140R3025B0002_Attachment_2_-_DWG_M50_STRONGARM_INSTALL_SPECIFICATION.pdf
PDF 704 KB Posted
- Attached to
- K12 Drop-Arm Road Barriers at Davis Dam
- Solicitation number
- 140R3025B0002
About this file
These technical installation drawings detail the HySecurity M50 Strongarm barrier gate system for a 12-foot clear opening. The documentation provides comprehensive installation specifications, including precise measurements for concrete footings, rebar reinforcement, and component placement. Key technical requirements include using #6 rebar (3/4") grade 60 or better, a 72x72x48 inch concrete footing, and specific torque specifications of 150 ft-lbs for bolts. The installation requires multiple components such as hinge posts, catch posts, retainer plates, anchor bolts, nuts, and washers, with part numbers ranging from MX002771 to MX002776.
The drawings specify critical installation guidelines, including centering posts in concrete footings, cutting 2x4 and 2x6 wooden templates to match clear opening width, and removing wood parts after concrete has adequately hardened. Additional installation notes cover conduit placement for various electrical requirements, including provisions for thru beam photo eyes, traffic signals, high and low voltage controls, loop detectors, and earth grounding. The documents include multiple technical views showing the barrier in closed and open positions, with detailed dimensional references for 12-foot clear opening configurations.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WASHER
P/N MX002775
2X4'S CUT TO MATCH
CLEAR OPENING WIDTH
RETAINER PLATE
P/N MX002776
HINGE POST
TEMPLATE
P/N MX002771
ANCHOR BOLT
P/N MX002773
NUT
P/N MX002774
1 2
CATCH POST
TEMPLATE
P/N MX002772
HINGE POST
CATCH POST
CONDUIT
2X6 CUT 2 FT LONGER
THAN CLEAR OPENING WIDTH
RETAINER PLATE
P/N MX002776
1 M50 COMPONENT PARTS: ONLY USE THE HARDWARE PROVIDED
DO NOT SUBSTITUTE WITH OTHER MANUFACTURED PARTS.
TORQUE TO 150 FT-LBS
WOOD PARTS: TEMPLATE, 2X4 AND 2X6 ARE REMOVED AFTER CONCRETE HAS
HARDENED ADEQUATELY.
NOTE: DRAWING IS NOT TO SCALE.
DY 6/6/2012
DATE
DATE
DATE
CHECKED
APPROVED
DRAWN REV
D0495
THIRD ANGLE PROJECTION SHT OF
DOCUMENT NUMBER:
STRONGARM M50 INSTALL
DOCUMENT TITLE
Kent, Washington
LTR DESCRIPTION DATE APPRV'D
05 BOLT TORQUE CORRECTED TO 150 FT-LBS SHEET 1 9/10/2012 DRY
HySecurity
21.5
142.7 (12' ARM)
166.7 (14' ARM)
190.7 (16' ARM)
214.7 (18' ARM)
238.7 (20' ARM)
261.7 (22' ARM)
286.7 (24' ARM)
MOUNTING BOLTS
CENTER TO CENTER
#6 REBAR MAT BOTH
DIRECTIONS (3/4")
GRADE 60 OR BETTER
4,000 PSI MIN CONCRETE TYPICAL
HINGE POST
TEMPLATE
CATCH POST
TEMPLATE
144(12' ARM)
168 (14' ARM)
192 (16' ARM)
216 (18' ARM)
240 (20' ARM)
264 (22' ARM)
288 (24' ARM)
CLEAR OPENING (C.O.)
2X4 CUT LENGTH
25.7
(TO C.O.)
27.6
(TO C.O.)
9.0 OC
9.0 OC
POSTS ARE CENTERED
IN CONCRETE FOOTINGS
2X4'S CUT TO MATCH
CLEAR OPENING WIDTH
2X6 CUT 2 FT LONGER THAN
CLEAR OPENING WIDTH
4. DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED
5. HINGE AND CATCH POST BOLT TEMPLATES ARE DIFFERENT, BUT
CONCRETE FOOTINGS AND REBAR MATS ARE IDENTICAL IN SIZE.
6. ALLOY STEEL ANCHOR BOLTS, EMBEDDED RETAINER PLATES, NUTS
AND WASHERS ARE SUPPLIED BY HYSECURITY
7. REBAR, CONDUIT, 2X4, 2X6, AND CONCRETE MUST BE SUPPLIED BY THE INSTALLER
NOTE: DRAWING IS NOT TO SCALE.
DY 6/6/2012
DATE
DATE
DATE
CHECKED
APPROVED
DRAWN REV
D0495
THIRD ANGLE PROJECTION SHT OF
DOCUMENT NUMBER:
STRONGARM M50 INSTALL
DOCUMENT TITLE
Kent, Washington
LTR DESCRIPTION DATE APPRV'D
48.1
5.3
23.9
12.00
7.00
30.00 7.1
7.1
28.5
SUPPLY & CONTROL
CONDUIT CUTOUT
THRU BEAM PHOTO
EYE CONDUIT CUTOUT10.
HINGE/CONTROL CATCH
CUT OUT FOR CONDUIT WHEN A TRAFFIC SIGNAL
IS MOUNTED ON THE CATCH POST
CENTER POSTS/TEMPLATES
IN CONCRETE FOOTINGS
CONDUIT FOR THRU BEAM PHOTO EYE*
OR OPTIONAL CATCH POST TRAFFIC LIGHT
HIGH VOLTAGE CONDUIT
LOW VOLTAGE CONTROLS CONDUIT
(MUST BE SEPARATE CONDUIT)
CONDUIT FOR LOOPS
EARTH GROUND CONDUIT
10. NECESSARY IF USING THRU BEAM PHOTO EYE, UNLESS OPTIONAL BATTERY
POWERED EYE IS USED
8. DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED
9. REBAR NOT SHOWN
NOTE: DRAWING IS NOT TO SCALE.
DY 6/6/2012
DATE
DATE
DATE
CHECKED
APPROVED
DRAWN REV
D0495
THIRD ANGLE PROJECTION SHT OF
DOCUMENT NUMBER:
STRONGARM M50 INSTALL
DOCUMENT TITLE
Kent, Washington
LTR DESCRIPTION DATE APPRV'D
(C.O.)
49.75
23.2
73.0
27.6 25.7
66.3 + C.O.
MEASURED TO HEAD OF
LOWER ARM BEARING BOLTS
MEASURE TO
GUIDE BEARING
(C.O.)
DIMENSION SHOWN FOR 12' CLEAR OPENING EXAMPLE
NOTE: DRAWING IS NOT TO SCALE.
DY 6/6/2012
DATE
DATE
DATE
CHECKED
APPROVED
DRAWN REV
D0495
THIRD ANGLE PROJECTION SHT OF
DOCUMENT NUMBER:
STRONGARM M50 INSTALL
DOCUMENT TITLE
Kent, Washington
LTR DESCRIPTION DATE APPRV'D
9.0 O.C.
9.0 O.C
#6 REBAR BOTH
DIRECTIONS (3/4")
GRADE 60 OR BETTER
11. DESIGN SHOWN IS FOR A CONCRETE FOOTING 72 X 72X48
REBAR TO BE SPACED 2 INCHES FROM THE TOP OF CONCRETE FOOTING AND 3 INCHES
FROM THE BOTTOM.
12. REBAR AND FOOTING ARE IDENTICAL FOR PIVOT AND CATCH SIDES.
NOTE: DRAWING IS NOT TO SCALE.
DY 6/6/2012
DATE
DATE
DATE
CHECKED
APPROVED
DRAWN REV
D0495
THIRD ANGLE PROJECTION SHT OF
DOCUMENT NUMBER:
STRONGARM M50 INSTALL
DOCUMENT TITLE
Kent, Washington
LTR DESCRIPTION DATE APPRV'D
HySecurity M50 BARRIER CLOSED - 12' CLEAR OPENING SHEET 7
HySecurity M50 BARRIER OPEN - 12' CLEAR OPENING SHEET 8
HySecurity M50 BARRIER OPEN - 12' CLEAR OPENING SHEET 8
| Sheet1 |
| Drawing View6 |
| Sheet2 |
| Drawing View1 |
| Drawing View2 |
| Sheet3 |
| Drawing View3 |
| Drawing View5 |
| Sheet4 |
| Drawing View7 |
| Drawing View8 |
| Sheet5 |
| Drawing View23 |
| Drawing View24 |
| Drawing View26 |
| Sheet6 |
| Drawing View16 |
| Drawing View28 |
| Sheet7 |
| Drawing View20 |
| Sheet8 |
| Drawing View27 |
File details come from the government source that posted it. Updated .