15.1021.07 - Updated Bid Drawings.pdf
PDF 20 MB Posted
- Solicitation number
- 36C25021B0019
About this file
This solicitation document describes a federal contract opportunity for expanding an emergency distribution panel board and adding cooling to a substation room at a VA medical center in Columbus, Ohio. The project magnitude is between $500,000 and $1,000,000, it uses NAICS code 238210 with a business size standard of $16.5 million, and is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses. Interested SDVOSBs must be registered and verified on SAM.gov, VIP.gov, and meet all set-aside eligibility requirements. The solicitation will be posted on March 22nd on SAM.gov with a bid opening approximately 30 days later. All work and communications will be electronic, with amendments posted to SAM.gov and registered offerors notified by email. Questions are due by the specified cutoff date and must be emailed to the contracting officer.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SAM Award Notice.pdf | ||
| AS101.pdf | ||
| SECTION 05 50 00 METAL FABRICATIONS.pdf | ||
| 36C25021B0019 0003.docx | DOCX document | |
| 36C25021B0019 0002.docx | DOCX document | |
| 36C25021B0019 0001.docx | DOCX document | |
| ED Russ Electric JA - APPROVED - Redacted.pdf | ||
| WD 07.30.2021 Franklin.pdf | ||
| VHA Directive 1013 Prevention and Control of Seasonal Influenza with Vaccines.pdf | ||
| ED Eaton JA -APPROVED - Redacted.pdf | ||
| 36C25021B0019_1.docx | DOCX document | |
| 757-20-101 Correct RCx_VAACC Health Requirements.pdf | ||
| 15.1021.07 - Updated Bid Specs.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ALTERNATE DEDUCT
#1 REMOVE NEW DOOR AT EXISTING SECOND-LEVEL STOREFRONT AND STEEL HANDRAIL:
REMOVE 3'-0'x7'-0" STOREFRONT DOOR AND ASSOCIATED, EXISTING STOREFRONT MODIFICATIONS
FOR ROOFTOP ACCESS FROM SCOPE. REMOVE STEEL HANDRAIL ON EXISTING CANOPY FROM
SCOPE.
#2 REMOVE AND REPLACE EXISTING BOLLARDS AND PLANTERS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
100% Construction Documents 6/1/20
95% Construction Documents 4/17/20
65% Design Development 11/27/19
35% Schematic Design 03/27/19
Bid Documents 8/19/20
C U s e rs
\m v a n d e rw o u d e \D o c u m e n ts \1
.1
V A
V
IS
N v m v a n d e rw o u d e
.r v t
/1
/2
:2
:5
P
M
GI000
COVER SHEET EXPAND EXISTING EMERGENCY
DISTRIBUTION PANEL BOARD & ADD
COOLING TO SUBSTATION ROOM
CHALMERS P. WYLIE VAACC
757-19-202
1A
3/5/2021 JF MAE
757-19-202
EXPAND EXISTING EMERGENCY DISTRIBUTION
PANEL BOARD & ADD COOLING TO
SUBSTATION ROOM
DEPARTMENT OF VETERANS AFFAIRS
CHALMERS P. WYLIE VAACC
BID DOCUMENTS
BID DOCUMENTS
FULLY SPRINKLERED
SHEET LIST
SHEET
NUMBER SHEET NAME
GENERAL
GI000 COVER SHEET
GI101 CODE ANALYSIS & LIFE SAFETY PLAN
STRUCTURAL
SI001 GENERAL NOTES
SB101 FOUNDATION AND FRAMING PLANS
SF501 FRAMING SECTIONS AND DETAILS
ARCHITECTURAL
AE001 ARCHITECTURAL SYMBOLS AND ABBREVIATIONS
AE002 DOOR AND WALL TYPE SCHEDULES
AS101 ARCHITECTURAL SITE PLAN
AE101 FIRST FLOOR PARTIAL DEMOLITION PLAN
AE102 FIRST FLOOR PARTIAL FLOOR PLAN
AE103 FIRST FLOOR PARTIAL ROOF AND REFLECTED CEILING PLAN
AE201 CANOPY ELEVATIONS
AE202 SCREENWALL ELEVATIONS AND DETAILS
AE301 CANOPY WALL SECTIONS
AE302 CANOPY DETAILS
MECHANICAL
H000 HVAC LEGENDS
H101 PARTIAL FIRST FLOOR HVAC PLAN
H500 HVAC SCHEDULES AND DETAILS
ELECTRICAL
E100 ELECTRICAL SCHEDULES AND DETAILS
E101 PARTIAL FIRST FLOOR ELECTRICAL PLAN
Contact:Contact: Contact:
DYNAMIX ENGINEERING
MECHANICAL, ELECTRICAL &
PLUMBING
Michael Spengler
Project Coordinator / Sr.
Mechanical Engineer
COLUMBUS VA AMBULATORY
CARE CENTER
Phil Bruno
Project COR
420 N. James Road Columbus, OH 43219 p: 614.257.5719 e: philip.bruno1@va.gov
OWNER
GUIDON DESIGN INC.
Mark VanderWoude
Sr. Project Manager / Engineer
1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202 p: 317.800.6388 x 119 e: mvanderwoude@guidondesign.com
CIVIL, STRUCTURAL
ENGINEER, AND ARCHITECT
855 Grandview Avenue Suite 300 Columbus, OH 43215 p: 614.433.1178 x 277 e: mspengler@dynamix-ltd.com
AREA MAP
VICINITY MAP
PROJECT SITE
PROJECT SITE
Revisions: Date:
TOTAL OCCUPANCY
FEC
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE
FIRE EXTINGUISHER CABINET
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE
EGRESS PATH
2 HR - FIRE SEPARATION
1 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
B
1500 SF
NPFA, NATIONAL FIRE PROTECTION ASSOCIATION FULL LISTING OF CURRENT CODES,
INCLUDING BUT NOT LIMITED TO:
NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHER
NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
NFPA 72 FIRE ALARM CODE
NFPA 70, NEC NATIONAL ELECTRICAL CODE
NFPA 80 STANDARD FOR FIRE DOORS AND FIRE WINDOWS
NFPA 88A STANDARD FOR PARKING STRUCTURES
NFPA 99 HEALTHCARE FACILITIES CODE
NPFA 101 LIFE SAFETY CODE
NFPA 220 STANDARD ON TYPES OF BUILDING CONSTRUCTION
NFPA 241 STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND
DEMOLITION OPERATIONS
ICC CODES, IINTERNATIONAL CODE COUNCIL FULL LISTING OF CURRENT CODES,
INCLUDING BUT NOT LIMITED TO:
INTERNATIONAL BUILDING CODE
INTERNATIONAL PLUMBING CODE
INTERNATIONAL MECHANICAL CODE
INTERNATIONAL FUEL GAS CODE
INTERNATIONAL FIRE CODE
INTERNATIONAL ENERGY AND CONSERVATION CODE
ASHRAE STANDARDS, AS REFERENCED WITHIN OTHER CODES INCLUDING, BUT NOT
LIMITED TO:
STANDARD 170-2017, VENTILATION OF HEALTHCARE FACILITIES
SSTANDARD 188-2018, LEGIONELLOSIS: RISK MANAGEMENT FOR BUILDING WATER
SYSTEMS
ACCESSIBILITY CODES
ADAAG, ADA ACCESSIBILITY GUIDELINES
VA BARRIER FREE DESIGN GUIDE PG-18-13, ABAAS
SYSTEMS RELATING TO MAINTENANCE OF FACILITIES
OSHA, OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION STANDARDS.
CODES AND GUIDELINES REFERENCED WITHIN NFPA AND ICC CODES ARE TO ALSO BE
FOLLOWED AND APPLIED TO ALL DESIGN AND CONSTRUCTION. REFER TO VA MANUAL
PG-18-3, SPECIFICATIONS FOR ADDITIONAL CODES, STANDARDS, GUIDELINES, AND
REGULATIONS. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTING WORK
COMPLIANT WITH OSHA, OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
STANDARDS.
VA Directives, Design Manuals, Master Specifications, VA National Cad Standard Application Guide,and other Guidance on the Technical Information Library (Til), www.cfm.va.gov/til/.
