16-Signage Removal Location Plans.pdf
PDF 4 MB Posted
- Solicitation number
- 26/0002
- Issued by
- Harris County, Texas
About this file
This is a signage removal and temporary replacement plan document for the MRI Scan Equipment Replacement and MRI Suite Renovation project at Smith Clinic for Harris Health in Texas, issued for construction on September 19, 2025. The document provides detailed location plans for signage removal across Level 1 and Level 4 of the facility, identifying specific room locations where existing room signage marked in red (conforming to old HHS Interior Signage Standards) must be removed. The awarded signage contractor is responsible for removing all existing room signage while coordinating with the general contractor and architect regarding industry-standard removal procedures. The contractor must also provide temporary signage at all locations within the scope prior to permanent signage installation. All existing PET/CT equipment postings and warning signage are to remain in place, as no new design postings are included in the current HHS Interior Signage Standards.
The temporary signage specifications require 1/16-inch thick Sintra board installed directly onto existing doors at adjacent permanent signage locations using low-tack tape for easy removal upon permanent signage installation. Temporary signage shall consist of full-size (100%) black and white digital prints directly printed onto the Sintra board. The signage contractor must conduct a site survey in coordination with the general contractor and architect prior to submitting final pricing to ensure complete understanding of the demolition scope. The overall project carries an estimated budget of $1,924,067 and encompasses signage location plans for multiple rooms across both levels of the facility.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISSUE FOR CONSTRUCTION
19 SEPT 2025
JKW
PET/CT Scan
JKW
SCP ACS SC MRI Scan 1.5T Replacement (MRI 1 & 3)
422089.05
EXISTING SIGNAGE
DEMO PLAN, LEVEL 1
EG-100A
EG-101.05
DEFINES AREA OF EXISTING SIGNAGE DEMO SCOPE
AND NEW HHS STANDARD SIGNAGE SCOPE
DEMO PLAN NOTES:
AWARDED SIGNAGE CONTRACTOR
RESPONSIBLE FOR THE REMOVAL
OF ALL EXISTING ROOM SIGNAGE AS
NOTED IN RED (OLD HHS INTERIOR
SIGNAGE STANDARD) AND
COORDINATING WITH GENERAL
CONTRACTOR FOR THE INDUSTRY
STANDARD OF REMOVAL OF ALL
ROOM SIGNAGE.
ALL EXISTING PET CT EQUIPMENT
POSTINGS AND WARNING SIGNAGE
TO REMAIN, AS NO NEW DESIGN
POSTINGS ARE INCLUDED IN THE
CURRENT HHS INTERIOR SIGNAGE
STANDARDS.
SIGNAGE CONTRACTOR TO
COORDINATE SITE SURVEY WITH
GENERAL CONTRACTOR AND
ARCHITECT, PRIOR TO
SUBMITTING FINAL PRICING TO
ENSURE FULL UNDERSTANDING
OF DEMO SCOPE.
JKW
PET/CT Scan
JKW
SCP ACS SC MRI Scan 1.5T Replacement (MRI 1 & 3)
422089.05
EXISTING SIGNAGE
DEMO PLAN, LEVEL 1 (ENLARGED)
EG-100B
EG-101.05
DEFINES AREA OF EXISTING SIGNAGE DEMO SCOPE
AND NEW HHS STANDARD SIGNAGE SCOPE
DEMO PLAN NOTES:
AWARDED SIGNAGE CONTRACTOR
RESPONSIBLE FOR THE REMOVAL
OF ALL EXISTING ROOM SIGNAGE AS
NOTED IN RED (OLD HHS INTERIOR
SIGNAGE STANDARD) AND
COORDINATING WITH GENERAL
CONTRACTOR FOR THE INDUSTRY
STANDARD OF REMOVAL OF ALL
ROOM SIGNAGE.
SIGNAGE CONTRACTOR TO
COORDINATE SITE SURVEY WITH
GENERAL CONTRACTOR AND
ARCHITECT, PRIOR TO
SUBMITTING FINAL PRICING TO
ENSURE FULL UNDERSTANDING
OF DEMO SCOPE.
ALL EXISTING PET CT EQUIPMENT
POSTINGS AND WARNING SIGNAGE
TO REMAIN, AS NO NEW DESIGN
POSTINGS ARE INCLUDED IN THE
CURRENT HHS INTERIOR SIGNAGE
STANDARDS.
JKW
PET/CT Scan
JKW
SCP ACS SC MRI Scan 1.5T Replacement (MRI 1 & 3)
422089.05
SIGNAGE LOCATION PLAN,
LEVEL 1
EG-101.05
1004 1008
REMOVAL & TEMP SIGNAGE NOTES:
AWARDED SIGNAGE CONTRACTOR
RESPONSIBLE FOR THE REMOVAL
OF ALL EXISTING ROOM SIGNAGE
AND COORDINATING WITH GENERAL
CONTRACTOR FOR THE INDUSTRY
STANDARD OF REMOVAL OF ALL
ROOM SIGNAGE.
