FCI USP ADX grease interceptors 12000 Gal.pdf

PDF 59 KB Posted

Attached to
FCC FLORENCE QUARTERLY GREASE TRAP CLEANING
Solicitation number
15B40627Q00000001
Issued by

About this file

This document is a technical drawing and specification sheet for a grease interceptor system, presented as a detailed elevation view with accompanying capacity chart.

The drawing shows a secondary tank system with a total capacity of 1,608 cubic feet (12,000 gallons) designed according to strength specifications for H-5x4 bridge loading. The system features a 24-inch diameter access point at the top, a 12-inch minimum clean-out section, and a 90-degree bend configuration. The elevation view illustrates internal compartmentalization with dimensions marked in feet and inches, including a 12-inch section height, 2-inch clearance measurements, and a 9-inch offset component. A separate plan view diagram shows the spatial layout of the manhole, labeled as "typical of 4." The capacity chart breaks down the total 1,608 cubic feet (12,000 gallons) across compartments, with individual compartment capacities measured in gallons and feet: compartment volumes of 173, 144, 98, 43, and 13 cubic feet corresponding to the dual compartment tank design. The document is marked as "No Scale" and is drawn by or associated with "FCI," indicating this is a specifications document for manufacturing or procurement purposes rather than a federal solicitation document.