VA DESIGN GUIDES - https://www.cfm.va.gov/til/dGuide.asp ARCHITECTURAL - https://www.cfm.va.gov/til/dManual/dmARhosp.pdf ASBESTOS ABATEMENT - https://www.cfm.va.gov/til/dManual/dmASBhosp.pdf
CRITICAL PATH METHOD SCHEDULE & RISK MANAGEMENT FOR A/E
VOLUME 1- https://www.cfm.va.gov/til/dManual/dmCPM1.pdf VOLUME 2 - https://www.cfm.va.gov/til/dManual/dmCPM2.pdf ELECTRICAL - https://www.cfm.va.gov/til/dManual/dmElec.pdf ELEVATORS - https://www.cfm.va.gov/til/dManual/dmElev.pdf EQUIPMENT - https://www.cfm.va.gov/til/dManual/dmEQhosp.doc ESTIMATING - https://www.cfm.va.gov/til/dManual/dmCost.pd FIRE PROTECTION - https://www.cfm.va.gov/til/dManual/dmFire.pdf HVAC - https://www.cfm.va.gov/til/dManual/dmHVAC.pd INTERIOR DESIGN - https://www.cfm.va.gov/til/dManual/dmIDhonh.pdf LIGHTING DESIGN - https://www.cfm.va.gov/til/dManual/dmLighting.pdf
PHYSICAL SECURITY
LIFE SAFETY PROTECTED FACILITIES -
https://www.cfm.va.gov/til/PhysicalSecurity/dmPhySecLS.pdf MISSION CRITICAL FACILITIES - https://www.cfm.va.gov/til/PhysicalSecurity/dmPhySecMC.pdf APPENDIX Aa – https://www.cfm.va.gov/til/PhysicalSecurity/dmPhySecAppAa.xlsx APPENDIX Ab – https://www.cfm.va.gov/til/PhysicalSecurity/dmPhySecAppAb.pd APPENDIX Ac – https://www.cfm.va.gov/til/PhysicalSecurity/dmPhySecAppAc.pdf APPENDIX B – https://www.cfm.va.gov/til/PhysicalSecurity/dmPhySecAppB.xlsx PLUMBING - https://www.cfm.va.gov/til/dManual/dmPlbg.pdf SITE PARKING - https://www.cfm.va.gov/til/dManual/dmParking.pdf SITE DEVELOPMENT - https://www.cfm.va.gov/til/dManual/dmSITE.pdf SITE APPENDIX - https://www.cfm.va.gov/til/dManual/dmSITEAppendix.pdf
STEAM, HEATING, HOT WATER, AND OUTSIDE DISTRIBUTION SYSTEMS
VOLUME1 – https://www.cfm.va.gov/til/dManual/dmSm01.pdf VOLUME 2 – https://www.cfm.va.gov/til/dManual/dmSm02.pdf VOLUME 3 – https://www.cfm.va.gov/til/dManual/dmSm03.pdf
STRUCTURAL
A. ANCILLARY FACILITY - https://www.cfm.va.gov/til/dManual/dmSTaf.pdf B. ENERGY CENTER - https://www.cfm.va.gov/til/dManual/dmSTec.pdf C. MEDICAL UNIT - https://www.cfm.va.gov/til/dManual/dmSThosp.pdf D. NURSING HOME - https://www.cfm.va.gov/til/dManual/dmSTnhdb.pd E. PARKING STRUCTURE - https://www.cfm.va.gov/til/dManual/dmSTpark.pdf F. REGIONAL OFFICE - https://www.cfm.va.gov/til/dManual/dmSTro.pdf G. SEISMIC RETROFIT - https://www.cfm.va.gov/til/dManual/dmSTseis.pdf SUSTAINABILITY, https://www.cfm.va.gov/til/sustain/dmSustain.pdf TELECOMMUNICATIONS, https://www.cfm.va.gov/til/dManual/dmTelecomm.pdf
GOVERNING CODES
VA DESIGN MANUALS PG-18-10
CODE ANALYSIS LEGEND
NEW CANOPY AND EMERGENCY DISTRIBUTION
PANEL ACCESS (PROJECT SCOPE)
EXISTING 2-HR SEPARATION BETWEEN B-AMBULATORY CARE
AND HEALTHCARE OCCUPANCIES
B-AMBULATORY CARE OCCUPANCY HEALTHCARE OCCUPANCY
7.5
8.1
8.5
OUTLINE OF
NEW CANOPY
ABOVE
CORR
1A012
EMERGENCY
DISTRIBUTION
1A013
ELECTRICAL
1A360
Room
1A340
MECHANICAL
1A350
Room
1A351
Room
1A014
STAIRS
1S002 VESTIBULE
1A016Room
1A015
ELEV.
S1
Room
1B224
Room
1B223
CORR
1B004
Room
1A026
Room
1S003
CORR
1A017
Room
1A072
15' - 1 1/4" 5' - 0"
P R
O J E
C T
B O
U N
D A
R Y
PROJECT
BOUNDARY
EXIT 5'
LINE OF
EXISTING
CANOPY ABOVE
1'
/8
K J
CODE CRITERIA
GENERAL: THIS SUMMARY OF CODE REQUIREMENTS IS BASED PRIMARILY ON NFPA 101 (LSC). DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE IDENTIFIED. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC
HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES.
NOTES:
CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
CODE REVIEW
THE 2015 EDITION OF THE LIFE SAFETY CODE, NFPA 101, HAS BEEN USED TO REVIEW THIS PROJECT FOR COMPLIANCE WITH THE FIRE AND LIFE SAFETY REQUIREMENTS. FOR FEATURES NOT ADDRESSED BY NFPA 101 AND THE REFERENCED NATIONAL FIRE CODES, THE 2015 EDITION OF THE INTERNATIONAL BUILDING CODE HAS BEEN USED.
PROJECT SCOPE
THE NEW CANOPY WILL ATTACH TO THE EAST WALL AND NORTH ENTRY SIDE OF THE EXISTING BUILDING. A NEW, EXTERIOR METAL CLADDING SYSTEM WILL BE USED TO MATCH THE EXISTING CLADDING OF THE BUILDING. A SCREENWALL BE INSTALLED TO CONCEAL THE NEW MECHANICAL EQUIPMENT THAT WILL BE PLACED ON TOP OF THE CANOPY ROOF. ADJUSTMENTS TO THE EXISTING STRUCTURE WILL BE MADE, AS REQUIRED, TO MAKE THE ATTACHMENTS. CHANGES TO THE EXISTING DOORS TO BE MADE, AS NEEDED TO MAINTAIN EGRESS PATHS.
THE CONSTRUCTION TYPE IS DETERMINED BASED UPON THE ALLOWABLE AREA AND HEIGHT REQUIREMENTS OF CHAPTER 5 OF THE 2015 IBC. CONSTRUCTION TYPE AND
MATERIALS SHALL BE PER CHAPTER 6 OF THE IBC FOR TYPE II-A.
1. OCCUPANCY TYPE: B - AMBULATORY CARE, IBC CHAPTER 3/LSC CHAPTER 22
2. CONSTRUCTION TYPE: IIA (IBC CHAPTER 5)
3. FIRE RESISTIVE RATINGS TYPE IIA CONSTRUCTION, CHAPTER 6 IBC/NFPA 101:
STRUCTURAL FRAME: NONCOMBUSTIBLE, 1-HOUR FIRE RESISTIVE
BEARING WALLS
EXTERIOR: NONCOMBUSTIBLE, 1-HOUR FIRE RESISTIVE
INTERIOR: NONCOMBUSTIBLE, 1-HOUR FIRE RESISTIVE
NON-BEARING WALLS AND PARTITIONS
EXTERIOR:
<30' SEPARATION NONCOMBUSTIBLE, 1-HOUR FIRE RESISTIVE
>30' SEPARATION NONCOMBUSTIBLE, 0-HOUR FIRE RESISTIVE
INTERIOR: NONCOMBUSTIBLE, 1-HOUR FIRE-RESISTIVE
FLOOR: NONCOMBUSTIBLE, 0-HOUR FIRE RESISTIVE
ROOF: NONCOMBUSTIBLE, 1-HOUR FIRE RESISTIVE
4. STRUCTURAL DESIGN SHALL COMPLY WITH CHAPTER 16 OF THE IBC.
5. ALLOWABLE HEIGHT: 65 FT (IBC, TABLE 504.3)
6. ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLAN: 5 (IBC, TABLE 504.4)
7. ALLOWABLE AREA: BASED UPON B-AMBULATORY CARE OCCUPANCY, II-A CONSTRUCTION TYPE, AND NOT SPRINKLED: ALLOWABLE AREA: 37,500 (IBC, TABLE 506.2)
8. BUILDING SEPARATION: BASED ON A 30' FIRE SEPARATION DISTANCE A 0 -HOUR FIRE RESISTANCE WALL RATING IS REQUIRED. (IBC, TABLE 602)
9. MEANS OF EGRESS
• CLEAR WIDTH OF CORRIDORS SHALL BE CLEAR 44 INCHES.
• CLEAR WIDTH OF DOORS SHALL BE CLEAR 32 INCHES
• NOT LESS THAN 2 EXITS SHALL BE PROVIDED PER FLOOR.
• MAXIMUM TRAVEL DISTANCE, FULLY SPRINKLED: 200 FEET (LSC 20.2.6.1)
• COMMON PATH OF TRAVEL SHALL NOT EXCEED 100 FEET (LSC 38.2.5.3.1)
• DEAD END CORRIDORS SHALL NOT EXCEED 50 FEET. (LSC 38.2.5.2.1)
• MEANS OF EGRESS SHALL BE ILLUMINATED PER 7.9. (LSC 20.2.8.2.8)
• EXIT SIGNAGE SHALL BE PROVIDED. (LSC 38.2.10)
10. INTERIOR FINISH
• WALLS AND CEILINGS: INTERIOR FINISH FLAME SPREAD SHALL BE LIMITED PER CHAPTER 8 OF THE NFPA 101 TO CLASS A, B AND C MATERIALS. INTERIOR WALL AND
CEILING FINISH SHALL BE CLASS A OR CLASS B IN EXITS, CORRIDORS AND LOBBIES; AND CLASS A, CLASS B, OR CLASS C IN ALL OTHER AREAS. (LSC 38.3.3)
• · CLASS A: FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450.
• · CLASS B: FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450.
