1502000 J Facility Investment.pdf
PDF 577 KB Posted
- Attached to
- Fire protection
- Solicitation number
- N4008524R2525
About this file
This document contains the Systems and Equipment Inventory for the fire protection system facilities at the Naval Support Activity and the Philadelphia Naval Business Center in Philadelphia, PA. It provides a detailed list of the various components of the fire detection and alarm system, as well as the wet pipe sprinkler system, at multiple buildings and wings on the installation. The inventory includes the location, device type, and quantity for fire alarm panels, batteries, pull stations, heat detectors, smoke detectors, alarm bells, and strobe lights across the different facilities. This information appears to be included as an attachment to a solicitation for Facility Investment Services for the fire protection systems at these sites.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 24R2525_Amendment0004.pdf | ||
| 24R2525_Amendment0003.pdf | ||
| 24R2525_Amendment0002.pdf | ||
| Site Visit Log and Inspection Reports.pdf | ||
| 24R2525_Amendment0001.pdf | ||
| Base Access Spreadsheet.xls | XLS spreadsheet | |
| 0200000 J Management and Administration.pdf | ||
| Section C - Annexes.pdf | ||
| J-0200000-06 ELINS KTR Fill In.xlsx | XLSX spreadsheet | |
| 24R2525_Fire Protection_RFP.pdf | ||
| Section F - Deliveries or Performance.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Section J – 1502000 Management and Administration
Attachment Number Attachment Title
J-1502000-01 SYSTEMS AND EQUIPMENT INVENTORY
J-1502000-02
J-1502000-03 HISTORICAL ROUTINE SERVICE CALL DATA
J-1502000-04 ASSET TAGGING GUIDANCE
J-1502000-05 DEFINITIONS AND ACRONYMS
TBD
ATTACHMENT J-01502000-01
EQUIPMENT LIST
See File J-1502000-01 SYSTEM Inventory.XLS
J-1502000-01
FIRE PROTECTION SYSTEM INVENTORY
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND RM 2221 NORTH END OF RM HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND RM 2222 AT EXIT HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND RM 2223 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND RM 2223 CENTER OF RM HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND RM 2223 WEST WALL HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND RM 2223 WEST WALL AND
CENTER OF RM
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND SOUTH EXIT HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND AT EXIT SOUTHEND STAIRWAY -
#6
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND NORTH EXIT-#4 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND SOUTH EXIT (HEATER RM)-#3 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND SOUTH EXIT-#2 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND SOUTH EXIT-#5 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND SOUTH EXIT-EXTERIOR-#1 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND STAIRWAY #6 SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND IN RM 2209 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND INSIDE RM 2207 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND RM 2209 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 COMMAND RM 2221 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 AT EXIT OF SO. END ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 COL. E-2 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 COL. K-2 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 IN HALLWAY ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 OUTSIDE 3107 RM (HALLWAY) ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 OUTSIDE RM 1129 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 OUTSIDE RM 2109 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1125 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1129 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH END OF WING ALARM BELL 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT ALARM PANEL (FCI) 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT BATTERIES 3
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT BATTERY BOX 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT DIGITIZE PANEL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 HALLWAY HEAT DETECTOR-COMBINED 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1109 HEAT DETECTOR-COMBINED 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1109 HEAT DETECTOR-COMBINED 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1111 - SECURITY RADIO RM HEAT DETECTOR-COMBINED 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1112 HEAT DETECTOR-COMBINED 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 117-B VIP GUEST ROOM HEAT DETECTOR-COMBINED 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 STAIRWAY BETWEEN 1ST AND
2ND DECK.
