUILT-UP ROOF
C
[ CHANNEL
CAB CABINET
CB CATCH BASIN
CC CENTER TO CENTER
CEM PL CEMENT PLASTER
CF COMPOSITION FLOORING, OR CUBIC FOOT
CG CORNER GUARD
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLO CLOSET
CLR CLEAR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CP COPIER
CPT CARPET
CRSE COURSE
CS CONCRETE W/SEALER
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR COUNTER
CUH CABINET UNIT HEATER
CW CURTAINWALL
CY CUBIC YARD
D
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIFF DIFFUSER
DIM DIMENSION
DIR DIRECTOR
DN DOWN
DR DOOR
DW DISHWASHER
DWG DRAWING
DRAWING ABBREVIATION LIST
E
E EAST
EA EACH
EB EDGE BANDING
EFM ENTRANCE FLOOR MAT
EIFS EXTERIOR INSULATION FINISH SYSTEM
EJ EXPANSION JOINT
EL SHT ELASTIC SHEET
ELE ELEVATOR
ELEC ELECTRICAL
ELEV ELEVATION
EMER EMERGENCY
ENCL ENCLOSE(URE)
ENGR ENGINEER
ENT ENTRANCE
EP ELECTRICAL PANEL / EPOXY PAINT
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXC EXCAVATE
EXCL EXCLUDE(ING)
EXIST EXISTING
EXP BLT EXPANSION BOLT
EXT EXTERIOR
F
F FABRIC
F/F FACE TO FACE
FAX FACSIMILE
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET W/ FIRE
EXTINGUISHER
FHC FIRE HOSE CABINET
FIN FINISH OR FINISHED
FL FLOOR
FL CO FLOOR CLEAN OUT
FLSH FLASH OR FLASHING
FP FIRE PROTECTION
FPRF FIREPROOF OR FIREPROOFING
FR FIRE RATED OR FRAME
FRP FIBERGLASS REINFORCED PLASTIC
FRSG FIRE RATED SAFETY GLAZING
FRT FIRE RETARDANT - TREATED WOOD
FT FOOT / FEET
FTG FOOTING
FURN FURNISH
G
GA GAUGE
GALV GALVANIZED
GCT GLAZED CERAMIC TILE
GCTB GLAZED CERAMIC TILE BASE
GD GRADE(ING)
GL GLASS OR GLAZING
GPBD GYPSUM DRYWALL BOARD
GRAN GRANITE
GRAV GRAVEL
GRD GROUND
GRT GROUT
H
HB HOSE BIBB
HC HANDICAP(PED)
HCWD HOLLOW-CORE WOOD
HD HEAD
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR OR HANDRAIL
HT HEIGHT
HTR HEATER
HVAC HEATING/VENTILATION/AIR CONDITIONING
HWC HOT WATER CONVECTOR
I
ICRA INFECTION CONTROL RISK ASSESSMENT
ID INSIDE DIAMETER
IN IINCH, INCHES,INVERT
INCL INCLUDE, INCLUDED, OR INCLUDING
INSUL IINSULATION
INT IINTERIOR
J
JAN JANITOR
JB JAMB
JST JOIST
JT JOINT
K
KIT KITCHEN
L
LAM LAMINATE OR LAMINATED
LAN LOCAL AREA NETWORK CONNECTION
LAV LAVATORY
LB POUND
LF LINEAL FOOT
LGT LENGTH
LIN LINOLEUM
LINB LINOLEUM SHEET FLOORING - COVED
LKR LOCKER
LL LEAD LINED
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LP LOW POINT
LT LIGHT
LTL LINTEL
LVR LOUVER
LWOD LESS WIDTH OF DOOR
M
MAS MASONRY
MAX MAXIMUM
MBL MARBLE
MCT MOSAIC CERAMIC TILE
MDF MEDIUM DENSITY FIBREBOARD
MECH MECHANICAL
MEMB MEMBRANE
MEZZ MEZZANINE
MF MICROFICHE
MFR MANUFACTURE OR MANUFACTURE
MH MANHOLE
MICRO MICROWAVE
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOULDING
MLTP MULTIPLE
MO MASONRY OPENING
MON MONITOR
MTD MOUNTED EL
MTL METAL
N
N NORTH
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NM NORMAL
NOM NOMINAL
NTS NOT TO SCALE
NUM NUMBER
O
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OPNG OPENING
OPP OPPOSITE
OZ OUNCE
P
PART PARTITION
PC PERSONAL COMPUTER
PED PEDESTAL
PERF PERFORATED
PERM PERIMETER
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLAST PLASTIC
PLB PLUMBING
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
POS POINT OF SALE
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATED
PREMLD PREMOLDED
PRI PRINTER
PROP PROPERTY
PROT PROTECT, PROTECTED, OR PROTECTION
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
PT POINT
PTD PAINTED
PVC POLY VINYL CHLORIDE
Q
QT QUARRY TILE
QTB QUARRY TILE BASE
QUAL QUALITY
R
R RISER OR RODS
RB RUBBER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFER / REFERENCE
REFL REFLECTED
REG REGISTER
REINF REINFORCING
REQ'D REQUIRED
RES RESILIENT
RF ROOF
RFG REFRIGERATOR
RFT RUBBERIZED FABRIC TILE
RG RANGE
RM ROOM
RND ROUND
RO ROUGH OPENING
RSF RUBBER SHEET FLOORING
RT RIGHT
RT&R RUBBER STAIR TREAD & RISER
RTS RUBBER TRANSITION STRIP
RWC RAIN WATER CONDUCTOR
S
S SOUTH
SAN SANITARY
SC SPECIAL COATING
SCHD SCHEDULE
SCVC SOLID-CORE VINYL CLAD
SCWD SOLID-CORE WOOD
SEC SECTION
SERV SERVICE
SF SQUARE FOOT / STOREFRONT
SFC STORE FIXTURE CONTRACTOR
SHB STEEL HEAT BARRIER
SHT SHEET
SHTH SHEATHING
SI SQUARE INCH
SIM SIMILAR
SLD SOLID
SPEC SPECIFY, SPECIFIED OR SPECIFICATIONS
SPKLR SPRINKLER
SQ SQUARE
SS STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
ST STREET
STD STANDARD
STL STEEL
STN STONE
STOR STORAGE
STRUC STRUCTURAL
SUPPT SUPPORT(ING)
SURF SURFACE
SUSP SUSPEND, SUSPENDED, OR SUSPENSION
SY SQUARE YARD
SYN SYNTHETIC
SYS SYSTEM
T
"T" TEE (BAR OR W)
T TREAD
T/ TOP OF
T/C TOP OF CURB
TB TACKBOARD
TC TERRA COTTA
TEL TELEPHONE
TEMP TEMPERED OR TEMPERATURE
TERM TERMINATE / TERMINAL
TERR TERRAZZO
TERRT&R TERRAZZO TREAD & RISER
THRESH THRESHOLD
TLT TOILET
TRTD TREATED
TV TELEVISION
TYP TYPICAL
U
U/S UNDERSIDE
UCT UNGLAZED CERAMIC TILE
UH UNIT HEATER
UL UNDERWRITER'S LABORATORY
UMCT UNGLAZED MOSAIC CERAMIC TILE
UNO UNLESS NOTED OTHERWISE
V
VASF VINYL ATHLETIC SHEET FLOORING
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VVB VENTED VINYL BASE
VWC VINYL WALLCOVERING
W
W WEST
W/ WITH
WC WATER CLOSET OR WALL CABINET
WCM WALL COVERING MATERIAL
WCS WOOD GRAIN STEEL
WD WOOD / WOOD PANEL MILLWORK
WDAF WOOD ATHLETIC FLOORING
WF WOOD FLOORING
WFP WOOD FIBER PANEL
WN WINDOW
WP WATERPROOF(ING)
WS WORKSTATION
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
Y
YR YEAR
Z
"Z" ZEE
GRAPHIC SYMBOLS LEGEND
PLAN COMPONENTS
WALL TYPES
UPUP
B C D E F G
5.2
B.3 B.9 C.3 D.3D.4 H
JOURNALISM LAB
JOURNALISM LAB
STAIR 4
400S4
ELEC
E415
STAIR 5
400S5
HVAC SHAFT
HVAC SHAFT
CLASSROOM 1
CLASSROOM 2
HVAC SHAFT
CORRIDOR
400H5
CORRIDOR
400H4
CONTROL
400H7
ST
UD
Y
LO
UN
GE
0H
5'
- 3
6"
5'
- 7
3/ 4"
1'-3"
401/2
402/1
402/2
400H7/1
401/1
1'-8"
2'-0"
HOLD
7'-6" 4'-8" +/-
H3C3a
H3a
H3
C3a
C3a
H3a
4'-
" 1'- 3"
1'- 3"
'-1
1"
1'- 3"
1.3
1.3
H3
H3
1.3
2.5
2.5 2.5
2.5
2.5
2.5
2.5
1.2
STORAGE
DATA
RACKS
401/3
C3a
M2
C3a
C3a
1.5
1.5
1.5
1.5
5'-
3/ 8"
3'- 5"
4 7 /8"
'-3
4 7
/8"
'-7 1/
4"
10 3/16"
1.5
1.7
1.7
1.7
1.7
B C D E F G
5.2
B.3 B.9 C.3 D.3D.4 H
JOURNALISM LAB
JOURNALISM LAB
CORRIDOR
400H4
PASSAGE
400H7
GEOGRAPHY LAB
GEOGRAPHY SEMINAR RM
PASSAGE
400H8
GEOGRAPHY LAB
CORRIDOR
400H5
STAIR 4
400S4
ELEC
E415
GEOGRAPHY
TOWN SQUARE
414P
PASSAGE
414 A
GRADUATE
414 S
DISPLAY
414 R
GRADUATE
414 Q
PLANNING STUDIO
GEOGRAPHY
FACULTY OFFICE
414O
GEOGRAPHY
FACULTY OFFICE
414N
GEOGRAPHY
FACULTY OFFICE
414M
GEOGRAPHY
FACULTY OFFICE
414L
GEOGRAPHY
FACULTY OFFICE
414K
GEOGRAPHY
FACULTY OFFICE
414J
STORAGE
414T
CORRIDOR
414U
STAIR 5
400S5
GEOGRAPHY
FACULTY OFFICE
414I
GEOGRAPHY
FACULTY OFFICE
414H
GEOGRAPHY
DEPT CHAIR OFFICE
414G
GEOGRAPHY
FACULTY OFFICE
414F
GEOGRAPHY
FACULTY OFFICE
414E
GEOGRAPHY
FACULTY OFFICE
414D
GEOGRAPHY
FACULTY OFFICE
414C
GEOGRAPHY
FACULTY OFFICE
414B
HVAC SHAFT
HVAC SHAFT
1.1B
1.1C 1.2A 1.4A
1.4B
1.4B
2.1A
2.2B
4.1A 7.1
7.4
1.1C
1.1C
2.2B2.2B
2.2B2.2B
2.2B
2.2B
4.4B4.4B 4.4B 4.4B 4.4B 4.4B4.4B4.4B4.4B
4.4B 4.4B 4.4B 4.4B 4.4B 4.4B 4.4B
4.4B
4.4B
2.1A
1.1C 2.1A 1.1C 2.1A1.1C 2.1A1.1C 2.1A1.1C 2.1A1.1C 2.1A
1.1C 2.1A 1.1C 2.1A 1.1C 2.1A 1.1C 2.1A 1.1C 2.1A 1.1C 2.1A
1.1C 2.1A
1.1C 2.1A
1.2A
1.2A
1.1C
1.4A 1.2B
2.2A
1.1C 2.1A
1.1C 2.1A
1.4B
1.1C 2.1A
1.4B
1.1C 2.1A
7.5
4.4B
4.4B
4.4B
4.4B
4.4B
4.4B
2.2A
2.2A
2.2B
1.4A 1.4B
2.1A
1.4B2.1A
2.1A
2.1A
2.1A
2.1A
4.7B 4.7A
2.2B
2.2B
4.1C
1.1C
1.1D
1.1E
EXISTING TILE
FLOOR TO REMAIN
EX413/2
EX411/1
EX411/2
4.1B
2.2A
1.1D
1.1C
1.1C
1.2A
1.1C 1.2A
1.2A
1.2B
1.2A
1.2A
1.2A
1.2A 1.2A 1.2A 1.2A 1.2A 1.2A
1.2A1.2A 1.2A 1.2A
1.2A
1.2A
1.2A
1.1C 1.2A 1.2A1.2A
1.2A
1.2A
1.2A 1.4B
1.4A
1.4A
1.4A 1.4A 1.4A 1.4A 1.4A
1.4A
1.4A
1.4A1.4A1.4A1.4A1.4A1.4A
1.4A
1.4B
EXG APC CLG
IN CORRIDOR
TO REMAIN
1.2B
1.2A
1.2A
1.2B
1.2A
1.2A
1.2A
1.4B
1.4B
1.2A
1.4E
1.4E
1.2A
EXG APC CLG
IN CORRIDOR
TO REMAIN
2.2B
EX413/1
EX414T
EXISTING ROOM NUMBER KEY
"E-126" - "E" Denotes existing rooms "126" Denotes room numbers assigned for field survey
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
THE DEMOLITION PLANS ARE SCHEMATIC AND SHALL SERVE AS A
GENERAL GUIDE AND ARE NOT INTENDED TO BE TOTALLY INCLUSIVE.
CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL EXISTING
CONDITIONS.
COORDINATE DEMOLITION ACTIVITIES WITH ALL OTHER
CONSTRUCTION IDENTIFIED ON CONSTRUCTION DOCUMENTS.
ITEMS SHOWN DASHED ON THE DEMOLITION PLANS SHALL BE
REMOVED, TYPICAL, UNO. KEYNOTES / ARROWS POINT TO A
REPRESENTATIVE AMOUNT OF THE DEMOLITION WORK BUT ARE NOT
INTENDED TO BE ALL INCLUSIVE.
THE FOLLOWING APPLIES TO MASONRY WALLS IDENTIFIED TO BE
REMOVED:
IF WALL RESTS ON FLOOR SLAB, SCRAPE FLOOR CLEAN TO RECEIVE
NEW FINISH FLOORING. IF WALL EXTENDS BELOW FLOOR SLAB,
REMOVE WALL TO 8" BELOW FLOOR SURFACE AND PATCH FLOOR
TO MATCH ADJACENT SURFACES UNO.
NOTE: FLOOR SLAB ELEVATIONS MAY VARY ON EACH SIDE OF
WALL. G.C. SHALL PATCH / FILL FLOOR SURFACES TO OBTAIN A
MAXIMUM 1/8" PER FOOT SLOPE BETWEEN FLOOR SURFACES.
LINTELS SHALL BE INSTALLED IN NEW OPENINGS IN EXISTING
MASONRY WALLS. SEE STRUCTURAL DRAWINGS FOR SIZES.
REFER TO PHASING PLANS FOR THE SEQUENCE OR PHASE OF
SELECTED DEMO OPERATIONS.
REFER TO SPEC SECTION DIVISION 01 "SELECTIVE DEMOLITION" FOR
SPECIFIC REQUIREMENTS REGARDING DEMOLITION SHOWN ON THIS
DRAWING.
REFER TO SPEC SECTION DIVISION 01 "CUTTING AND PATCHING" FOR
SPECIFIC REQUIREMENTS REGARDING CUTTING AND PATCHING
SHOWN ON THIS DRAWING.
REMOVE ALL TACKBOARDS, MARKERBOARDS, AND/OR CHALKBOARDS
AND MASTIC, UNO.
REMOVE ALL SIGNAGE & RETAIN FOR REUSE.
C
0 W as hin gto n R oa d, Pi tts bu rg h, PA
2.5
.71 ww w.
DR
AW
co lle cti ve
.co m
RE
VI
SI
ON
S
Au tod es k D oc s:/
/U
-2 5-
IU
P Le on ar d H all
T em p C
OM
S pa ce s/U
-2
5-
Le on ar d H all R
.rv t
/22 /20
6:
:31
P M
A1
FO
UR
TH
F
LO
OR
D
EM
O
AN
D
FL
OO
R
PL
AN
LE
ON
AR
D
HA
LL
T
EM
P
CO
M
CL
AS
SR
M
RE
NO
VA
TI
ON
IN
DI
AN
A
UN
IV
ER
SI
TY
O
F
PE
NN
SY
LV
AN
IA
R
OB
ER
TS
HA
W B
UI
LD
IN
G
S
OU
TH
TH
IR
TE
EN
TH
AN
A, P
A, 1 G
RA
NT
S
TR
AN
A, P
A, Pr oj
No . U
-2
5-
Iss ue
D ate
2/2
2/2
CO
PY
RI
GH
T
25A101
FOURTH FLOOR PLAN
1/8" = 1'-0"
CONSTRUCTION NOTES
NUM DESCRIPTION
1.2 PROTECT EXISTING FLOOR FINISH DURING CONSTRUCTION
1.3 ALIGN FINISH FACES
1.5 EXISTING WALL TO ACHIEVE 1 HR FIRE BARRIER RATING. VERIFY FULL EXTENTS OF
WALL (FLOOR TO DECK) AND PATCH ANY OPENINGS TO MAINTAIN UL #U419
ASSEMBLY REQUIREMENTS
1.7 EXISTING RATED WALL/PARTITION/SHAFT - MAINTAIN RATING
2.5 PROVIDE BLOCKING FOR WALL-MOUNTED TV; SEE ELEV FOR HEIGHT
A101
FOURTH FLOOR DEMO PLAN
1/8" = 1'-0"
GENERAL DEMOLITION NOTES
DEMOLITION NOTES
NUM DESCRIPTION
1.1B REMOVE LINOLEUM SHEET FLOORING & MASTIC; PREP FOR NEW FLOOR
1.1C REMOVE CARPET/CARPET TILE & MASTIC; PREP FOR NEW FLOOR
1.1D REMOVE QUARRY TILE/CERAMIC TILE/TERRAZZO TILE & SETTING BED DOWN TO
EXISTING FLOOR SLAB; PREP FOR NEW FLOOR
1.1E EXISTING FLOORING AND BASE TO REMAIN - PROTECT DURING DEMO
1.2A REMOVE RUBBER BASE & MASTIC
1.2B REMOVE RUBBER BASE & MASTIC - SALVAGE BASE FOR REUSE; PREP WALL FOR
BASE REINSTALL
1.4A REMOVE ACOUSTIC PANEL CEILING & SYSPENSION SYSTEM, GRILLES, DIFFUSERS,
& LIGHTING
1.4B REMOVE PLASTER/GYP BOARD CEILING/BULKHEAD & SYSPENSION
SYSTEM/FRAMING
1.4E EXG PLASTER/GYP BOARD CEILING/BULKHEAD & SYSPENSION SYSTEM/FRAMING
TO REMAIN
2.1A REMOVE GPBD & STUD PARTITION
2.2A REMOVE DOOR(S), FRAME, AND FLOOR/WALL STOPS WHERE PRESENT -
SALAVAGE WOOD DOORS, FRAME HARDWARE & TRIM FOR REUSE
2.2B REMOVE DOOR(S), FRAME, AND FLOOR/WALL STOPS WHERE PRESENT
4.1A REMOVE PLASTIC LAMINATE/ WOOD/ METAL CASEWORK, COUNTERTOPS,
BLOCKING & ASSOCIATED SUPPORTS - SALVAGE AND RETAIN FOR REUSE
4.1B REMOVE PLASTIC LAMINATE/ WOOD/ METAL CASEWORK, COUNTERTOPS,
BLOCKING & ASSOCIATED SUPPORTS
4.1C REMOVE WALL MOUNTED ACCESSORIES--PAPER TOWEL DISP, SOAP DISP,
ETC--AND SALVAGE FOR REUSE
4.4B REMOVE WINDOW TREATMENTS AND RETAIN FOR REINSTALLATION
4.7A REMOVE CEILING CAMERAS, MICROPHONES, SPEAKERS, PROJECTORS, & OTHER
AV EQUIP & TECH; SALVAGE FOR REUSE
4.7B REMOVE TOILET ACCESSORIES INCL'D TOILET PAPER, PAPER TOWEL, SOAP,
SANITARY DISPENSORS, WASTE & SANITARY DISPOSAL, MIRRORS, AND HOOKS
7.1 REMOVE PLUMBING FIXTURES
7.4 REMOVE KITCHEN EQUIPMENT
7.5 REMOVE WATER FOUNTAINS AND RETAIN FOR REINSTALLATION
UP
EXISTING ROOM NUMBER KEY
"E-126" - "E" Denotes existing rooms "126" Denotes room numbers assigned for field survey
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
THE DEMOLITION PLANS ARE SCHEMATIC AND SHALL SERVE AS A
GENERAL GUIDE AND ARE NOT INTENDED TO BE TOTALLY INCLUSIVE.
CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL EXISTING
CONDITIONS.
COORDINATE DEMOLITION ACTIVITIES WITH ALL OTHER
CONSTRUCTION IDENTIFIED ON CONSTRUCTION DOCUMENTS.
ITEMS SHOWN DASHED ON THE DEMOLITION PLANS SHALL BE
REMOVED, TYPICAL, UNO. KEYNOTES / ARROWS POINT TO A
REPRESENTATIVE AMOUNT OF THE DEMOLITION WORK BUT ARE NOT
INTENDED TO BE ALL INCLUSIVE.
THE FOLLOWING APPLIES TO MASONRY WALLS IDENTIFIED TO BE
REMOVED:
IF WALL RESTS ON FLOOR SLAB, SCRAPE FLOOR CLEAN TO RECEIVE
NEW FINISH FLOORING. IF WALL EXTENDS BELOW FLOOR SLAB,
REMOVE WALL TO 8" BELOW FLOOR SURFACE AND PATCH FLOOR
TO MATCH ADJACENT SURFACES UNO.
NOTE: FLOOR SLAB ELEVATIONS MAY VARY ON EACH SIDE OF
WALL. G.C. SHALL PATCH / FILL FLOOR SURFACES TO OBTAIN A
MAXIMUM 1/8" PER FOOT SLOPE BETWEEN FLOOR SURFACES.
LINTELS SHALL BE INSTALLED IN NEW OPENINGS IN EXISTING
MASONRY WALLS. SEE STRUCTURAL DRAWINGS FOR SIZES.
REFER TO PHASING PLANS FOR THE SEQUENCE OR PHASE OF
SELECTED DEMO OPERATIONS.
REFER TO SPEC SECTION DIVISION 01 "SELECTIVE DEMOLITION" FOR
SPECIFIC REQUIREMENTS REGARDING DEMOLITION SHOWN ON THIS
DRAWING.
REFER TO SPEC SECTION DIVISION 01 "CUTTING AND PATCHING" FOR
SPECIFIC REQUIREMENTS REGARDING CUTTING AND PATCHING
SHOWN ON THIS DRAWING.
REMOVE ALL TACKBOARDS, MARKERBOARDS, AND/OR CHALKBOARDS
AND MASTIC, UNO.
REMOVE ALL SIGNAGE & RETAIN FOR REUSE.
F G
CHAIR OFFICE
508NN
ADMIN OFFICE
508OO
STAIR 5
500S5
STOR
508FF
OFFICE
508PP
OFFICE
508QQ
OFFICE
508RR
OFFICE
508KK
OFFICE
508LL
OFFICE
508MM
CORRIDOR
508EE
M2
6'-2"
2'- 6"
1.5
DUCTS - SEE HVAC DRAWINGS
SHAFT ENCLOSURE - COORDINATE
LAYOUT AND SIZE WITH DUCT LOCATION
AND MINIMIZE SIZE IN OFFICE
EXISTING SHAFT ENCLOSURE -
MAINTAIN RATING
1 HOUR RATED SHAFT
ENCLOSURE CONNECTING
FOURTH FLOOR TO ROOF
F G
ROOFTOP MECHANICAL UNIT -
SEE HVAC DRAWINGS
SET CURB AND FLASH TO EXSITING
ROOFTOP MEMBRANE PER
MANUFACTURERS REQUIREMENTS TO
MAINTAIN ALL WARRANTY COVERAGE
F G
CHAIR OFFICE
508NN
ADMIN OFFICE
508OO
STAIR 5
500S5
STOR
508FF
OFFICE
508PP
OFFICE
508QQ
OFFICE
508RR
OFFICE
508KK
OFFICE
508LL
OFFICE
508MM
CORRIDOR
508EE
3.8
1.
A.
B.
C.
D.
2.
A.
B.
CODES AND STANDARDS
New construction has been designed to, and shall be constructed in accordance with the following building codes and standards:
Pennsylvania Uniform Construction Code 2018 International Building Code (IBC 2018) 2018 International Existing Building Code (IEBC 2018) ASCE 7-16, Minimum Design Loads and Associated Criteria for Buildings and Other Structures
Unless explicitly modified in the Contract Drawings and Specifications, the Contractor shall comply with provisions of:
AISC 360-16, Specification for Structural Steel Buildings AWS D1.1-15, Structural Welding Code - Steel
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
GENERAL
New construction shall comply with the Contract Documents and the Building Code.
Do not start work without appropriate permits from Authority Having Jurisdiction (AHJ).
Drawings are not to be scaled.
Typical details and general notes apply to all parts of the work except where specifically detailed or unless otherwise noted.
The structural drawings illustrate structural members. Refer to Contract Documents for non-structural items which require coordination with structural members.
No items shall be embedded into structural members unless shown on the structural drawings or approved by the Structural Engineer of Record (SEoR).
No structural elements shall be cut unless specifically approved by the SEoR.
Sleeves and openings shall be located in a manner that will maintain structural integrity of the element.
The Contractor shall verify and be responsible for dimensions and conditions which impact the work. Field verify sizes, elevations, hole locations, etc., prior to fabrication.
The Contractor shall carefully review the drawings to identify the scope of work required, visit the site to relate the scope of work to existing conditions and determine the extent to which those conditions and physical surroundings will impact the work.
The Contractor shall resolve any conflicts on the drawings or in the specifications with the design team before proceeding with the work.
Any deviation, modification, or substitution from the approved set of structural documents shall be submitted to the Owner and design team for review/approval prior to its use or inclusion on the shop drawings.
The Contractor shall review shop drawings for completeness and compliance with Contract Documents and stamp shop drawings prior to submission to the design team.
Review of the shop drawings by the design team shall not be construed as an authorization to deviate from the Contract Documents.
Shop drawings will not be processed if incomplete, lack coordination with relevant portion of Contract Documents, lack calculations if required, or if deviations, modifications, and substitutions are indicated without prior written approval from the Architect/SEoR.
The Contractor's Engineers and the Delegated Design Engineers hired by the Contractor shall be Professional Engineers licensed in the jurisdiction where the project is located.
1.
A.
B.
C.
2.
3.
4.
A.
B.
C.
5.
6.
7.
A.
a.
b.
c.
d.
B.
a.
b.
c.
C.
8.
9.
A.
B.
10.
11.
12.
A.
B.
C.
STRUCTURAL STEEL CONSTRUCTION
Structural steel detailing, fabrication, and erection shall conform to:
AISC 303, Code of Standard Practice for Steel Buildings and Bridges.
RCSC's Specification for Structural Joints Using High-Strength Bolts.
AWS D1.1, Structural Welding Code.
Fabricator shall be an AISC-Certified Plant, Category BU.
Erector shall be an AISC-Certified Erector, Category CSE.
Structural Steel shall meet the following:
W, WT, C, and MC shapes per ASTM A992, Grade 50.
M, S, and L shapes per ASTM A572, Grade 50.
Plates and bars per ASTM A572, Grade 50.
The full design and load-carrying capacity of the steel shall not be impaired due to fabrication, shipment, or erection procedures. Throughout the complete process, the stability of individual members and assemblies shall be maintained.
See Construction Documents for miscellaneous steel requirements.
Connections - high--strength bolted or welded:
Bolted Connections:
Bolts shall meet ASTM F3125, with ASTM F436 hardened washers and ASTM A563 nuts.
Provide bearing type connections with thread included in the shear plane for connections other than slip critical connections.
Bolts shall be tightened to full pretensioning load, except slip connections and other connections noted shall be snug tight.
Use standard holes with the following exceptions: oversize holes are permitted when bolts are loaded in tension; short slotted holes are permitted for shear loading perpendicular to the slot.
Welded Connections:
Welding electrodes shall be E70XX except where other electrodes are required for compatibility with material being welded.
Where minimum AISC fillet weld thickness requirement exceeds welds shown on details, or weld size is not specified, provide minimum AISC weld.
All shop and field welding shall be performed by a welder with current valid certificate in the type of weld specified.
Copes and cut openings where specified shall have a 1/2" radius minimum.
Grout under base plates and bearing plates shall be non-metallic, non-shrink grout conforming to ASTM C1107.
Protective coatings, unless otherwise noted:
Prepare surfaces of interior steel not exposed to view to SSPC-SP 2; exterior steel and interior steel exposed to view to SSPC-SP 6/NACE No. 3.
Interior steel: Provide chemically active, modified alkyd primer at 1.5 mils dry thickness.
Provide 1/4" closure plates at open ends of HSS members.
Miscellaneous hanging loads such as stair stringers, pipes, mechanical units, etc., supported by steel members shall be applied in such a manner that no torsional forces are induced in the steel members, i.e., loads shall pass through the centerline of wide flange sections and through the shear center of channels.
Submittals shall include:
Product data, mill test reports, and material certificates for all materials.
Embedment drawings with details and locations of each embedment.
Shop drawings with erection drawings, details of cuts, connections, splices, camber, holes, bolts, welds, coatings, and other pertinent data.
1.
2.
3.
A.
B.
4.
STRUCTURAL TESTING AND SPECIAL INSPECTIONS
Structural testing and special inspections are required and shall include items outlined in Chapter 17 of the Building Code. The Owner shall engage a qualified independent testing agency to conduct structural testing and special inspections.
Special inspectors shall be employed or retained by the approved testing agency and have the recommended experience and certifications as summarized in Appendix C of the current International Code Counsel (ICC) Special Inspection Manual. The testing agency may employ or retain multiple special inspectors with differing areas of expertise as required for the project.
Structural observations performed by the Architect/SEoR during construction:
Are not special inspection services and do not waive the responsibility for the inspections required by the AHJ or the testing agency.
Do not guarantee the Contractor's performance and shall not be considered as supervision of construction.
The qualified testing agency shall submit a written summary statement indicating that applicable structural testing and special inspections have been completed. The written summary statement shall clearly identify non-compliant test and inspection results. The written summary statement shall be sealed by the testing agencies supervising Professional Engineer and be submitted to the Owner, Contractor, building official, and design professionals.
C8x11.5 (2 SIDES)
3/8" STIFFENER PLATE
(EA. CORNER)
TOP OF ANGLE/CHANNEL
FRAME TO BE FLUSH
WITH TOP OF JOIST
OR BEAM
EX. STEEL BEAM
NOTES:
1. IF "X" IS 4" OR LESS, ELIMINATE ANGLE
PARALLEL TO JOIST OR BEAM.
2. CONTRACTOR TO VERIFY SIZE AND
LOCATION OF ALL OPENINGS. SEE
ARCHITECTURAL, MECHANICAL, ETC.
DRAWINGS FOR OPENINGS NOT
SHOWN ON STRUCTURAL DRAWINGS.
3. CUT HOLE IN ROOF/FLOOR DECK AFTER
INSTALLATION OF ALL FRAME MEMBERS
OPENING
"X"
OP
EN
PLAN
SECTION A-A
ROOF/FLOOR DECK OPENING DETAIL
A-A
1/4
2 SIDES
8'-0" MAX.
L4x4x1/2 (2 SIDES)
3' -0
" M
AX
1/4
2 SIDES
ROOF DECK
(SEE PLAN)
STEEL BEAM OR
JOIST (SEE PLAN)
NOTE:
COORDINATE MECHANICAL UNIT
LOCATION AND SUPPORT STRUCTURE
WITH EQUIPMENT SUPPLIER
COORDINATE ROOFING
WITH ARCHITECTURAL
DRAWINGS
MC6x12 CONTINUOUS
CHANNEL SUPPORT
MECHANICAL UNIT.
COORDINATE W/ ARCH.
AND MECH. DWGS.
MECHANICAL UNIT SUPPORT OVER STEEL DECK
3/16 2
EACH SIDE OF
CHANNEL AT BEAM
OR JOIST
C
0 W as hin gto n R oa d, Pi tts bu rg h, PA
2.5
.71 ww w.