• · CLASS C: FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450
11. CONSTRUCTION BARRIERS CONSTRUCTED ALONG MEANS OF EGRESS SHALL BE CONSTRUCTED AND MAINTAINED PER NFPA 241.
CODE ANALYSIS - NFPA 101, AMBULARTORY CARE CHAPTER 22
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
100% Construction Documents 6/1/20
95% Construction Documents 4/17/20
65% Design Development 11/27/19
35% Schematic Design 03/27/19
Bid Documents 8/19/20
C U s e rs
\m v a n d e rw o u d e \D o c u m e n ts \1
.1
V A
V
IS
N v m v a n d e rw o u d e
.r v t
/1
/2
:2
:0
P
M
GI101
CODE ANALYSIS & LIFE SAFETY
PLAN
EXPAND EXISTING EMERGENCY
DISTRIBUTION PANEL BOARD & ADD
COOLING TO SUBSTATION ROOM
CHALMERS P. WYLIE VAACC
757-19-202
1A
3/5/2021 JF MAE
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/64" = 1'-0"GI101
3 OVERALL LIFE SAFETY PLAN
SCALE: 1/8" = 1'-0"GI101
4 FIRST FLOOR PLAN - LIFE SAFETY ADDITION AND RENOVATION
N N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs
\m v a n d e rw o u d e \D o c u m e n ts \1
.1
.0
E le c tr ic P a n e l V m v a n d e rw o u d e
.r v t
/1
/2
:1
:0
P
M
SI001
GENERAL NOTES EXPAND EXISTING EMERGENCY
DISTRIBUTION PANEL BOARD & ADD
COOLING TO SUBSTATION ROOM
CHALMERS P. WYLIE VAACC
757-19-202
1A
3/5/2021 MAV ADK
BID DOCUMENTS
FULLY SPRINKLERED
GENERAL
THE STRUCTURE HAS BEEN DESIGNED FOR THE IN-SERVICE LOADS ONLY. THE METHODS, MEANS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF
NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, TIEDOWNS, ETC.
THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING
DRAWINGS AND SPECIFICATIONS.
THE GENERAL NOTES ON THE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE FULL WRITTEN MATERIAL SPECIFICATIONS (IF ANY) FOR THE PROJECT. IF A DISCREPANCY OCCURS BETWEEN THE NOTES AND THE FULL SPECIFICATIONS, THE MORE STRINGENT
REQUIREMENT SHALL APPLY.
NO PENETRATIONS THROUGH STRUCTURAL ELEMENTS, OTHER THAN THOSE SHOWN ON THE DRAWINGS, SHALL BE MADE WITHOUT
THE APPROVAL OF THE STRUCTURAL ENGINEER.
CONTRACTOR TO COORDINATE ALL EQUIPMENT, ROOF DRAINS, CHASES, AND OTHER ITEMS CONNECTED TO THE STRUCTURE BEFORE
FABRICATION BEGINS.
CONCRETE MIX DESIGN SUBMITTAL
THE CONTRACTOR SHALL SUBMIT FOR THE REVIEW OF THE STRUCTURAL ENGINEER A MIX DESIGN FOR EACH PROPOSED CLASS OF CONCRETE. EACH MIX DESIGN SHALL BE IDENTIFIED BY A MIX NUMBER OR OTHER UNIQUE IDENTIFICATION. THE CONTRACTOR SHALL NOT VARY FROM THE MIX DESIGNS NOR USE ANY CONCRETEOTHER THAN THE APPROVED MIX DESIGNS WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. MIX DESIGN SUBMITTALS SHALL INCLUDE THE FOLLOWING INFORMATION:
1. MIX DESIGN NUMBER OR UNIQUE IDENTIFICATION AND INTENDED LOCATION OF PLACEMENT.
2. CEMENT TYPE, PROPORTION AND NAME OF MANUFACTURER.
3. FLY ASH PROPORTION (WHEN USED), LABORATORY ANALYSIS CERTIFICATION, AND NAME AND LOCATION OF SUPPLIER.
4. COURSE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER.
5. FINE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER.
6. MIXING WATER PROPORTION AND SOURCE.
7. ADMIXTURE DOSAGES, PRODUCT NAME(S) AND MANUFACTURER NAME(S).
8. FIBER REINFORCEMENT DOSAGE (WHEN USED), PRODUCT NAME AND MANUFACTURER NAME.
9. DESIGN 28-DAY COMPRESSIVE STRENGTH (F'C).
10. DESIGN SLUMP RANGE.
11. DESIGN AIR-ENTRAINMENT (FOR CONCRETE REQUIRING ENTRAINED AIR).
12. STATISTICAL ANALYSIS OF LABORATORY STRENGTH TEST DATA IN ACCORDANCE WITH "STANDARD DEVIATION"
DETERMINATION OUTLINED IN ACI 318.
SHOP DRAWING SUBMITTALS
THE CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS TO ENABLE HIM TO FABRICATE, ERECT AND CONSTRUCT ALL PARTS OF THE WORK IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS. THESE SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT ONLY. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS, ACCURACY AND FIT OF WORK.
ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE STRUCTURAL ENGINEER. DRAWINGS
SUBMITTED WITHOUT CONTRACTOR'S REVIEW WILL BE RETURNED UNCHECKED.
SUBMIT ELECTRONIC VERSIONS OF SHOP DRAWINGS. SUBMIT SHOP DRAWINGS IN PDF FORMAT.
SUBMIT SHOP DRAWINGS FOR EACH OF THE FOLLOWING ITEMS:
1. STRUCTURAL STEEL (INCLUDING DESIGN CALCULATIONS SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS CONSTRUCTED FOR ALL CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DRAWINGS)
2. STEEL DECK
PRODUCT DATA SUBMITTALS
THE CONTRACTOR SHALL SUBMIT FOR APPROVAL PRODUCT DATA FOR THE SPECIFIC ITEMS LISTED BELOW. CONTRACTOR SHALL NOT USE PRODUCTS OTHER THAN THOSE SUBMITTED WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER.
MANUFACTURER'S TRADE NAMES AND NUMBERS USED HEREIN ARE ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES, AND PATTERNS AS A BASIS OF DESIGN. PRODUCTS OF AUTHORIZED EQUAL MANUFACTURER'S EQUIVALENT TO COLORS, FINISHES, TEXTURES, AND PATTERNS OF MANUFACTURERS LISTED THAT MEET REQUIREMENTS OF TECHNICAL SPECIFICATIONS IN EVERY RESPECT MAY BE ACCEPTABLE WITH SUBMITTAL OF A COMPLETED SUBSTITUTION REQUEST CONTAINING ALL PRODUCT DATA, TESTING AND ACTUAL
SAMPLES, AND UPON APPROVAL IN WRITING BY CONTRACTING OFFICER.
SUBMIT ELECTRONIC VERSIONS OF PRODUCT DATA IN PDF FORMAT TO THE STRUCTURAL ENGINEER AND COR FOR REVIEW.
1. FIBER REINFORCEMENT FOR CONCRETE
2. CONCRETE REINFORCEMENT
3. CONCRETE CURING COMPOUND
4. CONCRETE JOINT SEALANT
5. WATER STOPS
6. EXPANSION ANCHORS
7. ADHESIVE ANCHORS
8. NON-SHRINK GROUT
FOUNDATIONS
FOUNDATIONS HAVE BEEN DESIGNED BASED ON ASSUMED ALLOWABLE CAPACITIES OF 2500 PSF. CONTRACTOR SHALL ENGAGE A LICENSED GEOTECHNICAL ENGINEER TO REVIEW THE SOIL CONDITIONS AT THE SITE AS NECESSARY TO CONFIRM THE ALLOWABLE CAPACITIES PRIOR TO PLACEMENT OF THE FOUNDATIONS. CONFIRMATION OF THE ACCEPTABILITY OF THE SOILS SHALL BE REPORTED
IN WRITING TO THE STRUCTURAL ENGINEER.
IF ACTUAL ALLOWABLE CAPACITIES ARE FOUND TO BE LESS THAN THE ASSUMED VALUES, THE CONTRACTOR SHALL NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY AND SHALL NOT PROCEED WITH FOUNDATION CONSTRUCTION WITHOUT REVIEW BY THE
STRUCTURAL ENGINEER.
FOUNDATIONS AND SOILS RELATED WORK SHALL BE INSPECTED BY A LICENSED GEOTECHNICAL ENGINEER. WRITTEN FIELD REPORTS
SHALL BE FORWARDED TO THE STRUCTURAL ENGINEER AS SOON AS THEY BECOME AVAILABLE.
FOUNDATION CONDITIONS NOTED DURING CONSTRUCTION, WHICH DIFFER FROM THOSE DESCRIBED IN THE GEOTECHNICAL REPORT, SHALL BE REPORTED TO THE STRUCTURAL ENGINEER AND GEOTECHNICAL ENGINEER BEFORE FURTHER CONSTRUCTION IS
ATTEMPTED.
EXCAVATIONS FOR SPREAD FOOTINGS, COMBINED FOOTINGS, CONTINUOUS FOOTINGS AND MAT FOUNDATIONS SHALL BE CLEANED AND HAND TAMPED TO UNIFORM SURFACE AND SHALL BE PROTECTED AND MAINTAINED UNIFORM UNTIL CONCRETE IS PLACED.
CONCRETE
REINFORCED CONCRETE HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE (ACI 318) AND COMMENTARY (ACI 318R).
MIXING, TRANSPORTING, AND PLACING OF CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301). READY-MIXED CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ASTM C94. IN CASE OF A
DISCREPANCY, THE PLANS AND SPECIFICATIONS SHALL GOVERN.
CEMENT SHALL CONFORM TO ASTM C150, TYPE I, UNO.
FLY ASH SHALL CONFORM TO ASTM C618, CLASS C OR F. THE RATIO OF THE AMOUNT (BY WEIGHT) OF FLY ASH TO TOTAL
CEMENTITIOUS MATERIALS IN THE MIX SHALL NOT EXCEED 25 PERCENT.
NORMAL WEIGHT AGGREGATES SHALL CONFORM TO ASTM C33.
WATER-REDUCING ADMIXTURES SHALL CONFORM TO ASTM C494.
AIR-ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C260 AND SHALL BE CERTIFIED BY THE MANUFACTURER TO BE COMPATIBLE
WITH OTHER ADMIXTURES.
CALCIUM CHLORIDE ADMIXTURES OR ADMIXTURES CONTAINING MORE THAN 0.1 PERCENT CHLORIDE IONS SHALL NOT BE USED.
IN COLD WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND PROTECTION OF CONCRETE SHALL BE PERFORMED IN
ACCORDANCE WITH THE LATEST EDITION OF ACI 306R, COLD WEATHER CONCRETING.
IN HOT WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND PROTECTION OF CONCRETE SHALL BE PERFORMED IN
ACCORDANCE WITH THE LATEST EDITION OF ACI 305R, HOT WEATHER CONCRETING.
USE OF CONSTRUCTION JOINTS AT LOCATIONS OTHER THAN THOSE INDICATED ON THE DRAWINGS SHALL BE SUBMITTED TO THE
STRUCTURAL ENGINEER FOR REVIEW.
SLUMP FOR PUMPED CONCRETE SHALL BE MEASURED AT POINT OF DISCHARGE.
NORMAL WEIGHT CONCRETE SHALL BE USED IN THE FOLLOWING AREAS AND SHALL
HAVE THE PROPERTIES AS SHOWN BELOW:
FOUNDATIONS
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 470 LB./CU. YD. (USE TYPE II SULFATE RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8 INCHES (AFTER ADMIXTURE IS
ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.48
6. MAXIMUM COARSE AGGREGATE SIZE: 1 1/2 INCHES
7. AIR CONTENT: N/A
RETAINING WALLS AND CURBS/SIDEWALKS/SLABS EXPOSED TO DE-ICERS
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 517 LB./CU. YD. (USE TYPE II SULFATE RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8 INCHES (AFTER ADMIXTURE IS
ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.45
6. MAXIMUM COARSE AGGREGATE SIZE: 1 INCH
7. AIR CONTENT: 6.0% +/- 1%
REINFORCING STEEL
REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 AND SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000
PSI.
REINFORCING BAR DETAILING, FABRICATING, AND PLACING SHALL CONFORM TO THE LATEST EDITION OF THE FOLLOWING STANDARDS:
ACI 301, ACI 315, ACI 318 AND ACI DETAILING MANUAL (SP66).
UNLESS A GREATER AMOUNT OF COVER IS INDICATED ON THE DRAWINGS, PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER
OVER REINFORCEMENT AS FOLLOWS:
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3 INCHES
#6 BARS AND LARGER EXPOSED TO EARTH OR WEATHER: 2 INCHES
#5 BARS AND SMALLER EXPOSED TO EARTH OR WEATHER: 1-1/2 INCHES
BEAM AND COLUMN TIES, STIRRUPS AND SPIRALS: 1-1/2 INCHES
ELEVATED SLAB BARS NOT EXPOSED TO EARTH OR WEATHER: 3/4 INCH
REINFORCING STEEL SHALL NOT BE TACK WELDED, WELDED, HEATED OR CUT UNLESS INDICATED ON THE CONTRACT DOCUMENTS OR
APPROVED BY THE STRUCTURAL ENGINEER.
WHERE LAP SPLICE LENGTHS ARE NOT SHOWN OR NOTED, PROVIDE A CLASS "B" LAP.
ALL 90 DEGREE AND 180 DEGREE BENDS SHOWN ON THE DRAWINGS SHALL BE STANDARD HOOKS, UNLESS NOTED OTHERWISE.
PROVIDE CORNER BARS OF SAME SIZE AND SPACING AS HORIZONTAL BARS AT CORNERS OF ALL WALLS AND GRADE BEAMS. LAP
SPLICE CORNER BARS WITH STRAIGHT BARS.
UNLESS OTHERWISE SHOWN OR NOTED, PROVIDE 2-#5 BARS (ONE EACH FACE) AROUND UNFRAMED OPENINGS IN CONCRETE WALLS AND GRADE BEAMS. PLACE BARS PARALLEL TO THE SIDES OF THE OPENING AND EXTEND 24" BEYOND CORNERS.
EPOXY-COATED REINFORCING STEEL
EPOXY COATED REINFORCING STEEL SHALL CONFORM TO ASTM A775 AND SHALL BE USED ONLY WHERE SHOWN OR NOTED ON THE
DRAWINGS.
CONCRETE TESTING
MAKE ONE SET OF TEST CYLINDERS IN ACCORDANCE WITH ASTM C31 FOR EACH DAY'S POUR AND FOR EACH 100 CUBIC YARDS. EACH SET SHALL INCLUDE ONE SPECIMEN TESTED AT 7 DAYS, 2 SPECIMENS TESTED AT 28 DAYS AND ONE SPECIMEN RETAINED IN RESERVE TO BE TESTED AT THE DIRECTION OF THE STRUCTURAL ENGINEER. SPARE CYLINDER MAY BE DISCARDED 90 DAYS AFTER CASTING
UNLESS
DIRECTED OTHERWISE BY THE STRUCTURAL ENGINEER. THIS SET OF TEST CYLINDERS SHALL BE PROTECTED AGAINST FREEZING.
WHEN THE AMBIENT TEMPERATURE IS EXPECTED TO FALL BELOW 40 DEGREES DURING THE COURSE OF A CONCRETE POUR OR SUBSEQUENT CURING PROCESS, AN ADDITIONAL SET OF CONCRETE TEST CYLINDERS SHALL BE MADE AND TESTED. THESE CYLINDERS SHALL BE STORED IMMEDIATELY ADJACENT TO, AND CURED UNDER THE SAME CONDITIONS AS THE BUILDING CONCRETE. SPECIAL
CURING BOXES ARE NOT PERMITTED FOR THESE TEST CYLINDERS.
FORWARD COPIES OF TEST RESULTS TO THE ARCHITECT, STRUCTURAL ENGINEER, READY-MIX SUPPLIER AND CONTRACTOR WITHIN 24
HOURS AFTER TESTING.
NON-SHRINK GROUT
GROUT SHALL BE A NON-METALLIC, SHRINKAGE RESISTANT (WHEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ASTM C827 OR CRD-C621), PREMIXED, NON-CORROSIVE, NON-STAINING PRODUCT CONTAINING PORTLAND CEMENT, SILICA SANDS, SHRINKAGE COMPENSATING AGENTS AND FLUIDITY IMPROVING COMPOUNDS. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (F'C) OF
5,000 PSI IN 28 DAYS.
WATERSTOPS
SELF-EXPANDING STRIP WATER STOPS SHALL BE VOLCLAY WATERSTOP-RX 101 UNLESS NOTED OTHERWISE. INSTALL IN ACCORDANCE
WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
PVC WATERSTOPS
PROVIDE FACTORY MADE WATERSTOP FABRICATIONS FOR ALL CHANGES OF DIRECTION, INTERSECTIONS, AND TRANSITIONS LEAVING
ONLY STRAIGHT BUTT JOINT SPLICES FOR THE FIELD.
PROVIDE HOG RINGS OR GROMMETS SPACED AT 12 INCHES ON CENTER ALONG LENGTH OF WATERSTOP.
PROVIDE TEFLON COATED THERMOSTATICALLY CONTROLLED WATERSTOP SPLICING IRONS FOR FIELD BUTT SPLICES.
FIELD BUTT SPLICES SHALL BE HEAT FUSED WELDED USING A TEFLON COATED THERMOSTATICALLY CONTROLLED WATERSTOP SPLICING IRON AT APPROXIMATELY 380 DEGREES F. FOLLOW APPROVED MANUFACTURER RECOMMENDATIONS.
LAPPING OF WATERSTOP, USE OF ADHESIVES, OR SOLVENTS SHALL NOT BE ALLOWED.
CENTER WATERSTOP IN JOINT AND SECURE WATERSTOP IN CORRECT POSITION USING HOG RINGS OR GROMMETS SPACED AT 12 INCHES ON CENTER ALONG THE LENGTH OF THE WATERSTOP AND WIRE TIE TO ADJACENT REINFORCING STEEL.
STRUCTURAL STEEL
STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE ANSI/AISC 360 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, LATEST EDITION WITH AMENDMENTS, AND THE AISC 303 CODE OF STANDARD PRACTICE FOR
STEEL BUILDINGS AND BRIDGES, LATEST EDITION WITH AMENDMENTS.
STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, 50 KSI.
STRUCTURAL STEEL PLATES AND ROLLED SHAPES OTHER THAN WIDE-FLANGE SHAPES SHALL CONFORM TO ASTM A36, UNLESS NOTED
OTHERWISE.
STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500, GRADE B.
BOLTED CONNECTIONS SHALL CONFORM TO THE SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS, APPROVED BY THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS OF THE ENGINEERING FOUNDATION. BOLTED CONNECTIONS FOR STRUCTURAL STEEL MEMBERS SHALL BE MADE WITH 3/4" DIAMETER A325 BOLTS, UNLESS NOTED OTHERWISE.
BOLTED CONNECTIONS SHALL BE TIGHTENED TO THE SNUG TIGHT CONDITION, EXCEPT BOLTED CONNECTIONS IN BRACE ELEMENTS
ARE TO BE FULLY PRETENSIONED WITH CLASS A FAYING SURFACES.
WELDING PROCEDURES SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN WELDING SOCIETY'S STRUCTURAL WELDING
CODE FOR STEEL ANSI/AWS D1.1.
WELDED CONNECTIONS USING ASTM A992 STEEL AS A BASE METAL SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES.
UNLESS OTHERWISE SHOWN OR NOTED ON THE DRAWINGS, OTHER WELDED CONNECTIONS MAY BE MADE WITH STANDARD E70XX
ELECTRODES.
STRUCTURAL STEEL THAT RECEIVES FINISH PAINT SHALL BE SHOP-PRIMED WITH A RUST-INHIBITING PRIMER, UNLESS NOTED OTHERWISE ON THE DRAWINGS. CONTRACTOR SHALL VERIFY PRIMER IS COMPATIBLE WITH FINISH COAT SYSTEM SPECIFIED BY THE
ARCHITECT. COORDINATE FINISH PAINTING REQUIREMENTS WITH THE ARCHITECT.
STRUCTURAL STEEL THAT IS NOT EXPOSED IN THE FINISHED CONSTRUCTION AND DOES NOT RECEIVE FINISH PAINT SHALL NOT BE
SHOP-PRIMED, UNLESS NOTED OTHERWISE ON THE DRAWINGS.
ALL STRUCTURAL STEEL SHALL BE HOT-DIP GALVANIZED IN CONFORMANCE WITH ASTM A123.
DO NOT PAINT OR GALVANIZE THE FOLLOWING SURFACES:
1. SURFACES TO BE WELDED.
2. SURFACES TO RECEIVE BOLTED SLIP-CRITICAL CONNECTIONS.
3. SURFACES TO RECEIVE SHEAR STUD CONNECTIONS.
4. SURFACES TO RECEIVE SPRAYED-ON FIREPROOFING.
ALL ABRASIONS TO GALVANIZED SURFACES OR SURFACES TO RECEIVE AN ARCHITECTURAL FINISH COAT SHALL BE TOUCHED-UP AFTER ERECTION IS COMPLETE. FOR PAINTED STEEL, USE A PRIMER EQUIVALENT TO THE SHOP PAINT. FOR GALVANIZED STEEL, USE
A ZINC-RICH COLD-GALVANIZING PAINT.
DESIGN CONNECTIONS NOT SHOWN IN ACCORDANCE WITH THE ASD SPECIFICATION AND MANUAL OF STEEL CONSTRUCTION. UNLESS NOTED OTHERWISE ON THE DRAWINGS, DESIGN BEAM CONNECTIONS NOT SHOWN, TO SUPPORT A MINIMUM OF A 10 KIP SHEAR REACTION. PROVIDE NO LESS THAN 2 BOLTS IN ANY SINGLE LINE OF BOLTS, UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS.
PROVIDE L4X4X1/4 FRAMED OPENINGS FOR ALL ROOF PENETRATIONS 12 INCHES OR LARGER ALONG ANY SIDE, UNLESS LARGER FRAMING IS INDICATED. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR PENETRATIONS. COORDINATE FRAMED OPENING SIZES
AND LOCATIONS WITH THE MECHANICAL AND PLUMBING CONTRACTORS.
STEEL ROOF DECK
PROVIDE AND ERECT STEEL DECK IN ACCORDANCE WITH THE LATEST EDITION OF THE STEEL DECK INSTITUTE'S SPECIFICATIONS AND
CODE OF STANDARD PRACTICE.
DECK MANUFACTURER SHALL PROVIDE ALL ROOF DECK ACCESSORIES, INCLUDING CLOSURES, SUPPLEMENTARY FRAMING, AND SUMP
PANS, WHETHER OR NOT SUCH ITEMS ARE DETAILED ON THE CONTRACT DOCUMENTS.
FASTEN ROOF DECK TO STEEL SUPPORTS AS INDICATED ON THE DRAWINGS. PERFORM WELDING IN ACCORDANCE WITH ANSI/AWS D1.3.
ROOF DECK SHALL BE INSTALLED IN A MINIMUM THREE SPAN CONDITION.
PROVIDE STEEL ROOF DECK WITH FINISH AS INDICATED ON THE DRAWINGS.
DESIGN DATA
THE BUILDING STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE 2018 INTERNATIONAL BUILDING CODE.
DEAD LOAD: 10 PSF
LIVE LOAD: 20 PSF
MECHANICAL UNIT LOAD: 66 PSF
SNOW LOAD DESIGN DATA
1. GROUND SNOW LOAD (PG) = 20 PSF
2. MINIMUM APPLIED SNOW LOWAD = 20 PSF
3. SNOW EXPOSURE FACTOR (CE) = 1.0
4. THERMAL FACTOR (CT) = 1.2
5. SNOW LOAD IMPORTANCE FACTOR (IS) = .8
6. DRIFT LOAD: 47 PSF AT FACE OF BUILDING DRIFTING OVER 8 FT TO BASE SNOW LOAD
WIND LOAD DESIGN DATA
1. BASIC WIND SPEED (3-SECOND GUST) = 115 MPH
2. WIND LOAD IMPORTANCE FACTOR (IW) = 0.8
3. WIND EXPOSURE = B
4. WIND DESIGN PRESSURE (P) = 57 PLF ALONG SOFFIT
EARTHQUAKE DESIGN DATA
1. SHORT PERIOD SPECTRAL RESPONSE (SS) = 0.177
2. 1-SECOND SPECTRAL RESPONSE (S1) = 0.061
3. SEISMIC IMPORTANCE FACTOR (IE) = 1.0
4. OCCUPANCY CATEGORY = IV
5. SEISMIC DESIGN CATEGORY = B
6. SITE CLASSIFICATION = D
7. SHORT PERIOD SPECTRAL RESPONSE COEFFICIENT (SDS) = 0.189
8. 1-SECOND SPECTRAL RESPONSE COEFFICIENT (SD1) = 0.098
9. BASIC STRUCTURAL SYSTEM / SEISMIC RESISTING SYSTEM: H - STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC
RESISTANCE, EXCLUDING CANTILEVER COLUMN SYSTEMS
10. ANALYSIS PROCEDURE UTILIZED = EQUIVALENT LATERAL FORCE PROCEDURE
11. RESPONSE MODIFICATION COEFFICIENT (R) = 3.0
DESCRIPTION
F'C
PSI,
MIX
MAXIMUM
CHLORIDE
ION
CONTENT
MAX
W/C
RATIO
AVERAGE
ENTRAINED
AIR
MINIMUM
CEMENTITIOUS
MATERIALS
CONTENT,
LB/CYD
MAXIMUM
SLUMP
MAXIMUM SLUMP FOR
CONCRETE CONTAINING
HIGH-RANGE WATER-
REDUCING
ADMIXTURE
MAXIMUM
COARSE
AGGREGATE
SIZE
FOUNDATIONS &
PILE CAPS
4000 STD 0.30% 0.48 N/A 470 4" 8" AAC 1.5"
RETAINING WALLS &
CURBS/SIDEWALKS/SLABS
EXPOSED TO DE-ICERS
4000 CNA 0.15% 0.45 6% +/- 1% 517 4" 8" AAC 1"
NOTES:
1. "STD" INDICATES A CONCRETE MIX DESIGN IN ACCORDANCE WITH SPECIFICATION WHICH DOES NOT REQUIRE A SILICA FUME, GGBS/FLY ASH OR
CALCIUM NITRITE ADMIXTURE.
2. "CNA" INDICATES A CONCRETE MIX DESIGN IN ACCORDANCE WITH SPECIFICATION WHICH CONTAINS 3 GAL/CYD OF CALCIUM NITRITE CORROSION-
INHIBITOR ADMIXTURE.
3. "SF" INDICATES A CONCRETE MIX DESIGN WITH 1.5 LBS STRUCTURAL FIBERS PER CYD OF CONCRETE.
4. "AAC" MEANS SLUMP IS AFTER ADMIXTURE IS ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP.
RENOVATION (EXISTING CONDITIONS)
INFORMATION SHOWN FOR THE EXISTING STRUCTURE ON THESE DRAWINGS WAS TAKEN FROM DRAWINGS THAT WERE PREPARED FOR
THE VETERANS AFFAIRS DEPARTMENT
WORK SHOWN ON THESE PLANS ASSUMES THAT THE ORIGINAL CONSTRUCTION WAS PERFORMED IN ACCORDANCE WITH THE ABOVE INDICATED ORIGINAL DRAWINGS INCLUDING (BUT NOT LIMITED TO) DIMENSIONS, ELEVATIONS, MEMBER SIZES, MATERIALS, DETAILS, ETC. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE CONDITIONS RELATING TO THE EXISTING STRUCTURE AND TO
NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY OF ANY DISCREPANCIES OR CONFLICTS.
WHERE NEW WORK IS TO BE FITTED TO OLD WORK, THE CONTRACTOR SHALL CHECK ALL DIMENSIONS AND CONDITIONS IN THE FIELD, AND REPORT ANY ERRORS OR DISCREPANCIES TO THE STRUCTURAL ENGINEER PRIOR TO THE FABRICATION AND ERECTION OF ANY
NEW MEMBERS.
EXISTING MATERIALS TO BE REMOVED AND REINSTALLED AS PART OF THE PROJECT, THAT BECOME DAMAGED, SHALL BE REPLACED
WITH NEW MATERIAL OF EQUAL QUALITY AND APPEARANCE, AT THE CONTRACTORS EXPENSE.
ALL WORK SHALL BE PREFORMED WITHOUT DAMAGE TO ADJACENT RETAINED WORK. ADJACENT EXISTING CONSTRUCTION SHALL BE
PROTECTED FROM DUST, DIRT, AND DEBRIS ACCUMULATION AT ALL TIMES.
CONCRETE SLABS ON GRADE
SLABS ON GRADE SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE GUIDE FOR CONCRETE FLOOR AND
SLAB CONSTRUCTION (ACI 302.1R).
PLACE CONCRETE IN A MANNER SO AS TO PREVENT SEGREGATION OF THE MIX. DELAY FLOATING AND TROWELING OPERATIONS UNTIL THE CONCRETE HAS LOST SURFACE WATER SHEEN OR ALL FREE WATER. DO NOT SPRINKLE FREE CEMENT ON THE SLAB SURFACE.
PROVIDE CURING OF CONCRETE SLABS IMMEDIATELY AFTER FINISHING USING A SPRAYED ON DISSIPATING-RESIN LIQUID CURING COMPOUND CONFORMING TO ASTM C309, UNLESS NOTED OTHERWISE. ALL SCUFFS OR ABRASIONS TO THE CURING MEMBRANE SHALL BE RECOATED DAILY. OTHER CURING METHODS MAY BE USED WITH APPROVAL BY THE STRUCTURAL ENGINEER.
SLABS ON GRADE SHALL BE PLACED TO ACHIEVE THE FOLLOWING MINIMUM TOLERANCES:
OVERALL VALUES: FF = 25
LOCAL VALUES: FF = 20
THE MINIMUM LOCAL AREA SHALL BE ANY BAY DEFINED BY COLUMN LINES.
UNLESS SHOWN OR NOTED OTHERWISE, PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLABS-ON-GRADE AT A MAXIMUM SPACING OF 36 TIMES THE SLAB THICKNESS. PROVIDE JOINTS AT ALL COLUMN LOCATIONS. LOCATE JOINTS TO ELIMINATE RE-ENTRANT CORNERS AND TO CREATE SQUARE OR RECTANGULAR SECTIONS WITH MAXIMUM LONG SIDE TO SHORT SIDE RATIO OF 1.5 TO 1.
CONTROL JOINTS IN SLABS ON GRADE SHALL NOT RECEIVE JOINT FILLER MATERIAL UNLESS NOTED OTHERWISE.
JK
C8.5
C8.1
C7.5
SF501
16' - 0"
EXISTING COLUMN
2'
/4
2'
6'
/4
EXISTING COLUMN
EXISTING COLUMN
EXISTING BUILDING
EXISTING BUILDING
14' - 0" 2' - 6"
3'
4" SLAB ON GRADE W/ WELDED WIRE FABRIC.
T/SLAB = MATCH EXISTING
CJ
CJ
CJ
CJ
CJ
JK
C8.5
C8.1
C7.5
W10X19
W10X19
W10X19
W10X19
W10X19
W10X19
W10X19
W10X19
W10X19
W10X19
W X
W X
W X
E X
IS
T
IN
G
W
X
B E
A M
E X
IS
T
IN
G
W
X
B E
A M
HSS5X5X3/16
HSS5X5X3/16
HSS5X5X3/16
HSS5X5X3/16
16' - 0"
EXISTING COLUMN
3/ 4"
E
Q . S
P A
C E
S
E Q
. S P
A C
E S
E
Q . S
P A
C E
S
SF501
W X
W X
W X
SF501
SF501
EXISTING COLUMN
EXISTING COLUMN
2' - 4" 13' - 8"
K
K
K
K
NOTES:
1. ALL CONNECTIONS TO BE DESIGNED FOR A MINIMUM 6 KIPS IN SHEAR UNLESS NOTED OTHERWISE
2. REFERENCE FINISH FLOOR ELEVATION = 100'-0" = EXISTING HOSPITAL FINISH FLOOR
3. T/STEEL = 115'-5 1/2". CONTRACTOR TO FIELD VERIFY EXISTING T/STEEL.
4. CONTRACTOR TO FIELD VEIRFY ALL EXISTING BEAM SIZES
EXISTING CANOPY
EXISTING BUILDING
1 1/2" 20
GAGE METAL
ROOF DECK
SB101
8' - 2"
6' - 2" 2' - 0"
8' - 2"
8' - 2"
2'
/4
SEE SCREENWALL
FRAMING PLAN FOR
COLUMN SIZE, TYP
1/
2"
/4
6'
W X
W X
W X
C8.5
C8.1
8' - 2"
SF501
/4
2'
4'
3/ 4"
9'
/4
7'
/4
1' - 9 1/2"
1' - 9 1/2"
1' - 9 1/2"
1'
/2
L3X3X3/8 KICKER, TYP
HSS5X5X3/16
HSS5X5X3/16
HSS5X5X3/16
HSS5X5X3/16
HSS5X5X3/16
HSS4X4X1/4
H S
S X
X
/4
H S
S X
X
/4
H S
S X
X
/4
JK
C8.5
C8.1
C7.5
SF501
16' - 0"
/4
/4
2'
6'
EXISTING COLUMN
/4
2'
6'
/4
EXISTING COLUMN
EXISTING COLUMN
EXISTING BUILDING
EXISTING BUILDING
T/FTG = 98' - 6" TYP
4'X4'X12" SPREAD
FOOTING, TYP
3'x3' CONCRETE PIER, TYP
T/PIER = MATCH
EXISTING SLAB, TYP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs
\m v a n d e rw o u d e \D o c u m e n ts \1
.1
.0
E le c tr ic P a n e l V m v a n d e rw o u d e
.r v t
/1
/2
:1
:5
P
M
SB101
FOUNDATION AND FRAMING
PLANS
EXPAND EXISTING EMERGENCY
DISTRIBUTION PANEL BOARD & ADD
COOLING TO SUBSTATION ROOM
CHALMERS P. WYLIE VAACC
757-19-202
1A
3/5/2021 MAV ADK
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/4" = 1'-0"SB101
2 SLAB ON GRADE PLAN
SCALE: 1/4" = 1'-0"SB101
3 FRAMING PLAN
NN
SCALE: 3/8" = 1'-0"SB101
4 SCREENWALL FRAMING PLAN
NOTES:
1. ALL CONNECTIONS TO BE DESIGNED FOR A MINIMUM 6 KIPS IN SHEAR UNLESS NOTED
OTHERWISE
2. REFERENCE FINISH FLOOR ELEVATION = 100'-0" = EXISTING HOSPITAL FINISH FLOOR
3. THREE BEAMS BEAMS CONNECTING COLUMN TO COLUMN. T/STL = 116'-11",
T/STL = 119'-3", AND T/STL = 121'-7"
SCALE: 1/4" = 1'-0"SB101
1 FOUNDATION PLAN
PROVIDE 1/2" ISOLATION
JOINT AGAINST EXISTING
BUILDING
DRILL AND EPOXY #4 BARS @
36" INTO EXISTING SLAB.
ENSURE PROPER
DEVELOPMENT LENGTH PER ACI
N
5/8" Ø PUDDLE WELD, TYP
3 - #10 TEX SIDELAP FASTENERS
EACH JOIST SPACE
36/4 WELD PATTERN AT ALL SUPPORTS
WELD REQUIRED AT ALL
SIDELAP SUPPORT POINTS
NOTE: WELD THROUGH MULTIPLE SHEETS AT ALL END AND SIDE
LAPS END LAPS SHALL OCCUR ONLY AT SUPPORT POINTS
1 1/2" WIDE RIB, 20 GAGE METAL ROOF
DECK - MINIMUM THREE SPAN CONDITION.
S E E P
LA
N
S E E P
LA
N
S E E P
LA
N
S H E E T W
ID
T H
J
(8) #6 BARS TOP AND BOTTOM
T/FTG =
PER PLAN
T/PIER
PER PLAN
COLUMN PER PLAN
PIER PER PLAN
FOOTING PER PLAN
TYP
3" CLR
(4) #5 BARS
#4 TIES @ 6"
1/2" ISOLATION JOINT
1'
1'
M
IN
2'
#4 TIES @ 3"
SLAB PER PLANEXISTING SLAB
DRILL AND EPOXY #4 BARS @ 36" INTO
EXISTING SLAB. ENSURE PROPER
DEVELOPMENT LENGTH PER ACI
K
CONTINUOUS BENT PLATE
1/2"
STANDARD
AISC SHEAR
CONNECTION
EXISTING BUILDING
ROOF DECK PER PLAN
3/16" 2-12
BEAM PER PLAN
T/STEEL =
PER PLAN
4"
2' - 4"
3 1/2"
3"
K
SINGLE ANGLE SHEAR
CONNECTION
EXISTING BEAM PER PLAN
BEAM PER PLAN
T/STEEL =
PER PLAN
ROOF DECK PER PLAN
BEAM PER PLAN
STANDARD AISC SHEAR
CONNECTION
COLUMN PER PLAN
2 1/2"
L3X3X1/4"
CONTINOUS
3/16" 2-12
T/STEEL =
PER PLAN
1'
4"
T/STL = 119'-3"
T/STL = PER PLAN
T/STL = 121'-7"
T/STL = 116'-11"
PROVIDE 1/4" CAP PLATE
SCREENWALL COLUMN PER PLAN
KICKER PER PLAN
SCREENWALL BEAM PER
PLAN, TYP
3/16
3/16
4"
4"
BEAM PER PLAN ROOF DECK PER PLAN
1/2"
SCREENWALL PANEL. SEE ARCH
W / A
R C
H
C O
O R
D
IN
A T
E
3/4" DIA BOLT, TYP
3/8" PLATE, TYP
SEE BASEPLATE
DETAIL 7/SF501
PLAN SECTION
COLUMN PER PLAN
LEVELING
NUTS
3/4" DIA. ANCHOR RODS W/
12" MIN EMBEDMENT.
HEAVY HEX NUT
AND WASHER
1 1/2" 1 1/2"
1/
2"
1/ 2"
G R
O U
T 2"
N O
N -S
H R
IN
K
5/16
1'
1' - 0"1" THICK BASE PLATE. USE PROVIDE HOLES
AND PLATE WASHERS IN ACCORDANCE WITH
AISC RECOMMENDATIONS FOR ANCHOR RODS.
1/4" END PLATE, TYP
3/16
TYP
3/8"X4""X4" PLATE W/ 3/4"
DIA BOLT GALV, TYP
PROVIDE 1/4" CAP PLATE, TYP
3/8"X6"X4" PLATE, TYP
3/16
TYP
COLUMN PER PLAN
BEAM PER PLAN, TYP
3/16"
3/16"
4"
6"
4"
2" VARIES 2"
2"
1/ 4"
2"
3/ 4"
SCREENWALL COLUMN PER PLAN2" 2"
1/2" PLATE
WITH 3/4" DIA
A325 BOLTS
1/4"
BEAM PER PLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs
\m v a n d e rw o u d e \D o c u m e n ts \1
.1
.0
E le c tr ic P a n e l V m v a n d e rw o u d e
.r v t
/1
/2
:1
:0
P
M
SF501
FRAMING SECTIONS AND DETAILS EXPAND EXISTING EMERGENCY
DISTRIBUTION PANEL BOARD & ADD
COOLING TO SUBSTATION ROOM
CHALMERS P. WYLIE VAACC
757-19-202
1A
3/5/2021 MAV ADK
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 3/4" = 1'-0"SF501
1 TYPICAL DECK WELDING PATTERN
SCALE: 1" = 1'-0"SF501
5 FOUNDATION SECTION
SCALE: 1 1/2" = 1'-0"SF501
3 FRAMING SECTION
SCALE: 1 1/2" = 1'-0"SF501
2 FRAMING SECTION
SCALE: 1 1/2" = 1'-0"SF501
4 FRAMING SECTION
SCALE: 3/4" = 1'-0"SF501
9 SCREENWALL FRAMING SECTION
SCALE: 3/4" = 1'-0"SF501
6 TYPICAL FOUNDATION BASE PLATE
SCALE: 1 1/2" = 1'-0"SF501
8 SCREENWALL COLUMN CONNECTION
SCALE: 1 1/2" = 1'-0"SF501
7 SCREENWALL COLUMN BASEPLATE
ARCHITECTURAL ABBREVIATIONS
SECTION REFERENCE
DRAWING NUMBER
SHEET LOCATION
DRAWING NUMBER
SHEET
LOCATION
DETAIL REFERENCE
OBJECT
REFERENCED
OBJECT
REFERENCED
X
XXXX
X
XXXX
SCALE: ??
VIEW TITLE
N
NORTH ARROW
INCANDESCENT SURFACE MOUNT LIGHTING
EXIT LIGHTING
INCANDESCENT RECESSED LIGHTING
A 9'-0"
CEILING TAG CEILING TYPE
FINISHED CEILING HEIGHT
REFER TO CEILING LEGEND FOR MORE
INFORMATION
EXTENT OF REVISION
REVISION SET
MECH/ELEC ITEMS: REFER TO MEP SHEETS AS APPLICABLE
PROJECT BOUNDARY
BEYOND PROJECT BOUNDARY, NIC
REFLECTED CEILING PLAN SYMBOLS
DETAIL/DRAWING SCALE
TITLE OF DETAIL/DRAWING
DETAIL/DRAWING NUMBER
SHEET NUMBER
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
AFF ABOVE FINISHED FLOOR
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALUM ALUMINUM
AMT AMOUNT
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
ARCH ARCHITECT
AUX AUXILIARY
AVG AVERAGE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWS AMERICAN WELDING SOCIETY
B PL BASE PLATE
BLD BUILD
BLDG BUILDING
BLKG BLOCKING
BOT BOTTOM
BRCG BRACING
BRKT BRACKET
CLG COUNTERFLASHING
CIP CAST-IN-PLACE
CJ CONSTRUCTION JOINT OR CONTROL JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONSTR CONSTRUCTION
CONT CONTINUE
CORR CORRIDOR
CTR CENTER
CTRL CONTROL
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
O/O OUT TO OUT
OC ON CENTER
OFD OVERFLOW DRAIN
OPNG OPENING
OPP OPPOSITE
PERIM PERIMETER
PLYWD PLYWOOD
PROJ PROJECT
PROP PROPERTY
PTN PARTITION
QTY QUANTITY
QUAL QUALITY
RCP REFLECTED CEILING PLAN
REQD REQUIRED
RV ROOF VENT
W/ WITH
W/O WITHOUT
WBL WOOD BLOCKING
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WFR WOOD FRAME
WPM WATERPROOF MEMBRANE
WWF WELDED WIRE FABRIC
XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)
GENERAL CONSTRUCTION NOTES
1. THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING REVIT®
SOFTWARE IN A MICROSOFT WINDOWS ENVIRONMENT. A BUILDING INFORMATION
MODEL (BIM) HAS BEEN DEVELOPED FOR DESIGN COMMUNICATION. THE MODEL
DOES NOT CONTAIN COMPLETE INFORMATION FOR USE IN COST ESTIMATING,
SYSTEMS PERFORMANCE, COORDINATION, SCHEDULING, OR FACILITIES
MANAGEMENT.
2. THE CONTRACT DOCUMENT DRAWINGS HAVE BEEN PREPARED USING THE
CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM AND THE
NATIONAL CAD STANDARD AS GUIDES.
3. DISCREPANCIES IN THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELY BROUGHT
TO THE ATTENTION OF THE ARCHITECT AND OWNER’S REPRESENTATIVE/COR.
CONTRACTOR SHALL PROVIDE THE HIGHER GRADE OF QUALITY AND/OR GREATER
QUANTITY OF WORK WHEN BIDDING IF A CLARIFICATION CAN NOT BE OBTAINED BY
THE BID DUE DATE.
4. CONTRACTOR IS RESPONSIBLE FOR COORDINATING SCOPE OF WORK WITH
OWNER’S REPRESENTATIVE/COR AND VARIOUS FACILITY PERSONNEL INVOLVED
WITH UTILITY SHUT DOWN, INFECTION CONTROLS, OCCUPANT/EMPLOYEE SAFETY,
ACCESS CONTROL, ETC.
5. ANY INDICATION OF PROJECT LIMITS OR BOUNDARY OF DEMARCATION ARE SHOWN
FOR THE CONVENIENCE OF THE CONTRACTOR, THE FULL SCOPE OF THE PROJECT
LIMIT OF BOUNDARY REQUIRES COORDINATION WITH THE DESIGN SCOPE OF WORK
AND ACCESS TO EXISTING UTILITIES FOR TIE IN.
6. DRAWINGS ARE PREPARED FROM FIELD VERIFICATION, EXISTING FACILITY DRAWING
BASE FILES, AND USING DIMENSIONS, CONFIGURATIONS AND DETAILS OF SPECIFIC
MANUFACTURERS AS A BASIS OF DESIGN. CONTRACTOR IS RESPONSIBLE FOR
VERIFICATION OF ACTUAL DIMENSIONS, THE COORDINATION OF THE DETAILS WITH
THE PRODUCTS WHICH ARE PROVIDED PER THE SCOPE OF THE SPECIFICATIONS
AND THE SURROUNDING CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS,
ROUGH-IN DIMENSIONS, CONNECTIONS, AND OVERALL INSTALLATION
REQUIREMENTS.
7. CONTRACTOR IS RESPONSIBLE FOR THE COMPLETION OF THE ENTIRE SCOPE OF
WORK OUTLINED IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE
FOR THE COORDINATION OF ALL SUB-CONTRACTORS AND THE SCOPE OF WORK
THEY PROVIDE. SUB-CONTRACTORS ARE RESPONSIBLE FOR THEIR FULL SCOPE OF
WORK WITHIN THE CONTRACT DOCUMENTS, TRADES ARE NOT SEGMENTED TO ONLY
CERTAIN SHEETS AND SPECIFICATIONS, CROSS COORDINATION IS REQUIRED.
8. CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR
UNDERSTANDING INFORMATION OUTLINED IN THE SPECIFICATIONS, KEY NOTES,
GENERAL NOTES, LEGEND, CODES, ETC., PROVIDED IN THE CONTRACT DOCUMENTS.
9. CONTRACTOR AND SUB-CONTRACTORS ARE BOTH RESPONSIBLE FOR PROVIDING
AND MAINTAINING SMOKE/FIRE RATINGS OF NEW CONSTRUCTION AND EXISTING
CONSTRUCTION AS INDICATED ON DRAWINGS. THIS INCLUDES PATCHING
PENETRATIONS IN SHAFTS, WALLS, SLABS AND ROOF. ONLY U.L. APPROVED
METHODS, MATERIALS AND INSTALLATION ARE ACCEPTABLE.
10. MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL DRAWINGS SHOW
INFORMATION IN A DIAGRAMMATIC FASHION WITHOUT DIMENSIONING. THE GENERAL
CONTRACTOR IS TO COORDINATE THE LOCATIONS OF ALL MECHANICAL, PLUMBING
AND ELECTRICAL EQUIPMENT WITH RESPECT TO THE ARCHITECTURAL AND
STRUCTURAL DETAILING OF SHAFTS, CHASES, CEILING CONSTRUCTION, ETC.
11. CONTRACTOR IS RESPONSIBLE FOR VERIFYING DIMENSIONS IDENTIFIED AND NOT
IDENTIFIED IN THE CONTRACT DOCUMENTS WITH THE EXISTING AND NEW
CONSTRUCTION ELEMENTS. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION
BETWEEN THE CONTRACT DOCUMENTS, INSTALLED AND UNINSTALLED
CONSTRUCTION BEFORE THE ORDERING OF MATERIALS AND EQUIPMENT. NOTIFY
ARCHITECT AND OWNER’S REPRESENTATIVE/COR OF ANY DISCREPANCIES OR
MISSING DIMENSIONS.
12. DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR GENERAL
ORIENTATION AND CONTEXT ONLY.
13. THE TERM "ALIGN" MEANS TO INSTALL DIFFERENT/SIMILAR COMPONENTS OF
CONSTRUCTION TO PROVIDE A FLUSH FINISH SURFACE.
14. ALL DIMENSIONS INDICATED ARE TO FACE OF EXISTING MEMBERS, FACE OF NEW
STRUCTURAL MEMBERS, FACE OF NEW MASONRY, FACE OF NEW STUDS OR COLUMN
GRID LINES UNLESS NOTED OTHERWISE.
15. FLOOR ELEVATION 100’-0” IS EQUAL TO THE FINISH FLOOR SLAB OF THE EXISTING
SLAB FLOOR CONSTRUCTION UNLESS OTHERWISE NOTED.
16. CONTRACTOR TO PROVIDE WORK WHERE DETAILS AND NOTES ARE IDENTIFIED AS
“TYPICAL” OR “SIMILAR” EACH INSTANCE THAT IS THE SAME IN NATURE TO THE
DETAIL, AREA, OR ITEM REFERENCED.
17. PROVIDED WORK SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR.
CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DELIVERY, MOUNTING,
INSTALLATION, NECESSARY BLOCKING AND ROUGH-IN.
18. ALL PROVIDED WORK SHALL BE WITH NEW MATERIALS UNLESS SPECIFICALLY
CALLED OUT AS SALVAGED OR RELOCATED WITHIN THE CONTRACT DOCUMENTS.
19. ALL PERSONS DIRECTLY OR INDIRECTLY ASSOCIATED WITH THE PROJECT SHALL BE
FAMILIAR WITH THE RULES AND REGULATIONS OF THE OCCUPATIONAL SAFETY AND
HEALTH ACT, AND IMPLEMENT THOSE RULES AS THEY APPLY TO THIS PROJECT.
20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL
UTILITY LINES. LOCATIONS SHOWN ARE APPROXIMATE. REPAIR ALL DAMAGE TO
UTILITY LINES CAUSED BY CONSTRUCTION OPERATIONS AT NO COST TO THE
OWNER.
21. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING AND SHORING
REQUIRED DURING CONSTRUCTION.
22. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ADJACENT
CONSTRUCTION, FINISHES, EQUIPMENT, AND TRAVEL ROUTE TO AND FROM THE
CONSTRUCTION SITE. ANY DAMAGE OR UNACCEPTABLE WEAR BY THE
CONSTRUCTION TEAM SHALL BE REPAIRED/REPLACED BY THE CONTRACTOR AT NO
COST TO THE OWNER.
23. IN THE CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT
DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER
QUALITY OF WORK, AS DETERMINED BY THE OWNERS REP / COR, SHALL BE
PROVIDED.
DEMO DEMOLITION
DIA DIAMETER
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
EMER EMERGENCY
ENGR ENGINEER
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ERD EXISTING ROOF DRAIN
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER
FAS FASCIA
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FF FINISH FACE
FIN FINISH
FLASH FLASHING
FLEX FLEXIBLE
FLR FLOOR
FO FINISHED OPENING
FRMG FRAMING
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
GA GAGE OR GYPSUM ASSOCIATION
GALV GALVANIC OR GALVANIZED
GC GENERAL CONTRACTOR
GUAR GUARANTEE
GUT GUTTER
GYP GYPSUM
H HIGH
HDW HARDWARE
HMD HOLLOW METAL DOOR
HMF HOLLOW METAL FRAME
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATING, AND AIR CONDITIONING
IBC INTERNATIONAL BUILDING CODE
INCL INCLUDED
INSUL INSULATION
INT INTERIOR
JT JOINT
LBS POUND
LF LINEAR FEET (FOOT)
LRG LARGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LVR LOUVER
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MTD MOUNTED
MTG MOUNTING
MTL METAL
ARCHITECTURAL SYMBOLS
X
X
XXXX
SHEET LOCATION
VIEW NUMBER
X X
X
SHEET LOCATION
VIEW NUMBER
XXXX
BUILDING SECTION REFERENCE
DRAWING NUMBER
SHEET LOCATION
BUILDING X
XXXX
X
XXXX
ELEVATION REFERENCES
S3A.G
INDICATES STRUCTURAL MATERIAL
INDICATES NOMINAL SIZE
INDICATES STRUCTURE AND FINISH HEIGHTS
INDICATES QUALIFER
TEMPORARY IC
BARRIER WALL
CONSTRUCTION EXISTING DOOR
SBSTR SUBSTRATE
SCP SCUPPER
SDG SIDING
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SIM SIMILAR
SLNT SEALANT
SM SHEET METAL
SPKLR SPRINKLER
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
TEMP TEMPERATURE OR TEMPORARY
THK THICKNESS
THRU THROUGH
TO TOP OF ___
TO FDN TOP OF FOUNDATION
TOS TOP OF STEEL
TRTD TREATED
TYP TYPICAL
UTIL UTILITY
VAR VARIES
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VNR VENEER
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
REVISION TO PLAN CALLOUT
WALLS
DOOR TAG
KEY NOTE TAGS
WALL TAG : REFER TO WALL LEGEND FOR MORE INFORMATION
DOORS
PT-1
A
T
FINISH INDICATION
FRAME / WINDOW
GLAZING1
1 PLAN NOTE
1 DEMOLITION NOTE
ALTERNATE/BID DEDUCT ITEM
KEY NOTE SYMBOLS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
100% Construction Documents 6/1/20
95% Construction Documents 4/17/20
65% Design Development 11/27/19
35% Schematic Design 03/27/19
Bid Documents 8/19/20
C U s e rs
\m v a n d e rw o u d e \D o c u m e n ts \1
.1
V A
V
IS
N v m v a n d e rw o u d e
.r v t
/1
/2
:2
:1
P
M
AE001
ARCHITECTURAL SYMBOLS AND
ABBREVIATIONS
EXPAND EXISTING EMERGENCY
DISTRIBUTION PANEL BOARD & ADD
COOLING TO SUBSTATION ROOM
CHALMERS P. WYLIE VAACC
757-19-202
1A
3/5/2021 JF MAE
BID DOCUMENTS
FULLY SPRINKLERED
S2
AS SCHEDULED 2" TYP
7'
A S
S C
H E
D U
LE
D
AS SCHEDULED
AE002
TYP
AE002
TYP
DOOR AND FRAME TYPE LEGEND
FL
DOOR TYPE ABBREVIATIONS
FL FLUSH
SF STOREFRONT
DOOR MATERIAL ABBREVIATIONS
AL ALUMINUM
HM HOLLOW METAL
WD WOOD
FRAME TYPE ABBREVIATIONS
S2 SINGLE / 2" HEAD
W2 DOUBLE w/DIFFERENT WIDTH / 2" HEAD
FRAME MATERIAL ABBREVIATIONS
AL ALUMINUM
HM HOLLOW METAL
WD WOOD
ANOD ANODIZED
SF1
A S
S C
H E
D U
LE
D
AS SCHEDULED
SF
A S
S C
H E
D U
LE
D
AS SCHEDULED
FL FL
BA
1. PROVIDE CARD READER AND ASSOCIATED ACCESSORIES. PROVIDE
ELECTRIC STRIKE AND OR ELECTRIFIED EXIT DEVICES AS REQUIRED. REFER
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .