15. AF 66-SUB Register - DSN B2400 Server Room.xlsx
XLSX spreadsheet 57 KB Posted
- Attached to
- B2400 Server Room P209 Federal contract opportunity
- Solicitation number
- FA441822R0016
About this file
This submittal register outlines the required submissions for a firm-fixed price construction contract to complete project DKGV 11-10361/NNPTC B2400 Server Room P209 at Joint Base Charleston Naval Weapons Station. The contractor shall provide all labor, materials, equipment and supervision to construct a new server room in existing room P209 in building B2400, including moving the existing server room from D216 to P209, installing new racks, cable management, UPS, in-row cooling, and fiber runs from D216 to P209. A new HVAC system separate from the building HVAC will also be provided for the server room. The contractor must attend a pre-proposal site visit on August 3, 2022 and the performance period is 360 days. The solicitation is a 100% HUBZone small business set-aside issued by the 628th Contracting Squadron with anticipated award by the Department of the Air Force. The submittal register outlines over 100 required submissions at various stages of the project for items including qualifications, schedules, plans, reports, certifications, inspections and closeout documents.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment 04.pdf | ||
| Revised B2400 Server Room Questions.pdf | ||
| B2400 Server Room Questions.pdf | ||
| Solicitation Amendment 03.pdf | ||
| B2400 Server Room Sign-in.jpg | JPG image | |
| Davis Bacon Act WD SC20220022 Berkeley County Mod 2 22JUL22.pdf | ||
| Solicitation Amendment 02.pdf | ||
| Solicitation Amendment 01.pdf | ||
| 17b. Server Room Final Specifications.pdf | ||
| Davis Bacon Act WD SC20220022 Berkeley County Mod 1 25FEB22.pdf | ||
| 17. B2400 Server Room Final Drawings.pdf | ||
| Solicitation - FA441822R0016.pdf | ||
| 17a. Server Room Final 01 General Requirements.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Submittal Register
| SUBMITTAL REGISTER | CONTRACT NO. | |||||||
| DKGV1110361 | ||||||||
| TITLE AND LOCATION | CONTRACTOR | |||||||
| DSN B2400 Server Room, JBC | ||||||||
| ACTIVITY NO | TRANSMITTAL NO | SPEC SECT | DESCRIPTION OF ITEM SUBMITTED | PARAGRAPH # | CLASSIFICATION | |||
| GOVT OR A/E REVIEW | CONTRACTOR | |||||||
| SCHEDULE DATES | CONTRACTOR | |||||||
| ACTION | APPROVING AUTHORITY | RETURNED TO CONTR/ |
| DATE RCD FRM APPV AUTH | REMARKS | ||||||
| SUBMIT | APPROVAL NEEDED BY | MATERIAL NEEDED BY | ACTION CODE | DATE OF ACTION | DATE FWD TO APPR AUTH/ |
| DATE RCD ROM CONTR | DATE FWD TO OTHER REVIEWER | DATE RCD FROM OTH REVIEWER | ACTION CODE | DATE OF ACTION | ||||||||||||||
| (a) | (b) | (c) | (d) | (e) | (f) | (g) | (h) | (i) | (j) | (k) | (l) | (m) | (n) | (o) | (p) | (q) | (r) | |
| 01 11 00 | SD-01 - Outage Requests | 1.6.2 | G | |||||||||||||||
| 01 11 00 | SD-01 - Road Closure Requests | 1.6.2 | G | |||||||||||||||
| 01 11 00 | SD-01 - Work Clearance | 1.6 | G | |||||||||||||||
| 01 14 00 | SD-01 - List of Contact Personnel | 1.2.1.1 | G | |||||||||||||||
| 01 30 00 | SD-01 - Resume for the proposed Superintendent | 1.5.2 | G | |||||||||||||||
| 01 30 00 | SD-04 - Color Boards | 1.2 | G | |||||||||||||||
| 01 32 16.00 20 | SD-01 - Qualifications | 1.2 | G | |||||||||||||||
| 01 32 16.00 20 | SD-01 - Project Schedule | 1.3 | G | |||||||||||||||
| 01 32 16.00 20 | SD-01 - Initial Contract Progress Report (AF IMT 3065) | 1.4.1 | G | |||||||||||||||
| 01 32 16.00 20 | SD-01 - Initial Contract Progress Schedule (AF IMT 3064) | 1.4.2 | G | |||||||||||||||
| 01 32 16.00 20 | SD-07 - Project Schedule Updates | 1.3.3 | G | |||||||||||||||
| 01 32 16.00 20 | SD-07 - Monthly Contract Progress Reports (AF IMT 3065) | 1.4.1 | G | |||||||||||||||
| 01 32 16.00 20 | SD-07 - Monthly Contract Progress Schedules (AF IMT 3064) | 1.4.2 | G | |||||||||||||||
| 01 33 00 | SD-01 - Submittal Register | 1.7 | G | |||||||||||||||
| 01 35 26 | SD-01 - Accident Prevention Plan (APP) | 1.6 | G | |||||||||||||||
| 01 35 26 | SD-01 - Activity Hazard Analysis (AHA) | 1.7 | G | |||||||||||||||
| 01 35 26 | SD-01 - Critical Lift Plan | 1.6.1.1 | G | |||||||||||||||
| 01 35 26 | SD-01 - Crane Operators | 1.5.1.3 | G | |||||||||||||||
| 01 35 26 | SD-06 - Notifications and Reports | 1.11 | ||||||||||||||||
| 01 35 26 | SD-06 - Accident Reports | 1.11.2 | G | |||||||||||||||
| 01 35 26 | SD-06 - Crane Reports | 1.11.3 | ||||||||||||||||
| 01 35 26 | SD-07 - Confined Space Entry Permit | 1.8.1 | ||||||||||||||||
| 01 35 26 | SD-07 - Hot Work Permit | 1.8.1 | ||||||||||||||||
| 01 35 26 | SD-07 - License Certificates | 1.13 | ||||||||||||||||
| 01 45 00 | SD-01 - QC Plan | 1.6 | G | |||||||||||||||
| 01 50 00 | SD-01 - Construction Site Plan | 1.3 | G | |||||||||||||||
| 01 50 00 | SD-01 - Traffic Control Plan | 3.4.1 | G | |||||||||||||||
| 01 50 00 | SD-03 - Backflow Preventers | 1.4 | ||||||||||||||||
