2-3-CR2700-27284500 Hazmat Survey.pdf
PDF 4 MB Posted
- Solicitation number
- CR27000
- Issued by
- Utah
About this file
This is a Limited Asbestos Inspection and Lead-Based Paint Survey prepared by Hill West Environmental for the State of Utah Department of Natural Resources (DNR) Richfield Regional Complex office remodel project. The survey was conducted on April 9, 2026, at the facility located at 2031 Industrial Park Road, Richfield, Utah 84701, and was requested by Ms. Aubrey Stapel, Project Manager with the State of Utah Division of Facilities Construction and Management (DFCM). The inspection focused exclusively on areas impacted by the planned office remodel, which includes converting existing space to accommodate two to three offices. The survey specifically examined suspect materials including sheetrock wall systems, ceiling texturing, and baseboards to identify any asbestos-containing materials (ACM) or lead-based paint components that would require remediation prior to renovation activities.
The inspection results indicate that no asbestos-containing materials were detected in any of the samples collected from the renovation areas, and no lead was detected in building components within the project area using XRF (X-ray Fluorescence) analysis with a detection threshold of 0.4 mg/cm². No universal, hazardous, or toxic wastes were identified that would be impacted during the renovation project. The report includes provisions requiring that if contractors discover additional suspect materials during renovation or demolition work that were not sampled during this inspection, they must cease operations and notify DFCM for additional sampling. The construction cost estimate for the office remodel project is $94,000.00, with the work restricted to invited contractors including PRT Builders, Rod Lewis Construction, and Tushar Contracting.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 1-1-CR27000-27284500 Solicitation.pdf | ||
| 3-2-CR27000-27284500 Approved Plans.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIMITED ASBESTOS INSPECTION
AND LEAD-BASED PAINT SURVEY
Department of Natural Resources - Richfield Regional Complex
2031 Industrial Park Road
Richfield, Utah 84701
Office Remodel
April 23, 2026
Prepared for:
Ms. Aubrey Stapel
Project Manager, Statewide Programs
State of Utah
Department of Administrative Services
Division of Facilities Construction and Management (DFCM)
Taylorsville State Office Building
4315 South 2700 West, 3rd Floor
Taylorsville, Utah 84129-2128
Prepared by:
Hill West Environmental
7963 Douglas Drive
Park City, Utah 84098
State of Utah Company Certification # ASBC-495
Claude Dahlk, CHMM, CIEC
(801) 450-8060
EXECUTIVE SUMMARY
On April 9, 2026, Hill West Environmental conducted a limited pre-renovation inspection for asbestos and lead-based paint at Department of Natural Resources (DNR) - Richfield Regional Complex located at 2031 Industrial Park Road, Richfield, Utah 84701. The project includes the office remodel of the DNR
- Richfield regional complex.
Ms. Aubrey Stapel, Project Manager with the State of Utah, Division of Facilities Construction and Management (DFCM) requested this inspection to identify asbestos-containing materials (ACM) and building components with lead-based paint that need to be addressed before the building is renovated.
Suspect materials that will be impacted included sheetrock wall systems, ceiling texturing, and baseboard. Areas in which renovations are to occur were inspected, and all other areas were not inspected as part of this survey. Hill West identified the following asbestos-containing materials (ACM) and lead-based paint during this inspection:
Asbestos-Containing Materials
Homogeneous Area Number
Material Description
Asbestos Content
Amount
Cost Estimate
N/A No asbestos materials were identified in the samples collected during this inspection.
N/A N/A N/A
Building Components with XRF Lead readings ≥ 0.4 mg/cm2
Material Type Reading (mg/cm2)
Lead was not detected within the project area. N/A
Universal, Hazardous, and Toxic Wastes
Material Type Quantity
No Universal, Hazardous, and Toxic Wastes will be impacted during this renovation project. N/A
Conclusions
ACM – Asbestos Containing Materials (ACM) were not detected within any of the suspect building materials that were tested within the project area.
If the renovation or demolition contractor discovers additional suspect building materials that were not sampled as part of this inspection, they shall stop working and notify DFCM so that the materials can be sampled.
Lead – Lead was not detected within any building components within the upgrade area. If the renovation or demolition contractor discovers additional suspect building materials that were not sampled as part of this inspection that will be impacted, they shall stop working and notify DFCM so that the materials can be sampled.
Universal, Hazardous and Toxic Wastes – No Universal, Hazardous, and Toxic Wastes will be impacted during this renovation project.
1.0 INTRODUCTION
As per DFCM’s instructions, Hill West Environmental conducted a limited asbestos inspection of the Department of natural resources - Richfield regional complex located at 2031 Industrial Park Road, Richfield, Utah 84701. Due to the remodel and upgrade projects, Hill West was instructed to only inspect areas that will be impacted during the renovation project.
The purpose of this survey was to identify the existence, extent, and condition of both friable and non-friable asbestos-containing materials (ACM) and lead-based paint within the renovation areas.
2.0 SITE VISIT /OBSERVATIONS
2.1 Asbestos Inspection
On April 9, 2026, Hill West Environmental visited the site to survey the renovation areas of the building. A complete asbestos inspection of the areas that will be impacted during renovations was made to determine conditions and develop a sampling scheme for the areas. Table 1 summarizes the asbestos inspection results.
Table 1 – Asbestos Materials
Homogenous Area Number
Material Description/Location Asbestos Content
Amount Cost Estimate
N/A No asbestos materials were identified in the samples collected during this inspection.
N/A N/A N/A
Appendix A contains photographs of samples.
Appendix B contains analytical results and certifications.
2.2 Lead-based Paint Inspection
On April 9, 2026, Hill West Environmental conducted a limited lead-based paint inspection of the DNR - Richfield Regional Complex within the project work area.
Direct measurement of lead in paint/dust were made using a Niton XL2 X-ray Fluorescence (XRF) Spectrum Analyzer. The Niton XRF non-destructively measures lead concentrations of painted surfaces, regardless of the number of layers present.
According to the manufacturer, the detection limit (lower limit of reliable measurement) for this instrument is 0.1 milligrams per square centimeter (mg/cm2) ±0.3 mg/cm2 with the instrument set on the “quick” measuring mode.
The quick mode provides 95% confidence that the lead concentration in the paint is above or below the set point of the instrument which, for this survey is 0.4 mg/cm2. For this survey, measurements below 0.4 mg/cm2 were not reported as lead containing.
The Niton XRF sometimes reports negative values. According to the manufacturer, negative values should be expected and interpreted as zero lead content due to the statistical variability of XRF measurement technology. Both HUD and the EPA recognize the statistical variability of XRF technology and the possibility of obtaining negative values where the lead content is near zero.
Table 2 summarizes the lead-based paint inspection results. Measurements are reported in milligrams of lead per square centimeter (mg/cm2). All the coatings tested during this inspection were in good to fair condition. Only positive readings (>0.4 mg/cm2) are summarized in Table 2. Appendix B contains all XRF readings for this survey.
Table 2 – Positive Lead-Based Paint/Lead Dust Readings
Building Component Material Description/Location Lead Content (mg/cm2)
N/A No lead was detected within the upgrade area. N/A
3.0 RESULTS
Table 3 summarizes the analytical results for the asbestos samples collected.
Table 3 – Asbestos Analytical Results
Sample Number
Homogeneous Area Number
Material Sampled Sample Location Estimated Quantity*
Analytical Results
DR – 01A M001 Sheetrock Wall System Office <400 ft2 None Detected
DR – 01B M001 Sheetrock Wall System Office <400 ft2 None Detected
DR – 01C M001 Sheetrock Wall System Office <400 ft2 None Detected
DR – 02A S001
Textured Ceiling
Material Office <200 ft2 None Detected
DR – 02B S001
Textured Ceiling
Material Office <200 ft2 None Detected
DR – 02C S001
Textured Ceiling
Material Office <200 ft2 None Detected
DR – 03A M002 Gray Vinyl Baseboard Office <250 linear feet None Detected
DR – 03B M002 Gray Vinyl Baseboard Office <250 linear feet None Detected
DR – 03C M002 Gray Vinyl Baseboard Office <250 linear feet None Detected
* Estimated Quantity is based on amount to be disturbed during the upgrade project.
4.0 DISCUSSION/CONCLUSTIONS
In Utah, EPA asbestos regulations are administered by the Utah Division of Air Quality. Utah Occupational Safety and Health Administration (UOSHA) has adopted the Federal OSHA regulations. In addition, the Salt Lake Valley Health Department (SLVHD) regulates demolition activities in Salt Lake County. The SLVHD regulations for pre-demolition building inspections require an asbestos inspection, but also require building owners to inspect the building for other hazardous materials such as universal wastes, hazardous and toxic wastes and lead-based paint. Similar to asbestos, these wastes, if present must be removed prior to demolition/renovation.
A copy of this report should be on-site during all renovation activities.
This limited asbestos and lead-based paint inspection was conducted at the Department of Natural Resources - Richfield regional complex that will be impacted during renovation activities. Only items that are believed to be impacted during renovation activities were inspected during this survey. This survey is not intended to represent an exhaustive research into all asbestos or other hazards or conditions which may exist within other buildings located at this project site.
This report does not purport to represent future indoor conditions or events.
Situations or activities which transpire subsequent to this report, which result in adverse environmental, construction and/or engineering impacts, are not to be construed as relevant to this study.
This report is intended for the sole use of Hill West's client. This report may not be used or relied upon by any other party without the written consent of Hill West.
The scope of services performed in execution of the evaluation may not be appropriate to satisfy the needs of other users, and the use or re-use of this document or the findings, conclusions, or recommendations is at risk of said user. Appendix B contains all Company certifications and individual inspector certifications.
Prepared by:
Claude Dahlk, CHMM, CIEC Asbestos Inspector ASB-0433
Appendix A
Photographs of Samples
Richfield DNR Regional Complex
2031 Industrial Park Road
Richfield, Utah
DR – 01A Sheetrock Wall System
DR– 01B Sheetrock Wall System
DR – 01C Sheetrock Wall System
DR – 02A Textured Ceiling Material
DR – 02B Textured Ceiling Material
DR – 02C Textured Ceiling Material
DR – 03A Gray Baseboard
DR – 03B Gray Baseboard
DR – 03C Gray Baseboard
End of Photographs.
Appendix B
Analytical Results and Certifications
Approved by:
Approved Signatory Renee Luna-Trepczynski
Report for:
Claude Dahlk Hill West Environmental, LLC 7963 Douglas Drive Park City, UT 84098
Regarding:
Eurofins Aerotech Built Environment Testing, LLC Project: DNR Richrield; 2031 Industrial Park Road, Richfield, UT
EML ID: 4494982
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
Eurofins Aerotech Built Environment Testing, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM: 04-16-2026
Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA 600/R-93-116, EBET-PLM-SOP83921) NVLAP Lab Code 500031-0
EMLab ID: 4494982, Page 1 of 5Eurofins Aerotech Built Environment Testing, LLC
Eurofins Aerotech Built Environment Testing, LLC 1501 West Knudsen Drive, Phoenix, AZ 85027
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: DNR Richrield; 2031 Industrial Park Road, Richfield, UT
Date of Sampling: 04-09-2026 Date of Receipt: 04-15-2026 Date of Report: 04-16-2026
ASBESTOS PLM REPORT
Total Samples Submitted: 9 Total Samples Analyzed: 9
Total Samples with Layer Asbestos Content > 1%: 0
Location: DR-01A, Sheetrock wall system Lab ID-Version‡: 22599190-1
Sample Layers Asbestos Content White Compound with Paint ND
Cream Tape ND White Joint Compound ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
Location: DR-01B, Sheetrock wall system Lab ID-Version‡: 22599191-1
Sample Layers Asbestos Content White Compound with Paint ND
Cream Tape ND White Joint Compound ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
Location: DR-01C, Sheetrock wall system Lab ID-Version‡: 22599192-1
Sample Layers Asbestos Content White Compound with Paint ND
White Compound with Paint 2 ND Cream Tape ND
White Joint Compound ND White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
EMLab ID: 4494982, Page 2 of 5Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: DNR Richrield; 2031 Industrial Park Road, Richfield, UT
Date of Sampling: 04-09-2026 Date of Receipt: 04-15-2026 Date of Report: 04-16-2026
ASBESTOS PLM REPORT
Location: DR-02A, Textured ceiling material Lab ID-Version‡: 22599193-1
Sample Layers Asbestos Content White Texture with Paint ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate
Location: DR-02B, Textured ceiling material Lab ID-Version‡: 22599194-1
Sample Layers Asbestos Content White Texture with Paint ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate
Location: DR-02C, Textured ceiling material Lab ID-Version‡: 22599195-1
Sample Layers Asbestos Content White Texture with Paint ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate
Location: DR-03A, Gray base board Lab ID-Version‡: 22599196-1
Sample Layers Asbestos Content Gray Cove Base ND Cream Mastic ND
Sample Composite Homogeneity: Moderate
EMLab ID: 4494982, Page 3 of 5Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: DNR Richrield; 2031 Industrial Park Road, Richfield, UT
Date of Sampling: 04-09-2026 Date of Receipt: 04-15-2026 Date of Report: 04-16-2026
ASBESTOS PLM REPORT
Location: DR-03B, Gray base board Lab ID-Version‡: 22599197-1
Sample Layers Asbestos Content Gray Cove Base ND Cream Mastic ND
Sample Composite Homogeneity: Moderate
Location: DR-03C, Gray base board Lab ID-Version‡: 22599198-1
Sample Layers Asbestos Content Gray Cove Base ND Cream Mastic ND
Sample Composite Homogeneity: Moderate
EMLab ID: 4494982, Page 4 of 5Eurofins Aerotech Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: DNR Richrield; 2031 Industrial Park Road, Richfield, UT
Date of Sampling: 04-09-2026 Date of Receipt: 04-15-2026 Date of Report: 04-16-2026
ASBESTOS PLM REPORT
PROJECT ANALYST AND SIGNATORY REPORT
Project Analyst
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
Analyst: Renee Luna-Trepczynski
EMLab ID: 4494982, Page 5 of 5Eurofins Aerotech Built Environment Testing, LLC
Inspector: Dominic Hobbs
Date Inspected: 4-9-26
PB-2781
Limited-Lead Based Paint Readings DNR Regional Complex
Richfield, Utah
Index Time Results Component Substrate Condition Color Floor PbC
53 4/9/2026 15:34 Positive CALABRATE 0.87
54 4/9/2026 15:34 Positive CALABRATE 1.2
55 4/9/2026 15:34 Positive CALABRATE 1.01
56 4/9/2026 15:35 Negative CEILING DRYWALL FAIR WHITE <LOD
57 4/9/2026 15:35 Negative CEILING DRYWALL FAIR WHITE <LOD
58 4/9/2026 15:35 Negative CEILING DRYWALL FAIR WHITE <LOD
59 4/9/2026 15:35 Negative CEILING DRYWALL FAIR WHITE <LOD
60 4/9/2026 15:35 Negative WALL DRYWALL FAIR GREEN <LOD
61 4/9/2026 15:35 Negative WALL DRYWALL FAIR GREEN <LOD
62 4/9/2026 15:36 Negative WALL DRYWALL FAIR GREEN <LOD
63 4/9/2026 15:36 Negative WALL DRYWALL FAIR GREEN 0.03
64 4/9/2026 15:36 Negative TRIM METAL FAIR GRAY <LOD
65 4/9/2026 15:36 Negative TRIM METAL FAIR GRAY <LOD
66 4/9/2026 15:36 Negative TRIM METAL FAIR GRAY <LOD
67 4/9/2026 15:36 Negative TRIM METAL FAIR GRAY <LOD
68 4/9/2026 15:36 Negative DOOR WOOD FAIR STAIN <LOD
69 4/9/2026 15:37 Negative DOOR WOOD FAIR STAIN 0.16
70 4/9/2026 15:37 Negative DOOR WOOD FAIR STAIN 0.03
71 4/9/2026 15:37 Positive CALABRATE 1.24
72 4/9/2026 15:37 Positive CALABRATE 1.08
73 4/9/2026 15:37 Positive CALABRATE 1.07
| DFCM Limited Haz Mat Report DNR Richfield Office Remodel 04 24 2026 |
| ACM Photo Log DNRR Richfield 04 23 26 |
| DFCM Limited Haz Mat Report DNR Richfield Office Remodel 04 24 2026 |
| Project-4494982_DNR Richrield |
| Copy of Copy of DNR Richfield Lead 04 26 26 |
| 2026 Dahlk Hobbs HW ACM Lead Certs |
| scan_20260108062842 |
| 2025 Dahlk Hobbs HW ACM Lead Certs |
| 2024 Dahlk HW Hobbs Asbestos Certs |
| 2025 Dahlk Hobbs HW ACM Lead Certs |
| Hill West Lead Cert 2026 |
File details come from the government source that posted it. Updated .