2-FraileyTwp ClarkSt SupplementalStructureDrawings.pdf
PDF 1 MB Posted
- Solicitation number
- Not on record
- Issued by
- Schuylkill County, Pennsylvania
About this file
These engineering design drawings, prepared by Contech Bridge Systems for Schuylkill County, Pennsylvania, detail the Clark Street (T-436) Bridge Replacement project over Good Spring Creek in Frailey Township. The preliminary technical documents outline a comprehensive bridge replacement plan involving precast concrete arch units, wingwalls, foundations, and associated infrastructure components. The project features a 20'-0" span bridge with a 5'-0" rise, designed to replace an existing bridge structure, with detailed specifications for installation, post-tensioning, joint sealing, and backfilling procedures.
The technical drawings specify precise construction requirements, including the use of precast reinforced concrete Express foundation units, granular subfooting, and specific backfill materials like #57 stone. The project involves detailed engineering specifications for excavation, concrete placement, structural assembly, and site preparation, with particular attention to compaction, grout application, and critical backfill zone management. The documents are marked as "PRELIMINARY NOT FOR CONSTRUCTION" and dated 12/11/2023, suggesting the plans are in the final design stage before actual construction bidding and implementation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
C
LAR
K STR
EET (T-436)
LOCATION PLAN
NOT TO SCALE
℄STRUCTUREFLOW
28'-6"
STA. 4+60.00
NOTES
GENERAL NOTES:
1. THIS BRIDGE HAS BEEN DESIGNED FOR GENERAL SITE CONDITIONS. THE
PROJECT ENGINEER SHALL BE RESPONSIBLE FOR THE STRUCTURE'S SUITABILITY
TO THE EXISTING SITE CONDITIONS AND FOR THE HYDRAULIC EVALUATION --
INCLUDING SCOUR AND CONFIRMATION OF SOIL CONDITIONS.
2. PRIOR TO CONSTRUCTION, CONTRACTOR MUST VERIFY ALL ELEVATIONS SHOWN
THROUGH THE ENGINEER.
3. ONLY CONTECH ENGINEERED SOLUTIONS LLC, THE CON/SPAN® APPROVED
PRECASTER IN PENNSYLVANIA MAY PROVIDE THE STRUCTURE DESIGNED IN
ACCORDANCE WITH THESE PLANS.
4. THE USE OF ANOTHER PRECAST STRUCTURE WITH THE DESIGN ASSUMPTIONS
USED FOR THE CON/SPAN® STRUCTURE MAY LEAD TO SERIOUS DESIGN ERRORS.
USE OF ANY OTHER PRECAST STRUCTURE WITH THIS DESIGN AND DRAWINGS
VOIDS ANY CERTIFICATION OF THIS DESIGN AND WARRANTY. CONTECH
ENGINEERED SOLUTIONS LLC ASSUMES NO LIABILITY FOR DESIGN OF ANY
ALTERNATE OR SIMILAR TYPE STRUCTURES.
5. ALTERNATE STRUCTURES MAY BE CONSIDERED, PROVIDED THAT DRAWINGS AND
CALCULATIONS SIGNED AND SEALED BY A PROFESSIONAL ENGINEER,
REGISTERED IN THE STATE OF PENNSYLVANIA, EMPLOYED BY THE PRECAST
CONCRETE BRIDGE SUPPLIER, ARE SUBMITTED TO THE ENGINEER 2 WEEKS
PRIOR TO THE BID DATE FOR REVIEW AND APPROVAL.
6. ALTERNATE STRUCTURES MAY BE CONSIDERED, PROVIDED THAT THE ALTERNATE
DESIGN DOES NOT REDUCE THE HYDRAULIC OPENING OF THE STRUCTURE AS
SHOWN ON THE DRAWINGS. AT A MINIMUM THE ALTERNATE STRUCTURE MUST
PROVIDE THE SAME OR LARGER SPAN AND RISE AS THE STRUCTURE SHOWN ON
THE DRAWINGS.
7. THE PRECAST ARCH SUPPLIER MUST ATTEND THE PRE-BID MEETING, IF ONE IS
HELD.
8. SUPPLIER OF PROPOSED ALTERNATES TO A CON/SPAN® BRIDGE SYSTEM MUST
SUBMIT AT LEAST TWO (2) INDEPENDENTLY VERIFIED FULL SCALE LOAD TESTS
THAT CONFIRM THE PROPOSED DESIGN METHODOLOGY OF THE THREE
SIDED/ARCH STRUCTURE(S). THE PROPOSED ALTERNATE, UPON SATISFACTORY
CONFIRMATION OF DESIGN METHODOLOGY, MAY BE CONSIDERED AN
ACCEPTABLE ALTERNATE.
9. PROPOSED ALTERNATE STRUCTURES MAY BE CONSIDERED, PROVIDED THAT THE
PRECAST CONCRETE BRIDGE STRUCTURES ARE PROVIDED BY A SUPPLIER THAT
HAS A MINIMUM OF TWO (2) REGISTERED PROFESSIONAL ENGINEERS ON STAFF
THAT ARE DEDICATED TO THE DESIGN OF THESE TYPES OF STRUCTURES.
SUPPLIER MUST PROVIDE THESE NAMES, P.E. LICENSE NUMBERS AND DATES OF
HIRE AT TIME OF ALTERNATE SUBMITTAL.
DESIGN DATA
DESIGN LOADING:
BRIDGE UNITS: PHL-93, P-82 & P2016-13
HEADWALLS: EARTH PRESSURE + LIVE LOAD SURCHARGE + LIVE LOAD IMPACT (TL-3)
WINGWALLS: EARTH PRESSURE + LIVE LOAD SURCHARGE
DESIGN FILL HEIGHT: 10" MIN. TO 1'-6" MAX.
FROM TOP OF CROWN TO TOP OF PAVEMENT.
DESIGN METHOD: LOAD AND RESISTANCE FACTOR DESIGN PER AASHTO LRFD BRIDGE DESIGN
SPECIFICATIONS, 9TH EDITION, 2020 AND PENNDOT STANDARDS.
ARCH FOUNDATION FACTORED BEARING PRESSURE: SERVICE I = 5760 PSF*, STRENGTH I = 7040 PSF* WINGWALL FOUNDATION FACTORED BEARING PRESSURE: SERVICE I = 4550 PSF*, STRENGTH I = 4790 PSF*
REFER TO SUMMARY TABLE PROVIDED BY BENESCH, DATED 8/29/2023.
*AT THE TIME OF DESIGN, A FULL GEOTECHNICAL REPORT FOR THE PROJECT SITE WAS NOT
AVAILABLE. IT IS THE PROJECT ENGINEER'S, OWNER'S AND/OR THE CONTRACTOR'S
RESPONSIBILITY TO VERIFY THAT THE ACTUAL SITE CONDITIONS AT THE TIME OF
CONSTRUCTION ARE CONSISTENT WITH THE ASSUMED ALLOWABLE SOIL BEARING
PRESSURE WITH A GEOTECHNICAL INVESTIGATION FROM A QUALIFIED GEOTECHNICAL
ENGINEER.