HEAT DETECTOR-COMBINED 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 ABOVE CEILING EAST SIDE HEAT DETECTOR-RATE OF 4 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 ABOVE CEILING WEST SIDE HEAT DETECTOR-RATE OF 4
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 ABOVE THE CEILING ON EAST
SIDE OF THE RM
HEAT DETECTOR-RATE OF 7
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 ABOVE THE CEILING ON THE
WEST SIDE OF THE RM
HEAT DETECTOR-RATE OF 7
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 AT S. END OF WING TO THE EAST
OF THE EXIT
HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 AT THE NORTH END OF THE
WING
HEAT DETECTOR-RATE OF 3
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 CENTER OF HALLWAY BELOW
CEILING
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 COL. G-7 HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 EAST OF COL. M-9 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 EAST OF COL. P-9 HEAT DETECTOR-RATE OF 1
SHEET 1 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 EAST OF EXIT AT SO. WING IN
CONFERENCE RM
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 IN CENTER OF HALLWAY BELOW
CEILING
HEAT DETECTOR-RATE OF 10
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 IN CENTER OF THE HALLWAY IN
WING
HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 IN RM 3105 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 IN RM 3107 (WOMEN REST RM) HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 IN ROOM 3102 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 INSIDE RM 2104 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 OUTSIDE RM 2105 HALLWAY HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 OUTSIDE RM 3105 HALLWAY HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 OUTSIDE ROOM 1125 HALLWAY HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1102 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1103 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1105 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1107 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1110 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1113 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1115 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1125 HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1129 ( MEN'S REST RM) HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 2104 HEAT DETECTOR-RATE OF 4 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 2105 HEAT DETECTOR-RATE OF 3
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 2107 (WOMEN REST RM) HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 3102 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 3105 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 3107 (WOMEN REST RM) HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT (CONFERENCE RM) HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT (OFFICE) HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT(OFFICES) HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 WEST OF COL. M-10 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 WEST OF COL. P-10 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 WEST OF EXIT HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 NORTH EXIT-#13 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 NORTH SIDE AT EXIT-#11 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 OUTSIDE RM 1117-#8 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1103 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT-#15 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT-#9 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH SIDE AT EXIT-#12 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH SIDE AT HANDICAP EXIT-
#19
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 WEST EXIT OF "O"CLUB AT
BATHROOMS-#14
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1120 SMOKE DETECTOR 3
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1121 SMOKE DETECTOR 8
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 117-B VIP GUEST RM SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH SIDE STAIRWAY SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 OUTSIDE 3107 RM (HALLWAY) STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 OUTSIDE RM 1129 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1125 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 1129 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 2104 STROBE 4
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 2107 (WOMEN REST RM) STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 RM 3107 STROBE 1
SHEET 2 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 1 SOUTH EXIT STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 AT FIRE PANEL ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 CENTER OF RM EAST SIDE ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 COL. K-10 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1205 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3205 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3206 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1204 HEATER RM ALARM HORN 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 SOUTH EXIT ALARM PANEL (FCI) 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 SOUTH EXIT BATTERIES 3
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 SOUTH EXIT BATTERY BOX 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 SOUTH EXIT DIGITIZE PANEL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 CENTER OF RM PUBLIC AFFAIRS HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 CUSTOMER OPERATION DEPT HEAT DETECTOR-RATE OF 3
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 IN PUBLIC AFFAIRS OFFICE HEAT DETECTOR-RATE OF 3
