B08_Attachment_4_-_Devices_at_Amend_01_0001.pdf
PDF 3 MB Posted
- Attached to
- FIRE ALARM & Devices Install - Klondike Gold Rush Federal contract opportunity
- Solicitation number
- 140P9725Q0052
About this file
This document is a comprehensive technical specification for Honeywell Silent Knight fire alarm and detection devices, specifically focusing on several product lines including photoelectric smoke detectors, heat detectors, wireless modules, notification appliances, and manual pull stations. The technical specifications provide detailed information on product features, compatibility, electrical and environmental specifications, agency listings, and ordering information for various models such as SK-PHOTO, SK-PHOTO-T, SK-PHOTOR, SK-HEAT, WAM-MM, WAM-RC, SK-PULL, and L-Series notification devices.
Key technical details include operating voltage ranges (typically 15-32VDC), operating temperature ranges (32°F to 120°F), battery specifications (often using CR-123A batteries with 2-year life), and compatibility with multiple Honeywell Silent Knight fire alarm control panels. The devices are designed for commercial and institutional applications, with features like addressable communication, wireless mesh networking, frequency hopping, bi-directional communications, and UL/FM/CSFM certifications. The product lines offer flexibility in installation, with options for wired and wireless configurations, various mounting bases, and configurations to suit different environmental and detection requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P9725Q0052_Amd_0002.pdf | ||
| B09_Amend_02_-_Q_As_0002.pdf | ||
| Sol_140P9725Q0052_Amd_0001.pdf | ||
| Sol_140P9725Q0052.pdf | ||
| B08_Attachment_2__Photos.pdf | ||
| B08_Attachment_1__Fire_Protection_Plans.pdf | ||
| B08_Attachment_3__Drawings.pdf | ||
| B08_Attachment_5__Moore_Inventory.xls | XLS spreadsheet | |
| B03_Attachment_9_DOL_WD_2015-5685_Rev_24.pdf | ||
| B08_Attachment_7_-_Submittal_Form_CM-16.pdf | ||
| B08_Attachment_4_-_Devices.pdf | ||
| B08_Attachment_8_-_Scope_of_Work.pdf | ||
| B08_Attachment_6__Maintenance_Inventory.xls | XLS spreadsheet |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F E AT U R E S & B E NE F I T S
• Sleek, low-profile design
• Base included
• Reliable analog communications for trouble-free operation
• Age resistant polymer housing
• Dual electronic thermistor design on the SK-Photo-T
• Superior EMI resistance for reliability
• Simple field cleaning for code compliance
• Variety of mounting options to meet any application
• Dual LED indicators for 360º visibility
• Detector transmits signal to indicate maintenance is required
• Optional remote LED annunciator (System Sensor® PN RA100Z)
• Plug-in mounting provides ease of installation
• Tamper-proof feature available on mounting bases
• Listed for use in duct applications
• Rotary address switches for fast installation
• UL Listed
• FM Approved
SK-PHOTO, SK-PHOTO-T, and
SK-PHOTOR
Intelligent Photoelectric Smoke Detectors
The SK-PHOTO is a photoelectric smoke detector, the SK PHOTO-T is a photoelectric smoke detector with thermal and SK-PHOTOR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with the Honeywell Silent Knight series fire alarm control panels (FACPs).
SK-PHOTO and SK-PHOTO-T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector’s address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels.
SK-PHOTO and SK-PHOTO-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK-PHOTO-T, dual electronic thermistors add 135ºF (57ºC) thermal technology to maximize detection.
The SK-PHOTOR is a remote test capable detector for use with the DNR/
DNRW duct smoke detector (not included).
COMPATIBILITY
SK-Photo, and SK-Photo-T are compatible with the following detector bases:
B210LP: 6” base (included) B501: 2 wire base B224RB: Relay base B224BI: Isolator base
SK-PHOTO (BASE INCLUDED)
For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com.
Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation.
Silent Knight®, System Sensor® and Honeywell® are registered trademarks of Honeywell International, Inc.
This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice.
For Technical Support, call 800-446-6444.
SK-PHOTO, SK-PHOTO-T and SK-PHOTOR Technical Specifications
PHYSICAL
Height: 2.0” (5.0 cm) Diameter: 4.1” (10.4 cm) installed in B501 base
ELECTRICAL
Operating Voltage: 15–32VDC Standby Current: 300 μA @ 24VDC Maximum Alarm Current: 6.5mA @ 24VDC max (with LED on)
ENVIRONMENTAL
Operating Temperature SK-Photo: 32º – 120ºF (0ºC – 49ºC) SK-Photo-T: 32º – 100ºF (0ºC – 38ºC) Humidity: 10% – 93% non-condensing
OTHER RATINGS
SK-Photo-T Thermal: Fixed temperature set point 135ºF (57ºC) Velocity: 0 – 4000 fpm (0 – 20 m/sec)
INSTALLATION
The SK-PHOTO and SK-PHOTO-T plug into a compatible Silent Knight series detector bases. The SK-PHOTOR is a remote test capable detector head included within the DNR (W) duct smoke detector.
ORDERING INFORMATION
SK-PHOTO: Photoelectric smoke detector SK-PHOTO-T: Photoelectric smoke detector with thermal (135°F fixed temperture) SK-PHOTOR: Photoelectric detector with remote test capability
ACCESSORIES
RA100Z: Remote LED annunciator XR2B: Detector removal tool. A removal and replacement tool for SK series plug-in detectors.
Includes the T55-127-000 M02-04-01: Detector test magnet.
M02-09-00: Test magnet with telescoping handle XP-4: Extension Pole for XR2B. Extends from 5 – 15 ft.
T55-127-000: Detector Removal Head BCK-200B: Black Detector Kit. For SK series detectors
COMPATIBILITY
The SK-PHOTO, SK-PHOTO-T and SK-PHOTOR are compatible with the following Honeywell Silent Knight fire alarm control panels:
6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency mass notification system.
6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency mass notification system.
Doc 350118 | Rev G | 11/17 © 2017 Honeywell International Inc.
For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com
Honeywell Silent Knight 12 Clintonville Road
Northford, CT 06472
800-328-0103
HEAT DETECTORS
SK-HEAT Addressable Heat And Rate-Of-Rise Detector SK-HEAT addressable heat and rate-of-rise detectors are plug-in thermal detectors with integral communication features that surpass conventional detectors.
Overview
SK-HEAT addressable heat and rate-of-rise detectors are plug-in thermal detectors with integral communication features that surpass conventional detectors. These thermal detectors are for use with the Honeywell Silent Knight® Series fire alarm control panels (FACPs). SK-HEAT detectors are intelligent sensors that utilize a state-of-the-art thermistor sensing circuits for fast response times. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector’s address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels.
