This is a Hazardous/Regulated Materials Survey & Inspection Report prepared by Environmental Testing & Consulting, Inc. for the City of Detroit Demolition Department regarding the property at 14635 Bentler Street, Detroit, MI 48223. The inspection was conducted on August 3, 2026, with the report issued on August 12, 2026, in support of a planned residential demolition project (Group 9.3.26). The single-story residential structure, built in 1948 with a concrete slab foundation and 572 square feet of total area, was surveyed for asbestos-containing materials, hazardous materials, and structural conditions. The engineering survey identified significant fire and structural damage, including a completely burned roof and absent attic space. Laboratory analysis using Polarized Light Microscopy identified asbestos-containing materials in two product categories: 9x9 brown floor tile containing 3% chrysotile asbestos (199 square feet located in functional spaces FS-1 and FS-5) and white exterior caulk containing 5% chrysotile asbestos (190 linear feet located in exterior areas EA-1 through EA-4). All other tested materials, including drywall board, stack cement, window glazing, tile mastic, cinderblock, mortar, concrete, roofing shingles, and tar paper, tested negative for asbestos or contained trace amounts below the 1% threshold for classification as asbestos-containing materials.
The report establishes baseline conditions for the demolition contractor, who bears responsibility for verifying all quantities of identified asbestos during the bidding process and ensuring compliance with OSHA and EPA regulations for removal and disposal of the detected asbestos-containing materials. No other hazardous materials or regulated substances were detected at the property. The inspection documentation includes detailed chain of custody records, site drawings, photographic evidence of structural damage, and comprehensive laboratory certification from Environmental Testing Laboratories, Inc., with analysis conducted by qualified Michigan Asbestos Inspectors and reviewed by licensed professionals. The findings serve as the basis for preparation of the demolition scope of work and contractor bid requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hazardous/Regulated Materials Survey & Inspection Report
14635 Bentler Street, Detroit, MI 48223 Parcel #: 22110990.
Date of Inspection: 08/03/2026 Date of Report: 08/12/2026
Prepared For:
City of Detroit Demolition Department
1301 3rd Avenue, 6th Floor
Detroit, MI 48226
Project #: 2026 BPO 7.20.2026
Fieldwork conducted by: Report Reviewed and Approved by:
Andre Richardson Mark Smith Michigan Asbestos Inspector License #: A45125 Michigan Asbestos Inspector License #: A55707 Inspector’s E-Mail: Andre.Richardson@2etc.com E-Mail: Mark.Smith@2etc.com
38900 West Huron River Drive Romulus, MI 48174
734-955-6600 www.2etc.com
Hazardous/Regulated Materials Survey & Inspection Report ETC Job #: 293125
14635 Bentler Street, Detroit, MI 48223 Parcel #: 22110990.
Asbestos Containing Materials
TABLE 1: ASBESTOS CONTAINING MATERIALS
Category Material Description Location Quantity
M 9x9 Floor Tile, Brown FS 1,5 199 SF
M Exterior Caulk, White EA 1-4 190 LF TSI = Thermal System Insulation; S = Surfacing; M = Miscellaneous; SF= Square Feet; LF = Linear Feet;
CY = Cubic Yards; CF = Cubic Feet
Quantities that are listed are estimates only. It is the contractor’s responsibility to verify all amounts of asbestos identified during the bid process.
Hazardous Materials & Tires
TABLE 2: HAZARDOUS MATERIALS
Material Description Location Quantity
None Detected
Engineering Survey
14635 Bentler Street
Reviewed 08/2025
Pre-Demolition Engineering Survey Report
Detroit, MI 48223
Prepared for City of Detroit Demolition Department
1301 Third Street, 6th Floor Detroit, Michigan 48226
Prepared by Environmental Testing & Consulting, Inc.
