Amendment_1.docx
DOCX document 54 KB Posted
- Attached to
- Alarm Services
- Solicitation number
- 19SP5018Q0005
- Issued by
-
Department of State US Embassy Madrid
About this file
Amendment 1
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Q&As_document_19SP5018Q0005_Alarm_Services_Solicitation.docx | DOCX document | |
| Alarms_solicitation_19SP5018Q0005.docx | DOCX document | |
| Invitation_Letter.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
1. CONTRACT ID CODE
PAGE OF PAGES
2. AMENDMENT/MODIFICATION NO.
3. EFFECTIVE DATE
04/20/2018
4. REQUISITION/PURCHASE REQ. NO.
5. PROJECT NO. (If applicable)
6. ISSUED BY CODE
7. ADMINISTERED BY (If other than Item 6) CODE
American Embassy Contracting Office Serrano, 75 – Box 27 28006 Madrid, Spain
Regional Security Officer American Embassy Serrano, 75 28006 Madrid
8. NAME AND ADDRESS OF CONTRACTOR (NO., street,city,county,State,and ZIP Code)
9a. AMENDMENT OF SOLICITATION NO.
19SP5018Q0005
To all prospective offerors
9b. DATED (SEE ITEM 11) March 23, 2018
10a. MODIFICATION OF CONTRACT/ORDER NO.
10b. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
[ X ] The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers [X ] is extended, [] is not extended Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing Items 8 and 15, and returning _1_ copies of the amendment;(b) By acknowledging receipt of this amendment on each copy of the offer submitted; or(c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers.
FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
| A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE |
| CONTRACT ORDER NO. IN ITEM 10A. |
| B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying |
| office, appropriation date, etc.) SET FORTH IN ITEM 14, PRSUANT TO THE AUTHORITY OF FAR 43.103(b) |
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor [ ] is not, [] is required to sign this document and return __ copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
The following changes are hereby made to RFQ 19SP5018Q005
a. Box 8 of SF-1449 is hereby changed to extend offer due date to May 7th , 2018 before 17:30
b. Delete Continuation To SF-1449, RFQ Number 19SP5018Q0005, Prices, Block 23 in its entirety and substitute in lieu thereof by the revised Continuation to SF1449 , RFQ Number 19SP5018Q0005, Prices, Block 23 shown in pages 3 thru 13.
c. Exhibit A is deleted in its entirety and it is substituted in lieu thereof by the revised Exhibit A.
d. Exhibit B is deleted in its entirety and it is substituted in lieu thereof by the revised Exhibit B.
e. Section 2.2. of CONTINUATION TO SF-1449, SCHEDULE OF SUPPLIES/SERVICES, BLOCK 20 is hereby revised to read as follows:
2.2. Installation of New Alarm Systems: Each individual newly installed alarm system must be completed, made operational and tested within maximum one (1) working day (9:00-17:00) for installations in single-floored premises. Installations in multi-floored sites must be completed, made operational and tested within a maximum of three (3) working days (09:00-17:00). If the Contractor needs to deviate from the one/three working day installation requirement, the request for deviation shall be in writing to the COR for evaluation and approval, and shall be at no additional cost to the USG
15A. NAME AND TITLE OF SIGNER (Type or print)
16A. NAME OF CONTRACTING OFFICER
Juan Carlos Ospina
15B. NAME OF CONTRACTOR/OFFEROR
| BY |
| (Signature of person authorized to sign) |
| 15C.DATE SIGNED |
| 16B. UNITED STATES OF AMERICA |
| BY /s/ |
| (Signature of Contracting Officer) |
| 16C.DATE SIGNED |
04/19/2018
SF30
f. Section 4. Evaluation factors Paragraph b) is hereby changed to read as follows:
Section 4 – Evaluation Factors
b) Technical Acceptability. The Government will thoroughly review those proposals remaining after the initial evaluation to determine technical acceptability. The Government will review Technical Acceptability by reviewing information submitted as part of Section 3, including a review of the schematics on the alarm system, review of the ability of the Contractor to monitor all alarm soundings for immediate reaction and availability of the necessary software to connect and disconnect the alarm remotely and proposed project manager. The Government may also review experience and past performance to verify quality of past performance Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
2.1. Base Year Prices
Option Term: Twelve (12) month period after Notice to Proceed:
| Item Number |
| Item Description |
| Estimated Quantity |
| Unit Price |
| Total |
| 2.1.1 |
| Activation and start-up of existing alarms, maintenance and testing of existing alarm systems. |
| 118 |
| each |
| 2.1.2 |
| Furnishing, installation, and testing of new alarm systems in multi-floored premises including, but not limited to, a central processor (50 zones), Zone expander, 50 zones LED keypad, cell-phone (GSM/GPRS), IP and/or fiber compatibility and land telephone line reporting, electrical connection, Ethernet module, battery back-up, glass break sensors (4), magnetic contact sensors (10), motion detectors (2), hard wired and (2) hand-held panic alarm buttons, exterior siren (1), key FOBs (2), interior siren (1) and strobe light, and all necessary wiring and cabling, and all maintenance and testing. |
Alarm systems must be compatible with DSL lines and/or ADSL lines using fiber optic technology.