Features & Benefits:
Reliable analog communications for trouble-free operation
Age resistant polymer housing
Innovative thermistor sensing circuit
Superior EMI resistance for reliability
Variety of mounting options to meet any application
Dual LED indicators for 360º visibility
Detector transmits signal to indicate maintenance is required
Plug-in mounting provides ease of installation
Rotary address switches for fast installation
Certifications:
UL
Product Number
Fe ed ba ck https://buildings.honeywell.com/us/en/home https://buildings.honeywell.com/us/en/home https://buildings.honeywell.com/pif/cwa/oauth/request/j_security_check?resource=https://buildings.honeywell.com/us/en/products/by-category/fire-life-safety/sensors-and-detectors/intelligent-detectors/heat-detectors/sk-heat-addressable-heat-and-rate-of-rise-detector?pdpPageTab=pills-sku-tab&appId=78
Please sign in to view part numbers available for purchase based on your account Sign In
SK-HEAT-HT-W
Fixed Thermal Detector: High Temperature 190 F, White
SK-HEAT-ROR-W
Fixed Thermal Detector: Rate of Rise: 135 F, White
SK-HEAT-W
Fixed Thermal Detector: Addressable, White
Fe ed ba ck https://buildings.honeywell.com/pif/cwa/oauth/request/j_security_check?resource=https://buildings.honeywell.com/us/en/products/by-category/fire-life-safety/sensors-and-detectors/intelligent-detectors/heat-detectors/sk-heat-addressable-heat-and-rate-of-rise-detector?pdpPageTab=pills-sku-tab&appId=78 https://buildings.honeywell.com/pif/cwa/oauth/request/j_security_check?resource=https://buildings.honeywell.com/us/en/products/by-category/fire-life-safety/sensors-and-detectors/intelligent-detectors/heat-detectors/sk-heat-addressable-heat-and-rate-of-rise-detector?pdpPageTab=pills-sku-tab&appId=78
Intelligent Wireless Devices
WSK-WGI
SWIFT® Wireless Gateway
The SWIFT® (Smart Wireless Integrated Fire Technology) Wireless System can be applied in many situations that are problematic for traditional wired devices. In cases where areas of a building are difficult or impossible to wire, visually sensitive, or have restricted access, SWIFT wireless sensors provide an efficient, reliable solution.
SWIFT wireless devices communicate via a proprietary wireless mesh protocol to communicate with a Silent Knight® fire alarm system by means of a SWIFT wireless gateway. The SWIFT gateway connects to the SLC loop of a 6700, 6808, 6820/EVS panel using SK protocol. New type IDs for wireless devices are supported that allow the FACP to display all events such as alarms and trouble indications, as well as unique trouble conditions required for wireless devices. This capability eliminates the need for a supplementary annunciator for wireless event messages.
Wireless devices in a SWIFT network develop “parent-child” communication links with other devices in the mesh, so that a message originating from a remote device “hops” to the closest parent device, and then to successive parent devices until the message reaches gateway. Alternate paths are also identified and supervised by the SWIFT protocol providing approved Class A wireless communication. If a device does not have an established communication path with adequate signal strength, an additional device such as a wireless module may be installed in between so that it will act as a repeater.
A SWIFT gateway system supports up to 50 devices: 1 SWIFT gateway and up to 49 wireless detectors, modules, pullstations, and A/V bases. The maximum number of gateways on a system is limited by the number of available SLC addresses on the
FACP, or a maximum of 4 gateways within common wireless range.
FEATURES & BENEFITS
• Wireless mesh technology (902-928 MHz frequency)
• Any wireless device can be added to act as a repeater
• Cascading-wave mesh operation provides a verification of redundant communication paths
• Each SWIFT gateway system supports up to 50 devices: 1 wireless gateway and up to 49 devices
• Standard “code wheel” for setting the SLC address
• Up to 4 wireless networks can be installed with overlapping radio network coverage
• Site Survey feature allows for an evaluation of a site before the installation
• Wireless devices use
(4) CR-123A lithium batteries
• Battery Life – UL listed for 2 years
Page 2 of 4 — 351618:B • 10/3/2018
The SWIFT system has been designed so that it can be installed using only typical hand tools and magnets. However, the SWIFT Tools PC utility provides many benefits that can enhance the process of performing a site evaluation (Site Survey), installing a system (Mesh
Configuration), or extracting detailed information from the system
(Diagnostics). The utility runs on a Windows® laptop, and uses a USB radio antenna (W-USB) inserted into a USB slot to communicate with wireless devices within range of the PC. Once devices have formed a mesh, SWIFT Tools can provide current information on all devices in the mesh as long as the PC is within range of the SWIFT Gateway.
The result is a fire system that combines both wired and wireless detection and presents all event information at the panel and/or network displays, when used.
Compatible Control Panels
• 6700
• 6808
• 6820
• 6820EVS
SWIFT Tools SWIFT Tools is a Windows PC-based utility that is used for site evaluation, system configuration, and diagnostics. The SWIFT Tools program is used with the W-USB adapter to communicate with wireless devices that are not joined in a network, or with one or more wireless gateways and all devices that have formed a network with each gateway. A graphic representation of the wireless network provides important system data in an effective format, including communication links, signal strength, battery voltage, and more.
Tool-less operation is supported, allowing you to perform site evaluation and system configuration and installation can be accomplished without using SWIFT Tools when necessary. Multi-colored LEDs on SWIFT devices provide feedback for interactions. At any point, only one instance of SWIFT Tools can run on a laptop or PC.
SWIFT Tools has the following utilities:
• Site Survey
• Create Mesh Network
• Diagnostics
SWIFT Tools works in a wireless environment with the WSK-WGI and devices within a range of approximately 20 feet.
SWIFT Tools is designed for systems running Microsoft® Windows®.
Minimum System Requirements Operating System: Windows 7 and Windows 8 (32 bit and 64 bit).
Hard Drive: 20 GB hard drive space with minimum 1GB free space on hard disk.
RAM: Minimum 512MB RAM.
Processor speed: 1GHz minimum (2.4 GHz recommended)
Processor, 512K Cache.
SWIFT Components and Ordering Information
• WSK-WGI: Wireless SWIFT Gateway - 1 SWIFT Gateway is required for each wireless mesh, and supports up to 49 SWIFT detectors or modules. Connects to the SLC loop of a compatible panel using SK protocol. Power may be supplied by the SLC circuit or via an optional 24VDC input.
