This specification document outlines requirements for plug valves and strainers to be provided to the Bureau of Reclamation at the Grand Coulee Dam Right Powerhouse. Thirty-six plug valves in sizes of 12 inches and 14 inches are required, along with eighteen strainers of the same sizes. The valves must isolate the strainers and regulate untreated river water routed into the generator cooling system. Technical specifications are provided for the valve and strainer materials, pressure ratings, connections, coatings, actuators, and standards. Successful offerors must deliver all items to the specified delivery address within thirty-six weeks of order receipt. The related solicitation is for these Right Powerhouse valves and strainers with opportunity number 140R1022Q0005 issued by the Department of the Interior Bureau of Reclamation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
140R1022Q0005
RPH Valves and Strainers
Continuation of 1449 Block 20, Schedule of Supplies/Services
Main Unit Generator Cooling Water High Pressure Strainers & Valves
Grand Coulee Dam
Procurement Specifications
The purpose of this specification is to procure thirty-six (36) Plug Valves and eighteen (18)
Basket Strainers for the Right Powerhouse (RPH) Main Units. These valves serve to isolate strainers as required for maintenance. The strainers serve to strain raw river water to be routed into the generator cooling water system.
Line 10: 12” Plug Valve Salient Characteristics:
• Size: 12 Inch
• Quantity: 24
• Media: Unfiltered River Water
• Valve Type: Plug (Port or Eccentric)
• Pressure Rating: 175 PSIG Max Working Pressure
• End Connections: Flanged (ANSI Class 125)
• Control Features: Worm Gear Actuator & Handwheel
• Sealing Element: Ductile Iron/Buna‐N Plug
• Body Material: Ductile Iron
• Industry Standards:
o Body & Cover Ductile Iron: ASTM A536 Grade 65‐45‐12 o Flange Dimensions ASME B16.1 CLASS 125
• Trim Material o Seat Ring Hardfaced Nickel o Bearings Permanently Lubricated 316 Stainless Steel o Thrust Washers PTFE (Teflon) o Bonnet Seal O‐ring
• Coating System (Internal & External): 2 Part Epoxy, minimum 6 mil Thick
Line 20: 14” Plug Valve Salient Characteristics:
• Size: 14 Inch
• Quantity: 12
• Media: Unfiltered River Water
• Valve Type: Plug (Port or Eccentric)
• Pressure Rating: 175 PSIG Max Working Pressure
• End Connections: Flanged (ANSI Class 125)
• Control Features: Worm Gear Actuator & Handwheel
• Sealing Element: Ductile Iron/Buna‐N Plug
• Body Material: Ductile Iron
• Industry Standards:
D-2 o Body & Cover Ductile Iron: ASTM A536 Grade 65‐45‐12 o Flange Dimensions ASME B16.1 CLASS 125
• Trim Material o Seat Ring Hardfaced Nickel o Bearings Permanently Lubricated 316 Stainless Steel o Thrust Washers PTFE (Teflon) o Bonnet Seal O‐ring
• Coating System (Internal & External): 2 Part Epoxy, minimum 6 mil Thick
Line 30: 12” Strainer Salient Characteristics:
• Size: 12 Inch
• Quantity: 12
• Media: Unfiltered River Water
• Strainer Type: Simplex Basket
• Screen Opening: 1/8 (0.125) Inch
• Pressure Rating: 175 PSIG Max Working Pressure
• Flanged Ends: ASME B16.1 CLASS 125
• Basket Material: 304 Stainless Steel
• Body Material: Ductile Iron or Carbon Steel with a coating system that provides a minimum 30-year service life against corrosion from raw river water.
• Location Constraints: (See image below of existing equipment; flow is left to right) o Each Generator has two parallel 12” pipelines to be fitted with simplex strainer.
o Both Water pipe centerlines are horizontal orientation parallel to concrete wall.
o Both Water pipe centerlines are 30” from concrete wall.
o Bottom pipe centerline is 43” from concrete floor.
o Top Pipe Centerline is 75½” from concrete floor.
o Strainers to be located at same horizontal position along pipe centerlines.
• Note: If Body orientation is angled (about the pipe centerline), a means to completely drain must be provided.
• Trim Material o Hinged Lid (Right‐Hand Opening) o Quick‐Open Eye Bolts
Line 40: 14” Strainer Salient Characteristics:
• Size: 14 Inch
• Quantity: 6
• Media: Unfiltered River Water
• Strainer Type: Simplex Basket
• Screen Opening: 1/8 (0.125) Inch
D-3
• Pressure Rating: 175 PSIG Max Working Pressure
• Flanged Ends: ASME B16.1 CLASS 125
• Basket Material: 304 Stainless Steel
• Body Material: Ductile Iron or Carbon Steel with a coating system that provides a minimum 30-year service life against corrosion from raw river water.
• Location Constraints: (See image below of existing equipment; flow is left to right) o Each Generator has two parallel 14” pipelines to be fitted with simplex strainer.
o Both Water pipe centerlines are horizontal orientation parallel to concrete wall.
o Both Water pipe centerlines are 30” from concrete wall.
o Bottom pipe centerline is 43” from concrete floor.
o Top Pipe Centerline is 75½” from concrete floor.
o Strainers to be located at same horizontal position along pipe centerlines.
• Note: If Body orientation is angled (about the pipe centerline), a means to completely drain must be provided.
• Trim Material o Hinged Lid (Right‐Hand Opening) o Quick‐Open Eye Bolts
D-4
Figure 1 existing plug valve and strainer configuration
Delivery Terms: F.O.B. Destination.
Delivery Date: Thirty-six (36) weeks after receipt of order (ARO).
Delivery Address:
Bureau of Reclamation - PN – GCPO
Grand Coulee – Receiving
Hwy 155 - Warehouse B - Door – 6
Industrial Area
Grand Coulee, WA 99133
Warranty: Standard Manufacturer's Warranty