38900 West Huron River Drive Romulus, MI 48174
Report Date July 31, 2026
Reviewed 08/2025
Survey Details and Site Information Date(s) of Engineering Survey: July 29, 2026
Engineering Survey Inspector name: Jeremy Westcott
Engineering Survey Inspector #: INSP01045
Engineering Survey Inspector email: Jeremy.Westcott@2etc.com
Engineering Survey Inspector phone #: 734-955-6600
Engineering Survey Inspector signature:
Reviewing PE/Architect name:
Reviewing PE/Architect license state/#:
Reviewing PE/Architect email:
Reviewing PE/Architect phone #:
Reviewing PE/Architect signature:
Property Address: 14635 Bentler Street, Detroit, MI 48223
# and types of structure(s): 1 House
Foundation type Concrete Slab
Year built: 1948
# of floors: 1
Total square footage: 572 ft2
William Earle, P.E. (WI)
WI 35407-6
William.Earle@oneatlas.com
847-971-0979
Reviewed 08/2025
Engineering Survey Findings – Exterior Areas Designation Inaccessible Reason Description/Notes
EA-1
EA-2
EA-3
EA-4
EA-5
Key:
• Inaccessible: “P” = Partially inaccessible; “C” = Completely inaccessible
• Reason: “F” = Fire damage, “W” = Water damage, “S” = Structural damage, “T” = Termite damage, “O” = Other damage
C F, S Roof has burned
Reviewed 08/2025
Engineering Survey Findings – Functional Spaces Designation Inaccessible Reason Description/Notes
FS-1
FS-2
FS-3
FS-4
FS-5
FS-6 C F Attic is burned away
Key:
• Inaccessible: “P” = Partially inaccessible; “C” = Completely inaccessible
• Reason: “F” = Fire damage, “W” = Water damage, “S” = Structural damage, “T” = Termite damage, “O” = Other damage
Reviewed 08/2025
Site Drawings
Reviewed 08/2025
Site Photographs
EA1 EA2
EA3 EA4
Reviewed 08/2025
EA5 FS1
FS2 FS3
Reviewed 08/2025
FS4 FS5
FS6 – Attic Gone
Electronic Chain of Custody
Submitting Client:
Detroit, MI - 48226
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Environmental Testing Laboratories, Inc.
City of Detroit - Demolition Department
1301 Third Street - Suite 606
Asbestos-Bulk
72 Hours
Yes
Yes, 400.00 Points
DETROIT DEMO
Sample Type:
Turn Around:
Positive Stop:
Point Counting:
P.C. Criteria:
Sample ID Client Sample ID
ETL Project :Project Location: 29312514635 Bentler St, Detroit, MI 48223
Collection DateSample Location Sample Description
1915215 2026-08-031A FS3 Ceiling / Wall / Drywall Board - White - HA(1)
1915216 2026-08-031B FS3 Ceiling / Wall / Drywall Board - White - HA(1)
1915217 2026-08-031C FS3 Ceiling / Wall / Drywall Board - White - HA(1)
1915218 2026-08-032A FS3 Mortar / Stack Cement - Grey - HA(2)
1915219 2026-08-032B FS3 Mortar / Stack Cement - Grey - HA(2)
1915220 2026-08-032C FS3 Mortar / Stack Cement - Grey - HA(2)
1915221 2026-08-033A EA1 Wall (Ext.) / Window (Glazing) - White - HA(3)
1915222 2026-08-033B EA2 Wall (Ext.) / Window (Glazing) - White - HA(3)
1915223 2026-08-033C EA3 Wall (Ext.) / Window (Glazing) - White - HA(3)
1915224 2026-08-034A FS1 Floor / Tile - 9x9 - Brown - HA(4)
1915225 2026-08-034B FS5 Floor / Tile - 9x9 - Brown - HA(4)
1915226 2026-08-034C FS1 Floor / Tile - 9x9 - Brown - HA(4)
1915227 2026-08-035A FS1 Floor / Tile Mastic - Black - HA(5)
1915228 2026-08-035B FS5 Floor / Tile Mastic - Black - HA(5)
1915229 2026-08-035C FS1 Floor / Tile Mastic - Black - HA(5)
1915230 2026-08-036A EA1 Cinderblock - Grey - HA(6)
1915231 2026-08-036B EA2 Cinderblock - Grey - HA(6)
1915232 2026-08-036C EA3 Cinderblock - Grey - HA(6)
1915233 2026-08-037A EA1 Mortar / Block - Grey - HA(7)
1915234 2026-08-037B EA2 Mortar / Block - Grey - HA(7)
Sample ID Client Sample ID
ETL Project :Project Location: 29312514635 Bentler St, Detroit, MI 48223
Collection DateSample Location Sample Description
1915235 2026-08-037C EA3 Mortar / Block - Grey - HA(7)
1915236 2026-08-038A EA1 Caulk / Exterior - White - HA(8)
1915237 2026-08-038B EA2 Caulk / Exterior - White - HA(8)
1915238 2026-08-038C EA3 Caulk / Exterior - White - HA(8)
1915239 2026-08-039A EA1 Concrete / Walkway - Grey - HA(9)
1915240 2026-08-039B EA2 Concrete / Walkway - Grey - HA(9)
1915241 2026-08-039C EA3 Concrete / Walkway - Grey - HA(9)
1915242 2026-08-0310A FS1 Concrete / Floor - Grey - HA(10)
1915243 2026-08-0310B FS2 Concrete / Floor - Grey - HA(10)
1915244 2026-08-0310C FS3 Concrete / Floor - Grey - HA(10)
1915245 2026-08-0311A EA5 Roofing / Asphalt (Shingles) - Grey - HA(11)
1915246 2026-08-0311B EA5 Roofing / Asphalt (Shingles) - Grey - HA(11)
1915247 2026-08-0311C EA5 Roofing / Asphalt (Shingles) - Grey - HA(11)
1915248 2026-08-0312A EA5 Roofing / Asphalt (Shingles) - Black - HA(12)
1915249 2026-08-0312B EA5 Roofing / Asphalt (Shingles) - Black - HA(12)
1915250 2026-08-0312C EA5 Roofing / Asphalt (Shingles) - Black - HA(12)
1915251 2026-08-0313A EA5 Roofing / Tar Paper - Black - HA(13)
1915252 2026-08-0313B EA5 Roofing / Tar Paper - Black - HA(13)
1915253 2026-08-0313C EA5 Roofing / Tar Paper - Black - HA(13)
Seal Intact:
Preservative (if required):
Containers Labled :
Yes
Yes
Analyst
Yes
Sample ID Client Sample ID
ETL Project :Project Location: 29312514635 Bentler St, Detroit, MI 48223
Collection DateSample Location Sample Description
Received By:
Received Date:
Relinquished By:
Relinquished Date:
Bella Rossi
2026-08-04 12:00 AM
Andre Richardson
Aug 4 2026 12:00AM Chris Canilao
OJ Ivey
Material List
Client : City of Detroit - Demolition Department 1301 Third Street - Suite 606 Detroit, MI - 48226
Project Location: 14635 Bentler st. Detroit Mi. Job #:293125
Material Id Material Description Material Sub Classification Size Quantity Locations
1 Ceiling / Wall/D rywall Board-White Drywall Board M 20 S F F S-03
2 Mortar/S tack Cement-Grey Stack Cement M 5 S F F S-03
3 Wall (Ext.)/Window (Glazing)-White Window (Glazing) M 6 Unit E A-01,E A-02,E A-03,E A-04
4 F loor/Ti le-9x9-Brown Tile M 9x9 199 S F F S-01,F S-05
5 F loor/Ti le Mastic-B lack Tile Mastic M 199 S F F S-01,F S-05
6 C inderblock-Grey M 1580 S F E A-01,E A-02,E A-03,E A-04
7 Mortar/B lock-Grey B lock M 1580 S F E A-01,E A-02,E A-03,E A-04
8 Caulk/Exterior-White Exterior M 190 LF E A-01,E A-02,E A-03,E A-04
9 Concrete/Walkway-Grey Walkway M 185 S F E A-01,E A-02,E A-03,E A-04
10 Concrete/F loor-Grey F loor M 550 S F F S-01,F S-02,F S-03,F S-04,F S-05
11 Roofing/Asphalt (Shingles)-Grey Asphalt (Shingles) M 650 S F E A-05
12 Roofing/Asphalt (Shingles)-B lack Asphalt (Shingles) M 650 S F E A-05
13 Roofing/Tar Paper-B lack Tar Paper M 650 S F E A-05
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive Romulus, Michigan 48174
(734) 955-6600
Fax: (734) 955-6604
To:
Attention:
Environmental Testing And Consulting Inc.
38900 Huron River Drive
Romulus, MI 48174
Project Location: 14635 Bentler St, Detroit, MI 48223
Client Project: 293125
293125ETL Job:
Al Dyer
Report Issued: 08/07/2026
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
1915215 Asbestos1A 08/07/2026 OJ Ivey08/03/2026
1915216 Asbestos1B 08/07/2026 OJ Ivey08/03/2026
1915217 Asbestos1C 08/07/2026 OJ Ivey08/03/2026
1915218 Asbestos2A 08/07/2026 OJ Ivey08/03/2026
1915219 Asbestos2B 08/07/2026 OJ Ivey08/03/2026
1915220 Asbestos2C 08/07/2026 OJ Ivey08/03/2026
1915221 Asbestos3A 08/07/2026 OJ Ivey08/03/2026
1915222 Asbestos3B 08/07/2026 OJ Ivey08/03/2026
1915223 Asbestos3C 08/07/2026 OJ Ivey08/03/2026
1915224 Asbestos4A 08/07/2026 OJ Ivey08/03/2026
1915225 Asbestos4B 08/07/2026 OJ Ivey08/03/2026
1915226 Asbestos4C 08/07/2026 OJ Ivey08/03/2026
1915227 Asbestos5A 08/07/2026 OJ Ivey08/03/2026
1915228 Asbestos5B 08/07/2026 OJ Ivey08/03/2026
1915229 Asbestos5C 08/07/2026 OJ Ivey08/03/2026
1915230 Asbestos6A 08/07/2026 OJ Ivey08/03/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
1915231 Asbestos6B 08/07/2026 OJ Ivey08/03/2026
1915232 Asbestos6C 08/07/2026 OJ Ivey08/03/2026
1915233 Asbestos7A 08/07/2026 OJ Ivey08/03/2026
1915234 Asbestos7B 08/07/2026 OJ Ivey08/03/2026
1915235 Asbestos7C 08/07/2026 OJ Ivey08/03/2026
1915236 Asbestos8A 08/07/2026 OJ Ivey08/03/2026
1915237 Asbestos8B 08/07/2026 OJ Ivey08/03/2026
1915238 Asbestos8C 08/07/2026 OJ Ivey08/03/2026
1915239 Asbestos9A 08/07/2026 Chris Canilao08/03/2026
1915240 Asbestos9B 08/07/2026 Chris Canilao08/03/2026
1915241 Asbestos9C 08/07/2026 Chris Canilao08/03/2026
1915242 Asbestos10A 08/07/2026 Chris Canilao08/03/2026
1915243 Asbestos10B 08/07/2026 Chris Canilao08/03/2026
1915244 Asbestos10C 08/07/2026 Chris Canilao08/03/2026
1915245 Asbestos11A 08/07/2026 Chris Canilao08/03/2026
1915246 Asbestos11B 08/07/2026 Chris Canilao08/03/2026
1915247 Asbestos11C 08/07/2026 Chris Canilao08/03/2026
1915248 Asbestos12A 08/07/2026 Chris Canilao08/03/2026
1915249 Asbestos12B 08/07/2026 Chris Canilao08/03/2026
1915250 Asbestos12C 08/07/2026 Chris Canilao08/03/2026
1915251 Asbestos13A 08/07/2026 Chris Canilao08/03/2026
1915252 Asbestos13B 08/07/2026 Chris Canilao08/03/2026
1915253 Asbestos13C 08/07/2026 Chris Canilao08/03/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
Reviewed by:
Summary
Sample Layer MasticMethod
PLM 35Dawson Bradley
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
Certificate of Analysis
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14635 Bentler St, Detroit, MI 48223
ETL Job :
Client Project :
293125
293125
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/03/2026
08/04/2026
Date Collected :
Date Received :
PLM None Detected 1915215
1A PLM 90% OtherPLM 10% CelluloseWhiteCeiling / Wall / Drywall Board -
White - HA(1) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915216
1B PLM 90% OtherPLM 10% CelluloseWhiteCeiling / Wall / Drywall Board -
White - HA(1) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915217
1C PLM 90% OtherPLM 10% CelluloseWhiteCeiling / Wall / Drywall Board -
White - HA(1) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915218
2A PLM 97% OtherPLM 3% CelluloseGreyMortar / Stack Cement - Grey -
HA(2) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915219
2B PLM 97% OtherPLM 3% CelluloseGreyMortar / Stack Cement - Grey -
HA(2) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915220
2C PLM 97% OtherPLM 3% CelluloseGreyMortar / Stack Cement - Grey -
HA(2) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14635 Bentler St, Detroit, MI 48223
ETL Job :
Client Project :
293125
293125
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/03/2026
08/04/2026
Date Collected :
Date Received :
PLM None Detected 1915221
3A PLM 98% OtherPLM 2% CelluloseWhiteWall (Ext.) / Window (Glazing) -
White - HA(3) Non-Fibrous
HomogenousEA1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915222
3B PLM 98% OtherPLM 2% CelluloseWhiteWall (Ext.) / Window (Glazing) -
White - HA(3) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915223
3C PLM 98% OtherPLM 2% CelluloseWhiteWall (Ext.) / Window (Glazing) -
White - HA(3) Non-Fibrous
HomogenousEA3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM 3% Chrysotile1915224
4A PLM 92% OtherPLM 5% CelluloseBrownFloor / Tile - 9x9 - Brown - HA(4)
Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
1915225
4B
Positive Stop
FS5
Analyst: OJ Ivey
Date Analyzed : 08/07/2026
Sample Not Analyzed
1915226
4C
Positive Stop
FS1
Analyst: OJ Ivey
Date Analyzed : 08/07/2026
Sample Not Analyzed
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14635 Bentler St, Detroit, MI 48223
ETL Job :
Client Project :
293125
293125
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/03/2026
08/04/2026
Date Collected :
Date Received :
PLM None Detected 1915227
5A PLM 95% OtherPLM 5% CelluloseBlackFloor / Tile Mastic - Black -
HA(5) Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915228
5B PLM 95% OtherPLM 5% CelluloseBlackFloor / Tile Mastic - Black -
HA(5) Non-Fibrous
HomogenousFS5
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915229
5C PLM 95% OtherPLM 5% CelluloseBlackFloor / Tile Mastic - Black -
HA(5) Non-Fibrous
HomogenousFS1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915230
6A PLM 99% OtherPLM 1% CelluloseGreyCinderblock - Grey - HA(6)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915231
6B PLM 99% OtherPLM 1% CelluloseGreyCinderblock - Grey - HA(6)
Non-Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915232
6C PLM 99% OtherPLM 1% CelluloseGreyCinderblock - Grey - HA(6)
Non-Fibrous
HomogenousEA3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14635 Bentler St, Detroit, MI 48223
ETL Job :
Client Project :
293125
293125
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/03/2026
08/04/2026
Date Collected :
Date Received :
PLM None Detected 1915233
7A PLM 99% OtherPLM 1% CelluloseGreyMortar / Block - Grey - HA(7)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915234
7B PLM 99% OtherPLM 1% CelluloseGreyMortar / Block - Grey - HA(7)
Non-Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM None Detected 1915235
7C PLM 99% OtherPLM 1% CelluloseGreyMortar / Block - Grey - HA(7)
Non-Fibrous
HomogenousEA3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
PLM 5% Chrysotile1915236
8A PLM 92% OtherPLM 3% CelluloseWhiteCaulk / Exterior - White - HA(8)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/07/2026
1915237
8B
Positive Stop
EA2
Analyst: OJ Ivey
Date Analyzed : 08/07/2026
Sample Not Analyzed
1915238
8C
Positive Stop
EA3
Analyst: OJ Ivey
Date Analyzed : 08/07/2026
Sample Not Analyzed
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14635 Bentler St, Detroit, MI 48223
ETL Job :
Client Project :
293125
293125
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/03/2026
08/04/2026
Date Collected :
Date Received :
PLM None Detected 1915239