Note: Use of the 24VDC input may be more convenient for service as it allows for powering down a gateway without shutting down an SLC loop.
• WSK-PHOTO: Intelligent, wireless photo detector. Ships with
B501W base included. Requires (4) CR-123A batteries (included).
• WSK-HEAT-ROR: Intelligent wireless rate of rise (135°) heat detector. Ships with B501W base included. Requires (4) CR-123A batteries (included).
• WSK-PHOTO-T: Intelligent wireless photo/heat detector. Ships with B501W base included. Requires (4) CR-123A batteries
(included).
• WSK-HEAT: Intelligent wireless fixed-temperature (135°) heat detector. Ships with B501W base included. Requires (4) CR-123A batteries (included).
• WSK-MONITOR: Wireless monitor module. Used to monitor devices with mechanical contact actuation. Includes a special cover with a built- in tamper magnet. Recommended for installation in a SMB500-WH box (ordered separately) rather than a metal backbox for best performance. Requires (4) CR-123A batteries (included).
• WSK-RELAY: Wireless relay module for use with the WSK-WGI wireless gateway. Includes a special cover with a built-in tamper magnet. Recommended for installation in an SMB500-WH box
(ordered separately) rather than a metal backbox for best performance. Requires (4) CR-123A batteries (included).
• WSK-PULL-DA: Wireless addressable pullstation. Requires (4)
CR-123A batteries (included).
• WAV-CRL, WAV-CWL: SWIFT Wireless Addressable A/V bases.
Requires (8) CR-123A batteries (included). Requires a non-compact ceiling System Sensor® L-series notification device
(ordered separately).
• W-SYNC: Wireless sync module. Requires (4) CR-123A batteries
(included).
• SMB500-WH: Optional surface-mount backbox.
• SWIFT Tools: Programming and diagnostic utility. Free download from www.silentknight.com. For installation on a (typically laptop)
PC running an approved version of Windows (See Minimum
Page 3 of 4 — 351618:B • 10/3/2018
System Requirements for SWIFT Tools). Requires the W-USB radio/ antenna dongle for communication with SWIFT Wireless devices.
• W-USB: Wireless USB radio/antenna dongle that plugs into the
USB port of a PC running SWIFT Tools. The W-USB provides a communication link with SWIFT Wireless devices that are within approximately 20 feet and have not formed a mesh. Alternately, when the devices have formed a mesh, bringing the PC/W-USB within range (20 ft.) of the gateway for that mesh will allow SWIFT
Tools to acquire information on all devices in that mesh, including point-to-point signal strength for all links.
• W-BATCART: Wireless battery cartridge, 10-pack. For use with the wireless pullstations and A/V bases.
WSK-WGI Technical Specifications
351618 | B | 10/18 ©2018 Honeywell International Inc.
Silent Knight®, System Sensor®, and SWIFT® are registered trademarks of Honeywell International Inc.
Microsoft® and Windows® are registered trademarks of Microsoft Corporation.
Duracell® is a registered trademark of Duracell U.S.
Operations Inc. Panasonic® is a registered trademark of Panasonic Corporation.
©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.
This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
Country of origin: Mexico
Honeywell Silent Knight 12 Clintonville Road
Northford, CT 06472-1610
203.484.7161 www.silentknight.com
PHYSICAL
Height: 1 7/8” (4.5 cm) Diameter: 7 7/8” (20 cm)
OPERATING
Operating Temperature Range: 32°F to 120°F (0°C to 49°C) Operating Humidity Range: 10% to 93% non-condensing
ELECTRICAL
External Supply Electrical Ratings: 18V - 30VDC SLC Electrical Ratings: 15V - 30VDC Maximum ambient noise level: -85 dBM Minimum signal strength level for trouble report: -55 dBM Maximum RF power output: +17 dbM Radio Frequency: 902-928 Hhz (lower ISM band)
VW-GATE:
Maximum current (when powered by 24VDC): 40 mA Maximum current (when powered by SLC): 24 mA
VW-DIS-D:
Maximum current: 30 mA Maximum SLC resistance: 50 ohms
AGENCY LISTINGS AND APPROVALS
The listings and approvals below apply to the WSK-WGI. In some cases, certain modules may not be listed by certain approval agencies or listing may be in process. Consult factory for latest listing status.
UL Listed: S3511
CSFM: 7300-0559:0510
FM Approved
FCC ID: PV3WFSGW
STANDARDS AND CODES
The SWIFT Wireless System complies with the following UL Standards and with NFPA 72 Fire Alarm system requirements.
UL 864
UL 268
SPDS902-01 • 7/29/2020 • Page 1
The SWIFT AV bases (WAV-CRL, WAV-CWL, WAV-RL and WAV-WL) are intended for use with compatible System Sensor L-Series AV notification appliances to meet a comprehensive range of notification requirements. The AV Base provides power for the audio and visual signals and supports wireless communication with the Fire Alarm Control Panel (FACP). The L-Series AV notification appliance is mounted directly to the wireless AV base allowing flexibility in color, placement and signal output.
Power is supplied through two sets of 4 batteries – one set provides power for wireless communication, and the other set provides power for the notification appliance’s audio and/or visual signal. Battery life of the wireless portion is UL listed for at least 2 years. Battery life for the AV set of batteries depends upon the activation time and output level of the audio or visual signal. The AV base boosts output voltage to support 24VDC options on connected devices.
The SWIFT synchronization module (W-SYNC) can be used to provide audio and visual synchronization between SWIFT notification appliances and System Sensor wired notification appliances. The wireless synchronization module operates from 24V power with supplemental battery support and communicates through the mesh network to the gateway and FACP. Synchronization is only available with notification appliances that use the System Sensor synchronization protocol. Synchronization of the SWIFT notification appliances within a single mesh network is inherent in the wireless system and a wireless synchronization module is not needed.
The W-SYNC also provides wireless control and monitoring of a Notification Appliance Circuit (NAC) expander or power supply.
SWIFT SYSTEM OVERVIEW
The SWIFT Smart Wireless Integrated Fire Technology wireless system offers intelligent (addressable) devices which provide secure, reliable communication to the Fire Alarm Control Panel (FACP) across a Class A mesh network. Wireless devices create an opportunity for applications where it is costly (concrete walls/ceilings, buried wires), obtrusive (surface mount conduit), or possibly dangerous
Features
• Wireless installation
• Class A mesh network
• Addressable code wheels
• Commercial applications
• Listed to UL 464, UL 1638, UL 1971, ULC S525, and ULC S526
• Frequency hopping
• Bi-Directional Communications
SWIFT AV Base
The System Sensor SWIFT® Wireless system offers an AV base to support L-Series devices in wireless installations.