DR
AW
co lle cti ve
.co m
RE
VI
SI
ON
S
Au tod es k D oc s:/
/U
-2 5-
IU
P Le on ar d H all
T em p C
OM
S pa ce s/U
-2
5-
Le on ar d H all R
.rv t
/22 /20
6:
:32
P M
A1
FI
FT
H
FL
OO
R
RO
OF
P
LA
N
LE
ON
AR
D
HA
LL
T
EM
P
CO
M
CL
AS
SR
M
RE
NO
VA
TI
ON
IN
DI
AN
A
UN
IV
ER
SI
TY
O
F
PE
NN
SY
LV
AN
IA
R
OB
ER
TS
HA
W B
UI
LD
IN
G
S
OU
TH
TH
IR
TE
EN
TH
AN
A, P
A, 1 G
RA
NT
S
TR
AN
A, P
A, Pr oj
No . U
-2
5-
Iss ue
D ate
2/2
2/2
CO
PY
RI
GH
T
CONSTRUCTION NOTES
NUM DESCRIPTION
1.2 PROTECT EXISTING FLOOR FINISH DURING CONSTRUCTION
1.3 ALIGN FINISH FACES
1.5 EXISTING WALL TO ACHIEVE 1 HR FIRE BARRIER RATING. VERIFY FULL EXTENTS OF
WALL (FLOOR TO DECK) AND PATCH ANY OPENINGS TO MAINTAIN UL #U419
ASSEMBLY REQUIREMENTS
1.7 EXISTING RATED WALL/PARTITION/SHAFT - MAINTAIN RATING
2.5 PROVIDE BLOCKING FOR WALL-MOUNTED TV; SEE ELEV FOR HEIGHT
GENERAL DEMOLITION NOTES
A102
FIFTH FLOOR - SHAFT ENCLOSURE
1/8" = 1'-0"
A102
ROOF - NEW HVAC
1/8" = 1'-0"
A102
FIFTH FLOOR - SHAFT ENCLOSURE DEMO
1/8" = 1'-0"
DEMOLITION NOTES
NUM DESCRIPTION
3.8 CUT OPENING IN IN FLOOR FOR NEW HVAC - SEE MEP DWGS
GENERAL NOTES - STRUCTURAL
4.
5.
A.
B.
6.
7.
8.
9.
10.
11.
12.
13.
14.
1. HM DOOR FRAMES TO MATCH WALL PAINT
2. DOOR FINISH AND WOOD TO MATCH EXISTING DOORS
3. INSTALL BACKER ROD AND SEALANT IN COLOR AS SELECTED BY
ARCHITECT -- FULL PERIMETER OF FRAME, BOTH SIDES.
INSTALL HINGE SIDE OF ALL DOOR FRAMES MINIMUM 4" FROM
ADJACENT OR PERPENDICULAR WALL UNLESS NOTED OR
DIMENSIONED OTHERWISE.
MAINTAIN CLEARANCES AT LATCH EDGE OF ALL DOORS IN
OCCUPIED SPACES AS FOLLOWS:
PULL SIDE MINIMUM 18" CLEAR
PUSH SIDE MINIMUM 12" CLEAR
REPORT CONDITIONS WHICH DO NOT MEET THESE
REQUIREMENTS TO ARCHITECT.
ALL HOLLOW METAL FRAMES REQUIRING FACE ANCHORS SHALL
BE FILED, SANDED, AND PRIMED IN FIELD PRIOR TO FINAL
PAINTING.
ALL HOLLOW METAL WINDOWS AND DOOR FRAMES SHALL BE
FULLY WELDED CONSTRUCTION. ALL HOLLOW METAL FRAME
WELDS SHALL BE GROUND SMOOTH, PRIMED, AND READY FOR
FINAL PAINT IN FIELD UNLESS NOTED OTHERWISE.
APPLIED STOPS SHALL BE ON INTERIOR/LOCKED (ROOM OR
BUILDING) SIDE OF HOLLOW METAL FRAME - TYPICAL.
GROUT ALL HM DOOR FRAMES FULL IN MASONRY WALLS.
REINFORCE FRAMES IN STUD WALLS IN ACCORDANCE WITH
"TYPICAL STEEL STUD JAMB DETAILS /ELEVATIONS".
ALL RATED OPENINGS SHALL HAVE MATCHING RATED FRAMES,
AND HAVE UL LISTED DOOR HARDWARE. LABELED TAGS SHALL
NOT BE PAINTED.
WHERE ALUMINUM FRAMING IS ABUTTING DISSIMILAR METALS,
APPLY BITUMINOUS PAINT TO SURFACES OF BOTH ADJOINING
METALS.
Existing construction door notes
GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS AND DIMENSIONS.
ALL EXISTING INTERIOR, AND EXTERIOR HOLLOW METAL DOOR
FRAMES TO REMAIN, ARE TO BE REPAINTED.
REPAIR EXISTING HOLLOW METAL FRAMES TO REMAIN WHERE
HINGES, DEADBOLTS, OR OTHER HARDWARE IS REMOVED WITH
STEEL PLATES. PREP, GRIND SMOOTH, THEN SAND AREAS TO
RECEIVE FIELD PAINTING.
TYP INTERIOR UNO
- 1/4" TEMPERED GLASS
INTERIOR FIRE PROTECTED
CERAMIC GLASS
- 2.2 - 45 MINUTES
F (FLUSH)
- MATERIAL VARIES,
SEE DOOR SCHEDULE
SE
E
SC
HE
D
SEE SCHED
HM-1
AS
SCHEDULUED
AS
S
CH
ED
UL
ED
2"
2" 2"
AS
SCHEDULUED
AS
S
CH
ED
UL
ED
2"
2" 1'-11" 2"
HM-2
AS
SCHEDULED
AS
S
CH
ED
UL
ED
2"
2" 1'-6" 2"
HM-3
GLGL
2.2 2.2
DOOR HARDWARE SET TYPES LISTED TO INDICATE DOOR OPERATION AND ANY SPECIAL
CONDITIONS FOR THE DOOR TYPE.