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 INSIDE RM 1202 PUBLIC AFFAIRS HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 INSIDE RM 1204 HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 OUT SIDE OF RM1207 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 OUTSIDE HEATER RM 1204 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 OUTSIDE RM 1200 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 OUTSIDE RM 1201 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 OUTSIDE RM 1204 HALLWAY HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 OUTSIDE RM 2200 HALLWAY HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 OUTSIDE RM 3200 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 OUTSIDE RM 3205 HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1202 PUBLIC AFFAIRS LAB. HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1203 AT EXIT HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1203 CENTER OF RM HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1203 NORTH END OF RM HEAT DETECTOR-RATE OF 4 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1205 20' FROM NORTH WALL HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1205 AT EXIT HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1205 CENTER OF RM HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1205 WEST END OF RM HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 2200 OUTSIDE HALLWAY HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 2201 (MEN'S REST RM) HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 2203 HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3201 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3201 IN CENTER OF ROOM HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3203 HEAT DETECTOR-RATE OF 4 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3203 (IN CONFERENCE RM) HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3205 HEAT DETECTOR-RATE OF 3 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3206 HEAT DETECTOR-RATE OF 4 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3209 HEAT DETECTOR-RATE OF 4 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 AT NORTH END- #7-BY EXIT PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 OUTSIDE RM 3200 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1203 SM. ROOM EAST OF EXIT PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 SOUTH EXIT-#12 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 AT FIRE PANEL STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 COL. K-10 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1205 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 1206 WEST WALL STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 2201 (MEN'S RM) STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3203 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3205 STROBE 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 2 RM 3206 STROBE 1
SHEET 3 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 AT SOUTH END OF WING AT EXIT ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 AT SOUTH EXIT ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST END OF RM 50' FROM
NORTH EXIT
ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF RM 50' FROM
NORTH EXIT
ALARM BELL 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 OUTSIDE OF RM 1207 (MAIL RM) ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WEST SIDE OF RM 10' AWAY
FROM SOUTH EXIT
ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 SOUTH EXIT ALARM PANEL (FCI) 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 SOUTH EXIT BATTERIES 5
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 SOUTH EXIT BATTERY BOX 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 SOUTH EXIT DIGITIZE PANEL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 BY SOUTH EXIT HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 CENTER OF HALLWAY HEAT DETECTOR-RATE OF 5
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF EXIT ON SOUTH
WING
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF RM AT EXIT HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF RM 12' FROM A/C
#16 IN WINDOW
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF RM 16' FROM
HALLWAY AT EXIT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF RM 20' FROM
NORTH EXIT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF RM 30' FROM
SOUTH EXIT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF RM 50' OF NORTH
EXIT
HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF RM 8' FROM
SOUTH EXIT
HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF ROOM 10' OF HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EASTSIDE OF RM CENTER 20' HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 MAIL RM, MAIN HALL WAY
OUTSIDE
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 MEN'S RM-3213 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 OUTSIDE RM 1307 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 OUTSIDE RM 3213 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM 1303 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM 1307 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM 1308 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM 2229 HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM 2302 (WOMEN) HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM 2305 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 SOUTH EXIT (OFFICES) HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 SOUTH EXIT(OFFICES) HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 STAIRWAY #6 HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WEST SIDE OF RM 10' FROM
NORTH EXIT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WEST SIDE OF RM 16' FROM
HALLWAY
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WEST SIDE OF RM 20' FROM
SOUTH EXIT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WEST SIDE OF RM 30' DOWN
HALLWAY 20' IN FROM
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WEST SIDE OF RM 30' FROM EXIT
ON SOUTH WING
HEAT DETECTOR-RATE OF 1
SHEET 4 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WEST SIDE OF RM 30' FROM
HALLWAY IN WING NORTH
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WEST SIDE OF RM 50' FROM
NORTH EXIT
HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WESTSIDE IN OFFICE NORTHEND HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WESTSIDE OF RM 20' FROM
SOUTH EXIT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WESTSIDE OF RM 50' FROM
SOUTH EXIT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WOMAN'S RM 3303 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 SOUTH EXIT-#20 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 SOUTH EXIT-#21 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 SOUTH EXIT-#22 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 SOUTH STAIRWAY EXIT SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 AT SOUTH END OF WING AT EXIT STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 AT SOUTH EXIT STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST END OF RM 50' FROM
NORTH EXIT
STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF RM 50' AWAY
FROM NORTH EXIT
STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 EAST SIDE OF RM 50' FROM
NORTH EXIT
STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 MEN'S RM STROBE 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM 1207 (MAILROOM) STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM 1303 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM 3306 IN HALLWAY STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM 3306 IN SM. OFFICE STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 RM1307 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WEST SIDE OF RM 10' AWAY
FROM SOUTH EXIT
STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 3 WOMAN'S RM STROBE 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 CENTER OF HALLWAY 30' FROM
NORTH EXIT
ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 COL. J-24 ALARM BELL 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 COL. P-25 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 CONFERENCE ROOM ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 OUTSIDE RM 3407 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 1401 NORTH SIDE CENTER OF
RM
ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 3401 ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SOUTH END AT EXIT ALARM BELL 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SOUTH EXIT ALARM PANEL (FCI) 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SOUTH EXIT BATTERIES 3
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SOUTH EXIT BATTERY BOX 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SOUTH EXIT DIGITIZE PANEL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 3401QQ HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 CENTER OF HALLWAY HEAT DETECTOR-RATE OF 6 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 COL. K-24 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 COL. K-25 HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 COL. N- 25 HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 EAST END AT NORTH EXIT RM
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 HALLWAY OUTSIDE RM 1403 HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 JOHN BAKERS OFFICE SO. EAST
END OF OFFICE
HEAT DETECTOR-RATE OF 2
SHEET 5 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 MECH. RM WEST END OF OFFICE HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 OUTSIDE 3413 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 OUTSIDE RM 3413 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 1313 HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 1401 WEST END OF ROOM HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 3401 HEAT DETECTOR-RATE OF 9 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 3403 HEAT DETECTOR-RATE OF 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 3407 HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SO. EAST END OF OFFICE, JOHN
BAKER OFFICE SO. EAST
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 WEST END AT NORTH EXIT RM
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 FREIGHT ELEVATOR LOBBY-#17 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 3401 PULL STATION 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SOUTH END AT EXIT-#23 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SOUTH END AT EXIT-#25 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SOUTH EXIT-#24 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 C ENTER OF RM SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 CENTER OF RM SMOKE DETECTOR 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 CONFERENCE RM SMOKE DETECTOR 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 EAST END OF RM 10' FROM SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 EAST END OF RM 30' FROM SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 EASTSIDE OF RM SOUTH END SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 HALLWAY OUTSIDE RM 2400 SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 IN OFFICE EAST END SMOKE DETECTOR 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 IN OFFICES WEST END SMOKE DETECTOR 4
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 2400 SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 WEST END OF RM 10' FROM
NORTH EXIT
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 WEST END OF RM 30' FROM
NORTH EXIT
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 AT COL. J-24 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 CENTER OF HALLWAY 30' FROM
NORTH EXIT
STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 COL. J-24 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 COL. P-25 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 CONFERENCE ROOM STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 OUTSIDE RM 3407 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 1401 NORTHSIDE CENTER OF
RM
STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 RM 3401 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SOUTH END AT EXIT STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 SOUTH EXIT STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 STROBE IN MEN RM 3403 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 4 WOMEN RM 3407 STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 AT CENTER OF RM EAST SIDE ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 AT NORTH EXIT ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 AT SOUTH END OF WING AT EXIT ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST SIDE OF RM 10' AWAY
FROM SOUTH EXIT
ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST SIDE OF RM 25' FROM
NORTH EXIT 5' FROM EXIT
ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EASTSIDE OF RM AT SOUTH EXIT
IN OFFICE
ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 SOUTH EXIT ALARM PANEL (FCI) 1
SHEET 6 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 SOUTH EXIT BATTERIES 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 SOUTH EXIT DIGITIZE PANEL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 CENTER HALLWAY HEAT DETECTOR-RATE OF 4
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 CENTER HALLWAY 10' FROM
NORTH EXIT
HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 CENTER HALLWAY 20' FROM
NORTH EXIT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST END 50' AWAY FROM
SOUTH EXIT (OFF CENTER
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST END AT SOUTH EXIT HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST SIDE OF RM 10' FROM HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST SIDE OF RM 10' FROM HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST SIDE OF RM 30' FROM
NORTH EXIT AT EXIT LIGHT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST SIDE OF RM 30' FROM
SOUTH EXIT ACROSS FROM
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST SIDE OFF OF HALLWAY 10'
FROM NORTH EXIT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EASTSIDE OF RM AT SOUTH EXIT
IN OFFICE
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 IN PAYROLL OFFICE HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 IN PAYROLL ROOM HEAT DETECTOR-RATE OF 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 RM 2105 OFFICE OF COUNSEL HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 RM ENGINEERING LIBRARY & CD HEAT DETECTOR-RATE OF 4
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 RMENGINEERING LIBRARY & CD HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 SOUTH EXIT STAIRWAY HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 WEST END 50' AWAY FROM
SOUTH EXIT (OFF OF CENTER
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 WEST END AT SOUTH EXIT HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 WEST SIDE OF RM 10' FROM
SOUTH EXIT IN DEPUTY
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 WEST SIDE OF RM AT SOUTH
EXIT IN OFFICE
HEAT DETECTOR-RATE OF 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 WEST SIDE OF RM DEPUTY
DIRECTOR
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 WEST SIDE OF RM OUTSIDE
DIRECTOR OFFICE
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 WEST SIDE OFF OF HALLWAY 10'
FROM NORTH EXIT
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 WING 5, IN CONFERENCE RM HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 AT SOUTH END OF WING-#32 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 AT SOUTH EXIT-#30 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 CENTER OF HALLWAY PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST SIDE OF RM 20' FROM
NORTH EXIT NORTH OF EXIT
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 NORTH END AT EXIT-#26 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 NORTHEAST EXIT-#31 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 NORTHEAST EXIT-#33 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 RM ENGINEERING LIBRARY & CD PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 SOUTH END AT EXIT-#28 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 SOUTH END AT EXIT-EXTERIOR-
#27
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 SOUTH EXIT BY MECH.RM.1410-
#10
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 AT CENTER OF RM EAST SIDE STROBE 1
SHEET 7 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 AT NORTH END OF WING AT EXIT STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 AT NORTH EXIT STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 AT SOUTH END OF WING AT EXIT STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 AT SOUTH EXIT STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST SIDE OF RM 10' AWAY
FROM SOUTH EXIT
STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 5 EAST SIDE OF RM 25' FROM
NORTH EXIT 5' FROM EXIT
STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 AT NORTHEAST EXIT ALARM BELL/STROBE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 AT WEST EXIT ALARM BELL/STROBE 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 EAST END OF WING NORTHEAST ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 NORTH SIDE . 20' FROM WEST ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 SOUTH SIDE 40' FROM EAST EXIT ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 WEST FIRE TOWER AT FIRE ALARM HORN AND STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 SOUTH EXIT ALARM PANEL (FCI) 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 SOUTH EXIT BATTERIES 4
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 SOUTH EXIT DIGITIZE PANEL 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 60' FROM WEST EXIT NORTH SIDE HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 75' FROM WEST EXIT NORTH SIDE HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 CENTER HALLWAY HEAT DETECTOR-RATE OF 4
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 CENTER OF HALLWAY HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 EAST END OF WING IN
CONFERENCE RM
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 EAST END OF WING NORTHSIDE
OF RM 12' FROM CENTER
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 RM 1600 CONFERENCE RM HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 WEST END OF WING
SOUTHWEST SECTION OF WING
(1)
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 WEST END OF WING NORTH SIDE
OF RM IN OFFICE (3)
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 WEST END OF WING
NORTHWEST SIDE OF WING
HEAT DETECTOR-RATE OF 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 WEST EXIT-#34 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 WEST EXIT-#35 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 WEST EXIT-#36 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 WEST EXIT FIRE TOWER SMOKE DETECTOR 2 REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 6 IN WEST END FIRE TOWER STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 OUTSIDE SOUTH EXIT GOING
INTO FIRE TOWER
ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 NORTH EXIT ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 NORTH EXIT GOING INTO WING 6 ALARM BELL/STROBE 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 SOUTH EXIT ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 SOUTH EXIT GOING INTO FIRE
TOWER
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 OUTSIDE SOUTH EXIT IN CEILING ALARM HORN 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 SOUTH EXIT ALARM PANEL (FCI) 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 SOUTH EXIT BATTERIES 4
SHEET 8 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 SOUTH EXIT BATTERY BOX 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 NORTH EXIT GOING INTO WING 6- #39
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 NORTH EXIT GOING INTO WING 6- #41
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 NORTH EXIT-#37 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 SOUTH EXIT OUTSIDE FIRE
TOWER-#42
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 SOUTH EXIT-#38 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 1 WING 7 SOUTH EXIT-#40 PULL STATION 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 1 NORTH FLOW SWITCH 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 2 NORTH FLOW SWITCH 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 2 SOUTH FLOW SWITCH 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 3 SOUTH FLOW SWITCH 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 4 NORTH FLOW SWITCH 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 4 SOUTH FLOW SWITCH 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 5 SOUTH FLOW SWITCH 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 7 SOUTH FLOW SWITCH 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 3 NORTH FLOW SWITCH 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 5 NORTH FLOW SWITCH 1
REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 6 SOUTH FLOW SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 1 SOUTH FLOW SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 5 SOUTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 2 NORTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 3 SOUTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 6 SOUTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 7 SOUTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING2 SOUTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 1 SOUTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 3 NORTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 4 NORTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 4 SOUTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 5 NORTH TAMPER SWITCH 1 REGION-N WET PIPE SPRINKLER SYSTEM NSA PHILA 1 FIRE RISER WING 1 NORTH TAMPER SWITCH 1
DLA-TS CARBON DIOXIDE NSA PHILA 2 B MECHANICAL ROOM 36 2 POLE PRESS. OPER. SWITCHES
(KIDDE P/N B4485)
DLA-TS CARBON DIOXIDE NSA PHILA 2 B MECHANICAL ROOM 36 3 POLE PRESS. OPER. SWITCHES
(KIDDE P/N 3PDT)
DLA-TS CARBON DIOXIDE NSA PHILA 2 B OFFICE SPACE BY ENTRANCE ABORT BUTTON 1
DLA-TS CO2/DRY CHEMICAL NSA PHILA 2 B MECHANICAL ROOM 36 AUTO XFER SWITCH 1 PH 250V/40A
(ZENITH MODEL OT4BC-2EG)
DLA-TS CARBON DIOXIDE NSA PHILA 2 B MECHANICAL ROOM 36 CO2 CYLINDERS (KIDDE) 32
DLA-TS DRY CHEMICAL NSA PHILA 2 B MECHANICAL ROOM 36 DRY CHEM CYLS. (CHEMETRON SER
#F1745757Y)
DLA-TS DRY CHEMICAL NSA PHILA 2 B MECHANICAL ROOM 36 PRESSURE SWITCH 1
DLA-TS CARBON DIOXIDE NSA PHILA 2 B COMP. RM. & OFFICE SPACE
(LOC. ON COLUMNS)
SUPPLY PULL PINS (KIDDE P/N 875572) 6 CHEMETRON MODEL # 10170089
DLA-TS DRY CHEMICAL NSA PHILA 2 B COMPUTER ROOM BY VAULT AREATOGGLE SWITCH (CHEMTRONICS) 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 40' FROM NORTH
EXIT(COMPUTER RM-SPAR
WARS)
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A BY NORTH EXIT-COMPUTER
REPAIR RM-SPAR WARS
ALARM BELL/STROBE 1
SHEET 9 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A CENTER OF CLASSROOM-SPAR
WARS
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COL.B-45-SALTS COMPUTER
ROOM
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COMPUTER RM-22'FROM WEST
EXIT-SPAR WARS
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A EAST EXIT-SPAR WARS ALARM BELL/STROBE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A HALLWAY-OUTSIDE OF SALTS ALARM BELL/STROBE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A NORTH EXIT-SPAR WARS ALARM BELL/STROBE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SOUTH EXIT-SPAR WARS ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 22' FROM WEST EXIT ON
WALL(COMPUTER RM IN SPAR
ALARM HORN AND STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A CENTER OF COMPUTER RM
(SPAR WARS)
ALARM HORN AND STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A NORTH WALL OUTSIDE SALTS ALARM HORN AND STROBE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SALTS HALLWAY ALARM HORN AND STROBE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SOUTH EXIT-SALTS ALARM HORN AND STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SOUTH WALL(30' FROM SOUTH
EXIT)
ALARM HORN AND STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SALTS COMPUTER ROOM
HALLWAY
ALARM PANEL (FIRE LITE SENSISCAN
1000)
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SOUTH SIDE OF CO2 ROOM ALARM PANEL (FIRE LITE SENSISCAN 1000)
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SALTS COMPUTER ROOM
HALLWAY
BATTERIES 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SOUTH SIDE OF CO2 ROOM BATTERIES 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SALTS COMPUTER ROOM
HALLWAY
BATTERY BOX 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SALTS HALLWAY EAST END CO2 PULL STATION (RESERVE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SALTS HALLWAY WEST END CO2 PULL STATION (RESERVE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SALTS HALLWAY EAST END MAIN CO2 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A EAST EXIT-SPAR WARS-#44 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A HALLWAY EAST EXIT-SALTS-#46 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A HALLWAY WEST EXIT-SALTS-#47 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A NORTH EXIT-BY SHREDDER-#45 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A NORTH EXIT-SPAR WARS-#48 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SOUTH EXIT-SALTS-#253 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SOUTH EXIT-SALTS-#49 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A SOUTH EXIT-SPAR WARS-#50 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A UPS ROOM-EAST EXIT-#51 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A UPS ROOM-WEST EXIT-#52 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 10' FROM EAST WALL(COMPUTER
REPAIR RM)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 10' FROM NORTH WALL(CENTER
OF SALTS OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 10' FROM NORTH WALL(N.E,C OF
SALTS OFFICE))
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 10' FROM NORTH WALL(N.W.C.
OF SALTS OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 10' INSIDE CLASSRM SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 12' FROM EAST WALL(CENTER OF
RM)-SALTS OFFICE
SMOKE DETECTOR 1
SHEET 10 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 12' FROM EAST WALL(NORTH
SIDE)-SALTS OFFICE
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 12' FROM EAST WALL(SOUTH
SIDE)-SALTS OFFICE
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 15' FROM WEST EXIT(COMPUTER
RM IN SPAR WARS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 30' FROM EAST WALL(COMPUTER
REPAIR RM)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 30' FROM NORTH WALL (CENTER
OF SALTS OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 30' FROM NORTH WALL (N.E.C.
OF SALTS OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 30' FROM NORTH WALL(N.W.C.
OF SALTS OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A 50' FROM EAST WALL(COMPUTER
REPAIR RM)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A CENTER OF CLASSRM-30'FROM
NORTH WALL
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A CENTER OF CONFERENCE RM SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COMPUTER RM 12'FROM SOUTH
WALL(CENTER OF SALTS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COMPUTER RM 12'FROM SOUTH
WALL(S.E.C OF SALTS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COMPUTER RM 30' FROM SOUTH
WALL(S.E.C. OF SALTS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COMPUTER RM 50' FROM SOUTH
WALL(S.E.C. OF SALTS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COMPUTER RM12'FROM SOUTH
WALL (S.W.C. OF SALTS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COMPUTER RM30' FROM SOUTH
WALL(CENTER OF SALTS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COMPUTER RM30' FROM SOUTH
WALL(S.W.C.OF SALTS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COMPUTER RM50' FROM SOUTH
WALL(CENTER OF SALTS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A COMPUTER RM50' FROM SOUTH
WALL(S.W.C. OF SALTS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A K 49 SMOKE DETECTOR-UNDER 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 A K 49 SMOKE DETECTOR-UNDER 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B CO2 RM SOUTHEAST SIDE OF
BLDG.
ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B OUTSIDE FISC BUSINESS OFFICE ALARM BELL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B 30' FROM NORTH WALL(CENTER
OF CONTRACT OFFICE)
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B 30' FROM NORTH WALL(S.E.C. OF
CONTRACT OFFICE
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B 30' FROM NORTH WALL(S.W.C.
OF CONTRACT OFFICE
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B ABOVE SOUTH EXIT IN REAR
OFFICE
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B CENTER OF NORTH WALL(Z.T.
COMPUTER RM)
ALARM BELL/STROBE 1
SHEET 11 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B CENTER OF SOUTH WALL(Z.T.
COMPUTER RM)
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B CENTER OF WEST WALL(Z.T.
