These technical installation drawings detail the HySecurity M50 Strongarm barrier gate system for a 12-foot clear opening. The documentation provides comprehensive installation specifications, including precise measurements for concrete footings, rebar reinforcement, and component placement. Key technical requirements include using #6 rebar (3/4") grade 60 or better, a 72x72x48 inch concrete footing, and specific torque specifications of 150 ft-lbs for bolts. The installation requires multiple components such as hinge posts, catch posts, retainer plates, anchor bolts, nuts, and washers, with part numbers ranging from MX002771 to MX002776.

The drawings specify critical installation guidelines, including centering posts in concrete footings, cutting 2x4 and 2x6 wooden templates to match clear opening width, and removing wood parts after concrete has adequately hardened. Additional installation notes cover conduit placement for various electrical requirements, including provisions for thru beam photo eyes, traffic signals, high and low voltage controls, loop detectors, and earth grounding. The documents include multiple technical views showing the barrier in closed and open positions, with detailed dimensional references for 12-foot clear opening configurations.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WASHER

P/N MX002775

2X4'S CUT TO MATCH

CLEAR OPENING WIDTH

RETAINER PLATE

P/N MX002776

HINGE POST

TEMPLATE

P/N MX002771

ANCHOR BOLT

P/N MX002773

NUT

P/N MX002774

1 2

CATCH POST

TEMPLATE

P/N MX002772

HINGE POST

CATCH POST

CONDUIT

2X6 CUT 2 FT LONGER

THAN CLEAR OPENING WIDTH

RETAINER PLATE

P/N MX002776

1 M50 COMPONENT PARTS: ONLY USE THE HARDWARE PROVIDED

DO NOT SUBSTITUTE WITH OTHER MANUFACTURED PARTS.

TORQUE TO 150 FT-LBS

WOOD PARTS: TEMPLATE, 2X4 AND 2X6 ARE REMOVED AFTER CONCRETE HAS

HARDENED ADEQUATELY.

NOTE: DRAWING IS NOT TO SCALE.

DY 6/6/2012

DATE

DATE

DATE

CHECKED

APPROVED

DRAWN REV

D0495

THIRD ANGLE PROJECTION SHT OF

DOCUMENT NUMBER:

STRONGARM M50 INSTALL

DOCUMENT TITLE

Kent, Washington

LTR DESCRIPTION DATE APPRV'D

05 BOLT TORQUE CORRECTED TO 150 FT-LBS SHEET 1 9/10/2012 DRY

HySecurity

21.5

142.7 (12' ARM)

166.7 (14' ARM)

190.7 (16' ARM)

214.7 (18' ARM)

238.7 (20' ARM)

261.7 (22' ARM)

286.7 (24' ARM)

MOUNTING BOLTS

CENTER TO CENTER

#6 REBAR MAT BOTH

DIRECTIONS (3/4")

GRADE 60 OR BETTER

4,000 PSI MIN CONCRETE TYPICAL

HINGE POST

TEMPLATE

CATCH POST

TEMPLATE

144(12' ARM)

168 (14' ARM)

192 (16' ARM)

216 (18' ARM)

240 (20' ARM)

264 (22' ARM)

288 (24' ARM)

CLEAR OPENING (C.O.)

2X4 CUT LENGTH

25.7

(TO C.O.)

27.6

(TO C.O.)

9.0 OC

9.0 OC

POSTS ARE CENTERED

IN CONCRETE FOOTINGS

2X4'S CUT TO MATCH

CLEAR OPENING WIDTH

2X6 CUT 2 FT LONGER THAN

CLEAR OPENING WIDTH

4. DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

5. HINGE AND CATCH POST BOLT TEMPLATES ARE DIFFERENT, BUT

CONCRETE FOOTINGS AND REBAR MATS ARE IDENTICAL IN SIZE.

6. ALLOY STEEL ANCHOR BOLTS, EMBEDDED RETAINER PLATES, NUTS

AND WASHERS ARE SUPPLIED BY HYSECURITY

7. REBAR, CONDUIT, 2X4, 2X6, AND CONCRETE MUST BE SUPPLIED BY THE INSTALLER

NOTE: DRAWING IS NOT TO SCALE.

DY 6/6/2012

DATE

DATE

DATE

CHECKED

APPROVED

DRAWN REV

D0495

THIRD ANGLE PROJECTION SHT OF

DOCUMENT NUMBER:

STRONGARM M50 INSTALL

DOCUMENT TITLE

Kent, Washington

LTR DESCRIPTION DATE APPRV'D

48.1

5.3

23.9

12.00

7.00

30.00 7.1

7.1

28.5

SUPPLY & CONTROL

CONDUIT CUTOUT

THRU BEAM PHOTO

EYE CONDUIT CUTOUT10.

HINGE/CONTROL CATCH

CUT OUT FOR CONDUIT WHEN A TRAFFIC SIGNAL

IS MOUNTED ON THE CATCH POST

CENTER POSTS/TEMPLATES

IN CONCRETE FOOTINGS

CONDUIT FOR THRU BEAM PHOTO EYE*

OR OPTIONAL CATCH POST TRAFFIC LIGHT

HIGH VOLTAGE CONDUIT

LOW VOLTAGE CONTROLS CONDUIT

(MUST BE SEPARATE CONDUIT)

CONDUIT FOR LOOPS

EARTH GROUND CONDUIT

10. NECESSARY IF USING THRU BEAM PHOTO EYE, UNLESS OPTIONAL BATTERY

POWERED EYE IS USED

8. DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED

9. REBAR NOT SHOWN

NOTE: DRAWING IS NOT TO SCALE.

DY 6/6/2012

DATE

DATE

DATE

CHECKED

APPROVED

DRAWN REV

D0495

THIRD ANGLE PROJECTION SHT OF

DOCUMENT NUMBER:

STRONGARM M50 INSTALL

DOCUMENT TITLE

Kent, Washington

LTR DESCRIPTION DATE APPRV'D

(C.O.)

49.75

23.2

73.0

27.6 25.7

66.3 + C.O.

MEASURED TO HEAD OF

LOWER ARM BEARING BOLTS

MEASURE TO

GUIDE BEARING

(C.O.)

DIMENSION SHOWN FOR 12' CLEAR OPENING EXAMPLE

NOTE: DRAWING IS NOT TO SCALE.

DY 6/6/2012

DATE

DATE

DATE

CHECKED

APPROVED

DRAWN REV

D0495

THIRD ANGLE PROJECTION SHT OF

DOCUMENT NUMBER:

STRONGARM M50 INSTALL

DOCUMENT TITLE

Kent, Washington

LTR DESCRIPTION DATE APPRV'D

9.0 O.C.

9.0 O.C

#6 REBAR BOTH

DIRECTIONS (3/4")

GRADE 60 OR BETTER

11. DESIGN SHOWN IS FOR A CONCRETE FOOTING 72 X 72X48

REBAR TO BE SPACED 2 INCHES FROM THE TOP OF CONCRETE FOOTING AND 3 INCHES

FROM THE BOTTOM.

12. REBAR AND FOOTING ARE IDENTICAL FOR PIVOT AND CATCH SIDES.

NOTE: DRAWING IS NOT TO SCALE.

DY 6/6/2012

DATE

DATE

DATE

CHECKED

APPROVED

DRAWN REV

D0495

THIRD ANGLE PROJECTION SHT OF

DOCUMENT NUMBER:

STRONGARM M50 INSTALL

DOCUMENT TITLE

Kent, Washington

LTR DESCRIPTION DATE APPRV'D

HySecurity M50 BARRIER CLOSED - 12' CLEAR OPENING SHEET 7

HySecurity M50 BARRIER OPEN - 12' CLEAR OPENING SHEET 8

HySecurity M50 BARRIER OPEN - 12' CLEAR OPENING SHEET 8

Sheet1
Drawing View6
Sheet2
Drawing View1
Drawing View2
Sheet3
Drawing View3
Drawing View5
Sheet4
Drawing View7
Drawing View8
Sheet5
Drawing View23
Drawing View24
Drawing View26
Sheet6
Drawing View16
Drawing View28
Sheet7
Drawing View20
Sheet8
Drawing View27

File details come from the government source that posted it. Updated .