| 01 50 00 | SD-06 - Backflow Preventer Tests | 2.2.4 | ||||||||||||||||
| 01 50 00 | SD-07 - Backflow Tester | 1.4.1 | ||||||||||||||||
| 01 50 00 | SD-07 - Backflow Preventers | 1.4 | ||||||||||||||||
| 01 54 00.00 31 | SD-03 - Affirmative Procurement Reporting Form | 1.5.2.1 | G | |||||||||||||||
| 01 57 19.00 31 | SD-01 - Preconstruction Survey | 1.7.1 | G | |||||||||||||||
| 01 57 19.00 31 | SD-01 - Regulatory Notifications | 1.8.3 | G | |||||||||||||||
| 01 57 19.00 31 | SD-01 - Environmental Protection Plan | 1.5 | G | |||||||||||||||
| 01 57 19.00 31 | SD-01 - Dirt and Dust Control Plan | 1.6 | G | |||||||||||||||
| 01 57 19.00 31 | SD-06 - Disposal Requirements | 3.9.2 | ||||||||||||||||
| 01 57 19.00 31 | SD-06 - Erosion and Sediment Control Inspection Reports | 3.4 | ||||||||||||||||
| 01 57 19.00 31 | SD-06 - Storm Water Inspection Reports for General Permit | 3.4 | ||||||||||||||||
| 01 57 19.00 31 | SD-06 - Solid Waste Disposal Report | 1.8.4 | G | |||||||||||||||
| 01 57 19.00 31 | SD-07 - Contractor 40 CFR employee training records | 1.8.2 | G | |||||||||||||||
| 01 57 19.00 31 | SD-11 - Waste Determination Documentation | 1.8 | ||||||||||||||||
| 01 57 19.00 31 | SD-11 - Waste Determination Documentation | 3.7.2 | ||||||||||||||||
| 01 57 19.00 31 | SD-11 - Disposal Documentation for Hazardous and Regulated Waste | 1.8.1 | ||||||||||||||||
| 01 57 19.00 31 | SD-11 - Contractor 40 CFR Employee Training Records | 1.8.2 | ||||||||||||||||
| 01 57 19.00 31 | SD-11 - Solid Waste Disposal Permit | 1.7.2 | ||||||||||||||||
| 01 57 19.00 31 | SD-11 - Solid Waste Disposal Report | 1.8.4 | ||||||||||||||||
| 01 57 19.00 31 | SD-11 - Hazardous Waste/Debris Management | 3.7.2 | ||||||||||||||||
| 01 57 19.00 31 | SD-11 - Regulatory Notifications | 1.8.3 | ||||||||||||||||
| 01 74 19.00 31 | SD-01 - Construction Waste Management Plan | 1.3.3 | G | |||||||||||||||
| 01 78 00 | SD-03 - Warranty Management Plan | 1.5.1 | ||||||||||||||||
| 01 78 00 | SD-03 - Warranty Tags | 1.5.4 | ||||||||||||||||
| 01 78 00 | SD-03 - Spare Parts Data | 1.4 | ||||||||||||||||
| 01 78 00 | SD-08 - Preventative Maintenance | 3.9 | ||||||||||||||||
| 01 78 00 | SD-08 - Condition Monitoring | 3.9 | ||||||||||||||||
| 01 78 00 | SD-08 - Inspection | 3.9 | ||||||||||||||||
| 01 78 00 | SD-08 - Instructions | 1.5.1 | ||||||||||||||||
| 01 78 00 | SD-10 - Operation and Maintenance Manuals | 3.7 | G | |||||||||||||||
| 01 78 00 | SD-11 - As-Built Drawings | 3.1 | G | |||||||||||||||
| 01 78 00 | SD-11 - Record Drawings | 3.3 | G | |||||||||||||||
| 01 78 00 | SD-11 - As-Built Record of Equipment and Materials | 3.6 | ||||||||||||||||
| 01 78 00 | SD-11 - Final Approved Shop Drawings | 3.4 | ||||||||||||||||
| 01 78 00 | SD-11 - Construction Contract Specifications | 3.5 | ||||||||||||||||
| 01 78 00 | SD-11 - Interim DD FORM 1354 | 3.1 | G | |||||||||||||||
| 01 78 00 | SD-11 - Checklist for DD FORM 1354 | 3.1 | G | |||||||||||||||
| 01 78 23 | SD-10 - O&M Database | 1.4 | G | |||||||||||||||
| 01 78 23 | SD-10 - Training Plan | 3.1.1 | G | |||||||||||||||
| 01 78 23 | SD-10 - Training Outline | 3.1.3 | G | |||||||||||||||
| 01 78 23 | SD-10 - Training Content | 3.1.2 | G | |||||||||||||||
| 01 78 23 | SD-11 - Training Video Recording | 3.1.4 | G | |||||||||||||||
| 01 78 23 | SD-11 - Validation of Training Completion | 3.1.6 | G | |||||||||||||||
| 01 91 00.15 20 | SD-06 - Initial Commissioning Report | 3.8 | G | |||||||||||||||
| 01 91 00.15 20 | SD-06 - Issues Log | 1.1 | G | |||||||||||||||
| 01 91 00.15 20 | SD-06 - Completed Pre-Functional Checklists | 3.5 | G | |||||||||||||||
| 01 91 00.15 20 | SD-07 - Commissioning Firm | 1.8 | G | |||||||||||||||
| 01 91 00.15 20 | SD-07 - Certificate Of Readiness | 1.11 | G | |||||||||||||||
| 01 91 00.15 20 | SD-07 - Final Commissioning Report | 3.8 | G | |||||||||||||||
| 02 41 00 | SD-01 - Demolition Plan | 1.2.2 | G | |||||||||||||||
| 02 41 00 | SD-01 - Existing Conditions | 1.11 | ||||||||||||||||
| 02 41 00 | SD-07 - Notification | 1.7 | G | |||||||||||||||
| 03 30 53 | SD-02 - Installation Drawings | 1.5 | G | |||||||||||||||
| 03 30 53 | SD-03 - Air-Entraining Admixture | 2.2.3.1 | ||||||||||||||||
| 03 30 53 | SD-03 - Water-Reducing or Retarding Admixture | 2.2.3.3 | ||||||||||||||||
| 03 30 53 | SD-03 - Curing Materials | 2.2.11 | ||||||||||||||||
| 03 30 53 | SD-03 - Expansion Joint Filler Strips, Premolded | 2.2.6 | ||||||||||||||||
| 03 30 53 | SD-03 - Joint Sealants - Field Molded Sealants | 2.2.7 | ||||||||||||||||
| 03 30 53 | SD-03 - Conveying and Placing Concrete | 3.2 | ||||||||||||||||
| 03 30 53 | SD-03 - Formwork | 2.2.8 | ||||||||||||||||
| 03 30 53 | SD-03 - Mix Design Data | 2.3 | G | |||||||||||||||
| 03 30 53 | SD-03 - Ready-Mix Concrete | 2.3 | ||||||||||||||||
| 03 30 53 | SD-03 - Curing Compound | 2.4.3 | ||||||||||||||||
| 03 30 53 | SD-03 - Mechanical Reinforcing Bar Connectors | 2.2.5 | ||||||||||||||||
| 03 30 53 | SD-06 - Aggregates | 2.2.2 | ||||||||||||||||
| 03 30 53 | SD-06 - Concrete Mixture Proportions | 2.1.3 | G | |||||||||||||||
| 03 30 53 | SD-06 - Compressive Strength Testing | 3.9.3 | G | |||||||||||||||
| 03 30 53 | SD-06 - Slump | 3.9.3 | G | |||||||||||||||
| 03 30 53 | SD-06 - Air Content | 3.9.3 | ||||||||||||||||
| 03 30 53 | SD-06 - Water | 2.2.4 | ||||||||||||||||
| 03 30 53 | SD-07 - Cementitious Materials | 2.2.1 | ||||||||||||||||
| 03 30 53 | SD-07 - Pozzolan | 2.2.1.2 | ||||||||||||||||
| 03 30 53 | SD-07 - Aggregates | 2.2.2 | ||||||||||||||||
| 03 30 53 | SD-07 - Delivery Tickets | 2.3 | ||||||||||||||||
| 03 30 53 | SD-08 - Curing Compound | 2.4.3 | ||||||||||||||||
| 05 40 00 | SD-03 - Studs, Joists | 2.1 | ||||||||||||||||
| 05 40 00 | SD-07 - Load-Bearing Cold-Formed Metal Framing | 1.4 | ||||||||||||||||
| 07 84 00 | SD-02 - Firestopping System | 2.1 | G | |||||||||||||||
| 07 84 00 | SD -03 - Firestopping Materials | 2.2 | G | |||||||||||||||
| 07 84 00 | SD-06 - Inspection | 3.3 | G | |||||||||||||||
| 07 84 00 | SD-07 - Inspector Qualifications | 1.5.2 | ||||||||||||||||
| 07 84 00 | SD-07 - Firestopping Materials | 2.2 | ||||||||||||||||
| 07 84 00 | SD-07 - Installer Qualifications | 1.5.1 | G | |||||||||||||||
| 07 92 00 | SD-03 - Sealants | 2.1 | G | |||||||||||||||
| 07 92 00 | SD-03 - Primers | 2.2 | G | |||||||||||||||
| 07 92 00 | SD-03 - Bond Breakers | 2.3 | G | |||||||||||||||
| 07 92 00 | SD-03 - Backstops | 2.4 | G | |||||||||||||||
| 07 92 00 | SD-03 - Field Adhesion | 3.1 | G | |||||||||||||||
| 07 92 00 | SD-03 - Indoor Air Quality For Interior Sealants | 2.1.1 | ||||||||||||||||
| 07 92 00 | SD-03 - Indoor Air Quality For Interior Acoustical Sealants | 2.1.3 | ||||||||||||||||
| 07 92 00 | SD-03 - Indoor Air Quality For Interior Caulking | 2.5 | ||||||||||||||||
| 08 11 13 | SD-02 - Doors | 2.1 | G | |||||||||||||||
| 08 11 13 | SD-02 - Frames | 2.6 | G | |||||||||||||||
| 08 11 13 | SD-02 - Schedule of Doors | 2.1 | G | |||||||||||||||
| 08 11 13 | SD-02 - Schedule of Frames | 2.1 | G | |||||||||||||||
| 08 11 13 | SD-03 - Doors | 2.1 | G | |||||||||||||||
| 08 11 13 | SD-03 - Recycled Content for Steel Door Product | 2.1 | ||||||||||||||||
| 08 11 13 | SD-03 - Frames | 2.6 | G | |||||||||||||||
| 08 11 13 | SD-03 - Recycled Content for Steel Frame Product | 2.6 | ||||||||||||||||
| 08 51 13 | SD-02 -Windows | 2.1 | G | |||||||||||||||
| 08 51 13 | SD-02 -Fabrication Drawings | 1.7 | ||||||||||||||||
| 08 51 13 | SD-03 - Windows | 2.1 | G | |||||||||||||||
| 08 51 13 | SD-03 - Fasteners | 2.2.2 | G | |||||||||||||||
| 08 51 13 | SD-03 - Windows Performance | 1.8 | G | |||||||||||||||
| 08 51 13 | SD-03 - Thermail-Barrier Windows | 2.3 | G | |||||||||||||||
| 08 51 13 | SD-03 - Windows Cleaners' Bolts | 2.4 | G | |||||||||||||||
| 08 51 13 | SD-03 - Weatherstripping | 2.1.4 | G | |||||||||||||||
| 08 51 13 | SD-03 - Accessories | 2.2.5 | G | |||||||||||||||
| 08 51 13 | SD-03 - Adhesives | 2.2.3 | ||||||||||||||||
| 08 51 13 | SD-03 - Thermal Performance | 1.8.4 | G | |||||||||||||||
| 08 51 13 | SD-04 - Finish Sample | 1.3.3.1 | ||||||||||||||||
| 08 51 13 | SD-04 - Window Sample | 1.3.3.2 | ||||||||||||||||
| 08 51 13 | SD-05 - Structural Calculations for Deflection | 2.1 | G | |||||||||||||||
| 08 51 13 | SD-05 - Design Analysis | 1.3.4 | G | |||||||||||||||
| 08 51 13 | SD-06 - Minimum Condensation Resistance Factor | 1.3.5 | ||||||||||||||||
| 08 51 13 | SD-06 - Windborne-Debris-Impact Performance | 1.8.5 | ||||||||||||||||
| 08 51 13 | SD-10 - Windows | 2.1 | G | |||||||||||||||
| 08 51 13 | SD-10 - Plastic Identification | 1.5 | ||||||||||||||||
| 08 71 00 | SD-02 - Manufacturer's Detail Drawings | 1.3 | G | |||||||||||||||
| 08 71 00 | SD-02 - Verification of Existing Conditions | 1.3 | G | |||||||||||||||
| 08 71 00 | SD-02 - Hardware Schedule | 1.5 | G | |||||||||||||||
| 08 71 00 | SD-02 - Keying System | 2.3.11 | G | |||||||||||||||
| 08 71 00 | SD-03 - Hardware Items | 2.3 | G | |||||||||||||||
| 08 71 00 | SD-08 - Installation | 3.1 | ||||||||||||||||
| 08 71 00 | SD-10 - Hardware Schedule | 1.5 | G | |||||||||||||||
| 08 71 00 | SD-11 - Key Bitting | 1.6.1 | ||||||||||||||||
| 08 81 00 | SD-03 - Glazing Accessories | 1.3 | ||||||||||||||||
| 08 81 00 | SD-03 - Sealants | 2.2.2.1 | ||||||||||||||||
| 08 81 00 | SD-03 - Joint Backer | 2.2.3 | ||||||||||||||||
| 08 81 00 | SD-04 - Tape | 2.2.5 | ||||||||||||||||
| 08 81 00 | SD-04 - Sealing Tapes | 2.2.5 | ||||||||||||||||
| 08 81 00 | SD-08 - Setting and Sealing Materials | 2.2 | ||||||||||||||||
| 08 81 00 | SD-08 - Glass Setting | 3.2 | ||||||||||||||||
| 08 81 00 | SD-11 - Insulated Glass Units | 1.7.1 | ||||||||||||||||
| 09 22 00 | SD-02 - Metal Support Systems | 2.1 | G | |||||||||||||||
| 09 22 00 | SD-03 - Metal Support Systems | 2.1 | ||||||||||||||||
| 09 22 00 | SD-03 - Recycled Content for Metal Support Systems | 2.1 | ||||||||||||||||