MATERIALS
PRECAST UNITS SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH CON/SPAN®
SPECIFICATIONS. PRECAST CONCRETE FOR EXPRESS FOUNDATIONS SHALL HAVE A MINIMUM
COMPRESSIVE STRENGTH OF 5000 PSI. CAST-IN-PLACE CONCRETE FOR FOUNDATIONS SHALL BE CLASS A AND HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 3000 PSI. REINFORCING STEEL FOR FOOTINGS
SHALL CONFORM TO ASTM A615 GRADE 60.
14°
KMH
TEK
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT1
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
9100 Centre Pointe Dr., Suite 400, West Chester, OH 45069
REVISION DESCRIPTIONDATEMARK BY
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
PRELIMINARY
NOT FOR CONSTRUCTION
CLARK STREET (T-436) BRIDGE REPLACEMENT
OVER GOOD SPRING CREEK
FRAILEY TOWNSHIP
SCHUYLKILL COUNTY, PENNSYLVANIA
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
OVER GOOD SPRING CREEK
FRAILEY TOWNSHIP
FILL LIFTING INSERT POCKET
WITH GROUT, FINISHING FLUSH
9" SQUARE PIECE
OF JOINT WRAP
PRECAST BRIDGE UNIT,
HEADWALL OR WINGWALL
LIFTING INSERT
TYPICAL LIFT INSERT SEALING DETAIL
NOT TO SCALE
PRIMER COMPATIBLE
WITH JOINT WRAP
TOP OF PRECAST
BRIDGE UNIT
3 - (B20) 20'-0" SPAN x 5'-0" RISE x 6'-1" LONG 2 - (B20) 20'-0" SPAN x 5'-0" RISE SKEWED
(2'-41 8" SHORT LEG x 7'-9" LONG LEG)
PRECAST CONCRETE BRIDGE UNITS
PLUS 4 JOINTS @ 12"± PER JOINT
℄STRUCTUREFLOW
N
SLO
PE
0 2' 4' 8'
BRIDGE PLAN
COVER ALL CORNERS AND
PEDESTAL JOINTS WITH
2'-0" WIDE STRIP OF
FILTER FABRIC
CCT6
E
CT8
DETAIL 4A
CT9
4B
CT9
SLO
PE
'-0
'-0
1'- 0"
'-0
WIN
G D
45°
7"
10"
TYPE C
3'- 0"2'-
6"
(TYP.)
5'- 0"
TYPE B
TYPE B
3'- 0"
5'- 0"
2'-4"
TYPE C
TYPE C
2'-11"
A C T4
1'-105 8"
7"
10"
1'-105 8"
7"
10"
1'- 0"
'-0
WIN
G B
45°
7"
10"
28'-6"
TYPE B
4"Ø PERFORATED BACKFILL DRAIN
SUPPLIED WITH ARCH AND WINGWALL (TYP.)
TYPE C
DETAIL 5A
CT9
5B
CT9
2'-41 8"
7'-9"
2'-41 8"
7'-9"
TYPE C
1'-6" ATTACHED
HEADWALL
1'-6" ATTACHED
HEADWALL
1'-0"
17'-0"
W
IN
G A
1'-0"
16'-0"
W
IN
G C
TYPE C
4'-8" 5'-6"
TYPE C
5'-0"
3'-7"
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT2
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
PRELIMINARY
NOT FOR CONSTRUCTION
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
'-1
0"
7' -6
" F O
O
TI
N G
N
7' -6
" F O
O
TI
N G
℄STRUCTUREFLOW
CCT6
E
CT8
DCT6
A C T4 B C T4
FOUNDATION PLAN
0 2' 4' 8'
T/FOOTING
ELEV. 885.40 (TYP.)
T/PEDESTAL
ELEV. 892.90 (TYP.)
STRUCTURE LIMITS
CAST IN PLACE CONCRETE VOLUME: 70.2 CUBIC
YARDS CONCRETE VOLUME IS ACTUAL REQUIRED
AMOUNT AND SHOULD BE INCREASED FOR
ANTICIPATED LEAKAGE, WASTE, ETC.
1" 1"
1' -5
1'
-1 " K
EY
W
AY
2'
-6 " P
ED
ES
TA
L
1" 1"1'
-5
1' -1
" K
EY
W
AY
2' -6
" P
ED
ES
TA
L
6" 6"
4' -4
2'
-8 " K
EY
W
AY
6" 6"
4' -4
2'
-8 " K
EY
W
AY
9' -5
9'
-5
'-3
3 8"
FOOTIN
G
'-8
" P
EDESTAL
11"
1"
1" 6'-11"
10'-0" FOOTING
2'-2" KEYWAY
2'-0" PEDESTAL
11"1"
1"
6'-11"
10'-0" FOOTING
2'-2" KEYWAY2'-0" PEDESTAL
11" 1"
1"
11" 1"
1"
6'-11"
10'-0" FOOTING
2'-2" KEYWAY
2'-0" PEDESTAL
17'-0 3
4 " FO
O
TIN
G
17'-1 1
4 " PED
ESTAL
1'-93
8" PEDESTAL
16'-0 3
4 " FO
O
TIN
G 16'-1 1
4 " PED
ESTAL
1'-93
8" PEDESTAL
'-3
3 8"
FOOTIN
G
'-8
" P
EDESTAL45°
8" PEDESTAL
8" PEDESTAL
6'-45 8"
6'-45 8"
15'-23
4" FOOTING
1'-0"
11'-23 4"
PEDESTAL
11'-23
4"
PEDESTAL
15'-23
4" FOOTING
33'-03
4" FOOTING
2"2'-31
4"
30'-6" PEDESTAL
2" JOINT
(TYP.)
1'-0"
(TYP.)
7'-111 2"
PEDESTAL
2" JOINT
(TYP.)
6'-11"
10'-0" FOOTING
1'-0"
STRUCTURE LIMITS
45°
DETAIL 3
CT5
DETAIL 2
CT5
2'-2" KEYWAY
2'-0" PEDESTAL
PROVIDE 3'-0" LAP SPLICE (#6 x 6'-9")
TOP & BOTTOM EITHER SIDE OF JOINT
FOR LONGITUDINAL #6 BAR IN C.I.P.
PORTION OF EXPRESS™ FOOTING
(TYP. 2 LOCATIONS)
PRECAST REINFORCED CONCRETE EXPRESS™ FOUNDATION NOTES:
1. PRECAST FOUNDATION UNITS SHALL BE CONSTRUCTED AND INSTALLED IN
ACCORDANCE WITH SPECIFICATIONS FOR MANUFACTURE AND
INSTALLATION OF CON/SPAN BRIDGE SYSTEMS.