| 5 |
| each |
| € |
| 2.1.3. |
| Furnishing, installation, and testing of new alarm systems including, but not limited to, a central processor (20 zones), Zone expander, 20 zones LED keypad, cell-phone (GSM/GPRS), IP and /or fiber compatibility and land telephone line reporting, electrical connection, Ethernet module, battery back-up (1), glass break sensors (2), magnetic contact sensors (4), motion detectors (1), hard wired and hand-held panic alarm buttons (2), exterior siren (1), interior siren (1) and strobe light, and all necessary wiring and cabling, and all maintenance and testing. |
Alarm systems must be compatible with DSL lines and/or ADSL lines using fiber optic technology.
| 10 |
| each |
| € |
| 2.1.4 |
| Monthly price for monitoring, reacts, etc., for all units |
| 118x12 |
| month |
| 0,00 € |
| 2.1.5. |
| Monthly fee for alarms connected via GSM/GPRS |
| 118x12 |
| month |
| 0,00 € |
| 2.1.6. |
| Maintenance and repair of installed alarm systems, including any parts needed to keep all alarms operational. |
| 118x12 |
| month |
| € |
| 2.1.7. |
| Removal of systems as described in PWS |
| 10 |
| each |
| € |
| 2.1.8. |
| VAT |
| included |
| 2.1.9. |
| Estimated Total Contract Price for the Base Year |
| € |
In the event that the quantity of alarm components to be installed in a specific location varies from the ones shown under Section 2.1 above, the cost for that system shall be adjusted based on firm fixed prices for alarm components and labor cost breakdown provided below. When alarm components are reutilized from a previous USG property, Contractor shall only charge labor cost based on below price breakdown.
Breakdown of costs for installation and testing of new alarm systems, with 50 zones for multi-floored properties
| Unit Price |
| Qty |
| Labor Cost |
| Total |
| central processor with 50zones |
| € |
| 1 |
| € |
| € |
| control Keypad 50 zones |
| € |
| 1 |
| € |
| € |
| GSM/GPRS cellphone card |
| € |
| 1 |
| € |
| € |
| Magnetic contact |
| € |
| 10 |
| € |
| € |
| Glass Break detector |
| € |
| 4 |
| € |
| € |
| Exterior siren |
| € |
| 1 |
| € |
| € |
| Interior siren |
| € |
| 1 |
| € |
| € |
| Wireless panic buttons |
| € |
| 2 |
| € |
| € |
| Wireless Key FOBs |
| € |
| 2 |
| € |
| € |
| Wireless receiver |
| € |
| 1 |
| € |
| € |
| Motion Detector |
| € |
| 2 |
| € |
| € |
| Battery |
| € |
| 1 |
| € |
| € |
| Ethernet module |
| € |
| 1 |
| € |
| € |
| Zone expander |
| € |
| 1 |
| € |
| € |
TOTAL
Breakdown of installation and testing of new alarm systems, with 20 zones
| Unit Price |
| Qty |
| Labor Cost |
| Total |
| central processor with 20 zones |
| € |
| 1 |
| € |
| € |
| control Keypad 20 zones |
| € |
| 1 |
| € |
| € |
| GSM/GPRS cellphone card |
| € |
| 1 |
| € |
| € |
| Magnetic contact |
| € |
| 2 |
| € |
| € |
| Interior siren |
| € |
| 1 |
| € |
| € |
| Wireless panic buttons |
| € |
| 2 |
| € |
| € |
| Wireless receiver for panic buttons |
| € |
| 1 |
| € |
| € |
| Motion Detector |
| € |
| 2 |
| € |
| € |
| Battery |
| € |
| 1 |
| € |
| € |
| Ethernet module |
| € |
| 1 |
| € |
| € |
| Zone expander |
| € |
| 1 |
| € |
| € |
TOTAL
2.1.10. Minimum/Maximum
The U.S. Government guarantees the following minimum and maximum orders under this contract during this base year:
Start-up, maintenance and testing of existing alarm systems (2.1.1.): minimum of ten (10); maximum of two hundred and fifty (250)
Furnishing, installation, maintenance and testing of new alarm systems (2.1.2.) (2.1.3): minimum of five (5); maximum of two hundred (200).
Removal of existing systems (2.1.8.): minimum of five (5); maximum of two hundred (200).
2.2. First Option Year Prices
Option Term: Twelve (12) month period after expiration of Base Year:
| Item Number |
| Item Description |
| Estimated Quantity |
| Unit Price |
| Total |
| 2.2.1 |
| Activation and start-up of existing alarms, maintenance and testing of existing alarm systems. |
| 0 |
| each |
| 0 |
| 2.2.2 |
| Furnishing, installation, and testing of new alarm systems in multi-floored premises including, but not limited to, a central processor (50 zones), Zone expander, 50 zones LED keypad, cell-phone (GSM/GPRS), IP and/or fiber compatibility and land telephone line reporting, electrical connection, Ethernet module, battery back-up, glass break sensors (4), magnetic contact sensors (10), motion detectors (2), hard wired and (2) hand-held panic alarm buttons, exterior siren (1), key FOBs (2), interior siren (1) and strobe light, and all necessary wiring and cabling, and all maintenance and testing. |
Alarm systems must be compatible with DSL lines and/or ADSL lines using fiber optic technology..
| 5 |
| each |
| € |
| 2.2.3 |
| Furnishing, installation, and testing of new alarm systems including, but not limited to, a central processor (20 zones), Zone expander, 20 zones LED keypad, cell-phone (GSM/GPRS), IP and /or fiber compatibility and land telephone line reporting, electrical connection, Ethernet module, battery back-up (1), glass break sensors (2), magnetic contact sensors (4), motion detectors (1), hard wired and hand-held panic alarm buttons (2), exterior siren (1), interior siren (1) and strobe light, and all necessary wiring and cabling, and all maintenance and testing. |
Alarm systems must be compatible with DSL lines and/or ADSL lines using fiber optic technology.
| 10 |
| each |
| 2.2.4 |
| Monthly price for monitoring, reacts, etc., for all units |
| 118x12 |
| month |
| 2.2.5. |
| Monthly fee for alarms connected via GSM/GPRS |
| 118x12 |
| month |
| 2.2.6. |
| Maintenance and repair of installed alarm systems, including any parts needed to keep all alarms operational. |
| 118x12 |
| month |
| 2.2.7. |
| Removal of systems as described in PWS |
| 10 |
| each |
| € |
| 2.2.8. |
| VAT |
| included |
| 2.2.9 |
| Estimated Total Contract Price for the First Option Year |
| € |
In the event that the quantity of alarm components to be installed in a specific location varies from the ones shown under Section 2.2 above, the cost for that system shall be adjusted based on firm fixed prices for alarm components and labor cost breakdown provided below. When alarm components are reutilized from a previous USG property, Contractor shall only charge labor cost based on below price breakdown.
Breakdown of costs for installation and testing of new alarm systems, with 50 zones for multi-floored properties
| Unit Price |
| Qty |
| Labor Cost |
| Total |
central processor with 50 zones control Keypad 50 zones
GSM/GPRS cellphone card
Magnetic contact
Glass Break detector
Exterior siren
Interior siren
Wireless panic buttons
Wireless Key FOBs
Wireless receiver for panic buttons
Motion Detector
Battery
| Ethernet module |
| € |
| 1 |
| € |
| € |
| Zone expander |
| € |
| 1 |
| € |
| € |
TOTAL
Breakdown of installation and with 20 zones
| Unit Price |
| Qty |
| Labor Cost |
| Total |
central processor with 20 zones control Keypad 20 zones
GSM/GPRS cellphone card
Magnetic contact
Glass Break detector
Interior siren
Wireless panic buttons
Wireless receiver for panic buttons
Motion Detector
Battery
| Ethernet module |
| € |
| 1 |
| € |
| € |
| Zone expander |
| € |
| 1 |
| € |
| € |
TOTAL
2.2.10. MINIMUM/MAXIMUM
The U.S. Government guarantees the following minimum and maximum orders under this contract during this first option year:
Furnishing, installation, maintenance and testing of new alarm systems (2.2.2.) and (2.2.3.): minimum of five (5); maximum of two hundred (200).
Removal of existing systems (2.2.8.): minimum of five (5).
2.3. Second Option Year Prices
Option Term: Twelve (12) month period after expiration of Base Year:
| Item Number |
| Item Description |
| Estimated Quantity |
| Unit Price |
| Total |
| 2.3.1 |
| Activation and start-up of existing alarms, maintenance and testing of existing alarm systems. |
| 0 |
| each |
| 2.3.2 |
| Furnishing, installation, and testing of new alarm systems in multi-floored premises including, but not limited to, a central processor (50 zones), Zone expander, 50 zones LED keypad, cell-phone (GSM/GPRS), IP and/or fiber compatibility and land telephone line reporting, electrical connection, Ethernet module, battery back-up, glass break sensors (4), magnetic contact sensors (10), motion detectors (2), hard wired and (2) hand-held panic alarm buttons, exterior siren (1), key FOBs (2), interior siren (1) and strobe light, and all necessary wiring and cabling, and all maintenance and testing. |
Alarm systems must be compatible with DSL lines and/or ADSL lines using fiber optic technology.
| 5 |
| each |
| 2.3.3 |
| Furnishing, installation, and testing of new alarm systems including, but not limited to, a central processor (20 zones), Zone expander, 20 zones LED keypad, cell-phone (GSM/GPRS), IP and /or fiber compatibility and land telephone line reporting, electrical connection, Ethernet module, battery back-up (1), glass break sensors (2), magnetic contact sensors (4), motion detectors (1), hard wired and hand-held panic alarm buttons (2), exterior siren (1), interior siren (1) and strobe light, and all necessary wiring and cabling, and all maintenance and testing. |
Alarm systems must be compatible with DSL lines and/or ADSL lines using fiber optic technology.
| 10 |
| each |
| 2.3.4 |
| Monthly price for monitoring, reacts, etc., for all units |
| 118x12 |
| month |
| 2.3.5. |
| Monthly fee for alarms connected via GSM/GPRS |
| 118x12 |
| month |
| 2.3.6. |
| Maintenance and repair of installed alarm systems, including any parts needed to keep all alarms operational. |
| 118x12 |
| month |
| 2.3.7. |
| Removal of systems as described in PWS |
| 10 |
| each |
| 2.3.8. |
| VAT |
| included |
| 2.3.9 |
| Estimated Total Contract Price for the Second Option Year |
In the event that the quantity of alarm components to be installed in a specific location varies from the ones shown under Section 2.3 above, the cost for that system shall be adjusted based on firm fixed prices for alarm components and labor cost breakdown provided below. When alarm components are reutilized from a previous USG property, Contractor shall only charge labor cost based on below price breakdown.
Breakdown of costs for installation and testing of new alarm systems, with 50 zones for multi-floored properties
| Unit Price |
| Qty |
| Labor Cost |
| Total € |
central processor with 50 zones control Keypad 50 zones
GSM/GPRS cellphone card
Magnetic contact
Glass Break detector
Exterior siren
Interior siren
Motion Detector
Wireless panic buttons
Wireless Key FOBs
Wireless receiver for panic buttons
Battery
| Ethernet module |
| € |
| 1 |
| € |
| € |
| Zone expander |
| € |
| 1 |
| € |
| € |
TOTAL
Breakdown of installation and with 20 zones
| Unit Price |
| Qty. |
| Labor Cost |
| Total |
central processor with 20 zones control Keypad 20 zones
GSM/GPRS cellphone card
Magnetic contact
Glass Break detector
Interior siren
Wireless panic buttons
Wireless receiver for panic buttons
Motion Detector
Battery
| Ethernet module |
| € |
| 1 |
| € |
| € |
| Zone expander |
| € |
| 1 |
| € |
| € |
TOTAL
2.3.10. MINIMUM/MAXIMUM
The U.S. Government guarantees the following minimum and maximum orders under this contract during this Second option year:
Furnishing, installation, maintenance and testing of new alarm systems (2.3.2.)(2.3.3.): minimum of five (5); maximum of two hundred (200).
Removal of existing systems (2.3.8.): minimum of five (5); maximum of two hundred (200).
2.4. Third Option Year Prices
Option Term: Twelve (12) month period after expiration of Base Year:
| Item Number |
| Item Description |
| Estimated Quantity |
| Unit Price € |
| Total € |
| 2.4.1 |
| Activation and start-up of existing alarms, maintenance and testing of existing alarm systems. |
| 0 |
| each |
| 0 |
| 2.4.2 |
| Furnishing, installation, and testing of new alarm systems in multi-floored premises including, but not limited to, a central processor (50 zones), Zone expander, 50 zones LED keypad, cell-phone (GSM/GPRS), IP and/or fiber compatibility and land telephone line reporting, electrical connection, Ethernet module, battery back-up, glass break sensors (4), magnetic contact sensors (10), motion detectors (2), hard wired and (2) hand-held panic alarm buttons, exterior siren (1), key FOBs (2), interior siren (1) and strobe light, and all necessary wiring and cabling, and all maintenance and testing. |
Alarm systems must be compatible with DSL lines and/or ADSL lines using fiber optic technology.
| 5 |
| each |
| 2.4.3 |
| Furnishing, installation, and testing of new alarm systems including, but not limited to, a central processor (20 zones), Zone expander, 20 zones LED keypad, cell-phone (GSM/GPRS), IP and /or fiber compatibility and land telephone line reporting, electrical connection, Ethernet module, battery back-up (1), glass break sensors (2), magnetic contact sensors (4), motion detectors (1), hard wired and hand-held panic alarm buttons (2), exterior siren (1), interior siren (1) and strobe light, and all necessary wiring and cabling, and all maintenance and testing. |
Alarm systems must be compatible with DSL lines and/or ADSL lines using fiber optic technology.
| 10 |
| each |
| 2.4.4 |
| Monthly price for monitoring, reacts, etc., for all units |
| 118x12 |
| month |
| 2.4.5. |
| Monthly fee for alarms connected via GSM/GPRS |
| 118x12 |
| month |
| 2.4.6. |
| Maintenance and repair of installed alarm systems, including any parts needed to keep all alarms operational. |
| 118x12 |
| month |
| 2.4.7. |
| Removal of systems as described in PWS |
| 10 |
| each |
| 2.4.8. |
| VAT |
| included |
| 2.4.9 |
| Estimated Total Contract Price for the Third Option Year |
In the event that the quantity of alarm components to be installed in a specific location varies from the ones shown under Section 2.4 above, the cost for that system shall be adjusted based on firm fixed prices for alarm components and labor cost breakdown provided below. When alarm components are reutilized from a previous USG property, Contractor shall only charge labor cost based on below price breakdown.
Breakdown of costs for installation and testing of new alarm systems, with 50 zones for multi-floored properties
| Unit Price |
| Qty |
| Labor Cost |
| Total |
central processor with 12 zones control Keypad 12 zones
GSM/GPRS cellphone card
Magnetic contact
Glass Break detector
Exterior siren
Interior siren
Wireless panic buttons
Wireless Key FOBs
Wireless receiver for panic buttons
Motion Detector
Battery
| Ethernet module |
| € |
| 1 |
| € |
| € |
| Zone expander |
| € |
| 1 |
| € |
| € |
TOTAL
Breakdown of installation and with 20 zones
| Unit Price |
| Qty |
| Labor Cost |
| Total |
central processor with 20 zones control Keypad 20 zones
GSM/GPRS cellphone card
Magnetic contact
Glass Break detector
Interior siren
Wireless panic buttons
Wireless receiver for panic buttons
Motion Detector
Battery
| Ethernet module |
| € |
| 1 |
| € |
| € |
| Zone expander |
| € |
| 1 |
| € |
| € |
TOTAL
2.4.10. MINIMUM/MAXIMUM
The U.S. Government guarantees the following minimum and maximum orders under this contract during this Third Option Year:
Furnishing, installation, maintenance and testing of new alarm systems (2.4.2.) (2.4.3.): minimum of five (5); maximum of two hundred) (200).
Removal of existing systems (2.4.8.): minimum of five (5); maximum of two hundred (200).
2.5. Fourth Option Year Prices
Option Term: Twelve (12) month period after expiration of Base Year:
| 2.5.1 |
| Activation and start-up of existing alarms, maintenance and testing of existing alarm systems. |
| 0 |
| each |
| € |
| 2.5.2 |
| Furnishing, installation, and testing of new alarm systems in multi-floored premises including, but not limited to, a central processor (50 zones), Zone expander, 50 zones LED keypad, cell-phone (GSM/GPRS), IP and/or fiber compatibility and land telephone line reporting, electrical connection, Ethernet module, battery back-up, glass break sensors (4), magnetic contact sensors (10), motion detectors (2), hard wired and (2) hand-held panic alarm buttons, exterior siren (1), key FOBs (2), interior siren (1) and strobe light, and all necessary wiring and cabling, and all maintenance and testing. |
Alarm systems must be compatible with DSL lines and/or ADSL lines using fiber optic technology.
| 5 |
| each |
| 2.5.3 |
| Furnishing, installation, and testing of new alarm systems including, but not limited to, a central processor (20 zones), Zone expander, 20 zones LED keypad, cell-phone (GSM/GPRS), IP and /or fiber compatibility and land telephone line reporting, electrical connection, Ethernet module, battery back-up (1), glass break sensors (2), magnetic contact sensors (4), motion detectors (1), hard wired and hand-held panic alarm buttons (2), exterior siren (1), interior siren (1) and strobe light, and all necessary wiring and cabling, and all maintenance and testing. |
Alarm systems must be compatible with DSL lines and/or ADSL lines using fiber optic technology.
| 10 |
| each |
| 2.5.4 |
| Monthly price for monitoring, reacts, etc., for all units |
| 118x12 |
| month |
| 2.5.5. |
| Monthly fee for alarms connected via GSM/GPRS |
| 118x12 |
| month |
| € |
| 2.5.6. |
| Maintenance and repair of installed alarm systems, including any parts needed to keep all alarms operational. |
| 118x12 |
| month |
| 2.5.7. |
| Removal of systems as described in PWS |
| 10 |
| 2.5.8. |
| VAT |
| included |
| 2.5.9 |
| Estimated Total Contract Price for the Fourth Option Year |
In the event that the quantity of alarm components to be installed in a specific location varies from the ones shown under Section 2.5 above, the cost for that system shall be adjusted based on firm fixed prices for alarm components and labor cost breakdown provided below. When alarm components are reutilized from a previous USG property, Contractor shall only charge labor cost based on below price breakdown.
Breakdown of costs for installation and testing of new alarm systems, with 50 zones for multi-floored properties
| Unit Price |
| Qty |
| Labor Cost |
| Total |
central processor with 50 zones control Keypad 50 zones
GSM/GPRS cellphone card
Magnetic contact
Glass Break detector
Exterior siren
Interior siren
Wireless panic buttons
Wireless Key FOBs
Wireless receiver for panic buttons
Motion Detector
Battery
| Ethernet module |
| € |
| 1 |
| Zone expander |
| € |
| 1 |
TOTAL
Breakdown of installation and with 12 zones
| Unit Price |
| Qty |
| Labor Cost |
| Total |
central processor with 20 zones control Keypad 20 zones
GSM/GPRS cellphone card
Magnetic contact
Glass Break detector
Interior siren
Wireless panic buttons
Wireless receiver for panic buttons
Motion Detector
Battery
| Ethernet module |
| € |
| 1 |
| Zone expander |
| € |
| 1 |
TOTAL
2.5.10. MINIMUM/MAXIMUM
The U.S. Government guarantees the following minimum and maximum orders under this contract during this fourth option year:
Furnishing, installation, maintenance and testing of new alarm systems (2.5.2.) (2.5.3.): minimum of five (5); maximum of two hundred) (200).
Removal of existing systems (2.5.8.): minimum of five (5); maximum of two hundred (200).
3. GRAND TOTAL PRICE
| Base Year Total |
| € |
| Option Year 1 Total |
| € |
| Option Year 2 Total |
| € |
| Option Year 3 Total |
| € |
| Option Year 4 Total |
| € |
| Grand Total of Base plus All Option Years |
| € |
EXHIBIT A - CONTRACTOR FURNISHED MATERIALS
The Contractor shall provide all equipment, materials, and supplies required to perform. Such items include, but are not limited to:
· Central Alarm Monitoring System using GSM/GPRS signals (not telephone land lines)
· Zone expanders
· LED key pads
· Radios
· Cellphones
· Ethernet modules
· Panic buttons/FOBs
· Electrical connections
· Long-life lithium battery back-ups for when power outages occur with replacements (24 hours minimum capacity)
· Glass break sensors
· Window/door magnetic contact sensors or motion detectors
· Hard wired and hand-held panic alarm buttons
· Key FOBs
· Wireless transmitters for panic buttons/Key FOBs
· All necessary wiring and cabling
· Uniforms and personal equipment
· Central alarm panels
· Sirens and strobe lights
· Operating instructions in English
· Alarm schematic/diagrams
· Marked vehicles for React Teams
· Command CFR
· Vehicles
The Contractor shall maintain sufficient spare parts, etc., for all Contractor-furnished materials to ensure uninterrupted services.
EXHIBIT B - GOVERNMENT FURNISHED PROPERTY
The following alarm systems currently installed in Government premises:
| ITEM DESCTIPTION |
| QTY |
| Alarm ADENCO 4140 |
| 1 |
| Alarm NETWOR NX6 |
| 1 |
| Alarms Galaxy Flex 20 |
| 71 |
| Alarm Galaxy Flex 100 |
| 1 |
| Alarms Galaxy Flex 50 |
| 2 |
| Alarms Vista 48 |
| 6 |
| Alarms Vista 12 |
| 36 |
TOTAL 118 alarms System.
The following alarm elements are currently in stock
| ITEM DESCTIPTION |
| QTY |
| VISTA 12 D |
| 3 |
| KEYPAD VISTA |
| 4 |
| EXTERIOR SIRENS |
| 4 |
| MAGNETIC CONTACTS |
| 5 |
| MICROPHONES |
| 5 |
| TRANSMTTER GSM / GPRS |
| 1 |
| MAGNETIC CONTACT (VR) |
| 2 |
| MOTION DETECTOR (VR) |
| 2 |
The Government will provide Identity badges to Contractor employees assigned to this contract
File details come from the government source that posted it.