| 09 29 00 | SD-03 - Accessories | 2.1.15 | ||||||||||||||||
| 09 29 00 | SD-03 - Gypsum Board | 2.1.1 | ||||||||||||||||
| 09 29 00 | SD-03 - Recycled Content for Gypsum Board | 2.1.1 | ||||||||||||||||
| 09 29 00 | SD-03 - Recycled Content for Paper Facing and Gypsum Cores | 2.1.1 | ||||||||||||||||
| 09 29 00 | SD-03 - VOC Content of Joint Compound | 2.1.10 | ||||||||||||||||
| 09 29 00 | SD-07 - Asbestos Free Materials | 2.1 | G | |||||||||||||||
| 09 29 00 | SD-07 - Indoor Air Quality for Gypsum Board | 2.1.1 | ||||||||||||||||
| 09 29 00 | SD-07 - Indoor Air Quality for Non-aerosol Adhesives | 2.1.12 | ||||||||||||||||
| 09 29 00 | SD-07 - Indoor Air Quality for Aerosol Adhesives | 2.1.12 | ||||||||||||||||
| 09 29 00 | SD-08 - Safety Data Sheets | 2.1 | ||||||||||||||||
| 09 29 00 | SD-10 - Manufacturer Maintenance Instructions | 2.1 | ||||||||||||||||
| 09 51 00 | SD-02 - Approved Detail Drawings | 2.1 | ||||||||||||||||
| 09 51 00 | SD-03 - Acoustical Ceiling Systems | 2.1.1 | ||||||||||||||||
| 09 51 00 | SD-03 - Recycled Content for Type III Ceiling Tiles | 2.2.1.1 | ||||||||||||||||
| 09 51 00 | SD-03 - Recycled Content for Suspension Systems | 2.3 | ||||||||||||||||
| 09 51 00 | SD-03 - Acoustical Performance | 2.1.2 | ||||||||||||||||
| 09 51 00 | SD-04 - Acoustical Units | 2.2 | ||||||||||||||||
| 09 51 00 | SD-04 - Acoustical Ceiling Tiles | 2.2.1.1 | ||||||||||||||||
| 09 51 00 | SD-07 - Indoor Air Quality for Type III Ceiling Tiles | 2.2.1.1 | ||||||||||||||||
| 09 51 00 | SD-07 - Indoor Air Quality for Adhesives | 2.6 | ||||||||||||||||
| 09 51 00 | SD-07 - Indoor Air Quality for Sealants | 2.9 | ||||||||||||||||
| 09 62 38 | SD-03 - Static-Control Resilient Flooring | 2.1 | G | |||||||||||||||
| 09 62 38 | SD-03 - Recycled content for Static-Dissipative Vinyl Tile | 2.1.2.1 | ||||||||||||||||
| 09 62 38 | SD-03 - Accessories | 2.6 | G | |||||||||||||||
| 09 62 38 | SD-03 - Adhesives | 2.4 | G | |||||||||||||||
| 09 62 38 | SD-03 - Warranty | 1.9 | ||||||||||||||||
| 09 62 38 | SD-04 - Static-Control Resilient Flooring | 2.1 | G | |||||||||||||||
| 09 62 38 | SD-04 - Moldings | 2.5 | G | |||||||||||||||
| 09 62 38 | SD-04 - Special Treatment Materials | 1.3.1.4 | G | |||||||||||||||
| 09 62 38 | SD-04 - Accessories | 2.6 | G | |||||||||||||||
| 09 62 38 | SD-06 - Fire Resistance | 2.9 | ||||||||||||||||
| 09 62 38 | SD-06 - Moisture, Alkalinity and Bond | 3.2 | ||||||||||||||||
| 09 62 38 | SD-06 - Testing | 3.9 | ||||||||||||||||
| 09 62 38 | SD-07 - Indoor Air Quality for Static-Dissipative Vinyl Tile | 2.1.2.1 | ||||||||||||||||
| 09 62 38 | SD-07 - Indoor Air Quality for Adhesives | 2.4 | ||||||||||||||||
| 09 62 38 | SD-07 - Qualifications of Applicator | 1.6 | ||||||||||||||||
| 09 62 38 | SD-08 - Static-Control Resilient Flooring | 2.1 | G | |||||||||||||||
| 09 62 38 | SD-08 - Accessories | 2.6 | G | |||||||||||||||
| 09 90 00 | SD-02 - Piping Identification | 3.12 | ||||||||||||||||
| 09 90 00 | SD-03 - Coating | 2.1 | G | |||||||||||||||
| 09 90 00 | SD-03 - Product Data Sheets | 2.1 | ||||||||||||||||
| 09 90 00 | SD-04 - Color | 2.3 | G | |||||||||||||||
| 09 90 00 | SD-07 - Qualification Testing | 1.6.6.2 | G | |||||||||||||||
| 09 90 00 | SD-07 - Indoor Air Quality for Paints and Primers | 1.6.5 | ||||||||||||||||
| 09 90 00 | SD-08 - Application Instructions | 3.4.1 | ||||||||||||||||
| 09 90 00 | SD-08 - Mixing | 2.1 | ||||||||||||||||
| 09 90 00 | SD-08 - Manufacturer's Safety Data Sheets | 1.8.1 | ||||||||||||||||
| 09 90 00 | SD-10 - Coatings | 2.1 | G | |||||||||||||||
| 10 14 00.20 | SD-02 - Detail Drawings | 1.3.2 | G | |||||||||||||||
| 10 14 00.20 | SD-03 - Door Tags | 2.2 | G | |||||||||||||||
| 10 14 00.20 | SD-04 - Interior Signage | 1.3.1 | G | |||||||||||||||
| 10 14 00.20 | SD-04 - Door Tags | 2.2 | G | |||||||||||||||
| 10 14 00.20 | SD-10 - Approved Manufacturer's Instructions | 3.1 | G | |||||||||||||||
| 10 14 00.20 | SD-10 - Protection and Cleaning | 3.1.2 | G | |||||||||||||||
| 10 44 16 | SD-02 - Fire Extinguishers | 2.1.1 | G | |||||||||||||||
| 10 44 16 | SD-02 - Accessories | Part 2 | G | |||||||||||||||
| 10 44 16 | SD-02 - Cabinets | Part 2 | G | |||||||||||||||
| 10 44 16 | SD-02 - Schedule | 1.5 | G | |||||||||||||||
| 10 44 16 | SD-03 - Fire Extinguishers | 2.1.1 | G | |||||||||||||||
| 10 44 16 | SD-03 - Accessories | Part 2 | G | |||||||||||||||
| 10 44 16 | SD-03 - Cabinets | Part 2 | G | |||||||||||||||
| 10 44 16 | SD-03 - Replacement Parts List | 3.2.1 | G | |||||||||||||||
| 10 44 16 | SD-04 - Equipment Samples | 1.3.1 | G | |||||||||||||||
| 10 44 16 | SD-07 - Fire Extinguishers Certifications | 2.1.1 | G | |||||||||||||||
| 10 44 16 | SD-07 - Manufacturer's Warranty with Inspection Tag | 1.4 | G | |||||||||||||||
| 21 13 13 | SD-01 - Qualified Fire Protection Engineer (QFPE) | 1.2.3 | G | |||||||||||||||
| 21 13 13 | SD-01 - Sprinkler System Designer | 1.4.2.1 | G | |||||||||||||||
| 21 13 13 | SD-01 - Sprinkler System Installer | 1.4.2.2 | G | |||||||||||||||
| 21 13 13 | SD-02 - Shop Drawing | 1.2.1.1 | G | |||||||||||||||
| 21 13 13 | SD-03 - Fittings | 2.3.1.2 | G | |||||||||||||||
| 21 13 13 | SD-03 - Valves | 2.3.6 | G | |||||||||||||||
| 21 13 13 | SD-03 - Alarm Valves | 2.3.5 | G | |||||||||||||||
| 21 13 13 | SD-03 - Relief Valves | 2.6.3 | G | |||||||||||||||
| 21 13 13 | SD-03 - Sprinklers | 2.7 | G | |||||||||||||||
| 21 13 13 | SD-03 - Pipe Hangers and Supports | 2.3.5 | G | |||||||||||||||
| 21 13 13 | SD-03 - Sprinkler Alarm Switch | 2.4.1 | G | |||||||||||||||
| 21 13 13 | SD-03 - Valve Supervisory (Tamper) Switch | 2.4.2 | G | |||||||||||||||
| 21 13 13 | SD-03 - Air Vent | 2.8.6 | G | |||||||||||||||
| 21 13 13 | SD-03 - Seismic Bracing | 2.3.3 | G | |||||||||||||||
| 21 13 13 | SD-03 - Nameplates | 2.1.2 | G | |||||||||||||||
| 21 13 13 | SD-05 - Seismic Bracing | 2.3.3 | G | |||||||||||||||
| 21 13 13 | SD-05 - Hydraulic Calculations | 1.2.1.2 | G | |||||||||||||||
| 21 13 13 | SD-06 - Test Procedures | 3.7.1 | G | |||||||||||||||
| 21 13 13 | SD-07 - Verification of Compliant Installation | 3.7.2.1 | G | |||||||||||||||
| 21 13 13 | SD-07 - Request for Government Final Test | 3.7.2.2 | G | |||||||||||||||
| 21 13 13 | SD-10 - Operating and Maintenance (O&M) Instructions | 3.9 | G | |||||||||||||||
| 21 13 13 | SD-10 - Spare Parts | 1.6 | G | |||||||||||||||
| 21 13 13 | SD-11 - As-built drawings | 3.9 | ||||||||||||||||
| 22 00 00 | SD-02 - Plumbing System | 3.9.1 | G | |||||||||||||||
| 22 00 00 | SD-03 - Backflow Prevention Assemblies | 3.9.1.1 | G | |||||||||||||||
| 22 00 00 | SD-03 - Welding | 1.5.1 | ||||||||||||||||
| 22 00 00 | SD-03 - Plumbing System | 3.9.1 | ||||||||||||||||
| 22 00 00 | SD-06 - Tests, Flushing and Disinfection | 3.9 | ||||||||||||||||
| 22 00 00 | SD-06 - Test of Backflow Prevention Assemblies | 3.9.1.1 | G | |||||||||||||||
| 22 00 00 | SD-07 - Materials and Equipment | 1.3 | ||||||||||||||||
| 22 00 00 | SD-07 - Bolts | 2.1.1 | ||||||||||||||||
| 22 00 00 | SD-10 - Plumbing System | 3.9.1 | G | |||||||||||||||
| 23 05 48.19 | SD-02 - Coupling and Bracing | 3.1 | ||||||||||||||||
| 23 05 48.19 | SD-02 - Flexible Couplings or Joints | 3.3 | ||||||||||||||||
| 23 05 48.19 | SD-02 - Equipment Restraint | 2.2 | ||||||||||||||||
| 23 05 48.19 | SD-02 - Contractor Designed Bracing | 1.2.4 | G | |||||||||||||||
| 23 05 48.19 | SD-03 - Coupling and Bracing | 3.1 | G | |||||||||||||||
| 23 05 48.19 | SD-03 - Flexible Couplings Or Joints | 3.3 | G | |||||||||||||||
| 23 05 48.19 | SD-03 - Equipment Restraint | 2.2 | G | |||||||||||||||
| 23 05 48.19 | SD-03 - Contractor Designed Bracing | 1.2.4 | G | |||||||||||||||
| 23 05 48.19 | SD-03 - Snubbers | 2.6 | ||||||||||||||||
| 23 05 48.19 | SD-03 - Anchor Bolts | 3.9 | ||||||||||||||||
| 23 05 48.19 | SD-03 - Vibration Isolators | 2.2.2 | ||||||||||||||||
| 23 05 48.19 | SD-05 - Design Calculations | 1.2.4 | ||||||||||||||||
| 23 05 48.19 | SD-06 - Anchor Bolts | 3.9 | G | |||||||||||||||
| 23 05 93 | SD-01 - Records of Existing Conditions | 1.3.3 | G | |||||||||||||||
| 23 05 93 | SD-01 - Independent TAB Agency and Personnel Qualifications | 1.5.1 | G | |||||||||||||||
| 23 05 93 | SD-01 - TAB Design Review Report | 1.5.3.1 | G | |||||||||||||||
| 23 05 93 | SD-02 - TAB Schematic Drawings and Report Forms | 1.3.3 | G | |||||||||||||||
| 23 05 93 | SD-03 - Equipment and Performance Data | 1.3 | G | |||||||||||||||
| 23 05 93 | SD-03 - TAB Related HVAC Submittals | 1.3 | G | |||||||||||||||
| 23 05 93 | SD-06 - Completed Pre-Final DALT Report | 3.3.5 | G | |||||||||||||||
| 23 05 93 | SD-06 - Certified Final DALT Report | 3.3.8 | G | |||||||||||||||
| 23 05 93 | SD-06 - Prerequisite HVAC Work Checkout List | 1.5.3.2 | G | |||||||||||||||
| 23 05 93 | SD-06 - Prerequisite HVAC Work Checkout List | 1.5.3.2 | G | |||||||||||||||
| 23 05 93 | SD-06 - Prerequisite HVAC Work Checkout List | 1.5.3.2 | G | |||||||||||||||
| 23 05 93 | SD-06 - Proportional Balancing | 3.7 | G | |||||||||||||||
| 23 05 93 | SD-07 - Independent TAB Agency and Personnel Qualifications | 1.5.1 | G | |||||||||||||||
| 23 05 93 | SD-07 - DALT and TAB Submittal and Work Schedule | 1.5.3.1 | G | |||||||||||||||
| 23 05 93 | SD-07 - TAB Pre-Field Engineering Report | 1.5.3.2 | G | |||||||||||||||
| 23 05 93 | SD-07 - Instrument Calibration Certificates | 1.5.5 | G | |||||||||||||||
| 23 05 93 | SD-07 - DALT and TAB Procedures Summary | 3.7 | G | |||||||||||||||
| 23 05 93 | SD-07 - Completed Pre-Final DALT Work Checklist | 3.7 | G | |||||||||||||||
| 23 05 93 | SD-07 - Advance Notice of Pre-Final DALT Field Work | 3.3.2 | G | |||||||||||||||
| 23 05 93 | SD-07 - Proportional Balancing | 3.7 | G | |||||||||||||||
| 23 07 00 | SD-02 - MICA Plates | 3.2.2.4 | G | |||||||||||||||
| 23 07 00 | SD-02 - Pipe Insulation Systems | 2.3 | ||||||||||||||||
| 23 07 00 | SD-02 - Pipe Insulation Systems | 3.2 | ||||||||||||||||