Agency Listings
7300-1653:0513S4011 3062564
SPDS902-01 • 7/29/2020 • Page 2
Specifications Physical/Operating Specifications
Dimensions (Ceiling) Diameter 7.4” (19 cm); Depth 1.6” (4 cm) Weight (Ceiling): 20.0 oz (567 g) installed with 8 batteries Dimensions (Wall) Height 6” (15 cm); Width 5.1” (13 cm); Depth 1.6” (4 cm) Weight (Wall) 17.6 oz (499 g) installed with 8 batteries
Electrical Specifications
RF Operating Voltage Range 3.3 VDC RF Maximum Current Draw 5 mA (LED On) RF Operating Voltage 12 VDC AV Output, Operating Voltage 24 VDC (nominal) AV Maximum Standby Current 6.5 mA AV Maximum Alarm Current 550 mA Standby Current 210 µA @ 3.3 VDC (LED blink enabled) Maximum Transmit RF Power 17 dBm Radio Frequency Range 902-928 MHz Operating Humidity Range 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range 32°F to 120°F (0°C to 49°C) Battery Type 8 Panasonic CR123A or 8 Duracell DL123A Battery Life RF batteries: 2 year minimum.
AV batteries: See Table 2 for AV battery life.
Battery Replacement Replace during annual maintenance or when TROUBLE BATTERY LOW displays.
AV Battery Life at Temporal 3, Ambient Conditions
Model Model Type
Battery Life (Hour, Minutes), per Candela Setting 15 cd 30 cd 75 cd 95 cd 110 cd 115 cd 135 cd 150 cd 177 cd 185 cd
Chime-only Wall 127h 23m — — — — — — — — — Ceiling — — — — — — — — — —
Horn-only Wall 31h 51m — — — — — — — — — Ceiling — — — — — — — — — —
Strobe-only Wall 20h 44m 14h 09m 8h 20m 7h 22m 6h 02m — 5h 11m — — 4h 01m Ceiling 21h 45m 14h 09m 8h 02m 6h 39m — 5h 39m — 4h 43m 3h 57m —
Chime-Strobe Wall 18h 12m 12h 55m 7h 58m 6h 31m 5h 18m — 4h 26m — — 3h 37m Ceiling 18h 35m 12h 44m 7h 41m 6h 28m — 5h 24m — 4h 29m 3h 45m —
Horn-Strobe Wall 16h 31m 12h 03m 7h 22m 6h 17m 5h 30m — 4h 33m — — 3h 38m Ceiling 12h 34m 9h 54m 6h 14m 5h 24m — 4h 46m — 4h 07m 3h 31m —
Low-Freq.
Sounder-Only
Wall 8h 15m — — — — — — — — — — Ceiling 8h 15m — — — — — — — — — —
Low-Freq.
Sounder- Strobe
Wall — 9h 6m 7h 45m 5h 39m 4h 56m 4h 54m - 4h 12m — — 3h 18m
NOTE: Battery life will decrease using continuous tone or other coded patterns and under non-ambient environmental conditions.
(asbestos) to use traditional wired devices. It allows fast installation for time-critical situations and provides the flexibility to add wireless onto wired systems for retrofit installations. Both wired and wireless devices can be present on the same FACP for an integrated solution.
The mesh network within the SWIFT system creates a child-parent relationship between the devices so that each device has two parents providing a second path for communications on every device. If one device can no longer operate for any reason, the rest of the devices can still communicate with each other, directly or through one or more intermediate devices. Once an initial mesh network is formed, mesh restructuring automatically occurs to find the strongest paths possible within the network.
The SWIFT system also engages frequency hopping to prevent system interference whether intentional or accidental. Each device complies with part 15 of the FCC rules: 1) The device may not cause harmful interference and 2) The device must accept any interference received including interference that may cause undesired operation.
SPDS902-01 • 7/29/2020 • Page 3
System Sensor L-Series AV Devices Model (UL listed)
Model (ULC listed) Description
CHRL CHRLA* Chime Red Wall CHSCRL CHSCRLA* Chime/Strobe Red Ceiling
CHSCRLA-E Chime/Strobe Red Ceiling, English
CHSCRLA-F Chime/Strobe Red Ceiling, French
CHSCWL CHSCWLA* Chime Strobe White Ceiling CHSCWLA-E Chime/Strobe White Ceiling, English CHSCWLA-F Chime/Strobe White Ceiling, French CHSRL CHSRLA* Chime Strobe Red Wall
CHSRLA-E Chime/Strobe Red Wall, English
CHSRLA-F Chime/Strobe Red Wall, French
CHSWL CHSWLA Chime Strobe White Wall CHSWLA-E Chime/Strobe White Wall, English CHSWLA-F Chime/Strobe White Wall, French CHWL CHWLA Chime White Wall HCRL-LF HCRLA-LF† 520Hz Sounder Red Ceiling HRL HRLA Horn Red Wall HRL-LF HRLA-LF† 520Hz Sounder Red Wall HCWL-LF HCWLA-LF† 520Hz Sounder White Ceiling HWL HWLA Horn White Wall HWL-LF HWLA-LF† 520Hz Sounder White Wall P2RL P2RLA* Horn/Strobe 2-wire Red Wall
P2RLA-E Horn/Strobe 2-wire Red Wall, English
P2RLA-F Horn/Strobe 2-wire Red Wall, French
P2RL-LF P2RLA-LF† 520Hz Sounder/Strobe Red Wall
P2RL-P P2RLA-P Horn Strobe 2-wire Red Wall, Plain
P2RL-SP — Horn Strobe 2-wire Red Wall, Fuego
P2WL P2WLA Horn Strobe 2-wire White Wall P2WLA-E Horn/Strobe 2-wire White Wall, English P2WLA-F Horn/Strobe 2-wire White Wall, French
Model (UL listed)
Model (ULC listed) Description
P2WL-LF P2WLA-LF† 520Hz Sounder/Strobe White Wall
P2WL-P P2WLA-P Horn Strobe 2-wire White Wall, Plain
P2WL-SP — Horn Strobe 2-wire White Wall, Fuego
PC2RL PC2RLA* Horn Strobe 2-wire Red Ceiling PC2RLA-E Horn/Strobe 2-wire Red
Ceiling, English PC2RLA-F Horn/Strobe 2-wire Red
Ceiling, French PC2WL PC2WLA* Horn Strobe 2-wire White
Ceiling PC2WLA-E Horn/Strobe 2-wire White
Ceiling, English PC2WLA-F Horn/Strobe 2-wire White
Ceiling, French SCRL SCRLA* Strobe Red Ceiling
SCRLA-E* Strobe Red Ceiling, English SCRLA-F Strobe Red Ceiling, French
SCWL SCWLA* Strobe White Ceiling SCWLA-E Strobe White Ceiling, English SCWLA-F Strobe White Ceiling, French
SCWL-CLR-
ALERT
— Stobe White Ceiling Clear Lens Alert
SRL SRLA* Strobe Red Wall SRLA-E Strobe Red Wall, English SRLA-F Strobe Red Wall, French
SRL-P SRLA-P Strobe Red Wall, Plain SRL-SP — Strobe Red Wall, Fuego SWL SWLA* Strobe White Wall
SWLA-E Strobe White Wall, English SWLA-F Strobe White Wall, French
SWL-ALERT — Strobe White Wall, Amber Lens
SWL-CLR-
ALERT
— Strobe White Wall, Clear Lens
SWL-P SWLA-P Strobe White Wall, Plain
*Bilingual Canadian model †Add suffix “E” for English, “-F” for French, and “-P” for plain version (no text).
Compatible Equipment Note: ULC-listed models have all required languages.
3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495
©2019 System Sensor.
Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.
SPDS902-01 • 7/29/2020
System Sensor® and SWIFT® are registered trademarks of Honeywell International, Inc.
Duracell® is a registered trademark of Duracell U.S. Operations Inc.
Panasonic® is a registered trademark of Panasonic Corporation.
Ordering Information Part No. Description WAV-CRL Wireless AV base, ceiling, red WAV-CWL Wireless AV base, ceiling, white WAV-RL* Wireless AV base, wall, red WAV-WL* Wireless AV base, wall, white W-SYNC Wireless Sync Module W-BATCART Wireless battery cartridge, 10-pack *Note: WAV-RL & WAV-WL are compatible with wall-mount L-Series devices manufactured after 26 April 2019 (date code 9045 and later). WAV-CRL and WAV-CWL are compatible with all ceiling-mount L-Series devices.
Accessories
W-BATCART
Wireless battery cartridge
SPDS902-01 • 7/29/2020 • Page 1
The SWIFT AV bases (WAV-CRL, WAV-CWL, WAV-RL and WAV-WL) are intended for use with compatible System Sensor L-Series AV notification appliances to meet a comprehensive range of notification requirements. The AV Base provides power for the audio and visual signals and supports wireless communication with the Fire Alarm Control Panel (FACP). The L-Series AV notification appliance is mounted directly to the wireless AV base allowing flexibility in color, placement and signal output.
Power is supplied through two sets of 4 batteries – one set provides power for wireless communication, and the other set provides power for the notification appliance’s audio and/or visual signal. Battery life of the wireless portion is UL listed for at least 2 years. Battery life for the AV set of batteries depends upon the activation time and output level of the audio or visual signal. The AV base boosts output voltage to support 24VDC options on connected devices.
The SWIFT synchronization module (W-SYNC) can be used to provide audio and visual synchronization between SWIFT notification appliances and System Sensor wired notification appliances. The wireless synchronization module operates from 24V power with supplemental battery support and communicates through the mesh network to the gateway and FACP. Synchronization is only available with notification appliances that use the System Sensor synchronization protocol. Synchronization of the SWIFT notification appliances within a single mesh network is inherent in the wireless system and a wireless synchronization module is not needed.
The W-SYNC also provides wireless control and monitoring of a Notification Appliance Circuit (NAC) expander or power supply.
SWIFT SYSTEM OVERVIEW
The SWIFT Smart Wireless Integrated Fire Technology wireless system offers intelligent (addressable) devices which provide secure, reliable communication to the Fire Alarm Control Panel (FACP) across a Class A mesh network. Wireless devices create an opportunity for applications where it is costly (concrete walls/ceilings, buried wires), obtrusive (surface mount conduit), or possibly dangerous
Features
• Wireless installation
• Class A mesh network
• Addressable code wheels
• Commercial applications
• Listed to UL 464, UL 1638, UL 1971, ULC S525, and ULC S526
• Frequency hopping
• Bi-Directional Communications
SWIFT AV Base
The System Sensor SWIFT® Wireless system offers an AV base to support L-Series devices in wireless installations.
Agency Listings
7300-1653:0513S4011 3062564
SPDS902-01 • 7/29/2020 • Page 2
Specifications Physical/Operating Specifications
Dimensions (Ceiling) Diameter 7.4” (19 cm); Depth 1.6” (4 cm) Weight (Ceiling): 20.0 oz (567 g) installed with 8 batteries Dimensions (Wall) Height 6” (15 cm); Width 5.1” (13 cm); Depth 1.6” (4 cm) Weight (Wall) 17.6 oz (499 g) installed with 8 batteries
Electrical Specifications
RF Operating Voltage Range 3.3 VDC RF Maximum Current Draw 5 mA (LED On) RF Operating Voltage 12 VDC AV Output, Operating Voltage 24 VDC (nominal) AV Maximum Standby Current 6.5 mA AV Maximum Alarm Current 550 mA Standby Current 210 µA @ 3.3 VDC (LED blink enabled) Maximum Transmit RF Power 17 dBm Radio Frequency Range 902-928 MHz Operating Humidity Range 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range 32°F to 120°F (0°C to 49°C) Battery Type 8 Panasonic CR123A or 8 Duracell DL123A Battery Life RF batteries: 2 year minimum.
AV batteries: See Table 2 for AV battery life.
Battery Replacement Replace during annual maintenance or when TROUBLE BATTERY LOW displays.
AV Battery Life at Temporal 3, Ambient Conditions
Model Model Type
Battery Life (Hour, Minutes), per Candela Setting 15 cd 30 cd 75 cd 95 cd 110 cd 115 cd 135 cd 150 cd 177 cd 185 cd
Chime-only Wall 127h 23m — — — — — — — — — Ceiling — — — — — — — — — —
Horn-only Wall 31h 51m — — — — — — — — — Ceiling — — — — — — — — — —
Strobe-only Wall 20h 44m 14h 09m 8h 20m 7h 22m 6h 02m — 5h 11m — — 4h 01m Ceiling 21h 45m 14h 09m 8h 02m 6h 39m — 5h 39m — 4h 43m 3h 57m —
Chime-Strobe Wall 18h 12m 12h 55m 7h 58m 6h 31m 5h 18m — 4h 26m — — 3h 37m Ceiling 18h 35m 12h 44m 7h 41m 6h 28m — 5h 24m — 4h 29m 3h 45m —
Horn-Strobe Wall 16h 31m 12h 03m 7h 22m 6h 17m 5h 30m — 4h 33m — — 3h 38m Ceiling 12h 34m 9h 54m 6h 14m 5h 24m — 4h 46m — 4h 07m 3h 31m —
Low-Freq.
Sounder-Only
Wall 8h 15m — — — — — — — — — — Ceiling 8h 15m — — — — — — — — — —
Low-Freq.
Sounder- Strobe
Wall — 9h 6m 7h 45m 5h 39m 4h 56m 4h 54m - 4h 12m — — 3h 18m
NOTE: Battery life will decrease using continuous tone or other coded patterns and under non-ambient environmental conditions.
(asbestos) to use traditional wired devices. It allows fast installation for time-critical situations and provides the flexibility to add wireless onto wired systems for retrofit installations. Both wired and wireless devices can be present on the same FACP for an integrated solution.
The mesh network within the SWIFT system creates a child-parent relationship between the devices so that each device has two parents providing a second path for communications on every device. If one device can no longer operate for any reason, the rest of the devices can still communicate with each other, directly or through one or more intermediate devices. Once an initial mesh network is formed, mesh restructuring automatically occurs to find the strongest paths possible within the network.
The SWIFT system also engages frequency hopping to prevent system interference whether intentional or accidental. Each device complies with part 15 of the FCC rules: 1) The device may not cause harmful interference and 2) The device must accept any interference received including interference that may cause undesired operation.
SPDS902-01 • 7/29/2020 • Page 3
Model (UL listed)
Model (ULC listed) Description
CHRL CHRLA* Chime Red Wall CHSCRL CHSCRLA* Chime/Strobe Red Ceiling
CHSCRLA-E Chime/Strobe Red Ceiling, English
CHSCRLA-F Chime/Strobe Red Ceiling, French
CHSCWL CHSCWLA* Chime Strobe White Ceiling CHSCWLA-E Chime/Strobe White Ceiling, English CHSCWLA-F Chime/Strobe White Ceiling, French CHSRL CHSRLA* Chime Strobe Red Wall
CHSRLA-E Chime/Strobe Red Wall, English
CHSRLA-F Chime/Strobe Red Wall, French
CHSWL CHSWLA Chime Strobe White Wall CHSWLA-E Chime/Strobe White Wall, English CHSWLA-F Chime/Strobe White Wall, French CHWL CHWLA Chime White Wall HCRL-LF HCRLA-LF† 520Hz Sounder Red Ceiling HRL HRLA Horn Red Wall HRL-LF HRLA-LF† 520Hz Sounder Red Wall HCWL-LF HCWLA-LF† 520Hz Sounder White Ceiling HWL HWLA Horn White Wall HWL-LF HWLA-LF† 520Hz Sounder White Wall P2RL P2RLA* Horn/Strobe 2-wire Red Wall
P2RLA-E Horn/Strobe 2-wire Red Wall, English
P2RLA-F Horn/Strobe 2-wire Red Wall, French
P2RL-LF P2RLA-LF† 520Hz Sounder/Strobe Red Wall
P2RL-P P2RLA-P Horn Strobe 2-wire Red Wall, Plain
P2RL-SP — Horn Strobe 2-wire Red Wall, Fuego
P2WL P2WLA Horn Strobe 2-wire White Wall P2WLA-E Horn/Strobe 2-wire White Wall, English P2WLA-F Horn/Strobe 2-wire White Wall, French
Model (UL listed)
Model (ULC listed) Description
P2WL-LF P2WLA-LF† 520Hz Sounder/Strobe White Wall
P2WL-P P2WLA-P Horn Strobe 2-wire White Wall, Plain
P2WL-SP — Horn Strobe 2-wire White Wall, Fuego
PC2RL PC2RLA* Horn Strobe 2-wire Red Ceiling PC2RLA-E Horn/Strobe 2-wire Red
Ceiling, English PC2RLA-F Horn/Strobe 2-wire Red
Ceiling, French PC2WL PC2WLA* Horn Strobe 2-wire White
Ceiling PC2WLA-E Horn/Strobe 2-wire White
Ceiling, English PC2WLA-F Horn/Strobe 2-wire White
Ceiling, French SCRL SCRLA* Strobe Red Ceiling
SCRLA-E* Strobe Red Ceiling, English SCRLA-F Strobe Red Ceiling, French
SCWL SCWLA* Strobe White Ceiling SCWLA-E Strobe White Ceiling, English SCWLA-F Strobe White Ceiling, French
SCWL-CLR-
ALERT
— Stobe White Ceiling Clear Lens Alert
SRL SRLA* Strobe Red Wall SRLA-E Strobe Red Wall, English SRLA-F Strobe Red Wall, French
SRL-P SRLA-P Strobe Red Wall, Plain SRL-SP — Strobe Red Wall, Fuego SWL SWLA* Strobe White Wall
SWLA-E Strobe White Wall, English SWLA-F Strobe White Wall, French
SWL-ALERT — Strobe White Wall, Amber Lens
SWL-CLR-
ALERT
— Strobe White Wall, Clear Lens
SWL-P SWLA-P Strobe White Wall, Plain
*Bilingual Canadian model †Add suffix “E” for English, “-F” for French, and “-P” for plain version (no text).
Compatible Equipment Note: ULC-listed models have all required languages.
3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495
©2019 System Sensor.
Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.
SPDS902-01 • 7/29/2020
System Sensor® and SWIFT® are registered trademarks of Honeywell International, Inc.
Duracell® is a registered trademark of Duracell U.S. Operations Inc.
Panasonic® is a registered trademark of Panasonic Corporation.
Ordering Information Part No. Description WAV-CRL Wireless AV base, ceiling, red WAV-CWL Wireless AV base, ceiling, white WAV-RL* Wireless AV base, wall, red WAV-WL* Wireless AV base, wall, white W-SYNC Wireless Sync Module W-BATCART Wireless battery cartridge, 10-pack *Note: WAV-RL & WAV-WL are compatible with wall-mount L-Series devices manufactured after 26 April 2019 (date code 9045 and later). WAV-CRL and WAV-CWL are compatible with all ceiling-mount L-Series devices.
Accessories
W-BATCART
Wireless battery cartridge
HORNS & SOUNDERS
SpectrAlert® Advance Outdoor Horn
SpectrAlert® Advance Series horns are designed to simplify installations to provide primary and secondary signaling for fire and security applications.
Overview
The SpectrAlert® Advance outdoor horns increase application flexibility for outdoor installations. Intended for full building notification as well as on the property ground, they produce a loud sound to notify occupants to evacuate the buildings.
Installers can easily adapt devices to suit a wide range of application requirements by using field-selectable sound patterns and volume settings. Compatible with 12- or 24-volt systems. The universal mounting plate's plug-in design simplifies installation.
Synchronization is also provided when using the MDL module.
Features & Benefits:
12 and 24V operation
Rotary switch for horn tone and three volume selections
Temporal and non-temporal tones
Horn rated at 88+ dBA at 16 volts
Rated from -40 degrees to 151 degrees F, with NEMA 4X rating
Tamper-resistant construction
Listing for ceiling or wall-mounting
Certifications:
UL Listed S4011
ULC Listed
FM Approved 3023572
MEA Approved MEA452-05-E
CSFM Listing 7135-1653:189
Specifications Brand : Farenhyt|Gamewell-FCI|NOTIFIER|System Sensor
Fe ed ba ck
Product Type : Horn
HRK
Horn: Red: Outdoor: Plastic Weatherproof Backbox
HRK-R
Horn: Red: Outdoor: Plastic Weatherproof Backbox: Replacement
HRKA
Horn, Red, Outdoor, Plastic Weatherproof Backbox, ULC Listed
Fe ed ba ck https://buildings.honeywell.com/pif/cwa/oauth/request/j_security_check?resource=https://buildings.honeywell.com/us/en/products/by-category/fire-life-safety/notification-appliances/horns-and-sounders/spectralert-advance-outdoor-horn?pdpPageTab=pills-sku-tab&appId=78
Intelligent Wireless
WAM-MM & WAM-RC
SWIFT Wireless Modules
WAM-RC Wireless Relay Module
WAM-MM Wireless Monitor Module
The SWIFT® wireless monitor module is intended for use with a wireless gateway to interface with a device having contacts used to signal status conditions. It is designed to provide an interface to contact devices such as security contacts, waterflow switches, or pull stations. The input to the monitor module is non-latching and does not require a reset. The device has a panel controlled LED indicator. The monitor module must be within 3-feet of the monitored device when using field wiring or 20 feet in non-metallic conduit.
The SWIFT wireless relay module allows the control panel to switch contacts by code command. The relay contains an isolated set of Form-C contacts, which operate as a
SPDT switch. Circuit connections to the relay are not supervised by the module. The
SWIFT relay module can be used to activate functions such as a remote power supply
(in conjunction with a monitor module), elevator recall, door holders and fan shutdown of wired devices or SWIFT devices within the same mesh network. The module also includes a panel-controlled LED indicator.
The devices communicate across the mesh network through a gateway to the FACP.
The FACP views the SWIFT wireless device and another addressable device on the system providing similar detection functions and outputs as a wired counterpart. In addition, both wired and wireless devices can be present on the same FACP to meet the needs of a given application. A SWIFT wireless system can use any combination of modules, smoke, or heat detectors.
SWIFT wireless modules are intelligent (addressable) modules which provide secure, reliable communication to the Fire Alarm Control Panel (FACP) across a Class A mesh network. Wireless modules create an opportunity for applications where it is costly
(concrete walls/ceilings, buried wires), obtrusive (surface mount conduit), or possibly dangerous (asbestos) to use traditional wired devices. In addition, both wired and wireless devices can be present on the same FACP providing an integrated wired-wireless solution for increased installation potential.
The mesh network within the SWIFT system creates a child-parent relationship between the devices so that each device has two parents providing a second path for communications on every device. If one device can no longer operate for any reason, the rest of the devices can still communicate with each other, directly or through one or more intermediate devices.
The SWIFT system also engages frequency hopping to prevent system interference whether intentional or accidental.
FEATURES & BENEFITS
• Wireless installation
• Class A mesh network
• Addressable code wheels
• Commercial applications
• UL 268 listed
• Frequency hopping • Bi-directional communications
Page 2 of 3 — 9021-60819:F • 10/3/2018
Compatible Control Panels
• 7075 Series
• S3 Series
• E3 Series
SWIFT Components and Ordering Information
• WAM-MM: Wireless monitor module. Used to monitor devices with mechanical contact actuation. Includes a special cover with a built-in tamper magnet. Recommended for installation in a SMB500-
WH box (ordered separately) rather than a metal backbox for best performance. Requires (4) CR-123A batteries (included).
• WAM-RC: Wireless relay module for use with the VW-GATE wireless gateway. Includes a special cover with a built-in tamper magnet.
Recommended for installation in an SMB500-WH box (ordered separately) rather than a metal backbox for best performance.
Requires (4) CR-123A batteries (included).
• VW-GATE: Wireless SWIFT Gateway - 1 SWIFT Gateway is required for each wireless mesh, and supports up to 48 SWIFT detectors or modules, and one display driver, if required. Connects to the SLC loop of a compatible panel using Velociti protocol. Power may be supplied by the SLC circuit or via an optional 24VDC input.
Note: Use of the 24VDC input may be more convenient for service as it allows for powering down a gateway without shutting down an SLC loop.
• VW-DIS-D: LCD user interface for use with the VW-GATE wireless gateway and an GFANN-80 Remote Annunciator. Connects to the
FACP via the ANN-BUS. Both VW-DIS-D and GFANN-80 are required to display trouble and supervisory conditions that are specific to the VW-GATE and its devices. One VW-DIS-D is required for each VW-GATE in a system using the E3 or S3 control panel.
• GFANN-80: White 80 character LCD annunciator used with the
VW-DIS-D to display wireless-specific events not displayed on the
FACP.
• WSD-P: Intelligent, wireless photo detector. Requires one B210W base for installation. Requires (4) CR-123A batteries (included).
• WSD-ACCLIMATE: Intelligent wireless Acclimate® heat and photo detector using combined heat and smoke sensor information and the ability to automatically adjust sensitivity based on ambient changes in the environment. Requires one B210W base for installation. Requires (4) CR-123A batteries (included).
• WTD-RH: Intelligent wireless rate of rise (135°) heat detector.
Requires one B210W base for installation. Requires (4) CR-123A batteries (included).
• WTD-H: Intelligent wireless fixed-temperature (135°) heat detector. Requires one B210W base for installation. Requires (4)
CR-123A batteries (included).
• WPS-DL: Wireless addressable pullstation. Requires (4) CR-123A batteries (included).
• WAV-CRL, WAV-CWL: SWIFT Wireless Addressable A/V bases.
Requires (8) CR-123A batteries (included). Requires a non-compact ceiling System Sensor® L-series notification device
(ordered separately).
• W-SYNC: Wireless sync module. Requires (4) CR-123A batteries
(included).
• SMB500-WH: Optional surface-mount backbox.
• B210W: Detector base used for wireless detectors. Includes a built-in magnet so that wireless devices can establish installed and tampered states.
• SWIFT Tools: Programming and diagnostic utility. Free download from www.gamewell-fci.com. For installation on a (typically laptop)
PC running an approved version of Windows (See Minimum
System Requirements for SWIFT Tools). Requires the W-USB radio/ antenna dongle for communication with SWIFT Wireless devices.
• W-USB: Wireless USB radio/antenna dongle that plugs into the
USB port of a PC running SWIFT Tools. The W-USB provides a communication link with SWIFT Wireless devices.
• W-BATCART: Wireless battery cartridge, 10-pack. For use with wireless pullstations and A/V bases.
WAM-MM & WAM-RC Technical Specifications
9021-60819 | F | 10/18 ©2018 Honeywell International Inc.
Acclimate® Plus, E3 Series®, Gamewell-FCI®, SWIFT®, System Sensor®, and Velociti® are registered trademarks of Honeywell International Inc.
Microsoft® and Windows® are registered trademarks of Microsoft Corporation.
Duracell® is a registered trademark of Duracell U.S.
Operations Inc. Panasonic® is a registered trademark of Panasonic Corporation.
©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.
This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
Country of origin: Mexico
Honeywell Gamewell-FCI 12 Clintonville Road
Northford, CT 06472-1610
203.484.7161 www.gamewell-fci.com
MONITOR MODULE
Physical / Operating
Dimensions: Height 4-1/2 inches; Width 4-1/2 inches;
Depth 1-1/2 inches Device Weight (includes 4 batteries): 7.9 oz (224 g) Operating Temperature Range: 32°F to 120°F (0°C to 49°C) Operating Humidity Range: 10% to 93% non-condensing
Electrical
EOL Resistance: 3.9K Ohms Maximum IDC Wiring Resistance: 10 Ohms Maximum IDC Voltage: 3.2 Volts Maximum Average IDC Current: 5.5µA Maximum Transmit RF Power: 17 dBm Radio Frequency Range: 902-928 MHz
Battery
Battery Type: 4 Panasonic® CR123A or 4 Duracell® DL 123A Battery Life: 2 years Battery Replacement: Upon BATTERY LOW or BAT LOW display and/or during annual maintenance
RELAY MODULE
Physical / Operating
Dimensions: Height 4-1/4 inches; Width 4-1/4 inches;
Depth 1-1/2 inches Operating Temperature Range: 32°F to 120°F (0°C to 49°C) Operating Humidity Range: 10% to 93% non-condensing
Electrical
Maximum Transmit RF Power: 17 dBm Radio Frequency Range: 902-928 MHz
Battery
Battery Type: 4 Panasonic® CR123A or 4 Duracell® DL 123A Battery Life: 2 years Battery Replacement: Upon BATTERY LOW or BAT LOW display and/or during annual maintenance
RELAY CONTACT RATINGS
AGENCY LISTINGS AND APPROVALS
Each device complies with part 15 of the FCC rules meaning operation is subject to two conditions.
1) The device may not cause harmful interference and 2) The device must accept any interference received including interference that may cause undesired operation.
The listings and approvals below apply to the basic intelligent wireless detectors. In some cases, certain modules may not be listed by certain approval agencies or listing may be in process. Consult factory for latest listing status.
UL Listed: S1949 CSFM: (Monitor Module): 7300-1703:0181;
(Relay module): 7300-1703:0185 FM Approved
FDFCC ID: (Monitor Module) AUBWFSMM and (Relay Module) AUBWFSRM
STANDARDS AND CODES
The SWIFT Wireless Intelligent Detectors comply with the following UL Standards and with NFPA 72 Fire Alarm System requirements.
UL 864
UL 268
CURRENT
RATING
MAXIMUM
VOLTAGE
LOAD
DESCRIPTION
APPLICATION
2 A 25 VAC PF = 0.35 Non-coded
3 A 30 VDC Resistive Non-coded
2 A 30 VDC Resistive Coded
0.46 A 30 VDC (L/R = 20ms) Non-coded
0.7 A 70.7 VAC PF = 0.35 Non-coded
0.9 A 125 VDC Resistive Non-coded
0.5 A 125 VAC PF = 0.75 Non-coded
0.3 A 125 VAC PF = 0.35 Non-coded
COMBINATION STROBES
L-Series 2-Wire Wall Horn Strobe
L-Series 2-wire horn strobes include a variety of features that increase their application versatility while simplifying installation.
Overview
The L-Series line of wall horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the backbox, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults.
To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12 or 24V operation, and a rotary switch for horn tones with two volume selections.
Features & Benefits:
Updated modern aesthetics
Small (Compact) profile devices for Horns and Horn Strobes
Plug-in design with minimal intrusion into the backbox
Tamper-resistant construction
Automatic selection of 12- or 24-volt operation at 15 and 30 candela
Field-selectable candela settings for wall units: 15, 30, 75, 95, 110, 135, and 185.
Horn rated at 88+ dBA at 16 volts
Rotary switch for horn tone and two volume selections
Mounting plate for all standard and all compact wall units
Mounting plate shorting spring checks wiring continuity before device installation
Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices
Compatible with MDL3 sync module
Certifications:
UL Listed: S4011- S5512
ULC Listed: S4011- S5512
Fe ed ba ck
FM Approved
CSFM: 7125-1653:0504- 7135-1653:0503
Specifications
Product Number
Brand : Farenhyt|Gamewell-FCI|NOTIFIER|System Sensor
Mounting Type : Wall
Product Type : Horn Strobe
P2RL-BP10
Horn Strobe: 2-wire: Indoor: Wall: Red: Bulk Pack: Marked FIRE
P2WL-P
Horn Strobe, 2-wire, Indoor, Wall, White, Plain (ECSMNS applicable)
P2WL-SP
Horn Strobe, 2-wire, Indoor, Wall, White, Marked FUEGO
Honeywell will provide product support until March 2030 Discontinued ed ba https://buildings.honeywell.com/pif/cwa/oauth/request/j_security_check?resource=https://buildings.honeywell.com/us/en/products/by-category/fire-life-safety/notification-appliances/combination-strobes/l-series-2-wire-wall-horn-strobe?pdpPageTab=pills-sku-tab&appId=78
MONITOR MODULES
Addressable Dual Monitor Module
The Gamewell-FCI Velocity® Series, Addressable Dual Monitor Module features two Style B, Class B initiating device circuits, each with an end-of-line resistor.
Overview
The Gamewell-FCI Velocity® Series, Addressable Dual Monitor Module features two Style B, Class B initiating device circuits, each with an end-of-line resistor. This module provides addresses for any device or group of devices connected to each circuit.
Any alarm initiating devices with…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .