Example Price Organization.xlsx
XLSX spreadsheet 13 KB Posted
- Solicitation number
- 19AQMM26Q0439
About this file
This is a pricing template spreadsheet for the HAARP large scale blast testing and fragmentation characterization solicitation (19AQMM26Q0439) issued by the Department of State Office of Acquisition Management. The template outlines six base test configurations and six optional test configurations for evaluating anti-ram barrier systems during simulated Vehicle Borne Improvised Explosive Device (VBIED) attacks.
The base test options include: AC-41-05 Bar Fence on DS-50 Knee Wall (Base 1), AC-41-06 Picket Fence on DS-50 Knee Wall (Base 2), DS-40 Anti-Climb & Ram Fence (Base 3), and DS-44 Steel Anti-Climb & Ram Fence (Base 4), with test lengths available at 30 feet, 45 feet, and 60 feet for most configurations. Optional configurations include AC-41-04 Tube Fence (Option 1), DS-43 Steel Anti-Climb & Ram Fence with Kickers (Option 2), Best Performing Fence with opaque cladding in stainless steel or aluminum (Option 3), Best Performing Fence with opaque metal plate material (Option 4), Best Performing Anti-Ram Fence with stainless steel cladding (Option 5), and Best Performing Anti-Ram Fence with lightweight material cladding (Option 6). Several test configurations can be combined where indicated, and the pricing template references detailed specifications in Appendix A with corresponding drawings in Appendix B. Vendors must follow this exact pricing format with no deviations accepted, and proposals are due by September 18, 2026 at 11:59 AM Eastern Standard Time to Richard Crum at crumrb@state.gov.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| QA for HAARP.docx | DOCX document | |
| 19AQMM26Q0439.pdf | ||
| attachment A SOW_ HAARP.docx | DOCX document | |
| Appendix B- Barrier Designs.zip | ZIP file |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Test Sample | Design Being Tested | Brief Description (See Appendix A for Details) | Potential to Combine tests | Length of Test sample Options | |||
| Drawings in Appendix B | |||||||
| Base 1 | AC-41-05 Bar Fence on top of DS-50 Knee Wall | 20x20mm Bars @ 65mm OC | N | B1.1: 30ft | $ | Base 30ft | 0 |
| B1.2: 45ft | $ | O1.1: 30ft | $ | ||||
| B1.3:60ft | $ | O2.1: 30ft | $ | ||||
| Base 2 | AC-41-06 Picket Fence on top of DS-50 Knee Wall | 50mm x 6mm Pickets @200mm OC | N | B2.1: 30ft | $ | O3.1: 30ft | $ |
| B2.2: 45ft | $ | O4.1: 30ft | $ | ||||
| B2.3:60ft | $ | O5.1: 30ft | $ | ||||
| Base 3 | DS-40 Anti- Climb & Ram Fence | 20x20mm Bars @ 130 mm OC w/ DN250 XS Pipes @ 1,720mm OC | Yes w/ base 4 or Option 2 | B3.1: 30ft | $ | O6.1: 30ft | $ |
| B3.2: 45ft | $ | ||||||
| B3.3:60ft | $ | ||||||
| Base 4 | DS-44 Steel Anti- Climb & Ram Fence | 100mm x 50mm x 6mm Tubes @ 175mm OC | Yes w/ base 3 or Option 2 | B4.1: 30ft | $ | Base 45 | 0 |
| B4.2: 45ft | $ | O1.2: 45ft | $ | ||||
| B4.3:60ft | $ | O2.2: 45ft | $ | ||||
| Option 1 | AC-41-04 Tube Fence on top of DS-50 Knee Wall | 38mm dia. x 3mm Tubes @150mm OC | N | O1.1: 30ft | $ | O3.2: 45ft | $ |
| O1.2: 45ft | $ | O4.2: 45ft | $ | ||||
| O1.3:60ft | $ | O5.2: 45ft | $ | ||||
| Option 2 | DS-43 Steel Anti- Climb & Ram Fence with Kickers | 100mm x 50mm x 6mm Tubes @ 175mm OC with Kickers @ 350mm OC | Yes w/ base 2 or base 3 | O2.1: 30ft | $ | O6.2: 45ft | $ |
| O2.2: 45ft | $ | ||||||
| O2.3:60ft | $ | Base 60 | 0 | ||||
| Option 3 | Best Performing Fence on knee wall with opaque cladding | E.g.: 24-gauge stainless steel 316L or Alum equivalent decorative panel on fence and steel plate behind knee wall | N | O3.1: 30ft | $ | O1.3:60ft | $ |
| O3.2: 45ft | $ | O2.3:60ft | $ | ||||
| O3.3:60ft | $ | O3.3:60ft | $ | ||||
| Option 4 | Best Performing Fence on knee wall with opaque cladding | E.g.: Metal plate material on fence and knee wall | N | O4.1: 30ft | $ | O4.3:60ft | $ |
| O4.2: 45ft | $ | O5.3:60ft | $ | ||||
| O4.3:60ft | $ | O6.3:60ft | $ | ||||
| Option 5 | Best Performing Anti-Ram Fence with Opaque cladding | E.g.: Stainless steel 316L or Alum equivalent decorative panel on fence | Yes w/ Option 6 | O5.1: 30ft | $ | ||
| O5.2: 45ft | $ | ||||||
| O5.3:60ft | $ | ||||||
| Option 6 | Best Performing Anti-Ram Fence with Opaque cladding | E.g.: Light weight material | Yes w/ Option 5 | O6.1: 30ft | $ | ||
| O6.2: 45ft | $ | ||||||
| O6.3:60ft | $ |