| 23 07 00 | SD-02 - Duct Insulation Systems | 3.3 | ||||||||||||||||
| 23 07 00 | SD-02 - Equipment Insulation Systems | 3.4 | ||||||||||||||||
| 23 07 00 | SD-03 - Pipe Insulation Systems | 2.3 | G | |||||||||||||||
| 23 07 00 | SD-03 - Pipe Insulation Systems | 3.2 | G | |||||||||||||||
| 23 07 00 | SD-03 - Duct Insulation Systems | 3.3 | G | |||||||||||||||
| 23 07 00 | SD-03 - Equipment Insulation Systems | 3.4 | G | |||||||||||||||
| 23 07 00 | SD-04 - Thermal Insulation | 2.2.1.3 | G | |||||||||||||||
| 23 07 00 | SD-07 - Indoor air quality for adhesives | 2.2.1 | G | |||||||||||||||
| 23 07 00 | SD-08 - Pipe Insulation Systems | 2.3 | G | |||||||||||||||
| 23 07 00 | SD-08 - Pipe Insulation Systems | 3.2 | G | |||||||||||||||
| 23 07 00 | SD-08 - Duct Insulation Systems | 3.3 | G | |||||||||||||||
| 23 07 00 | SD-08 - Equipment Insulation Systems | 3.4 | G | |||||||||||||||
| 23 09 00 | SD-02 - DDC Contractor Design Drawings | 3.3 | G | |||||||||||||||
| 23 09 00 | SD-02 - Draft As-Built Drawings | 3.3 | G | |||||||||||||||
| 23 09 00 | SD-02 - Final As-Built Drawings | 3.3 | G | |||||||||||||||
| 23 09 00 | SD-03 - Programming Software | G | ||||||||||||||||
| 23 09 00 | SD-03 - Controller Application Programs | G | ||||||||||||||||
| 23 09 00 | SD-03 - Configuration Software | G | ||||||||||||||||
| 23 09 00 | SD-03 - Controller Configuration Settings | 1.8.2 | G | |||||||||||||||
| 23 09 00 | SD-03 - Proprietary Multi-Split Engineering Tool Software | 1.1.1.2 | G | |||||||||||||||
| 23 09 00 | SD-03 - Manufacturer's Product Data | 2.2 | G | |||||||||||||||
| 23 09 00 | SD-06 - Existing Conditions Report | 3.1.1 | ||||||||||||||||
| 23 09 00 | SD-06 - Pre-Construction Quality Control (QC) Checklist | 1.10.1 | G | |||||||||||||||
| 23 09 00 | SD-06 - Post-Construction Quality Control (QC) Checklist | 1.10.2 | G | |||||||||||||||
| 23 09 00 | SD-06 - Start-Up Testing Report | 3.5.2 | G | |||||||||||||||
| 23 09 00 | SD-06 - PVT Procedures | 3.6.1 | G | |||||||||||||||
| 23 09 00 | SD-06 - PVT Report | 3.6.3 | G | |||||||||||||||
| 23 09 00 | SD-10 - Operation and Maintenance (O&M) Instructions | 3.8 | G | |||||||||||||||
| 23 09 00 | SD-10 - Training Documentation | 3.10.1 | G | |||||||||||||||
| 23 09 00 | SD-11 - Enclosure Keys | 2.5 | G | |||||||||||||||
| 23 09 00 | SD-11 - Password Summary Report | 3.2.6.1 | G | |||||||||||||||
| 23 09 00 | SD-11 - Closeout Quality Control (QC) Checklist | 1.10.3 | G | |||||||||||||||
| 23 23 00 | SD-02 - Refrigerant Piping System | 2.3 | G | |||||||||||||||
| 23 23 00 | SD-03 - Refrigerant Piping System | 2.3 | ||||||||||||||||
| 23 23 00 | SD-03 - Qualifications | 1.3.1 | ||||||||||||||||
| 23 23 00 | SD-03 - Refrigerant Piping Tests | 3.5 | ||||||||||||||||
| 23 23 00 | SD-03 - Verification of Dimensions | 3.1 | ||||||||||||||||
| 23 23 00 | SD-06 - Refrigerant Piping Tests | 3.5 | ||||||||||||||||
| 23 23 00 | SD-07 - Service Organization | 2.1 | ||||||||||||||||
| 23 23 00 | SD-10 - Maintenance | 1.5 | G | |||||||||||||||
| 23 23 00 | SD-10 - Operation and Maintenance Manuals | 3.4 | G | |||||||||||||||
| 23 23 00 | SD-10 - Demonstrations | 3.4 | G | |||||||||||||||
| 23 30 00 | SD-02 - Detail Drawings | 1.4.4 | G | |||||||||||||||
| 23 30 00 | SD-03 - Insulated Nonmetallic Flexible Duct Runouts | 2.9.1.2 | ||||||||||||||||
| 23 30 00 | SD-03 - Duct Connectors | 2.9.1.2 | ||||||||||||||||
| 23 30 00 | SD-03 - Duct Access Doors | 2.9.2 | G | |||||||||||||||
| 23 30 00 | SD-03 - Manual Balancing Dampers | 2.9.4 | G | |||||||||||||||
| 23 30 00 | SD-03 - Diffusers | 2.9.10.1 | ||||||||||||||||
| 23 30 00 | SD-03 - Registers and Grilles | 2.9.10.5 | ||||||||||||||||
| 23 30 00 | SD-03 - Variable Volume, Single Duct Terminal Units | 2.12.3.2 | G | |||||||||||||||
| 23 30 00 | SD-03 - Test Procedures | 1.4.5 | ||||||||||||||||
| 23 30 00 | SD-03 - Diagrams | 1.2.1.2 | G | |||||||||||||||
| 23 30 00 | SD-03 - Indoor Air Quality for Duct Sealants | 2.9.1 | ||||||||||||||||
| 23 30 00 | SD-06 - Performance Tests | 3.12 | G | |||||||||||||||
| 23 30 00 | SD-06 - Damper Acceptance Test | 3.9 | G | |||||||||||||||
| 23 30 00 | SD-08 - Manufacturer's Installation Instructions | 3.2 | ||||||||||||||||
| 23 30 00 | SD-08 - Operation and Maintenance Training | 3.15.2 | ||||||||||||||||
| 23 30 00 | SD-10 - Operation and Maintenance Manuals | 3.15.1 | G | |||||||||||||||
| 23 30 00 | SD-10 - Manual Balancing Dampers | 2.9.4 | G | |||||||||||||||
| 23 30 00 | SD-10 - Variable Volume, Single Duct, Fan-Powered Terminal Units | 2.8.1.1 | G | |||||||||||||||
| 23 30 00 | SD-10 - Reheat Units | 2.8.1.2 | G | |||||||||||||||
| 23 30 00 | SD-11 - Indoor Air Quality During Construction | 3.13 | ||||||||||||||||
| 23 81 23 | SD-03 - Computer Room Air Conditioner | 2.1 | G | |||||||||||||||
| 23 81 23 | SD-03 - Space Temperature Control System Drawings | 2.8.3 | G | |||||||||||||||
| 23 81 23 | SD-03 - Filters | 2.1.5 | ||||||||||||||||
| 23 81 23 | SD-03 - Refrigerants | 1.4 | ||||||||||||||||
| 23 81 23 | SD-03 - Hot Aisle Containment Systems | 2.3 | G | |||||||||||||||
| 23 81 23 | SD-03 - Rack Mounted Fans | 2.4 | G | |||||||||||||||
| 23 81 23 | SD-03 - Leak Detection | 2.5.1.3 | G | |||||||||||||||
| 23 81 23 | SD-06 - CRAC Production Schedule and Factory Test Schedule | 2.11.2 | G | |||||||||||||||
| 23 81 23 | SD-06 - Manufacturer's Factory Test Plans | 2.11.1 | G | |||||||||||||||
| 23 81 23 | SD-06 - Factory Test Reports | 2.11.5 | G | |||||||||||||||
| 23 81 23 | SD-06 - Field Test Schedule | 3.3.2 | G | |||||||||||||||
| 23 81 23 | SD-06 - Manufacturer's Field Test Plans | 3.3.1 | G | |||||||||||||||
| 23 81 23 | SD-06 - Field Test Reports | 3.3.6 | G | |||||||||||||||
| 23 81 23 | SD-07 - Certificate of Specification Compliance | 2.6 | G | |||||||||||||||
| 23 81 23 | SD-07 - Credentials of the Manufacturer's Field Test Representative | 3.3.3 | G | |||||||||||||||
| 23 81 23 | SD-07 - Ozone Depleting Substances Technician Certification | 1.5.1 | ||||||||||||||||
| 23 81 23 | SD-07 - Certified List Of Qualified Permanent Service Organizations | 1.6.3 | ||||||||||||||||
| 23 81 23 | SD-08 - Installation Manual for Each Type of CRAC | 3.1.2 | ||||||||||||||||
| 23 81 23 | SD-08 - Installation Manual for Each Type of Aisle Containment System | 3.1.2 | ||||||||||||||||
| 23 81 23 | SD-10 - Computer Room Air Conditioner Operation and Maintenance Data | 3.1.3 | G | |||||||||||||||
| 23 81 23 | SD-11 - Indoor Air Quality During Construction | 3.2 | ||||||||||||||||
| 26 05 48.00 10 | SD-02 - Luminaires in Buildings | 3.2 | G | |||||||||||||||
| 26 05 48.00 10 | SD-02 - Equipment Requirements | 1.3 | G | |||||||||||||||
| 26 05 48.00 10 | SD-03 - Luminaires in Buildings | 3.2 | G | |||||||||||||||
| 26 05 48.00 10 | SD-03 - Equipment Requirements | 1.3 | G | |||||||||||||||
| 26 05 48.00 10 | SD-03 - Contractor Designed Bracing | 1.2.4 | G | |||||||||||||||
| 26 20 00 | SD-02 - Panelboards | 2.15 | G | |||||||||||||||
| 26 20 00 | SD-02 - Transformers | 2.2 | G | |||||||||||||||
| 26 20 00 | SD-02 - Busway | 2.4 | G | |||||||||||||||
| 26 20 00 | SD-02 - Cable Trays | 2.5 | G | |||||||||||||||
| 26 20 00 | SD-02 - Wireways | 2.23 | G | |||||||||||||||
| 26 20 00 | SD-02 - Marking Strips | 3.1.14.1 | G | |||||||||||||||
| 26 20 00 | SD-03 - Receptacles | 2.14 | G | |||||||||||||||
| 26 20 00 | SD-03 - Circuit Breakers | 2.13.3 | G | |||||||||||||||
| 26 20 00 | SD-03 - Switches | 2.11 | G | |||||||||||||||
| 26 20 00 | SD-03 - Transformers | 2.15 | G | |||||||||||||||
| 26 20 00 | SD-03 - Enclosed Circuit Breakers | 2.14 | G | |||||||||||||||
| 26 20 00 | SD-03 - Secondary Bonding Busbar | 2.18.1 | G | |||||||||||||||
| 26 20 00 | SD-03 - Surge Protective Devices | 2.37 | G | |||||||||||||||
| 26 20 00 | SD-06 - 600-volt Wiring Test | 3.5.2 | G | |||||||||||||||
| 26 20 00 | SD-06 - Grounding System Test | 3.5.6 | G | |||||||||||||||
| 26 20 00 | SD-06 - Transformer Tests | 3.5.3 | G | |||||||||||||||
| 26 20 00 | SD-06 - Ground-fault Receptacle Test | 3.5.4 | G | |||||||||||||||
| 26 20 00 | SD-09 - Transformer Factory Tests | 2.39.1 | ||||||||||||||||
| 26 20 00 | SD-10 - Electrical Systems | 1.5.1 | G | |||||||||||||||
| 26 33 53 | SD-02 - UPS Drawings | 1.5.1 | G | |||||||||||||||
| 26 33 53 | SD-02 - UPS Installation | 1.5.2 | G | |||||||||||||||
| 26 33 53 | SD-03 - UPS Module | 2.5 | G | |||||||||||||||
| 26 33 53 | SD-03 - Technical Requirements UPS System | 2.4 | ||||||||||||||||
| 26 33 53 | SD-03 - Spare Parts | G | ||||||||||||||||
| 26 33 53 | SD-03 - Internet Protocol (Ip) Communications And Data Acquisition Port | 2.9 | G | |||||||||||||||
| 26 33 53 | SD-06 - Work Plan | 1.5.3 | G | |||||||||||||||
| 26 33 53 | SD-06 - Factory Test Plan | 1.5.4 | G | |||||||||||||||
| 26 33 53 | SD-06 - Factory Test Report | 1.5.5 | G | |||||||||||||||
| 26 33 53 | SD-09 - Initial Inspection and Tests | 3.2.2 | G | |||||||||||||||
| 26 33 53 | SD-09 - Performance Tests | 3.2.3 | G | |||||||||||||||
| 26 33 53 | SD-09 - Performance Test Plan | 1.5.6 | G | |||||||||||||||
| 26 33 53 | SD-09 - Performance Test Report | 1.5.7 | G | |||||||||||||||
| 26 33 53 | SD-10 - UPS Operation and Maintenance | 1.4.1 | G | |||||||||||||||
| 26 33 53 | SD-11 - Installation | 3.1 | ||||||||||||||||
| 26 51 00 | SD-03 - Luminaires | 2.2 | G | |||||||||||||||
| 26 51 00 | SD-03 - Light Sources | 2.3 | G | |||||||||||||||
| 26 51 00 | SD-03 - LED Drivers | 2.4 | G | |||||||||||||||
| 26 51 00 | SD-03 - Luminaire Warranty | 1.6.1 | G | |||||||||||||||
| 26 51 00 | SD-03 - Switches | 2.5.2.1 | G | |||||||||||||||
| 26 51 00 | SD-03 - Exit Signs | 2.6.1 | G | |||||||||||||||
| 26 51 00 | SD-03 - Emergency Drivers | 2.6.3 | G | |||||||||||||||
| 26 51 00 | SD-05 - Luminaire Design Data | 1.5.2 | G | |||||||||||||||
| 26 51 00 | SD-06 - ANSI/IES LM-79 Test Report | 1.5.3 | G | |||||||||||||||
| 26 51 00 | SD-06 - ANSI/IES LM-80 Test Report | 1.5.4 | G | |||||||||||||||
| 26 51 00 | SD-06 - ANSI/IES TM-21 Test Report | 1.5.5 | G | |||||||||||||||
| 26 51 00 | SD-06 - ANSI/IES TM-30 Test Report | 1.5.6 | G | |||||||||||||||
| 27 10 00 | SD-02 - Telecommunications Space Drawings | 1.6.1.2 | G | |||||||||||||||
| 27 10 00 | SD-03 - Telecommunications cabling | 2.3 | G | |||||||||||||||
| 27 10 00 | SD-03 - Patch panels | 2.4.5 | G | |||||||||||||||
| 27 10 00 | SD-03 - Telecommunications outlet/connector assemblies | 2.5 | G | |||||||||||||||
| 27 10 00 | SD-03 - Equipment support frame | 2.4.2 | G | |||||||||||||||
| 27 10 00 | SD-03 - Spare Parts | 1.10.3 | G | |||||||||||||||
| 27 10 00 | SD-06 - Telecommunications cabling testing | 3.5.1 | G | |||||||||||||||
| 27 10 00 | SD-07 - Telecommunications Contractor | 1.6.2.1 | G | |||||||||||||||
| 27 10 00 | SD-07 - Key Personnel | 1.6.2.2 | G | |||||||||||||||
| 27 10 00 | SD-07 - Manufacturer Qualifications | 1.6.2.3 | G | |||||||||||||||
| 27 10 00 | SD-07 - Test plan | 1.6.3 | G | |||||||||||||||
| 27 10 00 | SD-09 - Factory reel tests | 2.12.1 | G | |||||||||||||||
| 27 10 00 | SD-10 - Telecommunications cabling and pathway system | 1.10.1 | G | |||||||||||||||
| 27 10 00 | SD-11 - Record Documentation | 1.10.2 | G | |||||||||||||||
| 28 31 70 | SD-01 - Qualified Fire Protection Engineer (QFPE) | 1.3.2 | G | |||||||||||||||
| 28 31 70 | SD-01 - Fire alarm system designer | 1.9.2.1 | G | |||||||||||||||
| 28 31 70 | SD-01 - Supervisor | 1.9.2.2 | G | |||||||||||||||
| 28 31 70 | SD-01 - Technician | 1.9.2.3 | G | |||||||||||||||
| 28 31 70 | SD-01 - Installer | 1.9.2.4 | G | |||||||||||||||
| 28 31 70 | SD-01 - Test Technician | 1.9.2.5 | G | |||||||||||||||
| 28 31 70 | SD-01 - Fire Alarm System Site-Specific Software Acknowledgement | 1.7 | G | |||||||||||||||
| 28 31 70 | SD-02 - Nameplates | 1.9.1.3 | G | |||||||||||||||
| 28 31 70 | SD-02 - Instructions | 2.2.4 | G | |||||||||||||||
| 28 31 70 | SD-02 - Wiring Diagrams | 1.9.1.4 | G | |||||||||||||||
| 28 31 70 | SD-02 - System Layout | 1.9.1.5 | G | |||||||||||||||
| 28 31 70 | SD-02 - Notification Appliances | 1.9.1.6 | G | |||||||||||||||
| 28 31 70 | SD-02 - Initiating devices | 1.9.1.7 | G | |||||||||||||||
| 28 31 70 | SD-02 - Battery Power | 1.9.1.8 | G | |||||||||||||||
| 28 31 70 | SD-02 - Voltage Drop Calculations | 1.9.1.9 | G | |||||||||||||||
| 28 31 70 | SD-03 - Smoke Detectors | 2.7 | G | |||||||||||||||
| 28 31 70 | SD-03 - Air sampling smoke detectors | 3.2.6 | G | |||||||||||||||
| 28 31 70 | SD-03 - Addressable Interface Devices | 2.12 | G | |||||||||||||||
| 28 31 70 | SD-03 - Addressable Control Modules | 2.13 | G | |||||||||||||||
| 28 31 70 | SD-03 - Notification Appliances | 1.9.1.6 | G | |||||||||||||||
| 28 31 70 | SD-03 - Batteries | 2.17.1 | G | |||||||||||||||
| 28 31 70 | SD-03 - Battery Chargers | 2.17.2 | G | |||||||||||||||
| 28 31 70 | SD-03 - Supplemental Notification Appliance Circuit Panels | 2.17.1.1 | G | |||||||||||||||
| 28 31 70 | SD-03 - Auxiliary Power Supply Panels | 2.17.1.1 | G | |||||||||||||||
| 28 31 70 | SD-03 - Surge Protective Devices | 2.18 | G | |||||||||||||||
| 28 31 70 | SD-03 - Alarm Wiring | 2.18 | G | |||||||||||||||
| 28 31 70 | SD-03 - Back Boxes and Conduit | 3.3.4 | G | |||||||||||||||
| 28 31 70 | SD-03 - Ceiling Bridges | 3.2.11 | G | |||||||||||||||
| 28 31 70 | SD-03 - Terminal Cabinets | 3.3.2 | G | |||||||||||||||
| 28 31 70 | SD-03 - Radio Transmitter and Interface Panels | 2.12.1 | G | |||||||||||||||
| 28 31 70 | SD-03 - Electromagnetic Door Holders | 2.13.2 | G | |||||||||||||||
| 28 31 70 | SD-03 - Document Storage Cabinet | 3.12.3 | G | |||||||||||||||
| 28 31 70 | SD-05 - Air Sampling Smoke Detection System Calculations | 1.9.1.11 | G | |||||||||||||||
| 28 31 70 | SD-06 - Test Procedures | 3.8.1 | G | |||||||||||||||
| 28 31 70 | SD-07 - Verification of Compliant Installation | 3.8.2.1 | G | |||||||||||||||
| 28 31 70 | SD-07 - Request for Government Final Test | 3.8.2.2 | G | |||||||||||||||
| 28 31 70 | SD-10 - Operation and Maintenance (O&M) Instructions | 3.1 | G | |||||||||||||||
| 28 31 70 | SD-10 - Instruction of Government Employees | 3.11 | G | |||||||||||||||
| 28 31 70 | SD-11 - As-Built Drawings | 1.9.1.13 | ||||||||||||||||
| 28 31 70 | SD-11 - Spare Parts | 1.11.1 | ||||||||||||||||
| 31 23 00.00 20 | SD-06 - Borrow Site Testing | 1.6 | G | |||||||||||||||
| 31 23 00.00 20 | SD-06 - Fill and backfill | 3.17.2.1 | ||||||||||||||||
| 31 23 00.00 20 | SD-06 - Select material | 3.17.2.2 | ||||||||||||||||
| 31 23 00.00 20 | SD-06 - Density tests | 3.17.2.4 | ||||||||||||||||
| 31 23 00.00 20 | SD-06 - Porous fill | 3.11.2.3 | ||||||||||||||||
| 32 92 19 | SD-03 - Fertilizer | 2.4 | ||||||||||||||||
| 32 92 19 | SD-06 - Topsoil Composition Tests | 2.2.3 | ||||||||||||||||
| 32 92 19 | SD-07 - Seed | 2.1 |
Submittal Register, Dec 2019 Page &P of &N
File details come from the government source that posted it. Updated .