9A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(9) Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915240
9B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(9) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915241
9C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(9) Non-Fibrous
HomogenousEA3
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915242
10A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Floor - Grey - HA(10)
Non-Fibrous
HomogenousFS1
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915243
10B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Floor - Grey - HA(10)
Non-Fibrous
HomogenousFS2
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915244
10C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Floor - Grey - HA(10)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14635 Bentler St, Detroit, MI 48223
ETL Job :
Client Project :
293125
293125
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/03/2026
08/04/2026
Date Collected :
Date Received :
PLM None Detected 1915245
11A PLM 100% OtherPLM Trace FiberglassGreyRoofing / Asphalt (Shingles) -
Grey - HA(11) Non-Fibrous
HomogenousEA5
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915246
11B PLM 100% OtherPLM Trace FiberglassGreyRoofing / Asphalt (Shingles) -
Grey - HA(11) Non-Fibrous
HomogenousEA5
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915247
11C PLM 100% OtherPLM Trace FiberglassGreyRoofing / Asphalt (Shingles) -
Grey - HA(11) Non-Fibrous
HomogenousEA5
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915248
12A PLM 100% OtherPLM Trace FiberglassBlackRoofing / Asphalt (Shingles) -
Black - HA(12) Non-Fibrous
HomogenousEA5
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915249
12B PLM 100% OtherPLM Trace FiberglassBlackRoofing / Asphalt (Shingles) -
Black - HA(12) Non-Fibrous
HomogenousEA5
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915250
12C PLM 100% OtherPLM Trace FiberglassBlackRoofing / Asphalt (Shingles) -
Black - HA(12) Non-Fibrous
HomogenousEA5
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
14635 Bentler St, Detroit, MI 48223
ETL Job :
Client Project :
293125
293125
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/03/2026
08/04/2026
Date Collected :
Date Received :
PLM None Detected 1915251
13A PLM 90% OtherPLM 10% CelluloseBlackRoofing / Tar Paper - Black -
HA(13) Fibrous
HomogenousEA5
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915252
13B PLM 90% OtherPLM 10% CelluloseBlackRoofing / Tar Paper - Black -
HA(13) Fibrous
HomogenousEA5
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
PLM None Detected 1915253
13C PLM 90% OtherPLM 10% CelluloseBlackRoofing / Tar Paper - Black -
HA(13) Fibrous
HomogenousEA5
Layer-1 Analyst: Chris Canilao
Date Analyzed : 08/07/2026
Lab Supervisor/Other Signatory
Chris Canilao
OJ Ivey
Analyst:
400 Point Count Results by EPA 600/R-93/116 PLM (denoted by "PC")
Item 198.1: PLM Methods for Identifying and Quantitating Asbestos in Bulk Samples
Item 198.6: PLM Methods for Identifying and Quantitating Asbestos in Non-Friable Organically Bound Bulk Samples
EPA 600/R-93/116: Method for Determination of Asbestos in Bulk Building Materials
EPA 600/M4-82-020: Interim Method for Determination of Asbestos in Bulk Insulation Samples
A % Asbestos result of "Trace" indicates that the analyzed material was found to contain less than 1% asbestos and would not be considered an Asbestos Containing Material (ACM).
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.