COMPUTER RM)
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B CENTER OF WEST
WALL(Z.T.COMPUTER RM)
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.H-33(Z.T. COMPUTER RM) ALARM BELL/STROBE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.H-36(Z.T. COMPUTER RM) ALARM BELL/STROBE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.H-38(Z.T.COMPUTER RM) ALARM BELL/STROBE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.H-40(Z.T.COMPUTER RM) ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B EASTWALL 10' FROM EAST
EXIT(Z.T. OFFICE)
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B HALLWAY 30'WEST OF EAST
WALL
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B HALLWAY OUTSIDE OF
PROJECTION RM
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B HALLWAY REAR OFFICE SUPPLY
RM
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B IN PROJECTION RM ALARM BELL/STROBE 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B KITCHEN AREA (SPARS WARS) ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B MEN'S RM ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B NEAR SOUTH EXIT(MAIL ROOM) ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B NORTH EXIT ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B NORTHSIDE OF SPAR WARS
OFFICE
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B OUTSIDE CONTRACT OFFICE
HALLWAY
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B OUTSIDE OFDISTRIBUTION
OFFICE
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SOUTHSIDE OF SPAR WARS
OFFICE
ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B WOMAN'S RM ALARM BELL/STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B AT NORTH EXIT ALARM HORN AND STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B ON EAST WALL 14'FROM EAST
EXIT
ALARM HORN AND STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SOUTHSIDE OF SPAR WARS
OFFICE
ALARM HORN AND STROBE 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B DSCP COMPUTER ROOM VAULT ALARM PANEL (CHEMOTRONICS 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B DSCP COMPUTER ROOM ALARM PANEL (FCI) 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B NORTH ENTRANCE FOR SECTION
A & B
ALARM PANEL (FCI) 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SALTS COMPUTER RM WEST
WALL
ANNUNCIATOR PANEL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B DSCP COMPUTER ROOM BATTERIES 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B DSCP COMPUTER ROOM VAULT BATTERIES 2
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B NORTH ENTRANCE FOR SECTION
A & B
BATTERIES 6
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B NORTH ENTRANCE FOR SECTION
A & B
DIGITIZE PANEL 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SALTS HALLWAY WEST END MAIN CO2 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B NORTHSIDE LOADING DOCK( CO
2 RM)-#53
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B NORTH EXIT-#55 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B NORTH EXIT(FISC)-#56 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B NORTH EXIT_BY OLD MAIL RM.#75 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SOUTH EXIT-BY FISC BUSINESS
OFFICE-#58
PULL STATION 1
SHEET 12 OF 117
CLIENT SYSTEM SITE BLDG SECTION LOCATION DEVICE TYPE QTY COMMENTS
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SOUTH EXIT-BY FISC MAIL ROOM-
#59
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SOUTHSIDE EXTERIOR-#60 PULL STATION 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SOUTHSIDE-A/C ROOM-#71 PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SOUTHSIDE-MECH.RM.(GENSIS)-
#249
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SPAR WARS-NORTH EXIT IN
OFFICE-#43
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B SPAR WARS-NORTH EXIT IN
VESTIBULE-#89
PULL STATION 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B 10' FROM EAST WALL(N.E.C, OF
Z.T. OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B 10' FROM EAST WALL(S.E.C. OF
Z.T. OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B 10' FROM WEST WALL(S.W.C. OF
Z.T. OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B 10'FROM WEST WALL(N.W.C. OF
Z.T. OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B 8' FROM SOUTH EXIT (HALLWAY
OF FISC OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B ABOVE SOUTH EXIT(FISC
BUSINESS OFFICE)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.G-31(Z.T. COMPUTER RM) SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.G-32(Z.T. COMPUTER RM) SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.G-34(Z.T. COMPUTER RM) SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.G-35(Z.T. COMPUTER RM) SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.G-37(Z.T. COMPUTER RM) SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.H-31(Z,T, COMPUTER RM SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.H-32(Z.T. COMPUTER RM) SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.H-34(Z.T.COMPUTER RM) SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.H-35(Z.T, COMPUTER RM) SMOKE DETECTOR 1 REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B COL.H-37(Z.T. COMPUTER RM) SMOKE DETECTOR 1
REGION-N FIRE DETETCTION & ALARM NSA PHILA 2 B CONTRACT HALLWAY(12'EAST OF
CENTER DOORS)
SMOKE DETECTOR 1
REGION-N FIRE DETETCTION…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .