This solicitation requests proposals for operation of the Phoenix Job Corps Center located in Phoenix, Arizona. Services required include Outreach and Admissions, Career Transition Services, academic and career technical training, career readiness training, residential housing and support services for 353 students - 229 residential and 124 non-residential. The contractor must also provide Outreach and Admissions services in specified Arizona counties and ensure arrival of 640 students to the Phoenix center and 100 students to the Clearfield center annually. In addition, the contractor is responsible for Career Transition Services for Phoenix center graduates and former enrollees within their eligibility period, regardless of location. The issuing agency is the Department of Labor Employment and Training Administration.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PHOENIX
Job Corps Center Phoenix, AZ
Facility Planning Report Volume II
Supporting Data
Final May 2017
Department of Labor/ Office of Job Corps
PHOENIX
Job Corps Center Phoenix, AZ
Facility Planning Report Volume II
Supporting Data
Final May 2017
Trellis around the central court
VOLUME II - SUPPORTING DATA
EXECUTIVE SUMMARY
1.0 SITE LAYOUT AND PLANS
• Location Map
• Existing Site Plan
2.0 DESCRIPTIONS
• Buildings and Structures
• Space Utilization By Function
• NSF by Building
• Environmental Management Report
• Asbestos Report
• Radon Report
• Site Descriptions
• Building Descriptions
3.0 DEFICIENCIES
APPENDICES - CORRESPONDENCE AND REPORTS
Appendix A.
• Center Review Meeting Minutes
• Survey Brief
• Student Questionnaire
Appendix B.
• Life Safety Defi ciencies and List
Appendix C.
• O&M Defi ciencies List
Appendix D.
• Active Warranty List
Executive Summary
The facility survey for Phoenix Job Corps Center (Phoenix JCC) was completed the week of January 30, 2017. The information presented in Volume II, Supporting Data, represents the current status of the campus.
The information includes the following:
Existing site layout Overall status of existing building and structures Space utilization by building and function compared to recommended standards Status of environmental elements of the Center’s operations Details on the site and buildings and structures based on architectural, electrical, and mechanical survey and supporting documentation Presentation of the status of historical deficiencies and compilation of deficiencies documented through this survey Supporting documentation, as presented in the appendices of the center review meeting; survey brief and student questionnaire; life safety IA/IIA transmittal; and active warranties
Section 1.0 of this volume addresses site layout and plans while Section 2.0 presents details on the buildings and structures. Section 3.0 presents deficiencies and their status as well as new ones identified in this survey. The appendices provide additional information as noted below:
Appendix A. Survey Brief Questionnaire Appendix B. Life Safety Deficiencies and List Appendix C. O&M Deficiencies List Appendix D. Active Warranty Report
EXECUTIVE SUMMARY
1.0 - Site Layout and Plans
PHOENIX
JOB CORPS CENTER
PHOENIX, ARIZONA
PHOENIX JCC
10 MI50
2.0 - Descriptions
BUILDINGS AND STRUCTURES
00904 PHOENIX 05/31/2017
1Page: of Date:
0001 - MAIN BUILDING
0002 - VOCATIONAL BUILDING
0007 - CTS OFFICES
0008 - RECREATION
HALL/ADMINISTRATION
0010 - DORMITORY
0015 - COUNSELING
0016 - VOCATIONAL COMPLEX
BUILDING 1
0017 - VOCATIONAL COMPLEX
BUILDING 2
0018 - VOCATIONAL COMPLEX
BUILDING 3
0002A - PERGOLA (20Ft x 68Ft) 0008A - TRELLIS (120Ft x 15Ft) 0010A - LUGGAGE STORAGE 1 (10Ft x 12Ft) 0010B - LUGGAGE STORAGE 2 (10Ft x 19Ft) 0010C - TRELLIS 1 (10Ft x 20Ft) 0010D - TRELLIS 2 (10Ft x 20Ft) 0017A - FACILITIES STORAGE (20Ft x 40Ft) 0017B - STORAGE (18Ft x 32Ft)
Name GSF
62,460 11,080 4,800
10,050
34,690 1,583
12,551
3,759
3,647
1,360 1,800
Active Active Active Active
Active Active Active
Active
Active
Active Active Active
Active
Active Active Active
Active
StatusType
Building Building Building Building
Building Building Building
Building
Building
Structure Structure Structure
Structure
Structure Structure Structure
Structure
Use Group Built Flrs Const
Bus/Assem Business Bus/Assem Assembly
Residential Business Business
Business
Business
Assembly Assembly Storage
Storage
Assembly Assembly Storage
Storage
Fair Fair
Good Good
Good Good Good
Good
Good
Fair Good Good
Good
Good Good Good
Good
ConditionAsset Number
0090400002 0090400003 0090400017 0090400018
0090400019 0090400023 0090408043
0090408044
0090408045
0090408048 0090408047 0090408039
0090408040
0090408041 0090408042 0090408046
0090408049
9 144,620
8 5,246
17 149,866
Buildings
Structures
Total
GSF
GSF
GSF
Summary
05/31/2017
Space Utilization By Function 00904 Phoenix Page: 1 of Date:
HOUSING
EDUCATION
FOOD SERVICE
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
Resident Men Resident Women Total Residents
Residents 229 Non Residents 124
353Total Students
(229)
(353)
(353)
DIFFERENCE
24,732
21,850
6,354
24,637
35,977
5,381
Lounge Other Shower/Toilet Sleeping excl. SPD(56 rooms; 229 beds) Storage
Academic (353) Non-Academic
20 -- Carpentry + 20 -- Cement Masonry + 60 -- Cert. Nursing Asst.
30 -- Computer Service Tech.
24 -- Facilities Maint. and Const. + 30 -- Medical Assistant 30 -- Office Administration 20 -- Plastering + 60 -- Security Services
Vocational Theory (84)
Dining (2 Servings) Food Preparation Food Storage
4,146 2,795 2,494
14,445
6,180 8,087
3,132 2,974 1,085 1,584 2,985 2,953 2,143 3,047 1,507
2,993
1,870
2,290 1,832 2,748
16,488 1,374
3,530 3,530
1,500 1,500 2,400
1,800
1,350 1,500 2,100
2,824 2,118 1,412
1,856 -254
-2,043 -617
2,650 4,557
1,632 1,474 -1,315
1,185 2,053
1,547
-593
-540
-1,600
Vocations
-95
14,127
-973
05/31/2017
Space Utilization By Function 00904 Phoenix Page: 2 of Date:
RECREATION
MEDICAL/DENTAL
ADMINISTRATION
STORAGE/SUPPORT
VACANT
SUGGESTED
NSF/
ENROLLEE
SUGGESTED
TOTAL
NSF
ACTUAL
TOTAL
NSF
TYPE OF SPACE
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
SUB TOTAL
TOTAL 233.53 82,436 102,452
(353)
(353)
(353)
(353)
(0)
DIFFERENCE
144,620
0.71
TOTAL GSF
NET TO GROSS RATIO
13,310
2,070
7,060
17,052
3,309
6,974
8,611
Arts & Crafts Canteen Gymnasium Men's Exercise Room Miscellaneous Recreation Multipurpose Room Pool Hall Recreation Office Recreation Storage Women's Exercise Room
Medical/Dental
Administration
Operations & Maintenance Warehouse
Under Renovation - Education Vacant
5.86
1,092
4,793
3,040 3,652
2,017
3,309
6,974
3,091 5,520
2,070
2,824 4,236
1,239
-86
1,284
RESIDENT
NON-RESIDENT
(229)
(124) 15
50 11,450 1,860
3,742
1,239
-86
1,551
20,016
Net Square Footage By Building Date: 05/31/2017 Page: 1
Center: PHOENIX (00904) of 4
HOUSING
Sleeping excl. SPD
Lounge
Storage
Shower/Toilet
Other
Function Suggested
NSF
12,562 1,883
3,482
2,154
2,795
0010 - DORMITORY
0001 - MAIN BUILDING
0001 - MAIN BUILDING
0010 - DORMITORY
0010 - DORMITORY
0001 - MAIN BUILDING
0010 - DORMITORY
0001 - MAIN BUILDING
0010 - DORMITORY
Bldg Name Actual NSF Difference
14,445
4,146
2,494
2,795
Sub Total: 24,637
16,488
2,290
1,374
2,748
1,832
24,732
-2,043
1,856
-617
-254
( 229
-95
48 rooms; 213 beds 8 rooms; 16 beds
Page: 2
Center: PHOENIX (00904) of 4
EDUCATION
Academic
Vocational Theory (84)
Carpentry
Cement Masonry
Plastering
Computer Service Tech.
Facilities Maint. and Const.
Medical Assistant
Security Services
Non-Academic
Office Administration
Cert. Nursing Asst.
Function Suggested
NSF
1,118 3,166
1,210
3,132
2,974
3,047
2,985
1,740 1,213
1,507
1,134
1,343 2,313
1,263
2,143
1,085
0002 - VOCATIONAL BUILDING
0001 - MAIN BUILDING
0008 - RECREATION HALL/ADMINISTRATION
0001 - MAIN BUILDING
0017 - VOCATIONAL COMPLEX BUILDING 2
0017 - VOCATIONAL COMPLEX BUILDING 2
0016 - VOCATIONAL COMPLEX BUILDING 1
0016 - VOCATIONAL COMPLEX BUILDING 1
0002 - VOCATIONAL BUILDING
0018 - VOCATIONAL COMPLEX BUILDING 3
0016 - VOCATIONAL COMPLEX BUILDING 1
0001 - MAIN BUILDING
0018 - VOCATIONAL COMPLEX BUILDING 3
0002 - VOCATIONAL BUILDING
0018 - VOCATIONAL COMPLEX BUILDING 3
0001 - MAIN BUILDING
0007 - CTS OFFICES
0001 - MAIN BUILDING
0002 - VOCATIONAL BUILDING
0001 - MAIN BUILDING
0010 - DORMITORY
0010 - DORMITORY
0008 - RECREATION HALL/ADMINISTRATION
0015 - COUNSELING
0001 - MAIN BUILDING
0001 - MAIN BUILDING
Bldg Name Actual NSF Difference
6,180
3,132
2,974
3,047
1,584
2,985
2,953
1,507
8,087
2,143
1,085
Sub Total: 35,977
3,530
1,500
1,500
1,500
1,800
2,100
3,530
1,350
2,400
21,850
2,650
-540
1,632
1,474
1,547
1,185
2,053
-593
4,557
-1,315
( 353
14,127
Page: 3
Center: PHOENIX (00904) of 4
FOOD SERVICE
RECREATION
MEDICAL/DENTAL
Dining (2 Servings)
Food Preparation
Food Storage
Multipurpose Room
Arts & Crafts
Gymnasium
Miscellaneous Recreation
Pool Hall
Canteen
Men's Exercise Room
Women's Exercise Room
Recreation Storage
Recreation Office
Medical/Dental
Function Suggested
NSF
2,993
1,870
2,963
1,092
4,793
3,652
1,579
3,309
0001 - MAIN BUILDING
0001 - MAIN BUILDING
0001 - MAIN BUILDING
0010 - DORMITORY
0007 - CTS OFFICES
0001 - MAIN BUILDING
0001 - MAIN BUILDING
0001 - MAIN BUILDING
0008 - RECREATION HALL/ADMINISTRATION
0008 - RECREATION HALL/ADMINISTRATION
0001 - MAIN BUILDING
0001 - MAIN BUILDING
0001 - MAIN BUILDING
0008 - RECREATION HALL/ADMINISTRATION
0010 - DORMITORY
0008 - RECREATION HALL/ADMINISTRATION
0001 - MAIN BUILDING
0001 - MAIN BUILDING
Bldg Name Actual NSF Difference
2,993
1,870
3,040
1,092
4,793
3,652
2,017
3,309
Sub Total:
Sub Total:
Sub Total:
5,381
17,052
3,309
2,824
2,118
1,412
2,070
6,354
13,310
2,070
-1,600
1,239
-973
3,742
1,239
Page: 4
Center: PHOENIX (00904) of 4
ADMINISTRATION
STORAGE/SUPPORT
VACANT
Administration
Warehouse
Operations & Maintenance
Vacant
Under Renovation - Education
Function Suggested
NSF
1,033 1,134
4,728
2,106
2,810
3,049
0002 - VOCATIONAL BUILDING
0008 - RECREATION HALL/ADMINISTRATION
0010 - DORMITORY
0001 - MAIN BUILDING
0002 - VOCATIONAL BUILDING
0008 - RECREATION HALL/ADMINISTRATION
0016 - VOCATIONAL COMPLEX BUILDING 1
0002 - VOCATIONAL BUILDING
0001 - MAIN BUILDING
0002 - VOCATIONAL BUILDING
0008 - RECREATION HALL/ADMINISTRATION
0002 - VOCATIONAL BUILDING
Bldg Name Actual NSF Difference
6,974
5,520
3,091
Sub Total:
Sub Total:
Sub Total:
6,974
8,611
7,060
4,236
2,824
7,060
7,060
-86
1,284
-86
1,551
Environmental Management Report Center: PHOENIX (00904)
Page: 1 Date: 05/31/2017 of 1
SOLID & HAZARDOUS WASTE MANAGEMENT (RCRA)
Commercial Waste Service
HAZARDOUS MATERIALS STORAGE (EPCRA)
No Pre-apprenticeship Vocational Building
Oil-based paints/stains, organic solvent, paint thinner, wax stripper Yes
PETROLEUM UNDERGROUND STORAGE TANKS (RCRA)
N/A0
PETROLEUM ABOVEGROUND STORAGE TANKS (CWA)
ASBESTOS AND PCB MANAGEMENT (TSCA)
AIR POLLUTION CONTROL (CAA)
N/A None
Non-Attainment
Solid Waste Disposal :
Hazardous Waste Generator :
Hazardous Waste ID :
Generator Classification :
Hazardous Materials Storage :
Hazardous Materials ID :
HazMat Storage Area :
HazMat Spill Response Plan :
Number of Regulated USTs :
Number of Un-regulated USTs :
Local Hazardous Use Permit :
LEPC Notification :
EPA Generator ID Number :
Hazardous Waste Disposal :
RCRA Compliance
ID LocationFuel Type Capacity
Number of ASTs :
Asbestos Survey Date :
Asbestos Type :
Asbestos Coordinator :
Coordinator Training Date:
Custodial/Maintenance Training :
AHERA Regulated :
Management Plan Approval :
PCB Transformer Testing :
PCB Transformers :
PCB-Contaminated Transformers :
Transformers Labelled :
Regional Air Quality :
Permitted Air Pollution Source :
Source Description :
Waste Management, Inc.
Yes Organic solvent (2 gals/yr), paint thinner (3 gals/yr)
Conditionally Exempt Small Quantity Generator N/A Commercial Hazardous Waste Disposal Service Safety-Kleen, Chandler, AZ
No No
Overfill Leak Corrosion
SPCC Plan Required : SPCC Plan Completed :
No N/A
10/11/1990 Friable/Non-Friable Troy Lacy 07/06/1992 Yes No N/A No No
CO, Ozone, PM-10
ID Fuel Type Capacity Location Overfill
Prevention Secondary ContainmentTank Status
Tank Status Prevention/Detection
Asbestos-Containing Materials Inventory
Date: 05/31/2017Center : Phoenix (00904) Page: 1 of 1
Roof Repair/Replacement Roof Repair/Replacement Floor Finishes Floor Finishes Roof Repair/Replacement Heating Floor Finishes Floor Finishes Floor Finishes Floor Finishes Floor Finishes Floor Finishes Floor Finishes
Ceiling Finishes Ceiling Finishes Floor Finishes Roof Repair/Replacement Roof Repair/Replacement
Bldg System
Bldg System
Roofing felt/asphalt shingles Roof flashing Mastic beneath 12x12 tile 12x12 floor tile, off-white Built-up roofing Pipe fitting insulation 12x12 floor tile, tan/orange 12x12 tile, tan (covered) 12x12 floor tile, brown 12x12 floor tile, grey 12x12 floor tile, brown 12x12 floor tile, tan 12x12 tile, white (covered)
Acoustical plaster Acoustical plaster 12x12 floor tile, beige Built-up roofing material Roof flashing
Category Description
Category Description
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Ea.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Sq. Ft.
Location
Location
Unit
Unit
Quantity
Quantity
Roof sections 7, 8 Building perimeter See above locations 1st fl., storage rm.
Roof section 3 Above 1st fl. hall 1st fl., gym hallway 1st fl., common area 1st fl., elec. room 1st fl., fire equip.
Gymnasium 1st fl., print shop 1st fl., back hall
2nd fl., maint. area 1st fl., maint. area 2nd fl., maint. area Roof, maint. area Roof, maint. area
Building :
Building :
0001 - MAIN BUILDING
0002 - VOCATIONAL BUILDING
Radon
Page: 1 of 1
0001 - MAIN BUILDING
0002 - VOCATIONAL BUILDING
0007 - CTS OFFICES
0008 - RECREATION HALL/ADMINISTRATION
0010 - DORMITORY
0015 - COUNSELING
0016 - VOCATIONAL COMPLEX BUILDING 1
0017 - VOCATIONAL COMPLEX BUILDING 2
0018 - VOCATIONAL COMPLEX BUILDING 3
Bldg Name
08/11/1992
06/06/1990
06/06/1990
06/06/1990
06/06/1990
Test Date
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Radon Testing
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
< 4 pCi
Test Result
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Mitigation Mitigation Date
RADON EXPLANATORY NOTES
The US Environmental Protection Agency (EPA) has established a radon action level of 4.0 picoCuries per liter (pCi/L). Occupied buildings with radon concentrations less than 4.0 pCi/L do not require radon mitigation; un-occupied buildings, or those buildings which are occupied only infrequently for brief periods of time, also do not require radon mitigation. Occupied buildings with radon concentrations greater than
4.0 pCi/L require radon mitigation and verification of radon reductions as soon as possible, with priority given to dormitories and student recreation buildings. Occupied buildings with radon concentrations greater than 20.0 pCi/L should be considered significant radon exposure hazards, and priority for mitigation should be given to buildings with these highly elevated radon concentrations.
Radon mitigation techniques include: (1) adjustment of the building HVAC system to create a positive pressure within the building; (2) sealing of foundation wall cracks, penetrations, or other openings;
(3) sealing crawlspace openings and sump pits; (4) installing an active subslab depressurization (ASD) system.
Site Description
Aerial view of Phoenix JCC
Page: 1 Date: 05/31/2017 of 5
Comments:
Paving Type for Roads & Parking
The City owns the roads and sidewalks. The Center is located on several city blocks, however, there are no crosswalks across the roads for the students to use while circulating around the Center. Parking is provided by Center owned/leased lots (two blocks west of main campus) including street parking.
Paving Type for Sidewalks
Asphalt Concrete
Comments:
Topography Buildings and Structures
Center is not fully enclosed by fencing. The campus has several courtyards paved with a combination of exposed aggregate concrete pavers, decorative brick and plain concrete pavers. Plants, trellises, benches and tables are located within these courtyards. The dormitory courtyard has extensive landscape, water features, a series of ponds and an outdoor grill. The soft vocation, education, recreation, administration and dormitory blocks have perimeter masonry fences with stucco finish. The hard vocation and new parking blocks have perimeter chain link fences.
ROADS, PARKING & SIDEWALKS
Water Source Water Authority Service Meter On-Site Treatment Plant
1. Water System
Treatment Type Storage Type Storage Capacity(Gallons)
NoIndividualCity of PhoenixPublic Water Authority
Water Softener 0None
Water softeners treat the Dormitory water supply and Main building water supply.Comments:
Number of Deficiencies = 1
Number of Deficiencies = 1
SITE FEATURES
UTILITIES
Buildings Structures9 8Flat
Surrounding
Outdoor Recreation
Urban
None
Dormitory Perimeter
Hard Vocations
Parking
Soft Vocations/Administration
Stone/Concrete
Chain Link
Chain Link
Stone/Concrete
Location Type
Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good Ownership
Roads & Parking Adequate Roads & Parking Condition Sidewalks Adequate Sidewalk Condition Yes Good Yes Good
Number of Deficiencies = 1
Fencing
Other Features
Page: 2 Date: 05/31/2017 of 5
Comments:
Fire Hydrants On-Site Water Supply Storage Capacity
(Gallons) Pressure Source FD Response Time (Minutes)
Yes 0 10None Municipal
There is a fire department at N 4th Ave and W Van Buren Street, approximately 1.2 miles from the Center and about 10 minutes response time. There are city owned fire hydrants on nearly every street corner surrounding the campus.
Sewage Treatment Flow
Utility
Publicly Owned Treatment Works
Center
Gravity
Maintenance ResponsibilityOwnership
Comments: There are two gas meters at the campus.
Southwest Gas
3. Sanitary Sewer System/ Sewage Treatment Plant
5. Fuel Distribution System
2. Fire Protection System
Separate Loop
No
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Utility Utility Yes Good
System Capacity Adequate System Condition
Yes Good
4. Storm Water System Number of Deficiencies = 1
Drain Type On-Site Storm Water Management
Surface Runoff N/A
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center No GoodCenter
Gas Company Metering
Individual
Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good
6. Central Plant: None
Page: 3 Date: 05/31/2017 of 5
Comments:
Electric Company PCB Trans.
Transformer Mounting Transformer Ownership
Systems Ownership Maintenance Responsibility
Arizona Public Service Co.
Services enter the Center at multiple locations. Main Building 1 has two services. The first service is delivered from a 3x75 kVA pole-mounted transformer bank on Second Street which serves the west half of Building 1. The second service is delivered from a power pole on Third Street east of the campus to a pad-mounted transformer in the back of Building 1. This service serves the east half of the building. Each service is metered separately. Vocational Building 2 has two services, one from the north and one from the east. The service from the north is delivered from a 50 and 100 kVA pole-mounted transformer bank on Buchanan Street. The service from the east is delivered from a 75 kVA and 50 kVA pole-mounted transformer bank on Third Street. Each service is metered separately.
Buildings 7 and 8 are provided by 120/240V, 1-phase services from a power pole on Third Street with a separate meter and also each of the buildings has additional service provided respectively from Buildings 2 and 1. Dormitory Building 10 service is delivered from a power pole on Buchanan Street to a pad-mounted transformer located in the back of the building. This building has its own meter. Building 15 is sub-fed from Building 2. Vocational Complex Buildings 16, 17 and 18 are served by a 225 kVA pad-mounted transformer adjacent to Building 16. These three buildings share the same meter. Buildings 1, 10, 16, 17, and 18 have 120/208V, 3-phase, 4 wire services. Building 2 has 120/240V, 3-phase, 4 wire services. Buildings 7, 8, and 15 have main 120/240V, 1-phase, 3 wire services.
Buildings 7 and 8 have additional 3-phase services (240V and 208V) respectively. Lightning protection is provided on the roofs of Buildings 16, 17, and 18. The 200A manual double-through transfer switch with CAM Lock for generator connection provides for the T-Mobile cellphone equipment, located on the upper roof of Building 1.
Pole and Pad Utility
Utility Utility
No
7.2/4.16 kV, 3-Phase, 4 Wire
208/120 V, 3-Ph, 4 W and 120/240V, 3-Ph, 4 WOverhead & Underground
Overhead & UndergroundPrimary Service
Secondary Service
Distribution Characteristics
Number of Deficiencies = 27. Electrical (Service)
Transformer Maint Resp
Utility
System Capacity Adequate System Condition
Yes Fair
Generator
None
8. Electrical (Site Lighting)
Roadways Parking Walkways Building Outdoor Sports
Mounting
Control
None Pole Pole Building None
None Photocell, Time Clock Photocell, Time Clock Photocell, Time Clock None
System Ownership Maintenance Responsibility System Capacity Adequate System Condition
Center Center Yes Good
Comments: Site lighting includes building and two pole-mounted fixtures (at the front of Building 10), which are controlled by photocells and time clocks at the respective buildings. The Center owns and maintains this site lighting. Pole-mounted street lights belong to and maintained by the local electrical utility, and complement the perimeter center lighting. There are two remote parking lots for staff and student across from First Street west of the campus. Site lighting at this location is controlled by the fixture-mounted photocells, maintained by the Center, and served from a 100A MCB with a utility meter.
ATS MTS
No No
Number of Deficiencies = 1
Metering Individual
Page: 4 Date: 05/31/2017 of 5
Comments:
Telephone Company
On-site Line Owner
The telephone service entrance/ DEMARK point are located in the basement telephone room in Building 1. Main data closet (MC) housing Cisco distribution equipment and telecommunication closet (TC) are located at the first floor of Building 1. The Centers data layout is based on four servers (two for staff and two for student applications) located three in the MC and one in TC. Data equipment in MC is provided by power backup by UPS units, which buffers the power surges and drops in the line voltage up to 20 minutes before an automated shut down. Long distance telephone service is provided by Job Corps Data Center (JCDC). The telephone system including local and full DSI DID Trucking Service is provided by Integra Telecom Communication. There are a total of 200 available phone lines at the Center, with 135 Voice digital desk top phones, 11 analog fax lines, and 54 spare lines. The data from MC in Building 1 through a Cisco 6506 switch and two 3900 series is distributed to eight other building (3560 series switches ) overhead via fiber optic cable. Four fire alarm systems on the Center are remotely monitored from the security area in Building 1. Two systems are located in Buildings 1 and 10 respectively, one located in Building 7 and monitor devices in Buildings 2, 15, and 8, and one located in Building 16 and monitors devices in Buildings 17 and 18. Mitrone EST fire alarm systems are provided in Buildings 1, 7, and 10, and Silent Knight system in Building 16. There are four surveillance cameras, one at the northwest corner of Building 7 scanning the Center's front parking and main entrance from Buchanan Street, one on the west exterior wall of Building 1, scanning the Center's west entrance from Second Street to the Alley, one at the main entrance and one in the lobby of Building 1. The cameras are monitored from color monitor in the security office in Building 1.
Magnetic door alarms in Buildings 1 and 10 and direct TV in Buildings 1 , 8 and 10.
Electric LightWave
Maint. Responsibility
Center Center
CCTV, Magnetic Door Alarms, Motion Sensors
9. Electrical (Communication/Alarm/Security)
Yes
Central
VOIP
System Capacity Adequate System Condition
GoodYes
Number of Deficiencies = 9
STORAGE TANKS: None
Fire Alarm Security
Page: 5 Date: 05/31/2017 of 5
ACCESSIBILITY
Yes
The site is flat and most sidewalks have curb cuts.Comments:
UnknownNoNoNo
Nationally Registered Site
Site Eligible for National Register
Located in Historic District
Archaeological Significance
Earthquake Risk
Medium Medium LowMedium LowIBC Low
LightningEarthquake Def. Authority Flooding Tornado Hurricane Forest
Fire
Number of Deficiencies = 6
Accessible Parking: Accessible Slope:
Yes
Curb Cuts:
Yes
Ramps:
N/AYes
Site Accessible Route:
GENERAL SITE CONDITION
Rating X Good Fair Poor
HISTORIC PRESERVATION
NATURAL HAZARDS
The site condition is not impacting the functional use of the facilities.
The site condition IS impacting the functional use of the facilities.
The site condition IS SIGNIFICANTLY impacting the functional use of the facilities.
Active Energy Use Reduction Program
Active Water Use Reduction Program
Approximate or Measured Waste Recycled
Use of School Dude or CMMS for Preventative Maintenance
Green Purchasing Policy Practiced
Site Stormwater Absorption Measures in Place
Center has Onsite Renewable Energy (PV or Wind)
Center has a Chartered Green Committee & Roster
Center Uses Green Cleaning Practices
SUSTAINABILITY
Comments: The Center is revising their recycling program so they can help Job Corps meet the 50% requirement by 2017.
Yes
Yes
NO
Yes
Yes
Yes
Yes
Yes
7 %
Building Descriptions and Structures
BUILDING 1 - MAIN BUILDING
Building Descriptions
Page: 1 of 48
Building: 0001 - MAIN BUILDING
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Concrete/CMU Concrete
The floor construction is concrete.
Brick Masonry EIFS Stucco
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors Bus/Assem 62,460 41,726 5 Owned 1925 Not Evaluated
Comments: The exterior ramp located outside the south exit of the gym is used for egress only. The first floor public restrooms are not accessible. Upper floor restrooms are accessible except 4th floor dormitory restrooms.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
No
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2. Number of Deficiencies = 2
Material
Asbestos: Yes
The remaining life expectancy is based on visual observation and condition of the roof during the January 2017 Facility Survey. This roof covers the one story portion of the building, with nine different roof sections, which have a spray polyurethane foam (SPF) roofing system that is in poor condition.
The remaining life expectancy is based on visual observation and condition of the roof during the January 2017 Facility Survey.
Drainage Year Life
Remaining Type Area Served
Spray Polyurethane Foam
(SPF)
Rolled Asphalt
Interior Roof Drains
Interior Roof Drains
Flat
Flat
One-story building
Four-story portion
Number of Deficiencies = 1
Comments:
Comments:
3. Roof
Entire Building
Area Served
Comments:
Page: 2 of 48
Building: 0001 - MAIN BUILDING
Wall Roof None Batt
Comments: The building has the original single pane, non-insulated windows.
INTERIOR FINISH
Carpet Ceramic Tile Concrete Epoxy Resin Rubber Vinyl Tile Wood
CMU Ceramic Tile Drywall Fiberglass Panel Plaster Vinyl Wall Covering Wood Paneling
Metal Unit - Metal Frame Wood Cutch Unit - Wood Frame
Wood Unit - Wood Frame
VERTICAL CIRCULATION
Concrete Stairs Elevator Ramp Wood Stairs Comments: A small passenger elevator serves the four story section of the building located at the east side.
Concrete stairs and ramp leads to the building entrance.
Metal Unit - Metal Frame
Awning Units - Steel Frame; Single Glazing; Fixed - Steel Frame; Single Glazing;
Sliding - Aluminum Frame; Double Glazing; Sliding - Aluminum Frame; Single Glazing;
Sliding - Steel Frame; Single Glazing;
Acoustical Tile Exposed Structure Gypsum Board Plaster
Number of Deficiencies = 1
Insulation4.
Exterior Doors5. Number of Deficiencies = 2
Windows6. Number of Deficiencies = 2
Floors1. Asbestos: Yes Number of Deficiencies = 4
Interior Walls2. Number of Deficiencies = 1
3. Number of Deficiencies = 1
Interior Doors4. Number of Deficiencies = 1
Ceilings
Page: 3 of 48
Building: 0001 - MAIN BUILDING
Mechanical
Mechanical
Toilet/Shower
Kitchen
Ventilation Area Served
Split Direct Expansion (Air
Source)
Packaged Heat Pump (Air
Source)
Single Duct
Single Duct
Refrigerant
None
Electric
Electronic
Natural
Mechanical
None
None
Electronic Equipment
Room
Entire Building
Exhaust Ventilation
A split DX air conditioner serves the computer room located in the medical/dental area.
This building has 24 packaged heat pumps manufactured by Trane, York, and Arcoaire. Eight are 15 ton units. Three are 10 ton units. Two are 7.5 ton units. Nine are 5 ton units. One is a 4 ton unit. One is a 3 ton unit.
Comments:
Comments:
Number of Deficiencies = 2
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
A Goettl model VGLP 5-T electric furnace serves the weight room area.
This building has 24 packaged heat pumps manufactured by Trane, York, and Arcoaire. Eight are 15 ton units. Three are 10 ton units. Two are 7.5 ton units. Nine are 5 ton units. One is a 4 ton unit. One is a 3 ton unit. A typical Trane packaged rooftop unit is model WCH180B300FA manufactured in 11/2002.
Comments:
Comments:
HVAC
Heat1. Asbestos: Yes
Electric Furnace
Split Heat Pump (Air
Source)
Single Duct
Single Duct
None
None
Electric
Electronic
Natural
Mechanical
None
None
Recreation Area
Entire Building
Ventilation2.
System Type
Number of Deficiencies = 1
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
3. Number of Deficiencies = 1Air Conditioning
Page: 4 of 48
Building: 0001 - MAIN BUILDING
The gymnasium showers are provided with hot water from an A.O. Smith model DRE 120 917 electric water heater with two Raypak 115 gallon insulated storage tanks. The kitchen is provided with hot water by an A.O. Smith model BTR 199 118, manufactured on 12/09/2009. Kitchen hot water is treated with a water softener. The upper floors are provided with hot water from a Raypak model W3-1083 hot water boiler.
Comments:
Comments:
Cast-Iron Outdoor Cast-Iron
The kitchen is served by bio-chemical digester type grease interceptors.
Electric Water Cooler Fixed Emergency Eyewash Hose Bibb Lavatory Shower Sink Urinal Water Closet (Flush Valve) Waterless Urinal
Gas (Natural)
Wet None ABC Type Fire Extinguisher, K Type Fire Extinguisher, Wet Chemical
Comments: Only the basement center maintenance area is sprinklered.
Galvanized Steel and Copper
Galvanized Steel and Copper
Electric Water Softener No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING Number of Deficiencies = 1
Water Distribution1.
Sanitary Distribution2.
Fixtures3. Number of Deficiencies = 3
Fuel Distribution4.
Number of Deficiencies = 2FIRE PROTECTION
Location UL300 Compliance Status Kitchen Compliant
UL300 COMMERCIAL KITCHEN HOOD FIRE SUPPRESSION
Page: 5 of 48
Building: 0001 - MAIN BUILDING
Comments: The building has two services. The first service is brought from the west via 3x75 kVA pole-mounted transformers on Second Street to an 800A MDS switchboard (3/26/1976) located in the gymnasium electrical room, and serves loads in the west half of the building (the gymnasium and academic education), and a 400A MCB distribution panel on the roof, providing for HVAC loads at the west and a 200A panel in Building 8. The second service brought from a power pole on Third Street to a pad-mounted transformer at the back of the building, which energizes a 3000A switchgear adjacent to the transformer. The 1200A fused disconnect switch in 3000A switchgear feeds one 1200A MLO switchboard (12/24/1969) through a 1200A fused disconnect, both located in the cafeteria electrical room and serve the east half of the building (the cafeteria and administration area), and one 1200A MLO switchboard on the roof. Each service has its own utility meter. Owner meter is provided at the 1200A switchboard.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Halogen High Intensity Discharge (HID) Comments: Exterior lighting is provided by surrounding area pole-mounted light fixtures which are controlled by time clock and photocells.
Switchboard 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
ELECTRICAL SERVICES Number of Deficiencies = 13
Exterior Lighting1.
LIGHTING
Page: 6 of 48
Building: 0001 - MAIN BUILDING
Comments: Recorded footcandle levels include natural light contribution.
Comments: Combination emergency light exit sign fixtures are also provided.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
High Intensity Discharge (HID)
T8 - Fluorescent
CFL+T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Offices
Medical/Dental
Sleeping Rooms
Shower
Laundry Room
Lounges
Offices
Conference Rooms
Classrooms
Medical/Dental
Reception
Wards (Patient)
Food Preparation
Dining/Lunch Rooms
Dishwashing
Storage Rooms
Gymnasium
Recreation
Locker Room
Toilets
Equipment Rooms (Elec/Mech)
Corridors & Stairs
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup Emergency Exit
Interior Lighting2. Number of Deficiencies = 3
Emergency /Exit Lighting3. Number of Deficiencies = 7
Page: 7 of 48
Building: 0001 - MAIN BUILDING
FIRE ALARM
Comments: All fire alarm systems on the Center are remotely monitored from the security area in Building 1. The Building 1 fire alarm system is based on Mirtone EST fire alarm control/annunciator panel, located in the security area on the first floor. Three other systems on Center are monitored by three remote annunciator panels also located in the security area of Building 1. These systems are based: one on Mirtone EST fire alarm panel, located in Building 7 and monitoring fire alarm devices in Buildings 2, 15 and 8; one - on Mirtone EST fire alarm panel, located in and monitored fire alarm devices in Building 10; and one Silent Knight fire alarm panel, located in Building 16 and monitoring fire alarm devices in Buildings 16, 17 and
18. System type smoke detectors and horns are provided in the fourth floor sleeping rooms of Building 1.
Beam detectors are utilized in the gymnasium of Building 1. All toilet rooms of Building 1 are provided with audio/visual devices.
Comments: Phone service/DEMARK point is located in the basement level phone room. The data distribution equipment is located in the first floor data closet (MC). The MC closet housed two Cisco 3900 series switches, one Cisco WAE 600 switch, one 4400 LAN wireless controller, one McAfee 1450 and one Blue Coat 9200 units, two Compaq , and one Dell server. The data equipment is provided by (3) Tripp Lite and two APC Pro 70 UPS units. One Dell Power Edge 2800 server and (4) Cisco 3560 PoE-24 switches are located in the medical area data closet. (4) security cameral utilized at the Center are monitored by the color monitor in the security area at the first floor. (3) cameras at the building: one at the SW corner, monitors the west gymnasium exits and entrance to the vocation area; one monitors the main building entrance (from Third Street), and one monitors the main lobby. Magnetic door alarms are provided at the back door exits. Metal detector (6500i by Garrett) is provided at the entrance.
Audible Alarm Central Annunciator Panel Duct Smoke Detector Flow Switch Flow/Tamper Switch Heat Detector Manual Pull Station Smoke Detector Tamper Switch Visual Alarm
Connected to Main System Magnetic Door/Alarm None TV with VCR
Telephone Security Public Address Television
Number of Deficiencies = 6
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
The spray polyurethane foam (SPF) roof is deteriorating, has holes and is leaking. The interior finishes in the Cafeteria are in worn condition. Light fixtures are deteriorated in multiple places.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas Yes YesYes
BUILDING UTILITY METERING
Structure: Good Exterior: Poor Interior: Fair Mechanical: Good Electrical: Fair
This building has been recommended for renovation in the Long Range Development Plan.
RENOVATION RECOMMENDATION
Type Location 120V Mech Rm & Kitchen
There is no plausible means by which harmful levels of CO could enter sleeping rooms. One battery operated carbon monoxide (CO) detector and one 120V hard wired with battery backup carbon monoxide (CO) detector are located in each of two following spaces: in the main kitchen and in the first floor mechanical room.
CARBON MONOXIDE DETECTION
Detection Required No
Number of Deficiencies = 0
Page: 8 of 48
Building: 0001 - MAIN BUILDING
IMPAIRMENT
Potentially Impaired
DOL Responded
DOL Determination
Potential Impaired Comments DOL Determination Discussion/Comments
BUILDING 2 - VOCATIONAL BUILDING
Page: 9 of 48
Building: 0002 - VOCATIONAL BUILDING
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Loadbearing Masonry Wood
The floor construction is concrete and wood frame.
Stucco
Wall Roof None Batt
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors Business 11,080 8,303 2 Owned 1930 Not Evaluated
Comments: The first floor of the building has four separate sections. Each section has an accessible entry. The largest section, located at the north of the building, has an exit which is not accessible. In the absence of an elevator, the second floor of the north section is not accessible.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
No
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Material
Asbestos: Yes
The remaining life expectancy is based on visual observation and condition of the roof during the January 2017 Facility Survey.
The remaining life expectancy is based on visual observation and condition of the roof during the January 2017 Facility Survey
Drainage Year Life
Remaining Type Area Served
Spray Polyurethane Foam
(SPF)
Spray Polyurethane Foam
(SPF)
Gutters and Downspouts
Interior Roof Drains
Gable
Flat
Original Building
Building Addition
Number of Deficiencies = 1
Comments:
Comments:
3. Roof
Entire Building
Page: 10 of 48
Building: 0002 - VOCATIONAL BUILDING
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
CMU Ceramic Tile Drywall Wood Paneling
Metal Unit - Metal Frame Wood Unit - Wood Frame
VERTICAL CIRCULATION
Concrete Stairs Wood Stairs Comments: There is one exterior concrete stair that leads to the upper level. There are two interior wood stairs that lead to the second floor.
Metal Overhead - Metal Frame Metal Unit - Metal Frame
Fixed - Aluminum Frame; Single Glazing; Fixed - Steel Frame; Single Glazing;
Sliding - Steel Frame; Single Glazing;
Acoustical Tile Exposed Structure Gypsum Board
Exterior Doors5. Number of Deficiencies = 1
Windows6.
Floors1. Asbestos: Yes Number of Deficiencies = 3
Interior Walls2.
3. Asbestos: Yes Number of Deficiencies = 1
Interior Doors4. Number of Deficiencies = 2
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
This building has 11 packaged heat pump units manufactured by Trane, Goettl, York, Ruud, and Tappan. Ten are 5 ton units. One is a 2 ton unit.
The warehouse area has electric unit heaters.
Comments:
Comments:
HVAC
Heat1.
Packaged Heat Pump (Air
Source)
Electric Resistance
Single Duct
Unit Heater
None
None
Electronic
Electric
Mechanical
Natural
None
None
Entire Building
Storage
Page: 11 of 48
Building: 0002 - VOCATIONAL BUILDING
Mechanical Restroom
Domestic hot water is provided by a 40 gallon electric water heater.Comments:
Cast-Iron None Cast-Iron
Electric Water Cooler Hose Bibb Lavatory Portable Bottled Water Cooler Urinal Water Closet (Tank)
None
None None ABC Type Fire Extinguisher
Ventilation Area Served
Galvanized Steel Galvanized Steel Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Packaged Heat Pump (Air
Source)
Single Duct None Electronic Mechanical None Entire Building
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
Exhaust Ventilation
This building has 11 packaged heat pump units manufactured by Trane, Goettl, York, Ruud, and Tappan. Ten are 5 ton units. One is a 2 ton unit.
Comments:
Ventilation2.
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3.
Fuel Distribution4.
FIRE PROTECTION
3. Air Conditioning
Page: 12 of 48
Building: 0002 - VOCATIONAL BUILDING
Comments: This building has two 120/240V 3-phase services. One service comes from a 75 and 50 kVA pole-mounted transformer bank across from Buchanan Street and terminates in a 600A main switchboard, located in the warehouse on the second floor. The other service comes from a 75 kVA and one 50 kVA pole-mounted transformer bank on Third Street and terminates in another 600A main switchboard, located in the electrical room on the first floor. The 600A switchboard on the second floor (through 200A MLO panel at the NW exterior building corner and the roof-mounted panel) sub-feeds Education Building 15 (1-phase service) and one 200A MLO panel in Building 7 (3-phase service). A utility meter is installed in each of the switchboards. The transformer bank on Third Street also serves Annex II-Multipurpose/HR Buildings 7 and Recreational Hall Building 8, each with a separated utility meter.
FIRE ALARM
Comments: The building fire alarm system components are connected to the fire alarm control panel (Mirtone EST) located in Building 7.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Heat Detector Manual Pull Station Smoke Detector Visual Alarm
Comments: Recorded footcandle levels include natural light contribution.
Comments: Combination emergency light exit sign fixtures are also provided.
Halogen High Intensity Discharge (HID) Light Emitting Diode (LED) Comments: Exterior building-mounted light fixtures are controlled by time clock and photocell. Structure-mounted
Light Emitting Diode (LED) light fixtures are provided at the court yard, are served and controlled from Building 2.
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
T8 - Fluorescent
Compact Fluorescent
T8 - Fluorescent
Storage/Warehouse-Active
Toilets
Classrooms
Offices
Classrooms
Storage Rooms
Equipment Rooms (Elec/Mech)
Toilets
Corridors & Stairs
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Main Switchboard 120/240V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
ELECTRICAL SERVICES Number of Deficiencies = 7
Exterior Lighting1.
Interior Lighting2. Number of Deficiencies = 1
Emergency /Exit Lighting3. Number of Deficiencies = 4
Page: 13 of 48
Building: 0002 - VOCATIONAL BUILDING
Comments: The building is connected to the center's LAN system for data communications. Wi-Fi is also provided.
The classrooms are equipped with TV-VCR and computer work stations. Magnetic door alarms are provided at the back door exit.
Connected to Main System None Connected to Main System TV with VCR
Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating
Comments:
X Good Fair Poor
The spray polyurethane foam (SPF) roof is deteriorating, has holes and is leaking. The interior finishes are in worn condition.
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas Yes N/AYes
BUILDING UTILITY METERING
Structure: Good Exterior: Poor Interior: Fair Mechanical: Good Electrical: Good
Type Location N/A N/A
There is no gas operated equipment in the building.
CARBON MONOXIDE DETECTION
Detection Required No
Number of Deficiencies = 0
IMPAIRMENT
Potentially Impaired
DOL Responded
BUILDING 7 - CTS OFFICES
Page: 14 of 48
Building: 0007 - CTS OFFICES
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Loadbearing Masonry Wood
The floor construction is concrete.
Brick Masonry Stucco
Wall Roof Batt Batt
Metal Unit - Metal Frame Storefront - Storefront Frame Wood Unit - Metal Frame
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors Bus/Assem 4,800 4,097 1 Owned 1978 Not Evaluated
Comments: The building has two sections. The Phoenix room located at the south does not have accessible restrooms. The restroom of the north section is also not accessible.
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
No
Yes
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Exterior Doors5. Number of Deficiencies = 1
Material Drainage Year Life
Remaining Type Area Served
Asphalt Shingles Surface Run-off 2001 4 Gable Entire Building
3. Roof
Entire Building
Page: 15 of 48
Building: 0007 - CTS OFFICES
INTERIOR FINISH
Carpet Ceramic Tile Vinyl Tile
CMU Ceramic Tile Drywall
Wood Unit - Wood Frame
Mechanical Restroom
Ventilation Area Served
VERTICAL CIRCULATION
Ramp Comments: A ramp leads to the north entrance.
Sliding - Aluminum Frame; Single Glazing;
Acoustical Tile Exposed Structure Gypsum Board
Exhaust Ventilation
Windows6.
Floors1. Number of Deficiencies = 1
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
There are two Ducane 5 ton units and one Ducane 4 ton unit, all mounted on the roof. The units were manufactured in 2002.
Comments:
HVAC
Heat1.
Packaged Heat Pump (Air
Source)
Single Duct None Electronic Mechanical None Entire Building
Ventilation2.
Page: 16 of 48
Building: 0007 - CTS OFFICES
Domestic hot water is provided by a 40 gallon electric water heater.Comments:
Cast-Iron None None
Electric Bottled Water Cooler Hose Bibb Lavatory Water Closet (Flush Valve) Water Closet (Tank)
None
Wet None ABC Type Fire Extinguisher
Copper Copper Electric None No
Hot Water Cold Water Water Heater Water Treatment HW Storage Tank
Grease InterceptorWaste / Vent Interior Storm
Packaged Heat Pump (Air
Source)
Single Duct None Electronic Mechanical None Entire Building
Sprinkler System Stand Pipe System Fire Suppression
PLUMBING
There are two Ducane 5 ton units and one Ducane 4 ton unit, all mounted on the roof. The units were manufactured in 2002.
Comments:
System Type
Air Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Water Distribution1.
Sanitary Distribution2.
Fixtures3. Number of Deficiencies = 1
Fuel Distribution4.
Page: 17 of 48
Building: 0007 - CTS OFFICES
Comments: The building is provided with two services. One 120/240V, 1-phase, 3 wire, overhead service is brought from a 75 kVA and a 50 kVA pole-mounted transformer bank on Third Street to a CT cabinet, utility meter, and two circuit breakers installed in the same enclosure on the southwest corner of the building and serving one 100A MLO and one 200A MLO panelboard in the south part of the building (conference/meeting room). This transformer bank also serves Vocational Building 2 and Recreational Hall Building 8, each with a separate utility meter. The second 120/240V, 3-phase, 4 wire service is provided from Building 2 to a 200A MLO panelboard serving north part of the building.
FIRE ALARM
Comments: The building fire alarm control/annunciator panel (FACP) is a Mirtone EST located in the pantry area of the building. The fire alarm system components of Buildings 2, 8 and 15 are connected to this FACP. The FACP is remotely monitored by the remote annunciator panel located security office in Building 1.
Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices
Audible Alarm Bell Control/Annunciator Panel Flow Switch Manual Pull Station Smoke Detector Tamper Switch Visual Alarm
Comments: Recorded footcandle levels include natural light contribution.
Comments: Combination emergency light exit sign fixtures are also provided.
Compact Fluorescent High Intensity Discharge (HID) Comments: Exterior building-mounted and surrounding area pole-mounted light fixtures are controlled by time clock and photocells.
T8 - Fluorescent
Compact Fluorescent
Compact Fluorescent
T8 - Fluorescent
CFL+T8 - Fluorescent
T8 - Fluorescent
Compact Fluorescent
Reception
Toilets
Storage Rooms
Offices
Conference Rooms
Equipment Rooms (Elec/Mech)
Toilets
Area Recommended Level
Recorded Level Light Type
Battery Backup Battery Backup
Main Disconnect Switch 120/240V, 1-Phase, 3 Wire Panelboard Receptacles, GFCI, Switches
Emergency Exit
ELECTRICAL SERVICES Number of Deficiencies = 3
Exterior Lighting1.
Interior Lighting2.
Emergency /Exit Lighting3.
Type Location N/A N/A
There is no gas operated equipment in the building.
CARBON MONOXIDE DETECTION
LIGHTING
Detection Required
Page: 18 of 48
Building: 0007 - CTS OFFICES
Comments: The building is connected to the center's LAN system for data communications. Wi-Fi is also provided.
A surveillance camera on the building northwest exterior corner is scanning the Center's front parking and main entrance from Buchanan Street. The camera is monitored from the security office in Building 1.
Connected to Main System Closed Circuit TV None TV with VCR Telephone Security Public Address Television
GENERAL BUILDING CONDITION
Rating X Good
Fair Poor
COMMUNICATION
The facility condition is not impacting the functional use of the facility.
The facility condition IS impacting the functional use of the facility.
The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.
Electric Water Gas Yes N/AYes
BUILDING UTILITY METERING
Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good
IMPAIRMENT
Potentially Impaired
DOL Responded
BUILDING 8 - RECREATION HALL/ADMINISTRATION
Page: 19 of 48
Building: 0008 - RECREATION HALL/ADMINISTRATION
BUILDING ENVELOPE
Foundation RoofBuilding
Concrete Loadbearing Masonry Wood
The floor construction is concrete.
Stucco
Wall Roof Batt Batt
AccessibilityFeature
GSF NSF Year Built Use Group Historic Ownership#Floors Assembly 10,050 7,639 1 Owned 1978 Not Evaluated
REAL ESTATE
Access to Building
Ramps
Entrance
2nd Egress
Visual Alarm
Corridor/Aisle
Rooms
Stairs
Elevator
Restrooms
Drinking Fountain
Telephone
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
N/A
Yes
No
N/A
ACCESSIBILITY
Structural Systems1.
Exterior Walls2.
Insulation4.
Material
The remaining life expectancy is based on visual observation and condition of the roof during the January 2017 Facility Survey
Drainage Year Life
Remaining Type Area Served
Asphalt Shingles
Rolled Asphalt
Rolled Asphalt
Surface Run-off
Surface Run-off
Surface Run-off
Gable
Flat
Shed
Original Building
East Building Addition
West Building Addition
Number of Deficiencies = 1
Comments:
3. Roof
Entire Building
Page: 20 of 48
Building: 0008 - RECREATION HALL/ADMINISTRATION
INTERIOR FINISH
Carpet Ceramic Tile Concrete Vinyl Tile
CMU Ceramic Tile Drywall
Wood Unit - Wood Frame
Mechanical Restroom
Ventilation Area Served
VERTICAL CIRCULATION
Ramp
Metal Unit - Metal Frame
Sliding - Aluminum Frame; Single Glazing;
Acoustical Tile Exposed Structure Gypsum Board
Exhaust Ventilation
Exterior Doors5. Number of Deficiencies = 1
Windows6.
Floors1.
Interior Walls2.
3.
Interior Doors4.
Heat Source
Heat Distribution
Piping System
Control System
Fresh Air Intake
Energy Conservation
Measure
Area Served
Heating and cooling are provided by four Arcoaire 5 ton…