2. PRECAST CONCRETE FOR EXPRESS FOUNDATIONS SHALL HAVE A
MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 5000 PSI. CAST-IN-PLACE
FOR FOUNDATIONS SHALL BE CLASS A AND HAVE A MINIMUM 28-DAY
COMPRESSIVE STRENGTH OF 3000 PSI. REINFORCING STEEL FOR
FOUNDATIONS SHALL CONFORM TO ASTM A615 GRADE 60.
3. PRECAST FOUNDATION UNITS SHALL BE SET ON A MINIMUM 4-INCH THICK
BASE LAYER OF COMPACTED GRANULAR MATERIAL THE FULL WIDTH OF
THE FOUNDATION.
4. COMPACTED BACKFILL MATERIAL MUST BE PLACED UP TO THE TOP OF
THE PRECAST FOUNDATION UNITS ON BOTH SIDES PRIOR TO PLACING
CAST-IN-PLACE CONCRETE PORTION OF FOUNDATIONS.
5. CONCRETE SURFACES WHICH CAST-IN-PLACE CONCRETE WILL BE PLACED
AGAINST SHALL BE CLEAN, FREE OF LAITANCE, DIRT, STANDING WATER
AND ANY OTHER MATERIAL THAT MAY IMPAIR THE BOND BETWEEN THE
PRECAST CONCRETE AND CAST-IN-PLACE CONCRETE.
6. CAST-IN-PLACE CONCRETE MIX USED TO FILL FOUNDATION SHALL BE
ABLE TO FLOW INTO PEDESTAL/ARCH LEG SHIM SPACE OR NON-SHRINK
GROUT SHALL BE PLACED UNDER PEDESTAL/ARCH LEG AT FOUNDATION
CROSS MEMBERS PRIOR TO PLACEMENT OF CAST-IN-PLACE PORTION OF
FOUNDATION.
7. IF THE AMBIENT TEMPERATURE AT THE TIME OF PLACEMENT OF
CAST-IN-PLACE CONCRETE IS ABOVE 90°F OR EXPECTED TO GO BELOW
35°F DURING THE CURE PERIOD, THE CONTRACTOR SHALL FOLLOW THE
REQUIREMENTS OF THE LATEST EDITION OF THE AASHTO LRFD BRIDGE
CONSTRUCTION SPECIFICATIONS, SECTION 8.6.2 HOT WEATHER
PROTECTION OR SECTION 8.6.4 COLD WEATHER PROTECTION.
8. FOUNDATION CONCRETE SHALL REACH ITS FULL DESIGN STRENGTH
BEFORE BACKFILLING OF PRECAST ARCH MAY COMMENCE.
9. CAST-IN-PLACE CONCRETE PORTION OF FOUNDATION IS TO BE PLACED
AFTER SETTING THE PRECAST PEDESTAL WALLS, BUT PRIOR TO SETTING
OF PRECAST ARCH UNITS. CAST-IN-PLACE CONCRETE SHALL REACH 2500
PSI. BEFORE SETTING PRECAST ARCH UNITS.
9. ORDER OF INSTALLATION:
9.1. SET ARCH UNIT EXPRESS FOOTINGS. MOST STEEL TO BE PRE-TIED AT
PRECASTER.
9.3. SET PRECAST WINGWALL FOOTINGS.
9.4. INSERT DOWEL-INS THROUGH ARCH UNIT EXPRESS FOOTINGS INTO
DOWEL BARS IN WINGWALL FOOTINGS AS REQUIRED.
9.5. PRECAST PEDESTAL WALLS SHALL BE SET ONTO UNIT EXPRESS
FOOTINGS AND BRACED PRIOR TO POURING FOUNDATION
CONCRETE.
9.6. POUR CAST-IN-PLACE CONCRETE IN EXPRESS FOUNDATIONS.
9.7. ONCE CAST-IN-PLACE CONCRETE CURES TO A MINIMUM
COMPRESSIVE STRENGTH OF 2500 PSI THE PEDESTAL BRACES CAN
BE REMOVED.
9.8. BACKFILL PEDESTAL (OPTIONAL).
9.9. SET ARCH UNITS AND WINGWALLS.
1'-6" CROSS
MEMBER
1'-6" CROSS
MEMBER
1'-6" CROSS
MEMBER
1'-6" CROSS
MEMBER
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT3
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
OVER GOOD SPRING CREEK
FRAILEY TOWNSHIP
AutoCAD SHX Text
FOOTING
STREAMBED
REINFORCING NOT
SHOWN FOR CLARITY
PRECAST
BRIDGE UNIT
0 2' 4' 8'
A
CT2
SECTION
(B20) 20'-0" SPAN
1' -6
M
AX
. F
IL
L
5' -0
R
IS
E
C
LE
AR
V
AR
IE
S
4" THICK GRANULAR
SUBFOOTING
3' -0
7'
-6
7'-6"
2'-6"
ROCK, CLASS R-8 CHOKED
W/ R-4 AND STREAMBED MATERIALS
(BY OTHERS)
4"Ø PERFORATED
BACKFILL DRAIN
SUPPLIED WITH ARCH
(TYP.)
DETAIL 1
CT4
4'-0"
(TYP.)
1.0 1.5
4' -0
M
IN
CONCRETE MIX USED TO FILL EXPRESS™
FOOTING MUST BE ABLE TO BE WORKED
UNDER PEDESTAL SPACE, OR NON SHRINK
GROUT USED UNDER PEDESTAL PRIOR TO
CIP PORTION OF EXPRESS™ FOOTING
PRECAST CONCRETE
SIDE WALL
SECTION B
CT3
PRECAST CONCRETE
CROSS MEMBER
0 1' 2' 4'
CONSTRUCTION
JOINT (TYP.) (OPTIONAL)
1" S
H
IM
3" K
EY
W
AY
7' -6
PRECAST
PEDESTAL
1" G
R O
U T
3" K
EY
W
AY
INSIDE FACE OF
PRECAST BRIDGE UNIT
3" 1'-5"
3' -0
SEE TYPICAL BRIDGE UNIT
GROUT DETAIL ON THIS SHEET NOTE:
FILL ENTIRE KEYWAY INCLUDING
NOMINAL 1" VOID BETWEEN BOTTOM OF
KEYWAY AND BOTTOM OF PRECAST
BRIDGE UNIT LEG WITH GROUT.
NOT TO SCALE
GROUT TO TOP
OF KEYWAY
INSIDE FACE OF
PRECAST BRIDGE UNIT
TYPICAL BRIDGE UNIT GROUT DETAIL 11
2" x 51
2"
KEYWAY (TYP.)
C.I.P. CONCRETE
PRECAST
CONCRETE
2' -1
0"
2"
3' -0
7'
-6
3" K
EY
W
AY
1" G
R O
U T
#6 x 6'-8" @ 6" IN BETWEEN
EACH CROSS MEMBER
BOTTOM ONLY
PRECAST
PEDESTAL
INSIDE FACE OF
PRECAST BRIDGE UNIT
#6 x 6'-8" @ 1'-0" IN BETWEEN
EACH CROSS MEMBER
TOP ONLY
3'-11"6"
7' -3
1'-5"
3"
8"
10"
2"
1"
6"
4" C
LR
6 - #6 BARS CONTINUOUS
TOP & BOTTOM
7'-6"
2'1'0
DETAIL 1
CT4
4" THICK GRANULAR
SUBFOOTING
4" THICK GRANULAR
SUBFOOTING
4'-5" 2'-6" 7" 1" 1"
10"
8"
2"
7'-6"
3"Ø BLOCKOUT (TYP.) 81
2"Ø BLOCKOUT
2'-6"
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT4
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
PRECAST WINGWALL
EXPRESS™ FOOTING
3"Ø BLOCKOUT (TYP.)
PRECAST ARCH
EXPRESS™ FOOTING
6 - #6 x 7'-0" BENT BARS
PROVIDED BY CONTECH
3'- 0"
4'-0"
3'-0"
4'-0"
7' -6
10'-0"
NOTE:
#6 BARS MUST BE INSTALLED
THROUGH 3"Ø HOLES IN ARCH
EXPRESS™ FOOTINGS PRIOR TO
SETTING WINGWALL EXPRESS™
FOOTINGS
CT3
DETAIL
NOT TO SCALE
7' -6
PRECAST WINGWALL
EXPRESS™ FOOTING
3"Ø BLOCKOUT (TYP.)
PRECAST ARCH
EXPRESS™ FOOTING
NOTE:
#6 BARS MUST BE INSTALLED
THROUGH 3"Ø HOLES IN ARCH
EXPRESS™ FOOTINGS PRIOR TO
SETTING WINGWALL EXPRESS™
FOOTINGS
6 - #6 x 7'-0" BENT BARS
PROVIDED BY CONTECH
CT3
DETAIL
NOT TO SCALE
10'-0"
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT5
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
OVER GOOD SPRING CREEK
FRAILEY TOWNSHIP
AutoCAD SHX Text
FOOTING
AutoCAD SHX Text
FOOTING
AutoCAD SHX Text
FOOTING
AutoCAD SHX Text
FOOTING
SECTION D
CT30 1' 2' 4'
C
CT2
SECTION
2'1'0
2'-0"
2" x 51
2"
KEYWAY (TYP.)
C.I.P. CONCRETE
PRECAST
CONCRETE
1" G
R O
U T
7"
PRECAST
PEDESTAL
GROUT
6" 6"
PRECAST WINGWALL
9 - #6 BARS CONTINUOUS
TOP & BOTTOM
4" C
LR
2' -1
0" 2"
3' -0
7'
-6
6'-6" 6"
#5 x 9'-2" @ 6" IN BETWEEN
EACH CROSS MEMBER
TOP & BOTTOM
10'-0"
10"
PRECAST WINGWALL
10"
7" 2 '-0
VA
R
IE
S
FR
O
M
'-6 1 4"
T O
'-1
8"
1" G
R O
U T
4"Ø WEEPHOLE
CONCRETE MIX USED TO FILL EXPRESS™
FOOTING MUST BE ABLE TO BE WORKED
UNDER PEDESTAL SPACE, OR NON SHRINK
GROUT USED UNDER PEDESTAL PRIOR TO
CIP PORTION OF EXPRESS™ FOOTING
7'-0"1'-0" 1"1"1"
S H
IM
3" K
EY
W
AY
7' -6
3"Ø BLOCKOUT (TYP.) 81
2"Ø BLOCKOUT (TYP.)
3' -0
PRECAST CONCRETE
SIDE WALL
PRECAST CONCRETE
CROSS MEMBER
CONSTRUCTION
JOINT (TYP.) (OPTIONAL)
PRECAST
PEDESTAL
4" THICK GRANULAR
SUBFOOTING
10'-0"
2'-0"
4" THICK GRANULAR
SUBFOOTING
TYPICAL WINGWALL GROUT DETAIL
NOTES:
· MINIMUM 1" GROUT UNDER WINGWALL LEG &
ANCHOR STEM.
· AREA BETWEEN WINGWALL PEDESTAL AND
WINGWALL ANCHOR SHALL BE GROUTED
SOLID BEFORE BACKFILL.
· FORM BACKSIDE OF PEDESTAL TO
DIMENSIONS SHOWN ON FOUNDATION PLAN.
BACKSIDE OF
PEDESTAL
GROUTWINGWALL
PEDESTAL
1" G
R O
U T
M
IN
WINGWALL
WINGWALL ANCHOR
NOT TO SCALE
5'-01
2" MAX.
TYPE B OR C
WINGWALL ANCHOR
GROUT
SEE TYPICAL WINGWALL
GROUT DETAIL ON THIS SHEET
BACKFILL PER
CON/SPAN®
SPECIFICATIONS
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT6
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
5' -0
R
IS
E
5' -0
R
IS
E
3' -0
7'
-6
1" G
R O
U T
5' -6
1 4"
7' -0
8"
W
IN
G D
1' -6
8"
3"
3' -0
7'
-6
1" G
R O
U T
6' -6
1 4"
7' -1
8"
W
IN
G A
8"
3"
3' -0
7'
-6
1" G
R O
U T
6' -6
1 4"
7' -0
8"
W
IN
G C
8"
3"
3' -0
7'
-6
2' -6
1 4"
7' -1
8"
W
IN
G B
4' -7
8"
3"
5'-77 8"
(ALONG SKEW)
(TYP.)
2'-101 2"
(ALONG SKEW)
21'-8" HEADWALL
(22'-4" ALONG SKEW)
2'-6"
(ALONG SKEW)
5'-77 8"
(ALONG SKEW)
(TYP.)
2'-101 2"
(ALONG SKEW)
21'-8" HEADWALL
(22'-4" ALONG SKEW)
2'-6"
(ALONG SKEW)
(B20) 20'-0" SPAN
℄WINGWALL
CONNECTION PLATES
STREAMBED
ELEV. 889.48±
T/FOOTING
ELEV. 885.40
T/HEADWALL
ELEV. 900.29
T/HEADWALL
ELEV. 900.39
0 2' 4' 8'
UPSTREAM END ELEVATION
5' -0
T/PEDESTAL
ELEV. 892.90
(B20) 20'-0" SPAN
STREAMBED
ELEV. 888.50±
T/FOOTING
ELEV. 885.40
T/HEADWALL
ELEV. 900.29
T/HEADWALL
ELEV. 900.39
T/PEDESTAL
ELEV. 892.90
0 2' 4' 8'
DOWNSTREAM END ELEVATION
5' -0
℄WINGWALL
CONNECTION PLATES
5' -0
5' -0
2' -7
1 4" 2'
-7 1 4"
PA 3-RAIL BRIDGE BARRIER
(BY OTHERS)
PA 3-RAIL BRIDGE BARRIER
(BY OTHERS)
9"
9" 9"
9"
ROCK, CLASS R-8 CHOKED
W/ R-4 AND STREAMBED MATERIALS
(BY OTHERS)
ROCK, CLASS R-8 CHOKED
W/ R-4 AND STREAMBED MATERIALS
(BY OTHERS)
1" G
R O
U T
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT7
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
8" x 13
8" BUTYL ROPE
9" WIDE JOINT WRAP
PRIMER COMPATIBLE
WITH JOINT WRAP
TOP OF PRECAST
BRIDGE UNIT
NOT TO SCALE
PRECAST BRIDGE UNIT
TYPICAL JOINT SEAL DETAIL
SEE TYPICAL JOINT SEAL
DETAIL ON THIS SHEET
(TYP. BETWEEN UNITS)
BRIDGE LIMITS = 28'-6"
1'-6" HEADWALL FURNISHED
WITH END UNIT (TYP.) 1'-6"
PRECAST
WINGWALL
PRECAST
WINGWALL
JOINT SEAL BETWEEN END
UNIT AND HEADWALL (TYP.)
0 2' 4' 8'
E
CT2
SECTION
PA 3-RAIL BRIDGE BARRIER
(BY OTHERS)
STREAMBED
ELEV. 889.48±
STREAMBED
ELEV. 888.50±
ROCK, CLASS R-8 CHOKED
W/ R-4 AND STREAMBED MATERIALS
(BY OTHERS)
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT8
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
⅊WASHER 4" x 4" x 12"
GALV. (PW-1)
1" x 14" x 10" GALV. ⅊(P-2)
PRECAST
WINGWALL
℄8" TWO BOLT PRESET ANCHOR
FOR 1"Ø x 6" THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1"Ø x
4" BOLTS, (6" PITCH)]
⅊WASHER 4" x 4" x 12"
GALV. (PW-1)
1" x 14" x 10" GALV. ⅊(P-1)
2"
NOTE:
CONNECTION ⅊'S (P-1) MUST BE
POSITIONED WITH SMALL Ø HOLES
TOWARD PRECAST BRIDGE UNIT
2'1'0
@ HEADWALLDETAIL 4B
CT2
PRECAST
HEADWALL
℄8" TWO BOLT PRESET ANCHOR
FOR 1"Ø x 6" THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1"Ø x
4" BOLTS, (6" PITCH)]
10"
PRECAST
WINGWALL
℄8" TWO BOLT PRESET ANCHOR
FOR 1"Ø x 6" THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1"Ø x
4" BOLTS, (6" PITCH)]
41 2"
45°
1 4"±
JOINT
⅊WASHER 4" x 4" x 12"
GALV. (PW-1)
1" x 14" x 10" GALV. ⅊(P-1)
2"
NOTE:
CONNECTION ⅊'S (P-1) MUST BE
POSITIONED WITH SMALL Ø HOLES
TOWARD PRECAST BRIDGE UNIT
2'1'0
@ UNIT LEGDETAIL 4A
CT2
INSIDE FACE OF
PRECAST BRIDGE UNIT
℄6" TWO BOLT PRESET ANCHOR
FOR 1"Ø x 6" THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1"Ø x
4" BOLTS, (6" PITCH)]
10"
PRECAST
WINGWALL
℄8" TWO BOLT PRESET ANCHOR
FOR 1"Ø x 6" THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1"Ø x
4" BOLTS, (6" PITCH)]
41 2"
45°
1 4"±
JOINT
1'-6"
NOTE:
CONNECTION ⅊'S (P-2) MUST BE
POSITIONED WITH SMALL Ø HOLES
TOWARD PRECAST BRIDGE UNIT
INSIDE FACE OF
PRECAST BRIDGE UNIT
℄6" TWO BOLT PRESET ANCHOR
FOR 1"Ø x 6" THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1"Ø x
4" BOLTS, (6" PITCH)]
1 4"±
JOINT
2'1'0
@ UNIT LEGDETAIL 5A
CT2
2"
2"
⅊WASHER 4" x 4" x 12"
GALV. (PW-1)
1" x 14" x 10" GALV. ⅊(P-2)
PRECAST
WINGWALL
℄8" TWO BOLT PRESET ANCHOR
FOR 1"Ø x 6" THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1"Ø x
4" BOLTS, (6" PITCH)]
NOTE:
CONNECTION ⅊'S (P-2) MUST BE
POSITIONED WITH SMALL Ø HOLES
TOWARD PRECAST BRIDGE UNIT
PRECAST
HEADWALL
℄6" TWO BOLT PRESET ANCHOR
FOR 1"Ø x 6" THREADED ROD (2) WITH DOUBLE NUTS [ALT. 1"Ø x
4" BOLTS, (6" PITCH)]
1 4"±
JOINT
2'1'0
@ HEADWALLDETAIL 5B
CT2
2"
2"
1'-6"
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT9
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
POST-TENSIONING PER STANDARD DRAWING BC-798M
"MECHANICAL CONNECTION DETAILS PRECAST R.C. CULVERT"
MINIMUM TOTAL POST TENSION FORCE = 88.3 K (14.7 K PER STRAND)
MAXIMUM TOTAL POST TENSION FORCE = 88.3 K (14.7 K PER STRAND)
MAXIMUM DESIGN POST TENSION FORCE = 173.5 K (28.9 K PER STRAND)
TYPICAL POST-TENSIONING
JOINT DETAIL
NOT TO SCALE
TYPICAL POST-TENSIONING
STRAND ANCHOR DETAIL
NOT TO SCALE
2" x 2" x 1" PVC TEE
1" MIN.
4"
2" MIN.
3" x 4" x 3 4"
BEARING PLATE
REUSABLE PT
STRAND ANCHOR
4" x 5" x 63 4"
DEEP RECESS
2"Ø POST-TENSIONING
STRAND (CONTINUOUS)
1"Ø PVC
GROUT TUBE
1'-0"±
2" SCH 40 PVC DUCT FOR
POST-TENSIONING STRAND
2"± JOINT
CLOSED CELL TYPE 2C2
NEOPRENE AT INSIDE FACE
& OUTSIDE FACE
TYPE 2C2 NEOPRENE
SPONGE DONUT 1
2"Ø POST-TENSIONING
STRAND (CONTINUOUS)
2" SCH 40 PVC DUCT FOR
POST-TENSIONING STRAND
2"± JOINT
CLOSED CELL TYPE 2C2
NEOPRENE AT INSIDE FACE
& OUTSIDE FACE
TYPE 2C2 NEOPRENE
SPONGE DONUT
STRESSING SEQUENCE
1.BOTTOM OF LONG LEG - 25%
2.BOTTOM OF SHORT LEG - 25%
3.TOP OF LONG LEG - 25%
4.TOP OF SHORT LEG - 25%
5.TOP STRANDS - 25%
REPEAT SEQUENCE IN 25% INCREMENTS TO 100%
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT10
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
1. DESCRIPTION
THIS WORK IS THE FURNISHING AND CONSTRUCTING OF
CON/SPAN BRIDGE SYSTEM (PRECAST ARCH UNITS,
HEADWALLS & WINGWALLS) INCLUDING EXCAVATION OF
ON-SITE SOILS AND PLACEMENT AND COMPACTION OF
STRUCTURAL AND RANDOM BACKFILL, IN CONFORMITY
WITH THE LINES, GRADES, DIMENSIONS, LOCATIONS, AND
SECTIONS SHOWN ON THE APPROVED DRAWINGS AND IN
ACCORDANCE WITH THE CONTRACT DOCUMENTS AND
THE REQUIREMENTS SET FORTH HEREIN.
2. MATERIALS
A. PROVIDE MATERIALS AND WORKMANSHIP IN
ACCORDANCE WITH PUBLICATION 408, AND
SUPPLEMENTS THERETO, AND/OR SPECIAL
CONDITIONS AS SPECIFIED HEREIN.
B. PRECAST CONCRETE PRODUCTS. SECTION 714 AND
AS FOLLOWS:
1. CONCRETE COMPONENTS: PROVIDE CONCRETE IN
ACCORDANCE WITH SECTION 704 WITH A MINIMUM
28 DAY COMPRESSIVE STRENGTH OF 5000 PSI. DO
NOT PLACE CONCRETE WHEN AMBIENT
TEMPERATURES ARE BELOW 40°F OR ABOVE
100°F.
2. CEMENT CONCRETE: SECTION 704. USE CLASS A
CONCRETE FOR FOOTINGS AND CLASS AA FOR
CURBS AND PARAPETS. DO NOT USE ADMIXTURE
CONTAINING CHLORIDES.
C. REINFORCING STEEL: SECTION 709.1(A)1.
D. DEFORMED WELDED WIRE FABRIC: SECTION 709.4.
SMOOTH WELDED WIRE FABRIC: SECTION 709.3.
E. SELECTED BORROW EXCAVATION - STRUCTURAL
BACKFILL: PUB. 408 AS SHOWN ON STANDARD
DRAWING RC-12. DO NOT USE METALLURGICAL SLAG
OR CINDERS OR ANY 'R' CLASS ROCK.
F. GEOTEXTILES: CLASS 4, TYPE A, SECTION 735.
G. JOINT WRAP: ASTM C-877 TYPE I OR C-877 TYPE II,
TYPE III (EXCLUDING STEEL STRAPS) WITH PRIMER.
H. MORTAR: SECTION 705.7(A).
I. GROUT: SHALL CONTAIN PORTLAND CEMENT, SAND
AND WATER AND SHALL HAVE A MINIMUM
COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS.
J. CONCRETE SEALERS: APPROVED BY MTD.
K. PIPE UNDERDRAIN: SECTION 610.2.
L. CERTIFICATION: SECTION 106.03(B)3.
3. FABRICATION, TESTING AND INSPECTION.
A. FABRICATE IN ACCORDANCE WITH APPROVED SHOP
DRAWINGS AND APPROVED QUALITY CONTROL PLAN,
AND PUB. 408 SECTION 714. MAINTAIN SECONDARY
CONCRETE CURE IN A MINIMUM 50°F ENVIRONMENT
UNTIL THE UNITS HAVE REACHED A COMPRESSIVE
STRENGTH OF 3500 PSI.
B. CONCRETE FINISH. PROVIDE STEEL FORM FINISH FOR
THE FRONT FACE. THE REAR FACE SHALL HAVE A
FLOATED SURFACE FINISH UNLESS OTHERWISE
INDICATED OR SPECIFIED. SCREED TO ELIMINATE
OPEN POCKETS OF AGGREGATE AND SURFACE
DISTORTIONS IN EXCESS OF 1/4" ON BOTH FACES OF
THE PRECAST ARCH UNITS CONCRETE
COMPONENTS.
WHEN A SPECIAL OR DECORATIVE SURFACE FINISH IS
REQUIRED, DISPLAY THE TYPICAL SAMPLE OF THE
FACE SEGMENT SHOWING THE COLOR, TEXTURE AND
FINISH FOR APPROVAL.
C. TOLERANCES: MANUFACTURE ALL PRECAST
CONCRETE COMPONENTS WITHIN THE FOLLOWING
TOLERANCES:
3. THE INTERNAL DIMENSION DOES NOT VARY MORE
THAN 1% NOR MORE THAN 1" FROM THE DESIGN
DIMENSIONS WHICHEVER IS LESS.
4. THE SLAB AND WALL THICKNESS DO NOT VARY 1/4"
LESS THAN THAT SHOWN IN THE DESIGN. A
THICKNESS MORE THAN REQUIRED IN THE DESIGN
WILL NOT CAUSE REJECTION.
5. THE MAXIMUM VARIATION IN POSITION OF THE
REINFORCEMENT IN ANY DIRECTION WILL BE ± 1/2"
. IN NO CASE MAY THE COVER OVER THE
REINFORCEMENT VARY BY MORE THAN 1/4" FROM
THE POSITION SHOWN ON THE APPROVED
DRAWINGS. THE COVER AT THE END OF THE
REINFORCEMENT WILL BE A MINIMUM OF 1/2" AT
THE MATING SURFACES.
6. THE UNDERRUN IN LENGTH OF A SECTION WILL
NOT BE MORE THAN 1/2" IN ANY PRECAST ARCH
UNIT.
7. THE OUTSIDE DIAGONAL DIMENSIONS SHALL NOT
VARY MORE THAN 1% NOR MORE THAN 1" FROM
THE DESIGN DIMENSIONS WHICHEVER IS LESS.
8. OTHER TOLERANCES AS INDICATED.
D. REJECT INDIVIDUAL PRECAST CONCRETE
COMPONENTS FOR ANY OF THE FOLLOWING:
1. FRACTURES OR CRACKS PASSING THROUGH THE
WALL, EXCEPT FOR A SINGLE END CRACK THAT
DOES NOT EXCEED ONE HALF THE THICKNESS OF
THE WALL.
2. DEFECTS THAT INDICATE PROPORTIONING, MIXING
AND MOLDING NOT IN COMPLIANCE WITH THE
SPECIFICATION AS SPECIFIED OR INDICATED.
3. HONEYCOMBED OR OPEN TEXTURE.
4. TEST CORE STRENGTH IS LESS THAN DESIGN
CONCRETE STRENGTH.
5. DAMAGED ENDS WHERE SUCH DAMAGE WOULD
PREVENT MAKING A SATISFACTORY JOINT.
6. DIMENSIONS NOT CONFORMING TO THE
ALLOWABLE TOLERANCES AS SPECIFIED.
7. COLOR VARIATION ON FRONT FACE.
MARK THE REJECTED PRECAST CONCRETE
COMPONENTS "REJECTED FOR PENNDOT USE" WITH
WATERPROOF PAINT.
E. REPAIR AND REPAIR PROCEDURES REQUIRE
APPROVAL BY THE ENGINEER.
F. MARK EACH PRECAST ARCH UNIT WITH
WATERPROOF PAINT TO SHOW THE FOLLOWING
INFORMATION ON THE SURFACE OF THE VERTICAL
LEG OF THE UNIT;
· SIZE: SPAN x RISE (IN FEET)
· EARTH COVER (IN FEET)
· DATE OF MANUFACTURE
· NAME OR TRADEMARK OF THE MANUFACTURER
4. CONSTRUCTION
A. IN ACCORDANCE WITH THE APPLICABLE SECTIONS
OF THE SPECIFICATIONS, PUBLICATION 408,
SUPPLEMENTS THERETO, AND/OR THE SPECIAL
PROVISIONS FOR EACH RESPECTIVE ITEM, AND THE
ADDITIONAL REQUIREMENTS SPECIFIED HEREIN.
SUBMIT CONSTRUCTION PROCEDURES AND
PERMISSIBLE VARIATIONS OTHER THAN THOSE
CONTAINED HEREIN, FOR APPROVAL.
NO CONSTRUCTION OF THE PRECAST CONCRETE
BRIDGE WILL BE PERMITTED WITHOUT THE
APPROVED SHOP DRAWINGS.
B. EXCAVATION AND FOUNDATIONS. GRADE THE
FOUNDATION FOR THE STRUCTURE LEVEL FOR A
WIDTH OF 1'-0" BEYOND THE WIDTH OF THE STRIP
FOUNDATION WHEN STRIP FOUNDATIONS ARE
UTILIZED. PRIOR TO CONSTRUCTION, EXCEPT WHERE
CONSTRUCTED IN ROCK, COMPACT THE FOUNDATION
WITH A SMOOTH WHEEL VIBRATORY ROLLER.
REMOVE ALL FOUNDATION SOILS DETERMINED BY
THE ENGINEER TO BE UNSUITABLE, AND REPLACE
WITH GRANULAR MATERIAL (2A). EXCAVATE IN
ACCORDANCE WITH SECTION 203 TO THE LIMITS AND
CONSTRUCTION STAGES AS INDICATED.
PROVIDE PROPERLY CURED (REACH A MINIMUM
COMPRESSIVE STRENGTH OF 2750 PSI BEFORE
PLACEMENT OF THE PRECAST CONCRETE
COMPONENTS) CAST-IN-PLACE FOOTINGS, IN
ACCORDANCE WITH GRADE SHOWN. PROVIDE A
SMOOTH FLOAT FINISH TO THE DIMENSIONS AND
DETAILS AS INDICATED. IN THE PRECAST ARCH UNIT
FOOTINGS, FORM A 3" DEEP KEYWAY IN THE TOP
SURFACE, 3" CLEAR OF THE INSIDE AND OUTSIDE
FACES OF THE BRIDGE PRIOR TO PLACEMENT OF THE
PRECAST CONCRETE SEGMENT, OR AS INDICATED
ON THE DESIGN DRAWINGS. NO KEYWAY IS
REQUIRED IN THE PRECAST WINGWALL FOOTING.
C. ERECTION OF PRECAST ARCH UNITS: INSTALL
PRECAST ARCH UNITS IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS AS SHOWN
ON THE APPROVED SHOP DRAWINGS.
SHIPPING AND PLACEMENT CABLES ARE PROVIDED IN
PRECAST ARCH UNITS WITH SPANS GREATER THAN
24'-0", TO PREVENT THE LEGS FROM SPREADING
DURING HANDLING AND TRANSPORTATION. THESE
HANDLING CABLES SHOULD NOT BE REMOVED UNTIL
AFTER THE PRECAST ARCH UNIT IS PLACED AND
GROUTED. IF THESE CABLES MUST BE REMOVED
PRIOR TO PLACEMENT. CON/SPAN MANUFACTURER
MUST BE CONSULTED FOR ALTERNATE
RECOMMENDED PROCEDURE.
TAKE SPECIAL CARE IN SETTING THE PRECAST ARCH
UNITS TO THE TRUE LINE AND GRADE. PLACE
PRECAST ARCH UNITS ON 5" x 5" HARDBOARD SHIMS.
PROVIDE A MINIMUM OF A 1/2" GAP AND A MAXIMUM
OF 2" BETWEEN THE FOOTING AND THE BOTTOM OF
THE PRECAST ARCH UNITS VERTICAL LEGS. FILL GAP
WITH APPROVED CEMENT GROUT OR CEMENT
MORTAR.
DO NOT EXCEED 3/4" JOINT WIDTH BETWEEN
ADJACENT PRECAST ARCH UNITS.
CLEAN DIRT AND DELETERIOUS SUBSTANCES FROM
THE SURFACES AND JOINTS. IN THE RECESS FORMED
BY THE CHAMFER ON THE EDGES OF THE PRECAST
ARCH UNITS, PLACE A 7/8" x 1 3/8" STRIP OF BUTYL
ROPE ALONG THE ENTIRE LENGTH OF THE JOINT
EXTERIOR. COVER THE ARCH-UNIT JOINT EXTERIOR
WITH A MINIMUM OF A 9" WIDE JOINT WRAP. COVER
THE JOINT CONTINUOUSLY TO THE BOTTOM OF THE
LEGS. WHERE REQUIRED, LAPS IN THE JOINT WRAP
SHALL RUN DOWNHILL. EXERCISE EXTRA CARE
DURING BACKFILLING TO KEEP THE JOINT WRAP IN
ITS PROPER LOCATION OVER THE JOINT.
COVER THE REAR FACE OF THE JOINT BETWEEN THE
PRECAST ARCH UNITS AND PRECAST WINGWALLS
WITH A MINIMUM 2'-0" WIDE STRIP OF FILTER FABRIC.
WHEN NOT POST TENSIONED INSTALL ANGLES,
MECHANICALLY SECURING PRECAST ARCH UNITS TO
CAST-IN-PLACE FOOTINGS. BOLT ANGLE TO PRECAST
ARCH UNIT AND USE BASE OF ANGLE AS A TEMPLATE
FOR DRILLING ANCHOR HOLES INTO FOUNDATION.