1/16” THICK SINTRA® BOARD AND
INSTALLED DIRECTLY ONTO
EXISTING DOORS AT ADJACENT
PERMANENT SIGNAGE LOCATIONS
WITH LOW-TAC TAPE FOR EASY
REMOVAL AT THE TIME OF
PERMANENT SIGNAGE
INSTALLATION.
AWARDED SIGNAGE CONTRACTOR
RESPONSIBLE FOR PROVIDING
REPLACEMENT “TEMPORARY
SIGNAGE” AT ALL LOCATIONS WITHIN
THE SCOPE. TEMPORARY SIGNAGE
SHOULD BE ASSUMED TO BE: FULL
SIZE (100%) BLACK & WHITE DIGITAL
PRINTS, DIRECTLY PRINTED ONTO
JKW
PET/CT Scan
JKW
SCP ACS SC MRI Scan 1.5T Replacement (MRI 1 & 3)
422089.05
EXISTING SIGNAGE
DEMO PLAN, LEVEL 4
EG-400A
EG-401.05
DEFINES AREA OF EXISTING SIGNAGE DEMO SCOPE
AND NEW HHS STANDARD SIGNAGE SCOPE
DEMO PLAN NOTES:
AWARDED SIGNAGE CONTRACTOR
RESPONSIBLE FOR THE REMOVAL
OF ALL EXISTING ROOM SIGNAGE AS
NOTED IN RED (OLD HHS INTERIOR
SIGNAGE STANDARD) AND
COORDINATING WITH GENERAL
CONTRACTOR FOR THE INDUSTRY
STANDARD OF REMOVAL OF ALL
ROOM SIGNAGE.
ALL EXISTING PET CT EQUIPMENT
POSTINGS AND WARNING SIGNAGE
TO REMAIN, AS NO NEW DESIGN
POSTINGS ARE INCLUDED IN THE
CURRENT HHS INTERIOR SIGNAGE
STANDARDS.
SIGNAGE CONTRACTOR TO
COORDINATE SITE SURVEY WITH
GENERAL CONTRACTOR AND
ARCHITECT, PRIOR TO
SUBMITTING FINAL PRICING TO
ENSURE FULL UNDERSTANDING
OF DEMO SCOPE.
JKW
PET/CT Scan
JKW
SCP ACS SC MRI Scan 1.5T Replacement (MRI 1 & 3)
422089.05
EXISTING SIGNAGE
DEMO PLAN, LEVEL 4 (ENLARGED)
EG-400B
EG-401.05
DEFINES AREA OF EXISTING SIGNAGE DEMO SCOPE
AND NEW HHS STANDARD SIGNAGE SCOPE
DEMO PLAN NOTES:
AWARDED SIGNAGE CONTRACTOR
RESPONSIBLE FOR THE REMOVAL
OF ALL EXISTING ROOM SIGNAGE AS
NOTED IN RED (OLD HHS INTERIOR
SIGNAGE STANDARD) AND
COORDINATING WITH GENERAL
CONTRACTOR FOR THE INDUSTRY
STANDARD OF REMOVAL OF ALL
ROOM SIGNAGE.
SIGNAGE CONTRACTOR TO
COORDINATE SITE SURVEY WITH
GENERAL CONTRACTOR AND
ARCHITECT, PRIOR TO
SUBMITTING FINAL PRICING TO
ENSURE FULL UNDERSTANDING
OF DEMO SCOPE.
ALL EXISTING PET CT EQUIPMENT
POSTINGS AND WARNING SIGNAGE
TO REMAIN, AS NO NEW DESIGN
POSTINGS ARE INCLUDED IN THE
CURRENT HHS INTERIOR SIGNAGE
STANDARDS.
JKW
PET/CT Scan
JKW
SCP ACS SC MRI Scan 1.5T Replacement (MRI 1 & 3)
422089.05
SIGNAGE LOCATION PLAN,
LEVEL 4
EG-401.05
4003 4004
REMOVAL & TEMP SIGNAGE NOTES:
AWARDED SIGNAGE CONTRACTOR
RESPONSIBLE FOR THE REMOVAL
OF ALL EXISTING ROOM SIGNAGE
AND COORDINATING WITH GENERAL
CONTRACTOR FOR THE INDUSTRY
STANDARD OF REMOVAL OF ALL
ROOM SIGNAGE.
1/16” THICK SINTRA® BOARD AND
INSTALLED DIRECTLY ONTO
EXISTING DOORS AT ADJACENT
PERMANENT SIGNAGE LOCATIONS
WITH LOW-TAC TAPE FOR EASY
REMOVAL AT THE TIME OF
PERMANENT SIGNAGE
INSTALLATION.
AWARDED SIGNAGE CONTRACTOR
RESPONSIBLE FOR PROVIDING
REPLACEMENT “TEMPORARY
SIGNAGE” AT ALL LOCATIONS WITHIN
THE SCOPE. TEMPORARY SIGNAGE
SHOULD BE ASSUMED TO BE: FULL
SIZE (100%) BLACK & WHITE DIGITAL
PRINTS, DIRECTLY PRINTED ONTO
File details come from the government source that posted it. Updated .