FOR EACH HARDWARE SET TYPE, PROVIDE ALL REQUIRED DOOR HARDWARE FOR A FULLY
FUNCTIONAL DOOR - INCLUDING LATCH SETS, LEVERS, HINGES, CLOSERS, LOCK AND LATCH
STRIKES, DOOR STOPS, GASKETING AND TRIM, ETC.
DOOR HARDWARE MAKE, MODEL, STYLE, AND FINISHES TO MATCH EXISTING SCHOOL STANDARDS.
1.
2.
3.
4.
SET NO. FUNCTION/STYLE LATCH SET DETAILS NOTES
CLASSROOM FUNCTION EXG LEVERS & COMBINATION LOCK INCLUDE WALL STOP
INCLUDE PANIC HARDWARE
NO LONGER USED
OFFICE FUNCTION EXG LEVERS & COMBINATION LOCK INCLUDE WALL STOP
STORAGE FUNCTION USE EXG LEVERS INCLUDE WALL STOP
C
0 W as hin gto n R oa d, Pi tts bu rg h, PA
2.5
.71 ww w.
DR
AW
co lle cti ve
.co m
RE
VI
SI
ON
S
Au tod es k D oc s:/
/U
-2 5-
IU
P Le on ar d H all
T em p C
OM
S pa ce s/U
-2
5-
Le on ar d H all R
.rv t
/22 /20
6:
:33
P M
A6
DO
OR
S
CH
ED
UL
ES
, D
OO
R
AN
D
FR
AM
E
TY
PE
S
LE
ON
AR
D
HA
LL
T
EM
P
CO
M
CL
AS
SR
M
RE
NO
VA
TI
ON
IN
DI
AN
A
UN
IV
ER
SI
TY
O
F
PE
NN
SY
LV
AN
IA
R
OB
ER
TS
HA
W B
UI
LD
IN
G
S
OU
TH
TH
IR
TE
EN
TH
AN
A, P
A, 1 G
RA
NT
S
TR
AN
A, P
A, Pr oj
No . U
-2
5-
Iss ue
D ate
2/2
2/2
CO
PY
RI
GH
T
DOOR SCHEDULE - FOURTH FLOOR
NUM
PANEL SIZE PANEL FRAME
RATING
HDW SET
NO. REMARKS COMMENTSWIDTH HEIGHT THICK MATL TYPE GLAZ MATL TYPE GLAZ
400H7/1 3' - 0" 7'-0" 1 3/4" WD F - HM HM-1 - - 3 REINSTALL SALVAGED DOOR & FRAME EX414T/1
401/1 3' - 0" 7'-0" 1 3/4" WD F - HM HM-3 2.2 45 1 REINSTALL SALVAGED DOOR & FRAME EX413/1, PROVIDE CLOSER &
PANIC HARDWARE
401/2 3' - 0" 7'-0" 1 3/4" WD F - HM HM-1 - - 4 PAINT FRAME TO MATCH WALL COLOR
401/3 3' - 0" 7'-0" 1 3/4" WD F - HM HM-3 2.2 45 1 EXG DOOR TO REMAIN IN PLACE, PROVIDE CLOSER & PANIC
HARDWARE
402/1 3' - 0" 7'-0" 1 3/4" WD F - HM HM-2 2.2 45 1 REINSTALL SALVAGED DOOR & FRAME EX411/1, PROVIDE CLOSER &
PANIC HARDWARE
402/2 3' - 0" 7'-0" 1 3/4" WD F - HM HM-2 2.2 45 1 REINSTALL SALVAGED DOOR & FRAME EX411/2, PROVIDE CLOSER &
PANIC HARDWARE
GENERAL DOOR NOTESGLAZING LEGEND
DOOR TYPESDOOR FRAME TYPES
DOOR HARDWARE NOTES
EXISTING DOORS TO BE REUSED
NUM
PANEL SIZE PANEL FRAME
RATING
HDW SET
NO. REMARKS COMMENTSWIDTH HEIGHT THICK MATL TYPE
GLA
Z MATL TYPE GLAZ
EX411/1 3' - 0" 7'-0" 1 3/4" WD F - HM HM-2 2.2 45 REUSE FOR 402/1
EX411/2 3' - 0" 7'-0" 1 3/4" WD F - HM HM-2 2.2 45 REUSE FOR 402/2
EX413/1 3' - 0" 7'-0" 1 3/4" WD F - HM HM-3 2.2 45 EXG DOOR & FRAME TO REMAIN IN PLACE
EX413/2 3' - 0" 7'-0" 1 3/4" WD F - HM HM-3 2.2 45 REUSE FOR 401/1
EX414T 3' - 0" 7'-0" 1 3/4" WD F - HM HM-1 - - REUSE FOR 401/2
PROJ SCRN PROJ SCRN PROJ SCRN
PR
O
J
SC
R N
PR
O
J
SC
R N
1.
2.
3.
4.
5.
6.
GRILLES, DIFFUSERS, & SPRINKLER CAPS IN GPBD BULKHEADS
SHALL BE PAINTED TO MATCH BULKHEAD COLOR TYPE, EXCEPT
WHERE BULKHEAD IS WHITE.
PAINT ALL EXPOSED SURFACES - FACES AND UNDERSIDE OF GPBD
BULKHEADS AND CEILINGS COLOR PNT-2 UNO. PNT-X DESIGNATION
ON…