USE ADHESIVE ANCHORS FOR SECURING ANGLES TO
FOUNDATION.
WHEN APPLICABLE, CONTRACTOR SHALL PROVIDE
AND APPLY APPROVED CONCRETE MEMBRANE
SEALER, AS RECOMMENDED BY THE SEALER
MANUFACTURER, ON THE TOP OF THE PRECAST
ARCH UNIT AND THE PRECAST ARCH UNIT JOINT
MATING SURFACES, FOR THE FULL LENGTH OF THE
STRUCTURE OR THE LIMITS WHICH ARE IN CONTACT
WITH THE BACKFILL.
D. BACKFILLING AND COMPACTION: DO NOT PLACE
BACKFILL AGAINST ANY INSTALLED STRUCTURAL
COMPONENTS UNTIL THEY HAVE BEEN APPROVED BY
THE ENGINEER.
PLACE SELECTED BORROW EXCAVATION,
STRUCTURE BACKFILL (2A, #57 STONE OR APPROVED
ALTERNATE) WITHIN 4'-0" OF EACH SIDE OF THE
PRECAST ARCH UNITS AND AS INDICATED IN THE
BACKFILL DIAGRAMS (ADJACENT) FOR THE PRECAST
ARCH UNITS AND WINGWALLS, AND IN ACCORDANCE
WITH THE REQUIREMENT OF SECTION 206.3(B) AND
STANDARD RC-12. DO NOT USE ANY 'R' CLASS ROCK
FOR STRUCTURE BACKFILL. THE DIFFERENCE IN
HEIGHT OF THE COMPACTED BACKFILL ON EACH SIDE
OF THE ARCH MUST NOT EXCEED 2'-0". FOR FILL
HEIGHTS LESS THAN OR EQUAL TO 2'-0", THE
FINISHED GRADE, MINUS THE PAVEMENT THICKNESS,
SHALL BE THE BOUNDARY LINE FOR THE C.B.Z. FOR
FILL HEIGHTS GREATER THAN 2'-0", CBZ LIMITS SHALL
BE 2'-0" ABOVE THE ARCH CROWN.
PLACE AND COMPACT STRUCTURAL AND RANDOM
BACKFILL IN ACCORDANCE WITH RC-12 AND SECTION
206.3(B).
ACHIEVE THE BACKFILL COMPACTION WITHIN THE
4'-0" ON EACH SIDE OF PRECAST ARCH UNIT AND
OVER THE TOP OF THE PRECAST ARCH UNIT UNTIL IT
IS COVERED TO A MINIMUM DEPTH OF 6", AND WITHIN
1'-0" FROM THE BACK OF THE PRECAST WINGWALL
ANCHORS, BY USING AT LEAST THREE PASSES WITH
LIGHT MECHANICAL TAMPERS, ROLLERS OR
VIBRATORY SYSTEM. ACCOMPLISH BACKFILL
COMPACTION WITHOUT DISTURBANCE OR
DISTORTION OF THE PRECAST CONCRETE
COMPONENTS.
E. DRAINAGE. INSTALL PIPE UNDERDRAIN AS INDICATED.
SEPARATE ALL INTERFACING MATERIALS OF
DISTINCTLY DIFFERENT GRADATION BY USING
GEOTEXTILE FILTER FABRIC. (CLASS 2, TYPE A),
SUPPLIED BY CONTRACTOR.
F. DEWATERING. FURNISH, INSTALL, OPERATE AND
MAINTAIN SATISFACTORY DEWATERING SYSTEMS AS
REQUIRED TO MAINTAIN THE SITE IN A DRY AND
WORKABLE CONDITION. INCLUDE ALL EQUIPMENT
AND MATERIALS, AND CONTINUE AS LONG AS
NECESSARY.
G. TECHNICAL ASSISTANCE. HAVE A COMPANY
REPRESENTATIVE PRESENT AT THE PROJECT SITE
TO ASSIST THE FABRICATOR, CONTRACTOR AND
ENGINEER. PROVIDE A TECHNICAL REPRESENTATIVE
TO ASSIST IN THE EVENT UNUSUAL PROBLEMS OR
SPECIAL CIRCUMSTANCE.
CONSTRUCTION SPECIFICATIONS FOR CON/SPAN PRECAST CONCRETE STRUCTURE
LIMITS OF
EXCAVATION
IN-SITU
SOIL
IN-SITU
SOIL
IN-SITU
SOIL
FI
LL
H
EI
G H
T
FINISHED
GRADE
4'-0"
MIN.
A A B B
LIMITS OF CRITICAL
BACKFILL ZONE B
BACKFILL REQUIREMENTS
CC
TO ROADWAY
BASE/ FINISH
GRADE OR 2'-0" MIN.
ARCH UNIT PEDESTAL
FOUNDATION (TYP.)
1'-0"
LIMITS OF CRITICAL
BACKFILL ZONE (CBZ)
1'-0"
MIN.
FINISHED GRADE
COMPACTED COHESIONLESS MATERIAL
(#57 STONE OR APPROVED ALTERNATE)
PER DM-4 SECTION 11.4
PRECAST
WINGWALL
GROUT
WALL BACKFILL REQUIREMENTS
1' -0
(M
AX
1'-0"
PRECAST WINGWALL
PEDESTAL FOUNDATION
CHECKED:
DRAWN:
EA
DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\6
0\
\6
7-
-C O
N _S
PA
N
\D R
AW
IN
G S\
C O
N
TR
AC
T\
PR
E-
-0
-C
B- C
O N
-B .D
W G
2/
/2
3:
P M
SHEET NO.:
OF CT11
PAC
12/11/2023 DATE:PROJECT No.:
656187 SEQ. No.:
010/030
CT11
CONTRACT
DRAWING800-338-1122 513-645-7000 513-645-7993 FAX
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
www.ContechES.com
BRIDGE SYSTEMS
SCHUYLKILL COUNTY, PENNSYLVANIA
CLARK STREET (T-436) BRIDGE REPLACEMENT
| Sheets and Views |
| PRE-656187-010-CB-CON-B-CT1 |
| PRE-656187-010-CB-CON-B-CT2 |
| PRE-656187-010-CB-CON-B-CT3 |
| PRE-656187-010-CB-CON-B-CT4 |
| PRE-656187-010-CB-CON-B-CT5 |
| PRE-656187-010-CB-CON-B-CT6 |
| PRE-656187-010-CB-CON-B-CT7 |
| PRE-656187-010-CB-CON-B-CT8 |
| PRE-656187-010-CB-CON-B-CT9 |
| PRE-656187-010-CB-CON-B-CT10 |
| PRE-656187-010-CB-CON-B-CT11 |
File details come from the government source that posted it. Updated .